BLOWER DON TE.5T IFORM
House InfiBtrration Vest Certification
Prescri(ative and Performonce Method
772-288-2139 p.1
e `l,UY
DEC -3 2019
Permitting E)e'partment
St. Lucie County, FL
Date: i tiL-�-i LQ Permit9: j 4 0 G- 0 1 3`i4
Contractor:
.lob Address
���elviv�L�
BY
St. Lucie County
l ec C, i �. t —�%iY-exe2. ��6✓v e�e.✓�` �O
SI I o 07 -- I N . 1. a._ V Fr_ 3`FYY2
Construction: } New Construction — Cornpiete ( } Eristing—After Addition
House Infiltration Test Results SLC Climate Zone 2
CFM (e)= l d 6 i Test Date: _ - t ti�
Volume = 13 .1 S" 2-
ACH (50) = CFM (50) It Go / Volume =. L�. , Il9echanical Ven211ation required less than 3 CH
Passing results muss be c$ ACH (50) or less 6A Pass ( ) Pail
else, energy
The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per
hour in Climate Zone 1, 2 and 3 air changes per hour In Climate Zones 3 through 8. Testingshall be conducted with a
blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in
Section 553.S93(5) or (7), Florida Statutes or individuals licensed asset forth in Section 489.105 (3)(f), (g) or (i) or an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to the code official. Testing shall be performed at anytime after creation of all penetrations of the building
thermal envelope.
SEC, Residential
Where the air Infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a
pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Cade, Energy Conservation
the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
Testing Company
Company Name: Pro-D00t Services
Address: 1915 Rio Vista Drive, Ft Pierce, FL 34949
I hereby certify that the above House Infiltration results demonstrate compliance uvith FBC Energy Conservation
requirements in accordance with Section R402.4.1.2 Climate Zone 2.
Signature:
Printed Name: Martin Klein
License/Certification#: 5061633