Loading...
HomeMy WebLinkAboutTRUSS PLAN"WARNING* -THIS IS A PLACEMENT PLAN FOR ENGINEERED COMPONENTS AS DEFINED BY WTCA 1 - 1995. ALL BEARING POINTS MUST BE IDIAPHRAMS HAVE NOT BEEN ANALYZED BY INSTALLED PRIOR TO INSTALLING ANY EAST COAST TRUSS. -FOR ERECTION AND INSTALLATION OF TRUSSES TRUSSES! FAILURE TO DO SO MAY RESULT IN FOLLOW INSTRUCTIONS ON THE BCSI-B1 SUMMARY DAMAGED TRUSSES AND WILL VOID ALL WARRANTIES. SHEETS AND SEALED ENGINEERED TRUSS DRAWINGS 1) FOR THE ERECTION BRACING FOLLOW NSTRUCTIONS ON THE BCSI-B1 SUMMARY SHEETS 2) PERMANENT BRACING FOR THE STRUCTURE IS HE RESPONSIBILITY OF OTHERS. 3) INSTALL WEB BRACING AS STATED ON SEALED NGINEERING TRUSS DRAWINGS. STRUCTURAL DATA, NUMBER OF GIRDER AND TRUSS PLIES AND THE CONNECTION INFORMATION. OUR DESIGN DEPARTMENT MUST APPROVE ALTERATIONS AND/OR REPAIRS TO TRUSSES IN ADVANCE. DESIGN DEPARTMENT APPROVES THEM IN ADVANCE ALL HANGERS ARE SIMPSON STRONG -TIE UNLESS OTHERWISE NOTED. INSTALL HANGERS ACCORDING TO THE CURRENT SIMPSON STRONG -TIE CATALOG 8'-0" PLATE HT. 1Y 10'-8" PLATE HT. HARDWARE: =HUS26 HANGERS (QTY. 6) -TH026-2 HANGERS (QTY. 1) Indicates Left End Of Truss Can Layout & Engineering S_, heets 4 3/16" 1'4" 758" RECEIVED JUN 06 2019 ST. Lucie County, Permitting PAUL WELCH INC. MECH-ELECT-ClVN ENG 198481 ST. 9114 PAUL WELLCM P E FLLA �G 29M MAY 1 0 2019 12 6F-- ENGINEERED TIMBER TRUSS SYSTEMS PRODUCTS ECT ]EASE' COAST TRUSS 5285 ST. LUCIE BLVD. FT. PIERCE. FL 34946 OFFICE: (772) 466-2480 FAX: (772)466-5336 CUSTOMER:Hometech Contractors JOB NAME: 1553 Model ADDRESS:5110 Birch Dr. CITY/COUNTY:Ft. Pierce/St. Lucie JOB # J37732 File Copy JOB # MODEL:Custom SQ FT 2221 DATE 04/25/19 (LATEST=/ / 61GISS-31.003 (3) (e), EAST COAST TRUSS is the "Truss NO, Engineer" Trusses are designed in aeecrd.uen with the Florida Building Code NOTE: By approving this placement plan(s), signatured anywhere on this sheet, the customer or his representitive acknowledges that this placement plan complies with the structural intent of the project. The customer also acknowledges that this approval authorizes EAST COAST TRUSS to manufacture these trusses and deliver them to the project indicated on this drawing. The customer also acknowledges that he/she accepts financial responsibility for any repair, engineering, and labor required due to errors other than those of EAST COAST TRUSS. Signed: Date: ODE = FBC 2017/TP12014 ASCE 7-10 ESIGN CRITERIA =MWFRS CCUPANCY CATEGORY=11 XPOSURE = B WF SPEED =170 UILDING TYPE =ENCLOSED EAN HEIGHT: 15.00 L FLOOR: DUR FACTOR= 1.0 PSF=TCLL-TCDL-BCLL-BCDL 40.0110-010.075.0 OF: DUR FACTOR= 1.25 F=TCLL-TC D L-B C L L-BCD L 20.0,15.0,0.0110.0 LOADS PER FBC & FR( "NON -CONCURRENT BC LL 10psf CONCURRENT BC STORAGE LL 20 psf DEFINITIONS MWF = MAIN WIND FORCE C&C = COMPONENTS AND CLADDING TOB = TOP OF BEARING TIC = TOP CHORD BC = BOTTOM CHORD LL = LIVE LOAD DL = DEAD LOAD psf = POUNDS PER SQUARE FOOT # =POUNDS UPLIFT MUST BY-PASS FLOOR TRUSSES UNLESS SHOWN ON ENGINEERED TRUSS DRAWING. ALL GIRDER/COLUMN LOADS MUST BY-PASS FLOOR TRUSS UNLESS SHOWN ON ENGINEERED TRUSS DRAWING. RECOMMENDED ON FLOOR TRUSSES SPANNING 201-0" OR MORE T BE SET WITH A SPREADER BAR. THE EADER BAR SHOULD BE AT LEAST 1/2 IN LENGTH AS THE SPAN OF THE TRUSS ING SET. R TO BCI-B1 FOR COMPLETE TION AND SAFETY PROCEDURES. SUPPORT ANY PLANT SHELVES 1- 2- 3- 5- SCANNF 6 St. Luce County A i i i a Z LL U) W Z E) 17) LU (n LU 0 L11 U) I— O Z H S J H TRUSS PLACEMENT PLAN (1/4" if plotted 24x36) . Designed By: SB