HomeMy WebLinkAboutSOIL NUCLEAR GAUGESoil Nuclear Gauge
Client:
Project: �q Q cDZ7
Gfi�
Report Date: 8/1212019
GHO Homes Corporation
15-0338.00
.{.�
'FRNPT��P
Test Method: ASTM D 6938
590 NW Mercantile Place
SCANNED
Meadowood Golf & Country Club
Part St. Lucie
Port St. Lucie, FL 34986
Fort Pierce, Florida
FBPE CA # 4930
BY
607 NW Commodity Cove
Pod St Lucie, FL 34986
S$. Lucie CouAf
Phone: M-924-3576I Far: 772-924-3580
Test Results
Test#
Retest
Of
Test
Date
ProctorlD
Method
Soil
Classification
Optimum
Moisture
N
Maximum
Dry Density
p
In Place
Moisture
%
In Place
Dry Density
(pcf)
Probe
Depth
(in)
Percent
Compaction
Min/Max
Comp.
%
Remark
124
8/9/19
P-3
N/A
11.2
113.3
11.0
108.3
12
96
95 / 105
Pass
125
8/9119
P-3
N/A
11.2
113.3
11.5
108.9
12
96
95 / 105
Pass
126
8/9/19
P-3
N/A
11.2
113.3
10.9
109.4
12
97
95 / 105
Pass
+-
Test Information
Test #
Test Location
Elevation
Reference
Gauge
Make / Model / SN / Calibrated
Field Technician
124
Below Slab Grade: 3604 Grove Court, Lot 13,North Corner
0-1
Troxler / 3430 124566 /
Hayes, Sean
125
Below Slab Grade: 3604 Grove Court, Lot 13, South Comer
0-1
Troxler / 3430 / 24566 /
Hayes, Sean
126
Below Slab Grade: 3604 Grove Court, Lot 13, Center
0-1
Troxler / 3430 / 24566 /
Hayes, Sean
Remarks!
Comments
Pass: Tests results comply with specifications
Tests are "Direct Transmission" (Method A) unless probe depth is noted as
"Backscatter". Gauge calibration data on file with the testing agency.
RECEIVED
AUG 1 3 2019
ST. LUCle County, Permitting
Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc.
.• �1GENSF''•
No 6,il
ixent, P � ' X_
�ssionngpleer t$
Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
Page 1 of 1