HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Gentile Corp - Moore - Jones Residence
Street: 2604 Sterling Corurt
Builder Name: \^
Permit Office: St. Lucie County
City, State, Lip: Fort Pierce, FL, 34946
- -Owner- Gentile Corp. - Moore - Jones Residence
Permit Number:
Jurisdiction: St. Lucie County
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climat
ns y
1. New construction or existing New (From Plans)
9. Wall Types (1232.0 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block- Ext Insul, Exterior
R=4.1 1232.00 112
�1
b. WA
R= ft2
3. Number of units, if multiple family 1 IRI
c. N/A
R= ft2
4. Number of Bedrooms 4 BY
d. N/A
R= ft2
5. Is thisaworst case? No,�
10. Ceiling Types (1354.0 sqft.)
Insulation Area
u Under Attic (Vented)
R=30.0 1354.00 ft2
6. Conditioned floor area above grade (ft2) 1354
. WA
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R 112
7. Windows(90.0 sgft.) Description Area
a. Sup: Attic, Ret: Hall, AH: Laundry
6 115
a. U-Factor: Dbl, U=0.65 90.00 ft2
SHGC: SHGC=0.25
b. U-Factor: N/A ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
29.0 SEER:16.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Strip Heat
27.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 1.000 ft.
Area Weighted Average SHGC: 0.250
14. Hot water systems
a. Electric
Cap: 50 gallons
8. Floor Types (1354.0 sqft.) Insulation Area
EF: 0.950
a. Slab -On -Grade Edge Insulation R=0.0 1354.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
CF, Pstat
Glass/Floor Area: 0.066 Total Proposed Modified Loads: 45.23
PASS
SS
Total Baseline
Loads: 48.98
rd��7
1 hereby certify that the plans and specifications covered by
Review of the plans and
this calculation are in compliance with the Florida Energy
specifications covered by this,
OFTHfi'Sr97F
_, pA
Code.
calculation indicates compliance
y rip "' _ ,�;." 10
`.'•3,° l0
with the Florida Energy Code.
F rrur. '. =S` o
PREPARED Y:
Before construction is completed
r C
DATE:
this building will be inspected for
compliance with Section 553.908
a
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energ7/ppde.-n
_COD;yfi'T¢�
OWNER/AGENT. V/�NU/Qt" �'
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
5/16/2019 9.32 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: Gentile Corp -Moore -Jones Bedrooms: 4
Address Type:
StreetAddress
Building Type: User
Conditioned Area: 1354
Lot#
Owner Name: Gentile Corp. - Moore -
Jones Total Stories: 1
Block/Subdivision:
#of Units: 1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street:
2604 Sterling Corurt
Permit Office: St. Lucie County
CrossVentilation: No
County:
St. Lucie
Jurisdiction: St. Lucie County
Whole House Fan: No
City, State, Zip:
Fort Pierce,
Family —Type, Single-family
FL, 34946
New/Existing: New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp Heating
Design Daily Temp
V Design Location
TMY Site 97.5%
2.5%
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39
90
70
75 299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1354 10832
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
InfillD Finished Cooled
Heated
1 Bedroom 4
154 1232 No
2
1
1 Yes
Yes
Yes
2 Bath
66 528 No
0
1 Yes
Yes
Yes
3 Bedroom 3
143 1144 No
2
1
1 Yes
Yes
Yes
4 Bedroom 2
154 1232 No
2
1
1 Yes
Yes
Yes
5 Hall
100 800 No
0
1 Yes
Yes
Yes
6 Master Bedroom
182 1456 No
2
1
1 Yes
Yes
Yes
7 Master Bath
84 672 No
0
1 Yes
Yes
Yes
8 Laundry
84 672 No
1
1 Yes
Yes
Yes
9 Kitchen
153 1224 Yes
2
1 Yes
Yes
Yes
10 Living Room
234 1872 No
2
1 Yes
Yes
Yes
FLOORS
# FloorType
Space Perimeter PerimeterR-Value
Area
JoistR-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge lnsulatio
Bedroom 25ft
154 ft'
1 0
0
2 Slab -On -Grade Edge lnsulatio
Bath Eft
66 ft'
____
1 0
0
3 Slab -On -Grade Edge lnsulatio
Bedroom 1311
143 ft'
____
1 0
0
4 Slab -On -Grade Edge lnsulatio
Bedroom 25ft
154 ft'
1 0
0
S Slab -On -Grade Edgelnsulatio
Hall 4ft
100 ft'
___
1 0
0
6 Slab -On -Grade Edgelnsulatio
Master Bedroom 27ft
182 ft'
___
1 0
0
7 Slab -On -Grade Edge lnsulatio
Master Bath Eft
84 ft'
___
1 0
0
5/16/2019 9:32 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
#
Floor Type Space Perimeter Perimeter R-Value
Area
JoistR-Value
Tile
Wood Carpet
8 Slab -On -Grade Edge lnsulatio Laundry 7ft
84 ft2
-__
1
0
0
9 Slab -On -Grade Edge lnsulatio Kitchen 9ft
153 ft2
1
0
0
10SIab-On-Grade Edge lnsulatio Living Room 32ft
234 ft2
_-__
1
0
0
ROOF
/
Roof
Gable
Roof
Red
Solar
SA Emitt
Emitt Deck
Pilch
V
#
Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
Hip Compositionshingles 1427 ft2
0 ft2
Medium
N
0.6
No 0.9
No 0
18.4
ATTIC
/
V
#
Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Fullattic Vented
150
1354
ft'
N
N
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
UnderAttic(Vented) Bedroom
30
Batt
154 ft2
0.1
Wood
2
UnderAttic(Vented) Bath
30
Batt
66 ft2
0.1
Wood
3
UnderAttic(Vented) Bedroom
30
Batt
143 ft2
0.1
Wood
4
Under Attic (Vented) Bedroom 2
30
Batt
154 ft2
0.1
Wood
5
UnderAttic(Vented) Hall
30
Batt
100 ft2
0.1
Wood
6
UnderAttic(Vented) Master Bedroom
30
Batt
182 ft'
0.1
Wood
7
Under Attic (Vented) Master Bath
30
Batt
84 ft'
0.1
Wood
8
Under Attic (Vented) Laundry
30
Batt
84 ft2
0.1
Wood
9
Under Attic (Vented) Kitchen
30
Batt
153 ft2
0.1
Wood
10
UnderAttic(Vented) Living Room
30
Batt
234 ft2
0.1
Wood
WALLS
Adjacent Space Cavity Width
Height
Sheathing Framing Solar
Below
_ 1
N
Exterior Concrete Block- Ext lnsuBedroom 4
4.1 14
0 8
0
112.Oft2
0
0
0.6
0
_2
E
Exterior Concrete Block- Ext lnsuBedroom 4
4.1 11
0 8
0
88.0 ft2
0
0
0.6
0
3
N
Exterior Concrete Block -Ext lnsul Bath
4.1 6
0 8
0
48.0 ft2
0
0
0.6
0
4
N
Exterior Concrete Block- Ext lnsuBedroom 3
4.1 13
0 8
0
104.0 ft'
0
0
0.6
0
5
N
Exterior Concrete Block- Ext lnsuBedroom 2
4.1 14
0 8
0
112.Oft2
0
0
0.6
0
6
W
Exterior Concrete Block- Ext lnsuBedroom 2
4.1 11
0 8
0
88.0 ft2
0
0
0.6
0
7
E
Exterior Concrete Block -Ext lnsul Hall
4.1 4
0 8
0
32.0 ft'
0
0
0.6
0
_ 8
E
Exterior Concrete Block- Ext InsUaster Bedro
4.1 14
0 8
0
112.O ft2
0
0
0.6
0
_ 9
S
Exterior Concrete Block- Ext lns1laster Bedro
4.1 13
0 8
0
104,O ft2
0
0
0.6
0
10
S
Exterior Concrete Block- Ext lnsWlaster Bath
4.1 6
0 8
0
48.0 ft'
0
0
0.6
0
_ 11
S
Exterior Concrete Block-Ext Insul Laundry
4.1 6
0 8
0
48.0 ft2
0
0
0.6
0
_12
W
Exterior Concrete Block -Ext lnsul Laundry
4.1 1
0 8
0
8.0 ft'
0
0
0.6
0
5/16/2019 9:32 AM EnergyGaugeO USA 6.0.02 (Rev. 1)-FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent Space Cavity Width
Height
Sheathing Framing Solar Below
_ 13 S
_ 14 E
_ 15 S
16 W
Exterior Concrete Block- Ext Insul Kitchen 4.1 9 0 8
Exterior Concrete Block- Ext InsLffl ing Room 4.1 1 0 8
Exterior Concrete Block- Ext Insdliving Room 4.1 13 0 8
Exterior Concrete Block- Ext lnsdliving Room 4.1 18 0 8
0
0
0
0
72.0 ft' 0
8.0 ft2 0
104.0 ft2 0
144.0 ft2 0
0 0.6
0 0.6
0 0.6
0 0.6
0
0
0
0
DOORS
#
Ornt Door Type Space Storms
U-Value Width
Ft In
Height
Ft In
Area
1
2
E Wood Hall None
W Wood Living Room None
.39
.39
3
3
6 10
6 10
20.5 ft'
20.5 ft2
WINDOWS
Orientation shown is the entered, Pro osed orientation.
V #
Wall
Ornl ID Frame Panes NFRC U-Factor SHGC Imp
Area
Overhang
Depth Separation
Int Shade
Screening
1
2
3
_ 4
5
E 2 Metal Low-E Double Yes 0.65 0.25 N
N 4 Metal Low-E Double Yes 0.65 0.25 N
W 6 Metal Low-E Double Yes 0.65 0.25 N
E 8 Metal Low-E Double Yes 0.65 0.25 N
W 16 Metal Low-E Double Yes 0.65 0.25 N
15.0 ft2
15.0 ft2
15.0 ft'
15.0 ft2
30.0 ft2
1 It 0 in 1 ft 4 in
1 It 0 in 1 R 4 in
1ft0in 1ft4 in
1 It 0 in 1 It 4 in
1ft0in 1ft4 in
None
None
None
None
None
None
None
None
None
None
INFILTRATION
# Scope
Method SLA CFM 50 ELA EgLA
ACH ACH 50
1 Wholehouse Proposed ACH(50) .000356 1263.7 69.38 130.47
.1233
7
HEATING SYSTEM
#
System Type Subtype Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat/ None COP:1
27kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type Subtype Efficiency
Capacity Air Flow SHR Block
Ducts
1
Central Unit/ Split SEER: 16
29 kBtulhr cfm
0.7 1
sys#1
HOT WATER SYSTEM
#
System Type SubType Location EF Cap
Use
SetPnt
Conservation
1
Electric None Laundry 0.95 50 gal 60.9 gal
120 deg
None
5/16/2019 9:32 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
Woff YoTqtTjffWEN I0•I01III&IIIIlt4h4/_lX1993.Ixd:A1-11111Aael-. ➢
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # Company Name
System
Model# Collector Model#
Area Volume
FEF
None None
ft2
DUCTS
Supply—
—Return—
Air
CFM 25
OFM25
HVAC#
V # Location R-Value
Area
Location
Area
Leakage Type
Handler
TOT
OUT ON RLF
Heat Cool
1 Attic
6 115 ft2
Hall
20 ft2
Default Leakage
Laundry
(Default)
(Default)
1 1
TEMPERATURES
Programabl(eT��hermostatt[:,Y
Crfeiling Fans:
Heat ng IX] Jan Feb
rX],�
Mar
DC
Jun [ i Jul
j j
Aug
�X
[ i Sep
(r)(')
Nov
Dec
Venting [[ 11 Jan I
l J
1 Feb
IXl Mar
lxl
Apr
[
May
lXl Jun I Jul
Ex)
1 Aug
I Sep
Oct [X]
Nov
Dec
ThermostatSchedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5 6
7
8
9 10
11
12
Cooling (WD)
AM
78
78
78
78
78 78
78
78
80 80
80
80
PM
80
80
78
78
78 78
78
78
78 78
78
78
Cooling (WEH)
AM
78
78
78
78
78 78
78
78
78 78
78
78
PM
78
78
78
78
78 78
78
78
78 78
78
78
Heating (WD)
AM
66
66
66
66
66 68
68
68
68 68
68
68
PM
68
68
68
68
68 68
68
68
68 68
66
66
Heating(WEH)
AM
66
66
66
66
fib 68
68
68
68 68
68
68
PM
68
68
68
68
68 68
68
68
68 68
66
66
MASS
Mass Type
Area
Thickness
FurnitureFraclion
Space
Default(8lbs/sq.ft.
0 ft2
0 ft
0.3
Bedroom 4
Default(81bs/sqft
ft2
ft
0.3
Bath
Default(81bs/sq.ft.
ft2
ft
0.3
Bedroom 3
Default(81bs/sq.ft.
ft2
It
0.3
Bedroom 2
Default(8lbs/sq.ft.
ft2
It
0.3
Hall
Default(8lbs/sq.ft.
ft2
It
0.3
Master Bedroom
Default(81bs/sq.ft.
ft2
It
0.3
Master Bath
Default(8lbs/sq.ft.
ft2
It
0.3
Laundry
Default(8lbs/sq.ft.
ft2
ft
0.3
Kitchen
Default(81bs/s .ft.
ft'
ft
0.3
Living Room
5/16/2019 9:32 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Gentile Corp - Moore - Jones Residence Builder Name:
Street: 2604 Sterling Corurt Permit Office: St. Lucie County
City, State, Zip: Fort Pierce , FL, 34946 Permit Number:
Y
U
Owner: Gentile Corp. -Moore -Jones Residence Jurisdiction: St. Lucie County
w
_ Design Location: FL, Fort Pierce
0
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in an dro ed ceilin /soffit
Y dropped 9
the insulation and any gaps in the air bander shall be sealed.
shall be aligned with the air border.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the lop side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire solinkler cover plates and walls or cemlinag
a. In aaonion, inspection or log walls shall be in accordance with the provisions of ICC-400.
6/16/2019 9:34 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 92
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply duds R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location Laundry
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
4
13. Cooling system: Capacity
29.0
a) Split system SEER
16.0
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/Water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1354
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.650
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.250
14. Heating system: Capacity
27.0
c) Area
7c.
90.0
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
1.0
a) U-fador.(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.95
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF_
2. Masonry (Insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10B1.
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans Yes
a) Under attic 11a. 30.0
b) Cross ventilation No
b) Single assembly 11b.
c) Whole house fan No
c) Knee walls/skylight walls 11c.
d) Multizone cooling credit
d) Radiant barrier installed 11d. No
e) Multizone heating credit
f) Programmable thermostat Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature:
Wan
�
("
Date: 0(0'03- 1
1
Address of New Home:
2604 Sterling
orurt
City/FL Zip: Fort Pierce, FL 34946
5/16/2019 9:34:01 AM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
- wrightsoftProject Summary Date:
Entire House By:
Quick Callas, Inc.
317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 7724666799 Email: quickWIl @aol.com
Project• •
For: Gentile Corp. - Moore - Jones Residence
_ 2604 Sterling Corurt, Fort Pierce, FL 34946
Notes:
Design
Information
Weather:
Fort Pierce, FL, US
Winter Design Conditions
Summer Design Conditions
Outside db 42 OF
Outside
db
90
OF
Inside db 70 OF
Inside
db
75
OF
Design TD 28 OF
Design TO
15
OF
Daily range
M
Relative humidity
50
%
Moisture difference
61
gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure
14773
Btuh
Structure
16079
Btuh
Duds
4051
Btuh
Duds
4945
Btuh
Central vent (0 cfm)
0
Btuh
Central vent (0 dm)
0
Btuh
e)
Humnone
idification
0
Btuh
Blower
0
Btuh
Piping
0
Btuh
Equipment load
18824
Btuh
Use manufacturer's data
n
Rate/swingg multipplier
Equipment load
0.95
19973
Btuh
Infiltration
sensible
Method
Simplified
Latent Cooling Equipment Load Sizing
Construction quality
Average
Fireplaces
0
Structure
4335
Btuh
Ducts
1538
Btuh
Central vent (0 dm)
0
Btuh
Heating
Cooling
(none)
Area (ft2)
1354
1354
Equipment latent load
5873
Btuh
Volume (ft)
10832
10832
Air changes/hour
0.45
0.23
Equipment Total Load (Sen+Lat)
25846
Btuh
Equiv. AVF (dim)
81
42
Req. total capacity at 0.70 SHR
2.4
ton
Heating Equipment Summary
Cooling Equipment Summary
Make
Make Rheem
Trade
Trade RHEEM
Model
Cord RA1630AJlNB
AHRI ref
Coil RH1T3617STANAA
AHRI ref 7941343
Efficiency
100 EFF
Efficiency 13.0 EER,
16 SEER
Heating input
5.4
kW
Sensible cooling
20300
Btuh
Heating output
18446
Btuh
Latent cooling
8700
Btuh
Temperature rise
17
OF
Total cooling
29000
Btuh
Actual air flow
967
dm
Actual air flow
967
dm
Air flow factor
0.051
dm/Btuh
Air flow factor
0.046
dm/Btuh
Static pressure
0.50
in H2O
Static pressure
0.50
in H2O
Space thermostat
Load sensible heat ratio
0.78
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
-i�i- wHahtmo}f- 2016May-16 09:53:42
.-.�--��.-. Right -Suite® Universal 201919.0.01 RSU08101 Page 1
...HVAC\Genble Corp - Moore - Janes Residence.rup Calc=MJB Front Door faces: W
wrightsoft' Right-M Worksheet Job:
Entire House Date:
By:
Quick Calcs, Inc.
317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466.6799 Email: quickcalcs@aol.com
1
2
3
4
5
Room name
Exposed wall
Room height
Room dimensions
Room area
Entire House
154.0 It
8.0 it
1354.0 ft'
Bedroom 4
25.0 it
8.0 it heat/cool
11.0 x 14.0 it
154.0 ft.
__
Ty
Construction
number
U-value
(Btuh/ft"F.
I or
14TM
I (8luh/ft`
Area (ft')
I or perimeter (ft) I
Load
(Btuh) I
Area (ft')
or perimeter (ft) I
Load
(Btuh)
Heal
Coal
Gross
WP/S
Heat
Gross
N/P/S
Heat
Cool
6
17
Yt/
L1'
13A-4ocs
4A5-2om, __ __. _
73A-4ocs
4A5-2om
11DD
_. _ _ _
73A-flocs_ ._-.__-._ _
13A4oes
4A5-2om
11DQ._ -
16B-30ad ,. _- __.__
22A-tot _�-
-_.__
0.143
- _0.770
0.143
0.770
0.390
_ __ _
.__ _0.143
0.143
0.770
_ .0.390
_0.032
- _ 0.989
_
n
_ n
a
a
a
._ s_
w
w
w.
_ _
_ ,-
..._-_-..._..
4.0g
21.56
4.00
21.56
10.92
._
4.00
4.00
21Sfi
�10.92
--_. 0.90
27.69
2.14
__19.31
2.19
47.10
10.34
--2.19
2.19
47.10
__10.34
_„._ 1.60
„-_,-0.00
_._.-_.
378
_ ..- 15
240
30
_ _ _ 20
._- _ _- 376
240
45
_.20
_�._1354
-_-,_1354
..-
361
.__ 's0.
190
0
20
�._
_-...378
175
0
20
_-'_. 1354
154
-
1445
_. __323
759
647
2.23
. _ _.
_._ _.1508
699
970
---- 223-_--_211
_.. -_1213
-_4265
_Cool-
� 790
_____290
415
1413
_ 211
_- _.823
382
2120
_._:2166
--�_ _0
-_.__-___-._..Y-._.
112
-.-__0
88
15
0
.. __. _-..10
0
0
__ 0_
^_.-154
154
112
---,._0
73
0
0
, 448
- --- , 0
292
323
0
-- __0
0
0
0
_,____138
_ 692
_.__.-..
245
,__,__ 0
160
707
0
. __._0
0
0
__,-_0
'.__ 246
0
_
w
i11
. _.._-„0
0
0
,0___
_ -154
25
L�_pG
-
C.
F
61
c)AED excursion
185
-43
Envelope loss/gain
1 12273
9005
1894
1314
12
a) Infiltration
b) Room ventilation
2500
1 0
685
0
406
0
111
0
13
Internal gains: occupants@ 230
Appliancesremer
13
2990
3400
2
460
0
Subtotal (lines 6 to 13)
14773
16079
i
2300
1885
14
15
Less external load
Less transfer
Redistribution
Subtotal
Duct loads
27%
31%
0
0
0
14773
4051
0
0
0
16079
4945
27%
31%
0
0
139
2439
669
0
0
102
1987
611
Avhireeaquued'(cfm)
I
I 18967I 824
27967I
I
I 3160I
25981
719
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
- l��9lxlao�ft-' 2019-May-1609:53:42
Right -Suite® Universal 201919.0.01 RSU08101 Page 1
...HVMGentile Corp - Moore - Jones Residence.mp Colo -MJ8 Front Door faces: W
wrightsoft° Right-3® Worksheet Job:
Entire House Date:
ay:
Quick Calcs, Inc.
317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quicacalw@aol.com
1
2
3
4
5
Room name
Exposed wall
Room height
Room dimensions
Room area
Bath
6.0 ft
8.0 ft heat/cool
11.0 x 6.0 ft
66.0 ft.
Bedroom 3
13.0 ft
8.0 ft heal/cool
11.0 x 13.0 ft
143.0 fl'
_
Ty
Construction
number
U-value
(Btuh/ft'-°F
Or
HTM
I (Btuh/M
Area (fP)
I or perimeter (0)
Load
I. (Btuh) I
Area (ft-)
or perimeter (ft)
Load
I (Bhm)
Heat
Cool
Gross
WP/S
Heat
Cool
Gross
WP/S
Heat I
Cool
1
6
11
Vtl
13A-flocs ---- �
4A5-2om __ __-_.__
13A-4ocs
4A5-tom
1.100
..
13A-4acs _.._ . _. __
73A-4ans
4A5-tom
11DO .. _ _
16B30ad
22A-tol-___ - _-.
0.143
._0.770.
0.143
0.770
0.390
__ _
_, _ 0.143
0.7
0.770 70
.__ 0.390.
-._.0.032
-_- .0.989
n
n_
a
a
a
__ ..
_ s
w
w
w_
-.-_
_
4.00
- 21.58
4.00
21.56
W0 92
.._.
-_ 4.00
4.
27.56 58
_10.92
__ .0.90
27.69
_ � 2.19
'_.19.37.
2.19
47.10
10.34
_.._
_ _, 2.19
2.1
47.10
-_10.34
. _-_1'.60
-. 0.00
' - 48
_ _ _0
0
0
0
__
-. _.__ D
0
0
,_0
_._ 66
66
-48
_'_____0
0
0
_.__.. 0
_...._._-0
0
0
-0
____66
.--_ _ 6
�-�192-705-
__ _.0^._.-0___.,_.15
0
0
0
__. ___..__.
J__.. _0
0
0
_..0
._ _..- 59
_ 166
0
0
0
,._.
_�..�0
0
0
0____
____106.__;743
_ -_-___ 0
04 �1
0
0
.0
._ ..__.0
0
0
0__.TP..._�.
143
'--- 89
_.___0
0
0
0
s_.__0
0
0
Y..__143
_73
-, 358
__.__.323
0
0
0
_. _.�.,_.__.
_�_ _.0
0
0
0
___128
_ _360
195
290
0
0
0
0
0
0
: a_ 229
_.___0
_
W. _
-
C
F
6
c)AED excursion
-65
Envelope loss/gain
417
112
98
1788
849
12
a) Infiltration
b) Room ventilation
1
97
0
27
0
211
0
58
0
13
Internal gains: Occupants @ 230
Applianceslother
0
0
0
2
460
0
Subtotal (lines 6 to 13)
515
2.25
1379
1766
14
15
Less external load
Less transfer
Redi5a button
Subtotal
Duct loads
27%
31%
0
0
59
574
157
0
0
44
268
83
27%
31%
0
0
49
1428
392
0
0
36
1203
370
Airlequired (dm)
I
I 738
3b8I
I 1893I
1572
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed
-r w 2019-May-16 09:53:42
Right -Suite® Universal 201919.0.01 RSU08101 Paget
...HVAC1Gen61e Corp - Moore - Jones Residencenup Cale =MJB Front Door faces: W
wrightsoft• Right-J® Worksheet Job:
Entire House Date:
By:
Quick Calcs, Inc.
317 St. Lurie Lane, Fort Pierre, FL 34946 Phone: 772466-6799 Emal: quicktalcs@aoLcom
1
Room name
Bedroom 2
Hall
2
Exposed wall
25.0 ft
4.0 ft
3
Room height
8.0 ft heat/cool
8.0 it heat/cool
4
5
Room dimensions
Room area
11.0 x 14.0 It
154.0 IP
4.0 x 25.0 It
100.0 fP
Ty
Construction
U-value
I Or
HTM
I
Area (fP)
I
Load
I
Area (W)
I
Load
I
number
(Btuh/ftk Fy
(Btuh/ft0
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Coal
Gross
WP/S
Heal
Cool
6
y/
13A-4ocs
---0.7
n
4.
2.
712
_._
112
44
245
0
0
0
0
L—G
4A5c2om _ _. _
0.77700
n.
. 21.56
_, 19.31
.� _ 0
., _. 0----,
0 0
_0
------0
_ _ —0
_-.0
__ __ 0
13A-4ocs
0.143
a
4.00
2.19
0
0
0
0
32
12
46
25
4A5-2om
0.770
a
21.56
47.10
0
0
0
0
0
0
0
0
71
11DO
13A-flocs._. _ .._
0.390
- _0.143,
a
s_
10.92
._ 4.00
10.34
_._2.19
0
,.._._ .0-.
0
_ v0
0
0
0
_-,-0
20
__-.-._O
20
i_.__._0.
223
__,__0
271
,.,—.._0
.W.
y/
13A-4ocs
0.143
w
4,00
2.19
88
73
292
160
0
0
0
0
4AS-20M
0.770
w
21.56
47.10
15
0
323
707
0
0
0
0
_
C
11D0--___ _.
16B-30atl _ _. ._._..
-_ _0,390
_ 0.032
_w_
_ -_
10.92
_ 0.90
-_10.34
.:7.80
0_
__.541
_0
-__-754
_._0_
_.. -.. _738
0,-_.
..._._246
__. 0_
_-.-__700
,__ 0
_:500
0
_,._._90
_0
__.160
F
22A-tol
0.989
27.69
0.00
154
25
692
0
100
4
111
0
61
c) AED excursion
200
-22
Envelope loss/gam
I 1894
1558
470
374
12
a) Infiltration
406
111
fi5
18
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
2
460
0
1
1
0
Appliances/other
0
0
Subtotal (lines 6 to 13)
2300
2129
1
1 535
392
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
-535
-392
14
Subtotal
2300
2129
0
0
15
Duct loads
27%
31%
631
655
27%
31%
0
0
Toal
2957I
2728
Airtre9uiretl (1)
I
I OI
O
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
OFF = t=oTTrC- 2019-May-1609:53:42
Right -Suite® Universa1201919.0.01 RSU08101 Page
...HVAMGentile Corp - Moore - Jones Residence.rup Cale =MJ8 Front Doorfaces: W
wrightsoft• Right-J® Worksheet Job:
Entire House Date:
ay:
Quick Calcs, Inc.
317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466,6799 Email: quickcalcs@aol.com
1
Room name
Master Bedroom
Master Bath
2
Exposed wall
27.0 ft
6.0 ft
3
Room height
8.0 ft heat/cool
8.0 ft heat/cool
4
5
Room dimensions
Room area
14.0 x 13.0 ft
182.0 ft2
14.0 x 6.0 ft
84.0 fP
Ty
Construction
U-value
Or
HTM
I
Area (fl2)
I
Load
I
Area (ft.)
I
Loatl
I
number
(Bluh/flI TI
(BtuN(t')
or perimeter (ft)
(BWh)
or perimeter (%)
Eh)
Heat
Caol
Gross
NIP/S
Heat
Cool
Gross
N/P/S
Heal
Cool
fi
Vrl
13A-0acs
- 0.770
n
4.56
2.19
- -- 0
0
0
, 0
0
0
0
- 0
_�('
4AS2om __ _..__.
_ 0.770.
n_
21.58
___19.31
___. _.0
_-__, 0.,___0
,
_-,_.�0__.__.0
�._._0
_
._.._ _0
r 0
ILG13A4ocs
0.143
a
4.00
2.19
112
97
388
212
0
0
0
0
4A5-20m
0.770
a
21.56
47.10
15
0
323
707
0
0
0
0
11
11D0
13A-4acs. .__
0.390
_0.143
a
.a.
10.92
. .4.00
10.34
_ ...2.19
_ 0
_ _ __704
_ 0
_ .__164_._.
0
416
0
__ 226
_ 0
__. _48-.-48
_ 0
_ 0
__ _192
0
____105
W
13A-4ocs
0.143
w
4.00
2.19
0
0
0
0
0
0
0
0
4A5-2om
0.770
w
21.56
47.10
0
0
0
0
0
0
0
0
11DO _
0.390
-vv
10.92
0
0___.
0
C
t8&30atl __..___
__._.0.032
..-__
_ 0.90
__10.34
__. 1.60
_.. _
_. .782
.�. _0
_. __182'_.__
_
_ _
_163
___0
...... 291.__.._._84,_-_,84
_�___0.______0
__ _-.
._..__75
____�0
F
22A-tol
0.989
27.69
0.00
182
27
748
0
84
fi
166
0
61
c)AED excursion
-4
-7q
Envelope loss/eain
i 2039
1389
1
1 434
225
12
a) Infiluetion
438
120
97
27
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants Q 230
2
460
0
0
Appliances/omer
0
0
Subtotal (lines 6 to 13)
2477
1969
531
252
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
129
94
59
44
14
Subtotal
2606
206 4
590
296
15
Duct loads
27%
31%
715
635
27%
31%
162
91
�Nrt
eQ ueC (cftlm)
I
I 3171I
2124I
I
I 739I
3181
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed
-rk- wrsgtiltr� rz- 2019-May-1609:53:42
Right -Suite® Universal 201919.0.01 RSUD8101 page
...HVAC\Gentile Corp - Moore - Jones Residence.rup Cato =MJS Front Door faces: W
wrightsoft• Righttil® Worksheet Job:
Entire House Date:
Quick Calcs, Inc. By,
317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772466-6799 Email: quickcalcs®aol.com
1
Room name
laundry
Kitchen
2
Exposed wall
7.0 It
9.0 ft
3
Room height
8.0 itheatt000l
8.0 ft heat/cool
4
5
Roam dimensions
Room area
14.0 x 6.0 ft
84.0 ft.
17.0 x 9.0 ft
153.0 fl'
_
Ty
Construction
U-value
Or
HTM
Area (ft2)
Load
Area (ft•)
Load
number
(Btuh/ft T
(Btuh/ft'
I or perimeter (ft)
I. (Btuh)
I or perimeter (0)
(Bmh)
He
Cool
Gross
WP/S
Heat
Cool
Gross
NIP/S
Heat
Cool
1
6
try
�f'
13A-4acs
0.143
n
4.00
2.79
T
_0
.,- -'----0
_ _O
--6
---"-0
0
U
-�'-U
4A5-20m _ _-
_ .0.770
-n
- 21.56
19.31
_ 0
- _.- 0
_. .0
M _ 0
_ _-- 0
0
__.__, 0
-- , ,0
_
13A-4ocs
0.143
a
4.00
2.19
0
0
0
0
0
0
0
0
4A5-20m
M.
0.770
a
21.56
47.10
0
0
0
0
0
0
0
0
11
11DO
-
0.390
a
10.92
10.34
0
0
0
0
0
0
0
0
_
W
_
13A-4ocs_ _._
_
0.143
s
4.00
._ _-._....
_2.19.....,_-_48
._
_.__48
_ _
.. ..132__..-118_,_.__._72-.___70
__-_
..
_�.-
._-____..___._
_-__-260
..
YI!
13A-40cs
0.770
w
2.10
8
8
32
18
0
0
0
0
0
4A5-20m
0.770
w
1.56
21.5G
47.10
0
0
0
0
0
0
0
0
L�_.pO
11D0-_ _...
U
0
0
0
0
0
C
16&30atl .
_0.390_w-__10.92
0.032
. -
.. 0.90
_..10.34
_1.60
.._-__0
_ _ 84
_ . _ 84
__ - 75
_
. __. -_134
-�-._
__ .._._0153
,- -.-153
__:_ -.137.
,-.._ 246
F
22A-tol
0.989
27.69
0.00
84
7
194
0
153
9
249
0
6
c)AED excursion
-53
-152
Envelope loss/gain
493
204
675
250
12
a) Infiltration
114
31
146
40
b) Room ventilation
0
0
0
0
73
Internal gains: Occupants@ 230
1
230
2
1
460
Appliancesrother
500
2000
Subtotal (lines 6 to 13)
1 6071
965
1
1 821
2750
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
59
44
40
29
14
Subtotal
666
1008
860
2779
15
Duct loads
27%
31%
183
310
27%
31%
236
855
Totaload
8 9I
136LJ
10568I
388
qu ed (rim)
I
I
I
11
I
I
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed
-'{4- w- 11- M o2019-May-16 09:53A2
Right -Suite® Universal 201919.0.01 RSU08101 Page
...HVAMGenlile Corp - Moore - Jones Residence.rup Cate =MJ8 Front Doorfaces: W
wrightsoft• Right!® Worksheet Job:
Entire House Date:
Quick Calcs, Inc. By:
317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: qulckcalcs®aol.cam
i
2
3
4
5
Room name
Exposed wall
Room height
Room dimensions
Room area
Living Room
32.0 ft
8.0 ft hea 1cool
18.0 x 13.0 a
234.0 W
Ty
Construction
number
U-value
�(BtutJft;°F%
I or
I H7M
(Btuh/ft2)
I Area UP)
or perimeter (ft)
I Load
(Bluh).
I Area
or perimeter
I Loatl
Heal
Cool
Gross
WP/S
Heal
Cool
Gross
WP/S
Heat
Cool
6
11
T
V
1---G
W
UII
L�-0G
C
F
13A-4ocs
4A5-2am _-. _ .
13A-4ocs
4A5-20m
11D0 _ _. -__ _
13A-0ocs . _- _ ._
13A-4om
4AS2am
11DO ,,.
16B-30ad _ __ __
22A-tpl
- 0.143
.0.770
0,143
0.770
0.390
_ ._._.
_ _. 0.143
0.770
0.770
_0.390-w-.
. 0.032
0.989
n
n
a
a
_ a
s
w
w
_- .
4.00
... 21.56
4.00
21.56
10.92
_. _- _
__ _ 4.00
4.56
21.56
10.92
__ 0.90
27.69
_
2.19
_19.31
2.19
47.10
10,34
.__ ._. _.-
-.__..2.19
2.10
47.70
10.34-_-._,20
_ .1.60
0.00
- 0
_._ ._ 0
8
0
0
___._ _ _
-..- 104
30
130
- ._ .234
234
0
_- . 0
8
0
____ 0
-_._ _ _.704
94
0
_ _20-_-,-223
— -
------234.
32
- 0
. ___. . 0
32
0
0
,_.., ...
___' 416
375
647
. _210
686
0
_ ..._ _ 0
18
0
0
�._ __.
_ ___.228
205
1413
413
___217
:..__ 374
0
__..
_.
--------
-.___...._..
_-
61
c) AED excursion
395
Envelope loss/gain
I
2789
2843
12
a) Infiltration
b) RoomvenWa0on
519
0
142
0
13
Internal gains: Occupants® 230
Applianceslother
2
460
900
Subtotal (lines 6 to 13)
3308
4345
14
15
Less external load
Less transfer
Redistrlbubon
Subtotal
Duclloans
27%
31%
0
0
0
3308
907
0
0
0
4345
1336
oad
Airt equ red (cfm)
I
4216I 15
5261I
Calculations approved by ACCA to meet all *requirements of Manual J 8th Ed.
/- wrrghtsot`e- 2019-May-1609:53.42
. P. Right Resid®U.rup a1em MJS,Fro Roorfac 1 Page
...HVAC\Gentile Corp - Moore - Jones Resitlence.mp CaIc=MJB Front Doorlaces: W
wrightsoftDuct System Summary
Entire House
Quick Calcs, Inc.
317 St. Lude Lane, Fort Pierce, FL 34946 Phone: 772466-6799 Ernst: quirkcelcs@aol.com
For: Gentile Corp. - Moore - Jones Residence
2604 Sterling Corurt, Fort Pierce, FL 34946
External static pressure
Pressure losses
Available static pressure
Supply / return available pressure
Lowest friction rate
Actual air flow
Total effective length (TEL)
Heating
0.50
in H2O
0
in H2O
0.50
in H2O
0.250 / 0.250
in H2O
0.310
in/100ft
967
cfm
161 ft
Job:
Date:
By:
Cooling
0.50
in H2O
0
in H2O
0.50
in H2O
0.250 / 0.250
in H2O
0.310
in/100ft
967
cfm
Name
Design
(Btuh)
Htg
(Cfm)
Clg
(Cfm)
Design
FR
Diam
(in)
H x W
(in)
Duct
Matl
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
Bath
h 732
38
16
0.311
5.0
OX 0
VIFX
25.7
135.0
st5
Bedroom 2
h 2931
151
128
0.361
8.0
OX 0
VIFx
23.4
115.0
st3
Bedroom 3
h 1820
93
72
0.389
7.0
OX 0
VIFX
13.5
115.0
st3
Bedroom 4
h 3108
160
119
0.310
8.0
OX 0
VIFx
26.3
135.0
sty
itchen
c 3634
56
167
0.397
8.0
Ox 0
VIFX
10.9
116.0
st2
Laundry
C 1318
44
61
0.397
6.0
Ox0
VIFx
10.9
115.0
st2
Living Room
c 2841
108
131
0.316
7.0
OX 0
VIFx
23.4
135.0
st4
Living Room -A
c 2841
108
131
0.3191
7.0
Ox 0
VIFx
21.8
135.0
st4
Master Bath
h 752
39
18
0.3891
5.0
OxO
VIFX
13.4
115.0
stl
Master Bedroom
h 3320
171
124
0.3921
8.0
Ox0
VIFx
12.5
115.0
stl
Trunk
Htg
Clg
Design
Veloc
Diam
H x W
Duct
Name
Type
(Cfm)
(Cfm)
FIR
(fpm)
(in)
(in)
Material
Trunk
st1
Peak AVF
209
142
0.389
473
9.0
0 x 0
VinlFlx
sty
Peak AVF
197
136
0.310
565
8.0
0 x 0
VinlFlx
st3
st3
Peak AVF
441
336
0.310
562
12.0
0 x 0
VinlFlx
st4
Peak AVF
216
261
0.316
591
9.0
0 x 0
VinIFIX
st2
st2
Peak AVF
316
489
0.316
623
12.0
0 x 0
VinlFlx
wHghtsoft- 2019-May-1609:53.42
.....-.�......, RightSuite® Universal 201919.0.01 RSU08101 Pagel
...HVAC1Gentile Corp - Moore -Jones Residence.mp Calc=MJB Front Doorfaces: W
Name
Grille
Size (in)
Htg
(dial
Clg
(cfm)
TEL
(ft)
Design
FIR
Veloc
(fpm)
Diam
(in)
H x W
(in)
Stud/Joist
Opening (in)
Duct
Mat[
Trunk
rbl
Ox0
967
967
0
0
0
0
Ox 0
VIFx
wrightsofi- 201SMay-1809:53A2
} �• .......�.�... Righl-Suite® Universal 201919.0.01 RSU08101 Page
Al.1+N...HVAC\Gentile Corp -Moore- Jones Resioence.rup Cale=MJ8 Fronl Doorfaces: W