Loading...
HomeMy WebLinkAboutDESIGN - WIND LOAD COMPLIANCEDEPARTMENT OF COMMUNITY DEVELOPMEW err VIRGINIA AVENUE,ROOM 201 Fr. PIERCE, FL 34982-56M .. :r -1553 DESIGN CERTIFICATION FOR WIND LOAD COMPLIANCE, 1 ? This Certification Is to be completed by the project design architect or engineer. This Certification must be submitted with all applications for buying permit Invohring the construction of new residence (single or multi -family), residential addition. arty accessory structure requiring a building permit, and any nonresidential stricture. This Certification shall not apply to interior renovations (provided that no stnrdural walls, columns or other similar component Is being effected)_and certain other mirror balding permits. For further assistance, please contact the Building Inspection Office at 462-IM or 462-2172 PROJECT NAME C: FZ S fv %!!SE Dfilz w STREET ADDRESS ' �' PR NUMBER V 0,t F C. PERMIT NUMBER .. OCCP. TYPE CST.TYPE CERTIFICATION STATEMENT: I CERTIFY THAT, TO THE BEST OF MY KNOWLEDGE AND BELIEF, THESE PLANS AND SPECIFICATIONS HAVE BEEN DESIGNED TO COMPLY WITH THE APPLICABLE STRUCTURAL PORTION OF THE BUILDING CODES CURRENTLY ADOPTED AND ENFORCED BY ST. LUCIE COUNTY. I ALSO CERTIFY THAT STRUCTURAL ELEMENTS DEPICTED ON THESE PLANS PROVIDE ADEQUATE RESISTANCE TO THE WIND LOADS AND FORCES SPECIFIED BY CURRENT CODE PROVISIONS. DESIGN PARAMETERS AND ASSUMPTIONS USED: release check or complete the appropriate box) 1. BUILDING CODE EDITION USED (YEAR) r r r 7 SBCCI ASCE 7-88 OTHER (SPECIFY) ?. BUILDING DESIGN IS (ctEcK ow ENCLOSED PARTIALLY ENCLOSED OPEN BUILDING 3. BUILDING HEIGHT- FT 4. WIND SPEED USED IN BUILDING DESIGN: MPH 5. WIND EXPOSURE CLASSIFICATION (REFHt m opmw YAai CG IN mx=NG eocE IoENrrFlm IN uNE st): 8. AVERAGE WIND VELOCITY PRESSURE ON EXTERIOR FACES' OF STRUCTURE 2$. PSF Z. PEAK WIND VELOCITY PRESSURE ON EXTERIOR FACES OF STRUCTURE - PSF e. IMPORTANCEIUSE FACTOR (oarAIN FROM mx=NG coDE? 9. LOADS: FLOOR 100 PSF ROOFIDEAD: ) 2- - PSF ROOFAJVE: 3 S Pw 10. WERE SHEAR WALLS CONSIDERED FOR STRUCTURE (crECK ow) YES V NO _ If NO, why? (atlach explanation) IS A CONTINUOUS LOAD PATH PROVIDED (c EDK oW YES ✓ NO _ If NO, why? (eearJf Ir' explanation) FIF: 12 ARE COMPONENT AND CLADDING DETAILS PROVIDED (OC-CK ow YES NO _ B NO, why? (attach explanation) 1]. MINIMUM SOIL BEARING PRESSURE PSF AS WITNESSED BY MY SEAL, I HEREBY CERTIFY THAT THE INFORMATION INCLUDED WITH THIS CERTIFICATION IS TRUE AND CORRECT. TO THE BEST OF MY KNOWLEDGE AND BELIE NAME: JP C7 . j C W-- 4�:- CERTIFICATION NO: �/ 0 [SEAL HERE] FIRM: DATE: L� 2 — rG '—'V