Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ENERGY EFFICIENCY CODE
FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE STERLING Builder Name: WYNNE DEVELOPMENT SCANNED Street: THE STERLING Permit Office: ST. LUCIE COUNTY �� City, State, Zip: FT. PIERCE -,Permit Owner: _�Q- k- �� Number: Jurisdiction: V. LuC1e COUOly Design Location: FL, Fart Pierce County:: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1442.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ft' b. Frame - Wood, Adjacent R=11.0 192.00 ft' 3. Number of units, if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 2 d. WA R= ft' 5. Is this a worst case? Yes 10. Ceiling Types (1474.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1474.00 ft' 6. Conditioned floor area above grade (ft') 1474 b. N/A R= ft' . Conditioned Floor area below grade (ft') 0 c. N/A R= ft 11. Ducts R ft' 7. Windows(141.3 sqft.) Description Area a. Sup: Attic, Rat: Attic, AH: Attic 6 300 a. U-Factor: Sgl, U=0.63 101.25 ft' SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.65 40.00 ft' 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 34.8 SEER:15.00 c. U-Factor: WA ft' SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft' a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.832 ft. Area Weighted Average SHGC: 0.239 14. Hat water systems 8. Floor Types (1473.5 sgft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1473.50 ft' b. Conservation features EF: 0.970 b. N/A R= ft' None c. N/A R= ft' 15. Credits Pstat Glass/Floor Area: 0.096 Total Proposed Modified Loads: 48.34 PASS Total Baseline Loads: 48.53 1 hereby certify that the plans and specifications covered by Review of the plans and THE STfl� this calculation are in compliance with the Florida Energy specifications covered by this OF 1 g O� Code. on compliance e with thFloi d Endicatnergy PREPA B Before construction is completed r DATE: this building will be inspected for O d y compliance with Section 653.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Codes COp S4L OWNER/� BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 4/17/2018 2:37 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 PROJECT Title: WYNNE THE STERLING Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1474 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 180 Street: THE STERLING Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE _ / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1474 11792 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 329 2632 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M. BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 It 0 329 ft' ____ 0 1 0 2Slab-On-Grade Edge Insulatio WIC 1 ft 0 63 ft' _--_ 0 1 0 3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0 56 ft' 0 1 0 4 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 0 192 fF _- 0 1 0 5 Slab -On -Grade Edge Insulatio BATH 5 ft 0 45 ft' _- 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 ft 0 203.5 ft' ____ 0 1 0 7 Slab -On -Grade Edge Insulatio ENTRY 7 ft 0 55 ft' ___ 0 1 0 4/17/2018 2:37 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 FORM R406-2017 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio LAUNDRY Eft 0 42 ft2 ___ 0 1 0 9Slab-On-Grade Edge Insulatio GREAT/DINING 46 ft 0 488 ft2 ___ 0 1 0 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color ABsor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1553 ft2 246 ft2 Light 0.6 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 160 1474 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 329 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic (Vented) M.BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 192 ft2 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 55 ft2 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 9 Under Attic (Vented) GREAT/DINING 30 Blown 488 112 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 NE=>SW Exterior Concrete Block - Ext Ins®EDROOM 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 2 SW=>NE Exterior Concrete Block - Ext InS®EDROOM 4.1 28 0 8 0 224.0 ft2 0 0 0.6 0 3 NW=>SE Exterior Concrete Block - Ext Ins®EDROOM 4.1 14 0 8 0 112.0 ft2 0 0 0.6 0 4 SW=>NE Exterior Concrete Block - Ext InsuM. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.6 0 5 NE=>SW Exterior Concrete Block - Ext Insul BATH 4.1 5 0 8 0 40.0 ft' 0 0 0.6 0 6 NE=>SW Exterior Concrete Block - Ext InQEDROOM 2 4.1 16 0 8 0 128.0 ft' 0 0 0.6 0 7 SE=>NW Exterior Concrete Block - Ext InQEDR00M 2 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 8 S=>N Exterior Concrete Block - Ext In!8ffDROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0.6 0 9 SW=>NE Exterior Concrete Block - Ext In!BffDROOM 2 4.1 2 0 8 0 16.0 ft2 0 0 0.6 0 10 SE=>NW Exterior Concrete Block - Ext Insul ENTRY 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 11 SW=>NE Exterior Concrete Block - Ext Insul ENTRY 4.1 1 0 8 0 8.0 ft2 0 0 0.6 0 12 SW=>NE Exterior Concrete Block - Ext InsdIAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 _ 13 NE=>SW Exterior Concrete Block - Ext Ins REAT/DIN] 4.1 26 0 8 0 208.0 ft2 0 0 0.6 0 _14 NW=>SE Exterior Concrete Block -Ext Ins REAT/DINI 4.1 20 0 8 0 160.0 ft2 0 0 0.6 0 15 N=>S Garage Frame - Wood KITCHEN 11 24 8 192.0 ft2 0.23 0.6 0 4/17/2018 2:37 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 DOORS # Ornt Door Type Space Storms U-Value Width Ft In Height Ft In Area 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. / Wall V # Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal 2 SW=>NE 4 Metal 3 SE=>NW 7 Metal 4 NE=>SW13 Metal 5 NW=>SE14 Metal Low-E Single Low-E Single Low-E Single Law-E Single Law-E Single Yes Yes Yes Yes Yes 0.63 0.25 N 32.9 ft2 1 It 0 in 1 ft 4 in 0.63 0.25 N 6.9 ft2 1 It 0 in 1 ft 4 in 0.63 0.25 N 24.0 ft2 6 ft 0 in 1 It 4 in 0.63 0.25 N 37.5 ft2 1 ft 0 in 1 ft4 in 0.65 0.21 N 40.0 ft2 8 ft 0 in 1 ft 4 in Drapes/blinds None None None Drapes/blinds Exterior 5 None None None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 315 ft2 315 ft2 24ft 8ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1375.7 75.53 142.04 .2598 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 4/17/2018 2:37 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 . FORM R405-2017 DUCTS / --- Supply -- — Return — Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 300 ft- Attic 75 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programabl�e Crreiling Fans: Cooling]]Thermostat: eat ng `X) Jan ]Y EX] Feb r' [X] Mar Jun Jul Aug 44 ]] ct rD[[�(]] Dec Venting [` f) Jan [ 1 Feb [Xl Mar Apr [ May lXl Jun LX1 Jul lXl Aug lXl Sep Oov lX Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (wD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 4/17/2018 2:37 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE STERLING Builder Name: WYNNE DEVELOPMENT Street: THE STERLING Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealingmaterial. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per inch Knee walls shall be sealed. minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac Be. Recessed lighting Recessed light factures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind ninqnn and wirino Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exteriorwalls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover niateq and walls or ceilingi; a. [I] duuuun, mspemion or log walls snail be in accordance with time provisions of IGG-400. 4/17/2018 2:38 PM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. THE STERLING, FT. PIERCE, FL, 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Fxd Insul, Exterior R=4.1 1250.00 ft' b. Frame - Wood, Adjacent R=11.0 192.00 ft' 3. Number of units, if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 2 d.N/A R= ft' 5. Is this a worst rase? Yes 10. Ceiling Types Insulation Area a. Under Attic (Vented) R=30.0 1474.00 ft- 6. Conditioned floor area (ft') 1474 b. N/A R= ft' 7. Windows- Description Area c. N/A R= ft' a. U-Factor: Sgl, U=0.63 101.25 ft' 11. Ducts R ft' SHGC: SHGC=0.25 a. Sup: Attic, Ret: Attic, AH: Attic 6 300 b. U-Factor. Sgl, U=0.65 40.00 ft' SHGC: SHGC=0.21 12. Cooling systems kBtu/hr Efficiency c. U-Factor. N/A ft' a. Central Unit 34.8 SEER:15.00 SHGC: d. U-Factor: N/A ft' SHGC: 13. Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 3.832 ft. a. Electric Heat Pump 34.8 HSPF:8.50 Area Weighted Average SHGC: 0.239 8. Floor Types Insulation Area 14. Hot water systems a. Slab -On -Grade Edge Insulation R=0.0 1473.50 ft a. Electric Cap: 40 gallons b. NIA R= ft' EF: 0.97 c. N/A R= ft: b. Conservation features None 15. Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date Address of New Home: City/FL Zip:��� *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/17/2018 2:37 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1 wrightsProject SummaryJob: Oftm Entire House Date: QUICK.CALCS, INC. 317 SL LUCIE I.M. FT. PIERCE, FL 34946 Phone: 772-46"799 Fax 772-06S6796 Email OUICKCALCSCaAOLCOM For. WYNNE DEVELOPMENT BY THE CARLTO 9, FT. PIERCE, FL St. Lucie Counh Notes: � �I sq:� Design Information Weather. Winter Design Conditions Outside db 42 OF Inside db. 70 OF Design TD 28 OF Heating Summary Structure 18188 Btuh Ducts 5654 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 23842 Btuh Infiltration Fort Pierce, FL, US Method Simplified Construction quality Average Fireplaces 0 Area ft He1474 Co 1474 Volume (ft3) 12227 12227 Airchanges/hour 0.45 0.23 Equiv. AVF (cfm) 92 47 Heating Equipment Summary Make Carder Trade CARRIER AIR CONDITIONING Model 25HBC536A•030 AHRI ref 7914585 Efficiency " Heating input Heating output Temperature rise Actual airflow Airflow factor Static pressure Space thermostat Capacity balance point = 33 OF 8.5 HSPF 34600 Btuh @ 470F 27 OF 1160 cfm 0.049 cfm/Btuh 0.50 in H2O Backup: Input = 7 kW, Output = 23009 Btuh, 100 AFUE Summer Design Conditions Outside db 90 OF Inside db 75 OF, Design TD 15 OF Daily range Relative humidity L 50 Moisture difference 61 % gr/lb Sensible Cooling Equipment Load Sizing Structure 17877 Btuh Ducts 853 Centrral vent (0 cfm) 0: Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swingg multpplier Equipmentsensiile load 0.95 25093 Btuh Latent Cooling Equipment Load Sizing Structure 2958 Btuh Ducts 2319. Btuh Central vent (0 cfm) -0* Btuh (none). Equipment latent load 5277 Btuh Equipment total load 30370 Btuh Req. total capacity at 0.70 SHR 3.0 ton Cooling Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Cond 25HBC536MO30 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 12.0 EER, 15 SEER Sensible cooling 24360 Btuh Latent cooling 10440 Btuh Total cooling 34800 Btuh Actual. airflow 1160 cfm Air flow factor 0.044 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.83 Calculations approved byACCA to meet all requirements of Manual J 8th Ed �. Wrightsoft' - 2017-Apr.1017:14:53 RI9MSuite® Unlversa12077 77.0.74 RSU08101 ...Wdghtso6 HUACMYNNE•THE GRAND CARLTON-299.tup Cale = MJ8 Front Door faces: N Page 1 wrightsoft* Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. y., 1 Room name Entire House BEDROOM 2 EVosedwall 156.2 ft 520 ft 3 Room height 1 &3 ft d 8.0 ft heaticool 4 Room dimensions 1.0 x 329.0 It 5 Room area 1473.5 W 329.0 ft' TV cmtIltm U-%Mlue Or Am (ft2) Load Area (ftq Load fflmb� I (BtUWfVL*F) PgtThV'MfF) - or Wmeter (ft) (Stun)_ a perimeter (ft) (Stuh) Heat coal Gross NIP/S Heat Cool Gross N/P/S Halt Cod 6 13AAods, 0.143 no- ".4.00 ��ZBS 479 .. 442 1768, , .-,1124 �::'80 "80 204 -1270 ho, -H--35.56 �',�_70.43 38 0, ; '-,1344 �,-2662 e 0_ 7�� %J�j 13AA= 0.143 se 4.00 2 55 128 83 331 210 0 '0 0 0 0 IA-clm 1.270 as 35.56 34.77 2,4 48 848 829 0 0 0 0 1 11DO 0.390 so 10.92 11.31 22 22 236 244 0 a 0 0 Z13AA46=' - - - , , - , %0:143 ,i.: 400 265 ..34 '360 34 136 86 0 01- 0z0 Y—a 13kAocs 0.143 sw 4.00 265 353 1414 899 224 224 897 570 IAclorn 1270 sw 35.66 42.91 7 11 247 298 0 0 0 0 13446&9-.0i143 1 -- nw' ',4.00 "zL3556 -'2 55 a24 -,'290 217 867 551 1112 -318 202 w '4A5- .:1.270 lmv� .33 P f 162 �1478 �W �1162, �`,A479 , -07,70 21:56 ,27.54 i4t 0 1124 �0 11 10 p 12G-0sw 0.091 Z55 1.28 192 192 489 246 0 0 0 0 �11 C��' , _-'jGA-3bfiid - , , AM —0.90 .232 1474 1474 -1320 .3419 '329 •M 295 F ?2AApl 0.9m 27.69 0.00 1474 156 4325 0 329 52 1440 0 C)AED emurslon 784 680 Envelop lossfgaln imm 13954I 44M 3897 12 a) Infiltration 2822 7731 gm 20 b) Room ventilation a 01 0 13 hemal gains: Occupants @ 230 5 1150 2 460 Applimoeslother 20M 0 Subtotal oines, 6 to 13) 18188 17617 5341 4606 Less odemal load 0 0 0 01 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 18188 17877 5341 4606 15 Duct loads 31% 48% 56541 .8536 31%1 48% 1660 2199 Calculations approved by ACCA to meet all requirements of Manual J, 8th Ed. A& wVlahr:seof V Right-SufteS Unimmal 201 7 17.0.14 RSU08101 2017-Apr-10 17:14:53 ... Wrightsoft WACIWYNKE-THE GRAND CARLMN-299.mp Calo=MJS From Door faces: N Page 1 wrightsoft Right-J@ Worksheet Job: Entire House Date: QUICK CALCS, INC. sy: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fa,c 772<66-6796 Eneik OUICKCALCS@AOLCOM 1 Room name WIC M. BATH 2 FBosed wall Oft 8.0 ft 3 Room height 8.0 ft heatfcod 8.0 ft heaVcod 4 Room dimensions ions 7.0 x 9.0 It 7.0 x 8.0 fit 5 a Room area 63.0 ft2 56.0 ft' Ty Construction U-%slue Or HTM Area Area number (StutyfP F) (Btulvft9 or perimeter (ft) (BtBtuh) or perimeter (ft) (BttUh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool s Vy L--C" 0.143 :,no --400 ,2.55 -0 ..0 0.0 0.. 0.;. 0 �A 16m� �:.. - `,1.270 nee ' =3556 : .70.43 : ---0 -. -0'. - 0.- ;0 0 ��' .0.o ,<-0 0 13A4= 0.143 se 400 255 0 0 0' 0 0 0 0 ." 0 1A-c1cm 1.270 se 35.56 34.77 0 0 0 0 0 0 0 0 11 11DO 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 W x' �13A ,0143: s`. 4.00 ' 255 _ .0 :o o : o. 0 - '. 0' .. p 13AA= 0.143 sw 4.00 255 0 0 . 0 0 64 57 228 .145 L—�a 1Ac1om 1.270 sw 3556 4291 0 0 0 0 7 s 247 296 - 13A-0acs ;1Ac1om -0.143 -mv :.. 400 255 `D 0 0 :0 0 - 0 0 :-0 '4AS2orrh` ;1.Z70 - w 35.56 45.24 -0' ' 0 .: 0 •0 0 - 0 : 0 , .p 0.770'nw - z1.56 . i27. 0 0. ." o 0 0 0.. 0 0 P 12C-0sw 0.091 - 255 tea 0 0 0 0 0 0 0 4 0 C `.. ::. :16AI30md" '0.032 •- .0.90 232 63 63 56 146 - '56 -56- s0 j130 F 22htpl, _. 0.989 - 27.69 0.00 p 0 _ 0 0 56 8 222 0 6 c)AED e)=Icn -p 225 Envelope loss/gain 56 145 747 798 12 a) Infiltration 0 0 140 38 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Applianceslother p 0 Subtotal nines 6 to 13) 56 145 887 836 Less adernal load 0 0 0 0 Less transfer 0 0 0 0 Redishibutim 0 0 14 -Subtotal 56 145 887 836 15 Duct loads 31% 48% 18 69 31q 48% 276 399 Told mom bail 74 214 1162 1235 Air required(cfm) 4 9 57 54 �g Calculations approved byACCA to meet all requirements of Manual J Sth Ed /4G A 4t- wrightsoft- Right -Sucre® Universal 201717.0.14 RSU081012017-Apr-1017:14:53 ...Wdghtsoft FNACIWYDAIE-THE GRAND CARLTON-299.rup Colo v MJB From Door faces: N Page 2 wrightsofr ' Right-J® Worksheet Job: Entire House Date: sy: QUICK CALCS, INC. 317 ST. LUCIE UN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 7724665796 Email: QUICKCALCS@AOLCOM 1 Room name ICTCHEN BATH 2 F)osed wall 0 ft 5.0 ft 3 Room height 8.0 ft heal/cool 8.0 It heat/cool 4 Room dimensions 1.0 x 192.0 ft 9.0 x 5.0 ft 5 Room area 192.0 ft2 45.0 ft2 Ty Construction U-value Or HTM Area (ftj Load Area (ft2) Load number (Btuh/fli°F) (BU11M or perimeter (ft) (Btuh) or perimeter -(ft) (Btuh) Heat Cool Gross WP/S Heal Cool Gress WP/S Heat Cool 6 Vi1 13AAocs .; -0143 ne .4.00 - 255 0 0 ' ' 0 : i0 40' 40 .. 160 ilm iIAolam. ; " -13AAocs .1.270 ne- .: '35.56 ' 70.43 '. .:0' " ' 0'. . 0 ....0 ..D :: 0 s.:.. 0 a ' o %il 0.143 as 4.00 255 0 0 0 0 0 0 0- 0 IL-, 1Aotom 1.270 as 35.56 34.77 0 0 0 0 0 0 0 0 11 11DO 0.390 as 10.92 11.31 0 0 0 0 0 0 0 0 W1 - : ;134-0oCs 0.143 •S:(,.''-4.00 ' _. 255 :' 0 '0 : < . '-0 .. ;0 0 ---0 , 0 :. D W 13A-0ocs 0.143 sw' 4.00 255 0 0 0 0 0 0 0 0 I--f' 1Ao1an 1270 sw 3556 42.91 0 0 0 0 0 0 0 0 �13A-0acs 0143 rrvi '=. 400 255 0`. 0 0 .0 p', 0 < 0 s_:p 1Ao1om 27o my ':. 35.56 ' -45:24 .0 ' 0 0 .9 0 : 0 - 0 �. 7:�0 2156 ' .2754 '0' 0 =. . 0 - .0 .0 - o - 0 'io P _ 12C-0sw 0.091 - 255 64 64 82 b 0 0. 0 0.032' -=` 0.90 _1.28 `, 232 ,: '192 192 ,163 .. 472 . 445. .-45- ...,,45 ;. .40 ° ..., 104 F 27A-tpl 0.989 - 27.69 0.00 192 0 0 0 45 5 138 0 6 c)AED excursion -27 -2 Envelope loss/gain 335 501 339 204 12 a) Infiltration 0 0 87 24 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants Qc 230 0 0 0 0 Appliances/other 2000 0 Subtotal Dines 6 to 13) 335 2501 426 228 Less mdemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 335 2501 426 228 15 Duct leads 31% 48% 104 1194 31% 48% 133 109 Total room load 439 3695 559 336 Air required(drr) 21 112 27 75 Calculations approved bvACCA to meet all recuirements of Manual J 8th Ed .�-*� wrightsoft- 2017-Apr-1017:14:53 A RlghtSuiteO Universal 2017 17.0.14 RSU08101 Page 3 ...Wrightsolt HVAMWYNNE-THE GRAND CARLTON-299.mp Cale =MJ8 Front Door faces: N wrigiitsoft, Right-M) Worksheet Job: Entire House Data` By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 7724666799 Farc 772A666796 Email: QUICKCALCS@IOL.COM 1 Room name BEDROOM 2 ENTRY 2 F19osed wall 32.2 it 7.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft healfcool 4 Room dimerrsions 1.0 x 203.5 It 1.0 x 65.0 ft 5 Room area 203.5 ft- 55.0 ft' Ty Construction U-value Or FITM Area (ft5 Load Area (ft5 Load number (Btuh1WF) (BtulJft.) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross NOS Heat Cad Gross WP/S. Heat Cod 6 13A46cs 0.143 no' -4.00 2.65 .128 - 128 513 - - . , 326 0, 0 15270 ne, -.. 3556 ' 70.43 .. '0 " 0 - 0 0 - i ' 0' 0 � " ° 0 ' "= 0 V)/ 13A4= 0.143 se 400 . 255 80 56 225 143 48 26 106 67 IL-GD 1Ac1an 1.270 se 35.56 34.77 24 24 848 829 0 0 0 0 11 11DO 0.390 se 10.92 11.31 0 0 0 0 22 22 236 244 W :'-, ':13A--4=: .. ,. 0.143',,a. .4.06 2.65-.. -34 $4 136, ,. .86 ;. ...0, 0:,:,,. 0 tz' :=0 4dI 13A-4ocs 0.143 sw 4.00 255 16 16 64 41 8 8 32 20 LG 1Ac1cm 1.270 sw 35.56 42.91 0 0 0 0 0 0 0 0 13AAoc; .0:143 nw 4.00 255 0 0 - 0 .0 0 0 -. " 0 =0 1A-clorn "]:270 my ,.35.66 ' 45.241 i0 ; 0 .: 0 s ° 0 . ' .. -0 0 '0 r0 �4A5-tam J. ,0:770 nw, . 29 56 ' {, 27.54 0, 0 .0 - 0 ' . 0 .0 -. 0 �0 P 12C-0sw 0.091 - 255 1.28 0 0 0 0 72 72 183 92 C •16A-30md 0.0u - 0.90 232 204 204 - 182 . 472 55 55 49 F 22A-tpl 0.989 - 27.69 0.00 204 32 891 0 55 7 194 0 6 c)AED excursion -24 -8 Envelope loss/gain 2859 1873 800 545 12 a) infiltration 664 164 122 34 b) Room ventilation 1 0 0 0 0 13 Internal gains: Occupants Q 230 1 230 0 0 Appliances/other 0 0 Subtotal Pines 6 to 13) $422 22,57 922 579 Less odemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 3422 2257 922 679 15 Dud loads 31% 48% 1064 1078 31% 48% 287 276 Total room load 42 3335 1209 855 Air required(cfm) 218 14fi 59 38 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. wriyhtLs ft' 2017-Apr-1017:14:53 . h Right-Suite®Universal 17RSU08101 Page4 ...WdghtsoR HVACIWVNNE•THE GRAND CARLTO&299.m9.mp Calc Calc = MJB Frant Door faces: N +wrightsoft° Right-.J®Worksheet Job' Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE I.R. FT. PIERCE. FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: ONCKCALCS@AOL.COM 1 Room name LAUNDRY GREAT/DWING 2 F)osed wall 6.0 ft 46.0 ft 3 Room height 8.0 ft heal/cod 8.9 ft heaUcool 4 Room dimensions 7.0 x 6.0 ft 1.0 x 488.0 ft 5 Room area 42.0 ft- 488.0 ft- Ty ConsUuctim U-value Or HTM Am (ftj Load Area Load numbs (BtuNft-°F) (BtuNit') a perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross NOS Heat Cod Gross WPIS Heat Cod 6 VW 13AAocs - : ' 0.143 1,ne. 4.00 ' .2.55 0 ; - 0 . ;. 0 ' ' `0 231 .. 194 . 775 ' ,493 . :7Ac1om - - t>270 rie; . 35.56 -, :70.43 0 ' : --0 - .. 0 . .0 - '. 38 ` . 0 -'- -1344 ' 2(62 V jI�C 13A-4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0- 0 0 1Actom 1.270 se 35.66 34.77 0 0 0 0 0 0 0 0 11 `D 11DO 0.390 as 10.92 11.31 �0 0 0 0 0 0 0 0 W 13A4ocs::, ' 6143 's. ; ..4.00 " .t255 :. - 0 - 0 . 0 ;r - 0 . . 0 ,..... .. -0 0 t2/ L-G 13A-4ocs 0.143 sw 4.D0 255 48 48 192 122 0 - 0 0 0 1Actom 1.270 sw 35.56 4291 0 0 0 0 0 0 0 0 ]3A-0ocs"'' :0:143 my •'40D 255: 0; 0 ' -. 0 :0 178" 137 ;" -549 '349 tAclom .. -^ 1:270 nw f..3556 45.24 . .o .. 0 ..: 0 a 0 -� - 0 -. 0 . -0 4A.5;2om 0.770 my - 21.56 ! 27:54 -0 :" 0 ' - 0 :0 41 j - 0-- 880 11124 P 12C-0sw 0.091 - 255 1.28 56 56 143 72 0 0 0 , 0 C `616A-Wand -0.032 - 0.90 232 42 42 38 - 97 ._ 488 488 437 - .1132 F 22A-lpl 0.989 - 27.69 0.00 42 6 166 0 488 46 1274 0 6 c)AED murslon S -66 Envelope loss/gain 539 288 5259 6704 12 a) Idthation 105 29 895 245 b) Room ventilation 0 0 0 0 13 btemal gains: Occupants @ 230 0 0 2 46D Appliancestother 0 0 Subtotal (lines 6 to 13) 644 317 6154 6409 Less eldemal load 0 0 0 0 Less transfer 0 0 0 0 Redishlbutim 0 0 0 0 14 Subtotal 644 317 6154 6409 15 Duct loads 31% 48% 200 151 31% 48% 1913 3060 Told morn load 844 468 8067 9469 Air required(cfm) 41 21 393 416 Calculations approved byACCA to meet all requirements of Manual J-8th Ed. A wrightSofY RlghtSuite® Universe] 201717.0.14 RSU08101 2017-Apr-101 Page 5 ...Wdghtso4 WAC\WYNVE-THE GRAND CARLTON-299.mp Cole =MJ8 Front Door faces: N _ -- wrightsoft Duct System Summary Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-4666799 Fax 7724666796 Etreit: QUICKCALCS AOL.COM Froject intormation For. WYNNE DEVELOPMENT THE CARLTON 299, FT. PIERCE, FL Job: Date: By: Heating Cooling Extemal static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply / return available pressure 0.250 / 0.250- in H2O 0.250 / 0.250 in H2O Lowest friction rate 0.284 in/100ft 0.284 in/100ft Actual airflow 1160 cfm 1160 cfm 'Total effective length (rEL) 176 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Dlam Qn) H x W (In) Duct Mat! Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 559 27 15 0.376 4.0 Ox0 VIFx 18.1 115.0 st1 BEDROOM 2 h 4486 218 146 0.374 6.0 0x0 VIFx 18.6 115.0 st1 BEDROOM -A h 3501 170 149 0.297 6.0 Ox0 VIFx 33.1 135.0 st2 BEDROOM-B h 3501 170 149 0.284 6.0 0x0 VIFx 41.1 -135.0 st2 ENTRY h 1209 59 38 0.510 4.0, 0x0 VIFx 3.0 95.0 GREAVDINING C 4735 196 208 0.318 7.0 0x0 VIFx 22.4 135.0 st2 GREAVDINING-B c 4735 196 208 0.307 7.0 OxO VIFx 28.1 135.0 st2 KITCHEN C 3695 21 162 0.375 7.0 Ox0 VIFx 18.3 115.0 st1 LAUNDRY h 844 41 21 0.366 6.0 Ox0 VIFx 21.6 115.0 st1 M•BATH h 1162 57 54 0.366 4.0 Ox0 VIFx 21.6 115.0 st1 wic C 214 4 9 0.310 4.0 Ox0 VIFx 26.3 135.0 st2 Supply Trunk Detail Table Trunk Htg. Clg Design Veloc Diam H x W Duct Name Type (cfm) (Cfm) FR (fpm) (In) pn) Material Trunk st2 Peak AVF 737 724 0.284• 689 14.0 0 x 0 VinlFlx st1 st1 Peak AVF 1101 1122 0.284 804 16.0 0 x 0 VinlFlx ' f wrightSoft' RightSuite® Universal 201717.0.14 RSU08101 2017-Apr-1017:age 1 "05i Page ...Wnehtsoft HVACIWYNNE-THE GRAND CARLTON-299.mp Calc=MJ8 Front Door faces: N Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud(Joist Opening (in) Duct Matl Trunk lb1 OxO 1 1160 1160 0 1 0 0 0 Ox 0 1 VIFx t Wrl htsOft• 2017-Apr-1017:14:64 . 9 RightSuite® Universal 2017 17.0.14 RSU08101 Page 2 ...Wrightsolt HVAC\WYNJEBHE GRAND CARLTON-299.rup Calo=MA Front Door faces: N