Loading...
HomeMy WebLinkAboutCERTIFICATION - DESIGN LOAD COMPLIANCE7!i U► TY L O R I D A Planning& Development Services Department RECEIVED Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982— (772) 46P-1553 Certification for Design Load Compliance Project Name: Custom Residence JUN 18 2019 Permitting Department St. Lucie County, FL Project Address: Lot 6 Avalon Beach P.U.D, Ocean Estates Drive, North Hutchinson Island, FL Permit #: Occupancy Type: R-3 Construction Type: V"B AI.aP Nt4ED INSTRUCTIONS FOR USE: . ��� Cr+oU BY • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Building Code Sixth Edition with 2017 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open 3. .Risk Category:I X II _lll_IV Exposure Category: BC X D 4. Design Wind Velocity 170 mph ASD X LRFD End Zone Width:4.32 ft S. Mean Roof Height 28.10 ft Roof Pitch: 7 :12 Parapet: ft 6. Components & Cladding Design Pressures Used: (PSF, based on 30sgft @ 15'MRH, clearly label on all plan openings): Zone 1: -45,90 Zone 2: -76.89 Zone 3: -114.99 Zone 4: -50.28 Zone 5: -58.07 Garage: -53.82 7. Design Loads: Floor: 138 PSF Roof/Dead:35 PSF Roof/Live:20 Balcony: 125 PSF Dock: N/A PSF Deck: N/A PSF Stairs:40 PSF Fence: PSF Railings: PSF 8. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not: 9. Is A Continu us Load Path Provided? X Yes NotApplicable Explain Why Not: M�EVMEWED FOR IIII U r/// :2500 PSF Soil Test Reports Submitted? YCODE COMPLIANCE GENS .TT9�i�i CATION STATEMENT: ST. LUCIE COUNTY * : wledge and belief, the attached plans & specifications have been oe ° 7=_Ictural portions of the building codes currently adopted and enforced by St. Lucie -tural elements depicted on these plans provide adequate resistance to the design �0 .••. STAT : •\��� Farid Abugattas PE 72471 �C�s•••'PGORIDP.•' Print Name Cert # & Co. Cert Auth. 11111�I ``�\ 06/14/2019 Project Classic LLC Signature, Date, and Seal 7318 Texas Trail, Boca Raton, FL. 33487 Company Name & Address Revised 12/07/2018 PILE