'FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE THE WINDSOR IMPACT
Builder Name: WYNNE DEVELOPMENT
C+[� r�'p�l�ry
Street: THE WINDSOR
Permit Office: ST. LUCIE COUNTY
SCANNED
City, State, Zip: PIERCE1'FL
`Owner:
Permit Number:
BY
i�iS2s't��0'"�
Jurisdiction:
St. Lucie
Design Location: FL, Fort Pierce
bounty
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1432.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1224.00 ft2
b. Frame - Wood, Adjacent
R=11.0 208.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
5. Is this a worst case? Yes
10. Ceiling Types (1753.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1753.00 ft2
6. Conditioned floor area above grade (ft2) 1753
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c.
R= 2
11. Ducts
R ft2
7. Windows(151.4 sgft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 250
a. U-Factor: SgI, U=0.63 111.36 ft2
SHGC: SHGC=0.25
b. U-Factor. SgI, U=0.65 40.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
34.8 SEER:15.00
c. U-Factor. WA ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: WA ft2
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 2.850 ft.
Area Weighted Average SHGC: 0.239
14. Hot water systems
8. Floor Types (1753.0 sqft.) Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ft2
b. Conservation features
EF: 0.970
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Total Proposed Modified Loads: 52.93
Glass/Floor Area: 0.086
PASS
Total Baseline Loads: 53.85
I hereby certify that the plans and specifications covered by
Review of the plans and
SrgT�
this calculation are in compliance with the Florida Energy
specifications covered by this
0441iE
_ O�
Code.
calculation indicates compliance
with the Florida Energy Code.
PREPARPP B
Before construction is completed
r d
DATE: -
this building will be inspected for
a- y
1
compliance with Section 553.908
°
I hereby certify that this building, as designed is in compliance
Florida Statutes.
with the Florida Energy Code.
G`Op WE
OWNERMT.
BUILDING OFFICIAL:
DATE:' -
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
11/19/2018 2:39 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: WYNNE THE WINDSOR IMP Bedrooms: 3
Address Type:
Street Address
Building Type: User
Conditioned Area: 1753
Lot #
Owner Name:
Total Stories: 1
Block/Subdivision:
#-of Units: 1
Worst Case: Yes
PlatBook:
Builder Name: WYNNE DEVELOPMENT Rotate Angle: 225
Street:
THE WINDSOR
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
,Jurisdiction:
Whole House Fan: No
City, State,
Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location
TMY Site 97.5 %
2.6 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1753 14024
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
Infil ID
Finished Cooled
Heated
1 MASTER BEDR00
224 1792 No
0
1
1
Yes
Yes
Yes
2 WIC
63 504 No
0
1
No
Yes
Yes
3 MASTER BATH
56 448 No
0
1
Yes
Yes
Yes
4 M. BATH
61 488 No
0
1
Yes
Yes
Yes
5 LAUDRY
36 288 No
0
1
No
Yes
Yes
6 BEDROOM 2
180 1440 No
0
1
1
Yes
Yes
Yes
7 DINING/GREATR
588 4704 No
2
1
Yes
Yes
Yes
8 KITCHEN
209 1672 Yes
0
1
Yes
Yes
Yes
9 BATH
50 400 No
0
1
Yes
Yes
Yes
10 HALL
25 200 No
0
1
No
Yes
Yes
11 FOYER
92 736 No
0
1
Yes
Yes
Yes
12 BEDROOM 3
169 1352 No
0
1
1
Yes
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
MASTER BEDRO 37 ft 0
224 ft'
—
0 1
0
- 2 Slab -On -Grade Edge Insulatio
WIC 1 ft 0
63 ft'
___
0 1
0
3 Slab -On -Grade Edge Insulatio
MASTER BATH 8 ft 0
56 ft'
____
0 1
0
4 Slab -On -Grade Edge Insulatio
M. BATH 7 ft 0
61 ft'
-_
0 1
0
5SIab-On-Grade Edge Insulatio
LAUDRY 1 ft 0
36 ft'
___
0 1
0
11/19/2018 2:39 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 2 of 6
rORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
6 Slab -On -Grade Edge Insulatio
BEDROOM 2 12 it
0
180 ft2
__-
0
1
0
7 Slab -On -Grade Edge Insulatio
DINING/GREAT 50 it
0
588 ft2
-_
0
1
0
8SIab-On-Grade Edge Insulatio
KITCHEN lift
0
209 ft2
___
0
1
0
•
9Slab-On-Grade Edge Insulatio
BATH 5 it
0
50 ft2
0
1
0
10SIab-On-Grade Edge Insulatio
HALL t It
0
25 ft2
0
1
0
11SIab-On-Grade Edge Insulatio
FOYER 9 It
0
92 ft2
-_
0
1
0
12SIab-On-Grade Edge Insulatio
BEDROOM 3 14 ft
0
169 ft2
___
0
1
0
ROOF
/
Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
V
# Type Materials Area
Area
Color
Absor. Tested
Tested
Insul.
(deg)
1 Gable or Shed Metal 1847 ftz
292 ft'
Light
0.6
No
0.9
No
0
18.4
ATTIC
/
V
# Type
Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic
Vented
150
1753 ft2
N
N
CEILING
# Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1 Under Attic (Vented)
MASTER BEDRO
30
Blown
224 ft2
0.1
Wood
2 Under Attic (Vented)
WIC
30
Blown
63 fN
0.1
Wood
3 Under Attic (Vented)
MASTER BATH
30
Blown
56 ft'
0.1
Wood
4 Under Attic (Vented)
M. BATH
30
Blown
61 ft2
0.1
Wood
5 Under Attic (Vented)
LAUDRY
30
Blown
36 ft2
0.1
Wood
6 Under Attic (Vented)
BEDROOM 2
30
Blown
180 ft2
0.1
Wood
7 Under Attic (Vented)
DINING/GREAT
30
Blown
588 ft2
0.1
Wood
8 Under Attic (Vented)
KITCHEN
30
Blown
209 ft2
0.1
Wood
9 Under Attic (Vented)
BATH
30
Blown
50 ft2
0.1
Wood
10 Under Attic (Vented)
HALL
30
Blown
25 ft2
0.1
Wood
11 Under Attic (Vented)
FOYER
30
Blown
92 ft2
0.1
Wood
12 Under Attic (Vented)
BEDROOM 3
30
Blown
169 ft2
0.1
Wood
WALLS
Adjacent
Space Cavity Width
Height
Sheathing Framing
Solar
Below
_ 1
NE=>W Exterior Concrete Block
- Ext InEMASTER BE
4.1 16
0 8
0
128.0 ft2
0
0
0.4
0
2 '
SW=>E Exterior Concrete Block
- Ext InNASTER BE
4.1 7
0 8
0
56.0 ft'
0
0
0.4
0
3
NW=>S Exterior Concrete Block
- Ext InddASTER BE
4.1 14
0 8
0
112.0 ft'
0
0
0.4
0
4
NE=>W Exterior Concrete Block
- Ext IndMASTER BA
4.1 8
0 8
0
64.0 ft'
0
0
0.4
0
11/19/2018 2:39 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 6
rORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent Space
Cavity Width
Height
Sheathing Framing Solar
Below
5
NE=>W Exterior
Concrete Block - Ext InsuM. BATH
4.1 7
0
8 0
56.0 ft'
0
0
0.4
0
• 6
NE=>W Exterior
Concrete Block - Ext IndIffDROOM 2
4.1 12
0
8 0
96.0 ft'
0
0
0.4
0
7
SW=>E Exterior
Concrete Block - Ext IndWNING/GRE
4.1 30
0
8 0
240.0 ft'
0
0
0.4
0
8
•
NW=>S Exterior
Concrete Block - Ext InQdNING/GRE
4.1 20
0
8 0
160.0 ft'
0
0
0.4
0
9
SW=>E Exterior
Concrete Block - Ext InsuKITCHEN
4.1 11
0
8 0
88.0 ft'
0
0
0.4
0
10
NE=>W Exterior
Concrete Block - Ext Insul BATH
4.1 5
0
8 0
40.0 ft'
0
0
0.4
0
11
SE=>N Exterior
Concrete Block - Ext Insul FOYER
4.1 8
0
8 0
64.0 ft'
0
0
0.4
0
12
SW=>E Exterior
Concrete Block - Ext Insul FOYER
4.1 1
0
8 0
8.0 ft'
0
0
0.4
0
13
NE=>W Exterior
Concrete Block - Ext InSEDROOM 3
4.1 13
0
8 0
104.0 ft'
0
0
0.4
0
14
SW=>E Exterior
Concrete Block - Ext InfiffDROOM 3
4.1 1
0
8 0
8.0 ft'
0
0
0.4
0
15
N=>SW Garage
Frame - Wood BEDROOM 3
11 26
8
208.0 ft'
0.23
0.4
0
DOORS
# Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft In
Ft In
1 SE=>N Insulated FOYER
None
.39
3
3
6 8
21.7 ft'
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
Wall
Overhang
V
# Omt ID
Frame Panes NFRC U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1 NW=>S 3
Metal Low-E Single Yes
0.63 0.25
N
32.4 ft'
1 It 0 in
1 it 4 in
Drapes/blinds
Exterior 5
2 NE=>W 5
Metal Low-E Single Yes
0.63 0.25
N
6.9 ft'
1 it 0 in
1 It 4 in
None
None
3 NE=>W 6
Metal Low-E Single Yes
0.63 0.25
N
16.2 ft'
1 ft 0 in
1 ft 4 in
None
None
4 SW=>E 7
Metal Low-E Single Yes
0.63 0.25
N
39.8 ft'
1 ft 0 in
1 It 4 in
None
None
5 NW=>S 8
Metal Low-E Single Yes
0.65 0.21
N
40.0 ft'
8 It 0 in
1 It 4 in
None
None
6 NE=>W 13
Metal Low-E Single Yes
0.63 0.25
N
16.2 ft'
1 It 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 806 ft' 806 ft'
26 It
8 ft
11
INFILTRATION
# Scope Method SLA CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000356 1636.1 89.82
168.92
.2578
7
11/19/2018 2:39 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump/
Split
HSPF:8.5
34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1
Central Unit/
Split
SEER: 15 34.8 kBtu/hr cfm
0.86
1
sys#1
HOT WATER SYSTEM
#
System Type
SubType
Location
EF Cap Use
SetPnt
Conservation
1
Electric
None
Garage
0.97 40 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cart
# Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ft2
DUCTS
_ /
—Supply—
—Return—
Air
CFM 25
CFM25
HVAC#
V #
Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
ON
RLF
Heat Cool
1
Attic
6 250 ft'
Attic
75 ft' Default Leakage
Attic
(Default)
(Default)
1 1
TEMPERATURES
Programable Thermostat:
Crreiling Fans:Cool*!ng
Vent ng
,Y
Jan
Jan Feb
(Feb(X��Mar
Mar
Apr
I�
May �x� Jun [ ] Jul
[ ]
ri Aug
[ ]
[X] Sep
j j
L
X
H Dec
l J
[ ]
[X]
[
Jun [ 1 Jul
[ 1 Aug
[ ]Sep
lXl
Occtt
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8
9
10
11
12
Cooling (VVD)
AM
78
78 78
78 78 78
78
78
80
80
80
80
PM
80
80 78
78 78 78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78 78
78 78 78
78
78
78
78
78
78
PM
78
78 78
78 78 78
78
78
78
78
78
78
Heating (WD)
AM
66
66 66
66 66 68
68
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
66
66
Heating (WEH)
AM
66
66 66
66 66 68
68
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
66
66
11/19/2018 2:39 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 6
CORM R405-2017
INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 lbs/sq.ft.
0 ft2
0 ft
0.3
MASTER BEDROO
Default(8 lbs/sq.ft.
ft2
ft
0.3
WIC
Default(8 lbs/sq.ft.
ft2
ft
0.3
MASTER BATH
Default(8 lbs/sq.ft.
ft2
ft
0.3
M. BATH
• Default(8 lbs/sq.ft.
ft2
ft
0.3
LAUDRY
Default(8 lbs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8 lbs/sq.ft.
ft2
ft
0.3
DINING/GREAT R
Default(8 lbs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(S lbs/sq.ft.
ft2
ft
0.3
BATH
Default(8 lbs/sq.ft.
ft2
ft
0.3
HALL
Default(8 lbs/sq.ft.
ft2
ft
0.3
FOYER
Default(8 lbs/sq.ft.
ft2
ft
0.3
BEDROOM 3
Name: Test Rater Signature:
Rating Compant: Test Rater Date:
11/19/2018 2:39 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 6 of 6
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT
' Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Y
Owner: Jurisdiction:
w
• Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
/soffit
The insulation in an dropped ceiling/soffit
Y 9
the insulation and any gaps in the air barrier shall be sealed.
ai
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
Bs.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be airtight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
I
Caulking or other adhesive sealants shall not be used to fill voids
between fire sprinkler cover plates and walls or ceilinas
a. in auunion, inspection or iog wans snail De in accordance wan the provisions or IGc-auu.
11/19/2018 2:40 PM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R 6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R 6.0
c) AHU location Attic/Attic
3. No. of units (if multiple -family)
3. 1
4. Number of bedrooms
4. 3
13. Cooling system: Capacity 34.8
a) Split system SEER 15.0
5. Is this a worst case? (yes/no)
5. Yes
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6. 1753
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a. 0.635
b) Solar Heat Gain Coefficient (SHGC)
7b. 0.239
14. Heating system: Capacity 34.8
c) Area
7c. 151.4
a) Split system heat pump HSPF 8.5
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a. NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b. NA
e) Gas furnace, LPG AFUE
0 Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a. 0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF 0.97
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
1 OA2. 4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
1061. 11.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a. 30.0
b) Cross ventilation No
b) Single assembly
11b.
c) Whole house fan No
c) Knee walls/skylight walls
11 c.
d) Multizone cooling credit
d) Radiant barrier installed
11d. No
e) Multizone heating credit
0 Programmable thermostat Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
-1 certify that this home has complied with the
Florida Building Code, Energy
Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before
final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature:
Date:
Address of New Home: THE WINDSOR �3�158 City/FL Zip: FT. PIERCE. FL
11A 912018 2:40:00 PM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
+ wrightsoft®
Project Summary Date:
Entire House By:
QUICK CALCS, INC.
SCANNED
For.
WYNNE DEVELOPMENT
THE WINDSOR, FT
BY
PIERCE,
FL
St. Lucie Countv
Notes:
Design Information
Weather. Fort Pierce, FL, US
Winter Design Conditions
Summer Design
Conditions
Outside db
42 OF
Outside db
90 OF
Inside db
70 OF
Inside db
75 OF
Design TO
28 OF
Design TD
15 OF
Daily range
L
Relative humidity
50 %
Moisture. difference
61 gdlb
Heating Summary
Sensible Cooling Equipment Load Sizing
Structure
18467 Btuh
Structure
17655 Btuh
Ducts
6190 Btuh
Ducts
9340 Btuh
Central vent (0 cfm)
0 Btuh
Central vent (0 cfm)
0 Btuh
none
Humidification
0 Btuh
Blowner1e)
0 Btuh
Piping
0 Btuh
Equipment load
24657 Btuh
Use manufacturer's data
n
Rate/swingg multipplier
0.95
Infiltration
Equipmenfsensibleload
25645 Btuh
Method
Simplified
Latent Cooling Equipment Load Sizing
Construction quality
Average
Fireplaces
0
Structure
2453 Btuh
Central
-0
vent (0 cfm)
Btuh
Area
Heatingg Coolingg
(none)
(ft2)
1753 1753
Equipment latent load
50Q7 Btuh
Volume (W)
14741 14741
Airchanges/hour
0.38 0.20
Equipment total load
30652 Btuh
Equiv. AVF (cfm)
93 49
Req. total capacity at 0.70 SHR
3.1 ton
Heating Equipment Summary Cooling Equipment Summary
Make Cartier
Make Cartier
Trade CARRIER AIR CONDITIONING
Trade CARRIERAIR CONDITIONING
Model 25HBC536A'030
Cond 25HBC536A•030
AHRI ref 7914585
Coil FX4DN(B,F)037
AHRI ref 79145M
Efficiency
8.5 HSPF
Efficiency 12.0 EER,
15 SEER
Heating input
Sensible cooling
24360
Btuh
Heating output
34600 Btuh @ 470F
Latent cooling
10440
Btuh
Temperature rise
27 OF
Total cooling
34800
Btuh
Actual airflow
1160 cfm
Actual airflow
1160
cfm
Air flow factor
0.047 cfm/Btuh
Air flow factor
0.043
cfm/Btuh
Static pressure
0.50 in H2O
Static pressure
0.50
in H2O
Space thermostat
Load sensible heat ratio
0.84
Capacity balance point = 34 OF
Backup:
Input = 7 kW, Output = 23009 Btuh, 100 AFUE
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
WrIghYSOft' RightSPage 1
ufteO Universal 201717.0.14 RSUD8101 2017-Apr-1a 1
... k Calcs{Dmc ntslWYMJE-TFEWIND50R-REVISED.mp Calc=MJ8 Front Dwrkces: N Pagel
wrightsotr Right-J® Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By:
317 ST. LUCIE LK, FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-46M796 Email: OUICKCALCS @ AOL.COM
1
Room name
Entire House
MASTER BEDROOM
2
=ad wall
153.0 It
45.0 ft
3
Room height
8.4 ft d
8.0 ft heat/cool
4
Room dimensions
1.0 x 280.0 It
5
Room area
1763.0 ft-
280.0 ft'
Ty
Constmction
U-value
Or
HTM
Area (ft9
Load
Area
number
(BtuhlW17)
(BtuNft2)
or perimeter (ft)
(Btuh)
or pedmet)er (ft)
(Bt�uh
Heat
Cool
Gross
NIP/S
Heat
Cool
Gross
WP/S
Heat
Cool
6
13AAocs
0143
ne
400
2.55
498
448
1795
1141
192
.. 192
769
489
-�1Acl= "
'.1 270
no
,:35.56
, 70.43
- . 7
- •0
" 2A7
,-�488
0:
0
... 0
-.'-0
:1Ao1om:-.
`7270
ne
•_3556
'
✓ 70.43--.
16,
0'
` 581
.1151
0
'0-!
J 0
:-'�0
1Aclorn
1.270
no,
..35.56
45.24
' 16
0
•:. 681
739
.0
: 0
. .0
_. �' 0
11
l4!
13A-4ocs
0.143
se
4.00
2.55
64
41
165
105
-0
0
0
0
�-D
1100
'13A4acs
0.390
se
1092
11.31
23
23
248
257
0
0
0
0
W .�
-. -
..-0.143
Sw
.. 400
255
.437
;- .396
AW
,=.1007
Be
� . 56
: 224:
'._-043
. LL .GZ
4AS2onn
0.770
'-sw
,2156
.''2753
41
`:. 45
•893
_,
'1140
-. 0
. 0
i 0
.'.0
Vjl
13A4ocs
0.143
nw
4.00
2.55
290
217
867
551
112
79
318
202
1Acl m
1.270
nw
35.56
45.24
33
0
1162
1478
33
0
1162
1478
II---�f'
"'-.:12C-Osvw
4A5-2wnd
0.770
pw
21.65
36.90
41
0
880
1505
0
0
0
0
P:
0.091-=-
,12.55--
1:28-
308-.
-308
"-784
•395
. .--0-:
_0
+0--
C
16A-30md
0.032
-
0.90
232
1753
1753
1571
4D67
280
280
.:'
251
.O
650
F` - .;
22A-tpl. ..
. . 0.989
-.
27.69
`, . 0.00...
1753...
--153
4237
` .0
-. 280
45
, 1246..I:
0
6
c)AED emursion
1360
600
Emalope loss/gain
16594
15M
3970
3561
12
a) Infiltration
2873
810
8D9
228
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
2
460
0
0
Appliances/other
1000
0
-
Subtotal (lines 6 to 13)
18467
17655
4779
3789
Less eMernal load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
18467
17655
4779
3789
15
Duct loads
34%
53%
6190
9340
34%
53%
1602
2005
Total room load
24657
26M
6380
5794
Air required(cfm)
116D
1160
300
249
.�A ' Wrightsoft- RlghtSulte® Universal 2017 17.0.14 RSUG8101
... k CelcslDocuments%WYNJE-THEWINDSOR-REVISED.wp Calc=MJ8 Front Doorfaces:
2017-Apr-10 17:19:28
Page 1
wrightsoft• RiOW@ Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By-
317 ST. LUCIE LM, FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: QUCKCALCS a OL.COM
1
Room name
WIC
M. BATH
2
Elrposed wall
0 ft
7.0 ft
3
Room height
8.0 It heaVocol
8.0 ft heal/cool
4
Room dimensions
7.0 x 9.0 ft
1.0 x 61.0 ft
6
Room area
63.0 ft'
61.0 ft'
Ty
Consttucticn
U-value
Or
'HTM
Area
Load
Area
Load
numlw
(Btuhfftk•
(Btuh1ft-)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
NP/S
Heat
Cool
Gross
WP/S
Halt
Cool
6
13A4ocs
0143
no
400
2.55
0
0
0
0
56
48.
196
125
1Ac1om ..-
1270
ne,
,3556
:.70.43
= 0
0
0
.0
7'
0:
247.488
-1270
no
. -,.35.56
70.43
: 0
0
- - 0
0
..0
, 0.'
0
-.. FO
.
1Ac1om .-
1.270
• no .
35.56
' "45.24
- 6
0
: . 0
: - 0
0
0
0
:. i0
11
VL—D
13A4ocs
0.143
se
4.00
2.55
0
0
0
0
0
0
0
0
11D0
0390
se
1092
11.31
0
0
0
0
0
0
0
0
13A4o6s : - '
' ; 0143
1-SW'.
400
:_, �265
..0
:- 0
=-' . O
S .0
0'
0
.. - . p
':r .. ' ..r0
4A5-2om.'0770
.sw>
•2L56.-',27:53
0-
0
0
'0
-,0'-
0-
0
4)/
13A-0acs
0.143
nw
4,00
255
0
0
0
0
.-.0'
0
0
0
0
IAclm
1.270
my
35.56
45.24
0
0
0
0
0
0
0
0
4AS-2=d.
0.770
nw
21.56
36.90
0
0
0
0
0
0
0
0
P � _
12C-0sW; :'
0091
._+=
.,i'155
1.28
_
:0
.0..
0
- 0
0
"-0`-
$'s
:10
C
16A30md
0.032
-
0.90
232
63
63
58
146
61
61
55
- 142
F i
22A-tpl" •.... ..
6.989
-
27.69'
. C.00.=
:. 63
0
;0
.. ,0
61
. :7
.. 194
:: ..:, 0.
6
c)AEE excursion
_5
-26
Envelope lass/gain
56
141
692
729
12
a) Infiltration
0
0
126
35
b) Roomventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
0
0
Appliances/other
0
0
Subtotal (lines Etc 13)
56'
141
817
764
Less euemal load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
56
141
817
764
15
Duct loads
34%
53%
19
75
34%
53'/0
274
404
Total roam load
75
216
1091
1168
Alrrequired(cfm)
4
9
51
50
� A '} wrightsoft• RlghtSuite@ Universal 2017 17.0.14 RSU08101
... k CalcslDocuments%WYMJE-THEWINDSOR-REVISED.mp Calc=MJB Front Doorfaces: N
2017-Apr-10 17:19:28
Page 2
wrightsof . Right-M Worksheet Job:
Entire House Date:
QUICK CALCS, INC: By.
317 ST. LUCIE I-M, FT. PIERCE, FL 34946 Phone: 772-466-0799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM
1
Room name
LAUDRY
BEDROOM
2
E)posed wall
0 R
12.0 ft
3
Room height
8.0 ft heat/cool
8.0 It heattcool
4
Room dimensions
6.0 x 6.0 It
15.0 x 120 It
5
Room area
36.0 ft-
180.0 W
Ty
Combuction
U-%slue
Or
HTM
Ana (to
Load
Area (fl')
Load
number
(Btuh/fti*F)
(Btuh/ft')
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
WP/S
Heat
Cool
Gross
WP/S
Heat
Cool
8
13A4ccs
0143
ne
400
255
0
0
0
0
96
SO
- 319
'203
_1Ao1om
�1270
ne
. 3556
; ' 70.43
=. 0
0
0
.0
. - 0'+
0
"' 0
-'.;0
'1Aa1om
.1270
ne
, -3556
. 70.43:
0
0
0'
'-0
.16
0
. - 581
- "1751
_1Aatom,_
.1.270
no
r35.56
45.24
- 0
0
0
0
0
0.
0
'::0
11
Vy
13A-flocs
0.143
se
4.00
255
0
0
0
0
0
0
.
0
0
�D
11D0
0390
se
10.92
11.31
0
0
0
0
0
0
0
0
-_`.,
0.143
•sw
:400
.; .. 265
0-
0.
0
; 0.'..
0,.
"•0
;. 0
-0
4A`r-2an
;o770
.sw.
. 21.56
- 27.53.
0...
0
0
A
,
0
-0
t o
, '-A
1�1
13A-0as
0.143
nw
4.00
2.55
0
0
0
0
0
0
0
0
1Ac1om
1.270
nw
35.56
45.24
0
0
0
0
0
0
0
0
4A5-2omd
0.770
nw
21.56
36.90
0
0
0
0
0
0
0
0
P ;.
Im-0Sw' -.
_'..0.091
`..:
`255-.
'1f28
`.. .0
.0'
0.
0+'
0.'
'0.'
.0r
0
C
16A30md
0.032
-
0.90
232
36
36
32
84
ISO
16C
161
_"
418
F :..,:
224-tpl 1
0.989
- -.
27.69
. . 0.00
36
0
. - .0
-.0
:. 180
. • -12
.: 332
•>. 1, " , -0
6
c)AED excursion
.3
S0
FrnrJope loss/gain
32
81
1394
1711
12
a) Infiltration
0
0
216
61
b) Roomvemilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
0
0
Appliances/other
0
0
Subtotal pines 6 to 13)
32
81
1609
1772
Less exdemal load
0
0
0
0
Less transfer
0
0
0
0
RedisMhution
6
14
6
14
14
Subtotal
38
95
1615
1786
15
Duct loads
34%
53%
13
50
34%
53%
541
945
Total room load
51
145
2156
2730
Air required(ofm)
2
8
101
117
h -FfF wrighYSofL- Right-Suhe@ Universal 201717.0.14 RSU08101
... k CalcslDocumntslWYNNE-THEWINDSOR-REVISED.wp Calc=MJB Front Doorfaces: N
2017-Apr-10 17:19:28
Page 3
wrightsofr Right-J® Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By:
317 ST. LUCIE LM, FT. PIERCE, FL 34946 Phone: 772-466-6799 Faz 77246"796 Email: OUICKCALCS@AOLCOM
1
Room name
DINING/GREAT ROOM
WrCHEN
2
@gored wall
50.0 ft
11.0 ft
3
Room height
8.9 ft heaticool
8.9 ft heat/cool
4
Room dimensions
1.0 x 588.0 If
19.0 x 11.0 ft
5
Roam area
5860 fP
209.0 ft-
Ty
Constmctim
U-value
Or
HTM
Area
Load
Load
number
I
(BiulvilmF)
(BtulYft')
or perimeter (ft)
( )
a�perimeter (ft)
(Btuh)
Heat
Cool
Gross
NIP/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
ty
s
0143
ne
456
255
0
0
0
0
0
p
0
1Acl
-0A;olm
- 1270
rle
-35.56
.70.43
' - 0
0
D
0
0
0
0
_0
'0
1A�icm
`1270-ne'35.56
=.70.430..
0'
'.0.
0
'0.,
`0
0"
`0
'1Aa1an -
1.270
%ne
-3556
45.24
0
o-
0
.. 0
0
- ,0
0
+0
11
Vy
13A4ocs
0.143
se
4.00
255
0
0
0
0
0
0
0
0
-D
11D0
0390
se
to.
D 92
11.31
0
0
0
0
0
0
0
0
13A4acs`_: = _
`0143
sw'
" 40D
-.,, Z65
267
.226
. - . 903
.: _ 574
�' ...98
:. 96
.. 392
.; :249
_G
4A5-2um:
0.770
.sw:
-21.56
-27.63
41
22
893
'. 1140
o
,.
vIV--�
13A-flocs '
0.143
rnv
4.00
2.55
178
137
549
349
_-.
0
:o
0
0
0
1A-clan
1.270
ma
35.56
45.24
0
0
0
0
0
0
0
0
�-�G
'
4A5-2o nd
0.770
my
21.66
36.90
41
0
880
1505
0
0
0
0
P :::
12C-03w. -
D,091
.-
. " 255
7:28
, •0
. 0
- .- 0
'0
,, ;11
-.:fl0
, ' 28
`..- •-'14
C _ -
16A-30md
0.032
-
D.90
232
588
688
627
1364
209
209
187
485
F-
22*tpl' ...
.. . 0.989
-;
27.69
-. 0.00
.. 588.
50
4385
. 0
209
. 11
': 305
- -i -,0
6
c)AED excursion
1004
-64
Envelope lass/gain
5136
5937
-
1179
818
12
a) Infiltration
1000
282
220
62
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
2
460
0
0
Appliances/other
0
-
low
Subtotal tines Etc 13)
6136
6679
1399
1880
Less edemal load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
6
141
0
0
14
Subtotal
6142
6693
1399
1880
15
Duct loads
34%
53%
2058
3541
34%
53%
469
995
Total roam load
8200
10234
1867
2875
Air required(cfm)
386
=
- 88
124
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
wrilghtsofv
A ...Universal2017 17.RSU08107 2017-Apr-10 17:19:28
k CaIcsl0ocumentslWYNE-THE WINDSOR-REASED.mp Calls = MJB Front poor faces: N Page
i# wrightsoft- Right-JO Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By:
317 ST. LUCIE LR, FT. PIERCE, FL 34946 Phone: 7724666799 Fax 7724666796 Emil; QUICKCALCS@AOL.COM
1
Room name
BATH
HALL
wall
heght
5.0 ft
0 ft
3
Room
8.0 ft heat/ccol
8.0 It heat/cool
4
Room dimensions
10.0 x 5.0 it
SO x 5.0 It
5
Room area
50.0 ft2
25.0 ft2
TY
Construction
WueF
Or
HTM
A rea
Load
Area
Load
number
)
(Btuwft)2
or perimeter ft ()
(etuh)
e
or perimeter ter (ft)
(&uh)
Heat
Cool
Gross
WP/S
Heat
Cool
Gross
WP/S
Heat
Cool
6
13A4=
0.143
ne
400
255
40
40
160
102
0
0'.
0
0
.tAclom:...
1.270
ne
,r'3556
70.43
0
:0
- ,' 0
_0
.. U'.
' 0:'
. 0
_0
;1Ac1om-_
1;270
ne
3556
Y,70.43.
-..0
.' ..0
- 0
'0
; 00
..0
0
;.'0
..
i4Aclom `
- i1:270
_.ne.
, 35.56
.45.24
0
0
0
- 0
-.0
.. •0
. .,
" 0
11
yl
13A-4=
0.143
se
4.OD
255
0
0
0
0
0
0
.
0
0
�D
11130
0.390
se
1092
11.31
0
0
0
0_
0
0
0
0
W
13A4ocs .::
, .'0;143
sw
'4.00
,....255
,. 0
�.. .: 0
°' , . 0
.. ` :
- • ..:"' 0'
0
- 0
,LG'4A5-tom
:. ..
•:0.770
sw
21.56'
'.27.53•
0
'.- 0
0
...0
" 0'
0
0:.
0
.r0
,'' 0
YID--G
13&4ocs
0.143
nw
4.00
265
0
0
0
0
0
0
0
0
1A-clom
1.270
W
35.56
46.24
0
0
0
0
0
0
0
0
I--G
4A5-2omd
0.770
m
21.56
_ 36.90.
0
0
0
0
0
0
0
0
.,
50
.45
•
0
C
126A30mtl
0.03P
0.90
232
50
116
25
2,
22
58
F r
22A-tpL - . ..
a0.989
-
;0..69
- 0.06
- 56
5
-138
- 0
- 25
0
-- 0
--..TO
6
c)AFD excursion
.8
-2
Envelope lass/gain
343
210
22
56
12
a) Infiltration
90
25
0
0
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
0
0
Apptiancestother
0
0
Subtotal (lines 6 to 13)
433
235
22
56
Less mdernal load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
6
14
-22
-%
14
Subtotal
439
249
0
0
15
Duct leads
34%
53%
147
132
34%
53%
0
0
Total reem load
586
381
0
0
Air required(cfm)
28
16
0
0
. A r wrightsoft- Right -Suite® Universal 2017 17.0.14 RSUD8101
...k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.mp Cale =MJ8 Front Door faces: N
2017-Apr-10 17:19:28
Page 5
wrightsoft- RighW@ Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By:
317 ST. LUCIE LN, FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 7724664i796 Email: DUICKCALCS@AOL.COM
1
Room name
FOYER
BEDROOMS
2
F1ylosed wall
9.0 R
14.0 it
3
Room height
8.0 it heat/cool
8.0 it heat/cool
4
Room dimensions
1.0 x 920 it
13.0 x 13.0 it
5
Room area
920 R'
169.0 iN
Ty
ConsWction
U-value
Or
HTM
Area
Am
number
(Btuh/WF)
(Btuh/Rq
or perimeter (ft)
(Btuhuh)
or perimeter (it)
(Btuh)
Heat
Cool
Gross
WP/S
Heat
Cool
Gross
WP/S
Heat
Cool
6
13A4ocs
-
0.143
no
400
255
0
0
0
0
104
88
351
223
1Ac1om
.1.270.
ne
3558
70.43
0.
0
0,
0
0'
0
- 0
0
.
tAclam:.:
-ilAclonn
1.270
ne.
3556
. 70.43
- 0
0
', 0
0
_-
- .00
."
0.:
0
;
1.270
no
: 3556
- .-.45.24
0
.o
10
, 0
- 16
0'.
681
�739
11
yl
�D
13A4=
0.143
se
4.00
255
64
41
165
1D5
0
0
0
0
11130
0.390
se
'sw,','r0.00
1092
11.31
23
23
248
257
0
0
0
0
4. .
�'4AS2am,--
13A4ocs -
s: 0.143
'.. 255
.. .,-8
.. '8=
32
:.' :20'
..8
.8�.
32.--.
".20
.
`.0.770
_sw'
21.56
'.`27.53'
- 0.
0'
0
. 0;.
'0
.0'-
.: 0
;0
13A4ocs
0.143
my
4.00
255
0
0
0
0
0
0
0
. ..
0
I--G
IA-clom
1.270
nw
36.56
45.24
0
0
0
0
0
0
0
0
4A5-2ama
0.770
my
21.56
36.90
0
0
0
0
0
0
0
0
12C-0sw, '' _
-0.091
...255
' A.28
. ,,88
... 88
'224
113
- ... 104
265
C
16A30md
0.032
-
0.90
232
92
92
82
213
169
169
151
,'.'-•:133-
392
22A-tpl='
0.989
- -'
27.69
. 0.00
- 92
9
- 249
.0
-169
' 14
: 388
'- <-.0
6
c)AM excursion
-25
-52
Envelope loss/gain
1002
664
1768
1456
12
a) Infiltration
162
46
252
71
b) Room ventilation
0
0
0
0
13
internal gains: Occupants Q 230
0
0
0
0
Appliancesfother
0
0
Subtotal (lines 6 to 13)
1163
730
2020
1527
Less wdemal load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
1163
730
2020
1627
15 1
Duct loads
34%
531
390
3861
345/6
531/
677
808
Total mom load
1553
1116
2697
697
2335
Air required(cfm)
73
48
100
A wrightsoTt• RlghtSuite® Universal 2017 17.0.14 RSU08101
... k Calcs\Documents%WYME-THEWINDSOR-REVISED.mp Calc=MJ8 Front Doorlaces:
2017-Apt-10 17:19.28
Page 6
Duct System Summary -�- wrightsoit° y Job: Date:
Entire House By:
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34M Phone: 772-46"799 Fax 77246"796 Emil; OUICKCALCSQAOLCOM
For. WYNNE DEVELOPMENT
THE WINDSOR, FT. PIERCE, FL
External static pressure
Pressurelosses
Available static pressure
Supply [,return available pressure
Lowest friction rate
Actual airflow
Total effective length (TEL)
Heating
0.50
in H2O
0
in H2O
0.50
in H2O
0.250 / 0.250
in H2O
0.273
in/100ft
1160
cfm
11-M
Cooling
0.50
in H2O
0
in H2O
0.50
in H2O
0.250 / 0.250
in H2O
0.273
in/100ft
1160
cfm
Name
Design
(Btuh)
Htg
(cfm)
Clg
(cfm)
Design
FIR
Diann
(In)
H x W
(In)
Duct
Mati
Actual
Ln (fit)
Ftg.Egv
Ln (ft)
Trunk
BATH
IT 586
28
16
0.372
4.0
OxO
VIFx
19.5
115.0
st1
BEDROOM 2
C 2730
101
117
0.384
7.0
OxO
VIFx
15.0
115.0
st1-
BEDROOM 3
h 2697
127
100
0.353
6.0
OxO
VIFx
26.8
115.0
all
DININGIGREAT ROOM
C 3411
129
147
0.292
7.0
OX0
VIFx
36.5
135.0
st2
DININGIGREAT ROOM-B
C 3411
129
147
0.371
7.0
OxO
VIFx
19.9
115.0
at1-
DINING/GREATROOM
.0 3411
129
147
0.278
7.0
OxO
VIFx
44.9
135.0
st2
FOYER
h 1553
73
48
0.490
4.0
NO
VIFx
7.0
95.0
KITCHEN
C 2875
88
124
0.366-
6.0
OxO
VIFx
21.8
115.0
st1
LAUDRY
c 145
2
6
0.371
4.0
OxO
VIFx
19.9
115.0
st1
M. BATH
h 1091
51
50
0.282
6.0
OxO
VIFx
42.3
135.6
st2
MASTER BEDROOM
h 3190
150
124
0.273
6.0
OxO
VIFx
48.4
135.0
61t2
MASTER BEDROOM -A
h 3190
150
124
0.284
6.0
0x0
VIFx
40.9
135.0
st2
WIC
c 216
4
9
0.292
4.0
Ox0
VIFx
36.0
135.0
st2
Trunk
Htg
Clg
Design
Veloc
Diann.
H x W
Duct
Name
Type
(cfm)
(Cfm)
FIR
(fpm)
(In)
(In)
Material
Trunk
st2
PeakAVF
612
602'
0.273
780
12.0
0 x 0
VinlFlx
st1
all
Peak AVF
1087
1112
0.273
796
16.0
0 x 0
VinlFlx
t wri htsofY• 2017-Apr-101T.19:29
9 RightSuite® Universal 2017 17.0.14 RSU08101 Page 1
...k CalcslDwumnts\WYNNE-TFEWINDSOR-REVISED.rup Calc=MJB FroMDoorfaces: N
Name
Grille
Size (in)
Htg
(cfm)
Clg
(cfm)
TEL
(ft)
Design
FR
Veloc
(fpm)
Diam
(in)
H x W
(in)
Stud/Joist
Opening (in)
Duct
Matl
Trunk
rb1
Ox0
1160
1160
0
0
0
0
Ox 0
1
VIFx
-tiWrl htsOtt- 2017-Apr-10 17:19:29
9 RightSuite® Universal 2017 17.0.14 RSU08101 Page 2
...It CalcsIDOcumentsIVNW E-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N