Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017• r' FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT SCANNED Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Owner. �``�^ �� S Permit Number: Jurisdiction: Y ®ya St St Lucie County Design Location: FL, Fo .Pierce County:. _St. Lucie (Florida Climate. Zone_ 2)_ _ 1. New construction or existing New (From Plans) 9. Wall Types (1432.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1224.00 ft' b. Frame - Wood, Adjacent R=11.0 208.00 ft' 3. Number of units, if multiple family 1 c. N/A R= fF 4. Number of Bedrooms 3 d. N/A R= 82 5. Is this a worst case? Yes 10. Ceiling Types (1753.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1753.00 ft' 6. Conditioned floor area above grade 1753 b. N/A R= ft' Conditioned floor area below grade (W) 0 c. N/A R= ft 11. Ducts R ft' 7. Windows(151.4 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 250 a. U-Factor: Sgl, U=0.63 111.36 ft' SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.65 40.00 ft' 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 34.8 SEER:15.00 c. U-Factor. N/A ft' SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft' a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 2.850 ft. Area Weighted Average SHGC: 0.239 14. Hot water systems 8. Floor Types (1753.0 sqft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ft' b. Conservation features EF: 0.970 b. N/A R= ft' None c. N/A R= ft' 15. Credits Pstat Glass/Floor Area: 0.086 Total Proposed Modified Loads: 52.93 PASS Total Baseline Loads: 53.85 1 hereby certify that the plans and specifications covered by Review of the plans and sTAP� this calculation are in compliance with the Florida Energy specifications covered by this OQ48E �S , O Code. calculation indicates compliance r g`v i,, "' _ ,. AzBi&Before with the Florida Energy Code. �. PREPA D Y: construction is completed I t O DATE: this building will be inspected for compliance with Section 553.908 O - X I hereby certify that this building, as designed, is in compliance Florida Statutes. !), with the Florida Energy Code. OWNE C Tom}- � BUILDING OFFICIAL: C0 WE �O DATE: ` �`` \ I DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 11/1912018 2:39 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT r PROJECT Title: WYNNE THE WINDSOR IMP Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1753 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 225 Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, -New/Existing: New (From Plans) - Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1753 14024 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 MASTER BEDROO 224 1792 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 MASTER BATH 56 448 No 0 1 Yes Yes Yes 4 M. BATH 61 488 No 0 1 Yes Yes Yes 5 LAUDRY 36 288 No 0 1 No Yes Yes 6 BEDROOM 2 180 1440 No 0 1 1 Yes Yes Yes 7 DINING/GREAT R 588 4704 No 2 1 Yes Yes Yes 8 KITCHEN 209 1672 Yes 0 1 Yes Yes Yes 9 BATH 50 400 No 0 1 Yes Yes Yes 10 HALL 25 200 No 0 1 No Yes Yes 11 FOYER 92 736 No 0 1 Yes Yes Yes 12 BEDROOM 3 169 1352 No 0 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio MASTER BEDRO 37 It 0 224 ft' ____ 0 1 0 2SIab-On-Grade Edge Insulatio WIC 1 ft 0 63 ft' ____ 0 1 0 3 Slab -On -Grade Edge Insulatio MASTER BATH 8 ft 0 56 ft' ___ 0 1 0 4 Slab -On -Grade Edge Insulatio M. BATH 7 ft 0 61 ft' -- 0 1 0 5 Slab -On -Grade Edge Insulatio LAUDRY 1 ft 0 36 ft' 0 1 0 11/19/2018 2:39 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 6 Slab -On -Grade Edge Insulatio BEDROOM 2 12 ft 0 180 it, ---- 0 1 0 7 Slab -On -Grade Edge Insulatio DINING/GREAT 50 ft 0 588 fF ---- 0 1 0 8 Slab -On -Grade Edge Insulatio KITCHEN lift 0 209 ft' ---- 0 1 0 9 Slab -On -Grade Edge Insulatio BATH 5 ft 0 50 ft' ---- 0 1 0 10Slab-On-Grade Edge Insulatio HALL t It 0 25 ft' ---- 0 1 0 11Slab-On-Grade Edge Insulatio FOYER 9 it 0 92 ft' ---- 0 1 0 12SIab-On-Grade Edge Insulatio BEDROOM 3 14 it 0 169 ft' ---- 0 1 0 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1847 ft' 292 ft' Light 0.6 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1753 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) MASTER BEDRO 30 Blown 224 ft' 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft' 0.1 Wood 3 Under Attic (Vented) MASTER BATH 30 Blown 56 ft' 0.1 Wood 4 Under Attic (Vented) M. BATH 30 Blown 61 ft' 0.1 Wood 5 Under Attic (Vented) LAUDRY 30 Blown 36 ft' 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 180 ft' 0.1 Wood 7 Under Attic (Vented) DINING/GREAT 30 Blown 588 ft' 0.1 Wood 8 Under Attic (Vented) KITCHEN 30 Blown 209 ft' 0.1 Wood 9 Under Attic (Vented) BATH 30 Blown 50 ft' 0.1 Wood 10 Under Attic (Vented) HALL 30 Blown 25 ft' 0.1 Wood 11 Under Attic (Vented) FOYER 30 Blown 92 ft' 0.1 Wood 12 Under Attic (Vented) BEDROOM 3 30 Blown 169 ft' 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Belo SpaceAre,gnr w 1 NE=>W Exterior Concrete Block - Ext InSNASTER BE 4.1 16 0 8 0 128.0 ft' 0 0 0.4 0 2 SW=>E Exterior Concrete Block - Ext InAMSTER BE 4.1 7 0 8 0 56.0 ft' 0 0 0.4 0 3 NW=>S Exterior Concrete Block - Ext InWASTER BE 4.1 14 0 8 0 112.0 ft' 0 0 0.4 0 4 NE=>W Exterior Concrete Block - Ext InWASTER BA 4.1 8 0 8 0 64.0 ft' 0 0 0.4 0 11/19/2018 2:39 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 6 .FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT + WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 5 NE=>W Exterior Concrete Block - Ext InsuM. BATH 4.1 7 0 8 0 56.0 ft' 0 0 0.4 0 6 NE=>W Exterior Concrete Block - Ext InRffDROOM 2 4.1 12 0 8 0 96.0 ft' 0 0 0.4 0 7 SW=>E Exterior Concrete Block- Ext InQdNINGIGRE 4.1 30 0 8 0 240.0 ft' 0 0 0.4 0 8 NW=>S Exterior Concrete Block - Ext InUNING/GRE 4.1 20 0 8 0 160.0 ft' 0 0 0.4 0 9 SW=>E Exterior Concrete Block - Ext InsulUTCHEN 4.1 11 0 8 0 88.0 ft' 0 0 0.4 0 10 NE=>W Exterior Concrete Block - Extlnsul BATH 4.1 5 0 8 0 40.0 ft' 0 0 0.4 0 11 SE=>N Exterior Concrete Block - Ext Insul FOYER 4.1 8 0 8 0 64.0 ft' 0 0 0.4 0 12 SW=>E Exterior Concrete Block - Ext Insul FOYER 4.1 1 0 8 0 8.0 ft' 0 0 0.4 0 13 NE=>W Exterior Concrete Block - Ext InSffDROOM 3 4.1 13 0 8 0 104.0 ft' 0 0 0.4 0 14 SW=>E Exterior Concrete Block - Ext In!8EDROOM 3 4.1 1 0 8 0 8.0 ft' 0 0 0.4 0 15 N=>SW Garage Frame - Wood BEDROOM 3 11 26 8 208.0 ft' 0.23 0.4 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SE=>N Insulated FOYER None .39 3 3 6 8 21.7 ft' WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>S 3 Metal Low-E Single Yes 0.63 0.25 N 32.4 ft' 1 ft 0 in 1 It 4 in Drapes/blinds Exterior 5 2 NE=>W 5 Metal Low-E Single Yes 0.63 0.25 N 6.9 ft' 1 ft 0 in 1 ft 4 in None None 3 NE=>W 6 Metal Low-E Single Yes 0.63 0.25 N 16.2 ft' 1 ft 0 in 1 ft 4 in None None 4 SW=>E 7 Metal Low-E Single Yes 0.63 0.25 N 39.8 ft' 1 ft 0 in 1 ft 4 in None None 5 NW=>S 8 Metal Low-E Single Yes 0.65 0.21 N 40.0 ft' 8 ft 0 in 1 ft 4 in None None 6 NE=>W 13 Metal Low-E Single Yes 0.63 0.25 N 16.2 ft' 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 806 ft' 806 ft' 26 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1636.1 89.82 168.92 .2578 7 11/19/2018 2:39 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Duds 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr dm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None fN DUCTS -- Supply — — Return — Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 250 ft' Attic 75 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programabl[e Thermosta((t:��Y Ceil]ling Fans: Heating [X] Jan [X] Feb Mar r Apr € ay [ ] fX� [X] Jun [) Jul 1 rX� [) Aug f (X) Sep [[[ ] L J Oct NovIr)C')Novr Dec Venting [[ ]I Jan II 11 Feb X Mar [ May 11 l[[ ]]1 Jun [) Jul [) Aug ]] Sep lxl [X] Nov [ Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 11/19/2018 2:39 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 6 ,FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT MASS • Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft' 0 ft 0.3 MASTER BEDROO Default(8 lbs/sq.ft. ft' ft 0.3 WIC Default(8 Ibs/sq.ft. ft' ft 0.3 MASTER BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 M. BATH Default(8 lbs/sq.ft. ft2 ft 0.3 LAUDRY Default(8 lb_s/sq.ft.. ft' ft. 0.3. BEDROOM Default(8 lbs/sq.ft. ft' ft 0.3 DINING/GREAT R Default(8 lbs/sq.ft. ft' ft 0.3 KITCHEN Default(81bs/sq.ft. ft' ft 0.3 BATH Default(8 lbs/sq.ft. ft' ft 0.3 HALL Default(8 lbs/sq.ft. ft' ft 0.3 FOYER Default(8 Ibs/s .ft. ft2 ft 0.3 BEDROOM 3 Name: Test Rater Signature:] 0=2��'-K(2p Rating Compant: Test Rater Date: l I—tri 11/19/2018 2:39 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 6 of 6 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y Owner: Jurisdiction: w Design Location: FL, Fort Pierce c=i COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in an dropped ceiling/soffit Y /soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall,be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light factures installed in the building thermal envelope Recessed light factures installed in the building shall be sealed to the drywall. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall Showeritub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids a. In addition, inspectwn of log walls shall be in accordance with the provisions of ]CC-400. 11/19/2018 2:40 PM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 34.8 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER c) Ground/water source SEERICOP 6. Conditioned floor area (sq. ft.) 6. 1753 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.635 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.239 c) Area 7c. 151.4 8. Skylights a) U-factor:(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 9a. 0.0 9b. 9c. 10A1. 10A2. 4.1 14. Heating system: Capacity 34.8 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF c) Electric resistance COP d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE f) Other 16. Water heating system a) Electric resistance EF 0.97 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF_ f) Heat recovery unit HeatRec% g) Other 10B1. 11.0 10B2. 16. HVAC credits claimed (Performance Method) a) Ceiling fans 1la. 30.0 b) Cross ventilation No 11b. c) Whole house fan No 11c. d) Multizone cooling credit 11d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Cade, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on install a de compliant features. Builder Signature: Date: Address of New Home: THE WINDSOR Q-CA\�'e City/FL Zip: FT. PIERCE. FL 11/19/2018 2:39:55 PM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 - weightsoft® Project Summary Entire House `QUICK CALCS, INC. Job: Date: By: For. WYNNE DEVELOPMENT SCANNED THE WINDSOR, Fr. PIERCE, FL BY Notes: -;�A `�� �— `Ovs. St. Lucie County Weather. Winter Design Conditions Outside db Inside db Design TD Fort Pierce, FL, US Summer Design Conditions' 42 OF Outside db 70 OF Inside db 28 OF Design TD Daily range Relative humidity Moisture,difference Heating Summary Structure 18467 Btuh Ducts 6190 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 24657 Btuh Infiltration Method Construction quality Fireplaces Simplified Average Area ftz He 1753 Coo753 Volume(ft3) 14741 14741 Air changes/hour 0.38 0.20 Equiv. AVF (cfm) 93 49 Heating Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Model 25HBC536A*030 AHRI ref 7914585 Efficiency Heating input Heating output Temperature rise Actualair flow Air flow factor Static pressure Space thermostat Capacity balance point = 34 OF Backup: 8.5 HSPF 34600 Btuh @ 47*F 27 OF 1160 cfm . 0.047 cfm/Btuh 0.50 in H2O Input = 7 kW, Output = 23009 Btuh, 100 AFUE 90 OF 75 OF 1L OF 50 % 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 17655 Btuh Ducts 9340 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/svinpp menus! 0.95 Equipmenfsensibleload 25645 Btuh Latent Cooling Equipment Load Sizing Structure 2453 Btuh Ducts 2554 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 5007 Btuh Equipment total load 30652 Btuh Req. total capacity at 0.70 SHR 3.1 ton Cooling Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Cond 25HBC536A*030 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 12.0 EER, 15 SEER Sensible cooling 24360 Btuh Latent cooling 10440 Btuh Total cooling 34800 Btuh Actual air flow 1160 cfm Air flow factor 0.043 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.84 Calculations approved byACCA to meet all requirements of Manual J 8th Ed ACCA- wrightsofY RightSuite® Universal 2017 17.0.14 RSU08101 2017-Apr-1017:19:28 ... k CaIcslDocumentslWYMJE-TFfl= WINDSOR-REVISED.rup Calc = MJB Frant Daor faces: N - Page 1 +p- wrightsoft, Right-J& Work'sheet Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-4666799 Fax 772-4666796 Email: Ol1ICKCALCS@IOL.COM Job: Date: By: 1 Room name Entire House MASTER BEDROOM 2 Exposed wall 153.0 ft 45.0 ft 3 Room height 8.4 ft d 8.0 ft heat/cool 4 Room dimensions 1.0 x 260.0 It 5 Room area 1753.0 ft' 280.0 fl' Ty Construction U-value Or HTM A rea Load Anse number I (Btuh/ft;°F) (Btuwft) or perimeter Ill) (Btuh) or perimeter (ft) (Stub) Heat I Cool Gross WP/S Heat Cool Gross WP1S Heat Cool 6 13A4ccs 0143 no 400 265 488 448 1795 1141 192, 192 769 489 1Aclorp ,1270 no, $556 . 70.43 7 0 =: 247 - 488 0 0, ;0 0 1270'no �_35.55 - �' 70.43 . 161 0 _- 581 :.1151 0" 0 ,: 0 'ts0 4Aclorn 1.270 ne. - '35.56 45.24 16' 6 . 581 ' _ 739 0, 0 : .0 . :;'�0 11 W �--D 13A-4= 0.143 se 4.00 255 64 41 165 105 0 0 0 0 11D0 0390 se 1092 11.31 23 23 248 257 0 0 D 0 ,13AA66$: .., _:b 143 sw :. '400 ,-255 437 "::. ,396 1584 ., a..1007 .. -,56 56=- ` 224 143 '-0.770 sw 2156 . 7 .-053 41 45 893 ? .. 1140 :' 0 10 -. _0 '.o 13A-4= 0.143 nw 4.00 255 290 217 867 551 112 79 318 202 I--G 1Actom 1.270 nw 35.56. 4524 33 0 1162 1478 33 0 1162 1478 4A5-2omd 0770 nw 21.56 36.90 41 0 880 1505 0 0 0 0 P.:_....;, :12C-03iva', - . ....:0.091 - ,`-' 2.55 - 1:28 , . .308 :. -,:308 . . _ 784 . ," 395 '. :. '0 . '+0 , , ' , 0 ' " „0. C 16A',Arnd 0.032 - 0.90 2.32 1753 1753 1671 4067 280 280 251 650 'F'., .: 22A-tpl`. ,. -0.999 - 27.69 .. .0.00 .. 1753 -153 4237 '0 290 .. 45 _ ... ,1246 ,...: ."--''0 6 c)AED mmlon 1360 600 Envelope loss/gain 15594 15385 3970 3561 12 a) Infiltration 2873 810 _ 809 228 . b) Room ventilaffon 0 0 0 0 13 Intemal gains: Occupants Q 230 2 460 0 0 Appliances/other 1000 0 Subtotal Qines 6 to 13) 18467 17655 4779 3789 Less eMemal load 0 01 '0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal law 17655 47/9 3789 15 Duct loads 34% 53% 6190 9340 34% 53% 1602 2005 Total room load 24657 26M 6380 5794 Air required(cfm) 1 1160 1160 300 249 wrightsoftr RlghtSuite® Unhersal 201717.0.14 RSU08101 ...k Celcs\Documents\WYNNE-THE WINDSOR-REVISED.mp Dole =MJB Front Door faces: N 2017-Apr40 17:19:28 Page 1 wrightsoft Right-M Worksheet Job: Entire House Date: ' QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: OUICKCALCS AOL.COM 1 Room name WIC M. BATH 2 F)osed wall 0 It 7.0 It 3 Room height 8.0 It heat/cool 8.0 ft heat/cool 4 Room dimensions 7.0 x 9.0 ft 1.0 x 61.0 ft 5 Room area 63.0 ft2 1 61.0 ft2 TY Constmctim U-value Or HTM Area Am Load number (SIuh1ft-F) (6tuwft2) or perimeter (ft) (Etuh) o perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross I WP/S Heat Cool 6 13AAccs 0143 ne 400 255 0 0 0 0 56 49 196 125 1Aotmt 1270 ne 3556 56 -,70.43 : 70A3 '" 0 ? 0 _ o -_; 0 7' .. 0 _ 247 0 .1Ac1om _1270 '1.270 ne:35 0 0 .':0 " 0 0 0 .1Ao1om,. .,. ne•'r 35.5645:24 :. 0 ,Oa 0! '0 0 0 c-' .: �0 11 W- 13A4acs 0.143 se 4.00 255 0 0 . 0 0 0 0- :0 0 0 —D .. - 11DO 13A-0acs _ 0390 ;0143 se sw 1092 ,.----400 11.31 • .c2,65 0 :0 0 d. 0",- 0 0 .; 0 0 0: 0 0 0 0 ''.::0 4A -20M .: - :0.770 sw -2156 :27.53 0 0 _ 0 ..0 - 0 -... ." 0' 0 0 _ •.0 Vpl 13A-0acs 0.143 rrvi 4.00 255 0 0 0 0 0 .0'.:'_ 0 0 0 1Ac1om 1.270 nw 35.56 45.24 0 0 0 0 0 0- 0 0 IF---GG 4AS2and - 0.770 nw 21.56 36.90 0 0 0 0 0 0 0 0 P ,'..: '.12C-0sw.` .; '0.091 , :- - --'255 '- 1:28 '0 - .:0 ` -0 0 0 . 0.... <0 : •:: .,o C 'F' • 16A-30md - 0.032 - 0.90 232 63 63 56 146 _ 61 61 55 142 22htpl : . - 0:989 -- - 27.69 - 0.00 . ,. 63 :0 - -0 -0 61 7 -194 * " 0 6 c)AED elcrasion -5 -26 Envelope loss/gain 1 56 141 6921 729 12 a) hIltratim 0 0 126 35 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants Q 230 0 0 0 0 Applianceslother 0 0 Subtotal Qirtes 6to 13) 56 141 817 764 Less e#anslload 0 0 0 0 Less transfer D 0 0 0 Redistribution 0 0 0 0 14 Subtotal 56 141 817 764 15 Duct loads 34% 531/6 19 75 34% 531/6 274 404 Total room load 1 75 216 1091 1168 Air required (cfm) 4 9 51 SD -Fp- wrightsoft• RlghtSuite® Universal 201717.0.14 RSU08101 ... k CalcslDocuments%WYNNE-THEWINDSOR-REVISEO.mp Calc=MJ8 Front Doorfaces: 2017-Apr-10 17:19:28 Page 2 wrightsoft' Right-J® Worksheet Job: Entire House Date: QUICK CALCS, INC: By: 317 ST. LUCIE I.R. FT. PIERCE, FL 34946 Phone: 772-46"799 Fax 772-466-6796 Emil: OUICKCALCWOL.COM 1 Room name LAUDRY BEDROOM 2 - Dposed wall 0 ft 120 ft 3 Room height 8.0 ft heat/cool 8.0 ft heaticool 4 Room dimensions 6.0 x 6.0 ft 15.0 x 120 ft 5 Room area 36.0 ft- 180.0 ft2 Ty Coristmctim U-value Or HTM Area (ft') Load Area Load number (BtuWft-F) (Btuwft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 13A-0acs 0 143 ne 400 255 0 0 0 0 96 80 319 203 1Ac1om .. .1270 ne .i3556 . 70.43 0 - 0 `1Actom -_ _d 270 ne. 3556 :70.43' 0 0 0 , . 0 ".16 0 SBi '116f. . ,tActom ,1.270 ne 35.56 . -. 45.24 -- 0 0 : - 0 0 .. 0 - .. 0 .. 0 11 VL-D 13A4ocs 0.143 se 4.D0 2.55 0 0 0 0 0 0 ;. 0 0 1100 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 Vr/ LG: 13Adacs --_� -0143 sw - , 400 .: 255 0 0 ,. 0 . 0 0 -,0 -- - - 0 4AS2orn,`- ''0770.sw� •.21.56 ...27.53; 0" "0 0 . 0 ..=0 `>0 W 13A-0ocs 0.143 nos 4.00 2.55 0 0 0 .0 0 0 .0-•'0 0 0 0 I--G 1Ac1am 1.270 rnv 35.56 45.24 0 0 0 0 0 0 0 0 �� _ 4AS2omd -... 0.770 ' nw 21.58 36.90 0 0 0 0 0 0 0 0 712C-)sw :0.091 `:-'. -255-' 128 0 .0- 0, 0.' .. p.. p.-. :.f0. C '. 16Atpi 0.032 - 0.90 232 36 36 32 84 180 160 161 _,0 418 F ••"22Adpl.[ , :' .0.989 -" 27.69 = ..0.00 36 0 0' 0 180' '.12 :: 332 e::.'t.:'., -'0 �y. 6 c)AED enwrsim -3 ,60 Emelope loss7gain 32 81 1394 1711 12 a) Infiltration 0 0 216 61 b) Room ventilation 0 0 0 0 13 Internal gains: occupants Q 23D 0 0 0 0 Appliances/other 0 0 Subtotal Vines 6 to 13) 32 81 1609 1772 Less edenel load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 14 6 14 14 Sulrtot81 38 95 1615 1786 15 Duct loads U04 53% 13 50 34% 53% 541 945 Total room Iwd 51 145 2156 2730 Air required (cfmj 2 6 101 117 Calculations approved byACCA to meet all requirements of Manual J Oth Ed wrightsoft- RlghtSUlte® Universa1201717.0.14 RSU08101 2017-Apr-1017:19:28 A... k CaleslDocuments\WYNNE-THEWINDSOR-REVISED.mp Cale=MJ8 Front Door6ces: N Page f�lr wrightsoft Right-d®' Worksheet Job: Entire House Date: QUICK CALCS, INC. By 317 ST. LUCIE LPL, FT. PIERCE, FL 34946 Phone: 772-06"799 Fax 772466-6796 Email: QUICKCALCS@1OLCOM mDINING/GREAT ROOM KITCHEN wall 50.0 ft 11.0 ft ight TRmm 8.9 ft heat/cool 8.9 ft heaVcool mensions 1.0 x 588.0 ft 19.0 x 11.0 ft a 588.0 ft2 209.0 112 Ty Constmction U-value Or HTM Area Lo Area number (atuIV1lMF) (BtUlVft2) cr perimeter (ft) (Btuh) perimeter (ft) (Btuh) _ Heat Cool Gnus WP/S Heat Cool Gnus WP/S Heat Cool 6134.4ocs 0.143 no 4.00 2.55 0 0 0 0 0 0 0 -0 1Aclom, - ,1270 ins,' •35.66 .70.43 0 -0 0 0 0 0. 0 --'0 ..1Ac1om ' `1270 no 3556 5 70.43 .. -0 0 . •0. 0 - ,.'0. .0- 0 p :7Acl= '-1:270 no " 95.56 45:24 0 0 - 0 ' 0 - 0 - 0 0 = -0 11 Vy �--D 13A-0acs 0.143 se 4.00 255 0 0 0 0 0 0 . 0 0 11DO _ 0390 se -sw.; 1092 11.31 0 0 0 0 0 0 0 0 �4AS2om -0143 - 400 " :,. 255 ' 267 _. 226 ' . --:. 903 ` . ,. 574 ..98' _ 98: 392 :: •249 " 0.770 esw .'21.56 . 27.53 41 22 . - 893 - 1140 -._ 0 ;A , ..p :'-0 13A-4ms' 0.143 nw 4.00 2.55 178 137 549 349 0 0 0 0 1Aclom 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 �-G "'.: 4A5-2and '12C-0swi ".. 0.770 nw 21.56 36.90 41 0 880 1505 0 0 0 0 P , -'0.091 .-. ..2.55 ' 128 a 0 0 . .0 ..: ..,116 . .116 . '.. 295 , ,>-"-' 148 C 16A30md 0.032 - 0.90 232 588 588 527 1364 2D9 209 187 485 F''.- ., 22AApl' 0.989 - -'- 27.69 , . 0.00 -. ..558 50 1385 . 0' : 209 . 11 " 305 -:.10 6 c)AEO excursion low .64 Envelope loss/gain 5136 5937 1179 818 12 a) hifinration 10D0 282 220 62 b) Room ventilation 0 0 0 0 13 hemal gains: Occupants @ 230 2 460 0 0 Appliances/other 0 _ 1000 Subtotal (lines 6 to 13) 6136 6679 1399 1860 Less eAv load 0 0 0 0 Less transfer 0 0 0 0 Redlstsbution 6 14 0 0 14 Subtotal 6142 6693 1399 1880 15 Duct loads 34% 530% 20% 3541 34% 53% 469 995 Total room load 8200 10234 1897 2875 Airrequired(clim) 386 440 - 88 124 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. wrightsoft• Rig2017-Apr-1017:19:28 G`A THE WINDS R-REVISED.m 7.0 of RSU08101 Page 4 ...k CateslDocuments\WYNNE-THE WINDSOR-REVISED.rup Cale=MJ8 Front Door faces: N -F wrightsoft° RighW@ Worksheet Entire House QUICK CALCS, INC. 317 ST LUCIE I-M, FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-46"796 Email: QUICKCALCS(SgOLCOM Job: Date: By: 1 Room name BATH HALL 2 Exposed wail 5.0 ft 0 ft 3 Room height 8.0 it heat/cool 8.0 ft heal/cool 4 Room dimensions 10.0 x 5.0 it 5.0 x SO ft 5 m Rooarea 0 ft 25.0 fti TY Construction U-value Or HTM Area Arm(ftz) Load number (BtufJft °F) (Btuhlft°) or perimeter (ft) (&uh) or(ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross WPIS Heat Cool 6 13A-0ocs 0.143 ne .400 255 40 40 160 102 0 0 0 0 itAclom 1.270 ne ' ,35.56 .70.43 0 .0 - - 0 - ' 0 -. 0 0 .'. 70 ti1Aclom , `.1Ao16nn ..1',270 ne - 3556 ..70.43 -.0�• o _ -... 0. .0 _' 0 p r. 0' 0 ;': 0 - fZ70 .ne, t95.56 -,45.24 0. 0. 0 - 0 0 0.... ':0 11 W 13A-0ocs 0.143 se 4.00 255 0 0 0 0 0 0 :0 0 .:., 0 --D W ..x� 11D0 '13A-0ocs 0.390 0.143 se sw _ 10.92 -t400 11.31 .255 0 0 0 0'-. 0 - 0 0 • 0 -.. .. 0 0 0 L==G 'dAS2om - :':0.770-,sw _-2156 _-zz53 , p'• . -0. -. .=0, -0 p' 0 `. o 0 0 :t. one 0 b V}I 13A-0acs 0.143 nw 4 DO 2.55 0 0 0 0 0 .O 0 0 0 II ---.GO 1Aclam 1.270 my 35.56 45.24 0 0 0 0 0 0 0 0 .�: 4A5-2omd 0.770 nw 21.56 36.90 0 0 0 0 0 0 0 0 P..° 12C-OsW' - 0.091 - ."Z65 '_ -1:28 0 -.0 0- 0' .."0. "0 : 0. .. ..0 C _. 16A30md 0.032 - 0.90 232 50 50 45 116 25 25 22 58 F r 22A4pd- _ 0.989 - 'Z7.69 -- 0.00: 60 5 138 . 0 25. - '0 0 10 6 c)AED elcursdcn -8 -2 Envelope loss/gain 343 210 22 56 12 a) Infiftration 90 25 0 0 b) Room ventilation 0 0 0 0 13 Internet gains: Occupants @ 230 0 0 0 0 Applianceslother 0 0 Subtotal Oines 6 to 13) 433 235 22 f6 Less coderrel load 0 0 0 0 Less transfer 0 0 0 0 Red4stribution 6 14 -22 56 14 Subtotal 439 249 0 0 15 Duct loads 34% 53% 147 132 34% 53% 0 0 Toted room load 586 381 0 0 Air required (cfm) 28 16 0 0 Amik fpF- wrightsoR- RlghtSuite® Universal 201717.0.14 RSUD8101 ... k Calcs\Documents\WYNVE-THEWINDSOR-RENSED.mp Calc=MJB Front Doorfeces: 2017-Apr-10 17:19:28 Page 5 wrightsoft; Right-J®' Worksheet Job: Entire House Date; QUICK CALCS, INC. B9- 317 ST LUCIE LU, FT. PIERCE, FL 34946 Phone: 772-46"799 Fa¢ 772-466-6796 Email: OUICKCALCSaAOLCOM 1 Room name FOYER BEDROOM 3 2 FVosed wall 9.0 ft 14.0 ft 3 Room height 8.0 It heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 920 ft 13.0 x 13.0 ft 5 Room area 920 W 169.0 ft2 Ty Construction U-value Or HTM Area Area Load number (BtulVft-F) (Btuh/fP) or perimeter (ft) (Bt�uh) o perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gnus WP/S Heat Cool 6 13A ces - 0143 no 400 2.55 0 0. 0 0 104 88 351 223 x [1Ao1om - .270 1 no ,.' 3558 70.43 0. 0 - D 0 0 ` 0 0 0 1Aa1om -; 1270 ne :"3556 70.43, 0 O. 0 '0 '0: 0:' . 0 1:0 11 ly aAclom . 13A4acs - 1.270 0.143 •ne se 35.56 4.00 .� 46.N 255 0 64 . 0 41 . - 0 '165 : 0 16 ` 0' 581 .. :739 -D 11D0 13A-0ocs ., 0.390 ;-0.143 se sw 1092 ,': - A00 11.31 '; - 255 23 . B 23 ,. a 248 ". 32 105 257 L * 20 0 0 = 8 g 0 8 0 0 - 0 0 I-=G 4AM . 0.77o sw -i156 _ ` z7s3 0 0 , :. o : : � o . .. 0 . ' . 0 .. 32 . ,-. ' o :20 "o V(/ 13A4ocs 0.143 nw 4.00 255 0 0 0 0 0 0 0 0 1A-clom 1.270 my 35.55 45.24 0 0 0 0 0 0 0 0 4A5-2omd 0.770 nw 21.56 36.90 0 0 0 0 0 0 0 0 P° .:12C-Oswc. .` .. 0.091 '2.5s `.1:28 . .,!)8 .88 •'224. 113 .104 :. 1.104 " ' 265 ` ., 13 C " 16A-30md 0.032 - 0.90 232 92 92 82 213 169 169 151 392 f - 22AAph' 0.989 ; -' 2769 . 0.00 92 9 - 249 .0 -169- -14 .; -388 6 c)AH excursion -25 -52 Envelope lass/gain 1002 684 1768 1456 12 a) IMnration 162 46 252 71 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants Q 230 0 0 0 0 Appliances/other 0 0 Subtotal alnes 6 to 13) 1163 730 2020 1527 Less e#em al load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1163 730 2020 16V 15 Duct loads 34% 53% 390 386 347. 539% 677 808 Total room load 1653 1116 2697 2335 Air required (cfm) 73 48 127 100 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed 41- wrightsoft- 2017-Apr-1017:19:28 lA _ RlghtSulte® Universal 201717.0.14 RSU08101 Page 6 ...k CalcslDocumentslWYNNE-THE WINDSOR-REVISED.rup Cale =MJ6 Front Door faces: N g Duct System Summa Job: wlrightsoft y Date: ghfire abuse By; QUICK CALCS, INC. 317 Sr. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-4665796 For. WYNNE DEVELOPMENT THE WINDSOR, FT. PIERCE, FL External static pressure Pressure losses Available Static pressure Supply/ return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.273 in/100ft 1160 cfm Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.273 in/100ft 1160 cfm 183 ft Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Mat] Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 586 28 16 0.372 4.0 OxO VIFx 19.5 115.0 st1 BEDROOM 0 2730 101 117 0.384 7.0 OxO VIFx 15.0- 115.0 SO BEDROOM 3 h 2697 127 100 0.353 6.0 OxO VIFx 26.8 115.0 st1 DINING/GREATROOM C 3411 129 147 0.292 7.0 0x0 VIFx 36.5 135.0 st2 DINING/GREATROOM-B C 3411 129 147 0.371 7.0 OxO VIFx 19.9 115.0 SO DININGIGREAT ROOM-C C 3411 129 147 0.278 7.0 0x0 VIFx 44.9 135.0 st2 FOYER h 1553 73 48 0.490 4.0 Ox0 VIFx 7.0 95.0 KITCHEN C 2875 88 124 0.366 6.0 Ox0 VIFx 21.8 115.0 SO LAUDRY c 145 2 6 0.371 4.0 OxO VIFx 19.9 115.0 st1 M.BATH h 1091 51 50 0.282 6.0 OxO VIFx 42.3 135.0 st2 MASTER BEDROOM h 3190 150 124 0.273 6.0 OxO VIFx 48.4 135.0 st2 MASTER BEDROOM -A h 3190 150 124 0.284 6.0 OxO VIFx 40.9 135.0 st2 WIC c 216 4 9 0.292 4.0 0x0 VIFx 36.0 135.0 st2 Trunk Htg Cig Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR(fpm) (in) (in) Material Trunk st2 Peak AVF 612 602 0.273 780 12.0 0 x 0 VInIFIX stl stl Peak AVF 1087 1112 0.273 796 16.0 0x 0 VinlFlx t wri hi:50ft' 2o17-Apr-10 17n9:29 9 RightSuite® Universal 201717.0.14 RSU08101 Page 1 ...k CalcsIDocumentslWY*E-THE WINDSOR-REVISED.rup Cale =MJ8 Front Door faces: N Name Grille Size (in) Htg (Cfm) Clg (Cfm) TEL (ft) [Design FIR I Veloc (fpm) I Diam Qn) I H x W (in) I Stud/Joist Opening (in) Duct. Mat[ I Trunk rb1 OxO 1160 1160 0 1 0 0 0 Ox 0 1 VIFx wrightsoft' RightSuite® Universal 2017 17.0.14 RSU08101 2017-Apt-1017:age 2 Page 2 ...k CalcslDocumentslWYNNE-iIiE WINDSOR-REVISED.rup CaIc=MJe Front Door faces; N