Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 FLORIDA ENERGY,EFFI•CIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT SCANNED Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY BY City, State, Zip: FT. PIERCE, FL, - Permit Number: ry¢� S88`, Ll1CI@LJ /�l ®U)/S)/ / Owner: \ ��Or Q�S-1 Jurisdiction: Design Location: FL, FortPierce _ _ County_ --St. Lucie (Florida. Climate Zone 2). 1. New construction or existing New (From Plans) 9. Wall Types (1432.0 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1224.00 ft2 b. Frame - Wood, Adjacent R=11.0 208.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? Yes 10. Ceiling Types (1753.0 sgft.) Insulation Area a. Under Attic (Vented) R=30.0 1753.00 ft2 6. Conditioned floor area above grade (ft2) 1753 b. WA R= ft2 Conditioned floor area below grade (ft� 0 c. N/A R= ft2 11. Duds R ftz 7. Windows(151.4 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 250 a. U-Factor. Sgl, U=0.63 111.36 ft2 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.65 40.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor N/A ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 2.850 ft. Area Weighted Average SHGC: 0.239 14. Hot water systems 8. Floor Types (1753.0 sgft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ft' b. Conservation features EF: 0.970 b. WA R= ft2 None c. WA R= ft2 15. Credits Patel Total Proposed Modified Loads: 52.93 Glass/Floor Area: 0.086 p SS PASS Total Baseline Loads: 53.85 Fi 1 hereby certify that the plans and specifications covered by Review of the plans and STq?A this calculation are in compliance with the Florida Energy specifications covered by this O4gIiE Code. calculation indicates compliance with the Florida Energy Code. f+ rnrt ?K••:, ;;`.;. °, O PREPAR D BY: Before construction is completed r. DATE: this building will be inspected for O y compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. y� with the Florida Energy Code. �''Op WE OWNER/FjG(E BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. ��pp�� - Compliance requires an Air Barrier and Insulation Inspection Checklist in accar ��o��gg�gg®.i�latlQis project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 ( r�2. fi f®��LIAF CE CO® at4TY 4 S'To LU 0 qJ BOCC 11/19/2018 3:12 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE THE WINDSOR IMP Bedrooms: 3 Address Type: Street Address _ Building Type: User Conditioned Area: 1753 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 225 Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) - Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1763 14024 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 MASTER BEDROO 224 1792 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 MASTER BATH 56 448 No 0 1 Yes Yes Yes 4 M. BATH 61 488 No 0 1 Yes Yes Yes 5 LAUDRY 36 288 No 0 1 No Yes Yes 6 BEDROOM 2 180 1440 No 0 1 1 Yes Yes Yes 7 DINING/GREAT R 588 4704 No 2 1 Yes Yes Yes 8 KITCHEN 209 1672 Yes 0 1 Yes Yes Yes 9 BATH 50 400 No 0 1 Yes Yes Yes 10 HALL 25 200 No 0 1 No Yes Yes 11 FOYER 92 736 No 0 1 Yes Yes Yes 12 BEDROOM 3 169 1352 No 0 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio MASTER BEDRO 37 ft 0 224 ft' __ 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 ft' ___ 0 1 0 3 Slab -On -Grade Edge Insulatio MASTER BATH 8 ft 0 56 ft' ___ 0 1 0 4 Slab -On -Grade Edge Insulatio M. BATH 7 ft 0 61 ft' ___ 0 1 0 5 Slab -On -Grade Edge Insulatio LAUDRY t ft 0 36 ft' 0 1 0 11/19/2018 3:12 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 6 FORM R405-2017 INPUT. SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 6 Slab -On -Grade Edge Insulatio BEDROOM 2 12 It 0 180 ft' 0 1 0 7 Slab -On -Grade Edge Insulatio DINING/GREAT 50 ft 0 588 ft' 0 1 0 B Slab -On -Grade Edge Insulatio KITCHEN lift 0 209 ft' 0 1 0 9 Slab -On -Grade Edge Insulatio BATH 5 ft 0 50 ft =__ 0 1 0 16SIab-On-Grade Edge Insulatio HALL 1 It 0 25 ft' ___ 0 1 0 11SIab-On-Grade Edge Insulatio FOYER 9 It 0 92 ft' ____ 0 1 0 12SIab-On-Grade Edge Insulatio BEDROOM 3 14 ft 0 169 ft' __ 0 1 0 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1847 ft' 292 ft' Light 0.6 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1763 fF N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) MASTER BEDRO 30 Blown 224 ft' 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft' 0.1 Wood 3 Under Attic (Vented) MASTER BATH 30 Blown 56 ft' 0.1 Wood 4 Under Attic (Vented) M. BATH 30 Blown 61112 0.1 Wood 5 Under Attic (Vented) LAUDRY 30 Blown 36 ft' 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 180 ft' 0.1 Wood 7 Under Attic (Vented) DINING/GREAT 30 Blown 588 ft' 0.1 Wood 8 Under Attic (Vented) KITCHEN 30 Blown 209 ft' 0.1 Wood 9 Under Attic (Vented) BATH 30 Blown 50 ft' 0.1 Wood 10 Under Attic (Vented) HALL 30 Blown 25 ft' 0.1 Wood 11 Under Attic (Vented) FOYER 30 Blown 92 ft' 0.1 Wood 12 Under Attic (Vented) BEDROOM 3 30 Blown 169 ft' 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 0 1 NE=>W Exterior Concrete Block - Ext InsMASTER BE 4.1 16 0 8 0 128.0 ft' 0 0 0.4 0 2 SW=>E Exterior Concrete Block - Ext InSdWSTER BE 4.1 7 0 8 0 56.0 ft' 0 0 0.4 0 3 NW=>S Exterior Concrete Block - Ext InAMSTER BE 4.1 14 0 8 0 112.0 ft' 0 0 0.4 0 4 NE=>W Exterior Concrete Block - Ext InsMASTER BA 4.1 8 0 8 0 64.0 ft' 0 0 0.4 0 11/19/2018 3:12 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 6 WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 0 5 NE=>W Exterior Concrete Block - Ext InsuM. BATH 4.1 7 0 8 0 56.0 1`12 0 0 0.4 0 6 NE=>W Exterior Concrete Block - Ext IndMDROOM 2 4.1 12 0 8 0 96.0 ft2 0 0 0.4 0 7 SW=>E Exterior Concrete Block - Ext IndWNING/GRE 4.1 30 0 8 0 240.0 ft2 0 0 0.4 0 8 NW=>S Exterior Concrete Block - Ext InQINING/GRE 4.1 20 0 8 0 160.0 ft2 0 0 0.4 0 _ 9 SW=>E Exterior Concrete Block - Ext InsuKITCHEN 4.1 11 0 8 0 88.0 ft2 0 0 0.4 0 -_ - _> -Exterior --Concrete Block = EzFlnsul� BATH- -- 4.T- -- -5 -- -0 --8 0 0 ft 40.' 0 0 ----- 0.4 - - 0 11 SE=>N Exterior Concrete Block - Ext Insul FOYER 4.1 8 0 8 0 64.0 ft2 0 0 0.4 0 12 SW=>E Exterior Concrete Block - Ext Insul FOYER 4.1 1 0 8 0 8.0 ft2 0 0 0.4 0 13 NE=>W Exterior Concrete Block - Ext InRFDROOM 3 4.1 13 0 8 0 104.0 ft2 0 0 0.4 0 14 SW=>E Exterior Concrete Block - Ext Infi EDROOM 3 4.1 1 0 8 0 8.0 ft2 0 0 0.4 0 15 N=>SW Garage Frame - Wood BEDROOM 3 11 26 8 208.0 ft2 0.23 0.4 0 01614 a1 # Omt Door Type Space Storms U-Value Width Height Area I Ft In Ft In 1 SE=>N Insulated FOYER None .39 3 3 6 8 21.7 ft2 / Wall V # Ornt ID Frame Panes 1 NW=>S 3 Metal Low-E Single 2 NE=>W 5 Metal Low-E Single 3 NE=>W 6 Metal Low-E Single 4 SW=>E 7 Metal Low-E Single 5 NW=>S 8 Metal Low-E Single 6 NE=>W 13 Metal Low-E Single 1 # Scope 1 Wholehouse Floor Area 806 ft2 Method Proposed ACH(50) piling Area 806 ft2 SLA .000356 Yes Yes Yes Yes Yes Yes WINDOWS entered orientation J-Factor SHGC 0.63 0.25 0.63 0.25 0.63 0.25 0.63 0.25 0.65 0.21 0.63 0.25 GARAGE Xposed Wall Perim, 26 ft INFILTRATION CFM 50 ELA 1636.1 89.82 N N N N N N Overhang Area Depth Separati 32.4 ft2 1ftOin 1ft4in 6.9 ft2 1ft0in 1ft4in 16.2 ft2 1ft0in 1ft4in 39.8 ft2 1ft0 in 1ft4 in 40.0 ft2 8ft0in tft4 in 16.2 ft2 1ft0in 1ft4 in 8ft Int Shade Screening Drapes/blinds Exterior 5 None None None None None None None None Drapes/blinds Exterior 5 Wall Insulation 11 EgLA ACH ACH 50 168.92 .2578 7 11/19/2018 3:12 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 6 FORM R405-2017 INPUT SUMMARY CHFCKI IST RFPnRT HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 HOT WATER SYSTEM --- - - -- - --- ----- ---- ---- # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None f1= DUCTS / — Supply — — Return — Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 250 ft- Attic 75 ftz Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling Heat Jan Feb Jan Feb Mar Mar HX AprApr € r [X] Jun [X] Jul May Jun [X] Aug Aug [X] Sep Sep [ ] [ ] Oct N [fX,] Nov Dec Dec H Vent ng Jan l l Feb Mar Apr May I[[ 1]1] tt ]]Jul Jun Jul [[ 11 Aug [t ]] Sep [Xl Oct [X] Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 11/19/2018 3:12 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 6 I-UKIVI K4U0-ZU1 / IIVPU I JUMMARY GMEGKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft° 0 ft 0.3 MASTER BEDROO Default(8 lbs/sq.ft. ft' ft 0.3 WIC Default(8 Ibs/sq.ft. ft' ft 0.3 MASTER BATH Default(8 Ibs/sq.ft. ft' ft 0.3 M. BATH Default(81bs/sq.ft. ft' ft 0.3 LAUDRY _ Default(8 Ibs/sq.ft._ _ _ _ _ _ _ ft' _ _ ft 0.3. _ .BEDROOM 2_ _ Default(8 Ibs/sq.ft. ft' ft 0.3 DINING/GREAT R Default(8 Ibs/sq.ft. ft' ft 0.3 KITCHEN Default(8 lbs/sq.ft. ft' ft 0.3 BATH Default(8 lbs/sq.ft. ft' ft 0.3 HALL Default(8 lbs/sq.ft. ft' ft 0.3 FOYER Default(8 Ibs/s .ft. ft' ft 0.3 BEDROOM 3 Name: Test Rater Signature: G Rating Compant: Test Rater Date: 11/19/2018 3:12 PM EnergyGauge® USA Section R406.4.1 Compliant Software Page 6 of 6 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y Owner: Jurisdiction: U w Design Location: FL, Fort Pierce c=i COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking,or floor framing cavity g insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind ponina and Wrino Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire snrinkler cover nlates and walls or r�ilinos a. m awnwn, inspecnon or log wails shall De In accordance with the provisions or IGU-40u. 11/19/2018 3:12 PM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location AttictAttic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 34.8 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER c) Ground/water source SEERICOP 6. Conditioned floor area (sq. ft.) 6. 1753 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.635 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.239 c) Area 7c. 151.4 8. Skylights a) U-factor:(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 14. Heating system: Capacity 34.8 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF c) Electric resistance COP d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE 0 Other 9a. 0.0 9b. 15. Water heating system 9c. a) Electric resistance EF 0.97 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF 10A1. e) Dedicated heat pump with tank EF 10A2. 4.1 0 Heat recovery unit HeatRec% g) Other 10131. 11.0 110132. 16. HVAC credits claimed (Performance Method) a) Ceiling fans 11a. 30.0 b) Cross ventilation No 11 b. c) Whole house fan No 11c. d) Multizone cooling credit 11d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature:_-- Date: � Address of New Home: THE WINDSOR \ - \� �!Q� (t City/FL Zip: PIERCE-FC��` 11/19/2018 3:12:35 PM EnergyGauge® USA 6.0.02. FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 wrightsoft= Protect Summary Entire House QUICK CALCS, INC. 317 ST. LUCIE LR, FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-67S6 Email: For. WYNNE DEVELOPMENT \THE`WINDSOR, FT. PIERCE, FL Notes: Job: Date: By: SCANNED 13Y t_tude County Design Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TO 28 OF Design TO 15 OF Daily range L . Relative humidity 50 % Moisture.difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 18467 Btuh Structure 17655 Btuh Ducts 6190 Central vent (0 cfm) 0 Btuh Btuh Ducts Central vent (0 cfm) 9340 Btuh 0 Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 24657 Btuh Use manufacturer's data n Infiltration Ratelswingg multiplier Equipmenfsensible load 0.95 25645 Btuh Method Simplified Construction quality Average Latent Cooling Equipment Load Sizing Fireplaces 0 Structure 2453 Btuh Ducts 2554 Btuh Central vent (0 cfm) 0 Btuh Heat"'gg Area Coal' (none) (ft2) 1753 1753 Equipment latent load 50Q7 Btuh Volume (fta) 14741 14741 Airchangeslhour 0.38 0.20 Equipment total load 30652 Btuh Equiv. AVF (cfm) 93 49 Req. total capacity at 0.70 SHR 3.1 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Model 25HBC536A'030 AHRI ref 7914585 Efficiency Heating input Heating output Temperature rise Actual airflow Airflow factor Static pressure Space thermostat Capacity balance point = 34 OF 8.5 HSPF 34600 Btuh @ 470F 27 OF 1160 cfm 0.047 cfm/Btuh 0.50 in H2O Backup: Input = 7 kW, Output = 23009 Btuh, 100 AFUE Make Cartier Trade CARRIER AIR CONDITIONING Cond 25HBC536MO30 Coil FX4DN((B,F)037 AHRI ref 7914585 Efficiency 12.0 EER, 15 SEER Sensible cooling 24360 Btuh Latent cooling 10440 .Btuh Total cooling 34800 Btuh Actual airflow 1160 cfm Air flow factor 0.043 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.84 Calculations approved byACCAto meet all requirements of Manual J 8th Ed + wrightsofC RightSuite® universal 291E 17.0.14 RSU06101 2o17-Apr-10 nn9:2e ...k Calcs\Documents\WYNNE-THE WINDSOR-REVISm.mp Cale = MJS Front Doorfaces: N Page 1 wrightsoft• Right- J@ Worksheet Job: Entire House Date: QUICK CALCS, INC. By- 317 ST. LUCIE LR, FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772A6"796 Emil: QUICKCALCS AOL.COM 1 Room name Entire House MASTER BEDROOM 153.0 ft 45.0 ft 3 Room hell height 8.4 ft of 8.0 ft heat/cool 4 Room dimensions 1.0 x 290.0 It 5 Room area 1763.0 ft' 280.0 ft' Ty Construction U-telue Or HTM Area (ftj Load Area (ft') Load number I (Btu1VWF) (Btulvftz) or perimeter (ft) (etuh) or perimeter ft () (Btuh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 13A4ocs - 0.143 ne 4.10 261 488 448 1795: 1141 192 192 769 489 Uc1om , 1270 ne --35.56 70.43 7 0. - 247: 488 0:: 0 0 1Ac1om <_ 1270 ne 35.56 '. ` 70.43 " - 16 , 0 - 581 1151 `0 � 0 -- 0 0 .1Ac1om-. 1.270 -ne. -''35.56 - 45.24 .. 16: 6 `: 581 AS � 0'. 0 ' .0 ... 0 11 W 13A-0ocs 0.143 se 4.00 255 64 41 165 105 0 0 0 - o �D 71D0 0.390 se - 10.92 11.31 23 23 248 257 0 0 0 0 4y 13A4acs ;•: - <.0.143 sw '. 400 -. 2.55 - - .437 .396 '1584 - :- 1007 . -56 56:- } 224 i - : 143 G 4As2mn �: 0.770 -sw� s1.56 ".'27(53 ,' . ai � ��..4s - . -ss3 " � 1140 _- � o . _ �0 - _. , o � �It/--� 13AAocs 0.143 nw 4.00 255 290 217 867 551 112 79 318 202 1Ac1om 1.270 nw 35.55 45.24 33 0 1162 1478 33 0 1162 1478 �--G - 4A5-2anG ' 0.770 nw 21.56 36.90 41 0 880 1505 0 0 0 0 R - S12C41svr =- . -0.091 - +..'. 265 - - 1128 308 : 'Wll - 784 - 395 : -0 ... - "0 ' .'. 0 , c 16A30md -: 0.032 - 0.90 232 1753 1753 - 1571 4067 260 280 .. 251 .0 650 rF' . 22A-tpl .. 0.989 - - 27.69 `_ = 0.00 1763 -153 4237 0 .280, - , 45 �1246 : ' D 6 c)AED excursion 1360 600 Ernelope loss/gain 15594 15385 1 3970 3561 12 a) Infiltration 2873 810 S09 228 b) Roomventdation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances/other 1000 0 Subtotal @hoes 6 to 13) 18w 17655 4779 3789 Less erdernal load 0 0 0 D Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 18467 17665 4779 3789 15 Duct loads 34% 53% 6190 9340 34Y.1 63% 1602 2005 Total room load 24657 26995 1 63010 579q Air required(cfm) 1160 1160 300 2i9 / -A wrightsoft- RlghtSuiteO Universal 2017 17.0.14 RSU08101 ... k Calcs\Documents\WVMVE-THEWINDSOR-REVISED.mp Calc=MJB Front Doorfaces: 2017-Apr-10 17:19.28 Page 1 F wrightsoft- Right-JO Worksheet Job: Entire House Date` QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 7724665799 Fax 772-4665796 Emit; OUICKCALCS@AOL.COM 1 Room name WIC M. BATH 2 Sgwsed wall 0 It 7.0 ft 3 Room height SO It heallcool 8.0 ft heaVcool 4 Room dimensions 7.0 x 9.0 It 1.0 x 61.0 It 5 Room area 63.0 W 61.0 W Ty Construction U-value Or HTM Area (ft°j Load Area (" Load number (Btut✓ft-F) (Btuh(ftj or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP(S Heat Cool Gross I WP/S Heat Cool 6 13AAMs 0143 ne 400 255 0 0 0 0 56 49 196 125 -tAclom .1270 -ne. :35.56 ,70.43 0 0 0 - 0 .7 - "0 ` 247 <48tt 1A019m �1270 ne -_''35.56 . ' 70.43 . 0 ' . 0....: _ 0 0 0- 0, 0 ;0 •'1.270. ne '-35.56 .'45:24 -... 0 0 ':. 0?� 0 0.. - 0'. 0 11 V7/ 13A4= 0.143 se 4.00 255 0 0 . 0 0 0 0 0 0 �D 11DO 039) se 1092 11.31 0 0 0 0 0 0 0 0 13A-0ocs ; .: .5.0.143 . sw- 400 , ._255 , 0 -i 0'-.:. 0 ; 0 - 0 0 .- 0 - - -:: o '4AS2arn _ ;0.770 , sw' '•21.56 27i53 . ' 0 .. 0 ' . 0 _ '. - 0 13AAoes 0.143 nw 4.00 255 0 0 0 0 ..0'. 0 „0 0 0 0 1Aclom 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 �--(3 4AS-2anp 0.770 my 21.56 36.90 0 0 0 0 0 0 0 0 P--:::12C-0siv, .i" '0091 -'.":_"255'.. 1.28 _ :0 ..0, :0 0 ". ,M j.0 ..:.. 0:„.:( =;"0 C 16A30md 0.032 - 0.90 232 63 63 66 146 61 61 55 - 142 F .$..22A-tpl_ ... 0.989 -- -27.69 :: ;'0.00 .r63 - ..0 sp'. .. 0 61, -.7- 194 •. -..0. 6 c)AED excursion -5 -26 Envelope loss/gain 56 141 6921 729 12 a) Infiltration 0 0 126 35 b) Room ventilation 0 0 0 0 13 trderk gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 56 - 141 817. 764 Less etdemal load 0 0 .0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 56 141 817 764 15 Duct loads 34°� 53% 19 75 34% 5330 274 404 Total rcorn load 75 216 - 1091 1168 Air required (ofm) 4 9 51 60 Calculations approved byACCA to meet all requires A Wrrightsoft' RightSufte® Universal 201717.0.14 RSU08101 ...k CaicsWocumentslWYNNE-THE WINDSOR-REVISED.rup Cole =MJ8 Front Door faces: N 2017-Apr-10 17:19:28 Page 2 wrightsoft Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC: By: 317 ST. LUCIE LM, FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Emil: QUICKCALCS@AOL.COM 1 Room name LAUDRY BEDROOM 2 ed wall 0 ft 12.0 ft 3 Room 9h 8.0 ft heatfocol 8.0 ft heat/cool 4 Room dimensions 6.0 x 6.0 It 15.0 x 120 ft 5 Room area 36.0 ft- 180.0 ft' Ty Construction U-value Or HTM Area Load kea number I (Btuh/ftk°F) (Btuh/fN) or perimeter (ft) (Btuh) or perimeter (ft) ((Btuh) Heat I Cool Gross MRS Heat Cool Grass WP/S Heat Cod 6 13A-0ocs 0143 ne 400 2-65 0 0 0 0 96 80 319 203 1Actom ' -. ,.. .1 270 no, : 3556 •- 70.43' - 0 0 '0 - 0 t 0 > o i°. 0 .. ,:.0 1Ac1om . 1.270 no ,3556 ? 70.43 " 0 0' ' •0 0 -.- 16 0 4581 1151 1Aclonn.' 1:270 no 35.56 45.24 - - 0 0- 0 0 0 0 0 s 0 11 yl 13A-4= 0.143 se 4.00 265 0 0 0 0 0 0 . 0 0 -D 11D0 0390 se 10.92 11.31 0 0 0 0 0 0 0 0 0143 ,sw' . `4.00 255 ,0.. 0 0 0 0.. .0 : ., 0., - '0 4AS2om-` 0770 sw; ,.21.56 `27.53 '- 0 0 0 0 - 0' -0 - ;.0- S0 �If1--� 13A-4= 0.143 nw 4.00 255 0 0 0 0 0 0 0 0 1Aclom 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 T--G 4AS2omd 0.770 nw 21.56 36.90 0 0 0 0 0 0 0 0 P"-:,-_12C-0Sw- _. `0.091 '- "256' '1.28 :, 0 .0 0. 0- 0 ,. :0'. ..0. •0 C 16A30md '22A-ipl 0.032 - 0.90 232 36 36 32 84 180 ISO 161 418 F •. :' a.0:889- -' 27.69 0.00 36.- 0 0 01. 180 .°12 .. 332 .a:. 0 6 c)AED excursion 3 -60 Envelope loss/gain 32 81 1394 1711 12 a) Infiltration 0 0 216 61 b) Room ventilation 0 0 0 0 13 Wemal gains: Occupants @ 230 D 0 0 0 Appliances/other 0 0 Subtotal Quies 6 to 13) 32 81 16D9 1772 Less wdemal load 0 0 0 Less transfer 0 0 0 Redisbib tlon 6 14 6 14 Subtotal 38 85 1615 15 Dud loads 34% 63% 13 50 34% 63% 541 JZ730 Total room load 51 145 2156 Air required(cfm) 2 6 101 .�A -PpF wrightsoft- RightSuite® Universal 2017 17.0.14 RSU08101 ... k Calca\Documents\WYNNE-THE WINDSOR-REVISED.mp Calc = MJ8 Front Door faces: 2017-Apr-10 17:19:28 Page 3 wrightsoft, Right-J® Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: T72-466-6799 Fax 772-466-6796 Emil: OUICKCALCS@AOLCOM 1 Room name DINING/GREAT ROOM IQiCHEN Eqosed 50.0 ft 11.0 it 3 Roorn heill ght 8.9 It heat/cool 8.9 ft heat(cuol 4 Room dimensions 1.0 x 588.0 ft 19.0 X 11.0 If 5 Room area 688.0 ft2 209.0 ft2 Ty Construction U-value Or HTM Area Lead number I (Btuwfti°F) @WlVft2) or perimeter (ft) (Btuh) oorr�pen ter (ft) (Btuh) Heat Cool Gross N/PIS Heat Cool Gross N/PIS Heat Cool 6 V 1M4ocs 0143 no 4.00 255. 0 0 0 0 0 0 0 . 1Ao1om .- .. 1 270 ne 3556 _70.43 0 �0 - 0 0 0 -01 0 .0 . 0 1Ac1am =, -- 1 270 no .:. 3556 70.43 0 D - 0 - 0 0 , - '.0 0 „ .0 1Ac1om 1.270 ne "3556 :.45.24 0 0 ��O 11 VI/ 13A4ccs 0.143 se 4.00 255 0 0 0 0 0 0 0 0 �—D 11130 0.390 se 1092 11.31 0 0 0 0 0 0 0 0 Vj1 13A4ocs>:- _' 0.143 sw: , 400 - , . 255 267 226 ` • --.:. -903 -. - 574 - '.98 I. ' . - 98 392 -,249 LC: 4A5-torn - 0.770 Fsw - 21.56 -'�27:53 41 .22 893 �: 1140 ' o - 0 0 0 IAclom 1.270 nw 35.55 45.24 0 0 0 0 0 0 0 0 �--G ' 4A5-2and 0.770 nw 21.56 36.90 41 0 880 1505 0 0 0 0 P =: -12C-0sw�i .._ 0.091 -.- 255' 1:28 •0 0' - 0 -0 116 • 116 . 29 '148 C _ i6A30md 0.032 - 0.90 2-32 588 588 527 1364 209 209 187 485 F 22Atpl ,.. 0.989 - -- 27.69 . 0.00.. 588 .. 50 - - 1385 : 0 209 - -_ 11 w - 305 6 o)AED excursion 1004 -64 Envelope loss/gain 5136 5937 11179 818 12 a) Infiltration 1000 282 220 62 b) Room ventilation 0 0 0 0 13 Kenna] gains: Occupants @ 230 2 460 0 0 Appliances/other 0 1000 Subtotal Pines 6 to 13) 613B 6679 1399 1880 Less a Beard load 0 0 0 0 Less transfer 0 0 0 0 Redstribution 6 14 0 0 14 Subtotal 6142 6693 1399 1880 15 Duct loads 34% 53% 2058 3541 34% 53% 469 995 Total room load 8200 10234 1867 2875 Air required (cfm) 386 440 88 12A Calculations approved bvACCA to meet all requirements of Manual J 8th Ed �-1- wrightsofY Right -Suite® Unlwrsal .RSU06191 2017-Apr017:19:28 .A ...k Calcs0ocumentslWYNNE-THE WINDSOR-REVISED.mp Calt=MJB Front Door faces: N Page + wrightsofe Right-JO Worksheet Job: Entire House Date: QUICK C%1LCS, INC. By: 317 ST. LUCIE I-M. FT. PIERCE, FL 34946 Phone: 772-46"799 Fax 772A66-6796 Email: QUICKCALCSQAOL.COM 1 Room name BATH HALL 2 F)gnsed wall. 5.0 ft 0 It 3 Roam height 8.0 ft heaU000l 8.0 ft heatfcool 4 Room dimensions 10.0 x 5.0 ft 5.0 x 5.0 It 6 Room area 50.0 ft. 25.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft Load number (Btulvftc°F) (Btulvft2) a perimeter (ft) (Btuh) or perimeter (ft) (Btuh Heal Cool Gross WPlS Heat Cool Gross NOS Heat Coal 6 134-0ocs 0.143 no 400 255 40 40 160 102 0. 0 0. 0 itAclon 1.270 ne -3556 - 70.43 0 0 D 0 - 0, 0 1Aclq :1.270 no,' :, 3566 . 70.43 -,0 S 0 -' ^ ;0. ,0 10 ' 0.:, 0' ilAcianc 1.270 "ne 35.56 ' 45.24 0 0' _ 0 - 0 0:. .0 0 '` 0-'•-0 .:0 11 W 13A4ocs 0.143 se 4.00 255 0 0 0 0 0 0 0 0 0.39D se 1092 11.31 0 0 0 0 0 0 0 0 yy L=G- '13A-0ocsla-0:143 sw, ` =400 �..-255 0 .. .. 0' .- - "0:.: - .:0 ,; '.0' 0 0 0 ;0 4AS2am : ' 0.770 x sw - . 2156 - °.27.53 0 '.' -0 - 0 - - 0 0 0 0 r ' l,N 13A-0ocs 0.143 nw 400 2.65 0 0 0 0 0 0 0 0 1Ac1om 1.270 nw 3556 45.24 0 0 0 0 0 0 0 0 `- 4A5-2amd 0.770 nw 21.66 36.90. 0 0 0 0 0 0 0 0 P ^'. .]2C-0sW' 0.091 = 255 ' -1.28 0 .0 0 0 . - 0 - -0 0 0 C 16A30md 0.032 - 0.90 232 50 50 45 116 25 25 22 58 -F 22A-tpl.- 0.989 - 27.69 : -0.00 50 5 138 -' 0 25 . 0 :. 0 - 10 6 c)AED excursion -e -2 Envelope loss/gain 343 210 22 56 12 a) Infiltration 90 25 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants oQ 230 0 0 0 0 Applianoeslother 0 0 Subtotal Qines 6 to 13) 433 235 22 56 Less mdernal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 14 -22 -W 14 Subtotal 439 249 0 0 15 Duet bads 341/5 53% 147 132 34% 53% 1 0 0 Total room load I 586 381 0 0 Air required(cfm) 28 16 01 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. 7 �h wrightsofr Right-SufteO Universal 2017 17.0.14 RSU08101 2017-Apr-10 1 Page 5 ...k CalcMDocumentslWYM4E-THE WINDSOR-REVISED.mp Colo =MJ8 Front Door faces: N +� wrightsoft, RighW@ Worksheet Job: Entire House Date: QUICK 6LCS, INC. By. 317 ST. LUCIE LM, FT. PIERCE, FL 34946 Phone: 772-466-6799 F. 772-466-6796 Email QUICKCALCStdAOL.COM 1 Room name FOYER BEDROOM wall 9.0 It 14.0 ft 3 Room height 8.0 It heat/cool 8.0 It hwy000l 4 Room dimensions 1.0 x 920 ft 13.0 x 13.0 ft 5 Room area 92o It. 169.0 ft. Ty Construction U-value Or HTiut Area (119 Load Area number (Btulvft;`F) (Btuhlft� or perimeter (ft) (Btuh) or perimeter (ft) (Btl�uh) _ Heat Cool Gross WP/S Heat Cool Gmss WP/S Heat Cool 6 13AAccs 0.143 no 4.00 265 0 0 0 0 IN 88 351 223 1Ac1om "- : -1.270 ne .. 35.56 70.43 0. 0 0 0 0 0. 0 . 0 QActom < '1Actom -1.270 ne. 35.56 - 70.43 , 0 0 , - 0 '0 - -.0 0 0 1 1. 0 ' ; 1.270 no '3556 .45.24' 0 �, 0 0 0 - 16 0, , 581 • 739 11 W, �--D 11DO 0.143 se 400 255 64 41 165 105 0 0 0 0 Vr/13A+tacs 11D0 t... •�. 0.390 '.C-0.143 se. sw 1092 -0.00 11,31 ,,_.255 23 - ..8.. 23 -- 8.. 248 --.: 32--20- 257 0 -": 0 0 _ 0 4A5-tan �. 0.770 , sw 2156 . z7.63 - - 0 0- .. 0 .. ' 0 ...8: -. .0 8':. .0 .,• 32 0 y20 ; 0 13A-4ocs 0.143 nw 4.00 255 0 0 0 0 , 0 0 0 0 1Aclom 1.270 mw 35.56 45.24 0 0 0 0 0 0 0 0 4A5-2crnd 0.770 nw 21.56 36.90 0 0 0 0 0 0 0 0 P ° :; ,;12C-Gsw.- :: - 0.091 : ' Z55 ` 1:28 '=88 88 . 224 113 104' -104 ".. 265 1s133 C 16AJ0md 0.032 - -0.90 Z32 92 92 82 213 169 169 151 392 F. : ' 22A tpl ` D.989 - 27.69 0.00 ' 92 9 249 0 169 14 : 388 - - -..0 6 c)AED excursion. -25 -52 Envelope losslgain 1002 684 1768 1456 12 a) Infiltration 162 46 252 71 b) Room ventlation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Applianoeslother 0 0 Subtotal Qines 6 to 13) 1163 730 2020 1527 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 193 8 _ 2020 1527 75 Duct loads34Yo 53q 390 8 36 34%a 537 on 808 Total mom load 1553 1116 2697 2335 Air required (cfm) 73 48 127 100 1A ' wrightsof!- Right -Suite® Universal 2017 17.0.14 RSU08101 ... k CalcslDocumentslWYMJE-THEWIW)SOR-REVISEO.mp Calc=MJ8 Front Dcorfaces: 2017-Apr-10 17:19:28 Page 6 - wrightsoft® Duct System Summary Dab: Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34948 Phone: 772466-6799Fan 772466:6796 Email OUICKCALCS AOL.COM For. WYNNE DEVELOPMENT THE WINDSOR, FT. PIERCE, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.273 in/100ft 1160 cfm Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.273 in/100ft 1160 cfm 183 ft Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diann (In) H x W (n) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 586 28 16 0.372 4.0 OxO VIFx 19.5 115.0 st1 BEDROOM c 2730 101 117 0.384 7.0 OxO VIFx 15.0 115.0 st1 BEDROOM h 2697 127 100 0.353' 6.0 0x0 VIFx 26.8 115.0 st1 DINING/GREAT ROOM C 3411 129 147 0.292 TO Ox0 VIFx 36.5 135.0 st2 DINING/GREATROOM-s C 3411 129 147 0.371 7.0 OxO VIFx 19.9 115.0 SH DINING/GREAT ROOM-C C 3411 129 147 0.278 7.0 OxO VIFx 44.9 135.0 st2 FOYER h 1553 73 48 0.490 4.0 Ox0 VIFx 7.0 95.0 KITCHEN c 2875 88 124 0.366 6.0 0x0 VIFx 21.8 115.0 st1 LAUDRY C 145 2 6 0.371 4.0 OxO VIFx 19.9 115.0 st1 M. BATH h 1091 51 50 0.282 6.0 OxO VIFx 42.3 135.0 st2 MASTER BEDROOM h 3190 150 124 0.273 6.0 0x0 VIFx 48.4 135.0 st2 MASTER BEDROOM -A h 3190 150 124 0.284 6.0 OxO VIFx 40.9 135.0 st2 wic C 216 4 9 0.292 4.0 OX10 VIFx 36.0 135.0 st2 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (Cfm) (cfm) FR (fpm) (in) (In) Material Trunk st2 Peak AVF 612 602 0.273 780 12.0 0 x 0 VinIRx st1 S11 Peak AVF 1087 1112 0.273 796 16.0 0 x 0 VinlFlx Wrl htsoft' ton-Apr-1017:19:29 �� 9 Right-SuiteO Universal 2017 17.0.14 RSU08101 Page 1 ...k CalcslDocuments%WYNNE-THE WINDSOR-REVISED.mp Calc =MJ8 Front Doorfaces: N Name Grille Size (in) Htg (cfm) Clg (cfm) TEL M Design FIR Veloc (fpm) Diam (n) H x W (in) Stud/joist Opening (in) Duct. Math Trunk rb1 Ox0 1160 1160 0 0 0 0 Ox 0 VIFx t }Jµ-. Wrl htsoft 2017-Apr-i017ag:29 Ai " f 9 RightSuke®Univemal 2017 17.0.14 RSU08101 Page 2 ... k Calcs\Documents\WYNNE-THEWINDSOR-REVISED.mp Calc=MJB Front Dcorfaces: N