Loading...
HomeMy WebLinkAboutREVISION BUILDING PERMITOFFICE USE ONLY: DATE FILED: lCI (➢' / PERMIT# REVISION FEE: RECEIPT# i Y PLANNING & DEVELOPMENT SERVICES SCANNED BUILDING & CODE REGULATION DIVISION BY -- 2300 VIRGINIA AVENUE St. Lucie County FORT PIERCE, FL 34982-5652 (772)462.1553 APPLICATION FOR BUILDING PERISION PROJECT INFORMATION MMMMMMIIIIII LOCATION/SITE ADDRESS: -703 &GeO 4un.. DETAILED DESCRIPTION OF PROJECT CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: BUSINESS NAME: efe QUALIFIERS NAME: ADDRESS: ,25r74 yyie YGp , CITY: r-t Pleza- STATE: PHONE (DAYTIME): �7Z - �jilYi _ 3ro OWNER/BUILDER INFORMATION: AN - ST. LUCIE CO CERT. #: at 1de- _ ZIP: FAX: �7>- �L�y CITY: STATE: PHONE (DAYTIME: FAX: ARCHITECT/ENGINEER INFORMATION: I ADDRESS: CITY: STATE: PHONE (DAYTIME): FE SLCCC:9123109 Revised 06130117 ke ZIP: DEC 16 2019 department St._wde County, FL ,A FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION „ Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: DOYLE SPEC Builder Name: Street: 1703 PASEO AVENUE Permit Office: ST LUCIE COUNTY city, State, Zip: FORT PIERCE, FL, Permit Number: Owner. Jurisdiction: ST LUCIE COUNTY Design Location:_ FL, Fort. Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1471.0 sqft.) Insulation Area 2. Single family or multiple family Single-family• a. Concrete Block- Polystyrene Bead AggreR=0.o 1471.00 ft' b. N/A R= ft- 3. Number of units, if multiple family 1 c. N/A R= tt2 4. Number of Bedrooms 3 d. N/A R= ft' 10. Ceiling Types (1751.0 sgft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 1751.00 ft2 6. Conditioned floor area above grade (ft-) 1751 b. N/A R= ft- Conditioned floor area below grade (ft') 0 c. N/A R= ft- 11. Ducts R ft- 7. Windows(96.0 sqft.) Description Area a,Sup: Aftic, Ret: Aftic, AH: AHU CLST 6 150 a. U-Factor. Sgl, U=0.31 84.00 ft' SHGC: SHGC=0.28 b. U-Factor. Sgl, U=0.30 12.00 ft- 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a. Central Unit 35.2 SEER:16.00 c. U-Factor: N/A ft' SHGC: 13. Heating systems kBtumr Efficiency d. U-Factor: N/A fta. Electric Strip Heat 27.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 2oD0 ft. Area Weighted Average SHGC: 0.285 14. Hot water systems a. Electric Tankless Cap: 1 gallons 8. Floor Types (1751.0 sqft.) Insulation Area EF: 0.990 a. Slab -On -Grade Edge Insulation R=0.0 1751.00 ft' b. Conservation features b. N/A R= ft' None c. N/A R= ft' 15. Credits None Glass/Floor Area: 0.055 Total Proposed Modified Loads: 54.56 PASS Total Baseline Loads: 54.87 1 hereby certify that the plans and specifications covered by Review of the plans and TOE SrAl this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. nn'••..`=..GN=,0 PREPAR D Y: Before construction is completed DATE: l this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy C COO WE ttt0 OWNER/AGENT BUILDING OFFICIAL: DATE: DATE: 1 - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 10e-pt15 11-117),1 Ra FILE COPY 11/6/201911:02AM Etlge� U 021cev 1) - R121 ,�F 6NEn(2017) Compliant Software Page 1 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: DOYLE SPEC Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1751 Lot# Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook + Builder Name: Rotate Angle: 0 Street: 1703 PASEO AVENUE Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE v Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1751 14725 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 LAUNDRY 112 896 No 0 1 Yes Yes Yes 2 KITCHEN 238 2142 Yes 0 1 Yes Yes Yes 3 M BATH 124 992 No 0 1 Yes Yes Yes 4 M W IC 2 48 384 No 0 1 No Yes Yes 5 AHU CLST 9 72 No 0 1 No Yes Yes 6 BATH 2 51 408 No 0 1 No Yes Yes 7 MASTER BEDROO 240 1920 No 0 1 1 Yes Yes Yes 8 M WIC 1 42 336 No 0 1 Yes Yes Yes 9 HALLWAY 88 704 No 0 1 No Yes Yes 10 LINEN 8 64 No 0 1 No Yes Yes 11 BEDROOM 2 144 1152 No 0 1 1 Yes Yes Yes 12 CLST 3 12 96 No 0 1 No Yes Yes 13 CLST 2 12 96 No 0 1 Yes Yes Yes 14 BEDROOM 3 144 1152 No 0 1 1 Yes Yes Yes 15 LIVING ROOM 479 4311 No 0 1 Yes Yes Yes FLOORS' # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation LAUNDRY 22 ft 0 112 ft- -- 1 0 0 2 Slab -On -Grade Edge Insulation KITCHEN 17 ft 0 238 ft' — 1 0 0 38Iab-OnGrade Edge Insulation M BATH 16 ft 0 124 ft' — 1 0 0 11161201911:02 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 48Iab-OnGrade Edge Insulation M WIC 2 t It 0 48 ft- — 1 0 0 58Iab-OnGrade Edge Insulation AHU CLST 1 It 0 9 ft' _ 1 0 0 6Slab-OnGrade Edge Insulation BATH 2 1 It 0 51 ft' — 1 0 0 7Slab-OnGrade Edge Insulation MASTER BEDRO 31 ft 0 240 ft- — 1 0 0 BSIab-OnGrade Edge Insulation M WIC 1 6 It 0 42 ft- — 1 0 0 9SIab-On-Grade Edge Insulation HALLWAY 1 ft 0 88 ft' — 1 0 0 10SIab-On-Grade Edge Insulation LINEN 1 It 0 8 ft' — 1 0 0 118Iab-OnGrade Edge Insulation BEDROOM 2 24 It 0 144 ft' — 1 0 0 1251ab-OnGrade Edge Insulation CLST 3 1 It 0 12 ft- — 1 0 0 1381ab-OnGrade Edge Insulation CLST 2 2 it 0 12 ft' -- 1 0 0 14SIab-OnGrade Edge Insulation BEDROOM 3 12 It 0 144 ft' -- 1 0 0 1551ab-OnGrade Edge Insulation LIVING ROOM 46 H 0 479 ft' — 1 0 0 ROOF / Roof Gable Roof Red Solar SA Emitt Emilt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1958 ft' Oft' Light N 0.6 No 0.9 No 0 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1751 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attie (Vented) LAUNDRY 30 Blom 112 ft- 0.1 Wood _ 2 Under Attic (Vented) KITCHEN 30 Blown 238 ft' 0.1 Wood 3 Under Attic (Vented) M BATH 30 Blown 124 ft' 0.1 Wood 4 Under Aftic(Vented) MWIC2 30 Blown 48 ft- 0.1 Wood 5 Under Attic (Vented) AHU CLST 30 Blown 9ft' 0.1 Wood _ 6 Under Attic (Vented) BATH 2 30 Blown 51 ft' 0.1 Wood 7 Under Attic (Vented) MASTER BEDRO 30 Blown 240 ft' 0.1 Wood _ 8 Under Attic (Vented) M WIC 1 30 Blown 42 ft' 0.1 Wood _ 9 Under Attic (Vented) HALLWAY 30 Blown 68 ft' 0.1 Wood _ 10 Under Attic (Vented) LINEN 30 Blown 8ft' 0.1 Wood 11 Under Attie (Vented) BEDROOM 30 Blown 144 ft' 0.1 Wood 12 Under Attic (Vented) CLST 3 30 Blown 12 ft- 0.1 Wood _ 13 Under Attic (Vented) CLST 2 30 Blown 12 ft- 0.1 Wood 14 Under Attic (Vented) BEDROOM 30 Blown 144ft' 0.1 Wood 15 Under Attic (Vented) LIVING ROOM 30 Blown 479 ft' 0.1 Wood 11/6/201911:02 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 E Exterior Concrete Block- Polystyrdt4UNDRY 0 14 0 8 0 112.0 ft- 0 0 0.6 0 2 S Exterior Concrete Block- Polystyretr@UN DRY 0 8 0 8 0 64.0 ft- 0 0 0.6 0 3 S Exterior Concrete Block- PolystyredfdaTCHEN 0 17 0 9 0 153.0 ft' 0 0 0.6 0 4 E Exterior Concrete Block- Polystyrerfd BATH 0 2 0 8 0 16.0 ft' 0 0 0.6 0 _5 S_ .Exterior Concrete Block - Polystyrerfd BATH 0 12 0 8 0 96.0 fF 0 0 0.6 0 _ 6 W Exterior Concrete Block - Polystyrertd BATH 0 2 0 8 0 16.0 ft- 0 0 0.6 0 _ 7 S Exterior Concrete Block - PolystyddMTER BE 0 15 0 8 0 120.0 ft' 0 0 0.6 0 _ 8 W Exterior Concrete Block- Polystydd*STER BE 0 16 0 8 0 128.0 ft' 0 0 0.6 0 9 W Exterior Concrete Block- PolystyrerM WIC 1 0 6 0 8 0 48.0 fN 0 0 0.6 0 _ 10 N Exterior Concrete Block- Polysty&BmROOM 2 0 12 0 8 0 96.0 ft' 0 0 0.6 0 _ 11 W Exterior Concrete Block - PolystyMDROOM 2 0 12 0 8 0 96.0 W 0 0 0.6 0 12 N Exterior Concrete Block - PolystyrenSLST 2 0 2 0 8 0 16.0 ft- 0 0 0.6 0 _ 13 N Exterior Concrete Block- PdystyEbOROOM 3 0 12 0 8 0 96.0 fF 0 0 0.6 0 _ 14 N Exterior Concrete Block- PolystyddWNG ROO 0 26 0 9 0 234.0 ftf 0 0 0.6 0 15 E Exterior Concrete Block- PolystyddWNG ROO 0 20 0 9 0 180.0 ft' 0 0 0.6 0 DOORS # Omt Door Type Space Stones U-Value Width Height Area Ft In Ft In 1 E Insulated LAUNDRY None .39 2 8 6 8 17.8ft- 2 N Insulated LIVING ROO None .39 3 6 8 20 ft' WINDOWS Orientation shown is the entered Proposed orientation. / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 S 3 Vinyl Low-E Single Yes 0.31 0.28 Y 9.0 fP 2 ft 0 in 1 ft 4 in None None 2 S 5 Vinyl Low-E Single Yes 0.3 0.32 Y 12.0 ft' 2 it 0 in 1 ft 4 in None None 3 S 7 Vinyl Low-E Single Yes 0.31 0.28 Y 15.0 ft- 2 R 0 in 1 ft 4 in None None 4 N 10 Vinyl Low-E Single Yes 0.31 0.28 Y 15.0 ft' 2 it 0 in 1 ft 4 in None None 5 N 13 Vinyl Low-E Single Yes 0.31 0.28 Y 15.0 ft' 2 ft 0 in 1 ft 4 in None None 6 N 14 Vinyl Low-E Single Yes 0.31 0.28 Y 30.0 ft' 2 it 0 in 1 ft 4 in None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000374 1717.9 94.31 177.37 .1322 7 11161201911:02 AM EnergyGaugeG USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPA 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER: 16 35.2 kBtu/hr 1056 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric Tankless Exterior 0.99 1 gal 55.1 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None W DUCTS _ / —Supply— --Return Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 150 ft' Attic 15 ft' Default Leakage AHU CLST (Default) c(Default) c 1 1 TEMPERATURES Programable Thermostateat[:Cool!ng CApreiling Fans: Jan[X]1N Feb[Feb[Xj] Mar[I Venting ]] MMay[[X]1 [[X]1 �Xj Aug 4X]] [[ ]] f[X]] ([X�] Dec Jan [ ] Feb [X] Mar [XJ Apr [ ] MaDec y [ ] Jun [ ] Jul [ ] Sep [X] Oct [X] Nov [ ] Dec Thermostat Schedule: HERS 2006 Reference - Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (VVEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. Oft' Oft 0.3 LAUNDRY Default(8lbs/sq.ft. fP ft 0.3 KITCHEN Defauk(8lbs/sq.ft. fl' ft 0.3 M BATH Default(8 lbs/sq.ft. ft' it 0.3 M WIC 2 DefauR(8lbs/sq.ft. fP ft 0.3 AHU CLST ' Default(S lbs/sq.ft. ft* ft 0.3 BATH 2 DefauR(B lbs/sq.ft. ft. It 0.3 MASTER BEDROO DefauR(8lbs/sq.ft. ft' ft 0.3 M WIC 1 11/6I201911:02 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Fumiture Fraction Space Default(61bs/sq.ft. ft' It 0.3 HALLWAY Default(8 lbs/sq.ft. ft' ft 0.3 LINEN DefauH(8 lbs/sq.ft. ft- ft 0.3 BEDROOM 2 Default(8 lbs/sq.ft. fl' ft 0.3 CLST 3 Default(8 lbs/sq.ft. fN ft 0.3 CLST 2 Defautt(8lbs/sq.ft. f? ft 0.3 BEDROOM 3 Default(8lbs/s .ft. ft' it 0.3 LIVING ROOM 11/6/201911:02 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: DOYLE SPEC Builder Name: Street: 1703 PASEO AVENUE Permit Office: STLUCIECOUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Y U Owner. Jurisdiction: ST LUCIE COUNTY W x Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop dawn stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope Insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity Insulation shall be Installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walks Exposed earth in umented crawl spaces shall be covered with a Where provided instead of floor insulation, Insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walks. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures Installed in the building thermal envelope shall Recessed light fixtures Installed in the building be sealed to the drywall. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring a plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior wails boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -Floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. a. In addition, Inspection of log walls shall be in accordance with the provisions of ICC-400. 11/61201911:03 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lowerthe Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location& insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location AHU CLST 3. No, of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 5. Is this a worst case? (yes/no) 5. No 6. Conditioned floor area (sq. ft.) 6. 1751 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.309 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.285 c) Area 7c. 96.0 8. Skylights a) U-factor:(weighted average) Be. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 91b. c) Concrete, raised (R-value) 9c. 10. Wall type and insulation: A Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent. 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 10A1. 10A2. 0.0 13. Cooling system: Capacity 35.2 a) Split system SEER 16.0 b) Single package SEER c) Ground/water source SEER/COP d) Room unit/PTAC EER e) Other 14. Heating system: Capacity 27.0 a) Split system heat pump HSPF b) Single package heat pump HSPF c) Electric resistance COP 1.0 d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE f) Other 15. Water heating system a) Electric resistance EF 0.99 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF_ f) Heat recovery unit HeatRec9/o g) Other 10B1. 10132. 16. HVAC credits claimed (Performance Method) a) Ceiling fans 11a. 30.0 b) Cross ventilation No 11b. c) Whole house fan No 11c. d) Multizone cooling credit 11 d. No e) Multizone heating credit f) Programmable thermostat No `Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. f, Builder Signature: Date: Address of New Home: 1703 PASEO AVENUE City/FL Zip: FORT PIERCE, FL 11/6/201911:03:39 AM EnergyGaugeO USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1