Loading...
HomeMy WebLinkAboutCERTIFICATION - DESIGN LOAD COMPLIANCEPlanning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) AG2-Fj/� Certification for Design Load Complia ce i� SCIANNE® Project Name: I t'\k- lI-1Y0V-U I my Project Address: :3LJ20 I C'liryl%Q. GT St. Lucie County Permit #: Occupancy Type: Li e Construction Type: INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. ' Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida 2017 Building Code Fifth Edition with 20 NSA Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open 3. Risk Category: _I X II _111 _ IV Exposure Category: _B X C _D 4. Design Wind Velocity 160 mph. X ASD _LRFD End Zone Width: 6 ft 5. Mean Roof Height ft Roof Pitch: 6 :12 Parapet: NSA ft 6. Components & Cladding Design Pressures Used: (PSF, based on losgft @ 15'MRH, clearly label on all plan openings): Zone1:+2o.0,-31.e Zone2: +20.0,-55.3 Zone3: +20'e'-81'7 Zone 4: +34.7,-37.6 Zone s:+34.7,-4e.5 Garage: +29.9,-32.7 7. Design Loads: Floor: 100 PSF Roof/Dead: 12 PSF Roof/Live: 30 Balcony: NIA PSF Dock: NSA PSF Deck: NSA PSF Stairs: NSA PSF Fence: NSA PSF Railings: NSA PSF 8. Were Shear Walls Considered For Structure? _Yes x Not Applicable Explain Why Not: Aspect Ratio < 4:1 9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that, structural elements depicted on these plans provide adequate resistance to the design forcessp , ied: Donald J. Nuelle 62046 ie Date, a Seal Print Name Nuelle Engineering Cert # & Co. Cert Auth. 11634 SW Rowena Street, Port St. Lucie, FL 34987 Company Name & Address Revised