HomeMy WebLinkAboutTRUSS PAPERWORK4451 ST. LUCIE BLVD FORT PIERCE, FL 34946 PH: 772-409-1010 FX: 772-409-1015 www.AlTruss.com AI ORIClr°';t�ii�VM I 1 V}�\Y TRUSS ENGINEERING' BUILDER: RENAR PROJECT: MORNINGSIDE COUNTY. ST LUCIE LOT/BLK/MODEL: LOT:115 / MODEL:CAYMAN 1560 / ELEV.B1/ GAR R JOB#: 76597 MASTER#: WRMSCM1560B1L j OPTIONS: 16X9 PORCH. NO VALLEYS. i A-1 ROOF TRUSSES A FLORIDA CORPORATION RE: Job WRMSCM1560131L Site Information: Lumber design values are in accordance with ANSI/TPI 1-2014 section 6.3 These truss designs rely on lumber values established by others. A-1 Roof Trusses 4451 St Lucie Blvd Fort Pierce, FL 34946 Customer Info: RENAR DEVELOPMENT CO. Project Name: MORNINGSIDE Lot/Block: 115 Model: CAYMAN_ 1560 Address: 320 PALM BREEZE DRIVE Subdivision: City: County: St Lucie State: FL Name Address and License # of Structural Engineer of Record, If there is one, for the building. Name: License #: Address: City: General Truss Engineering Criteria Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2017ITP12014 Design Program: MiTek 20/20 8.2 Wind Code: ASCE 7-10 Wind Speed: 160 Roof Load: 37.0 psf Floor Load: 0.0 psf This package includes 42 individual, dated Truss Design Drawings and 16 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms. to 61G15-31.003,section 5 of the Florida Board of Professional Engineers Rules. No. Seal # Truss Name Date No. Seal # Truss Name Date No. Seal # 'i Truss Name Date 1 A0209266 A01 2/21/19 13 A0209278 A13 2121/19 25 A0209290 CJ5 2/21/19 2 A0209267 A02 2121/19 14 A0209279 A14G 2121119 26 A0209291 CJ5A 2/21/19 3 A0209268 A03 2/21/19 15 A0209280 B01G 2121/19 27 A0209292 CJ5C 2/21/19 4 A0209269 A04 2121/19 16 A0209281 B02 2/21119 28 A0209293 CJ5L 2121119 5 A0209270 A05 2/21/19 17 A0209282 B03 2/21/19 29 A0209294 CJ6 2/21/19 6 A0209271 A06 2/21/19 18 IA0209283 B04G 2/21/19 30 A0209295 HJ7 2/21119 7 A0209272 A07 2121/19 19 IA0209284 B05 2/21/19 31 A0209296 HJ7A 2/21/19 8 A0209273 A08 2121119 20 A0209285 B06 2/21119 32 A0209297 HJ7L 2/21/19 9 A0209274 A09 2121/19 21 A0209286 CJ1 2/21/19 33 A0209298 J7 2121/19 10 A0209275 A10 2121/19 22 A0209287 CJ3 2/21/19 34 A0209299 J71. 2/21119 11 A0209276 All 2121/19 23 A0209288 g 2121/19 35 A0209300 RT 2/21/19 12 IA0209277 I Al2 2/21/19 24 A0209289 I CJ3L 2121/19 J136 IA0209301 T06 2/21/19 is tuaa u,cwn u(e) iciuc, ticu i wvc ueen µups txi oy,vii ieK amusui s, =.under Truss Design Engineer's Name: Anthony Tombo III My license renewal date for the state of Florida is February 28,2021. NOTE:Theseal on these drawings indicate acceptance of pmfessionalmginmring responslbUirty solelyforthe truss components shown. ale parameters pravldeo byP l Koot I msses, Lid. The suitabilityand use of componentsforany padicularbuilding lathe responsibility of the building designer, perANSIIrPI.1 Sec, 2. The Truss Design Drawing(s)(TDD[s]) referenced haw: been prepared based on the construction documents (also referred to at times as Structural Engineering Documentsl provided by the Building Designer indicating the nature and rharacterofthe work. The design criteria therein have been transferred to AnthonyTombo m PE by [All Roof Trusses orspecific location]. These TDDs (also referred to at times m Structural Delegated Engineering Dowmentsl are specialty structural component designs and maybe part of the pmject's deferred orphased submittals. As a Truss Design Engineer(ie,specially Engineei),the seal here and on the TDD represents an acceptance of professional engineering Anthony T. responsibility forthe design of the single Truss depicted on the TDD only. The Building Designeris responsible forand shall coordinate and review, the TDDs for compatibility with thebwfltten engineering requ'sements. Please review all TDDs and all related notes. 4d3bb9d9999eZ0ab10bcdeBe Page 1 of 2 �- A-1 ROOF TRUSSES AFLOROACORPORATION RE: Job WRMSCM1560BlL No. Seal # Truss Name Date 37 A0209302 T06A 2121/19 38 A0209303 T06SGE 2/21119 39 A0209304 VM08 2/21/19 40 A0209305 VM10 2121/19 41 A0209306 VM12 2121/19 42 A0209307 VM14 2/21/19 43 STDL01 STD. DETAIL 2/21/19 44 STDL02 STD. DETAIL 2/21/19 45 STDL03 STD. DETAIL 2/21119 46 STOL04 STD. DETAIL 2121119 47 STDL05 STD. DETAIL 2/21/19 48 STDL06 STD. DETAIL 2121/19 49 STDL07 STD. DETAIL 2121/19 50 STDL08 STD. DETAIL 2121/19 51 STDL09 STD. DETAIL 2/21/19 52 STDL10 STD. DETAIL 2/21/19 53 STDL11 STD. DETAIL 2/21119 54 - STDL12 STD. DETAIL 2121/19 55 STDL13 STD. DETAIL 2121/19 56 STDL14 STD. DETAIL 2121/19 57 STDL15 STD. DETAIL 2/21/19 58 STDL16 STD. DETAIL 2/21/19 Lumber design values are in accordance with ANSI/TPI 1-2014 section 6.3 These truss designs rely on lumber values established by others. Page 2 of 2 o russ toss ype ty y A0209266 WRMSCM158081L A01 Roo(Spedal 1 1 ,lob Reference o tional A-1 a001I msses, ton coerce, rL sasao, oesigntgaluuss.conn k A-4-0 7-4-0 7x10 MT20HS-, 3><6 = 2x4'II 6.00 12 5x6 C 2.4 11 7 a 7x10 MT20HS- 22 21 1s 17 - 15 3.6 = 4.6 = &4 It 2x4 II 4x8 = 3x8 = 1.5x4 11 3.6 7-24-0 1IT II-2 17-44 19-1-� 24-0-0 30-10-12 38-0.0 7-4-0 7-21-9-5 5-2-10 6-6-12 7-1d Dead Load Deli. =1/21n Plate Offsets (X Y)-- r4:0-3-0,Edgel f6:0-3-00-3-01 r7:0-M Ednel 110:0-8-0 0-2-e1 111:0-3-0 Edgel rl7:0-2-12 0-1-121 f19:0-5-8 0.3-81 120:0-3-80-2-121 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.91 Vart(LL) 0.53 18 >854 360 MT20 244I190 TCDL 10.0 Lumber OOL 1.25 BC 0.96 Vert(CT) -1.0119-20 >452 240 MT20HS 1871143 BCLL 0.0 ' Rep Stress Incr YES WB 1.00 Horz(CT) 0.58 13 We n/a BCDL 7.0 Code FBC20171TPI2014 Matrix -MS Weight:2241b' FT=10% LUMBER - TOP CHORD 2x4 SP No.2'ExcepY T3: 2x4 SP M 30 BOTCHORD 2x4 SP No.2 `Except' B2,B4: 2x4 SP No.3 WEBS 2x4 SP No.3'Except' W3: 2x4 SP No.2, W6:2x4 SP M 30 BRACING- TOPCHORD Structural wood sheathing directly applied or 2-0-14 oc pudins. BOTCHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 1 Row at micipt 10-17 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 149010-7-10 (min. 0-1-12) 13 = 149010-7-10 (min. 0-1-12) Max Horz 2 = -138(LC 10) Max Uplift 2 = -377(LC 12) 13 = -430(LC 13) Max Grav 2 = 1490(LC 1) 13 = 1490(LC 1) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 23=-2664/1666, 3-4=-4163/2474, 4-5=-4061/2489, 5-6=4033/2514, 7-8=-254/176, 6-8=564613203, 8-9=-5890/3353, 9-10=-5842/3342, 10-11 =-I 997/1402, 11-12=2105/1392, 12-13=-2688/1678, 6-7=-270/191 BOTCHORD 2-22=1303/2308. 19-20=-1752/3602, 9-19=-296/266, 16-17=-133812336, 15-16=1338/2336, 13-15=133812336 WEBS 3-22=1339/845, 20-22=-1523/2709, WEBS 3-22=-1339/845, 20-22=-1523/2709, 6-19=1278/2608, 17-19=-1134/2387, 10-17=1262/578, 12-17=-619/549, 6-20=335/499, 3-20=-559/1368, 10-19=2209/4464 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. II; Exp B; Encl., GCpl=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber D01=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads. 6)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 377 Ito uplift at joint and 430 lb uplift at joint 13. 8) Graphical pudin representation does not depict the size or the orientation of the pudin along the top anti/or bottom chord. LOAD CASE(S) Standard edvtltiqb¢�eoe1 m Hnlagl(1IflaR11I.npr11nAuC4f 1eYlW9 k Iltll.IZubMO.b^mR9kt d1'.4Rul ID1anbetlbbr4bADO0bbp14 rN1%4OWF40rteP.ldm'hmcmbrobsS mdumblmun netlmrlmBovMtrMfisp d5003a lb hVAwdn mhd aOkmlAnubye%H1al Anthony T. Tef1160III, P.E. rrludla MsbemfkY9khntlauxarema,m.haminbbtlW ebk101En4=.vd�0db0.NKbIW 4d1aY4nL,rI Mt 1N9Ane�tlm Nimw6JmdmlmvWY91>Te4m9,.bA9S eJhKgilSkbmiu8lryd a80083 h MdglnlmtlreWi!.3Ca¢,mlWeh46ed6lmM,olPddaedb, CtllgtulmvShlf4vmaT4jpltrdelhamiVJmMueafblmnlp4ax mlCiutiee�mfemnWmndtaum Aape.lmlMgtyaaeil,mrMrJe,aw 44515t. Lucie Blvd. tlaMulfatlNlr�mW lWba2ghelmnptlrtL hlmvbuPfquub101hrMgkpee,¢imvfl0a6pmam:aq aq%latl�o•nbxibmt � fort Pierce,F. 34946 (vppi1607nIM11vvtlnuo-Am1vgl.IwdvlO.Pi lepndeNvvddivdvmvem,ovglwv,npml2uedxibvNlAr edtnvpanvisdvvhvvkl bdinsus-AtlEvvrLlvvly N, P3. Job Truss I russ ype lyPly A0200267 WRMSCM1560BIL A02 Hip 1 1 Job Reference o tional A-1 Roof Trusses, Fort Pierce, FL 34946, design(o1BMSSMI1 6.00 12 US = Pvb II 2.4 11 axis = 20 le 10 1O m 3x6 = 46 = 2x4 II 2x4 II 5.8 = 3.6 = 34 1.5x4 It 7-4-0 11-11-2 73-0 I 4-7-2 I -019-1-fi 2I 2-9-3--1388-8-0--20-0 6144 A- Dead Load Deb. = 7116 in Plate Offsets (X Y)— t6:0-3-0 0-2-01 18:0-6-0 0-2-81 f15:0-2-8 0-2-01 117:0-2-0 0-3-8] 118:038 0-2-121 LOADING(psf) SPACING- 2-M CSI. DEFL. in (loc) Udell L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.99 Vert(LL) -0.41 17-18 >999 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 - - BC 0.89 Vert(CT) -0.81 17-18 >562 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.80 Horz(CT) 0.48 11 n1a n/a BCDL 7.0 Code FBC2017/1-PI2014 Matdx-MS Weighl:2211b FT=10% LUMBER - TOP CHORD 2x4 SP No.2 BOTCHORD 2x4 SP N0.2'Excepr B2,B4: 2x4 SP No.3 WEBS 2x4 SP No.3 *Except* W3,W7,W6: 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied. BOTCHORD Rigid ceiling directly applied or4-7-15 oc bracing. WEBS 1 Row at midpt 8-15, 10-15 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation quids. REACTIONS. (lb/size) 2 = 1490/0-7-10 (min. 0-1-12) 11 = 1490/0-7-10 (min.0-1-12) Max Hoe 2 = -139(LC 10) Max Uplift 2 = -378(LC 12) 11 = -378(LC 13) Max Grav 2 = 1490(LC 1) 11 = 1490(LC 1) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-2664/1664, 3-4=-4164/2474, 4-5=AO62/2489, 5-6=-4171/2629, 6-7=-4081/2370, 7-8=-4045/2360, 8-9=-1836/1336,9-10=-1948/1312, 10-11=261211629 BOTCHORD 2-20=-1301/2307,5-18=-224/270,. 17-18=-145513218,14-15=-1266/2250, 13-14=-1266/2250,11-13=-1266/2250 WEBS 3-20=-13361841, 18-20=-151612704, 6-18=-746/926, 6-17=561/1302, 15-17=-130912960, 8-15=-2068/846, 10-15=718/630, 10-13=01300, WEBS 3-20=1336/841, 18-20=-151612704, 6-18=-746/926, 6-17=561/1302, 15-17=-1309/2960, 8-15=20681846, 10-15=718/630, 10-13=0/300, 3-18=564/1371, 8-17=-1604/3565 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. II; Ezp B; End., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and farces & MWFRS for reactions shown; Lumber DOL=1.60 plate gdp DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads. 5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 378 Ib uplift at joint 2 and 378 Ib uplift at joint 11. LOAD CASE(S) Standard canmmn<mNtryme.m•urxrsm52Mlate[rasuuluAc�emn¢[mrarimrrwcs�urrl.m rnhao?i.mwmmRsam.mlaumsmo.rv(INvdNwrt.e�arf�ewav,Rmt me�,m.msea.Nmlwr WteY<mwibrddfNwd4ibn6mNNl AsekwpoNhy¢e(N.$nr%LhvdwoiMrtPrsrmcvryaseRbiMsr3!v4mdAerNNksmdtruyVmlynduOeaAm¢mdAL 4eP.ti@w4ti�m:bdqurflNn.oui� Anthony T. Telnho In, P.E. Wm did imsb gNYbisbmj'k,dhMm.h bese dgdubhmgWga,mhoNdtlNm.heCdbMW'%hmdmi.bype,vliblmdabuofdbW'Wddgbft MlpleNOSvetltrnkilAbtl .Wddoli Ca0083 N w'N,m d enure. 90W..&= dN pnmsmpwvenNrmmruepmsrz7urnmapmiµWaNh mwswextlum4bp,npa,a io-1in, Dead 4451 St. Lurie Blvd. sa.Nldvdhlrrvm'd9^b^-,4 a Nms ATeTnuhuphpw uea hhYyiagn,uNu hnmbpm d'W' in'Mmbmmmddndmfil. Fort Pierce, FL 34946 /(/(/////.�■•���\\\\\\ � (vhiigh®1➢IAAI Pvvlimues-AIDIavrLrvmlvlil, P.E Ivpndvdivedtdisdummem,ivverh�m,ispmd3nedriRvmmerdbapeimisLmhem A-1 fledimssmAvlEvvrt.lemlo0l, Pl {� ro b Truss I was I ype ry y WRMSCMI6l10BiL A03 Hip 1 1 A02092fi8 Job Reference o fienal n-, nurn cusses, ron rm,m, ra . ii4b, oeagn(,a a,wss.wm nun: 8.2W s May 18 2018 Prod 8.210 s May 18 2018 MTek Industries, Ina Thu Feb 21 14:44:46 2019 Page 1 ID:Id_0OXyyT61Bi_TXoliwHHzefvK-iOgijOWIMA-4?dXkimi5yODbaV4aNYtN1 hXIMZziurF a 2pd-0 11-11-2 174W 1&1 29.10-12 3680 9d -]-2 5-87 t4 156 86.12 &1d 1 1.2-10 6.00 12 5x10 % 5x6 20 19 75 14 - 12 4u6 = 2x4 II = 3z6 = 3x4 I I 3x6 = US 6.6 = 20-0 0 7-4-0 11-11-z 176 19.1 2a10-12 36P0 ]be I 0-7-2 56-14 136 86.12 I 9-03 1-2-10 Dead Lead Defl. = 5116 in 0 v 4g Plate Offsets (X Y)- 14:0-3-0 Edge] (7:0-M 0-1-81 112:0-3-0 0-2-01 116:0-2-8 0-3-01 (18'0-5-4 Edeel LOADING(psf) SPACING- 2-041 CSI. DEFL. in (too) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL. 1.25 TC 0.80 Vert(LL) -0.33 15 >999 360 MT20 2441190 TCDL 10.0 Lumber DOL 1.25 BC 0.91 Vert(CT) -0.60 17-18 >765 240 SCLL 0.0 Rep Stress Incr YES WS 0.97 Horz(CT) 0.40 10 n/a n/a BCDL 7.0 Code FBC20177TPI2014 Matrix -MS Weight:2211b FT=10% LUMBER - TOP CHORD 2x4 SP 240OF 2.0E *Except' T3: 2x4 SP No.2 BOTCHORD 2x4 SP No.2 *Except' B2: 2x4 SP No.3 WEBS 2x4 SP No.3 *Except' W3: 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc puriins. BOTCHORD Rigid ceiling direc0y applied or 4-2-6 oc bracing. Except: 10-0-0 oc bracing: 14-16 WEBS 1 Row at midpt 12-16 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 149710-7-10 (min. 0-1-12) 10 = 149810-7-10 (min. 0-1-12) Max Horz 2 = -156(LC 10) Max Uplift 2 = 367(LC 12) 10 = -387(LC 13) Max Gmv 2 = 1497(LC 1) 10 = 1498(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOP CHORD 2-3=-2674/1670, 34=4231/2526, 4-5=-4123/2541, 5-6=3329/1912, 6-7=-3331/1979, 7-8=3683/2093, 8-9=-3815/2064, 9-10=-2617/1630 BOTCHORD 2-20=-1306/2317, 5-18=-206/367, 17-18=-1998/3877, 16-17=-1221/2990, 10-12=1266/2256, 7-16=-042/1337 WEBS 3-20=-1354/854,18-20=-1524/2714, 5-17=8911794, 6-17=363/566, WEBS 3-20=-13541854, 18-20=-1524/2714, 5-17=-891/794, 6-17=363/566, 6-16=-3417795, 9-16=-10311041, 9-12=-1088/759,12-16=-1453/2556, 3-18=-613/1427 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. It: Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water pending. 4) This truss has been designed for a 10.0 psf bottom chord live load noncencurrent with any other live loads. 5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 7.Opsf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 387 lb uplift at joint 2 and 387 lb uplift at joint 10. LOAD CASE(S) Standard Ymhg.! CvnllJ1,nmb'IAnCi4fifa(itllaAgtAi1[III�lfM:11MlS(61]q(9n4'I I;II[gt6�Ytlll'Im teYlkoily Jmol Jrans¢,irmEeghwq{IW!tlmlGm/i.IxM4gFWme9z,IVnrse.Iblm, Ae.a Ctl,aalC4aj wrn«=a�ln,�xraaamoaaw..t,.un:®mp4pmm{u.y ryue:„mssaomtm o. .,aar+ mwr*gny�umlmmAngvam�rxu.nemmtlnmtw.p.m:nl. manpwePra..`argmewsssup Anthony T. Tombo 111, P.E. tlned4,la,aWie4Lyhmmlmffiim!ea0+,v.mo+ei:rBsLtlyv9ablaYagonrys.rh�weuda IN.aCmimbmkxagMem441.1bp{mJdaIDadg64ueabimsehSgkYyM@.4AffivmlhrEl Yflhmnyo�ary,f 260083 ' rwegougnmraasm.mmxmmem4mdalm+esmpm3,lmpaag0m"smclea<•vemOslpsmmktnmstuwmumeapmipam;r uumv,amlmnus:lmeeaus,eenyr.tm,4,�g�uga7mtn„amomn,em, 44515t. Lucie Blvd. w.iv(cagr.l�+rmtleme.mylr,mrrmaa,n tataun:yF,to„eute.annoy:..u.nttnrmn,mem,op mommmgmmvameaanml. � Fort pierce, FL 34946 (vppigb®POIAAi Anlhvsses-AmEvept.ivmlvi4P.E lrpwdeoivv Alhisivmmem,ieverfvmispnh3dedWtlEvmlEevmnvpe,missieo6om1�l lvdrnsseo-AvOvvri.rvmlvlll,Pi Job Truss NssType ly y A0209269 WRMSCM156OBlL A04 ROOFSPECIAL 3 1 +� Job Reference (olAbonalft A-1 Roof Trusses, Fort Pierce, FL 34946. design@altn ss.00m 1 7-2-1 12-11-12 19-0-0 25-0-0 31 9-15 35.0.0 -0- 7-2-7 59-11 fi41-4 6-0-0 5-9-11 7-2.1 6.00 12 5x6 = Dead Laatl Deg. = 9/16 in 5 5x6 O 5x6 4 6 1.5x4 W 3 1.5x4 i 3 7 - - 12 1 6xa = B 14 13 11 0 1 v 1 2 3x8 MT20HS% 3x8 MT20 19 ro 0 3x4 3.00 12 3x4 - 1.5g45114 I I 1 1.5x4 II 1.5x4 II 5x8 48 1.5x4 II 5x8 // 30-9-15 9-104 19U0 27-141 28-1-12 36 9-164 --1 &142 -31 &1�-0-62-a 6 Plate Offsets (X Y)- I2'0-1-14 Edcel I4'0-3-0 0-3-0] f6'0-3-0 0-3-01 I8'0-4-7,Edoe1 I8.0-40 0-0-121 f8'0-2-1 Edoel LOADING(psf) SPACING- 2-M CSI. DEFL. in (loc) I/deft Lid PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.71 Vert(LL) 0.5512-14 >826 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.84 Vert(CT) -1.0412-14 >437 240 MT20HS 1871143 BCLL 0.0 • Rep Stress Incr YES WB 0.91 Horz(CT) 0.65 8 We n/a BCDL 7.0 Code FBC2017/TPI2014 Matrix-MSH Weight: 200 lb FT=10% LUMBER - TOP CHORD 2x4 SP No.2 *Except* T1: 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 *Except* W6,W5:2x4 SP No.2 WEDGE Left: 2x4 SP No.3, Right: 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 2-2-0 oc pudins. BOT CHORD Rigid ceiling directly applied or 4-6-12 oc bmcing. Except: 4-7-0 oc bracing: 8-10 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 1490/0-7-10 (min.0-1-11) 8 = 1490/0-7-10 (min.0-1-11) Max Horz 2 = 166(LC 11) Max Uplift 2 = -399(LC 12) 8 = -399(LC 13) Max Grav 2 = 1490(LC 1) 8 = 1490(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-4697/2907, 3-4=-4307/2635, 4-5=-3134/1852, 5-6=-3134/1852, 6-7=-4321/2660, 7-8=-4676/2926 BOTCHORD 2-14=2490/4232, 13-14=-1906/3619, 12-13=-190213644, 11-12=1905/3647, 10-11=191613622, 8-10=-2507/4245 WEBS 5-12=-1338/2394, 6-12=-864/801, 6-10=285/576, 7-10=352/445, WEBS 5-12=1338/2394, 6-12=-864/801, 6-10=285/576, 7-10=-352/445, 4-12=-861/196, 4-14=-280/568, 3-14=356/464 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ¢ This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 2, 8 considers parallel to grain value using ANSVTPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 399 lb uplift at joint 2 and 399 lb uplift at joint 8. LOAD CASE(S) Standard 4�u1 awlm0.h - ar-1IIW:06, Nfet'JCIAn6�luY'Vir�WICn.9elf11-bra 4eAth"TPUYmd J,MeartmaM91KV4 ¢aloffi ll.bmme4Mitseex vlesrEMnbNmhlN.uj bs4kfL WlaamorMNPNmImmtM!§kai nvki�6J¢apikmW9(4 Yu8nvlNCmmmt¢e¢�a6Mytln�Crle2vnu9nW'�YtivtYminaamsejcirtlgAtlnmrtBup.dvll4L lals'mmngnrtf.YipmRnyvmlkl AsfI mDuoE AnttlonYT. III, P.E. vAneawin beSxYebnmmw>mremawemo.ai':.a¢ad4znamYmSon�m.vbemnamm.bLmmioNNf39MImiRthmYnalammvd,naumamimcN�rkt4 mnebmvummhe§�ba¢ Ma 80083 '.L k Rxglmih,br® 16t'mllaWglllsCWlnrzmem0kpntlptiv¢R.IMmNrryvaOtleps¢d6fna@zbnsGmyn.Ime0n4bF¢¢�laa [aWanahss ¢Ihl�NT..Ilfla cle 4d515t.WCe WM .W,l, 11 'U10W.ill1pKncm ,bmvldetllre4emryMep Ymnyhe. rvmzmamt hlmuk:grgm.I,Yo5IhlaYylcPn ab�ulrYmFgkmavrmlEg NmD'sam9anmaei3rr1eIM11. rron Pierce,R 349d6 3494 (vhiilH®1vIAAi aAimssve-AmCvepLimme111,1.E &pmduaiveollhisdvmmem,iv vgfei4ispm6ilihdvi@vNlM1evnneepe�ssiuhvm A -I pvALasn Ak wrT.L hffl,P1. o a mss cuss ypa y y WRMSCMiSgOBiL A05 SCISSORS A0209270 4 1 Job Reference otional • 1-4-0 1.5x4 6.00 12 5x6 = 5x8 9 Sx8 1 6 12 6x8 = 14 13 11 10 US MT20HS� 3x8 MT20HS; 3x4 � 3.00 12 3x4 c Feb 2114'" 482019 Pagel pJyTJoOrTFgU?OSRSziurD Dead Load Dell. = 9116 In 1.5x4 7 N + a 89 0 4.8 4x8 = 9-8-74 19-0-0 2832 38-0-0 9-8-14 932 9-3 32 9-8-14 Plate Offsets (X Y)- 12:0-1-14 Edcel 14:0-3-12 0-3-01 16:0-3-12 0-3-01 L&0-1-14 Edeel LOADING(psf) SPACING- 2-M CSI. DEFL. in (loc) I/defl Lid PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.71 Vert(L-) 0.58 12-14 >789 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.83 Vert(CT) -1.08 12-14 >420 240 MT20HS 187/143 BCLL 0.0 ' Rep Stress Incr YES WB 0.92 Horz(CT) 0.69 8 We n/a BCDL 7.0 Code FBC2017/TP12014 Matrix -MS Weight:180lb FT=10% LUMBER - TOP CHORD 2x4 SP N0.2 *Except* T1: 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3, Right: 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 2-2-0 oc pudins. BOTCHORD Rigid ceiling directly applied or4-5-14 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 1490/0-7-10 (min. 0-1-11) 8 = 149010-7-10 (min. 0-1-11) Max Horz 2 = -166(LC 10) Max Uplift 2 = -399(LC 12) 8 = -399(LC 13) Max Grav 2 = 1490(LC 1) 8 = 1490(LC 1) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-4730/2950, 3-4=-4291/2612, 4-5=-3137/1854, 5-6=-3137/1854, 6-7=-4291/2626, 7-8=-4730/2972 BOT CHORD 2-14=2537/4265, 13-14=191613626, 12-13=1912/3651, 11-12=191713651, 10-11=-1921/3626, 8-10=-2560/4265 WEBS 5-12=-135012406, 6-12=-867/806, 6-10=-239/565, 7-10=-386/506, 4-12=-867/807,4-14=241/565, 3-14=-386/508 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C E tedor(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20. plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 2, 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 399 to uplift at joint 2 and 399 lb uplift at joint 8. LOAD CASE(S) Standard ebWmssen.,lain+e.mulvnnaon�s¢iumlul[;emcm[maefMm'Ie�ra:urPo-2lrh5vPl•mw,reasen.bnwDv�®,mGIrt1°mm�.mril�enl,n ,n�usv.,,. mM,um.bveyrzareuaY a0tlaa'm1av��S4b,nibmn'ubYNtl,rLvra�p imp,'xnN.jrepNGpmxjfLssdnv114En♦mm�ompmv/mPd ll�grenyrt4mHa:�wh:@�IbP.Om,efcim�l�eNnmICUo11.4cAt Ainpm,pa�shCgm9m,tu�6p Anthony T. Tom6o 111, P.E. ' dowel lm,bmlvne bb.'p ',tlbow.bOrn(, vSxady9vbia�lAuga,vbmeE d&X&KII1616d Edoorad ML%gymddb low 'MmditI-1w Iw14 mnotbN].'molhvydflNhny OLgtl 260083 bm%yym hd foo,m. nletsmwvml[Oatlm Vvb,alPtlef>ntlbP�NgfminSf/gNncm(Nf wnwl, V1 wommnwx0fe unlprLm p.16Mi4rzyee{Imutlblad{.LrtsOevPe.lms hvp+Lp:rtdlmsYNuuiµaYu 44515C WCI26vd. AMulda%Iim(rlbg,tlrpbmftalbtllrM�LLNai Rlrmkaafq9n,410Ibb%9bPa.ainfSSrytvfgbm[mrhi%g. N,gklxlkrtbaoMmtlbllH. Fort Pierce, Ft 34946 (o Im®IDIDAllwi4vssev-Avllav i.ivmda Ill, P.E & mivmar vlliis domnem,®v Im rs mEBdedxitEvvl%e nioev efmissivofivm Ml9edinssesAvfEvv 7.1vmlv0, P.L VIl1 / r r Job TruSF russ ype ty ply A0209271 WRMSCM1560BIL A06 ROOF SPECIAL 1 1 Job Refoptional) tional A-1 Roof Trusses, Fort Pierce, FL 34945, deslgnigatw3s Wrn 6.00 12 Sx6 = Dead Load Deft. = 7/16 in 34 i 5x6 i 5x6 1 5 7 4 W4 3x4 i 6 1Sx4 i 13 6x8 = 8 w 12 71 5 d e'/ 1 2 91 3 '48x8 % 3.00 12 3x8 MT20HSx 2 910�4 3x4 16 15 3xfi = 6x6 = 2.4 11 48 7-8-4 11-10-12 19-0-0 28-1-9 1 380-0 7�i4 1 4-0-8 ~ 7-1_ 9-1-9 AN Plate Offsets (X Y)— 17:0-3-0 OJ-Ol 19:0-1-14 Edge], rl4:0-5-8 0-4-81 LOADING (psi) SPACING- 2-M CSI. DEFL. in (loc) I/defl Lid PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.71 Vert(LL) 0.49 11-13 >924 360 MT20 2441190 TCDL 10.0 Lumber DOL 1.25 BC 0.98 Vert(CT) -0.9611-13 >474 240 MT20HS 187/143 BCLL 0.0 Rep Stress Incr YES WB 0.89 Horz(CT) 0.57 9 We n/a BCDL 7.0 Code FBC2017fFPI2014 Matrix-MSH Weight: 1931b FT = 10% LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30'Except' B1,B3:2x4 SP No.2, 92: 2x4 SP No.3 WEBS 2x4 SP No.3 *Except' W3: 2x4 SP No.2 WEDGE Right: 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 2-4-4 oc pudins. BOTCHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 1 Row at midpt 4-13 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 1490/0-7-10 (min. 0-1-12) 9 = 1490/0-7-10 (min. 0-1-11) Max Horz 2 = 166(LC 11) - Max Uplift 2 = -400(LC 12) 9 = 400(LC 13) Max Gmv 2 = 1490(1-C 1) 9 = 1490(LC 1) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-2649/1686, 3-4=-4340/2667, 4-5=-3153/1816, 5-6=305211841, 6-7=-3136/1856, 7-8=4315/2672, 8-9=-4678/2898 BOT CHORD 2-16=1316/2291, 4-14=-233/447, 13-14=-2135/3999, 12-13=-189713634, 11-12=-1901/3609, 9-11=-2479/4215 WEBS 3-16=-1451/920,4-13=-1175/1004, 6-13=-1286/2346, 7-13=-8537776, WEBS 3-16=1451/920, 4-13=-1175/1004, 6-13=12862346, 7-13=-853/776, 7-11=315/579, 8-11=-337/439, 14-16=-156612749, 3-14=-720/1562 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 lost bottom chord live load nonconcurrent with any other live loads. 5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 9 Considers parallel to grain value using ANSlfrPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 400 lb uplift at joint 2 and 400 lb uplift at joint 9. LOAD CASE(S) Standard ev,Arc,=:.emddramrm7amr�(sotataraummrraummmlaurmrlPm7tn•ba irgmc,,ova:eoamAea:,oatrmb�m,.hftccmdmom�ltwaadrmv�mnnv mi„c .tlsedme<mr, y areto¢!vtw*A�NeWbbTNmMrtGtbeMup¢p Feyexpa.StiW69tlWnorNBnpom�mvrytasdhRAn�K»mr9�r9ner&hhrEsg:dhvgeL:ubAdoAeiWelfdrPtMHpcv,§+us6Sslmelew,cudb.'r Anthony T. TpII1ho III, P.E. ¢AnedNetrmmgNay AhmW bNdk O,ve:.hpmiramhd41rb1o�rABnhB.ahmmnAheCGCmIhbAM'fa9 el Ml.h@P}Md161Podwfax,:edl lms®LE9Ls@irNM1YffiPmetlhuiie6flbbnR:+rAfOd 3gL hraNey9nSadim'nd N¢RsalMtlhlf-0MmF+^mr®IpYdrsdt:tell^{frtp9SbylAxe_^Iv4P,pWblhlfldSWuercMtglYpm�g1'm.➢nOfintE:rtspa6iTeSWOMdlpllnf hYps.Imt Eup [[¢evmnmimffiM4m�[ 44515t. LucieBlvd. AMdvlQ dlreeffW qi:dM1nbeft4hdlleen Ntlrel hLvukagfymlelpimMYspl rym,etn::SlRa[ymwdmiM36�Ngee9bnanrdadalRl. Fog Pierce,R. U946 � (eppipAl®IDI6Ai rvofimzus-Amdavyi.iomhvlO,P.EPepmdvdivveftlisdvmmem,ueeyfnwispeviTdedxitlemMeximeepeimisuwhvm A�I HedLvsses-Amhvvyi.lomEolO,PF. Job Truss was ype ry y a WRMSCMIA0131L A07 ROOF SPECIAL 1 1 A0209272 Job Reference o tional _ ••-•_-_. ••==ro^tee •.,,.y...,^ nun: a,u s may la 2uaa root: n.zlu s maY 1a 2a1a Mu ex InoustneS, Inc. I nu reb 21 14:44:49 2019 Pagel ID:Id_OOXyyT61Bi_TXo1jwH HzefvK-6zVrM RYAf5Mfs5GJNuFoaOr7Jj49axspjFlOzuziurC 19.9-7 1d - T&4 11-10-12 18-2-9 1 25-(W 30-512 38-0-0 94 -0- ]Ed 63-13 90-.9. 52-70 SS11 7E-0 -4 6.00 12 5 8 7 Dead Load per. = 7/16 in 3.6 4 5x6 - 5 4 W4 3x4 3 W2 I 3 1 2 <p8x8 3.00 12 16 15 Us 6x6= 2x411 5x6 7 6 1.Sx4 4 8 13 4 5.8 = g 12 17 5 3x8 MT2011S_ 2 91 T v 3x4 = 4x8 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Well L/d PLATES GRIP . TCLL 20.0 Plate Grip DOL 1.25 TC 0.71 Vert 0.49 11-13 >924 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.98 Vert(CT) -0.96 11-13 >474 240 MT20HS 1871143 BCLL 0.0 ' Rep Stress Incr YES WS 0.89 Horz(CT) 0.57 9 We n/a BCDL 7.0 Code FBC2017/TPI2014 Matrix-MSH Weight: 1931b FT = 10% LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30'Except' B1,B3: 2x4 SP No.2, B2: 2x4 SP No.3 WEBS 2x4 SP No.3'Except' W3: 2x4 SP No.2 WEDGE Right: 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 2-4-4 oc pudins. BOTCHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 1 Row at midpt 4-13 MiTek recommends that Stabilizers, and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 149010-7-10 (min. 0-1-12) 9 = 1490/0-7-10 (min. 0-1-11) Max Horz 2 = 166(LC 11) Max Uplift 2 = -400(LC 12) 9 = -400(LC 13) Max Gmv 2 = 1490(LC 1) 9 = 1490(LC 1) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOP CHORD 2-3=-2649/1686, 3-4=4340/2667, 4-5=-3153/1816, 5-6=3052/1841, 6-7=-3136/1856, 7-8=-4315/2672, 8-9=4678/2898 BOTCHORD 2-16=-131612291, 4-14=-233/447, 13-14=-2135/3999, 12-13=-1897/3634, 11-12=-1901/3609, 9-11=2479/4215 WEBS 3-16=14511920, 4-13=-1175/1004, 7-13=8537776, 7-11=315/579, WEBS 3-16=1451/920, 4-13=-1175/1004, 7-13=-853f776, 7-11=315/579, 8-11=337/439, 14-16=-156612749, 3-14=-720/1562, 6-13=-128612346 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psF, h=15ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 9 considers parallel to grain value using ANSVTPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 400 lb uplift at joint 2 and 400 lb uplift at joint 9. LOAD CASE(S) Standard avo<•r�MVLmgYlmbrm'414pffi1fRrLlFrtrMi41N4eCG0[YSI4IARCI4'j WRAlfll'im fatllhgpWmml�quwmslmsMvp4wyllW`,dmlMgticb4rElEvva2ENxam 80s;�alu GV nYIDl.m'I LidmvMlaY;il3bmtmmnOnbuLLA�atm;Repfi�.ea.ym¢Lpu9am WuglnrtRum;n;mzeOmRtlrs;mdymM1ln4m4yVbmk�gatlmsb$etnutA+YtnLeOUII, tlnAL lYlapma'v^ua Ydgmlentu.N'�1 Anthony T. Tomb017I, P.E. ' mwnm lm;YquYgnmmp�dltaem0.an,60.w,=fn¢tlglemlvZryonya,Ym�mevtlmm,eeKNa,klpdzy�we4u4t tbq;pnnaammedwrauosaarmckk5gteq�tgs YnmmmSagilmbmn�rabagd .^80083 j mlaYgtnpetlrm�M. NebslRabRM olmlmm;apitlmtlNkley (myasW�gfl:om rNMfpNclSWuudvsOhlmelprdsu 1FF16Au;Euq,m90:e�eEla�[kLu;O�YRe,imvhsR6pecmlfnuVSNwu,eku 4451 St. Lude Blvd. MmvNwl plafa4NalntlrvYnCyb®Iad;YNrei 4eivssquP[gYmLi0lmltlYglalv,ulnu Snxa tapeu4ol4Liy NgC1¢Jtrmazn14da141. �(YppailW®IDIdAlloaf8ams-AelYneyLiamEYin,pt tepmdoaioa onlhdommem,aaoptoim,isprah3ihdxiid:mlhe annex peimissiwhom A -I rodGnuo-Au6vvllJa®to IO,PL FOR Pierce,R 34946 O russ mss Type City A02092]3 WRMSCM1560BIL A08 ROOF SPECIAL 1 1 Job Reference-o 'oral A-1 Roof Tmsses, Fort Pierce, FL 34946, design@al9ose.cmm 3x4 i 2 5xi0 MT20HS= 6.00 12 US 4z6 ! Y 5x6 5 7 4 W4 _- 6 13 6.8 = 12 it D18x8 % 3x8 MT20HS= 3.00 F12 3x4 16 15 US = 6x6 = 2x4 It 1.5x4 i 8 ' 7761410812 I 7-0 8-1 30 1_4 9-99 -7 4x8 Dead Load Deft. = 7116 in Plate Offsets KY)- 17:0-3-0 0-3-01 19:0-1-14 Edgel r14'0-5-8 0-4-81 LOADING(psf) SPACING- 2-M CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.69 Vert(L-) 0.49 11-13 >927 360 MT20 2441190 TCDL 10.0 Lumber DOL 1.25. BC d.98 Vert(CT) -0.9611-13 >475 240 MT20HS 1871143 BCLL 0.0 Rep Stress Ina YES WB 0.88 Horz(CT) 0.57 9 We n/a BCDL 7.0 Code FBC2017frP12014 Matrix-MSH Weight:192lb FT=10% LUMBER - TOP CHORD 2x4 SP M 30 SOT CHORD 2x4 SP M 30 `Except` 81,B3: 2x4 SP No.2, B2: 2x4 SP No.3 WEBS 2x4 SP No.3 `Except` W3: 2x4 SP No.2 WEDGE Right:. 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 2-7-6 oc pudins. BOTCHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 1 Row at midpt 4-13 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation quide. REACTIONS. (lb/size) 2 = 149010-7-10 (min. 0-1-12) 9 = 149010-7-10 (min.0-1-11) Max Horz 2 = 165(LC 11) Max Uplift 2 = -400(LC 12) 9 = -400(LC 13) Max Grav 2 = 1490(LC 1) 9 = 1490(LC 1) FORCES. (D) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOP CHORD 2-3=-2650/1686, 3-4=-4338/2665, 4-5=-3189/1838, M- 3086/1861, 6-7=-3169/1875, 7-8=-4315/2672, 8-9=-4678/2898 BOT CHORD 2-16=-131712292, 4-14=235/450, 13-14=2129/3991, 12-13=-1897/3635, 11 -1 2=-1 900/3610, 9-11=-2479/4215 WEBS 3-16=1452/921, 4-13=-1132/969, 7-13=818/745, 7-11=-316/579, WEBS 3-16=1452/921, 4-13=1132/969, 7-13=818/745, 7-11=-316/579, 8-11=337/439, 14-16=-1567/2751, 3-14=717/1558, 6-13=-1269/2320 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult--160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psF h=15ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 400lb uplift at joint 2 and 400 lb uplift at joint 9. LOAD CASE(S) Standard YaeIRmCmryHrminm'UpC'rr1m16(fltla}&Ai1LIa0Se[[611Pq�lOtl-tllr�laYCMilnI'mm.letllk9ppaYmdaE dneCelrm+Oeg�kuq(f[{nd4LSsri. tvA4lEhkw&rtihsema. &ImsoEn6YatlwhNA,a`, (/_�\ Wetmam,fAm3Aeewelmdnp®YNIL Iulmi kt9afr¢ttp..l{x'ItQf butlaarlABnitm2ce.vpanCMptlec9u]ee(sml,IrtyedOgdmk�pYmSYjerwtytltlahl[-0Wr.tla10.1. biMpmwpYm.Y'varWEa6m4Y69 pnlhonY T. Tmbo 711, P.E. J \ dmYka GrsbmlYlr:nmrtgwYtMtldOne.dOmtf,�vd,NeNbYu34eks.ORmsEtlmYf.MCoiOehmdYrrMemPA 160P�NdmIBBmlardlwrd6,riots&�LaQ#sap.YN'drnChaq dflhdnK+ E 38008390083 \\ dwYgeegmmremm. wmesvnw.amoadla�swlpnYmsammugk.Pmnstrrytlnca;mpPeaegtnaaumrtu®f6ym..i 44518E Lucie Blvd. (/U■ dsska=se.a,wwueametmxsYmumdapa.tm.mgtigxamtmremnwa,a�ru wopa etnn.tlivaheummemmwns.�myhYlwm+aamE>biro:dytgm,klotduaapomgm,mNmsluaelswarpkslq Adwnmtrdetrn. Fort Pierre,R 34946 � doppipht®1d76Ai loeRiesses-Av11ve1LiomAalli, PE Aepmdeaioadtlisdommem,iomgtYim.isproA0ihl wAdemtdevrimepermisdmhmA-I IY97nsses-AmEwrr.iamlol4PE a toss russ ype ty y WRMSCM1580a1L A09 ROOF SPECIAL A0209274 1 1 Job Reference o Bon al ^ ••.w•_____. ��.�•_�_. �� ...... nun: a.zlua may I 2g1a enm:a.zlu s may lb tun a mn exinausrnes, Inc. I nu heb2114:44:512019 Pagel ID:ld OOXyyT61Bi TXoljwHHzefvK-2Mdbm7ZQAicN60QNJIGfRxShWoi2gy6AzEW2mziurA • ♦ 1-0 ]6-0 11-10.12 14-0-1 16-8-1 19-0-0 21-3-15 23-7-15 54) 30.5-12 36-0-0 94 1L 7-6-4 4-0-9 2-SS 2-4-0 2-3-15 2-3-15 24-0 1-4- 5' 7fi-0 1 6.00 12 5x6= 1.5z4 II 85x6 // Dead Load DeFl.=7/161n 2z4 II 5 7 3x6 1.5x4 II 49 3x8 MT20HSC 4 5 5 3z44 4 10 3z41 3 11 17Z 4 W2 5x8= W9 0 1615 5 r 0 2 3 rv5x8 = 3x8 MT20HS� 14 c 1 3.00 12 3x8 1.5x4 II 12fm 20 19 3x6= 6x6= 2.411 48= 19-1-12 7EA 11-10.12 18-104 19A 25 1 2&1-9 305-12 3 7d4 6.11.3 61! 2 S-- 3-1-8 I 2-0-3 I 78b0 - a1-12 Plate Offsets (X )I z (6:0-3-0 0-2-01 t12:0-1-14 Edgel 118:0-2-4 0-3-0T LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (too) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TIC 0.78 Vert(L-) 0.48 15-17 >954 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.85 Vert(CT) -0.89 17-18 >510 240 MT20HS 187/143 BCLL 0.0 Rep Stress Incr YES WB 0.92 Horz(CT) 0.58 12 n/a n/a BCDL 7.0 Code FBC2017/TPI2014 Matrix-MSH Weight: 2061b FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 `Except` T5: 2x4 SP M 30 BOTCHORD 2x4 SP N0.2 `Except` B2: 2x4 SP No.3, B5: 2x4 SP M 30 WEBS 2x4 SP Na.3 `Except* W3: 2x4 SP No.2 WEDGE Right: 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 2-2-0 oc pudins. BOTCHORD Rigid ceiling directly applied or 4-8-3 oc bracing. MiTek recommends. that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 1490/0-7-10 (min. 0-1-12) 12 = 1490/0-7-10 (min.0-1-11) Max Horz 2 =-147(LC 10) Max Uplift 2 =-385(LC 12) 12 =-385(LC 13) Max Grav 2 = 1490(LC 1) 12 = 1490(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-2654/1667, 3-4=-4166/2503, 4-5=-4070/2517, 5-6=4201/2689, B-9=-4021/2572, 9-10=-3955/2402, 10-11=402512384, 11-12=-0653/2817, 6-7=-3504/2089, 7-8=-3504/2089 BOTCHORD 2-20=-130012296, 5-18=-255/308, 17-18=136413105, 16-17=-1344/3096, 15-16=1 351/3077,14-15=2410/4199, 12-14=2404/4184 WEBS 3-20=-1392/875, 6-17=-369/956, WEBS 3-20=1392/875, 6-17=-369/956, 8-17=-394/975, 8-15=791/940, 18-20=1532/2726, 3-18=592/1398, 6-18=879/1048, 9-15=-310/348, 11-15=-572/571 NOTES- 1) Unbalanced roof live loads have been considered for this design. - 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; CaL 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Extedor(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL= .60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) `This truss has beendesigned for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 12 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 385 Ito uplift at joint 2 and 385 Ib uplift at joint 12. LOAD CASE(S) Standard rnmlr nnnehmmm•ulmrmm�(tuiatsmiunlyirruemdamtmCxralw€sa;un•m.lnrmsrlmmun,dm.ss.eat.,,rm$+mv.ellararm+mnl»ult!mwaxxt.n. ¢amvm+moa.mmru; i Cyawxn,pbrammrnmmmouaro.Asvmuhnphpe0a.gnal _t i•,muaugm>npevmmmpmaampmwoigsegrey.,aahmmsumdmsulvinuymumlwuy. mumt ueWnuapu.aagmm.snaiy Anthony T. Tembo ffl, P.E. I dma6r lmsbgkngnmrtsW�9�1r4pnn.mOm/rrlmetlgetuml:Irg4nlP.rmnnvamm.mummYdkrAu4aipu.mymtlamm9dwabneemimxtm0pteagmq:,:MsntlkugfL�€hb,Wmashd +80083 mma.pp.y.mrmv�.u.m>RmnmtpodmrmresmpmmnummngayansmynumAsnv!lem+kmmuun.iert�mlar�npe�mia�mtengmaamcaa.aaeume<upu.lm.on¢ugunmar.ar=rmur!ns 44515LLucle Blvd. • rmmuldvtlh.Gkmeyetlgenx,mph2lpmxmdret lklnuk:�9[q'aseramtllyri�x,r,inulrme6l:mImlW4q Ney3:mlAmvamNbtlenVL Fort Ne¢e,R. 34946 (vppipM®IDdd AA IvelLvsses-Amlavpf.lvmEolO, P.E lepmdvauvvftlndvmmem,ivvrylvrm.ispmELAedrAhvmMv.nlleepumissiwhvmA-I9volirvvsesAVlhvvrLtomlvlll,Pi Job Truss cuss ype y A0208275 WRMSCM1560BIL A10 Hip t t Job Reference o tional A-1 Roof Trusses, Fort Pierce, FL 34946, design@albuss.com Run: 8210 s May 18 2018 Print 8210 s Mayy 18 2018 MTek Industries. Inc. Thu Feb 21 14:44:53 2019 Pagel ID:ld_OOXyyT61Bi TXe1jwHHzefvK-?IILBpbhiKs5Lia4ckKkksOoMKUeWnmPeHjd6fziur8 14-8-1 - 139 11410.143-15 24133115 2-0-0 28-7-8 I 31-7-1 38-0-0 3-03-01-9739 2 052-00 5 2-11-9 2 -0 fi-0-15 t-0-0 5x6 1k 6.00 12 1.5x4 11 6 7 4x6 i 4x6 i w 3x4G4 3 16 - - '�_ 6x8= 3x4 2 y 1 3 Us 3.00 12 20 19 3x6 = 4x6 = 2x4 II 7-3-9 11-10-12 14-8-1 19-0-0 5x6 ll 8 4 5x6 9 1.5x4 II 8 10 15 14 4x6 3x4 13 3x4 c 23315 25-M i 31-7-1 i 38-0-0 4x8 Dead Load Defl. =12 in 7-3-9 1 1 4-7-2 2-9-5 1 4-3-15 2-40 5-11-2 6-4-15 Plate Offsets (X Y)- (4:0-3-0 Edoel r9:0-3-00-3-01 r11:0-1-14 Edoel r18:0-5-4 Edcel LOADING(psf) SPACING- 2-M CSI. DEFL. in (loc) Well Lid PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.77 Vert(L-) 0.55 16 >833 360 MT20 2441190 TCDL 10.0 Lumber DOL 1.25 BC 0.88 Vert(CT) -1.00 16 >456 240 BCLL 0.0 ' Rep Stress Incr YES WS 0.71 Horz(CT) 0.65 11 n/a n/a BCDL 7.0 Code FBC2017/rP12014 Matrix -MS Weight:2041b FT=10% LUMBER - TOP CHORD 2x4 SP N0.2'ExcepY T5: 2x4 SP M 30 BOT CHORD 2x4 SP No.2 *Except* B2: 2x4 SP No.3, B5: 2x4 SP M 30 WEBS 2x4 SP No.3 *Except* W3: 2x4 SP No.2 WEDGE Right: 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 2-2-0 be purling. BOTCHORD Rigid ceiling directly applied or 4-3-9 oc bracing. MTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 149010-7-10 (min. 0-1-12) 11 = 149010-7-10 (min. 0-1-11) Max Horz 2 = 131(LC 11) Max Uplift 2 = -371 (LC 12) 11 = --371(LC 13) Max Grav 2 = 1490(LC 1) 11 = 1490(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-2665/1655, 3-4=4181/2469, 4-5=-4100/2484, 5-0=-3710/2216, 6-7=-4766/2733, 7-8=-4766/2733, 8-9=-3779/2189, 9-10=-4540/2885, 10-11=-4655/2767 BOT CHORD 2-20=1294/2309, 5-18=-255/358, 17-18=1908/3789, 16-17=-154413374, 15-16=1646/3393, 14-15=-155413380, 13-14= 2207/4036, 11-13=-2366/4181 WEBS 3-20=13371843, 18-20=-15132695, WEBS 3-20=-1337/843, 18-20=-1513/2695„ 7-16=-272/221, 3-18=565/1383, 6-17=-341/470, 8-14=-261/451, 6-16=862/1780, 8-16=-852/1755, 9-14=621/635, 9-13=-247/303, 5-17=525/468 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCOL=4.2psf; BCDL=4.2psf; h=15ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water policing. 4) This truss has been designed for a .10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 11 considers parallel to grain value using ANSI/TPl 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 371 lb uplift at joint 2 and 371 lb uplift at joint 11. LOAD CASE(S) Standard Pmgkupmvt"-0,m�b411lq`9A46r4LLmI4AaLL Nxf r@411ICnU61W11'1L14'j4ll64.EieFfIT6rm 1etlr4Yp Noxmddr9nv0,lmr&uPOmmgIIOGIdIb1EW(I.k2e41E1eM1meAx�M+xee OdssCnlus6JmMNl,m} //�\ Wtlmx:6,lil,YSYaNYhn4bM,dlL isaimt4v$b,muOa.lg'+1!54= OrWnvltlUnPmfio[somas/EePknLlaY'�4e9�nuVbtleMWtltl�YAimtlSm�ApM1C0�. dfAL Min4vminm.6as'ieU"m�.Ctl14'i AnitlOnY T. P.E. / \ aB,. m9aw4wmdMv3�mbeanY+�aOe 800Ib0II1, .'80083 A..lahow,.bout,e�drgm"ftg szelanemia¢l:rCvlmw�A.k velft o'v'emmrdm@IdnetMlmv.il�bGq NW,Drmrbvr ' N4kpunmdrmw NvnNmvblpBtlblmlaselpmc�tlbaJdg4mrrcmfNgaaemnlieglWdry4lNPUm,Fvm2h�YP2m^ 4451 St: Lucie Blvd. sm.ww.4gerysmyMmma.avprympuvmdat l4imsR'uPrq'avmr0lbbaglcpv,aL,uiPxatgbmdvrWhA wopa.,dtrnmmlemnmi. Fart Pierce, FL 34946 (epprilhl®401AAIlvvlimsses-AmlevpLivmAel0, LL lepmdvaivv oflAistomvum,iv vry6rm,ispivhih'velriih:ml6e rnircepermissivsh,.Alhi,Tnsus Av1viiy .Tocl,11,P.L i Truss I rlss I ype ly WRMSCM7S50BiL A11 Hip A0209276 7 1 Job Reference (optional) rtum m.� ID ld_OOX yT61BI TXc IO:Id_OOXyyT618i_TXr 1 17-0-9 t 21-5J 25.4-0 4-0-9 44-9 3.10-13 6x6 4 4x8 = 2x4 II 5.8 = Dead Load Defl. = 7116 in 3x6 = 1.5x4 11 3.6 = 3.4 = 6.8 = 2x4 11 48 72-8-0 77' 21-5-3 2T 31-5-7 38-0-0 6-7-4 6-0-72 4-4-9 l 4�-9 1 3-10-13 I 6-1-2 6-6.t1 Plate Offsets (X Y)— r4:0-1-12 0-1-121 r5:0-3-8 0-2-01 17'0-6-0 0-2-81 (9'0-1-14 Edcel r14:0-3-4 0-3-81 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.66 Vert(LL) 0.55 14 >823 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.95 Vert(CT) -1.01 14 >452 240 MT20HS 187/143 BCLL 0.0 Rep Stress lncr YES WB 0.86 Horz(CT) 0.58 9 n/a n/a BCDL 7.0 Code FBC2017fTP12014 Matrix -MS Weight: 215 Ib FT = 10% LUMBER - TOP CHORD 2x4 SP M 30 *Except' T2:2x4 SP No.2 BOTCHORD 2x4 SP M 30'Except- 131,B2: 2x4 SP No.2, B3: 2x4 SP No.3 WEBS 2x4 SP No.3 *Except* W6,W5:2x4 SP No.2 WEDGE Right: 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOTCHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 1 Row at midpt 5-16 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 1486/0-7-10 (min.0-1-12) 9 = 148610-7-10 (min.0-1-11) Max Horz 2 = 114(LC 11) Max Uplift 2 = -353(LC 12) 9 =1 -353(LC 13) Max Grav 2 = 1486(LC 1) 9 = 1486(LC 1) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOP CHORD 2-3=-2707/1667, 34=-2174/1417, 4-5=-2078/1470, 5-6=5401/3107, 6-7=-5423/3114, 7-8=4051/2320, 8-9=-4688/2791 BOTCHORD 2-19=-132412358, 18-19=-1324/2358, 17-18=-1324/2358. 16-17=897/1868, 13-14=-1766/3661, 12-13=2406/4245, 11-12=-2410/4226, 9-11 =2397/421 9 WEBS 3-17=568/504, 4-17=193/375, WEBS 3-17=-568/504, 4-17=1931375, 7-14=-110412163, 7-13=-189/380, 8-13=-583/620, 5-16=-2175/1164, 14-16=1375/2799, 5-14=-188313819, 4-16=219/483 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=.160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Extedor(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads. 6)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 353 Ib uplift at joint 2 and 353 lb uplift at joint 9. LOAD CASE(S) Standard rei¢i.l4nsepu,g6iiuurp•mr�faIIf6(SFltfYy 6tLilt1964Cu§:IIIn1(RI]Y•tnT WCi:EpJ&Irbn IetlykCPlmmtlmdrtyeannBnimsOugbv.v!(IW;dhLtleii.IebRlE4knv4MkhTnv llmvOnb4Mo0,iCB.aj Mllela¢mil'+'+sOAbrz(Mb1i4bNn4tls.tms®r Pfy-xalle.Sryetih bWagN9rtmepcvup»dNp@ataigexwrtyvHfie�4Qslnd6Eesyk imstga!IxLifAwp.dulM1t tbes¢+msulnxa6rtsimONvvn90[ Anthony T. Tombo 111, P.E. I H,oel im;sh Qkv' PomP.'!gd49m.6,Qrm'se�trNdgc9epkH'vgWga..pMv090Ctl Kwal W l voah W RL n!"oJibiawoow r6Gimvt1,551rd'xgSp�b'i9'. Worm"9 trnspalgd T89083 bkixxi0mya. dernu. NnpielmlbpmPmip CmmsmlFtlxs8ikr2dy4gsudll AbYaeiu(q[�PJNd�IWtl9ameMxmfO �dytlan iY.itlmskrtpaisesNHb¢LLmhuPr.imrM4¢Prv¢llnsstlmluman.ws 44615r. Lucie �mNsei6tlpar,aelryW gvYvrmq¢dIryMKArtL ilrinmb;graan,hr6tbrdailb4m,eLnslry+ahlYmdmiMdly. Wgeimltrasusm45rlmlM1l. � Fort Pierce, FL 34946 3494 L Df®40IAA4 [oetlnsses-Anlloe LdomAo111, P.E [e mdoai000hhis lomme m fo is mhiAihdri%em�e come emwssiorhom4l leolinssn�Amhoe Liemrol PFiA / P m., mr rm. P P r 4 Pi oTruss N6aType N v A0209277 WRMSCM15fi0B1L Al2 Hip 1 1 e Job Reference o tional A-1 Roof Trusses. FartPierce, FL 34946, design@at W ss.WM nun: d.nu 5x10 5x10= 3x411 704 M1-20HS= Dead Load DeB. = 5/8 in 3,6 = 314 = 3x6 — 6x8 = 2x4 11 4x8 18-2-9 2153 27-0-0 38-0-0 11-n-n 7-2-9 3-2-10 5.6-i3 11-0-0 Plate Offsets(XY)— T2:0-2-120-1-8115:0-3-80-2-81 f7:0-6-00-1-81 f9:0-1-14Edoel it 1:030Edoel 112:0-0-00-3-81114:0-1-120-2-81 LOADING (Pat) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defi LJd PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.97 Vert(L-) 0.78 12 >584 360 MT20 2441190 TCDL 10.0 Lumber DOL 1.25 BC 0.82 Vert(CT) -1.42 13 >321 240 MT20HS 1871143 BCLL 0.0 Rep Stress Incr YES WB 0.92 Horz(CT) 0.75 9 n/a n/a BCDL 7.0 Code FBC2017/TP12014 Matrix -MS Weight: 2021b FT = 10% LUMBER - TOP CHORD 2x4 SP M 30 `Except- T2: 2x4 SP 2400F 2.0E BOT CHORD 2x4 SP M 30 `Except` B3: 2x4 SP 2400F 2.OE, B2: 2x4 SP No.2 WEBS 2x4 SP No.3 `Except- WS,W6: 2x4 SP M 30 W4: 2x4 SP 2400F 2.0E WEDGE Right: 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 4-6-8 cc bracing. WEBS 1 Row at midpt 5-14 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 1486/0-7-10 (min. 0-1-12) 9 = 1486/0-7-10 (min. 0-1-11) Max Horz 2 = -101(LC 10) Max Uplift 2 = -337(LC 12) 9 = -337(LC 13) Max Grav 2 = 1486(LC 1) 9 = 1486(LC 1) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOPCHORD 2-3=2680/1699, 3-4=-2320/1458, 4-5=-2438/1649, 5-6=8063/4506, 6-7=-8265/4633, 7-8=4248/2403, 8-9=-4721/2886 BOTCHORD 2-16=-1364/2363, 15-16=-981/2013, 14-15=-981/2013, 11-12=-1904/3870, 9-11=2492/4264 WEBS 3-16=404/444, 4-16=126/438, WEBS 3-16=404/444, 4-16=-126/438, 5-12=3209/6316, 7-12=-2486/4674, 7-11=-77/369, 8-11=398/571, 5-14=3350/1837, 12-14=198813869, 4-14=345/648 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult--160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) `This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 7.Opsf. 7) Bearing at joint(s) 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 337 lb uplift at joint 2 and 337 lb uplift at joint 9. LOAD CASE(S) Standard rewmmm�mMmo.m•urocrnmrs[�rtaiutmurmcm[urmlm�-wrsluucsa;eafma vxna�cr=ammmm.a=m1m,u,�s¢+4;�nimmr.m.rtt�,e:riw,m,axu R mn..wmoAmtoa.w7 //_�� kRAmrs9nmb.sL9h.vtlmm151uhNiurtm,rvYpt¢yer(u-ye lrmW imutlngl4onPmm®a amr,mnmtlspuwrc�nm�trae,wem�sMtnslyxuemmoM.Wumtmhpnnopr meyaami r4lmp k6onY T. Tombo III, P.E. tlewft tm.a nl mmlmm,upsAJPdlhx..moPm':e¢smd.WVNkItu MiP..@hmamllCmCelmialNYgMe W M m W Idb TOW'Wrs.mmims m4"+9mdin¢ '6fi53 dwmuhft"Ie9 s80083 mP+kGAngvd4mM. AluesW¢atlmiWNml��adtlP¢e�6mmtldgfe¢pm3EvgKn9mlldjpklWdhmm�^¢�demlkP=Pdm>an�ldrLrtgmAlmueibaa[NLnzgmpe.i.wYevp5¢uemlri,sslahm�eebn 44515L Lucie Blvd . .LmvlffadlrfetmrrdepmarJgptlllam,mrcntll.irtuhnp[gnsm NtmmY�ih;W+m,dNsslnRefgamdvtW4y alg39mtlbemmtld+tlb1141. U Fort Pierce, FL 34946 �(oppirhl®101r41!¢¢Rnssrs-Amhaoyl.l¢m5¢IIIP.L@pmd¢di¢vd@isdommem, icaryb�m,ispr¢E3u¢lxilhomm¢mLmpeimissimhom4l p¢dLnuv-Aeihvoyl.IomEoill,ri Job Muss I fuss ryw—po y WRMSCM15�081L A13 Hip A0209278 1 1 Job Reference o Nonal A-1 Roof Trusses, Fort Pierce, FL 34946. deagn@altn ss.com Run: 8.210 a May 18 2018 Print: 8.210 a May 18 2018 Mmek Industries, Ina Thu Feb 21 14:44:55 2019 Page 1 940 ID:ld_OOXyyT61Bi—TXo ijwH HzefvK-x7t6cVdxEx6pa0kTk9MCpH58h8HK—hYiSbCkBYziur6 -1+0 aa15 t+0 4415 8 + 12J 15-5-0 19J 3]3+] if szd I2-1 2a214 29A" I 33-0-0 38-00 92 1/2 �10 0.7-9 6z6 1.5z4 II 3x6 = 3z4 = US C 3z4= sxIu= 20 3x6 = 414 = 2x4 II 3x6 II 3z6 = 1 5x4 II 3x6 = Bx8 = 2x4 11 Us — 2x4 II 5.8 = 9 H 21- 3 19-0af Od-a 29A0 33a0 3841-0 4-0-1s i b3.8 ICI 6-s0 3-1a MY 4A0 500 0.7-9 1- 12 Plate Offsets (X Y)— 15:0-1-12,0-1-121 19:0-1-12 0-1-121 118:0-5-12 0-2-81 123:0-5-12 Edgel LOADING(psf) SPACING- 2-0-0 CS]. DEFL. in (loc) I/deft Lld PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.71 Vert(LL) 0.13 15-16 >999 360 MT20 2441190 TCDL 10.0 Lumber DOL 1.25 BC 0.36 Vert(CT) -0.11 21-22 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.75 Hoa(CT) 0.03 11 n/a n/a BCDL 7.0 Code FBC2017ITP12014 Matrix -MS Weight: 2241b FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP N0.2 *Except' B5,32: 2x4 SP No.3 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 5-2-3 oc pudins. BOTCHORD Rigid ceiling directly applied or 6-0-0 oc bracing. Except: 9-11-0 oc bracing: 22-23 10-0-0 oc bracing: 23-25 WEBS 1 Row at midpt 9-18 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 765/0-7-10 (min. 0-1-8) 16 = 1728/0-7-10 (min. 0-2-1) 11 = 512/0-7-10 (min. 0-1-8) Max Horz 2 = -84(LC 10) Max Uplift 2 = -203(LC 12) 16 = -664(LC 9) 11 = -328(LC 8) Max Grav 2 = 776(LC 23) 16 = 1728(LC 1) 11 = 538(LC 24) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 23=-12417710, 3-4=1179/671, 4-5=-948/590, 5-6=509/344, 6-7=-509/344, 7-8=509/344, 8-9=-296/626, 9-10=349/696, 10-11=-686/1049 BOTCHORD 2-26=489/1070, 22-23=-355/1013, 21-22=2331858, 19-21=-625/645, 18-19=-5301808, 14-15=-8151565, BOTCHORD 2-26=489/1070, 22-23=-355/1013, 21-22=-233/858, 19-21=-625/645, 18-19=-530/808, 14-15=-815/565, 13-14=-815/565, 11-13=-815/565, 4-23=136I258 WEBS 16-18=1572/1194, 8-18=-1123/774, 9-15=549/309,15-18=-197/339, 9-18=950/1096, 5-22=-1761405, 23-26=-441/946, 4-22=-313/239, 6-21=384/330,5-21=429/271, 8-21=742/1283, 10-15=-357/560 NOTES- 1) Unbalanced roof Jive loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed; porch right exposed;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water pending. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) `This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to hearing plate capable of withstanding 203 lb uplift at joint 2, 664 lb uplift at joint 16 and 328 lb uplift at joint 11. LOAD CASE(S) Standard FVWMl m. rilurQa.ivvCJumm®.cj Sr..S1,M[01Mtl1�SY�i'SeWI'Yrm IeC16,MM•,mll d' n..EMf lbldyfmY.m•ua04kn97{WDr IVP h Naiod�!d0,afvr .0.ra irna.9MElat YII,ImxmMbrilAhra1Wm19P9mm4li.uminip6pxpa.11mr%e}xy mutlwq�Vinpwmouv,77,camp,4nmtlw�in4m,ule�bmlrpemsy,rm,M{mdoe,loDep.delht lY4,gm,apnw.YGgmDrmywilC% Anthony T. Tombt1111, P.E. ru,d0n Mrm.ik'O1lvmrtsPsm�%tlm Om,.m OVdrrbmtlg9.mlilmlms4'v.Vmmmndmm.4eComFdmYUMnkrwtfi3xnJimID9dwte'JmdmlmtRhi9tr'r4MµmxA6edtre4 ilANhmP�kd11d1 980383 mmzgMuecrtmx.. muzsum.m¢edmlrmsrpaumnmaeyoyuvse,tm:uev.P�Maure%tndroammu�4mpmr�m mlaa.euy®>arssdmamumhap.muouWapuumtmsse u,us,s 44515t. Lucie Blvd. ,4vVm WVdll.frmmr,x,.V,mghmmm.md tmlmcduAt9'n,ulmmlflgMcGe.elnufrmaanmdormOEy ugitlmlbomnl9dGmt � Pod Pierce, P. 34946 GpprilAl®10I{AI IvdLvsses-Av8vryLlvviv Dl, P.E lepmlvoivvvPoislvmvem,®mrhrgispmb'ENelydEvNlErvnnevperminim6em A -I &dinsm-Aehwrl.Iavlv0l,ri was russ ype ty y A0209279 ro WRMSCMi560a1L A14G Hip Girder Job Reference o Oonal A4 Roof Trusses, Fort Pierce, FL 34946, Lesign(datbuss.mm nun: 5x10 MT20HS= 6.00 12 5 3x4 1.5x4 II 5x6 = 1.5x4 i 11 Dead Load Deb. =1/81n 43 44 23 45 4fi 24 2 �tl A8 U, 27 26 25 1.Sx411 21 18 19 H9 50 51 16 1552 53 14 616 = 3x6 11 4x10 3x6 11 3x8 = 3xfi = Sacs - 3x6 = - 8x8 = 2x4 11 2x4 11 5x12 = 21A3 4-0-0 ]b0 3d6 11-11-1516-10.1 194-7 0-0- 263-12 � 26A-2 3:1g 384]-0 4-0-0 3-0-0 Itdb~ 3-)E 1-10.8 2-11-10 24ifi 4- ]-8�0 6 4]-14 ]-00 1313 Plate Offsets (X Y)- r10:0 3-00 2-01 (16'0 0 0 0 1 121 r16:0-2-0 0-3-0] r19:0-3-12 0-231 f24'0.5-12 Edgel LOADING(psf) SPACING- 2-M CSI. DEFL. in (Ioc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 1.00 Vert(L-) 0.13 23-24 >999 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.81 Vert(CT) -0.24 23-24 >999 240 MT20HS 1871143 BCLL 0.0 Rep Stress Incr NO WB 0.74 Horz(CT) 0.07 12 n/a We BCDL 7.0 Code FBC2017/rP12014 Matrix -MS - Weight: 218lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP N0.2 `Except` B2,B5: 2x4 SP No.3 WEBS 2x4 SP No.3 `Except` W7: 2x6 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied or 3-2-15 oc puriins. BOTCHORD Rigid ceiling directly applied or 5-3-13 oc bracing. Except: 10-0-0 cc bracing: 24-26 WEBS 1 Row at midpl 6-19, 9-19 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation quide. REACTIONS. (lb/size) 2 = 129310-7-10 (min.0-1-9) 17 = 3946/0-7-10 (min. 0-4-11) 12 = 720/0-7-10 (min. 0-1-8) Max Horz 2 = 68(LC 7) Max Uplift 2 = -444(LC 8) 17 = -2040(LC 5) 12 = -581(LC 4) Max Grav 2 = 1299(LC 19) 17 = 3946(LC 1) 12 = 731(LC 20) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOP CHORD 2-3=-2366/801, 3-4=-2612/916, 434=-2208/808, 34-35=-2207/808, 5-35=-2207/808, 5-36=-2207/808, 36-37=22071808, 6-37=-2207/808, 6-38=948/2144, 38-39=-948/2144, 7-39=-948/2144, 7-8=-950/2159, 840=950/2159, 9-40=-950/2159, 9-01=792/917, 4142=-792/917, Continued on page 2 TOPCHORD 2-3=-2366/801, 3-4=-2612/916, 4-34=2208/808, 34-35=-2207/808, 5-35=2207/808, 5-36=-2207/808, 36-37=-2207/808, 6-37=-2207/808, 638=948/2144, 38-39=-948/2144, 739=-948/2144, 7-8=-950/2159, 840=-950/2159, 9-40=-95012159, 9-41=-792/917, 41-42=-792/917, 10-42=792/917, 10-11=-928/995, 11-12=1131/1050 BOT CHORD 2-27=-706/2072, 2443=-796/2393, 43-04=-796/2393, 23-44=796/2392, 23-45=-96/604, 4546=-96/604, 22-46=-96/604, 22-47=-96/604, 20-47=96/604, 20-48=01700, 1948=0f700, 17-50=-1077/394, 50-51=1077/394, 16-51=-1077/394, 15-16=1077/394, 15-52=376/0, 52-53=-37610, 14-53=376/0, 12-14=-895/985, 24-26=451409, 4-24=156/780 WEBS 17-19=3668/1868, 7-19=-097/314, 5-23=-586/357, 6-22=0/320, 6-23=756/1878, 6-19=-320211305, 9-15=248/335, 15-19=-747/1036, 9-19=2436/1603, 3-27=400/174, 24-27=-623/1886, 3-24=-254/365, 9-14=-567/1059 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult--160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed; end vertical left exposed; porch right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water pending. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 444 lb uplift at joint 2, 2040 Ib uplift at joint 17 and 581 lb uplift at joint 12. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 239 Ib down and 249 lb up at 7-0-0. 106 lb down and 116 lb up at 9-0-12, 106 lb down and 116 lb up at 11-0-12 , 106 It, down and 116 lb up at 13-0-12, 106 It, down and 116 lb up at 15-0-12, 106 lb down and 116 lb up at 17-0-12, 106 lb down and 116 It, up at 19-0-12, 118 It, down and 129 Ili up at 21-0-12, 44 lb down and 71 lb up at 22-11-4, 44 It, down and 71 Ib up at 24-11-4, 44 lb down and 71 lb up at 26-11-4, and 44 lb down and 71 It up at 28-11-4, and 152 It, down and 194 lb up at 31-M on lop chord, and 311 lb down and 69 lb up at 7-1-12, 84 It, down and 21 lb up at 9-0-12, 84 lb down and 21 lb up at 11-0-12, 84 lb down and 21 Ib up at 13-0-12, 84 It, down and 21 lb up at 15-0-12, 84 lb down and 21 lb up at 17-0-12, 84 lb down and 21 It, up at 19-0-12, 77 It, down at 21-0-12, 145 lb down and 139 It up at 22-11-4, 145 lb down and 139 lb up at 24-11-4, 145 lb down and 139 lb up at 26-11-4, and 1451b down and 139 It, up at 28-11-4, and 399 lb down and 393 It, up at 30-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 , Plate Increase--1.25 Uniform Loads (plf) Vert: 1-4=-60, 4-10=60, 10-13=-60, 26-28=14, 25-26=-14, 20-24=-14,18-21=-14, 18-31=-14 Concentrated Loads (lb) 4mevl.lYw.hnmhlmera'AIbCr9ffi6MtfP56Qilliahf rlStlMNtID1iY�ZaY; W1Ci',®:OYrh¢IeYlbYppu6melmJrmsa�l:rss0e:gv®wq(IBigdbl9:al.imlx4t£hMmeIDznE6erse. OtlnsPsmemEdw@ICI.w!e f ,G6amuatlnasee:ryfleaemaPmma�Pl'.SenPaxv}emm%dmddFd9:u:bwt:ua{�'swesyamnyrymWd@meetrveYnkilg M110nY T. Tornbofit, P.E. H.aeMTo'k'20Nlhan4'diMa 0mWd.ftnb3 t80083 aamgpagrmedfcrudsl.hm,ba:l�e9mutm4aumrwima:.BmtmsmdluNpen.a�prdaPdyY tirdhcavmjrte:pNmatynauudmaa4nrsNa4rWru.dme&l:M1p:Lv.lubuMmipwg,r:va�Fineaao.6edtnRs;mMdrm�atamti,•eA�'vf 44515E. ucle 6ivd. rtnr�al6adrrr(.amyedgnn.:cg7mpmsmMn[➢elms Guy rn�:hr0lMftltlarlug,n,rtlamS�IDvarmemrYaa. Nq.tl damoeml:rmdm@tL Fort Pierre, l- 34946 � (vppildt®10760.I Wvllnsses-AvnvvyLtomEv III,PI. lepndeeivv olaisdommem,ivvvplmn,ispivdi6ihdrAhvN%a nioeepemistien6am A-1 flvAUesses-Amhvari.7emEo N,P.L J.0b Truss cuss ype y A0209279 WRMSCMlb%OBIL A14G Hip Giber 1 1 Job Reference o tonal A-1 Roo! Trusses, Fort Pierce, FL 34946, deslgn@al trass.com LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 4=-192(B) 8=-31 (B) 1 0=1 05(B) 26=-311(B) 14=399(B) 22=-73(B)6=-106(B) 34=-106(B) 35=106(B) 36=-106(B) 37=106(B) 38m-106(B) 39=-1 18(B) 40=-31 (B) 41 =-31 (B) 42=-31 (B) 43=73(B) 44=-73(B) 45=73(B) 46=-73(B) 47=-73(B) 48=-56(B) 50>145(B) 51=145(B) 52=145(B) 53=-145(B) Run: 8210 s May 18 2010 Pnnb 8.210 s May 18 2018 MRek Industries, Inc. Thu Feb 21 14:44:56 2019 Pape 2 ID:Id_OOXyy7618i_TXo1JwHHzefvK-PKOUggd2lFFgCAIFlstRMVeFwX WRJB2rKFyHj_zJurS ...... ndvdnrsamrlm�CnQhwgl2Pd Nkngl.Imb 41L4hm9MEheu 4ilevNsmmlmEeloB,wry wrtrsuwltl*44a�dammpexwla�rurs,oeipfgwp..yngrp.rim+wagmorsyrsmrmmpaoavptlmim�q+ntipnquoomamtr�gab�q,Nugvwoamooh dnTMl. TaMpnnp:u,ueRra,.m,amx¢q Anthony T. Tombo III, P.E. dahnuurshxahcr.Ircamlmtlmo.ha.mo.an.eneyaamhdr.parsq....mmtlnama.meadmtldxrgdhdatmm�mitlmmrdac�vrshamrn,�ucwtrcRmyh,waomas.yaeh�rsq.,�sl�pe a80083 m 4YyMgn=ftnam Wwaftodit,coiaSPdvuall NHgfalsSS/gfIwGA9!puNwnawl MNam"WpallFl bfasbrzgrndtnvdba/6LmhYpe,lmrb4hFinaflnaPmmu,uhv I 44515t. W[Ie Blvd. rMrth14tl11.(dWeTtlge.vA5atldimhhrtlM Nlnu GupifgmrLL4ld Wtlgtryv,uNVSpalgmvtlmrYMq CaPial mmulkei.Ml. � FOR Pierce, FL 34946 4ppip9®1p1p Ai lcollrmsu-ImlevpLpomhelq lJ. lepmdv4ioeo10ndomhssm,wegbr4.isyaGEBediahemlheadleopehminienhov4l leApmsesAvhvvrLlovlo0,li Job Truss I was I ype Y A0209280 WRMSCM1560BIL B01G Hip Girder 1 1 r. Joh Reference o Tonal A-1 Roof Trusses, Fart Pierce, FL 34946, design@al truss.wm Hun: Load Den. =1116 m 5 a 3x4 = 1.5x4 It '— — 31= 4x5 = LOADING(psf) SPACING- 2-M CSI. DEFL. in (too) Udeg Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.80 Vert(LL) -0.11 6-8 >999 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.93 Vert(CT) -0.20 6-8 >999 240 BCLL 0.0 Rep Stress Incr NO WB 0.23 Horz(CT) 0.07 5 n/a n/a BCDL 7.0 Code FBC2017/7PI2014 Matrix -MS Weight: 81 lb FT = 10% LUMBER - TOP CHORD 2x4 SPM 30 `Except' T3: 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 WEDGE Right: 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 2-9-1 oc pudins. BOT CHORD Rigid ceiling directly applied or 6-7-1 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 5 = 138910-3-6 (min. 0-1-10) 2 = 1454/0-7-10 (min. 0-1-11) Max Horz 2 = 80(LC 8) Max Uplift 5 = -475(LC 9) 2 = -502(LC 8) Max Grav 5 = 1389(LC 1) 2 = 1454(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOPCHORD 2-3=-2594/887, 3-15=-2196/826, 15-16=-2196/826,4-16=-2196/826, 4-5=2535/868 BOT CHORD 2-8=-763/2244, 8-17=763/2264, 17-18=763/2264, 7-18=763/2264, 6-7=-763/2264, 5-6=-702/2177 WEBS 3-8=-7/601. 4-6=7/578 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mp4 (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water pending. 4) This truss has been designed for a 10.0 psi bottom chord live load noncencurrent with any other live loads. 5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 475lb uplift at joint 5 and 502 lb uplift at joint 2. 7) Hanger(s) or other connection devices) shall be provided sufficient to support concentrated load(s) 239 lb down and 249lb up at 7-0-0,118 lb down and 129 lb up at 9-0-12, and 118 lb down and 129 lb up at 10-3-4, and 239 lb down and 249 lb up at 12-4-0 on top chord, and 311 Ib down and 69 lb up at 7-0-0, 77 lb down at 9-0-12, and 771b down at 10-34, and 311 lb down and 69 lb up at 12-3-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 , Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=60, 34=-60, 4-5=-00, 9-12=-14 Concentrated Loads (lb) Vert: 3=-192(B) 4=192(13) 8=311(B) 6=311(B) 15=118(B) 16=118(B) 17=56(B) 18=56(B) rmeqrmsmgJ(rub.m'iltlmFVSfSrf{{Ifl'IH[aS1aMA[,16:M�6ta11tl(Ypla'IUQGriaoear6ic lei(h9Pim�mmrttlehsex�MssGrgr&m{IfU4;WbWcrl.1vH 41E4§mr4WMnm otlnsrm.aaainYm).a} WelamNnxXsfiflx,MtmmmtNLL lso4ru Palr hp¢cpa.y+.mtl(t�rnv„0rutlug119nPmmsvrrz�madmlNw¢dsgt,em9nq>u1gYWk,g�6Pesaferm�lyNxN10PW,mbAL iuNsywGrv¢Imspm9Eutr�� MthonY T. Tomb. Ill, P.E. edn,elb rmstgIeN ftft.,klgdmprw.mmMsrANrdra4rmkl8pp�v�• bhrvmddm Kla Kmim 6 kagdew Xt Ae¢n,Mdm@1F alw6amrdmimemttomemr@sbqu lW rdhry"Imbr,Ydgd t80083 Itr4aXWle¢aedremM.Nmes WenrmlCCvlhlvmmelPldmsrtY,¢e9n+nn�SEMhh�eeDo:ld4dfbWdNlmMrmlkpvCPdms llltivibn&emtlebsmd6e:rCEaLa�IvnPr.lmrErvF✓F+PullmsOsdmen.W,s A!* 445t 5L Lucie dwdabrnYl(o(exPlyvMgmbr�mpYfdpmstdv4 dinssrxCpFq'salilNhtitlalPu¢a,tlMtSyRaLpmdmrMl3 N�Wv4YmaemWMbRn. M94 FOR pierce, FL 34946 (appriphl®IDIAA4 rvo11xzus�AmAvvpi.ivm6viX,Pi tepmlvmav ofllisdvmmevl,ivmrlvrm,ispmhlGedri0vmt9e ridrzepxmixixhvmkl6aALnses�AmAmrLiomEolA, P.L Job r Truss I was I ype ry y WRMBCM1SC081L B02 Hip 1 1 A0209281 Job Reference (optional) ••••.•.•=•w.�=.,»�..,...,�y„�......nun: m.nus ma Tuioenra u.elus ma 1azUiamileKlnduslnes, Inc. lhu Feb2114:44:582019 Pagel ID:ld_0O yy61Bi_TXoljwHHzervK-LIYEEWfgXsVORTS2PHmRwjgvLCrBBrenZROnwul3 104-0 -1-4-0 , 94}0 84i-0 18-11-12 1-4-0 941-0 8-7-12 0-8A 46 01.5x4 11 Dead Load De0. = 3/16 in 4x6 6.00 12 4x4 = Sx6 = 4x6 = 1 Plate Offsets (X.Y)— f3:0-2-3,Eddel. t5:0-2-3 Edcel 16:0-0-0 0-0-151 17:0-3-0 0-3-41 LOADING(psf) SPACING. 2-0-0 CSI. DEFL. in (loc) /deb L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.65 Vert(L-) -0.25 7-13 >929 360 MT20 2441190 TCDL 10.0 Lumber DOL 1.25 BC 0.82 Vert(CT) -0.43 7-13 >525 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.14 HOrz(CT) 0.02 6 n/a n/a SCOL 7.0 .Code FBC2017[FP12014 Matrix -MS I Weight 69 lb FT = 10 LUMBER - TOP CHORD 2x4 SP M 30'Except' T2: 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 WEDGE Right: 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 5-3-4 oc purlins. BOTCHORD Rigid ceiling directly applied or 6-11-6 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stahilizer Installation uide. REACTIONS. (lb/size) 6 = 699/0-3-6 (min. 0-1-8) 2 = 789/0-7-10 (min. 0-1-8) Max Hom 2 = 95(LC 12) Max Uplift 6 = -176(LC 13) 2 = -215(LC 12) Max Grav 6 = 699(LC 1) 2 = 789(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOPCHORD 2-3=-1012/619, 3-4=806/675, 4-5=-806/675, 5-6=1017/622 BOT CHORD 2-7=394/806, 6-7=-394/806 WEBS 4-7=-8/372 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Extedcr(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 176 lb uplift at joint 6 and 215 lb uplift at joint 2. LOAD CASE(S) Standard :aqtbe@¢,q'dln,.v@'411CCtIrdull L11J"In{ 6f 0upen 0,S'[6(61 e'ft.d WrCraivfll'@m Ietl,(mppn4nmlaiwnepntrmOny InVdIL d64Rw11.4�4rFIJaev4elh Inv mn�C W L@Nnntmdr WLi mlv@vildik•.ItrbRi0'e'db6w0¢1p67ae(1i.lpegfm}qu9wgMrzeur@ce.vaaatl@,Int��ml�xemgnya,W'plYWlnpitltl bl.uNy Trnlid ir.tivRt lkM.upowvpnnY6ym:mnywoYSp AnMenY T. Toa llt, P.E. ' dn,drat.�so-maspbm.nra>msrauo.,n.o.a..r„medwbedl.l%5my*..mmmvdmm.�udmrubaugdemo+i.n,w�dmmod..r un,dulmsM.srmw.e.lnaor mm.:cddtrr.ny,mnfid 180083 derlY91.¢id@m,y.Nwb.ted.biWd eliInTteddamd@ePe TU lafdq,.Tn. Mkd,bdit MvmEtlpmtpd�lR1@5u,@.mpmd4t tlY dWLn�A@Qx.Ln,A�T•bpeemirm:@.wWm'4.M1u 44515L Wcie Blvd. Ce.iu4hdln6�d,Pdroba,6ghApn�@Nn! Iklnv[eugFggntlil4ldlWallE�m,vinn SlCVFgvwdOl4diq N�v's.tlbmwm4iW bR.l. �(dpprilM®70IEAI4oILoues-AvtlevyLld@he10,1.L&pn2udio, onlisdonmem,iv®tfoi4isploliEnedri10omldlvimee pelmifudohom Ai loo(Uvssef-AmEovtt.iomt@IO,pt r@rt Pierce, F1. 34946 Job Truss Untiss I ype ry Y A0209282 WRMSCM1560BIL B03 Common 2 1 Job Reference(opUona0 A-1 Roof Trusses, Fort Pierce. FL 34946. design@aItn,moom Run: 4x4 = 3.4 = 5x8 = 4x4 = LOADING(psf) SPACING- 2-M CSI. DEFL. in (loc) I/deft L/d TCLL 20.0 Plate Grip DOL 1.25 TC 0.37 Vert(LL) -0.14 7-13 >999 360 TCDL 10.0 .Lumber DOL 1.25 BC 0.72 Vert(CT) -0.27 7-13 >848 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.19 Horz(CT) 0.03 6 We n/a BCDL 7.0 Code FBC20171-TPI2014 Matrix -MS LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 5-1-3 oc pudins. BOTCHORD Rigid ceiling directly applied or 7-4-3 oc bracing. MiTek recommends that Stabilizers and required - cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 6 = 699/0-3-6 (min. 0-1-8) 2 = 789/0-7-10 (min. 0-1-8) Max Horz 2 = 100(LC 12) Max Uplift 6 = -180(LC 13) 2 = -219(LC 12) Max Gmv 6 = 699(LC 1) 2 = 789(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=4175,797, 3-4=-866/597, 4-5=-863/595, 5-6=-11597782 BOT CHORD 2-7=-631/1022, 6-7=-610/983 WEBS 4-7=-286/491, 5-7=-328/363, 3-7=-364/386 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10: Vult-160mph (3-second gust) Vasd=124mph; TCDL=4.2psf, BCDL=4.2psf; h=15ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 180 lb uplift at joint 6 and 2191b uplift at joint 2. LOAD CASE(S) Standard Dead Load DeB. =1/8 in fiR PLATES GRIP MT20 244/190 Weight: 84 lb FT=10% rrewr�manrv'hm..m'nnplmmslwRtaraumrsem¢fmmfmwµ'mmfwarmuarn.m e.hfivpwuvm.soaun.mirm,wwnuhlmlmr,k�r2wn,crtmm�.ninwar. ums�.a,aeammma.mry WeYmmmnmvvil9krutmmCNmkNinrtnu ks4rkmnpl.yuvpegmy meutlwmtnOnQomemPuampanuoih"+minnyallymmosgaansyal„abvmmmmomp acmtmY.apmup ercslmnmi+�7 Anthony T. Tornbo P.E. tlm,amrfonmvfllml6gnmrtrya�Ri4gdmmucmOvui,sEaSagammbYvlUUF.admP9tlmBlmr[mimbNb'fslnktl1141.M4TNtlGe24u-0vNYrseL6,ImsbR596"ilkiMM.YNIvumlkm�imkhl+dlhR 800837lI, 586083 bC+legraprwdrem,m.{f,mevmwsmmoolmpmmrmfptldc,AmMrgpyu�sa.9tdvmm(16tµvdMgmtlu[ImrMommpvtlg6xi RHmasm�eymtl9TectlWctSns&vpe.Lnsb�POpmrmlmstlmCWau,u4n 44515L Lucie Blvd. rSuwltiatlrrefMEegWrusn,fightlllmm%�d�m lkimssd.'r�6gim,YeSlhlapy&,®v.rttnn SyNv6peeaml4LL4. �mD�ms'(kmwmldmtlsllLl. Fort Pierce, FL 34945 (vb�irM®POtdAlRedlmsses-Amivvyl.rombelll, RE Repmdvdieedaivdomvavl,avryh,m,isp,v6itimd�4hemme mnmvpnmisrivehvm A-IRedinsus klayLbet.101. « mss I rues I ype y y WRM6CM15$Oa1L B04G Half Hip Ginter 1 1 A0209283 -- Job Reference (options]) ..., —,..,", 3x4 = '.. 11 4x4 = Dead Load OeB. =1116 in LOADING(psf) SPACING- 2-M CSI. DEFL. in (Ioc) /deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.71 Vert(LL) 0.09 6-9 >999 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.58 Vert(CT) -0.13 6-9 >999 240 BCLL 0.0 ' Rep Stress Incr NO WB 0.76 Horz(CT) 0.02 5 n/a ' n/a BCDL 7.0 Code FBC2017/TPI2014 Matrix -MS Weight: 57 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or4-1-0 oc puriins, except end verticals. BOT CHORD Rigid ceiling directly applied or 9-2-9 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 802/0-7-10 (min. 0-1-8) 5 = 105910-3-6 (min. 0-1-8) Max Horz 2 = 166(LC 8) Max Uplift 2 = -264(LC 8) 5 = -384(LC 5) Max Grav 2 = 802(LC 1) 5 = 1059(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-1157/360,4-5=-294/188 BOT CHORD 2-6=-377/959, 6-12=377/980, 12-13=377/980, 5-13=-377/980 WEBS 3-6=-8/626, 3-5=1170/453 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=169mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed ; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcunent with any other live loads. 5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 264 Ib uplift at joint 2 and 384 lb uplift at joint 5. 7) Hanger(s) or other connection devices) shall be provided sufficient to support concentrated load(s) 260 lb down and 270 lb up at 7-0-0, and 118lb down and 129 lb up at 9-0-12, and 120 lb down and 129 Ib up at 10-10-12 on top chord, and 338 lb down and 72 lb up at 7-M, and 77 lb down at 9-0-12, and 78 Ito down at 10-10-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead +Roof Live (balanced): Lumber Increase=1.25 , Plate Increase=1.25 Unifonn Loads (plf) Vert: 1-3=-60, 3-4=-60, 5-7=14 Concentrated Loads (lb) Vert: 6=338(F) 3=-213(F) 10=-118(F)11=-120(F) 12=-56(F) 13=-57(F) HWq�I@aeEmq�Jrmerm'iltlOfir�6(SEIIPyrflflAtif1Y31(0610[tt(¢SIOMH10a')i(RT.ne6fRhe retlri�yNra�en W,edatlne0lslmsMWdvny(IW,•rim Lls/LL hGIt WuveBnM ne OdwaRMupNJUEegp.m} tlr,Amzmrq+omtr.aemmivaetrw.neuwwplgmxPa.ycmvrhmwner>tlnno rcmemmaampesmvsgsngnemmptrmdmgamsgelmstyemmmmpop.mranu. tatwpwyme,62mmwAvmary mfm, emlmtmigkltry hb,binffiw., tlh P ftor 'rR d femkLg Nl�.Ah�mNNtrB[&E:mimbdka, o11 :i L%c,,aAdm141dm Pstlw6min�stiu`gb@ymrysbm3Sm vibeq dihh,egnCtlgd Anthony T. Tombo lll, P.E. ' bir"w,a,uiremvb. Yl�b>renmtrRmtlmprtmmipitlabmkHlpgrwP,mYCIL+.wevn(ASApNnYdylHtl)GeeMumlmymniprd iMaBue4mpmuo-fObEbLresUmpcimvMgnlePammllwtls5,tu.ani 780083 g4515[. W[ie Blvd. 5vMl6tliiefHvlq„I,p'vf�m,dhdp�mN,et Ninuhuyrqu„4lpibrpmlkspe,e,inu3(Rvips,eEbrMdbq N,gLv9kneemd4mlblln. • Fort pierce, FL 34946 (vppiAb®Hdld A�i lvplinsses-Amlvvpl. iomdvilAP.E. Hep,vkmvv oflAisdvnmem,ivvryty,m,ivp,olilAedxiiEentEe mrittnpe,missiwhvm A�I Hoo(insses-Amdvvrr.ivmdvili,LE. o cuss cuss ype b Y A0209284 WRMSCM7568BiL Boy Half Hip 7 1 Job Reference o tional A-1 Roof Trusses, Fort Plerce, FL 34946, deagn(Oalimss.com 5x8 % 4x4 = 1.5x4 II 44 = Dead Load Defl. = 3116 In LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (too) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.54 Vert(LL) 0.25 6-9 >566 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.82 Vert(CT) -0.33 6-9 >425 240 BCLL 0.0 Rep Stress Incr YES WB 0.30 Horz(CT) 0.01 2 me n/a BCDL 7.0 Code FBC2017/TP12014 Matrix -MS Weight: 60 lb FT = 10% LUMBER - TOP CHORD 2x4 SP M 30 •Except• T2: 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc pudins, except end verticals. BOT CHORD Rigid ceiling directly applied or 7-5-2 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation uide. REACTIONS. (lb/size) 2 = 52710-7-10 (min. 0-1-8) 5 = 43310-3-6 (min. 0-1-8) Max Horz 2 = 207(LC 12) Max Uplift 2 = -137(LC 12) 5 = -137(LC 12) Max Gmv 2 = 527(LC 1) 5 = 433(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-434/146 BOTCHORD 2-6=-267/290, 5-6=-269/296 WEBS 3-6=-49/323, 3-5=-572/520 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind:ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 pad bottom chord live load nonconcument with any other live loads. 5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 137lb uplift at joint 2 and 137 lb uplift at joint 5. LOAD CASE(S) Standard 9cEq'lbaCmnlih�+,hr6-A{IWiir5S61�1alai�iltlWdf6[pP'A4RI6i0Y(UTtrlt'➢qVd'=9ePknietl16�1>a'lmdrclmaneBkirvaOe FdnWOp4dhlmmi.laACtEWncu4eillMierse Ailx�@n'w 9dtlmbNB,m} , YReiao9�rknYmMmlbhIDrmY,Nt LLm4u Bmpf@nePr.Yem6f6mzl.h Wng1N„p mesaymaY4ldmm�a!"�4mN"'�Cft&M4dh�ejelm�dgmtlwhII9m¢,dn9Fi.lYMpmuyW¢4gmlownAtlOp Anthony T. Tom6o I[t, P.E. dadkalmimrgYvr6Eempd,ledmeUm.te OmePrebied9mebMlfa94diP.mR,matl6e6CtrCaILgNMaY4e3R1.1k9PmltlbIDldw6eYu,d4lmc®lG9hc'i+mBeCKWueWN�iY9hGrtMmdeld r^80083 dt�xgvngamrmn�.m=xiwmmmumr4mAmmdral,Imodmtr.GgtwPmsimfexmma(ml,+plVilmgmmSeA.m,mrmampmlpam nuatnsemi�aunememdauevdupv.i�ompuyavmlm:xsmmm,aYsr 44515G Lvde Blvd. .* ffimdAnoam'minnm.imyrymprxWAr.lmsn+aramm lvrCtdAWyk:gm,ulnuliCmaisndmYdLp m ...kNcmnd. Fort Pierce,R 34946 (mbriPb0IDi6bl Wm1lresse AvhmopLlmm7nl0,Pt Peprolmmmv dtlisdmmmem,immgfmm,isproA3uelriemmMemdOempenmsuwhmm A -I Bmdlnsm Avffi., Tod.lk PL i Job Truss NSS ype ty y WRMSCMIAOBIL BO6 Monopitch A02092&5 2 1 Job Reference o tional e 1.5x4 II 4 3.4 = 1.6.4 11 4x4 = LOADING(pst) SPACING- 2-U CSI. DEFL. , in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.46 Vert(LL) 0.06 6-9 >999 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.26 BC 0.33 Vert(CT) -0.07 6-9 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.42 Horz(CT) 0.01 5 n/a n/a BCDL 7.0 Code FBC2017ITP12014 Matrix -MS Weight: 62 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP Nc.2 WEBS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc pudins, except end verticals. BOT CHORD Rigid ceiling directly applied or 5-1-5 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 52710-7-10 (min. 0-1-8) 5 = 433/O-M (min. 0-1-8) Max Horz 2 = 264(LC 12) Max Uplift 2 _ -117(LC 12) 5 = -200(LC 12) Max Grav 2 = 527(LC 1) 5 = 433(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOPCHORD 2-3=-605/196 BOT CHORD 2-6=-481/483, 5-6=481/483 WEBS 3-5=-549/547 NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads. 3)' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 117 lb uplift at joint 2 and 200 Ib uplift at joint 5. LOAD CASE(S) Standard e,mprmmx�mmm•f.umrnmrsfssuQyymautaaemmmcncmonronoyaasn:urram t,ryaaPra„emd�am.mla:oxpm,.gtncdmu.�rl.tem4rim�m nma .x oart,cb.marexmloe.xy Y:Iaaesm,rkmdIDmrulmmtdhbmmb s:eLma�mf+.N•4m�hbvfs'.msr9xgmanpoen..vpua[mrm:oedegasgaymaaymmx:gam:gemurymlwmtu up.mvmt w6,pwyasmeaAamasyacfaq Anthony T. Tombo III, P.E. ' dnetlk:Im,mapbtl'ulhmrt:IwbNl[mUm[b:O+ei,clatdyfebWtryUegs,bmmngb0(,4Celm4mfa'@(M:m1R1.Thgyntltl¢:IOldmmtlxetlmrmebl�brt,'eym�e.mw'L:vodbmil3mbrt!pa:0lrytl 280083 mmugpnbmdlam[s.AcxxsmmsmIDodmr�+smpatlasrtmrangtx�.zfe:gth emlmlixeaeapmanuve�a mamrmntp�vuaa.:imtmaaeusiaes[mus:duye,umksn5�smrm,vsav,eus, 44515t. Lucie Blvd. . ftuwldtlire4Am9dWxbMblhtllimxb Jd tminssgvafqbx,hADlmleYy&.pa,alnnSrmafgmdxrlAy N�tlaJtrmxexlddbRtl. Fort Pie(Ce,R 34946 (vppipm®1tl1AA4lvetlmsses-Amlavp7.iomhvlq Pi Hepmdubi WISis Avmnem,mm/mm,isprohildeArdAemkr mirtmpe�siwfivmA-I Hootbunes-AmAvvr7.7vmAvm, Pi o mss cuss ype y A0209286 WRMSCM7560BiL CJ7 Comer Jad< 10 1 '� Job Reference o tional A-1 RWI Tmsses, Fort Pierce, FL 34 b, aessgn(mallr .WM 49 LOADING(psf) SPACING- 2-M CSI. DEFL. in (loc) I/deft L/d TCLL 20.0 Plate Grip DOL 1.25 TC 0.18 Ven(CL) 0.00 7 >999 360 TCDL 10.0 Lumber DOL 1.25 BC 0.03 Vert(CT) 0.00 7 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 4 n/a n/a BCDL 7.0 Code FBC20171FP12014 Matrix -MP LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied or 0-11-11 oc puriins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = -5/Mechanical 2 = 18110-7-10 (min. 0-1-8) 4 = -21/Mechanical Max Horz 2 = 42(1-C 12) Max Uplift 3 = -5(LC 1) 2 = -71(LC 12) 4 = -21(LC 1) Max Grav 3 = 12(LC 8) 2 = 181(LC 1) 4 = 20(LC 8) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 5 lb uplift at joint 3, 71 lb uplift at joint 2 and 21 lb uplift atjoint 4. LOAD CASE(S) Standard PLATES GRIP MT20 2441190 Weight: 6lb FT=10% eexq Fm4ny51meem'41npf➢'196('ffll�pg6et t9Yi1@6tIiC65lmtOtl(�sl'IeaCE.➢eefrPh¢textWPW®omadMNn.Oulmv En'Pnn9llC';ami0¢lLle�nllydemAxl%ty �m�.mmdnM WeYo¢N,leetilIDGml6eb➢d¢k Hd baLru Mp6pmxpa.Spmey[r„Sd buJnrR➢JePnM¢.°'A.dbFd'ssutlxFhm•4nµmdOgsimlrsydm Wjeimsl;admMldOtlr.dut%L lbinpwn�h2si¢tl4n.¢LL^J102 q Anthony T. Tmbo III, P.E. mlmdWLusb WlulEybBesWr rlm0.2mO+aivm�Rtlhtl¢blot!NGn�.OmvmCtl4rd.6eCelm�f.Y4MecdWLMP,,xdtlb RltlgrepuedminscWartbLKsffiir-lM6ual Yva3sFflhN,+WSAiid 280083 tuepvmq,¢mummx ev¢evmmuamnmmpmasaepum�amnupgr.gnseml�s,.m.@ypYmm4amrcaomermvm�et¢d�➢ueasemµnuvasafma�eburesoecpe.lmvvnmsganalwr:.dm...b: 44515L tucle Blvd. . Luis aLn�+r>J dlter�l9edMrY"m�9hmpbsYW�nrinu0eayfgmsGlmmlaY;Bespm,xlms5rna[gaeedmtk]9g Ngmxlbm¢emld�uml. Fort pie ,FL 34946 m (vppipmmpDlAA�l Aevlimsses-AmAvepi.ivmhv Dl,pi. repevdemovd➢isdvmmem,ivvv/Iwm,ispmh5ircdenbvm�e¢Nhvpemisdmhv¢A4 pvdinnm�Av%vvri.lvmhvm,li Job Truss Truss Type ry WRMSCM7560B1L CJ3 Comer Jack A020928] T 1 Job Reference (optional) „G., gm c'..., 2x4 = LOADING(psf) SPACING- 2-M CSI. DEFL. in (Too) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.18 Vert(LL) 10.00 4-7 >999 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.08 Vert(CT) -0.01 4-7 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n1a BCDL 7.0 Code FBC2017lrPl2014 Matrix -MP - _ Weight: 12 lb FT = 10 LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- LOAD CASE(S) TOP CHORD Standard Structural wood sheathing directly applied or 2-11-11 oc pudins. BOT CHORD Rigid ceiling directly applied or 10-M oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation Quide. REACTIONS. (lb/size) 3 = 64/Mechanical 2 = 212/0-7-10 (min. 0-1-8) 4 = 23/Mechanical Max Horz 2 = 82(LC 12) Max Uplift 3 = 43(LC 12) 2 = -63(LC 12) Max Grav 3 = 64(LC 1) 2 = 212(LC 1) 4 = 43(LC 3) FORCES. (fib) Max. Comp./Max. Ten. -,All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. IT; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads. 3)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chard and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 43 Ito uplift at joint 3 and 63 lb uplift at joint 2. Fmqk,utmgtlrmSr6'i{IidF11IDa(fNa1�31nBtlf{i44:111[J6f01JtljM91i01[ilnirfR6m iatlihYpiss lmr/mlvnaO,imipn4pmq[Ift;.ct�L!oiLtahgtFMm�&XkFe ae DilnskeruffidroaelC6,wry �tl wlamdGdmikbPBak,tl4 ivelm�kapb apr.ye to rmudugminporo.m.�tlmpaamrgst~,yrtgmemrymminpvu6�ujotnssymmmltaep, ceulmL�Pnn>inmaegmltn,w:l3p Anthony T. Tombo 111, P.E. ' odm� dW6,kmk"h bZ1206! dl*() e&orn$c dymak Wit, miPe.a6msd4k0[,a�Mau, adknafimtl Pnhgp aaaaamm.avmealmcatl m+'+grsigr.YA�tm roievatildikGnµ. rt s80083 kkYg4egad4u,pv.IC¢kmnmehinglnF smipNdml ftwdg4'um soggM 'W'O5 4Mciga nim!&'WW.W1 Nmitzerymatlam elkamELLm&ura.im54nAiepm¢iO,uVmhs4mm 4451 St. W[Ie 0IW. Re,lul�ditai�dN�dNmas,¢ihd�ia,ddrc11ie1msNgFg4m 4101hkkain. r,inn5!4afquvtlm!bE'vq N,q::WtrmeamitlmlaRN. Fort Plera, R 3491a fopililN®P0IA 1IooHresses-AoidtloridomCtl OLPitepmlodiooefdbiommm,ivve[ivrm,is RotiAn<drtlhedPonmktlpemiui.h.A Dvd%ueo- Avmotlgl]omlolO,Pi a mss cuss ype ty y A02B9288 WRMSCM156001L CJ3B Comer Jack 1 1 ! Job Reference o tional A-1 Rwf Tmsses, Fon PietCe, FL 34946, Uesign(Aait ss.wm Run: 8.210 s May 18 2018 Print: -- s May 18 2018 MTek Intlusfries, Inc. Thu Feb 21 14:45:01 2019 Paye 1 ID:ld_00XyyT61BI_TXoljwHHzeNK-mH9R['gnlyJxBd4OTc3 ckivpiOZnaTWf2OBzfurO 2-7-7 a' r 2-7-7 314 = LOADING(psf) SPACING- 2-M CSI. DEFL. in floc) I/defl Lid PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.11 Vert(LL) -0.00 3-6 >999 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.10 Vert(CT) -0.00 3-6 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Hom(CT) -0.00 2 n/a We BCDL 7.0 Code FBC2017lrP12014 Matrix -MP Weight: 8 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied or 2-7-7 oc purins. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1 = 9510-3-6 (min. 0-1-8) 2 = 67/Mechanical 3 = 27/Mechanical Max Horz 1 = 52(LC 12) Max Uplift 1 = -13(LC 12) 2 = -47(LC 12) 3 = -1 (LC 12) Max Grav 1 = 95(LC 1) 2 = 67(LC 1) 3 = 41(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Extedor(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads. 3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-U wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 131b uplift at joint 1, 47 lb uplift at joint 2 and 1 lb uplift at joint 3. LOAD CASE(S) Standard re�rem<ehsse.m•ume:¢m¢(uu�araummlmmemrmlaaiimlruelcr,¢:aal•m. t�eltrenlm®mnsdmedmmmtsmis�mMal911mm+rltmvRrfmama+ivmm,. aussms.mmdnalooaq walm rnruramm.mmmupax,dd lse4ruw4M�m0+.km�apraz�ugmarztwmoe�mJmr�e:�omd q'+mYonydaysmam:pdmveyeinnpmlummoary.damttYingeualnm.6symrrm.ecrmp Anthony T. Iil, P.E. dmAW lm�murtYmlumnWa3W dm0.,n.mOml:eemd4x9umlrJm9Avis,mhmAntlmW.0eCd6b0pY'�1MariMl.lb&NYM1WdmFJlnedmlmsmAaal1r8b1nER dh®9�1dhmMmviOd 38008360083 mmrlmsmmdrdnm. m.arm®YmIDadrspam,mllenrvnnmaucquersemmlea.eo9;w}Wroaapinaralwrt�nmspo,np�m+en.:azmnmttaumaseFun�ompa.trmwpaganmrwxmama++s 44515L WCIe Blvd. RmwmWsdlf.fm.N ePdnm Y.^agbrANmrmAd iYimska}[grmlrlp1m16Yc{Eugm,ulassiltatq'am6gM�y. N,getl�tmmmlddmfil. rOR Piow,R 36946 �(vppiphl®}AIAAlrvvflnsses-lslhvvyi. ivmhvlryr.E Aepmdomiovafllisdooumeem,ivveplmm,ispwASdrdrvhcmmerrimvpemisJmhvm A�I BedrmcerAvl6mrT.ivmtvlll,Pi Job rues I russ I ype tv y A0209289 W MSCMI5BOB% CJ3L Comer Jack 2 1 Jab Reference (optional) A-] eet I russes, Fon Pierce, FL : rub. aesign(ma tru s.com + Run: 8.210 Feb LOADING(psf) SPACING- 2-U CSI. DEFL. in (too) Udell Lid PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.18 Vert(l) 0.01 4-7 >999 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.12 Vert(CT) -0.01 4-7 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 7.0 Code FBC2017/rP12014 Matrix -MP Weight: 12 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied or 2-11-11 oc pudins. BOTCHORD Rigid ceiling directly applied or 10-M no bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation aulde. REACTIONS. (lb/size) 3 = 64/Mechanical 2 = 21210-7-10 (min.0-1-8) 4 = 23/Mechanical Max Hom 2 = 82(LC 12) Max Uplift 3 = -43(LC 12) 2 = -74(LC 8) 4 = -29(LC 9) Max Gmv 3 = 64(LC 1) 2 = 212(LC 1) 4 = 43(LC 3) FORCES. (lb) Max. Comp./Max. Ten. -Ali forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; parch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurmnt with any other live loads. 3) •This truss has been designed fora live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 43 lb uplift at joint 3, 74 lb uplift at joint 2 and 29 lb uplift at joint 4. LOAD CASE(S) Standard mrmr m,�y,,,o.m•uru:nmrsryualarautuurmrnmcnmiorlmalun:.m:urro-..t.eleupiamem.aaam..mnm,eao„nmymcde.wrt.t�anitle.ur>4nw.,,u mmob.�sex.am®..y MlklpmfiiWroahrs(4,bapbM�/4Isa4M1t Mgv6mapa.IlvuErbPa'Fmutle.la]nFvmvmmn'�tlmx4n�b4mv�IVNn4ip0(hMMkfJCe�sy,InvbhloblWplr.vie&I.lblxpnnalnAY@aim-Mvtsr.ElPn Anthony T. Tombo 111, P.E. drvtLa lmrbmk'SaybAiuN'dW 4mp.,v.h0evlic6rCtl¢aC,lvlfAR�..6m!evJb Af.4C.ltlrbigCAMee11141.INQl,m'db0ldahq,ntlNrmtt'b691�e4imW.Ma9Lm.lYad3UAYdnYmOE%9 380083 h taxgfnynwfmra.ic.nsstmamtxmmrmmmnJtlm,Imdmq NrmmYgcs mpdjpinxeM1udlwmvkmfbywpava lmeeanLmpvmM�mprvt4lvrG�pa.[mru puyavmlmrYacar4vpu 44515L LUde Blvd. . ramlulGtlhafmaeq,tlyos.0{M1dponYgrtl ielmvdu;t[gam6NthnngL .vtnv Sryaafgmler�lV agbaabmmnl6s1a1R1.- Fort Pier2, FL 34946 (opPirM®1p16A l taflmsse-Avnvvrl.lovdvl0,lJ. lepmlvAuaOisdvrvam,bvgiwq isprvi3ded.itteNRnNkrpemissiwhan4l trv/Lassev�AVlEvvrLlomGO,lJ. Job Truss I ruse I ype tY Y A0209290 wRMSCM1560B1L US Comer Jack 6 "1 V Jab Reference o tional A-T Roof Trusses, Fort Pierce, FL 34946, design@atwss.com Run: 8.270,, May 18 2m8 Print: 8.210 s May 18 2018 MTek Industnes, Ine. Thu Feb 21 14:45:02 2019 Pag9e 1 ID: Id_ OOXyyT61Bi_TXoljwH HzetvK-ETo14uiKb5?pw5mpe7_rcmu RLyh?701jiAPcxeziur? -1-4-0 4-11-11 1-4-0 4-11-11 2x4 = 4-11-11 LOADING(psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.37 Vert(LL) 0.04 4-7 •>999 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.29 Ved(CT) -0.05 4-7 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 7.0 Code FBC2017/TP12014 Matrix -MP Weight: 18 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 SOT CHORD 2x4 SP No.2 BRACING- LOAD CASE(S) TOP CHORD Standard Structural wood sheathing directly applied or4-11-11 oc pudins. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = 122IMechanical 2 = 278/0-7-10 (min. 0-1-8) 4 = 48/Mechanical Max Horz 2 = 123(LC 12) Max Uplift 3 = -81(LC 12) 2 = -73(LC 12) Max Grav 3 = 122(LC 1) 2 = 278(LC 1) 4 = 77(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) `This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connexion (by others) of truss to bearing plate capable of withstanding 81 lb uplift at joint 3 and 73 lb uplift at joint 2. Ym9f tvmkwt 96Ia'ys9lllfiYf(]'411r450m' alrfe4TJ&:4(Rlam➢wd[h9ppWmdnfemn•rslrmpnplm.q(IIX?dhLlmltisA&r1.hNv.4xlHn me hWrCstr9Cln4maay 'Ne,oahnm'll Wel<m!hrrhhs6tllbralYPem9bhWd AveimiDnlyfrrav(If.Sµne(tg4Mffiw9npPNDnpnmseaeymtlmpNvtlrtlegXalgn�06Ytbmh:ytlOeRjrNniy141wNNDmD.ohW.LmLslpnmlllllrnh@pml"vutwlA6T Anthony T. }II, P.E. / \ drwtlbifmrmmtralfidkmmlmtdiYAtlmPw,eOnrtie%serlS'mamtmYwlnw.saenreaamn muutmkmk�4hlabmeRlMgmtlimlMda6nrnamrms.5ia1 4MF.emaiuW x�ilaa Lreq+na�e 03 II8060083 \1 e.mxgDriq®drmvmmmam�.mmommlimazmp�.nnmweyugmmrye.vcm;�Pa¢agtnmvun..weeHm�,ipa�miePvvvrrq=uanmmmeenumrdape.imzoepuganmfrmirx�i�,.1ss 4451St. Lucie Blvd. l/� a#muW dlPxre4mMdrA h'm94tl Nmvmdcel ihlnvbpy[yazalilDim[1Mrylcym,elnn SP9aFgnwOmrbLeR lDa}tla9bvwmldal61M11. FDtPierce,R 34946 � (ohrirhim PDIIA�I BvoHmaes-AvmveyL7vmAe111,P.E. Beprodvaivvaftlisdmumem,iD vghr�isproh0dedvit9omkr.rillevpermissinhomLlBWrrvnm�M%wyi.renklll, PE Job Truss I mss I ype tY y WRMSCM159081L CJ5A Comerdack 1 1 A0209297 Job Reference optional A-1 Roof Trusses, Fort Piers, FL a4946, cesignopainuss.com Run: 8.210 s MaY 4-2-018 2018 Print 8.210 s May 182016 Mi-rek Industries, Ina Thu Feb 21 14:45:02 2019 Papa 1 ID:Id_0OXyyT61Bi TXoljwHHzetvK-ETol4uiKb57pw5mpe7_mmuTVyj1701jiAPcxeziuO 1-4-0 4-2-0 r+c 4-2-0 LOADING lost) SPACING- 2-M CSI. DEFL. in (loc) Well Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.23 Veit(LL) 0.02 4-7 >999 360 MT20 2441190 TCDL 10.0 Lumber DOL 1.26 BC 0.18 Vert(CT) -0.02 4-7 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a We BCDL 7.0 Code FBC2017/TP12014 Matrix -MP Weight: 16 Ib FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- LOAD CASE(S) TOP CHORD Standard Structural wood sheathing directly applied or 4-2-0 oc pudins. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = 99/Mechanical 2 = 25010-7-10 (min. 0-1-8) 4 = 391Mechanical Max Horz 2 = 106(LC 12) Max Uplift 3 = -66(LC 12) 2 = -68(LC 12) Max Grav 3 = 99(LC 1) 2 = 250(LC 1) 4 = 63(LC 3) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads: 3) `This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 66 lb uplift at joint 3 and 68 Ib uplift at joint 2. erkyrk¢.b nu,,.m•Nuornacsl'Iwa'tumuleiurncmwarmrm(wlm�smarmm reh+saromr*,a,ee,.mnm,w,yn,.nln'e;de.m�l.l�,crtmna.arrn ¢r mwuem.arutl¢mlca,m7 mGammrkk ac6mttrmtw¢e,m.brurvE¢ipfp¢Psycw>tnpcumn�mi¢pnmre.¢ryv¢dmpmmmawk�kfe4�>trvmtrwpawsepermrgad¢brmo }.grmt raary¢n.rms,bxGmrmbrrtimr Anthony T. Tombo III, P.E. AI! 380083 mkky0¢m elrmru. g4515G Lucie Bh'd. dsdnutzrtlhr6�w•+n¢b. sghdir,mbrone ml..¢[q[gmrirrmr,ramrw,,,¢u,sst¢aa6rnvdmlanny magawm re¢feaeml. Fort Pierre, FL 34946 Q iPRpM02r6Alhxffmsses AmdarylJom6o 19,Pi tepnlornavcftlis6ommia,merrlom,ispro606rdwi%emrhevmrtopermissiwhom A -I B:olinsses�Aerkmyi.iem6o1142i. Job Truss ruesType ry y A0209292 WRMSCM1560B1L CJSC Came, Jack 1 1 .y Job Reference o tional A-1 Roof Trusses, Fort Pierce, FL 34946, design@altmss.cam Run: 8.210 s May 18 2018 Pnnt: 8.210 a Ma 18 2018 Mffek Industries, Inc. Thu Feb 21 14:45:03 2019 Page i ID:ld_OOXyyT61Bi TXoliwHF�zefvK-igL7lEjyMO79YEL4CgV48ZRcrMObsTHtxg89T4zmr 4-7-7 4-7-7 3x4 = 4-7-7 4-7-7 LOADING(psf) SPACING- 2-0-0 CSI. DEFL, in (loc) I/dell L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.38 Vert(L-) 0.04 3-6 >999 360 MT20 2441190 TCDL 10.0 Lumber DOL 1.25 BC 0.33 Vert(CT) -0.04 3-6 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 HOrz(CT) -0.01 2 n/a n/a BCDL 7.0 Code FBC2017/FP12014 Matrix -MP Weight: 15 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- LOAD CASE(S) ' TOP CHORD Standard Structural wood sheathing directly applied or 4-7-7 oc purlins. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1 = 169/0-3-6 (min. 0-1-8) 2 = 121/Mechanical 3 = - 48/Mechanical Max Horz 1 = 93(LC 12) Max Uplift 1 = -27(LC 12) 2 = -83(LC 12) Max Grav 1 = 169(LC 1) 2 = 121(LC 1) 3 = 74(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. NOTES- 1) Wind: ASCE 7-10; VuI1=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 27 lb uplift at joint 1 and 83 lb uplift at joint 2. neme1M= '1A*bTD.hu i111� r[p6*.4allYllnIPIL'�8rai99fYl'fnc ie!h4v@r ev9nmrzfem Ali¢rr1uR�6�mrI�B7dhLfmlttaf�giLNum9an &,V.riGtlnn.nv wrelmurmv dIDlrrdhmCpmY�94 Asoururoy6puwp•ymmp5p.�mWnvraonmaWve•ry".mx4M@tlmndgkmhp ymnarrtraWwdmuyemue*nxwbIDOMday.�ba�pwapnmurcymmm,vaap 1ffd WO hr pdrypmY T. P.E. / \ dnedNffi b•dMdo35Portye.hWEh Owr.AaO•utinFmYdrY�•OeNlpgAa4a.m4a[mdbOCb6a1!KMatl9M� IIIN.1bWmeIdISIDOnImRYmtlLMshK9r�`+Cs�eA26EvdkvSi�Ogbn�p�ild/i 80083111, II90083 \\1 ��kgangmdcee,a.mebmm�eemBdb@vEtrsnfpaJvevX••mrgteeym�Aeryhkemv(m:ld4am%WdswaeebmmM1@om@tiv¢mlatiusenymalr.�demeemiasAvpe.ims9m5+upenmrwrmn•muwxe 4451St. Lucie Blvd. 'lmm+�m+InrmWm%Apam•+m+rkmrmvseNrot t6lm.duy tgd�¢rm6umqurym.muf@m6pnaor�m4 Nw�mm@mmem�mdmnu. Fart Vme. R. 34M6 l//■ � (ep)Ti1b®PU16Ai l•dlmsses-Imlvvpf.rvmlvOl,P.E.IepfvdvNvvFlEispvmmem,ivvrylwgispwl0ue!•i%cdMrmdilevpmm�uveM1vm A-1 BvdinueaAm6evpLpvmlvOl,PJ. Job Truss I was I ype uty My WRMSCM158081L G15L Comer Jack 2 1 A0209293 Job Reference (optional) ' A-1 Roof Trusses, Fort Pierce, FL 34946, design@albuss.com Run: 8.210 s May 16 2018 Pnnt 8.210 s May 18 2018 MTek Intlustdes, Inc Thu Feb 21 14.45:03 2019 Page 1 ID:Id_11OXyyT61Bl_TXo1jwHHzefvK-igL7lEjyMO7gYEL?CgV48zRaAM?ssTHtxg89T4nur • • -1-4-0 4-11-11 1-40 4-11-11 R 3x4 = 4.11-11 LOADING(psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/dell L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.49 Vert(LL) 0.10 4-7 >563 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.44 Vert(CT) 0.09 4-7 >648 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 7.0 Code FBC2017/TP12014 Matrix -MP Weight: 18 lb FT=10% LUMBER - TOP CHORD 2x4 SP No.2 SOT CHORD 2x4 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied or4-11-11 oc purins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation Quide. REACTIONS. (lb/size) 3 = 1221Mechanical 2 = 27810-7-10 (min. 0-1-8) 4 = 48/Mechanical Max Horz 2 = 123(LC 12) Max Uplift 3 = -81(LC 12) 2 = -102(LC 9) 4 = -51(LC 9) Max Grav 3 = 122(LC 1) 2 = 278(LC 1) 4 = 77(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psF h=15ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Extedor(2) zone; cantilever left and right exposed ; end vertical left exposed; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 81 lb uplift at joint 3, 1021b uplift at joint 2 and 51 lb uplift at joint 4. LOAD CASE(S) Standard Fvrq'PomCmnl!llmMl4'n IDD:IYm6(NI�1al]LId6Rh('JG113fUfiJijlp4'i2;p4P,{lopfll'mv.IaAftrGplm,aamdMrtnvtlslmspng,lmq(10.?Nh4tm1.6sh4rEtEvemLxltMnv OtlasCma09tln4M.aj WnmxmrhvsilffiheedmaP.dhbNd suuwoecnhrnaN.Ymm!r!?m;a!!wnnluG,rvaamnv�dapa!w,mmsmgaywmpmalegdasepeumgpdeamoary.caxtn[bt�pmn.µo.ugorawrrn� Anthony T.Tombo Ill,P.E. ' dm�tl4s lmragbYAhartslnvh'T,daAaa@IvfscfahtlirbinlfW9uga,vYnv!UdaB[a Kdlhhd MYrsMe¢10.1.Ibgaenda NOedmkhn�dalnrz�,fiyttltq!asP.ENlmavlM@lilflbhngaNipld 230083 baYglm¢ad(aaa. Nvhsvimhalaodal!amsmgwJ.mfdauYq(eepavgenmlc9;pmalklvrdsYlmmnmemlmdpfu llumua6mKxwumfpwdaLnsAgm,LessoerpngevmimslcGmv,n.!s M515t. Lucie Blvd. !mMul6ntlflv4lbg,tl5vhr!ar„dlpmaYrct lblmsghg(µm!hlhtteGYy Wgn.rtInJSPieigewpmlM94y N�Livslbnvenlm�6Rll. • from Pierce, R 34946 fvppiphl®1tl1AA�l lvvtlmsses-AmlvvpLivmAv0l, pJ. Pepmdv4ivvolltislvmmem,uvryfmm,isp!vhe&dsiiAcNlhe•nllevpeimisuevhem A -I PhvfLnm-AmAwpi.[vmpvN,PJ. Job Fruss FruSS Type ty y A0209294 WRMSCM15BOBIL US Comer Jerk 1 1 y Job Reference (optional) A-1 Rwf Trusses, Fort Pierce, FL 34946, design@1alGusa.wm Run: 8.210 s May 18 2018 Pnnt: 8.210 s May 18 2018 MITek Indusues, Inc. Thu Feb 21 14.45:03 2019 Page 1 ID:Id_OOXyyT61Bi_TXOI MHHzefvK-igL7lEjyMO7gYEL?CgV48zRatM7XSTHbrg89T4zwr_ -i-4-0 5-8-0 r 1-4-0 5.8-0 2x4 = LOADING(psf) SPACING- 2-M CSL DEFL. in (loc) I/dell L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.51 Vert(LL) 0.07 4-7 >897 360 MT20 2441190 TCDL 10.0 Lumber DOL 1.25 BC 0.40 Vert(CT) -0.08 4-7 >803 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 7.0 Code FBC2017rTP12014 Matrix -MP Weight: 20 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 SOT CHORD 2x4 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied or 5-8-0 oc purlins. BOTCHORD Rigid ceiling directly applied or 10-" oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = 141/Mechanical 2 = 302/0-7-10 (min. 0-1-8) 4 = 56/Mechanicel Max Horz 2 = 137(LC 12) Max Uplift 3 = -94(LC 12) 2 = -77(LC 12) Max Grav 3 = 141(LC 1) 2 = 302(LC 1) 4 = 89(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult-160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf, h=15ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads. 3) `This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 94 lb uplift at joint 3 and 77 lb uplift at joint 2. LOAD CASE(S) Standard te,q.nvrevvwaxntl.mY.nsri�nryula-ymaum0.ato¢meuemuM(C7s+,uncaaiLarmn Sefie�rr'�memwrt6eanua:inn&sak;�W11W',rahie:nlnvmmrlaems�hkem odma .iocninktor,eir //_�\ wtawsai' ;rtmb;wmmmoekn[i. uvurs¢elofyenp;.yevmamY nwagIDSsgmnnempaaeerrMuestlq'+mlq�;waOChtrmin4ahsgemnkymire!!➢oW.mnmL ibMgvnnvFmlapm9exsvmJmtl pathpnY T. t[I, P.E. i \ eamdM4nsfv mlln%09ebrtsW+0aWa60ns.0ePM;e.4¢ed4debinlfnr LniR.a@Moab OCMl:�bhNMY;WeM0.tib r4";nitlhIDldu.RYaedOetme�5lka'Nsa9e0R8dmn1trW9dfldbnyaddfid 280M80083 ■U\ uebxgwgnwLmm.wex;mwehmoenbrmmmpaamsdmbwqugmnSrtmstvwH�µmo-e%mvawLn,durmawLonlpv�n➢uam;b�;gmtamn�asndeun;oevwetmvml,6paremlm;nmrmn.ew; 44518G Lucie Blvd. e5eeluldwJtie4sclgWrPasnsq„alpaq;hNreL ikrnuksq[q'm,;rCtbb%yPaga,xlmsSiRa(gzvdoiNby IIIp3ffi9kewmL3m.4C1lH. W Piece, F1 34946 6piripdt®7dld A'I lovtirmes-Av0evr7.lemAv01,P2 Heprotadiev ofMispvomem,mmrim¢isproHaOeEwdM1vmMewnikvpe�mi;dxhvv A -I Hevl4vsus Ad.Iy .runtvHl,P.L cuss cuss ype y WRMSCM15itOB1L HJ7 Diagonal Hip Girder A0209295 3 i Job Reference (. tonal) i 3x4 = 1.5x4 II 3x4 =' LOADING(psf) SPACING- 2-M CSI. DEFL. in (too) I/de8 Ud PLATES GRIP TCLL -20.0 Plate Grip DOL 1.25 TC 0.59 Vert(L-) -0.05 6-7 >999 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.53 Vert(CT) -0.10 6-7 >999 240 BCLL 0.0 ' Rep Stress [nor NO WB 0.40 Horz(CT) 0.01 5 n/a We BCDL 7.0 Code FBC2017ITP]2014 Matrix -MS Weight: 43 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-M oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation nuide. REACTIONS. (Ib/size) 4 = 159/Mechanical 2 = 442/0-10-6 (min. 0-1-8) 5 = 274/Mechanical Max Horz 2 = 182(LC 4) Max Uplift 4 = -107(LC 4) 2 = -180(LC 4) 5 = -64(LC 8) Max Grav 4 = 159(LC 1) 2 = 442(LC 1) 5 = 274(LC 1) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-1 1=-7341174,11-12=-684/191, 3-12=683/181 BOT CHORD 2-14=266/679,14-15=-266/679, 7-15=266/679, 7-16=266/679, 6-16=266/679 WEBS 3-6=-717/281 NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed ; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load.nonconcurent with any other live loads. 3)*This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 107 lb uplift at joint 4, 180 lb uplift at joint 2 and 641b uplift at joint 5. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 77 lb down and 90 Ito up at 1-4-9. 77 to down and 90 Ito up at 1-4-9, 36 lb down and 41 Ito up at 4-2-8, 36 Ito down and 41 Ito up at 4-2-8, and 66 lb down and 88 lb up at 7-0-7, and 66 lb down and 88lb up at 7-0-7 on lop chord, and 121b down and'40 lb up at 1-4-9, 121b down and 40 lb up at 1-4-9, 16 Ito down at 4-2-8, 16 to down of 4-2-8, and 301b down at 7-0-7, and 30 lb down at 7-0-7 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 , Plate Increase=1.25 Uniform Loads (plo Vert: 1-4=-60, 5-8=-14 Concentrated Loads (Ib) Vert: 11=57(F=29, 8=29) 13=-74(F=-37, B=37) 14=46(F=23, B=23) 15=9(F=-4, B=4)16=-56(F=-28 , B=-28) rq.raa,.m�µme.m•unu,rum¢MIa'tmurtaunPenmannufaxalwcrmumn>tamre,.rwe.sn:eaasnRenn�,,,oamme•4t¢e;dm+mari>:�nnmw„mnaaer:: ¢+ne,a®.tr meae➢o.xr mt�tmzm!'+smmdnamm➢mM.ru.ue»usophyn(,a§mgws,4uluglmaPe xe.mimaampasssviymrymwmuntrmkvg�umsyetnayminm➢owk�!^iht minpnn.pav6egmau�ocJmT Anthony T. Tombo 111, P.E. dmd4r tn:tk'1Wb'am,urywtintlm Pm.mamiirductlrpdumld'feyppip,mm�FtdmOCmr:vlm YxlMYgMeedI6l:Mgmdtl m➢pol enmdu,dm 1.' W'kef, Ran:. W+Vtiv'buq 59mtrrt�er�ala t80083 ' mAYgpu;e,tlfeeeY. NeRsfnnlem➢Dmlmreamnlpddu�amPtl@!eq®nl$Mrvmp(IW,ICIWr/¢IFld1YA ueedumEmpmaptx➢r14M5!•rtgm]I:u�6iMnkGnn�P9p6.1msYagfopenvlrmsYmSaav,ekn 44$t $t. Lucie Blvd. . m %irRed Inns eep,dge YMkgh�inu�m8ud rulnv kvy[gm61Gt4NpNmP�a.ulmssp!aGfed.'1wH' B gsmdtrm wmldatlC@n. Fort Pierce, FL 34946 (vppidk®7818AI[odimsses-kevvrd.losdvill,P.L[epmlveivedlhisdvmmevl,ivmphrm,ispiv830edniPocdMe.rinee pe�sdvm6vo Ai 1ev17nssesAmdvvrl.7vmdv II4 PJ. o Truss ruse ype Y A0209296 WRMSCM15BOElL H.17A Diagonal Hip Girder 1 1 Job Reference (optional) A-1 Roof Trusses, Fort Pierce, FL 34946, design(ajatlluss.com nun: i 3x4 = 1.. a exr — LOADING(psf) SPACING- 2-M CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.63 Vart(1) -0.05 6-7 >999 360 MT20 2441190 TCDL 10.0 Lumber DOL 1.25 BC 0.59 Vert(CT) -0.11 6-7 >999 240 BCLL 0.0 Rep Stress Incr NO WB 0.42 Horz(CT) 0.01 5 n/a n/a BCDL 7.0 Code FBC2017/rP12014 Matrix -MS Weight: 43 lb FT=10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 60-0 oc pudins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc brecing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in acoordance with Stabilizer Installation quide. REACTIONS. (lb/size) 4 = 180/Mechanical 2 = 45310-10-7 (min. 0-1-8) 5 = 301/Mechanical Max Hoa 2 = 182(LC 4) Max Uplift 4 = -125(LC 4) 2 = -185(LC 4) 5 = -67(LC 9) Max Grav 4 = 180(LC 1) 2 = 453(LC 1) 5 = 301(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - Al forces 250 (lb) or less except when shown. TOPCHORD 2-11=777/214, 11-12=-727/231, 3-12=-726/221 BOT CHORD 2-16=-288/720, 116-17=2881720, 7-17=-288f720, 7-18=-288f720, 18-19=288/720, 19-20=-288/720, 6-20=-288/720 WEBS 3-6=-760/304 NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 pet bottom chord live load nonconeumentwith any other live loads. 3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1251b uplift at joint 4, 1851b uplift at joint 2 and 67lb uplift at joint 5. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 77 Ib down and 90 lb up at 1-4-9, 77 lb down and 90lb up at 1-4-9, 36 lb down and 41 lb up at 4-2-8, 361b down and 41 lb up at 4-2-8, 54 lb down and 69 lb up at 5-10-11, and 66 lb downand88 lb up at 7-0-7, and 76 lb down and 103lb up at 8-0-2 on top chord, and 12 Ib down and 40lb up at 1-4-9, 12 Ib down and 40 Ib up at 1-4-9, 16 Ib down al 4-2-8, 16 lb down at 4-2-8, 24 Ib down at 5-10-11, and 30 lb down at 7-0-7 , and 40 Ib down at 8-0-2 on bottom chard. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 , Plate Increase=1.25 Uniform Loads (plf) - Vert: 1-4=-60, 5-8=-14 Concentrated Loads (lb) Vert: 11=57(F=29, B=29) 13=14(F) 14=37(B) 15=-56(F)16=46(F=23, 8=23) 17=-9(F=-4, B=-4) 18=-19(F) 19=-28(B) 20=-36(F) reda mneamgdrminb'4l isomm mian attleaste.amw mtOtls'MnnUaLYLL®Jal'FmretlitrEpiv®slmetrtieYnvaaims&spkngl[U?d b hem, k RrllAuneflytYseu Bdesrtm�a<sidnmlPl.aj gn,emmnaas>rcmwamb>adampx e.un�ovge[.}«.(wymrghpvas.mucnurlo¢npmmc. ampumxd,avugaymxagtrbx�pamvrAmueaadummvur.cuIDt mkuyeny++e.aaymoanwaivp pntboo, T.Tombo III,P.E. drseda'a tmsbmbffi,44rtW3mgtlb0euebOrn'seksaiVlxm Dd04UuVs.abm9edrv19CLIXdbWMS9de¢i1P.J.RS Wsn:tll6IDBdaficYnedmimva:aL'9larti+mele0ffismedaesSil�hmrt4mda7i 268083 b Nit, pngmdf,mrtv lve3smmsmN4dmgmnsm!}YioxhmWdgaqum'Segt@vmiRr�}ILSFdginnimo�drmvfhpmtl}tlm1 RHVBezkmpadfc miNrstlblmshape,LessRsyp F[¢avmllmsMaCme,Mr U515t. Lucie Blvd. eer.�vaddlnomaey,rip,amsghdfl+++c,++m.lxlmsuu}[gani:rotbbeadmpw.��trusrnv6romevravAp tr��am+eroaeoAiaami. Fort Pierce, FL 34946 ///)/////��■•����\\\\\ '.- J [opdrirhl®1h76M7IvetLvsses-Av0avri.ivmdvlq EE. tlpmdvdi®vtaisdvmmem,m verybim.isprvd3uedwiihvdlhewmrtvpefmissinhvmAIrvdinsses ]mdvvryi.bchlllj.L o mss mss ype City y � WRMSC1J15B0B1L HJ7L Diagonal Hip Girder 1 1 A020929] Job Reference o tional 2x4 = 1.5x4 II 3x4 =m LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (lac) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.59 Vert(LL) 0.11 6-7 >999 360 MT20 2441190 TCDL 10.0 Lumber DOL 1.25 SC 0.53 Vert(CT) -0.10 6-7 >999 240 BCLL 0.0 ' Rep Stress Incr NO WB 0.40 Horz(CT) 0.01 5 n1a n/a BCDL 7.0 Code FBC2017/TPI2014 Mahix-MS Weight: 43 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purins. BOT CHORD Rigid ceiling directly applied or 7-6-4 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 4 = 159/Mechanical 2 = 44210-10-6 (min. 0-1-8) 5 = 274/Mechanical Max Horz 2 = 182(LC 4) Max Uplift 4 = -110(LC 4) 2 = -271(LC 4) 5 = -229(LC 5) Max Grav 4 = 159(LC 1) 2 = 442(LC 1) 5 = 274(LC 1) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOP CHORD 2-11=734/451, 11-12=-684/468, 3-12=-683/462 BOTCHORD 2-14=-523/679, 14-15=-523/679, 7-15=-523/679, 7-16=523/679, 6-16=-523/679 WEBS 3-6=-717/553 NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf,, h=15ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed ; end vertical left exposed; porch left exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 pet bottom chord live load nonconcument with any other live loads. 3)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 110 lb uplift at joint 4, 271 lb uplift at joint 2 and 229 lb uplift at joint 5. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s)77 Ile down and 90 Ito up at 1-4-9, 77 lb down and 90 Ile up at 1-4-9, 36 Ito down and 41 lb up at 4-2-8, 36 lb down and 41 lb up at 4-2-8, and 66 lb down and 881b up at 7-0-7, and 66 lb down and 88 lb up at 7-0-7 on top chord, and 51 lb down and 40 lb up at 1-4-9, 51 lb down and 40 lb up at 1-4-9. 10 lb down and 40 lb up at 4-2-8, 10 lb down and 40 lb up at 4-2-8, and 29 lb down and 71 lb up at 7-0-7, and 29 Ib down and 71 lb up at 7-0-7 on bottom chord. The design/selection of such connection devices) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 , Plate Increase=1.25 Uniform Loads (plf) Vert: 14=-60, 5-8=-14 Concentrated Loads (Ib) Vert: 11=57(F=29, B=29) 13=-74(F=-37, 13=37) 14=46(F=23, B=23) 15=-9(F=-4, B=-4)16=-56(F=28 , 8=-28) IIf1: PaAiingpl m BtlnfP.sa1v a71tleEelfA,w'r fmm1! Ca„iklmerm'Al NlIlkaAIkAZ,ragkm 11118y6FCiltIAYStrJB111[dlrfL^YjffiPa7l -- 4ft1. a uI'.IaAB{IilEsm&m1&ewt ratlov+mibtMlN,ml4eAalmk Ni 4auam lmgakpmmN•keYNhgaYGVJmvI>nmPvurane¢}isaCMl,fianvfaguelgn4��(k Mln�ptl6�ejelm,l;mMueeif-0m7.dv4A filxpmnapua.eCgm'maia�mleq "bl Anthony T. Tombo 111, P.E. ' LybMmim4:igtlhOauPe O+vi,vMOrlagehlaltyloga.Y6mvCtld9[ltY.4aWHbY;nkm1&lbq{aNtlbeldm6gnedl,lmteb`+gkfugaHleeb93md1,®f Sflhtl,ryy9tlfytl 580083 kW'elm WQk 6H#glm{adnma. Naaeea0,nehlfAdbl�ks¢llmtlmstlhktliyfrclmnkryfbn6a',LLP,.ItYdNN10mISInueMueafbimvY@!>e RNRfi¢cCrtgea!1lanel6fn[4Yna Rnpa.LntlerpOgamvllnuYmdoam.eku Lurie Blvd. MaluNmdNrNsm rs4,m YaRgllNpma, Y,Y,d lkgnukupfgm,tAll relflgkgm.uinullmu6pwtlmlNd� N�aa9kmeeml¢ad YRn. • rent P Piercen:St. e, R 34945 (epgrigAl®IIIAAJ Ioolimsses�AMvv/LivmhYlll,PJ. PepmdvdioA d0isdomvem,mvryfmm,isp�odD'ned YAhrm%e vnikvpmmissiavfivm A -I roAhvsus-AmlAmyi.iamdo0l, PJ. Job Truss russ ype ty Y A0209298 VVRMSCM156031L J7 Jack -Open 9 1 Job Refence o tional rei A-1 Roof-rmases, Fort Pierce, FL 34945, design@alwss.ce. Run: 8.210 s May 18 2018 Pnnt 8.210 s May 18 2018 M11 Intlusin". Ina Thu Feb 21 74:45:05 2019 Pagel ID:Id_OOXyyT61B_TXoljwHHzefvK-e2TuiaDtONOnYUOJFYYDOWgtAdFKNnAO8dGWyziugy 1-0-0 7-0-0 7-0-0 Dead Load Deft = 1/8 in 3x4 = LOADING(psf) SPACING- 2-0-0 CSI. DEL. in (loc) Udell L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.86 Vert(LL) 0.17 4-7 >478 360 MT20 2441190 TCDL 10.0 Lumber DOL 1.25 BC 0.64 Ved(CT) -0.20 4-7 >413 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Hom(CT) -0.01 3 n/a n1a BCDL 7.0 Code FBC20171-rP12014 Matrix -MP Weight: 24lb FT =10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- LOAD CASE(S) TOP CHORD Standard Structural wood sheathing directly applied or 2-2-0 oc pudins. BOTCHORD Rigid ceiling directly applied or 10-" oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation quide. REACTIONS. (lb/size) 3 = 178/Mechanical 2 = 34910-7-10 (min. 0-1-8) 4 = 70/Mechanical Max Horz 2 = 164(LC 12) Max Uplift 3 = -118(LC 12) 2 = -85(LC 12) Max Grav 3 = 178(LC 1) 2 = 349(1C 1) 4 = 11l(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult--160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcumenl with any other live loads. 3) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to hearing plate capable of withstanding 118lb uplift at joint 3 and 85 lb uplift at joint 2. roynm,maeveam.e.•urm=llmnrymalar9nimuacsmeuemaxt-Maltmcrrnuermm uryee�n;m�++da%mn%=mtwssamy.moeerPecedden®rttemnrilam�snvm.� eam;mn.n,amaeedml,mr gnekmvmtrb;slWPen�iludnEbgeetlaetnvwptrA°uP,.ymurmma,M Wmvrmoapnm�oe�+medpa:wmgaeagmlmnoaetalmp;odse$ew.�l;awmmmomn mmmt u,hpmumw,xpgmmn,van61 Anthony T. P.E. rmGgdmPtdugmmNGqlbewed Orse�edeiaehld169An9�*.adma0tld6C0eCmllehd MY9M��m10.1.A6FlNBdNldmfied enddime WwuA4'BTf�9sem92ndYus3ildNbn4v}dryE 8Tembo 0083771, J80083 ybxglugmclr.4,MN¢1s Nemsdlne4dM�msefydlaaBdRb•g4eezAYlfrVYv®n�pNNelli Vltl9fAeaedueazl6pNplae llnktve;HeeyemJYEuimlhffitlLR;btlpa.l,rt;N;yaOraemlro-utlIDGMm.e'm mikw' LUde Blvd.494 e}Mul4ndlpea�eredepimmrryeopre mmut Mlnuk:ryre(w.71;rGtkrapqpv;pu,e,InuSrybtgvedmtlRAry N�ffi4bmmm13atltRn. F9rL Pi¢R2, FL 34946 Fed Rem (v b®POIf411ov1lnssn-Ivavv 7.rvmpelryVt le mio4ivv otaislommen,ivov k� a Rhi6nvEmAEvnke mdlrte emnuwhoml-I Bed7nsusAOMov i.reotoN,Pt. Plnr P P 9 m,' P P r o mss cuss ype ry y WRMSCM15g0a1L J7L Jack -Open 5 1 A0209299 Job Reference (optional) nun: 0.4 4x4 = 3x4 = Inu LOADING(psf) SPACING- 2-0-0 CSI. t DEFL. in (lac) I/clef] L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.52 Vert(LL) 0.18 6-9 >460 360 MT20 2441190 TCDL 10.0 Lumber DOL 1.25 BC 0.54 Vert(CT) 0.15 6-9 >542 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.19 Horz(CT) -0.00 6 n/a n/a BCDL 7.0 Code FBC2017/TPI2014 Matrix -MP Weight: 30 lb FT = 10 LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc puriins. BOTCHORD Rigid ceiling directly applied or 6-1-2 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (Ib/size) 4 = 91/Mechanical 2 = 349/0-7-10 (min. 0-1-8) 6 = 159/1'Jechanical Max Hom 2 = 164(LC 12) Max Uplift 4 = -69(LC 12) 2 = -134(LC 9) 6 = -125(LC 9) Max Gmv 4 = 91(LC 1) 2 = 349(LC 1) 6 = 165(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOPCHORD 2-3=-323/338 BOTCHORD 2-6=-582/283 WEBS 3-6=-307/633 NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; porch left exposed;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 pat bottom chord live load nonconcurrent with any other live loads. 3)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 69 lb uplift at joint 4, 134 lb uplift at joint 2 and 125 lb uplift at joint 6. LOAD CASE(S) Standard [¢61Pom4mgEjrMnm'41tl�fi10SSarSIllfPl �i3tmWrrJp9J6[a1pN(6'rl'JIa&F.klJifl•le[IvtlyhoPpraMyul ayK nOSlmrMgke.gllIX^;d6YSa11 L—A 41FfA,arA�nkhrtne @ilmCna 90Nmk1W,mj Mds1®,MlkRsilik,WhrmN04YNLIs.im�Bopf�mep¢.SpWryfcvd mssOnvlMryrnarmmpmaamrd rma;se�gn4m:Ltntrtrty®ahajclmr4mmmiW®}.MeAi.Ah¢rsnaPm�6arim]om.uYb'Op A thmy T. T=b0 III, P.E. ' dm dW Nnkminl8f ismmpaE'40&Mmm O¢m'vda3rtya¢h WWpuiµ+,¢trmaadm X D,KmlmkdlaYapnkdmt ikq Id,, n9dmktlmamrmciHykd'gmrnt4mBdnmtnviY£k traspalq d ..80083 trW, lnprdkaw. Nmm...ftwWtrrymvmpiba dm kanfi eeso, xavma;��lmomp mmvammuevl6lmNgLLU m:ihhmlLat(mmme1m606am4ypdpr.tmspnpkpadrmvtlammu,dm 44616L Wtle Blvd. a¢mu Kind h.k4rolrpWrp d M JllelpmaHrel Mk kutqen¢Ihimb#gkGm.nimsSrs3.EyneeaalM64V tl 9tla°.tu. ldd bon. wn Pierce, R. 34946 hpp+igti®P016AIIW lmxus-AmdoapLlcviNll,1.L&pmdvmao:Inisdommm,murfwnilprelilnedwiM:mke nnnmpermissioohom A -I teoibs. -46DryLTD. 10L Job Truss cussType ti Y A0209300 WRMSCM156OBlL JTT Jack-0pen .y 6 =Refere�� l A, e<wr susses, ron rierw, re ,waam, mesignAn}aswss.wm U4= I.bx4 II Ia Dead Load Deft. =118 in LOADING(psf) SPACING- 2-M CSI. DEFL. in (loc) I/deb L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.34 Vert(LL) 0.22 6 >384 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.34 Vert(CT) -0.23 6 >359 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.07 5 n/a n/a BCDL 7.0 Code FBC2017/TPI2014 Matrix -MR Weight: 27 lb FT=10% LUMBER - TOP CHORD 2x4 SP M 30 SOT CHORD 2x4 SP 2400F 2.0E BRACING- TOPCHORO Structural wood sheathing directly applied or 6-0-0 oc pudins. BOT CHORD Rigid ceiling directly applied or 6-" oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 4 = 166/Mechaniml 2 = 360/0-7-10 (min. 0-1-8) 5 = 871Mechanical Max Horz 2 = 164(LC 12) Max Uplift 4 =-105(LC 12) 2 = -78(LC 12) 5 = -7(LC 12) Max Grav 4 = 166(LC 1) 2 = 360(LC 1) 5 = 118(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - AI I forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; VuI1=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 105lb uplift at joint 4, 78 lb uplift at joint 2 and 7lb uplift at joint 5. LOAD CASE(S) Standard pmdp.Pourm, "fit - Im'IJr�i1�6(LLLLaj➢ltlaMi6(%U10nU41Wl-i!''In'lln"S,aorarme tatlf6upNm"mmwltln r41 Opmrvq(@L;dm{CgtL-tie, itlLaveHMMnuOtlarePerRe OPln@iW.aY mmmx�enst omm Nbmiieam ma as➢rss¢es�pmparpa yne: ma<mwavrim�nmsewpaaampnn�maw n'�aevrmmingsamsgrmutymlamIDoaapadmi a,brq,wmao,vzgmmmsnam Anthony T. N, P.E. mo,tl64lrc mwmYmp 6mN�3fn6hMwm0ml�e4EtlePvmkMM4nC rmmmimmCmCgmYmkY"iMemVH➢4TNdW@4mdmPoHmd4rmxeYsil�E'4mM.hA'ISmmEtuH6IDNmrt�+Y'%1 8 30083 8Lude mr.+%pMS,ndfgv. Wmmrmemmogmn�msgpAmv¢mmumamnnssmnnnmv;�pmmasrtngvummmemmlmmpdawlmssmumativusmmasumuesompe.imseny+ayaemrrmmmau,mm 41518t. tacle Blvd. Ra4v16vtllrem4mopdgnre�mghBpmmdret iktm,m.ry Fgpa�h LM1tmrmMairvAw,minufrnafspwdmimldry NwWlxibm mWAm1PH. Fmrt Pwme, FL 34M6 �fvpyriph101�76M11vvnrmns�AmlvryLivmhvlll,7.E tepndurDvs vitlfzdummevl,ivvvylmm,ispmhanedxuhemtdermhe pmmissievhvm A -I Boofinsses�Amhwrl.ivnhv041'.E Job I russ I loss I ype Fly A0209301 WRMBCM15C0B1L TG6 Common 4 1 Job Reference (optional) A-1 Roof Trusses. Fart Pierce, FL 34946, design®alauw.com Run: 4x8 = 6.00 12 1.5x4 It 3x8 = 1.5x4 II 3.8 = 1-2-0 9b0 LOADING(psf) SPACING- 2-M CS]. DEFL. in (loc) Well L/d TCLL 20.0 Plate Grip DOL 1.25 TC 0.24 Vert(LL) 0.09 9-10 >915 360 TCDL 10.0 Lumber DOL 1.25 BC 0.38 Vert(CT) 0.07. 9-10 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.09 Horz(CT) 0.00 9 n/a n/a BCDL 7.0 Code FEC2017frPI2014 Mabix-MS LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No-3 BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc pudins, except end verticals. BOTCHORD Rigid ceiling directly applied or 10-0-Ooc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 10 = 41510-3-8 (min. 0-1-8) 9 = 415/0-3-8 (min. 0-1-8) Max Hom 10 = 147(LC 11) Max Uplift 10 = -194(LC 8) 9 = -129(LC 13) Max Grav 10 = 415(LC 1) 9 = 415(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 3-4=-95/251, 4-5=-95/251 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult--160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. II; Exp 8; Encl., GCpi=0.18; MWFRS (envelope) and C-C Extedor(2) zone; cantilever left and right exposed ; end vertical left and right exposed; porch left exposed;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) •This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 194 lb uplift at joint 10 and 129 It, uplift at joint 9. LOAD CASE(S) Standard PLATES GRIP MT20 244/190 Weight: 69 lb FT = 10% FOOq.11mm,grlrm@vm'4110pfiLffifl(IIIIff16ECilt m➢itl�'llC6n{Idl(NIRI1pE11aJarlve ielr69•IvmJmdrttlmnmMlmfM46vg114G;d6LLer1.I¢bgilMem,9MVn e,. LWn�6zvb 0MnLN1. GlMuma!@'.samMmibbWYN4 b.uwwWW¢m0.r.lMmRlhYvYsmwn9Ro,mn�m•v�@em WmmwMbinxmaMtbtleraacsW, mnA9�mmmoW.dvmLmfnWrsane.MSm:nayumaq Anthony T. Tombo 111, P.E. dmdluimvtrgkYqubrtevd'a,EbPim.bOmitdx@tlyM1lmtalUe�s,iNMnANH.bLWNMW,d,d mL mgpMib W d,Wmm41mtt1W11�{ M1y,.•nu'0t•W"Uks le.1am d 3Boo83 ml�vb�ryreAtlaniN6b6bLmWYrs.l,mhsgf¢eralro¢ertn4 ¢�pYgingmdrmw.i0mm,lstbWdbl�Mm�dpl,Iw.m16htl9glq:,mYl4pfevem 24)rYWNNRId WImwartimi. I 44515L Luc!! Blvd. rfvMu W911.rdmgd9vMogllmryMVMtlnI mPrupuxftleatltOftilBYglc4m,vmnsroaitfm�mrp09y WgtivMkemmlhtl•mL .a � Fort vieRE. R 34946 4 b®7{I{Ml leelimsses-Am4o Clteitm,rk [r ndtNotole'ndo®e PPiI q P vl,uvgtoipirproY3drEitlhombemneope�nieotiom A -I kvlimur-Avrtoorl.lomb tt, IJ. Job Truss russType Y A02M302 WRMSCM1560BIL TOGA Common 1 1 A Job Reterence o 6onal A-1 Roof Trusses, FortPierce, FL 34946, design®al Wss.dom Run:8.210s May 162018 FrM 8210 s Mayy182018 Mi iek Industries.Ina Thu Feb2114:45:072019 Pagel ID:ld OOXyyT61Bi TXoljwHHzeNK-aRbe7bmTPdd6lsenRgaOJpbLmOzoGsTsS6Mbmiugw 1-24 4fi-0 7-9-12 1 r, -2J1 a12 � 3.3-12 —' 1-24 48 = 6.00 12 1.5x4 II 3x8 = 1.5x4 II 3x8 = 1.2-4 9A0 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Well Lid PLATES GRIP TCLL . 20.0 Plate Grip DOL 1.25 TC 0.19 Vert(LL) 0.09 7-8 >900 360 MT20 2441190 TCDL 10.0 Lumber DOL 1.25 BC 0.37 Vert(CT) 0.07 7-8 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.09 Horz(CT) -0.00 7 n/a n/a BCDL 7.0 Code FBC2017fFP12014 Matrix -MS Weight: 65 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 6-M oc pudins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation culde. REACTIONS. (lb/size) 8 = 32210-3-8 (min. 0-1-8) 7 = 322/0-3-8 (min. 0-1-8) Max Horz 8 = 135(LC 11) Max Uplift 8 = -98(LC 9) 7 = -155(LC 9) Max Gray 8 = 322(LC 1) 7 = 322(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1291283, 3-4=-129/283 WEBS 2-8=-208/305, 4-7=208/304 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=151t; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Extedor(2) zone; cantilever left and right exposed ; end vertical left and right exposed; porch dght exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 98 lb uplift at joint 8 and 155 lb uplift at joint 7. LOAD CASE(S) Standard e..+lrwvm,rt7v,e.d•uaelnmis(w[rAcmmlmuer,¢mcacmmarfsnn7w¢sar[mmrm raer6vm=�Uvsmvs+vmvmla,ov�u,.4AR!m'm+dmrAs�,u;rtmnnn:nma+m. uasse�a�mamo.wy Wieisn:re{mSSY9MmelbPeC41mM,WLL Iv+4nekprhpmePtyemO(a@x�6Wwg14p,mevmovre,+9MpEwo+mq'�upngautOrtibtrlvsytlAe,pet,nviymNnNlIDa¢.gctlt6lspnnalnnmmga+A:l,n.am1� An(JrpnY T. ill, P.E. NwENtmrb4lwgolkhmp>�Ig4h0.w.h0+m's�aJ4Evm+k'09HWR..hrto2fi+mf.tlrCmMW5K1.'ft RL AOY+�GdbIDBu-0w®Y+i,64G+rsW6+l1.d�N9tmrmOsmdtas3 A3bCnyw 7•d 80083 390083 maxgvvgmmme+a mvesmmt.m>oe+mmrm�mgnuunFmkmyu..rxnse�mNnmmn,reiwihmlmSWa+m�vms�Ipoeu RLiafasvmvra�nAuvdewerLuenge.urssenqugwmluu e. 5m.,vRs 44515L Lucie Blvd. +xrdup¢wh+umm+m49vmvmahm M+smNVA r mssdvprva�i.rbtuevagtuga,elmsllsumpmevrrmq me4nasfevwmadmdmml. Fort Pierw, R 34946 /////(///.�■•���\\\\\\ (vhripM�IDIAA1 Hodinsses Amhvvyl.T4mLv HI,Pi Hepmdv0ivv ohlisdo®era,ivmyimgispwtrl'nedwi%sNM+wnaevpemissiv+tramAIHedinsms AmbulT.h.4.10,Pt Job I FUSS I ype ty R A0209303 WRMSCM1550BIL T06SGE Common 56uctulal Gable 1Ply 1 JOb Reference (ootlonal) rem nussa.. rmn tierce, r� .wwm, wesign(3w alwss. Wm bun: a.zlu m Ma&lg Pnmt 6.21U a May 18 2018 Ml l ex lndustnes, InC. ThU Fb 21 14A5:07 2019 Pagel --0-0 24 4ID: dOa1Bi_TXol)wHHzefvK-aRbe7bmTPdd6lsenRgaOJpbKSzOloGtTsS6Mbaiugw 12 YMs Mil-01-0-0 1-23 4x8 = 3x8 = 3x8 = 1-24 18 7-9.12 8 H 6-7-8 0-1-12 -08 Plate Offsets (X,Y1— 14:0-2-0,04)-41. 15:0-0-0,0-MI 16:0-0-0 0-0-01 It 8:0-1-15 0-0-121 (18:0-1-15 0-0-121 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Lde0 Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.24 Vert(L-) 0.09 9-10 >915 360 MT20 244/190 TCDL 10.0 Lumber DOL 1.25 BC 0.38 Vert(CT) 0.07 9-10 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.09 Horz(CT) 0.00 9 n/a n/a BCDL 7.0 Code FBC2017/rP12014 Matrix -MS Weight: 84 lb FT=10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purins, except end verticals. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, In accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 10 = 415/0-3-8 (min.0-1-8) 9 = 415/0J-8 (min. 0-1-8) Max Horz 10 = 147(LC 11) Max Uplift 10 = -194(LC 8) 9 = -129(LC 13) Max Grav 10 = 415(LC 1) 9 = 415(LC 1) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOPCHORD 3-4=-95/251, 4-5=-95/251 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; canfilever left and right exposed ; end vertical left and right exposed; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per 4) All plates are 1.5x4 MT20 unless otherwise indicated. 5) Gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) • This truss has been designed for a live load of 20.Opsf on the bottom chord In all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 194 lb uplift at joint 10 and 129 lb uplift at joint 9. LOAD CASE(S) Standard Every'FwQvrryhm¢v&-L1UC'rn5f6[2lt0j araLLNpi1(0®'AN6rBIN11Re-jIOCP,pirlRha.leEIbYPIn,aumml M,MRM,1msBn4mevRle^+,tlh4fipl. LSA4111Arm,LviMu,rtx Cdas,Oawu Ds•JnLIDf. } r11,1mcNlbtflIDbeul6,trIDDm Nna AulmiCn•NmxPa.yvdry LpvY 6W ugtCCnpunnbmnyenapb P2n,btlegvmhBnymuimrfrmele@tltlsvjeNulgahlnMIldehuln0.L 0ra!{IpnneNnhmpatAmyRTJ'S( Anthony T. Tombo Ill, P.E. cimtlLJtmtbgNl6FrsbnyauVertlb C.u,.hC.uis2mcJ,gSrtrM�rreh�.vamnatld YC4KallehdlaggM,tl0.La,p;mJitr Wdmratlm E&rmch65gbQgsmq�.emllEm,dhngJ64Hnye,auiL T80083 trDVVyCagnd<mes. NubmmptlII4e4trPbnsmlPtlJvndm, 4JBg0WasY:}�vm,701JIJLptlhmdWlmNveafYlmtlP=vm llWMmcfa,Mrndlax, ml0nnp41ru E,YPe.lmslnp4pevllm;(nhun,Wm 4451 St. WCIe 1310. rNmul6,dheNmneyr3whnc9hNPmnanlRtmlm,N;gl9ummeatreaxaln ,mm�hma Nlh�namrbas NpltivahrnnenlpaelRlpl Fort Pierte, P. 34946 (epmiAm0761{411ediuues-AmlogLlomEoeLPE 4pNdo0ioe of8idnxmeeLhNflorcis Prol7uedwaedae n0leepeimissiwhomA-I IoolLesus-AvtonrLlomlo N,Pi Job Truss nlssType A0203306 WRMSCM1560BlL VM08 Valley 1 1 4 Job Reference o tional ,.,-.moo, ,mm.,+.ua,I 4 0 3x4 = 2 3x4 = 3 4 2x4 G 1.5x4 II LOADING(psf) SPACING- 2-M CSI. DEFL. in (loc) 1/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.54 Vert(LL) n/a - We 999 MT20 2441190 TCDL 10.0 Lumber DOL 1.25 BC 0.22 Vert(CT) n/a - n/a 999 BCLL 0.0 " Rep Stress Incr YES WB 0.00 HOrz(CT) -0.00 4 n/a We BCDL 7.0 Code FBC2017trP12014 Matrix-R Weight: 20 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc pudins, except end verticals. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation quide. REACTIONS. (lb/size) 1 = 19315-11-8 (min. 0-1-8) 4 = 193/5-11-8 (min. 0-1-8) Max Harz 1 = 70(LC 12) Max Uplift 1 = -46(LC 12) 4 = -58(LC 9) Max Grav 1 = 193(LC 1) 4 = 193(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psF, h=15ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurtent with any other live loads. 6)'-This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 46 lb uplift at joint 1 and 58 lb uplift at joint 4. LOAD CASE(S) Standard Bm¢y,Ym6nuyVlm`ab'LI tt91aff6!1Wa}e@alllab A(GM9Rp6 W9djiNa1llW61a!@'ATma htlltrvpicmnsalninswfkHrts�¢kn4lnrlb�Al.tmA6lF12m&�Ildmn. Pim�qualgo4r.0.uq W.94' hm A`iaxtltrAWa+k rtd hrinvkcgh}t Ge.Ns-hFgm}bsrdmWla�. aCmen&IDmdkad�wmim�vilnvAY!m6a�dtrWbLms m®i9N.WMt IYksPnms-atmtaGSn,¢e'v! MrhonY T.80083 l6, P.E. elmrddi lm ,e§, man(b&,6Ge1h49ba9vF iNeM�ddBsiNml4�iwdklmt hd4 ouW n5fCmdlrq�LmmCosA!%d •.Lde ' Wm'Al. W. mC�bWN'Grmtldua,IP�adlK h4WlhYpmdfaffip,{LmbuiNnClAtlbFsvutlRl+`++ribr Yaua�$l9k.i' MiflvdRle�Nead4 WrtlP���MIConm,e9ml+�atkenl➢et�wEgm,Lm OwDal�dSmstlxEehc.aAn 64515rm, Blvd.494 haft All, ro+:ukud4r(ul�mymridrdBhdi�ad,d. bimslmP4�^'nCnmYYwrnip,almsNdm b3asdml.Vay l9ujtl0almmv,nlhAvAt FL Fat Plerce, ft 34946 � (vPP4baY&16A-i ¢vdrmsnAm6vvrtivmhv 0,Pi kpodedmv deis Aemaltl,uurrfarwupo§3Led+0lnl Bxadtmpnmissim5ema•ItvdhvssesAWdvg7.7ac6o06Pi Job Truss I was I ype ty y e A0209305 WRMSCM15IS0BIL VM10 Valley 1 1 Job Reference o tional A-1 Roof Trusses, Fort Pierce, FL 34946, design@albuss.wm Run: 8.2.0 s Ma 18 2018 Print: 8.210 s May 18 2018 MiTex Industries, Ina Thu Feb 21 14:45:08 2019 Page 1 ID:Id_I�OXyyT61Bi_TXoljwH HzefvK-3d9OLxn5AxlzeODz?05Frl8U1 NnEXjao46sw7Hziugv 8-0-0 8-0-0 2x4 % 5 1.5x4 11 1.5x4 11 4 1.5x4 II LOADING(psf) SPACING- 2-" CSI. DEFL, in (loc) I/deft Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.23 Vert(LL) nla - nla 999 TCDL 10.0 Lumber DOL 1.25 BC 0.11 Vert(CT) We - nla 999 BCLL 0.0 ' Rep Stress Incr YES WB 0.12 Horz(CT) 0.00 We We BCDL 7.0 Code FBC2017/IP12014 Matrix-P LUMBER - TOP CHORD 2x4 SP No.2 SOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0.0 oc pudins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-" oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1 = 89f7-11-8 (min. 0-1-8) 4 = 111/7-11-8 (min. 0-1-8) 5 = 33517-11-8 (min.0-1-8) Max Hom 1 = 147(LC 12) Max Uplift 4 = -51(LC 12) 5 = -155(LC 12) Max Grav 1 = 89(LC 1) 4 = 111(LC 1) 5 = 335(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 1-2=275/117 WEBS 2-5=-2721418 NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-secend gust) Vasd=124mph; TCDL=4.2psF BCDL=4.2psf; h=15ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and G-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces 8 MWFRS for reactions. shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psi bottom chord live load noncencument with any other live loads. 4)' This truss has been designed for a live load of 20.Opsf on the bottom chard in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 51 lb uplift at joint 4 and 155 lb uplift at joint 5. LOAD CASE(S) Standard PLATES GRIP MT20 2441190 Weight: 31 lb FT=10% pFerr®.m.Pryr.a.m�laaalws¢[Fm¢Ywrunmrkmmmnrmtaa�+¢uvlmsu¢re,.rr.awFa.'n.F�r,m,nano.,meso-..vPFarmbawt.lwbmrirm,m,unmrru mma'a.,wem.al�m.M K'd®emr6mmAbadmmlplahr6l Lrlm�mrp W@e,4r,.Y�hrn®Am,a.wmrsm+.anmdmM,nrnw�ae!bm[. camvN UR,q�.r®m1nW. r. rut bmMemAm.�or.io.mwn Anthony T. Tambo lll, P.E. r,nd6mm�mgxrgmm� ldm Pav,bmm5.4am19.•m4"`.paq�.Ym¢f4db Kb Krmwh"aNrtu Rq„ddmtiprgmtlm dmlm'bakibrgnvµblkmrkvgadl bm nx."d 4Tomb 10083 ' mmu.by.rtm�.ua�mrem>wrbp.emrpa�.,dbutsgf.�afaray.m�pbad4wrWn,d..�emymar�m tmru m.•.,etmrrrmamu,umr•e,wempar+mrue:mmro..,�u 44515L Wtle Blvd. dlmvarwi4ddtl4rgnbaTghdphomma hb,uhtlplyenbr]immiagk�.•1ma1ry,a4podnWy tngtl Vmonnld�at0.1. fmt Pi&cE,R 34946 ( t01B16d-1 ladtmvstv0v I.tvmSv PL le rtEadsvd0irdvmmd,'m fvem,8 vhaud•mvr0le nmev °Pf^PB W 14 p mf P pvrssbvaem411vdlnsmMevgl.7mm K,rE Job Truss cussType y A0209306 WRMSCM156081L VM12 Valley 1 1 4* Job Reference o clonal A-1 Roof Tmsses, Fort Pierce, FL 34946, design@al Vussmrn 6 Run: 8.2f0 s May 18 2018 Print 8.210 s May 18 2018 MiTek Industries, In¢ Thu Feb 21 14:45:09 2019 Page i ID:ld OOXyyT61Bi_TXoljwHHzefvK-XgIPYHnjxEtgG9o9Y5cUOEgeOn6XG9a1JmbTfkziuqu 10-0-0 10-M 2x4 - 5 4 1.5x4 II 1.5x4 II LOADING(psf) SPACING- 2-M CSI. DEFL. in (loc) I/deft L/d TCLL 20.0 Plate Grip DOL 1.25 TC 0.31 Vert(LL) n1a - n/a 999 TCDL 10.0 Lumber DOL .1.25 BC 0.17 Vert(CT) nla - We 999 BCLL 0.0 Rep Stress Incr YES WB 0.14 Horz(CT) 0.00 4 n/a We BCDL 7.0 Code FBC2017/TP12014 Matrix-S LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins, except end verticals. BOTCHORD Rigid ceiling directly applied or 10-" oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation aulde. REACTIONS. (lb/size) 1 = 12419-11-8 (min. 0-1-8) 4 = 145/9-11-8 (min. 0-1-8) 5 = 414/9-11-8 (min. 0-1-8) Max Horz 1 = 188(LC 12) Max Uplift 4 = -67(LC 12) 5 = -190(LC 12) Max Gmv 1 = 124(LC 1) 4 = 145(LC 1) 5 = 414(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 1-2=314/128 WEBS 2-5=-330/474 NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. It; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C.Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions. shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonc incurrent with any other live loads. 4) ` This truss has been designed fora live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 67 lb uplift at joint 4 and 190 lb uplift at joint 5. LOAD CASE(S) Standard PLATES GRIP MT20 2441190 Weight: 40 lb FT = 10% Poq.F vuanp4lnMtre'3i65i4M1S8i�a-'rL tLLla'6t6If.�I1TH'9S1W(WS%{arOfV06Yat'ma hrtf ism'x•rdMuvxti�LruW4ko*411&1tlN44ryLfekR1F44m+rSmn,nt brv�3 x01�,W, wdewtmtl+mrorhlnex,smagmeMLwgmaSlamalPmni§e3xi&a6 .a1Sime ,mwmsa a ,asaya<a). pdm,yaim:a,® xx.m4mci,,kdgincim� Anthony tF[, PE. [LLx,h1c,me,vOg�u,yYa,ree�p.,dy,�pcdrcutrlantsriY%m� mdYRtKW&Wbu1AtlX6'MMditndquad0TmbiegatlMk®W.ftnqm2fd 480083 ' MWY9RY}aolfamm Nmbm,neLR3tlmF,�+dp6'zxabl"MqO+ixdidMtl,v'n9�InhddbTMWv,eCeuoffal�dr�ffiftlm,6iT,+de/,dMm06Nu &,V�.Lre EnOrOpBtl:ra,Y¢AOvu.�, 4451 Sr. lode Blvd. .a,wldmN, �tlgdgxbnaq%dplmMdd ibim eNp6}'u�,bplYldSykil�v..Le,Laxud.iwe�y L1geua16rmnnadadaml- Fat Pletce, R 34946 tdPR'9b9P01dkl evdlrmus-Aeiov7LivmEeq Pi kp dvdwtlitislemmem,'mmgiwm,6no�drd �i@vmeeabtupna6sintrcm6trve14ayses-hWgLT abll4F.E Job I nlss I russ ype Qty Ply e A020930] WRMSCM15o081L VU14 Valley 1 1 Job Reference (optional) A-1 Roof Trusses, Fart Pierce, FL 34946, design@albruss.com 3x4 i Run: 8.210 s Ma 18 2018 Pnnt 8.210 s May 182018 MTek Industries, Inc. Thu Feb 21 14:45:09 2019 Pagel 12-0-0 ID:Id_O(�XyyT61Bi_TXoljwHHzefvK-XojPYHnjxEtgG9o9Y5cUOEgoQn4WG9EIJmbTfkziuqu 12-0-0 1.5x4 II 1.5x4 II 3 1.5x4 II LOADING(psf) SPACING- 2-" CSI. DEFL. in (too) Well L/d TCLL 20.0 Plate Grip DOL 1.25 TC 0.44 Vert(LL) n/a - n/a 999 TCDL 10.0 Lumber DOL 1.25 BC 0.30 Vert(CT) n/a - n/a 999 BCLL 0.0 ' Rep Stress Incr YES WB 0.16 Hom(CT) 0.00 4 n/a n/a BCDL 7.0 Code FBC2017/TP12014 MatdxS LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc puffins, except end verticals. BOTCHORD Rigid ceiling directly applied or 10-M oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1 = 153/11-11-8 (min. 0-1-8) 4 = 174111-11-8 (min. 0-1-8) 5 = 503/11-11-8 (min. 0-1-8) Max Hom 1 = 229(LC 12) Max Uplift 4 = -81(LC 12) 5 = -232(LC 12) Max Gray 1 = 153(LC 1) 4 = 230(LC 19) 5 = 503(LC 1) FORCES. (Ib) Max. CompdMax. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=363/149 WEBS 2-5=-402/545 NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=4.2psf; h=15ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Extedor(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber .DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load noncencument with any other live loads. 4)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL= 7.Opsf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 81 lb uplift at joint and 232 Ib uplift at joint 5. LOAD CASE(S) Standard PLATES GRIP MT20 244/190 Weight: 48 lb FT=10% Y..a.r+amvyMrnmQ-Nirdnp{Sa(y9talWlall101atNYmanaPOapPdjl�Maa"irb+1ad16yFnnntlndmn�etivi,mdmpQ.y(eGd4k44Li+46li. WMm.flRlfia. ffiac3niv(fld+b100.+? wta�.n,lamQod.mtrmlcanlnw uvu,vo.Rye.,p,,y,r ytvp+,yQ,m+yrd„„®,a.m�.abpe+u:avy�„s+oderQQasPaQ�nlmsb�d.Qleomr.tl.PltQmgomamltlym.,+ Anthony T. Tombo ill, P.E. nrnddvim�b¢rpdynQrtva,t3ldQCm.QOm1�b1Cm.QQYq M.'1.vQmMaaQm,hA(.r6kl MJelub.IRH. ru grynitlQl9dgbYmdQ4mmaagbOqtrq.eo�ed6aq QHdQrtam46}d 600e3 b Wsq Mgmtlfufa�u+wwreQlWeYp,mtlpm'mabidigt�vm6'n4vraapOgrLLmlhn+Ixa.,KenrlbPadpm filldenQngaillar,tlamdQu,uEym,4m E,pfq.,vdimru,�xr,.Ln 4451 Sr. Lucie Blvd. .mwm+dpvfmacmrw:vagrymwnum,nd ➢,Lovlmvepvunual It e..tmcsnno4d.an�da ugmuaemnnrd.!'.mi � Fart Plerce,A. 34946 (vp1nIMQJ 1p10411vdtmur/o6mpl.Ioe5o01, PE 4pvdvNavd Nrdemard,uvryMahpo6b0v1a10od15emm�pddissiavham411edinvu+kOvoyl.lv¢da0,ri JANUARY 17, 2017 I TYPICAL HIP / KING JACK CONNECTION I STDTL01 9 CORNERSET GENERAL SPECIFICATIONS MAX LOAD: 55 psf Roof Load, 175 mph, ASCE 7-10, Exp. B, C up to 60' Mean Roof Height and -Exposure D up to 30' Mean -Roof -Height. - A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 Attach End Jack's w/ (4) 16d Toe Nails @ TC A (3) 16d Toe Nails @ BC 0 Attach King Jack w/ (3) 16d Toe ,Nails @ TC & 24" Strap w/ (6) 10d x 1.5" ea. end @ BC 3ch Corner Jack's (2) 16d Toe Nails ), TC & BC (Typ) Attach Corner Jack's w/ (2) 16d Toe Nails @ TC & BC (Typ) Aiftm T. 'IV III, P.E. SsaeBY 445LSt.Iiicle Blvd, Fbt P(,eicz fL�349A6z FEBRUARY 17, 2017 I ALTERNATE GABLE END BRACING DETAIL I STDTL03 AA ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 ALTERNATE DIAGONAL BRACING TO THE BOTTOM CHORD 1'-3' MAX. DIAL. BRACE AT 1/3 POINTS IF NEEDED IT IS THE RESPONSIBILITY OF THE BLOG. DESIGNER OR THE PROJECT ENGINEER/ARCHITECT TO DESIGN THE CEILING DIAPHRAGM AND ITS ATTACHMENT TO THE TRUSSES TO RESIST ALL OUT OF PLANE LOADS THAT MAY RESULT FROM THE BRACING OF THE GABLE ENDS. HORIZONTAL BRACE (SEE SECTION A -A) TRUSSSES 24' D.C. 2XG DIAGONAL BRACE SPACED 48' O.C. ATTACHED TO VERTICAL WITH (4) - 16d NAILS, AND ATTACHED TO BLOCKING WITH (5) - IOd COMMONS. NAIL DIAGONAL BRACE TO PURLIN. WITH TWO. 16d NAILS. 2X4 PURLIN FASTENED TO FOUR TRUSSES WITH (2) - 16d NAILS EACH. FASTEN PURLIN TO BLOCKING W/ (2) - 16d NAILS (MIN.). PROVIDE 2X4 BLOCKING BETWEEN THE TRUSSES SUPPORTING THE \ BRACE AND THE TWO TRUSSES ON \EITHER SIDE AS NOTED. TOENAIL \ BLOCKING TO TRUSSES WITH (2) - \ 10d NAILS AT EACH END. ATTACH DIAGONAL BRACE TO BLOCKING WITH V(5) - IOd COMMON WIRE NAILS. ENO WALL CEILING SHEATHING BRACING REQUIREMENTS FOR STRUCTURAL GABLE TRUSSES STRUCTURAL GABLE TRUSSES MAY BE BRACED AS NOTED: METHOD 1: ATTACH A MATCHING GABLE TRUSS TO THE INSIDE FACE OF THE STRUCTURAL GABLE AND FASTEN PER THE FOLLOWING NAIL SCHEDULE. METHOD 2: ATTACH 2X_ SCABS TO THE FACE OF EACH VERTICAL MEMBER ON THE STRUCTURAL GABLE PER THE FOLLOWING NAILING SCHEDULE. SCABS ARE TO BE OF THE SAME SCAB ALONG SIZE, GRADE, AND SPECIES AS THE TRUSS VERTICALS. -VERTICAL NAILING SCHEDULE: - FOR WINO SPEEDS 120 MPH (ASCE 7-98, 02, 05), 150 MPH (ASCE 7-10) OR LESS, NAIL ALL MEMBERS WITH ONE ROW OF I0d'(131' X 3') NAILS SPACED 6' O.C. - FOR WINO SPEEDS GREATER 120 MPH (ASCE 7-9B, 02, 05), 150 MPH (ASCE 7-10) NAIL ALL MEMBERS WITH TWO ROWS OF 10d (131'X3') NAILS SPACED 6' D.C. (2X4 STUDS MINIMUM). MAXIMUM STUD LENGTHS ARE LISTED ON PAGE 1. ALI BRACING METHODS SHOWN ON PAGE 1 ARE VALID AND ARE TO BE FASTENED TO THE SCABS OR VERTICAL STUDS OF THE STANDARD GABLE TRUSS ON THE INTERIOR SIDE OF THE STRUCTURE. NOTE: THIS DETAIL IS TO BE USED ONLY FOR STRUCTURAL GABLES WITH INLAYED STUDS. TRUSSES WITHOUT INLAYED \S ARE NOT ADDRESSED HERE. / STANDARD GABLE / TRUSS UKAL TRUSS etinm AN ADEQUATE DIAPHRAGM OR OTHER METHOD OF BRACING MUST BE PRESENT TO PROVI13E FULL LATERAL SUPPORT OF THE BOTTOM CHORD TO RESIST ALL OUT OF PLANE LOADS. THE BRACING SHOWN IN THIS DETAIL IS FOR VERTICAL/STUDS ONLY. STANDARD PIGGYBACK TRUSS JULY 17, 2017 ,,, KIK,� I, Ikl M=A„ STDTLO44 THIS DETAIL IS APPLICABLE FOR THE FOLLOWING WIND CONDITIONS: ASCE 7-98, ASCE 7-02, ASCE 7-05, ASCE 7-10 WIND STANDARDS UNDER ALL ENCLOSURE AND EXPOSURE CONDITIONS AS LONG AS NO UPLIFT EXCEEDS 377 LBS. REFER TO ACTUAL PIGGYBACK TRUSS DESIGN DRAWING FOR UPLIFTS. NOTE: THIS DETAIL IS VALID FOR ONE PLY TRUSSES SPACED 24' O.C. OR LESS. A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 PIGGYBACK TRUSS REFER TO ACTUAL TRUSS DESIGN DRAWING FOR ADDITIONAL PIGGYBACK TRUSS INFORMATION. SPACE PURLINS ACCORDING TO THE MAXIMUM SPACING ON THE TOP CHORD OF THE BASE TRUSS (SPACING NOT TO EXCEED 24' D.C.) A PURLIN TO BE LOCATED AT EACH BASE TRUSS JOINT. ATTACH PIGGYBACK TRUSS TO THE BASE TRUSS WITH 2' X 8' TEE -LOCK MULTI -USE CONNECTION PLATES SPACED 48'O.C. PLATES SHALL BE PRESSED INTO THE PIGGYBACK TRUSS AT 48' O.C. STAGGERED FROM EACH FACE AND NAILED TO THE BASE TRUSS WITH FOUR (4) 6d (1.5- X 0.099') NAILS IN EACH PLATE TO ACHIEVE A MAXIMUM UPLIFT CAPACITY OF 377 LBS. AT EACH 2' X 8' TEE -LOCK MULTI -USE CONNECTION PLATE. (MINIMUM OF 2 PLATES) ATTACH EACH PURLIN TO THE TOP CHORD OF THE BASE TRUSS. (PURLINS AND CONNECTION BY OTHERS) BASE TRUSS REFER TO ACTUAL TRUSS DESIGN DRAWING FOR ADDITIONAL BASE TRUSS INFORMATION. Antlmnj T TouR I11, RE. 6 64083 4451 % I.We 810, FOrtlk& :ft 34M JULY 17, 2017 1 TRUSSED VALLEY SET DETAIL - SHEATHED I STDTL05 4 . A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 VALLEYTRUSS (TYPICAL) SECURE VALLEY TRUSS W/ ONE ROW OF 10d NAILS 6' O.C. GABLE END, COMMON TRUSS, OR GIRDER TRUSS 01*01L11 GENERAL SPECIFICATIONS: 1. NAIL SIZE =3'X0.131'=10d 2. WOOD SCREW =4.5' WS45 LISP OR EQUIVALENT. 3. INSTALL SHEATHING TO TOP CHORD OF BASE TRUSSES. 4. INSTALL VALLEY TRUSSES (24' O.C. MAXIMUM) AND SECURE TO BASE TRUSSES AS PER DETAIL'A°. S. BRACE VALLEY WEBS IN ACCORDANCE WITH THE INDIVIDUAL DESIGN DRAWINGS. 6. NAILING DONE PER NOS -01. 7. VALLEY STUD SPACING NOT TO EXCEED 48' O.C. BASE TRUSSES ""^'.E END, COMMON 3S, OR GIRDER TRUSS TRUSS CRITERIA: WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05: 146 MPH WIND DESIGN PER ASCE 7-10: 170 MPH MAX MEAN ROOF HEIGHT = 30 FEET ROOF PITCH = MINIMUM 3/12 MAXIMUM 6/12 CATERGORY II BUILDING EXPOSURE WIND DURATION OF LOAD INCREASE: 1.60 MAX TOP CHORD TOTAL LOAD = 50 PSF ATTACH 2X4 CONTINUOUS 42 MAX SPACING = 24"O.C. (BASE AND VALLEY) SYP TO THE ROOF W/ TWO USP MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES. WS45 (1/4' X 4.5°) WOOD SCREWS INTO EACH BASE TRUSS. Anthony 7: Tomho 111, P.E. 0 80083 4451 St. Late Blvd. Fart Merte, FL 34946, FEBRUARY 5, 2018 1 TRUSSED VALLEY SET DETAIL I STDTL06 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 3494 772-009-1010 SECURE W/( VALLEY TRUSS (TYPICAL) GENERAL SPECIFICATIONS: 1. NAIL SIZE =3'X 0.131'=10d 2. WOOD SCREW = 3' WS3 USP OR EQUIVALENT. 3. INSTALL VALLEY TRUSSES (24' O.C. MAXIMUM)AND SECURE PER DETAIL 'A' 4. BRACE VALLEY WEBS IN ACCORDANCE WITH THE INDIVIUAL DESIGN DRAWINGS. 5. BASE TRUSS SHALL BE DESIGNED WITH A PURLIN SPACING EQUIVALENT — - - - - - — - - TO THE RAKE DIMENSION OF THE VALLEY TRUSS SPACING. - 6. NAILING DONE PER NOS- 01. GABLE END, COMMON 7. VALLEY STUD SPACING NOT TO EXCEED 4W O.C. TRUSS, OR GIRDER 7 TRUSS 1 DETAIL A (NO SHEATHING) N.T.S. BASE TRUSSES GABLE END, COMMON TRUSS, OR GIRDER P r2 VALLEY TRUSS TRUSS (TYPICAL) SEE DETAIL'A' BELOW (TYP.) WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05: 146 MPH WIND DESIGN PER ASCE 7-10: 170 MPH MAX MEAN ROOF HEIGHT= 30 FEET ROOF PITCH =MINIMUM 3/12 MAXIMUM 6/12 CATERGORY II BUILDING EXPOSURE WIND DURATION OF LOAD INCREASE: 1.60 MAX TOP CHORD TOTAL LOAD =50 PSF ATTACH 2X4 CONTINUOUSil2 MAX SPACING = 24' O.C. (BASE AND VALLEY) SYP TO THE ROOF W/ TWO USP MINIMUM REDUCED DEAD LOAD OF 8 PSF ON THE TRUSSES. WS3 (i/4' X 3-) WOOD SCREWS INTO EACH BASE TRUSS. ',ko 07T.cTwbP in, P.E 4 80083 4451SL Jude Blvd,. Fmt:Pi 'Fl 34946, JULY 17, 2017 I 1\VJJLV V/1LLL 1 JL 1 VL 1l11L (HIGH WIND VELOCITY) STDTL07 A-1 ROOF TRUSSES 4451 ST. LUCIE.BLVD. FORT PIERCE, FL 34M 772-409-1010 ATTA( WIND DESIGN PER ASCE 7.98, ASCE 74 WIND DESIGN PER ASCE 7-10: 170 MPF MAX MEAN ROOF HEIGHT = 30 FEET CATERGORY II BUILDING EXPOSURE B OR C WIND DURATION OF LOAD INCREASE:' MAX TOP CHORD TOTAL LOAD =50 PSI MAX SPACING = 24- O.C. (BASE AND VA SUPPORTING TRUSSES DIRECTLY UNL�.....�.�, - DESIGNED WITH A MAXIMUM UNBRACED LENGTH OF 2'- 10" ON AFFECTED TOP CHORDS. NOTES: 1. SHEATHING APPLIED AFTER INSTALLATION OF VALLEY TRUSSES. 2. THIS DETAIL IS NOT APPLICABLE FOR SPFS SPECIES LUMBER. FOR BEVELED BOTTOM CHORD, CLIP MAY BE APPLIED TO EITHER FACE. CLIP MAY BE APPLIED TO THIS FACE UP TO A NON-BEVELEDL I I MAXIMUM 6/12 PITCH NON -BEVELED BOTTOM CHORD BOTTOM CHORD CLIP MUST BE APPLIED TO THIS FACE WHEN PITCH EXCEEDS 6/12 (MAXIMUM 12112 PITCH) AAftny T. Tombo I11,.P.E. II ®0083. 4451 St..Luoe Blvd.. "P*C4e FL 34446 FEBRUARY 17, 2017 1 STANDARD GABLE END DETAIL I STDTL08 - TYPICAL 2X4 L-BRACE NAILED TO 2X4 VERTICALS V/10d NAILS, G' D.C. VIER STUI SECTION B-B A-1 ROOF TRUSSES 4451 ST. LUCIE SLVD. FORT PIERCE, FL 34945 772dOs-1010 TRUSS GEOMETRY AND CONDITIONS SHOWN ARE FOR ILLUSTRATION ONLY. DIAGONAL BRACE 4' - 0' D.C. MAX. SEE INDIVIDUAL ENGINEERING DRAWINGS FOR TRUSS DESIGN CRITERIA. 12 Q VARIES TO COMMON TRUSS * DIAGONAL BRACING ** L - BRACING REFER REFER TO SECTION A -A TO SECTION B-B V 24' MAX. NOTE: 1. MINIMUM GRACE OF #2 MATERIAL IN THE TOP AND BOTTOM CHORDS. 2. CONNECTION BETWEEN BOTTOM CHORD OF GABLE END TRUSS AND WALL TO BE PROVIDED BY PROJECT ENGINEER OR ARCHITECT. 3. BRACING SHOWN IS FOR -INDIVIDUAL TRUSS ONLY. CONSULT BLDG. ARCHITECT OR ENGINEER FOR TEMPORARY AND PERMANENT BRACING OF ROOF SYSTEM. 4. 'L' BRACES SPECIFIED ARE TO BE FULL LENGTH, SPF OR SP #3 OR BETTER WITH ONE ROW OF 10d NAILS SPACED 6' O.C. 5. DIAGONAL BRACE TO BE APPROXIMATELY 45 DEGREES TO ROOF DIAPHRAGM AT 4'-O' O.C. S. CONSTRUCT HORIZONTAL BRACE CONNECTING A 2X6 AND A 2X4 AS SHOWN WITH 16d NAILS SPACED 6' D.C. HORIZONTAL BRACE TO BE LOCATED AT THE MIDSPAN OF THE LONGEST GABLE STUD. ATTACH TO VERTICAL GABLE STUDS WITH (3) 10d NAILS THROUGH 2X4 (REFER TO SECTION A -A) 7 GABLE STUD DEFLECTION MEETS OR EXCEEEDS L/240 VERTICAL 2X6 SP DR SPF STUDVIBRACE #2 DIAGONAL BRACE (4) - 16d NAILS16d NAILS SPACED S' O.C. (2) lOd NAILS INTO 2XG2X6 SP OR _ _ _SPF #2 2X4 SP ORSPF #2L HORIZONTAL NAILED TO RTICALS SECTION A -A V/(4) - 10d NAILS PROVIDE 2X4 BLOCKING BETWEEN THE FIRST TWO TRUSSES AS NOTED. TOENAIL BLOCKING TO TRUSSES WITH (2) - 10d NAILS AT EACH END. ATTACH DIAGONAL BRACE TO BLOCKING WITH (5) - 10d NAILS (4) Ed NAILS MINIMUM, PLYWOOD SHEATHING TO 2X4 STD SPF BLOCK 12' MAX. B. THIS DETAIL DOES NOT APPLY TO STRUCTURAL GABLES. OIAG. BRACE 9. DO NOT USE FLAT BOTTOM CHORD GABLES NEXT TO SCISSOR TYPE AT 1/3 POINTS TRUSSES. IF NEEDED 10. 10d AND 16d NAILS ARE 0131'X3.0' AND 0131'X35' COMMON WIRE NAILS RESPECTIVELY. 11. SOUTHERN PINE LUMBER DESIGN VALUES ARE THOSE EFFECTIVE OS-01-12 BY SPIB/ALSC. MINIMUM STUD SIZE SPECIES AND GRADE STUD SPACING WITHOUT BRACE 2X4 L - BRACE DIAGONAL BRACE (2) DIAGONAL BRACES AT 1/3 POINTS MAXIMUM STUD LENGTH 2X4SP101STUD 12'0.C. 3-6-10 5&ll 6&11 11-1-13 2X4 SP#31 STUD 16'0.C. 3-3-10 4-9.12 6$-11 9.10-15 2X4SP931STUD 24'0.C. 2-6.6 3-11-3 5-4-12 6.1.2 2X4_SP #2 12' D.C. 3-10-15 5E-11 6-6-11 11-8-14 2X4SPa2 16'O.C. � 3.6-11 4-9-12 6-6-11 104_0 2X45P i2 24'0.C. 3-1-4 3-11-3 6-2-9 9-3-13 '-- DIAGONAL BRACES OVER 6' - 3' REQUIRE A 2X4 T-BRACE ATTACHED TO ONE EDGE. DIAGONAL BRACES OVER 12' - S' REQUIRE 2X4 I -BRACES ATTACHED TO BOTH EDGES. FASTEN T AND I BRACES TO NARROW EDGE OF DIAGONAL BRACE WITH 10d NAILS 6' O.C., WITH 3' MINIMUM ENO DISTANCE. BRACE MUST COVER SOX OF DIAGONAL LENGTH. T OR I BRACES MUST BE 2X4 SPF #2 OR SP #2. ROOF SHEATHING (2) - IDd NAILS TRUSSES @ 24' O.C. 2X6 DIAGONAL BRACE SPACED 413' O.C. ATTACHED TO VERTICAL WITH (4) - 16d NAILS, AND ATTACHED TO BLOCKING WITH (5) - 10d NAILS. HORIZONTAL BRACE (SEE SECTION A -A) END WALL FEET FEbRUARY 17, 2017 I WITH 2X BRACE ONLY I STDTL09 NOTES: T—BRACING/ I —BRACING TO BE USED WHEN CONTINUOUS LATERAL BRACING IS IMPRACTICAL. T—BRACE / I —BRACE MUST COVER SOX OF WEB LENGTH. THIS DETAIL NOT TO BE USED TO CONVERT T—BRACE / I —BRACE WEBS TO CONTINUOUS LATERAL BRACED WEBS. A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 NAILING PATTERN T—BRACE SIZE NAIL SIZE NAIL SPACING 2X4 OR 2X6 OR 2XB 10d 6' O.C. NOTE: NAIL ALONG ENTIRE LENGTH OF T—BRACE / I —BRACE (ON . TWO—PLY TRUSSES NAIL TO BOTH PLIES) BRACE SIZE FOR ONE —PLY TRUSS SPECIFIED CONTINUOUS ROWS OF LATERAL BRACING WEB SIZE 1 2 2X3 OR 2X4 2X4 T—BRACE 2X4 I —BRACE 2X6 2X6 T—BRACE 2X6 I —BRACE 2X8 2X8 T—BRACE 2X8 I —BRACE BRACE SIZE FOR TWO—PLY TRUSS SPECIFIED CONTINUOUS ROWS OF LATERAL BRACING WEB SIZE 1 2 2X3 OR 2X4 2X4 T—BRACE 2X4 I —BRACE 2X6 2X6 T—BRACE 2X6 I —BRACE 2XB 2X8 T—BRACE 2XB 1—BRACE T—BRACE / I —BRACE MUST BE SAME SPECIES AND GRADE (OR BETTER) AS WEB MEMBER. NAILS WEB NAILS I -BRACE NAILS WEB T-BRACE SECTION DETAILS FEBRUARY 17, 2017 LATERAL BRACING RECOMMENDATIONS I STDTL10 a AA ROOF TRUSSES - 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772 409-1010 TO MINIMIZE VIBRATION COMMON TO ALL SHALLOW FRAMING SYSTEMS, 2XG 'STRDNGBACK' IS RECOMMENOED, LOCATED EVERY 8 TO 10 FEET ALONG A FLOOR TRUSS. NOTE 1: 2X6 STRDNGBACK ORIENTED VERTICALLY MAY BE POSITIONED DIRECTLY UNDER THE TOP CHORD OR DIRECTLY ABOVE THE BOTTOM CHORD, SECURELY FASTENED TO THE TRUSS USING — OFTHE-METHODS-ILLUSTRATED-BELOW. ANY NOTE 2: STRDNGBACK BRACING ALSO SATISFIES THE LATERAL BRACING REQUIREMENTS FOR THE BOTTOM CHORD OF THE TRUSS WHEN IT IS PLACED ON TOP OF THE BOTTOM CHORD, IS CONTINUOUS FROM END TO END, CONNECTED WITH A METHOD OTHER THAN METAL FRAMING ANCHOR, AND PROPERLY CONNECTED, BY OTHERS, AT THE ENDS. USE METAL FRAMING ANCHOR TO ATTACH TO TOP CHORD BLOCKING BEHIND THE'VERTICAL WEB IS RECOMMENDED WHILE NAILING THE STRONGBACK INSERT WOOD SCREW THROUGH OUTSIDE FACE OF CHORD INTO EDGE OF STRDNGBACK (00 NOT ATTACH TO VERTICAL ATTACH TO VERTICAL USE DRYWALL TYPE SCREWS) VEB WITH (3) - 1Dd SCAB WITH (3) - 10d NAILS (0.131' X 3') NAILS (0131' X 3'). ATTACH TO VERTICAL WEB WITH (3) - 10d NAILS (0131' X 3') USE METAL FRAMING J Z ATTACH TO VERTICAL ANCHOR TO ATTACH WEB WITH (3) - 10d TO BOTTOM CHORD NAILS (0131' X 3') ATTACH 2X4 VERTICAL TO FACE OF TRUSS. FASTEN TO TOP AND BOTTOM CHORD WITH (2) - 10d NAILS (0131' X 3') IN EACH CHORD , ATTACH TO VERTICAL SCAB WITH (3) -, 10d NAILS (0131' X 3') TRUSS 2X6 4' - 0' WALL STRDNGBACK (TYPICAL SPLICE) (BY OTHERS) ATTACH TO CHORD WITH (2) #12 X 3' WOOD SCREWS (D.216' DIAD INSERT SCREW THROUGH OUTSIDE FACE OF CHORD INTO EDGE OF STRDNGBACK (00 NOT USE DRYWALL TYPE SCREWS) THE STRONGBACKS SHALL BE SECURED AT THEIR ENDS TO AN ADEQUATE SUPPORT, DESIGNED BY OTHERS. IF SPLICING IS NECESSARY, USE A 4' - G' LONG SCAB CENTERED ON THE SPLICE AND JOINED WITH (12) - IOd NAILS (0.131' X 3') EDUALLY SPACED. ALTERNATE METHOD OF SPLICING: OVERLAP STRDNGBACK MEMBERS A MINIMUM OF 4' - 0' AND FASTEN WITH (12) - 10d NAILS (0131' X 3') STAGGERED AND EQUALLY SPACED (TO BE USED ONLY WHEN STRDNGBACK IS NOT ALIGNED WITH A VERTICAL). BLOCKING (BY OTHERS) FEBRUARY17,2017 I LATERAL TOE -NAIL DETAIL I STDTL11 Al ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772409-1010 NOTES: 1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 45' WITH THE MEMBER AND MUST HAVE FULL WOOD SUPPORT (NAIL MUST BE DRIVEN THROUGH AND EXIT AT THE BACK CORNER OF THE MEMBER END AS SHOWN). 2. THE ENO DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 3. ALLOWABLE VALUE SHALL BE THE LESSER VALUE OF THE TWO SPECIES FOR MEMBERS OF DIFFERENT SPECIES. TOE -NAIL SINGLE SHEAR VALUES PER NOS 2001 (LB/NAIL) DIA SP OF HF SPF SPF-S .131 88.0 80.6 69.9 68.4 59.7 cs o .135 93.5 85.6 74.2 72.6 63.4 J .162 108.8 99.6 86.4 84.5 73.8 ri .12B 74.2 67.9 5B.9 57.6 50.3 co p .131 75.9 69.5 60.3 59.0- 51.1 J N .148 81.4 74.5 64.6 63.2 52.5 ri VALUES SHOWN ARE CAPACITY PER TOE -NAIL. APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED. EXAMPLE: (3) - 16d NAILS (0162' DIA. X 35') WITH SPF SPECIES BOTTOM CHORD FOR LOAD DURATION INCREASE OF 1.15: 3 (NAILS) X B45 (LB/NAIL) X 1.15 IDOL = 2915 LB MAXIMUM CAPACITY ANGLE MAY VARY FROM 30' TO 60' 45.00' ANGLE MAY VARY FROM 30' TO 60' THIS DETAIL IS ONLY APPLICABLE TO THE THREE END DETAILS SHOWN BELOW. VIEWS SHOWN ARE FOR ILLUSTRATION PURPOSES ONLY. SIDE VIEW (2X3) 2 NAILS NEAR SIDE NEAR SIDE SIDE VIEW C2X4) 3 NAILS FV7NEAR SIDE NEAR SIDE NEAR BIDE 45.00' SIDE VIEW (2X3) 2 NAILS NEAR SIDE NEAR SIDE NEAR SIDE NEAR SIDE ANGLE MAY VARY FROM 30' TO 60' 45.000 FEBRUARY17,2017 UPLIFT TOE -NAIL DETAIL STDTL12 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-4MI010 THIS DETAIL SHALL BE USED FOR A CONNECTION RESISITING UPLIFT FORCES ONLY. BUILDING DESIGNER IS RESPONSIBLE FOR LOADS IN OTHER DIRECTIONS. TOE -NAIL WITHDRAWAL VALUES PER NOS 2005 (LB/NAIL) DIA. SP OF HF I SPF SPF-S L7 .131 59 46 32 30 20 Z 0 - -J - .135- 60 - 48 - -- 33— 30— - 20- N .162 72 58 39 37 25 J 2 () .128 54 42 28 27 19 Z Z OJ .131 55 43 29 28 19 W .148 62 48 34 31- 21 J i ) J N Q M Z .120 51 39 27 26 17 z Z .12B 49 38 26 25 17 O .131 51 39 27 '26 17 .148 57 44 31 28 20 M7 NOTES: 1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 3D• WITH THE MEMBER AND STARTED1/3 THE LENGTH OF THE NAIL FROM THE MEMBER END AS SHOWN. 2. THE ENO DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 3. ALLOWABLE VALUE SHALL BE BASED ON THE SPECIE WITH LOWER NAIL CAPACITY BETWEEN THE TWO MEMBERS IN THE CONNECTION. VALUES SHOWN ARE CAPACITY PER TOE -NAIL. APPLICABLE DURATION OF LOAD INCREASES. MAY BE APPLIED. EXAMPLE: (3) - 16d NAILS (0162' DIA. X 3-9') WITH SPF SPECIES TOP PLATE FOR WIND DOL OF 1.33: 3 (NAILS) X 37 (LB/NAIL) X 133 (ODL FOR WIND) = 140 LB MAXIMUM ALLOWABLE UPLIFT REACTION DUE TO WIND FOR WIND DOL OF 1.60. 3 (NAILS) X 37 (LB/NAIL) X 1.60 IDOL FOR WIND) = 177 LB MAXIMUM ALLOWABLE UPLIFT REACTION DUE TO WINO IF THE UPLIFT REACTION SPECIFIED ON THE TRUSS DESIGN DRAWING EXCEEDS 147 LEIS (177 LBS) BUILDING DESIGNER IS RESPONSIBLE TO SPECIFY A DIFFERENT CONNECTION. USE (3) TOE -NAILS ON 2X4 BEARING WALL *� USE (4) TDE-NAILS ON 2X6 BEARING WALL NEAR SIDE FAR S L= TOP PLATE OF WALL VIEWS SHOWN ARE FOR ILLUSTRATION PURPOSES ONLY SIDE VIEW END VIEW FEBRUARY 5, 2016 TYP 2x2 NAILER ATTACHMENT STDTL13 4 J A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 1.0x4 W NAILER ATTACHMENT GENERAL SPECIFICATIONS MAX LOAD: 55 psf Roof Load, 170 mph, ASCE 7-10, 29'-0" Mean Height, Exp. B, C or D. April 11, 2016 TYPICAL ALTERNATE BRACING DETAIL I STDTL14 FO EXTERIOR FLAT GIRDER TRUSS A-1 ROOF TRUSSES 4451 ST..LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 (4) 12d TRUSS 2411 O.C. UPLIFT CONNECTION (SEE ROOF TRUSS) EXTERIOR FLAT GIRDER 12 VARIES (4) 12d MAX 3011 (21-611) 2x6 #2 SP (Both Faces) 2411 O.C. SIMPSON H5 Mfto T. Tambo III, P.E. a 80081 4451 SL L e fart Plm IL 34946 FE8i2UARY 17 2017 STANDARD REPAIR DETAIL FOR BROKEN CHORDS, WEBS, AND STDTL15 DAMAGED OR MISSING CHORD SPLICE PLATES —AA ROOF TRUSSES 4451 ST. LUCIE BLVD, FORT PIERCE, FL 34946 772-069-1010 TOTAL NUMBER OF NAILS EACH SIDE OF BREAK * X (INCHES) MAXIMUM FORCE (LES) 15% LOAD DURATION SP OF SPF HF 2X4 2X6 2X4 2X6 2X4 2X6 2X4 2X6 2X4 2X6 20 30 24' 1706 2559 1561 2342 1320 1980 1352 2028 26 39 30' 2194 3291 2007 3011 1697 2546 1738 2608 32 4B 36' 26B1 4022 2454 3681 2074 3111 2125 31B7 3B 57 40 3169 4754 2900 4350 2451 3677 2511 3767 44 66 48' 3657 5485 3346 5019 2829 '4243 2898 4347 • DIVIDE EQUALLY FRONT AND BACK ATTACH 2X_ SCAB OF THE SAME SIZE AND GRADE AS THE BROKEN MEMBER TO EACH FACE OF THE TRUSS ( CENTER ON BREAK OR SPLICE) WITH IOd NAILS (TWO ROWS FOR 2X4, THREE ROWS FOR 2X6)SPACED' 4' O.C. AS SHOWN (131' DIA. X 3'). STAGGER NAIL SPACING FROM FRONT FACE AND BACK FACE FOR A NET 2' D.C.,SPACING IN THE MAIN MEMBER. USE A MIN. 3' MEMBER ENO DISTANCE. THE LENGTH OF THE BREAK (C) SHALL NOT EXCEED 12'. (C=PLATE LENGTH FOR SPLICE REPAIRS) THE MINIMUM OVERALL SCAB LENGTH REOUIREO (L) IS CALCULATED "AS FOLLOWS: L = (2) X + C • 10d NAILS NEAR SIDE + IOd NAILS FAR SIDE BREAK 6' MIN THE LOCATION OF THE BREAK MUST BE GREATER THE REQUIRED X DIMENSION FROM ANY PERIMETER AND A MINIMUM OF 6' FROM ANY INTERIOR JOINT DO NOT USE REPAIR FOR JOINT SPLICES NOTES: 1. THIS REPAIR DETAIL IS TO BE USED ONLY FOR THE APPLICATION SHOWN. THIS REPAIR DOES NOT IMPLY THAT THE REMAINING PORTION OF THE TRUSS IS UNDAMAGED. THE ENTIRE TRUSS SHALL BE INSPECTED TO VERIFY THAT NO FURTHER REPAIRS ARE REQUIRED. WHEN THE REQUIRED REPAIRS ARE PROPERLY APPLIED, THE TRUSS WILL BE CAPABLE OF SUPPORTING THE LOADS INDICATED. 2. ALL MEMBERS MUST BE RETURNED TO THEIR ORIGINAL POSITIONS BEFORE APPLYING REPAIR AND HELD IN PLACE DURING APPLICATION OF REPAIR. 3. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 4. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO AVOID LOOSENING OF THE CONNECTOR PLATES AT THE JOINTS OR SPLICES. 5. THIS REPAIR IS TO BE USED FOR SINGLE PLY TRUSSES IN THE 2X_ ORIENTATION ONLY. S. THIS REPAIR IS LIMITED TO TRUSSES WITH NO MORE THAN THREE BROKEN MEMBERS. TRUSS CONFIGURATION AND BREAK LOCATIONS FOR ILLUSTRATIONS ONLY THAN OR EQUAL TO BREAK OR HEEL JOINT (SEE SKETCH ABOVE). FEBRUARY 17, 2017 1 SCAB APPLIED OVERHANGS 1 STDTL16+` ' AA ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-4M1010 TRUSS CRITERIA: LOADING: •40-10-0-10 DURATION FACTOR: 115 SPACING: 24. O.C. TOP CHORD: 2X4 OR 2X6 PITCH: 4/12 - 12/12 HEEL HEIGHT: STANDARD HEEL UP TO 12' ENERGY HEEL ENO BEARING CONDITION NOTES: 1. ATTACH 2X_SCAB (MINIMUM #2 GRADE SPF, HF, SP, OF) TO ONE FACE OF TRUSS WITH TWO ROWS OF IOd COMMON WIRE NAILS (14B' OIA. X 3') SPACED 6' O.C. 2. THE ENO DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 3. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO AVOID LOOSENING OF THE CONNECTOR PLATES AT THE JOINTS OR SPLICES. 2X SC NOTE: TRUSS BUILT WITHOUT AN OVERHANG. THIS DETAIL IS NOT TO BE USED WHEN OVERHANG HAS BEEN BROKEN OFF. lnl.1;irakill THIS DETAIL TO BE USED ONLY WITH TRUSSES (SPANS LESS THAN 40') SPACED 24' O.C. MAXIMUM AND HAVING PITCHES BETWEEN 4/12 AND 12/12 AND TOTAL TOP CHORD LOADS NOT EXCEEDING 50 PSF. TRUSSES NOT FITTING THESE CRITERIA SHOULD BE EXAMINED INDIVIDUALLY.