Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ENERGY EFFICIENCY CODE
FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method _ Project Name: WYNNETj�HE GRAND CARLTON Street: �-QCt 'Q�-,Q` !C\,�f�p Builder Name: WYNNE BUILDING COPR. Permit Office: ST. LUCIE COUNTY SCANNED City, State, Zip: FT. PIERCE, FL, �C Permit Number. By Owner. WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY Si. Lucie Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 )County 1. New construction or existing New (From Plans) 9. Wall Types (1442.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ft' e -Wood, Adjacent R=11.0 192.00 ft' 3. Number of units, if multiple family 1 0. N/A R= fN 4. Number of Bedrooms 2 d. N/A R= ft= 5. Is this a worst case? Yes 10. Ceiling Types (1446.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1446.00 ft' 6. Conditioned floor area above grade (ft2) 1446 b. WA R= ft' Conditioned floor area below grade 0 c. WA R= ft' 11. Ducts R ft' 7. Windows(141.3 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 250 a. U-Factor. Sgl, U=0.36 101.25 ft' SHGC: SHGC=0.25 b. U-Factor: SgI, U=0.65 40.00 ft' 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 34.8 SEER:15.00 c. U-Factor. N/A ft' SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor. WA ft' a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.832 ft. Area Weighted Average SHGC: 0.239 14. Hot water systems 8. Floor Types (1445.5 sqft,) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1445.50 ft' b. Conservation features EF: 0.970 b. N/A R= ft' None c. N/A R= ft' 15. Credits Pstat Glass/Floor Area: 0.098 Total Proposed Modified Loads: 47.18 PASS Total Baseline Loads: 48.09 1 hereby certify that the plans and specifications covered by Review of the plans and STglB this calculation are in compliance with the Florida Energy specifications covered by this 04TSfi y 0� Code. calculation indicates compliance with the Florida Energy Code, r► uiu("%,'2 iq?;,• , PREPAR BY' Before construction is completed r O DATE: _ this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. !,), with the Florida Energy Code. COp WE OWNER/ (QP BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH60 (R402.4.1.2). 11/8/2018 3:28 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE THE GRAND CARL Bedrooms: 2 Address Type: Street Address • Building Type: User Conditioned Area: 1446 Lot# Owner Name: WYNNE BUILDING CROP Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE BUILDING COPR. • Rotate Angle: 180 Street: Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST. LUCIE COUNTY Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL. New/Existing: New (From Plans) Comment: CLIMATE _ / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume .1 Entire House 1446 11568 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 301 2408 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M. BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0 301 ft' — 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 ft' — 0 1 0 3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0 56 ft2 ___ 0 1 0 4 Slab -On -Grade Edge Insulatio KITCHEN t ft 0 192 ft' 0 1 0 5 Slab -On -Grade Edge Insulatio BATH 5 ft 0 45 ft' 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 ft 0 203.5 ft' 0 1 0 7 Slab -On -Grade Edge Insulatio ENTRY 7 ft 0 55 ft' _ 0 1 0 11/8/2018 3:28 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio LAUNDRY Eft 0 42 ft2 __ 0 1 0 9 Slab -On -Grade Edge Insulatio GREATIDINING 46 ft 0 488 ft2 - 0 1 0 ROOF _ / Roof Gable Roof Solar SA Emitt Emift Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1524 ft2 240 ft2 Light 0.6 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1446 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Free Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 301 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic (Vented) M. BATH 30 Blown 56 ft' 0.1 Wood ' 4 Under Attic (Vented) KITCHEN 30 Blown 192 ft2 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 ft2 0.1 Wood _ 6 Under Attic (Vented) BEDROOM 2 30 Blown 204 fP 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 55 ft2 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 W 0.1 Wood 9 Under Attic (Vented) GREAT/DINING 30 Blown 488 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 NE=>SW Exterior Concrete Block- Ext Ins®EDROOM 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 2 SW=>NE Exterior Concrete Block - Ext Ins®EDROOM 4.1 28 0 8 0 224.0 ft2 0 0 0.6 0 3 NW=>SE Exterior Concrete Block - Ext Ins81EDROOM 4.1 14 0 8 0 112.0 ft2 0 0 0.6 0 4 SW=>NE Exterior Concrete Block - Ext InsuM. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.6 0 _ 5 NE=>SW Exterior Concrete Block - Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.6 0 6 NE=>SW Exterior Concrete Block - Ext InS EDROOM 2 4.1 16 0 8 0 128.0 ft2 0 0 0.6 0 7 SE=>NW Exterior Concrete Block - Ext IndIEDROOM 2 4.1 10 0 8 0 80.0 ft= 0 0 0.6 0 8 S=>N Exterior Concrete Block - Ext IndIEDROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0.6 0 9 SW=>NE Exterior Concrete Block - Ext IndilEDROOM 2 4.1 2 0 8 0 16.0 ft2 0 0 0.6 0 10 SE=>NW Exterior Concrete Block -Ext Insul ENTRY 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 11 SW=>NE Exterior Concrete Black -Ext Insul ENTRY 4.1 1 0 8 0 8.0 ft2 0 0 0.6 0 12 SW=>NE Exterior Concrete Block - Ext InsaLAUNDRY 4.1 6 0 8 0 48.0 ft' 0 0 0.6 0 13 NE=>SW Exterior Concrete Block - Ext InsGREAT/DINT 4.1 26 0 8 0 208.0 ft2 0 0 0.6 0 _14 NW=>SE Exterior Concrete Block -Ext InsQRE:AT/DINT 4.1 20 0 8 0 160.0 ft' 0 0 0.6 0 15 N=>S Garage Frame - Wood KITCHEN 11 24 8 192.0 ft2 0.23 0.6 0 11/8/2018 3:28 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST RFPnRT DOORS # Omt Door Type Space Storms U-Value Width Ft In Height Ft In Area 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6 ft' WINDOWS Orientation shown is the entered orientation => chan ed to Worst Case. / Wall V # Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal 2 SW=>NE 4 Metal 3 SE=>NW 7 Metal 4 NE=>SW 13 Metal 5 NW=>SE14 Metal Low-E Single Yes Low-E Single Yes Low-E Single Yes Low-E Single Yes Low-E Single Yes 0.36 0.25 N 32.9 ft' 1 ft 0 in 1 ft 4 in 0.36 0.25 N 6.9 ft' 1 ft 0 in 1 ft 4 in 0.36 0.25 N 24.0 ft' 6 ft 0 in 1 ft 4 in 0.36 0.25 N 37.5 ft' 1 It 0 in 1 ft 4 in 0.65 0.21 N 40.0 ft' 8 It 0 in 1 ft 4 in Drapesiblinds None None None Drapes/blinds Exterior 5 None None None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 315 ft' 315 ft' 24ft 8ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1349.6 74.09 139.34 .2578 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split . HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 34.8 kBtulhr cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SeWnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 11/8/2018 3:28 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT DUCTS _ / — Supply — — Return — Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 250 ft' Attic 65 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programabl[[eX]]Thermostat:Y CApreiling Fans:Cooling Feb Venting Feb Mar[ Mar [Jan ]] Apr Jun Jul rX� [ ] Aug rX� [ ] Sep j ] [[X]] L J Occtt NovrDO, Nov Dec Dec [ ]Jan [ ] X [X] [ ] May Jun Jul [ ] Aug [ 1 Sep lXl [X] [ ] Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(6 Ibs/sq.ft. 0 ft' 0 ft 0.3 BEDROOM Default(8 Ibs/sq.ft. ft' It 0.3 WIC Default(8 lbs/sq.ft. ft' It 0.3 M. BATH Default(8 lbs/sq.ft. fN ft 0.3 KITCHEN Default(8 lbs/sq.ft. ft' ft 0.3 BATH Default(8 Ibs/sq.ft. ft' It 0.3 BEDROOM 2 Default(8 lbs/sq.ft. ft' ft 0.3 ENTRY Default(8 lbs/sq.ft. ft' It 0.3 LAUNDRY Default(8 Ibs1s.ft. ft' It 0.3 GREAT/DINING Name: Test Rater Rating Compant: Test Rater D. 11/8/2018 3:28 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 6 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE GRAND CARLTON Builder Name: WYNNE BUILDING COPR. Street: Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y U Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY w x Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and . continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fodures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind nonino and wirino Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. I Caulking or other adhesive sealants shall not be used to fill voids between fire snrinkler cover rilates and walls or ceilinal; a. In aaaition, inspection or log wails shall be in accordance with the provisions of ICC-400. 11/8/2018 3:28 PM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity 34.8 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1446 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.442 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.239 14. Heating system: Capacity 34.8 c) Area 7c. 141.3 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.97 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 0 Heat recovery unit HeatReC% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 11.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d),Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit 0 Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. (\ ` Builder Signature: Date: Address of New Home` A')' J� H Lys City/FL Zip: FT. PIERCE. FL 11/8/2018 3:28:30 PM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 wrightsoW 'Project Summary Jai Enure House By: QUICK CALCS, INC. 317 ST. LUCIE UN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fa c 772466-6796 Email: QUICKCALCMDAOLCOM For. THE GRAND CARLTON �+ n D/�VELOPMEN PIERCF�r.EL a7CF7BNvNED �WgYNNE Notes: St. Lucie County Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 17848 Btuh Ducts 5654 Btuh Structure Ducts 17520 Btuh 8536 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh none Humidification 0 .Btuh Blower 0Btuh Piping 0 Btuh Equipment load 23503 Btuh Use manufacturer's data n Infiltration Rate/swing multiplier Equipmenf sensible load 0.95 24753 Btuh Method Construction quality Fireplaces Simplified Average 0 Area ft Healtr4n4g Cool'r4n4g m ( Volue ft3) 1251161 125111 Air chahgesfhour 0.45 0.23 Equiv.AVF (cfm) 94 48 Heating Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Model 25HBC536A'030 AHRI ref 7914585 8.5 HSPF 34600 Btuh @ 47°F 27 OF 1160 cfm 0.049 cfm/Btuh 0.50 in H2O point = 32 OF Backup: Input = 7 kW, Output = 23009 Btuh, 100 AFUE Latent Cooling Equipment Load Sizing Structure 3203 Btuh Ducts 2318 Bfuh Central vent (0 cfm) 0 Btuh (none)` Equipment latent load 5521 Btuh Equipment total load 30274 Btuh Req. total capacity at 0.70 SHR 2.9 ton Cooling Equipment Summary Make Carder Trade CARRIERAIR CONDITIONING Cond 25HBC536A`030 Coil FX4DN((B,F)037 AHRI ref 7914585 'Efficiency 12.0 EER, 15 SEER Sensible cooling 24360 Btuh Latent cooling 10440 Btuh Total cooling 34800 Btuh Actual airflow 1160. cfm Air flow factor 0.045 cfm/Btuh Static pressure 0.50' in H2O Loadsensible heat ratio 0.83 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. � " Wtf19F1YSOfY' RlghtSuhe® Uniwrsal 2017 17.0.14 RSUD8101 2017-Apr-11 09:29:38 ...uick CaIcs1Documents1THE GRAND CARLTON-1446.mp Cale = MJ8 Front Door faces: N 9 wrightsoft • RighW@ Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN, FT. PIERCE, FL 34946-Phone: 772-4666799 Fam 772-4666796 Emit: QUICKCALCS@AOLCOM 1 Room name Emirs House BEDROOM 2 EVosed wail 156.2 ft 49.0 If 3 Room height 8.7 ft- d 8.0 ft heat/cod 4 Room dimensions 1.0 x 297.0 ft 5 Room area 1445.5 ft2 297.0 ft2 Ty Consbuctim U-value Or HTM Area (ft2) Load Area (ft2) Load number (BtuhtWF) (Btuh1ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 V11 13A4ms " � �4A.2an,'.... 0.143 :.n: .4.00 ' 255 .: 503 .468 .., .1862 ' - :1184 72 72 - 288 _ t183 .6=G: ..0770 °: h:. -21:58 -'19.31 38,.* 0 .') �815 ._'_730. Oi:.; 0.,-. �'::0 13A4ocs 0.143 a 4.00 255 128 83 333 212 .,"0" - 0 0 0 ` 0 1Ao1am 1270 a 35.56 87.29 24 2 848 2082 0 0 0 0 11 11DO 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 W ,<' - . .- '0.143-se- 4.60 :. '2.55 -. .34 _...-34. 136- .- 86 - -0--� ..0> p.:._. �.._-'.;0 Vy 13A4oas 0.143 s 4,00 2.55 360 353 1414 899 21fi 218 865 550 �--G 1Aciom 1270 s 3556 34.77 7 7 247 241 0 0 0 0 1 13AAocs :. 0 143 w, '. - 4.00 , 255 '-55.21 310 -- 237 ' - 949 '603 104 72 r' 288 183 `1Actan ' .1270 w: 35.56 - 32 :`-. 2:,1140 1770 . 32- 2 1140 1770 0.770 ,. w:: 21.56 -19.31 41 41 - ,_. 8W 788 •0 ' ..01 ,.z0 P 12G-0sw 0.091 - 255 1.28 192 192 489 246 0 0 ,',0 0 - 0 0:: 16430md, ". '0.032 .. , . 0.90 2.32 1446 • 1446 ., 1295 .3354 -297 - 297 266 s . -, 669 F 924-tpl 0.989 27.69 0.00 1446 156 4325 0 - 297 49 . 1357 , 0 6 c)AED mursion 918 627 Ernelope loss/gain 14961 13349 4204 4003 12 a) Mitratim 2887 791 848 - 232 b) Room verRilatim 0 0 .0 0 13 Intemal gains: Occupants @ 230 6 1380 3 690 Applimees/other 2000 0 Subtotal Qines 6 to 13) 17848 17520 5053 4925 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 14 15 Subtotal Duct loads 17848 17520 50 32% 49% 5659 8536 32% 49% 1601 601 2400 2400 Total roan load 23503 26056 6653 7325 Air required(cfm) 1160 1160 328 326 Calculations approved byACCA to meet all requirements of Manual J 8th Ed .4g& 41- wrightsoft- Right-Sulte@ Universal 201717.0.14 RSU08101 2017-Apr-11 09:29:38 ...uick CaIcslDocuments{'DiE GRAND CARLTON-1446.rup Cale = MJB Front Door faces: N Page 1 + wrightsorr • RiOW@ Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 Sr. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email OUICKCALCS@AOLCOM 1 Room name WIC KITCHEN 2 Exaosed wall O it ft 3 Room height &0 It heallcod 8.0 it heaUcool 4 Room rea iors 6.0 x 9.0 it 1.0 x 1720 it 5 Room area ft' 1720 it-54.0 Ty Construction U-value Or HTM Area (ft� Load Area number (Btutyftm (BtuNft') or perimeter (it) (Btuh) or perimeter (it) (Btuh) Heat Cool Gross WPIS Heat Cool Gross WP/8. Heat. Cool 6 i'.13A-0ocs- .,..0143 -n, 4.00 255 ' , .:0: 0 0 '.0 0. �0 : 0 --"o AA5,2cm .'.-;0770 _. n.' s •-2L56;- 19:31 . - 0 :0 :• . 0 " .0 . - -0'- fD''- 0; - ..`4 4�II-� 13AAccs 0.143 a 4.00 255 0 .0 0 0 0 0' 0 0 1AcI m 1.270 a 35.56 87.29 0 0 0 0 0 0 0 0 11 `D 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 W "' M4ccs; .. •.-: 0:143. - se. 4.00-. ,265 ,= -:. -..0 0., -: .. 0 0 -0 .'0 .. 0 ,f;..:.0 W 13AAccs 0.143 s 4.00 255 -0 0 0 0 _.. 0 0 0 0 I--f` tAclan 1270 s 3556 34.77 0 0 0 0 0 0 0 0 13A-06cs =. ..0143 vi ' 4.00 255 ' 0 • ' 0 0 0 0 " �0 :: ' 0 ' 0 `.4AS2orr1: 270 w 35.56 55.21 .o : o' -: o . .: 0 o : a - a ,- : o -A770 W: -21.56 -19.31 0 � '0 ��. . 0 ',0 0 -� :0. �. A ".=0 P 12C Osw 0.091 - 2.55 1.28 0 0 0 0 64 64 163 82 C 16A30md 0.032. -. .0.90 232 54 54 48 125 172 172 154 .. 399 F 22Aapl - 0.959 - 27.69 0.00 54 0 0 0 172 0 0 0 6 c)AED excursion -g -170 Envelope lmsigain 48 117 1 317 311 12 a) MiItralion 0 0 0 0 b) Roomvemilatim 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Applianceslolher 0 2000 Subtotal Dines 6 to 13) 48 117 317 2311 Less ademal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 14 Subtotal 48 117 30 2311 15 Duct loads 32% 49% 15 57 32% 49% 100 00 1126 1126 Total room load 64 174 418 3437 Air required(cfm) 3 8 21 153 Calculations Emmett bvACCA to meet all requirements of Manual J 8th Ed "ft 414- wrighesoft- RlghtSuile® Universal 201717.0.14 RSU081012017-Apr-11 09:29:38 ...uick CalcslDocumentslTHE GRAND CARLTON-1446.mp Colo = We Front Door faces: N Page 2 wrightsoft- Right-M Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772A66-6799 Fax 772-466-6796 Email' OUICKCALCS@AOL.COM, 1 Room name BATH BEDROOM 2 2 =ad wall 5.0 It 34.2 It 3 Raom height S.0 It heat/cool 8.0 It heat/coot 4 Room dimensions 9.0 x 5.0 It 1.0 x 203.5. It 5 Room area 45.0 ft' 203.5 8' Ty Construction U-value Or HTM Ana (ft-) Load Area Load number (BtuhlftMF) (Btuh7fto) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WKS Heat Coal Gross WPIS Heat Cool 6 13A-0ocs -= 0143 n` ' 4.00 255 40 40 160 • - 102 r 128 US L51j " .326 LG ,4A572an ;::- "-0770 �n�..' 2166 r:.. 19.31 '- 0 - .; �0 . 0 0 - 0 ..0; 0 _ -+0 ly 13A4acs 0.143 a 400 Z65 0 0 0 0 80 56 _ 225 - 143 1�-----G D 1Acicrn 1270 a 35.56 87.29 0 0 0 0 24 2 848 2082 11 11DO 0.390 a 10.92 It31 0 0 0 0 0 0 0 0 W . ; -13A-0ocs*' _ - .0.143 .se .....4.00 Z55 0 .. 0 0 ., 0 - 34 .. .<m 136 86 YN 13AAocs 0.143 5 4.00 2.55 - 0 0 0 0 32 32 128 81 �f 1Aclom 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 13A4ocs .0.143 w. . 400 2.55 ' 0 ` 0 0 0 0 > -0, o - 0 .7270 'w .3556 .-.55:21 .0 .: -'•0 0- -0 0 0 0 '0.770 , w ` 21.56 '19.31 0 . 0 -. 0 :, . .0 0 .0 A '- 0 .-0 P 12C-0sw 0.091 - 2.55 1.26 0 0 0 0 0 0 0 0 C - ;16A-30md' 0.032 - 0.90 2.32 45. 45 40 '. 104 204 204 - 182 .472 F 22A4p1 0.9a9 - 27.69 0.00 45 5 138 0 204 34 946 0 6 c)AED eaussion -16 1 -85 Ernelope loss/gain 339 190 1 2978 3106 12 a) Infiltration 87 24 1 593 162 b) Room \entlation 0 0 0 0 13 internal gains: Occupants aQ 23D 0 0 1 230 Applianceslother 0 0 Subtotal (fides 6 to. 13) 425 214 3571 3498 Less mderal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 425 2143498 31 15 Duct loads 32% 49% 135 104 32% 49% 113131 1704 1704 Total rcom lead 560 318 4702 5203 Air required(cfm) 28 14 232 232 Calculations approved bvACCA to meet all reauirements of.Manual J 8th Ed A # wrilght csft- Right-Suhe® Universal 2017 17.0.14 RSU08101 2017-Apr-11 09:29:38 ...nick Coles\Documents\TILE GRAND CARLTON-1448.mp Cale = MJB Front Door faces: N Page 3 wrightsoft° Right-JO Worksheet Job: Entire House Date: ray QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-4666799 Fax 772-4666796 Emil: QUICKCALCS@AOLCOM 1 Room name LAUNDRY GREAT/DINNG 2 Elgwsed wall 6.0 ft 47.0 ft 3 Room height 8.0 ft heat/cool 9.8 ft heat/cool 4 Room dimensians 7.0 x 6.0 ft 1.0 x 526.0 ft 5 Room area 42.0 ft2 526.0 ft2 Ty Construction U-value Or HTM Area Load Arco Load rmmber (BtulVftz*F) (BluWft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 �: '0.143 n-.. '4.00 '. 255 0 0 0 ; 0 .: .. 255' . 217 ` 869 'r':552 4Awone -D.770 n _ "2156 . 1931 :.' -0 �� ' 0 . .0-, '' .0, .. 38„• ..'0: - � 815 . %;730 V '13A-4ocs 0143 . a 4.00 255 0 0 0 0 0 0 0 0 I-C 1A-clam 1.270 a 35.56 87.29 0 0 0 0 0 0 0 0 11 L-D 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 W'.-'13A-4&S 0.143 se r- :4.00 .27.55, ..0 ,:0. 0: 0-. 0 -0'. 0. %`"0 W L-G 13A-4ocs 0.143 s 4.00 2.55 48 48 192 122 0 - 0 0 0 1Aclom 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 134-0oos :0143 w 4.00 .. 2.55 0 0 . 0 0 - 206 165 -' 661 426 -1Actom `- 7 270 w 3556 55.21 -0 :. -0 ' 0 - ' 0 . 0 ; .. 0 , 0 . 0 4A5.2om : :0.770 w -21.56 , 49.31 0 , ,'0 :.. '0 - - .0 41 41 ' sw .. 76s P 12C-0sw 0.091 - 255 1.28 66 56 143 72 - 0 0 0 0 C 16Ah30nld' 0.032 - 0.90 232 '42 42 '38. 97 .526 526 471 1220 F 2ZAApl 0.989 - 27.69 0.00 42 6 166 0 526 47 1302 0 6 c)AED ex=ion -22 .668 Envelope loss/gain 539 270 4997 4379 12 a) Infiltration 104 28 997 273 b) Room ventilation 0 0 '0 0 13 Intemal gains: Occupants @ 230 0 0 2 460 Appliances/other 0 0 Subtotal (rides 6 to 13) 643 298 5994 5112 Less eldemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 Subtotal 643 298 5994 5112 114 151 Duct leads 32% 49% 204 145 32% 49% 1899 24W Total mom load 846 443 7892 7W2 Alr required (cfm) 42 20 390 338 Calculations approved bvACCA to meet all reeuirements of Manual J 8th Ed -Fk wrightSofY RlghtSuite® Universal 2017 17.0.14 RSU08101 2017-Apr-11 0 Page 4 ...uick CaleslDocumentslTHE GRAND CARLTON-1446.mp Cale =MJ8 Front Door faces: N 9 wrightsoft' Right-JO Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-46M799 Fax 772-466-6796 Emil; OUCKCALCS@IOL.COM 1 Room name FOYER M. BATH 2 FF)yosed wall 7.0 it 8.0 ft 3 Room height &0 It heal/Cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 50.0 it 7.0 x 8.0 ft 5 Room area 50.0 ft2 56.0 ft2 Ty Construction U-xalue Or HTM Area Load Am number (Btuh/ft-le) (Btulvft2) or perimeter (ft) (Btuh) or perimeter (it) IBM) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 W � LG'4AS2om. [13AAoos , .0143 .;:0770L "n 4.00 2.55 8'" 8 .,. 32 ,_ 20 0' 0 0 -:i':-.0 . ,' n:. 2156' 19.31 '. -0- 0. - 0 -.0- -0'-" °0.-.. 0 ..;o %J 13A4ocs 0.143 a 4.00 2.55 48 27 108 69 0 0 0 0 tActom 1.270 a 35.56 87.29 0 0 0 0 0 0 0 0 11 L--(D` 11130 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 _ W 134-0acsr 0.143, se' 4.00 _ , 255 -0 -'0 ' --," o '0 0 0 . 0 • :. ; ; 0 W 1344acs 0.143 s 4.00 255 0 0 0 0 64 57 228 145 1"lom 1.270 s 35.66 34.77 0 0 0 0 7 7 247 241 13A 1ocs " :0943 w ,. 4 60 - 255 0 - -0 0 0 0' 0 �: 0 's.0 4Actom '.1270 1w - '3556 65.21 '0 : -0 0 o 10 0 0 `;:6 4lS2om, - .0770 w l-`21.56 19.31 0' 0 '. . 0 ''. 0 . 0 `- o ,p -, d 0 P 12Q-0sw 0.091 - 2.55 1.28 72 72 183 92 0 0 0 0 C .' :',16A30ma. 0.032 - 0.90 2.32 50 50 - 45 116 56 56 50 1w F 22A:tpl 0.989 - Z7.69 0.00 50 7 194 0 56 8 222 0 6 c)AED excursion -39 a8 Envelope loss/gain 792 496 747 478 12 a) bdiltration 121 33 138 38 b) Room wntila0on 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal Qines 6to 13) 913 529 865 516 Less wdemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 913 529 885 516 15 Duct loads 320/6 490/6 289 258 32% 49% 280 251 Told room load 1202 787 1166 768 Air required (aft)59 35 58 34 Calculations approved bvACCA to meet all reauirements of Manual J 8th Ed +�- wrights ft- 2017-Apr-11 09:29:38 RlghtSuitee Universal 201717.0.14 RSUD8101 Page 5 ... ulck CalcsMocuments%THE GRAND CARLTON-1446.rup Cale =MJ6 Front Door fates: N wrightsoft° Duct System Summary Date: Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone:. 772-466-6799 F= 772466-6796 Email: OUCKCALCS@,AOL.COM For. THE GRAND CARLTON WYNNE DEVELOPMENT, FT. PIERCE, FL Extemal static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0,250 / 0.250 in H2O 0.285 in/100ft 1160 cfm Cooling 0.50 in H2O .0 in H2O 0.50`inH2O 0.250 / 0.250 in H2O 0.285 in/100ft 1160 cfm 176 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (In) H x W (jin) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 560 28 14 0.364 4.0 OxO VIFx 22.4 115.0 sN BEDROOM 2 h 4702 232 232 0.360- 7.0 OxO VIFx 23.9 115.0 sit BEDROOM -A h 3327 164 163 - 0.300- 6.0 Ox0 VIFx 31.8 135.0 st2 BEDROOM-B h 3327 164 163 0.285 6.0 OxO VIFx 40.6 135.0 st2 FOYER h 1202 59 35 0.505 4.0 OxO VIFx 4.0 95.0 GREAVDINING h 3946 195 169 0.300 7.0 OxO VIFx 31.8 135.0 st2 GREAT/DINING-A h 3946 195 169 0.300 7.0 OxO VIFx 31.8 135.0 st2 KITCHEN c 3437 21 153 0.379 6.0 OxO VIFx 17.0 115.0 sit LAUNDRY h 846 42 20 0.361 4.0 Ox0 VIFx 23.3 115.0 SO M.BATH-A h 768 58 34 0 0 OxO VIFx 0 0 WIC c 174 3 8 0.309 4.0 Ox0 VIFx 27.0 135.0 st2 Supply Trunk. Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (In) (n) Material Trunk st2 Peak AVF 721 672 0.285 918 12.0 0 x 0 VinlFIX all sit Peak AVF 1043 1091 0.285 1020 14.0 0 x 0 VinlFlx Wrl htSOft` 2o17-Apr-1109:29:38 tC" 9 RightSu8e0 Univema1201717.0.14 RSU08101 Page 1 ...uick Calcs1Documents%THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (n) Stud/Joist Opening Qn) Duct Mad Trunk rb1 Ox0 1 1160 1160 0 1 0 0 0 Ox 0 1 VIFx C Wil htsoft, 2017•Apr-1109:29:38 9 RightSukeO Univarsal 2017 17.0.14 RSU09101 Page 2 ...uick CalosMocumentsITHE GRAND CARITON-1448.mp Calc = MJ8 Front Door faces: N