Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Departmbnt of Business and Professional Regulation - Residential Performance Method Name: N/YNNE TF1E GRAND CARLTOti IMPACT Builder Name: NE BUILDING OPR SC•®NlN6fbr Street \�J` - Permit Officer ST NUCIE COUNTY City, State, Zip: FT. PIEEROEE ,,�F�L`1, Permit Number: v7 Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY St._ Lucie County Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1442.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ft' b. Frame - Wood, Adjacent R=11.0 192.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 5. Is this a worst case? Yes 10. Ceiling Types (1446.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1446.00 ft2 6. Conditioned floor area above grade (ft2) 1446 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft' 7. Windows(141.3 sqft.) Description Area a. Sup: Attic, Rat: Attic, AH: Attic 6 250 a. U-Factor. Sgl, U=0.54 101.25 ft2 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.55 40.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.832 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems 8. Floor Types (1445.5 sqft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1445.50 ft2 b. Conservation features EF: 0.970 b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.098 Total Proposed Modified Loads: 47.35 PASS Total Baseline Loads: 48.09 I hereby certify that the plans and specifications covered by Review of the plans and STgl�t this calculation are in compliance with the Florida Energy specifications covered by this OF'C86 Code. calculation indicates compliance with the Florida Energy Code. PREPARED Y: Before construction is completed q O DATE: - this building will be inspected for ft compliance with Section 553.908 , I hereby certify that this building, as designed, is in compliance Florida Statutes. 6� with the Florida Energy Code. p 11,E OWNER/ OWNER/AGE BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 11/18/2018 1:09 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Tifle: WYNNE THE GRAND CARL Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1446 Lot # Owner Name: WYNNE BUILDING CROP Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE BUILDING COPR. Rotate Angle: 180 Street: Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST. LUCIE COUNTY Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE _ / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1446 11568 SPACES . Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 301 2408 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M.BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0 301 ft' _-_ 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 ft' ___ 0 1 0 3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0 56 ft' ___ 0 1 0 4 Slab -On -Grade Edge Insulatio KITCHEN t ft 0 192 ft' — 0 1 0 5 Slab -On -Grade Edge Insulatio BATH 5 ft 0 45 ft' 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 It 0 203.5 ft' ___ 0 1 0 7 Slab -On -Grade Edge Insulatio ENTRY 7 ft 0 55 ft — 0 1 0 11/18/2018 1:09 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST RFPART FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft 0 42 ft' __ 0 1 0 9SIab-On-Grade Edge Insulatio GREAT/DINING 46 ft 0 488 ft' __ 0 1 0 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1524 ft' 240 ft' Light 0.6 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1446 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 301 ft' 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft' 0.1 Wood 3 Under Attic (Vented) M. BATH 30 Blown 56 ft' 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 192 ft' 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 ft' 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 204 ft' 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 55 ftz 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft' 0.1 Wood 9 Under Attic(Vented) GREAT/DINING 30 Blown 488 ft' 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 0 1 NE=>SW Exterior Concrete Block - Ext InS®EDROOM 4.1 10 0 8 0 80.0 ft° 0 0 0.6 0 2 SW=>NE Exterior Concrete Block - Ext InsfBEDROOM 4.1 28 0 8 0 224.0 ft' 0 0 0.6 0 3 NW=>SE Exterior Concrete Block - Ext Ins®EDROOM 4.1 14 0 8 0 112.0 ft' 0 0 0.6 0 4 SW=>NE Exterior Concrete Block - Ext InsuM. BATH 4.1 8 0 8 0 64.0 ft' 0 0 0.6 0 _ 5 NE=>SW Exterior Concrete Block - Ext Insul BATH 4.1 5 0 8 0 40.0 ft' 0 0 0.6 0 6 NE=>SW Exterior Concrete Block - Ext InfiffDROOM 2 4.1 16 0 8 0 128.0 ft' 0 0 0.6 0 7 SE=>NW Exterior Concrete Block - Ext IndIffDROOM 2 4.1 10 0 8 0 80.0 ft' 0 0 0.6 0 8 S=>N Exterior Concrete Block - Ext InQEDROOM 2 4.1 4 3 8 0 34.0 ft' 0 0 0.6 0 9 SW=>NE Exterior Concrete Block - Ext InRIEDROOM 2 4.1 2 0 8 0 16.0 ft- 0 0 0.6 0 10 SE=>NW Exterior Concrete Block - Ext Insul ENTRY 4.1 6 0 8 0 48.0 ft- 0 0 0.6 0 _ 11 SW=>NE Exterior Concrete Block - Ext Insul ENTRY 4.1 1 0 8 0 8.0 ft' 0 0 0.6 0 _12 SW=>NE Exterior Concrete Block -Ext lnsdtAUNDRY 4.1 6 0 8 0 48.0 ft- 0 0 0.6 0 13 NE=>SW Exterior Concrete Block - Ext InsGREAT/DINI 4.1 26 0 8 0 208.0 ft2 0 0 0.6 0 14 NW=>SE Exterior Concrete Block - Ext Ins REAT/DINI 4.1 20 0 8 0 160.0 ft' 0 0 0.6 0 15 N=>S Garage Frame - Wood KITCHEN 11 24 8 192.0 ft' 0.23 0.6 0 11/18/2018 1:09 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT DOORS # Omt Door Type Space Storms U-Value Width Ft In Height Ft In Area 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6 ft' WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall V # Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening _ 1 NW=>SE 3 Metal _ 2 SW=>NE 4 Metal 3 SE=>NW 7 Metal 4 NE=>SW13 Metal 5 NW=>SE14 Metal Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Yes Yes Yes Yes Yes 0.54 0.25 N 32.9 ft' 1 ft 0 in 1 ft 4 in 0.54 0.25 N 6.9 ft' 1 ft 0 in 1 ft 4 in 0.54 0.25 N 24.0 ft' 6 ft 0 in 1 ft 4 in 0.54 0.25 N 37.5 ft' 1 ft 0 in 1 ft 4 in 0.55 0.25 N 40.0 ft' 8 ft 0 in 1 ft 4 in Drapes/blinds None None None Drapes/blinds Exterior 5 None None None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 315 ft' 315 ft' 24ft 8ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 • Wholehouse Proposed ACH(50) .000356 1349.6 74.09 139.34 .2578 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 34.8 kBtulhr drn 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft' 11/18/2018 1:09 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT DUCTS — Supply —, — Return — Air CFM 25 CFM25 HVAC # V # Location ' R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 250 ft' Attic 65 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programabl[e Ceiling Fans: jThermostart:,]Y Heating [X] Jan Feb ]] IX] Mar Jun [[ [X� Jul f[` j]] Aug [X� [ ] Sep [ ] [rX'] L J Nov Dec rid, Venting [[ ])Jan [ 1 Feb l J IIX1l Mar Apr [ MaM:yy Jun [[ Jul [ 1 Aug lXl [ 1 Sep lxl Oct [X] Nov [ ] Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft' Oft 0.3 BEDROOM - Default(8 lbs/sq.ft. f, ft 0.3 WIC Default(8 Ibs/sq.ft. ft, ft 0.3 M. BATH Default(8 lbs/sq.ft. ft' ft 0.3 KITCHEN Default(8 lbs/sq.ft. ft' ft 0.3 BATH Default(8 Ibs/sq.ft. ft' ft 0.3 BEDROOM 2 Default(8 lbs/sq.ft. ft' ft 0.3 ENTRY Default(8 lbs/sq.ft. ft' ft 0.3 LAUNDRY Default(8 lbs/s.ft. ft' ft 0.3 GREAT/DINING Name: Test Rater Rating Compant: Test Rater fLei --- — D. r 11/1812018 1:09 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 6 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR, BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE GRAND CARLTON IMPACT Builder Name: WYNNE BUILDING COPR. Street: Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY w Design Location: FL, Fort Pierce x=i COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air bander shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in an dropped ed ceiling/soffit Y the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids I;ppuun �re png@klqr cover plates mpo Walls or pilings, a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 11 /1812018 1:09 PM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 -2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the Energy Performance Index, the more efficient the home 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity 34.8 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER c) Ground/water source SEERICOP 6. Conditioned floor area (sq. ft.) 6. 1446 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.543 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250 14. Heating system: Capacity 34.8 c) Area 7c. 141.3 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE 0 Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.97 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 0 Heat recovery unit HeatRec0/o B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B1. 11.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit 0 Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. +\ G Builder Signature: Date: 5 Address of New Homer City/FL Zip: FUERGE. FL:�C-A_. � % .21 11/18/2018 1:09:43 PM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 wrightsoft® Project SummaryJob: Enure House Da QUICK CALCS, INC. 317 ST. LUCIE.LN., FT. PIERCE, FL 34946 Phone: 772-46"799 Fax 772-46"796 Emil: OUICKCALCS@AOLCOM For. THE GRAND CARLTON BY WYNNE DEVELOPMENT, FT. PIERCE, FL St. LudeCOunty Notes: � Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Structure 17848 Btuh Ducts 5654 Btuh Central vent (0 ofm) 0 Btuh (none) Humidification 0 Btuh Pi in Equipmentload 23503 Btuh Infiltration Method Simplified Construction quality Average Fireplaces 0 Area ft He 1446 Cool1446 Volume (ft3) 12511 12511 Air changes/hour 0.45 0.23 Equiv.AVF (cfm) 94 48 Heating Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Model 25HBC536MO30 ' AHRI ref 7914585 8.5 HSPF 34600 Btuh @ 47°F 27 OF 1160 cfm 0.049 cfm/Btuh 0.50 in H2O point = 32 OF Backup: Input = 7 kW, Output = 23009 Btuh, 100 AFUE Sensible.Cooling Equipment Load Sizing Structure 17520 Btuh Ducts 8536 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Ratelswinqq multipplier Equ10melTfsensibleload 0.95 24753 Btuh Latent Cooling Equipment Load Sizing Structure 3203 Btuh Ducts 2318 Btuh Central vent (0 cfm) 0, Btuh (none)' Equipment latent load 5521 Btuh Equipment total load 30274 Btuh Req. total capacity at 0.70 SHR 2.9 ton Cooling Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Cond 25HBC536A'030 Coil FX4DN(B,F)037 AHRI ref ' 7914585' Efficiency 12.0 EER, 15 SEER Sensible cooling 24360 Btuh Latent cooling 10440 Btuh Total cooling 34800 Btuh Actual airflow 1160 cfm Airflow factor 0.045 cfm/Btuh Static pressure 0.50 in H2O Loadsensible heat ratio 0.83 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsofr RightSuite® Unioarsal 201717.0.14 RSU08101 2017-Apr-11 09:29:38 �'Cp ...ulck CalostDocumentstTHE GRAND CARLTON-1446.rup Calc = MA Front Door faces: N Page 1 • - wrightsoft Right-M Worksheet Job: Entire House Date: ey. QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-46"799 Fax 772-466.6796 Email: QUICKCALCS AOL.COM 1 Room name Entire House BEDROOM 2 E>,}posed wall 156.2 If 49.0 ft 3 Room height 8.7 R d 8.0 If headc0ol 4 Room dimensions 1.0 x 297.0 it 5 Room area 1445.5 ft2 297.0 ft2 Ty Construction U-value Or HTM Area (toLoad Area Load number (BtulVfti°F (Btuwft2) or perimeter (ft) (Btuh) or perimeter. (ft) (Bluth) Heat I Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 W 13A+kcs '. �4Ab2an---t. .0143 :.0 4.00.: ' 255 503 ;M' '1862 - :1184 . '72' 72 ' . , 288 183 L=' .0770 ".n: 21:56 19.31 r38'.' 0� ;`815 '- ..`730' , "':0 0�'' 0. 1=_.0 13A4ocs 0.143 a 4.00 255 128 83 333 - 212 0 0 0 0 1Aa1om 1.270 a 35.56 87.29 24 2 848 2082 0 0 0 0 11 II--DDDD 11DO 0.39D a 10.92 11.31 21 21 229 238 0 0 0 0 AAA-0oos - . .,0.143 i:se 4.00 -.255 • ..34 . .. 34. -, 136 .-" 86 0 '. 0 > 0 -.--0 W �C 13A ccs 0.143 s 4.00 255 360 353 1414 899 216 . 216 865 1Acicm 1.270 s 3556 34.77 7 7 247 241 0 0 0 0 13446cs 0:143 W .. '�400 266 310 237 - 949 , 603 .704 72. 288 '183 1Ac1om ', . T.270 w; 3556 5521 .32 :. 21140 - 1770 -32= 2 1140 1770 _ 4A5-tom .. ._ ;0.770 . w.. '21.56 "- 19:31 .-, 41 . - 41..• -1880 ` - -788 - =0 0:• .. .,0 » : -0 P 12C-0sw 0.091 - 2.55 1.28- 192 192 489 246 0 0 0 - --0 ':.16A30md- 0.032 �.., .. , 0.90 -232'" 1446, . 1446 i, -1295 ; -,3354 .:.-. "297 .: 297 '266: .... 699 F 22A-tpl 0.989 27.69 0.00 1446 156 4325 0 297 49 1367 0 6 c)AED eurrrslon 918 827 Envelope loss/gain 14961 13349 4204 40M 12 a) Infiltration 2887 791 848 232 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 6 1380 3 690 Appliances/other 2Dp0 0 Subtotal(lines 6to 13) 17848 17520 SOSi 4925 Less eMerml load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 17848 17520 5053 4925 15 Duct loads 32% 49% 56FA 8536 32% 49-4 1601 24M Total room two 21160 Air required(cfm) 1 W3 3028 326 A -FP- wrightsof - RIgMSuitelil Universal 2017 17.0.14 RSU08101 ...uick CaIcs1DGCam6ms\THE GRAND CARLTON-1446.mp Colo = MJ6 Front Door faces: 2017-Apr-11 09:29:38 Page 1 wrightsoft Right-JO Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-4665799 Fax 772-466-6796 Emil: OUICKCALCS@gOL.COM 1 Room name WIC KITCHEN hwall p ft O ft 3 Room height 8.0 ft healfccol 8.0 ft heat/cod 4 Roan dmensions 6.0 x 9.0 ft 1.0 x 172.0 ft 5 Room area 54.0 ft2 1720 ft' TY Construction U-value Or HTM Area (ft2) Load Area (ft� Load number I (Btutdit--F) (BtuWftj or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)- Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 ty- t--G ;13A4ocs .. . , :'0143 n ' . 4.00 Z55 -.. 0 -- -.0 ` 0 : ':-0 0 + :0 .. o -' `. i 0 :4AS2om '..` .- .' _0.770 - n 21M 19:31 0 `.. .0 :. - 0 : :0 9 0 " 0 0 .:0 VI,J---G 13A-4ccs 0.143 a 4.00 255 0 ..0 0 0 0 0 .: 0 0 1Ac1cm 1.270 a 35.56 8729 0 0 0 0 0 0 0 0 11 I--D 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 W" -- 13A4ccS: .. ; . r..-: - 0.143'. se. 4.00 - 255 - _.. 0.. .0,. - ,0 0 0 , 0,_. „ o;..." ..;=0 V�1 13A-4ocs 0.143 s 4.00 2.55 0 0" 0 0 0 0- 0 0 I--(- IA -clan 1270 s 3556 34.77 0 0 0 0 0 0 0 0 13A-0ocs , 0143 w? - 4 00 2.55 0 - 0 0 .. 0_ 0 '`0 -; 0 - 0 G- dAclom " - 1270 w 35,56 55:21 0 _ 0 0' - :0 - 0: 0 0 •0 4A5-2brii 0 vu -. - 21.56 19.31 ' 0 '0 . 1 0 -.0 0 0. , p .. 0 P 121.0sw 0.091 - 255 1.28 0 0 0 0 64 64 163 82 C 16A30mc! 0.032. - 0.90 Z32 64 64 48 125 172 172 154. 399 F 22A-tpl 0.889 - 27.69 0.00 54 0 0 0 172 0 0 0 6 c)AED excursion -9 -170 Envelope loss/gain 48 117 317 311 12 a) Infiltration 0 0 0 0 b) Room venfilatim 0 0 0 0 13 Internal gains: Occupards Q 230 0 0 0 0 Appliances/other p 2000 Subtotal Qirles 6 to 13) 48 117 317 2311 Less edema] load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 14 Subtotal 48 117 317 .0 2311 15 Dud loads 327. 49% 15 57 32% 49% 100 1126 Total room load 64 174 418 3437 Air required (rim) 3 8 1 21 153 ,.1 Calculations approved byACCA to meet all requirements of Manual J 8th Ed 41-- wrlghtsoft- RlghtSuhe® Universal 201717.0.14 RSU081012017-Apr11 09.29:38 ...uick CalcslDocuments%THE GRAND CARLTON-1446.rup Calo=MJ8 Front Door faces: N Page 1 wrightsoft, Right-JO Worksheet Job: Entire House Date: sy. QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466.6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM 1 Room name BATH BEDROOM 2 2 Egwsed wall 5.0 ft 34.2 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 5 Room dimensions Room area 9.0 x 5.0 ft 45.0 ft' 1.0 x 203.5 ft 203.5 ft' Ty Construction U-value Or HTM Area Load Axes number (BtulVfP-°F (BtuW) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 W < 13A-4ocs.. 0143 in t 4.00 265 40 >, 40 160 - 102: -- 128 128 513 ,. 326 ^-`_4A5-26m �j <'.- - 13A-4= .0770 - 0.143 n�--.. e " 2156 4.00 ;.. 19.31' 2.65 0 0 .� 0' 0 .0.-' 0 0- 0 ``0- 80 'O 56 r:" 0 225 ._ _ ,•0 143 11 f-C �D 1Aclan 11DO 1.270 0.390 a a 3556 10.92 97.29 11.31 0 0 0 0 0 0 0 0 24 0 2 0 848 0 2082 0 W-':13AU4acs-. W Y-C ,. - 13A4=s 0143 0.143 .. se.--= s 4.00: 4.00 255'.. Z55 ..0 0 -0 0 - 0- 0 0-. 0 .•'34. 32 .;34,' 32 136 128 :."., 86 81 1Aalom 13A4ors.-, 4AS2om =,' 12q-0sw 1270 ,0143 .1270 0770. 0.091 5 w. w w - 3556 400 '. f3556 .2156 2.55 34.77 ' 2.55 ..55.21 -.-19.31 1.28 0 - 0` .0-- 0 0 0 0 •0 o'-. 0 0 0 - 0 0... 0 0 .0' 10 .0 0 0 0: 0` 0 0 0 .0. ,0 A 0 0 , 0 0 o 0 0 '�.o '1.0 0 0 `G P .0 -.. ;16A-30md 0.032 - 0.90 Z32 45 45 40 •: 104 204 204 182 ,- " -.4.72 F 22A-tW 0.989 27.69 0.00 45 5 138 0 204 34 946 0 6 c)AED eocursion -16 435 Envelope loss/gain 339 190 2978 3106 12 a) Iriillretion 87 24 593 162 b) Roomvemilatim 0 0 0 0 13 Memo] gains: Occupants @ 230 0 0 1 230 Appliances/other 01 0 Subtotal (lines 6 to 13) 425 214 3571 3498 Less mdenal load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 0 425 0 0 214 0 0 3571 0 0 3498 15 Duct loads 32%a 49% 135 104 32% 49% 1131 1704 Total morn load Air required (cfm) 560 28 318 14 4702 232 5203 232 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft- 2017-Apr-11 09:29:38 I&A RightSuite® Universal 2017 17.0.14 RSU08101 Page 3 ... ulck Calcs\Documenls\THE GRAND CARLTON-1445.rup Calc=MJB Front Doorfaces: N Wrightsoft• Right-J@ Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE M, FT. PIERCE, FL 34946 Phone: 77236"799 Fax 772-466-6796 Email: 1 Room name LAUNDRY GREATIDNNG wall 6.0 ft 47.0 ft 3 R=ed 9 8.0 ft heat1cool 9.8 ft heat/cool 4 Room dimensions 7.0 x 6.0 ft 1.0 x 526.0 ft 5 Room area 42.0 ft2 526.0 fp Ty C=Uucticn U-'Mue Or HTM Area Load Am (ft2) number (Btuhffti F) (Btul✓ft) or perimeter (ft) (Btuh) or perimeter (ft) -(Buh uh) Heat Cool Gross NIP/S Heat Cool Gross I N/P/S. Heat Cool 6 W '13AAocs 5. '0143 n '4.00 2.55 0 0 -. 0 �•. , 0. 255 217 `-. 869 ^552 4A NrrI" .. :' .O770 n. '.: `21.56 . 19.31 ...� 0 ., . 0 -- 0: •..0 ` 38:, : , 0 " 815 2 .730 134-0ccs 0.143 a 4.00 265 0 0 0 0 0 0 0 0 1Ac1= 1.270 a 35.56 8729 0 0 0 0 0 0 0 0 11 `D 11D0 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 W `5 ::. i13A flocs. -13A4acs- 0.143 sw .4.00 .255- 0 `0. 0. 0 0' ..-0... - .0'-...? '0 W 0.143 s 4.00 255 48 48 192 122 0 - 0 0 0 I--l` 1A-c1= 1270 a 3556 34.77 0 0 0 0 0 0 0 0 f13A-0ccs .0143 w : -. ` 400 255 0 0 0 0 - 206 165 , ' , 661 -420 1Ac1om - 1270 w - •.3556 - 55.21 p':. 0=.0 '0 0: o :. •0 0.770 z w 1 " 21.56 , 19.31 0 ,0 ,. 0 . ." "0'. 0 ' 41 41 ". 880 • 788 P 12C-Osw 0.091 - 255 1.28 56 56 143 72 .' 0 0 0 0 C 16A30nd 0.032 - 0.90 232 42 42, 38 97 -526 526 471 1220 F 2244a 0.989 - 27.69 0.00 42 6 166 0 526 47 1302 0 6 c)AED eloursion -22 668 Envelope loss/gain 539 270 4997 4379 12 a) Infiltration 104 28 997 273 b) Room verdilation 0 0 0 0 13 Internal gales: Occupams @ 230 0 0 2 460 Appllancesrother 0 p Subtotal (tires 6 to 13) 643 298 6994 5112 Less eMmrel Iced 0 0 0 0 Less transfer 0 0 0 0 RedistribWan 0 0 0 0 Subtotal 643 298 5994 5112 114 151 Duct loads 32% 49% 204 145 32% 49% 1899 2490 Total room load trequired 848 443 7892 7602 (cfm) 42 20 3901 338 Calculations approved byACCA to meet all requirements of Manual J 8th Ed - wrightsofC 2017-Apr-11 09:29:38 L`h RigND ht-SulteO Universal 2017 17.0.14 RSU08101 page 4 ...ulck CalcslDoe mentsITHE GRACARLTON-1446.mp Cale = MJS Front Door faces: N wrightsoft, Right-J® Worksheet Job: Entire House BySeC Br: QUICK CALCS, INC. 317 ST. LUCIE-LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS@AOLCOM 1 Room name FOYER - M. BATH 2 F�edwall 7.0 ft 8.0.ft 3 Reom height 8.0 ft heallceol 8.0 ft. - heWcod 4 Room dimensions 1.0 x 50.0. ft 7.0 x 8.0 ft 5 Roornarea 50.0 ft2 56.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load —number (BtuhrftUF). (BtulVft2) a perimeter (ft) (Btuh) or perimeter (ft)-- (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cod 6 . 13A-0acs. 0143 n . 400 255 8 "'. 8 32 `. - 20 0 0 - 0' _: 0 ,. <0. �4A5-2oln, ^ :" "0.770 _ n, . "`-2156 - _19.31 _ 0 �; 0 - - ' 0 i- .0 0 , is . 0. - _ 0 'e p LN IaN4 s - 0.143 a 4.00 255 48 - .: 27 108 69 0 0 0 -0 1Aoian 1.270 a 35.56 97.29 0 0 0 0 0 0 0 0 11 I)----GD 11DO 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 W, 13N4ocs ...; =0.143'se" :4.00."^255 s. .:0; i0'-'.-. ,0 �,. .0'_= '0 'b`.r,. 0_ ",:0 y/ I--G 13A4ocs 0.143 s 400 2.55 0 0 0 0 64 57 228 145 1A-clom 1.z7a ,i:m s 3s.56 3a.T7 0 0 0 0 7 7 247 241 '13A-0acs t w ';'400 255 0 .: 0 0 -.0 0 0. 0 0 ' '1Ae1am .: z7a w -35.58 ,6521 0':., 0 W. 0 -o'.. 0 0 %0 - ;4A5-tarn r" . -0770 . w -' '1156 . 1$3f 0 =` 0 -0 - +0 A �' 0- �.. P 12C-0sw 0.091 - 255.- 1.28 72 72 183 92 1) 0 0 0 Envelope loss/gain 7921 496 1 1 747 478 12 a) Infiltration 121 33 138 38 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Applianceslother 0 0 Subtotal (lines 6 to 13) 913 529 885 516 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 913 529 - 885 15 Duct loads 32% 49% 289 258 32% 49% 280 Total room load 1202 787 1166 d251 Air required (cfm) 59 35 58 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - wr79htsoTt- - 2017-Apr-1109:29:38 RIAND Ufte@CAR Universal 2D1.wip Calc 4 RSU0810 Page 5 ...uick Cabs\Dacurtrems\Tffr GRAND CARLTON-1448.rup CaIc=MJB From Door faces: N Duct S stem Summa Job: wrightsoft° y � Date: Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN, FT. PIERCE, FL 34946 Phone: 77246"799 Fax 772-466-6796 Email OUICKCALCS@AOL.COM For: THE GRAND CARLTON WYNNE DEVELOPMENT, FT. PIERCE, FL Extemal_static pressure Pressure tosses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating . 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250. in H2O 0.285 in/100ft 1160 cfm 176 Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.285 iN1D0ft 1160 cfm' Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Dtam (In) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 560 28 14 0.364 4.0 OxO VIFx 22.4 115.0 st1 BEDROOM 2 h 4702 232 232 0.360- 7.0 Ox0 VIFx 23.9 115.0 st1 BEDROOM -A h 3327 164 163 0.300 6.0 OxO VIFx 31.8 135.0 st2 BEDROOM-B h 3327 164 163 0.285 6.0 Ox0 VIFx 40.6 135.0 st2 FOYER h 1202 59 35 0.505 4.0 OxO VIFx 4.0 95.0 - GREATlDINING h 3946 195 169 0.300 7.0 OxO VIFx 31.8 135.0 st2 GREAT/DINING-A h 3946 195 169 0.300 7.0 OxO .VIFx 31.8 135.0 st2 KITCHEN c 3437 21 153 0.379 6.0 Ox0 VIFx 17.0 115.0 st1 LAUNDRY h 846 42 20 0.361 4.0 OxO VIFx 23.3 115.0 st1 M. BATI+A h 768 58 34 0 0 OxO VIFx 0 0 WIC c 174 3 8 0.309 4.0 Ox0 VIFx 27.0 135.0 st2 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (In) (In) Material Trunk st2 Peak AVF 721 . 672 0.285 918 12.0 0 x 0 VinlFlx st1 st1 Peak AVF 1043 1091 0.285 1020 14.0 0 x 0 VinlFlx c FJ�'� wri htsoft` 2017-Apr-1109:29:38 At, '.f 9 RightSufte® UnWma1201717.0.14 RSU08101 Page 1 ...uick CalcslDocuments\THE GRAND CARLTON4446.mp Cale =MJ8 Front Door faces: N Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) StudtJoist Opening (in) Duct Mad Trunk rb1 Ox0 1160 1160 0 0 0 0 Ox 0 VIFx c wri htSofC 2017-Apr-1109.29.38 dC�- 9 Right-S.ke® Universal 2017 l7.0.14 RSU08101 Page 2 ...ulck Calcs\Documents\THE GRAND CARLTON-1446.mp Cale =MJ8 -Front Door faces: N