HomeMy WebLinkAboutGROUND MOUNT PAPERWORKInverter Type: Solaredge PV Panel: (55) LG 320W Racking: Iron Ridge Total Wattage: 17,600W Mount Type: Ironridge ground rack Wind Load: 7 to 27 Deg Fastener Type: Concrete piers Sheet Index S-1 Cover Sheet / Site Plan S-2 Detail E-1 One - Line S-lA Mounting Plan General Notes: -(2) SolarEdge SE760OH-US Inverter located near utility meter -SolarEdge P320 Optimizers are located behind each module. -Wire run from array to connection is 60 feet. Godwin Engineering and Design, LLC 8378 Foxtail Loop Pensacola, FL 32526 D. Chad Godwin, PE Chad@godwineng.com i1, _Al, G-1 # Modules (55) Pitch: 250 Azimuth: 195' Utility Meter -COGEN Disconnc Located adjacent t( Utility meter -(2) SolarEdge SE7600H Inverter Legend Ground mount kept Chimney - at least 15 feet from street ® First responder access Satellite - at least 5 feet from utility easement Utility Meter o Vent Pipe ❑ PV Disconnect SolarEdge Inverter - at least 10 feet from property line 2017 FL Residential Code,6th Edition (2015 International Residential Code - 2nd Printing modified by the FL Building Standards and Codes 2017 Uniform Code Supplement), 2015 International Energy Conservation Code, County of St Lucie Code, 2014 National Electric Code. Customer Info: Norm O'Donnell 5541 Teal Terrace F tting R O N T X F H DR ONCE Q I"TY U S E 3-4" ige Based on Site Conditions t Home Services 9416 International Ct, St. Petersburg, FL 33716 844-778-8810 Date: 6.10.19 Drawn by: BC Fort Pierce, F&A(dNED Checked I 34982 By Rev #: 00 Stlucle?ft* Rev Date: S- V'I CROSS BRACE REQUIRED IRAL � i %' 8'-3" N edge T 25� clearance 6-8 2'-6" ABOVE . ACROSS BRACE ABOVE y S edge T 5'---8" BELOW clearance - — - — 5'-2� 5'-8" BE�ow -- - MINIMUM HOLE 6' I W DEPTH 1 9' _ N-S PIER SPACING 12"HOLE DIAMETER General Notes: -Racking is Secured to 14 - 6' Deep, I'Diameter Piers. @ 9' O.C. N-S using 3.5" O.D. Pipe 6. @ 10' O.C. E-W using 3.5" O.D. Pipe - 2.5 Cubic Yards of Concrete Q J' J. N-S PIER SPACING 9 J. s.IWL 'sa trnaE 40,m-_= 12'V4-m7PR saJo: Mllff FILM LLPAI POURM Ginve-WrO CGTGF_-7r ro eE 40M ps+ saz Config Repeats Total Piers South Piers North Piers Cross Pipes Total Pipe Length 5x11 1 14 7(8'-211) 7(12'-411) 2(61'-811) 268' Actual Quanities 7(241) 6(241) 312' Inverter Type: Solaredge PV Panel: (55) LG 320W Racking: Iron Ridge Total Wattage: 17,600W Mount Type: Ironridge ground rack Wind Load: 7 to 27 Deg Fastener Type: Concrete piers Customer Info: REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC Godwin Engineering and Design, LLC 8378 Foxtail Loop Pensacola, FL 32526 D. Chad Godwin, PE Chad@godwineng.com -:Z 0v� IEPoC. GO����i 8 = � � 360 _ 0 S ACE OF , c ►�`�(If V jm EH S Efficient Home Services 9416 International Ct, St. Petersburg, FL 33716 844-778-8810 Norm O'Donnell Date: 6.10.19 5541 Teal Terrace Drawn by: BC Fort Pierce, FL Checked by: 34982 Rev #: 00 Rev Date: Pate: S-2 1 2 3 o o 13 14 o 1 2 3 = _ 13 14 1 2 3 0 0 13 14 SolarEdge Power Optimizer (8) # 10 AWG Wire (1) #8 EGC In 3/4" EMT type or FMC,PVC, LFNC (depending on route to inv. Metal if interior) Inverter Output Ckt To Overcurrent Protection Device AC Max Output Current 32 AC Max Output Current * 1.25% 40 Overcurrent Protection A 40 No. of Current Carrying Cond <4 Conductor Gauge AWG 8 Combined Inverter Output Ckt AC Max Output Current 64 AC Max Output Current * 1.25% 80 Overcurrent Protection A 80 No. of Current Carrying Cond <4 Conductor Gauge AWG 4 In Case of Emergency Call Efficient Home Services at 844-778-8810 2J-Boles TIP Equipment list Pv: (55) LG 320W (55) SolarEdge Power Optimizer P-320 Inverter: (1) SolarEdge SE760OH-US (2) strings of (14) (1) SolarEdge SE760OH-US (1) string of (14) (I) -string -of (13) SolarEdge AC/DC Safety Switch Combiner: 125A Load Center AC Disconnect: 100A Fused Service Rated Disconnect All wiring to meet the 2014 NEC and 2015 Energy Code SolarEdge Inverter SolarEdge Inverter SE760OH-US-U SE760OH-US-U w/Integrated Disconnect w/Integrated Disconnect #8 LI,L2 Per Inverter #8 GEC & neutral In 3/4" Conduit Note: -All wiring to meet the 2014 NEC and Florida electric codes. 100A Fused Service Rated Disconnect -Type of conduit to be determined on site by contractor. Must be metal if DC ran interior. Line 125A Combiner /IOOA Service Fused Rated Disconnect Neutral to Ground Bond 80A La 2 Pole Circuit B. #4 LI,L2 & neutral #6 GEC In 1" Conduit Main Panels (2) 100A Main LI L2 N Tap M �r m (1)46AWG EGC & GEC #4 L1,L2 & neutral In I" Conduit Refer to NEC 312.8 Cor Conditions on taps in swi and over current devices Enclosures. If the wnditions are not met a tap boz will need to be instilled. GEC NOTES Provide a grounding electrode system for an ungrounded system per 690.47(C)(3). - GEC must be installed per 250.64 - GEC must be continuous un-spliced or irreversibly spliced from inverter to existing service ground system or continuous from the arrays to the existing service ground system. - If GEC is not continuous from the army to the existing service ground an additional ground system must be provided from the arrays to a grounding electrode per 690.47(D) - GEC must be min 48 AWG and installed in conduit Customer Info: EQUIPPED WITH RAPID SHUTDOWN LABEL PER NEC M SAC}PROVIDE AT NEW SUB PANEL OR SERVICE PANEL FOR RAPID SHUTDOWN COMPLIANT SERVICES PHOTOVOLTAIC SYSTEM DC DISCONNECT MAX POINT CURRENT: 50.28 A MAX POWER POINT VOLTAGE: 350 VDC MAX SYSTEM VOLTAGE: 480 DC MAX CIRCUIT CURRENT: 15 A ELECTRIC SHOCK HAZARD IF GROUND FAULT IS INDICATED ALL NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION A q X" 1 P IN.S : We) "A: GYJA [4 f, THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAYBE ENERGIZED WARNING DUAL POWER SUPPLY SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM Norm O'Donnell 5541 Teal Terrace Fort Pierce, FL 34982 REVIEWED FOR CODE COMPLIANCE ��' Isconnectrnv�e t Ty ®OCC Godwin Engineering and Design, LLC 8378 Foxtail Loop Pensacola, FL 32526 D. Chad Godwin, PE Chad@godwineng.com Date: Apply to Inverter Apply to Disconnects Apply to each J box, combiner box, disconnect,and device where energized, ungrounded circuits maybe exposed during service. Apply to MSP Apply to Disconnects NA j EH S Efficient Home Services 9416 International Ct, St. Petersburg, FL 33716 844-778-8810 I Rev Date: 6.10.19 BC E-1 LG325N1K-A5 I LG320WK-AS I LG315N1K-A5 - 325W ► 320W-I 315W The LG NeON® 2 is LG's best-selling solar module. The NeON® 2 received the acclaimed 2015 Intersolar AWARD for featuring LG's Cello Technology, which increases power output and reliability and makes the NeON® 2 one of ' the most powerful and versatile modules on the market. OVE 01n - C E Feature Enhanced Performance Warranty LG NeON® 2 has an enhanced performance warranty. The annual degradation has fallen from -0.6 %/yr to -0.5 %/yr. Even after 25 years, the cell guarantees 24 % more output than the previous LG NeONO 2 modules. a Aesthetics LG NeONO2 Black has been designed with aesthetics in mind, using thinner wires that appear all black at a distance. ISImproved Performance on Sunny Days LG NeON® 2 Black now performs better on sunny days, thanks to its improved temperature coefficient ®High Power Output Compared with previous models, the LG NeON® 2 Black has been designed to significantly enhance its output efficiency, thereby making it efficient even in limited space Outstanding Durability ® With its newly reinforced frame design, LG has extended the warranty of the NeONO 2 from 15 years to 25 years, including labor. In addition, LG NeONO 2 can endure a front load up to 6000 Pa, and a rear load up to 5400 Pa. luNear Zero LID (Light Induced Degradation) The n-type cells used in LG NeON® 2 have almost no boron. This leads to less LID (Light Induced Degradation) right after installation. LG NeON®2 Black CODE REVIEWED OMPLIANpTCVE LG325N1K-A5 I LG320N1K-AS I LG315NIK-AS LUGIE ems, a B®CiC Certifications and Warranty eoti&at rn ( IEC 61215, IEC 61730-11-2 UL 1703 IEC 61701(Sah mist warosion test) IEC 67716(Ammonia=n aon test) L509001 Marine FirePerfnrmaxe. Type 2(UL 1703) Fire Raring Class C (ULGORD C 1703.IEC 61730) (Produavar ty 25Tears I output Warranty of Pmax linearVdamanty •1)lnt =98%2)After l styaat IMiYV mwldegmda 3)86%IW25y Temperature Characteristics INM [•C] 45 t3 'Pai - -037 V. i[%PC] I%rc7. 41.27 f lsc IWCI 0.03 Characteristic Curves 1'otml•M T.mp.nme M Electrical Mwe1 • Madimum PPwer(P.) [W] 1 325 1 320 1 315 'MPp Vohage(Vmpp)_-_ M- 31] 333 329 MPP Canent([-W) [A). 9.65 962 9.58 ;openG=itvoltage(Voc) M 40.9 412 40.7 share Grout Curtent flsd fA1 10.23 1019 10.15 j Maximum Series Fuse Raeng '[A] 20 I PowerTolermxs _ I [ys]. 0—a3 • SR:(StaMMTeat CaMi6xtk radian 1000W/m', tell temperature 25 YAM 1.5 Tlvw pplatepavreroutpue ismeasur and demmined by W neernia aria saleaM ab m dixmre Flertrfrel Prnttarticc fNnrr+l Model 1G325N1K-A5 -W320MK-AS LG315N1k-A5 Maeimum Fbwer(Rnax) [w] 240 236 232 ;MPPVoltage(VmPP) M 31.2 30.8 304 ( MPPeursent(ImpP) [A] 7.69 7.67 7.63 Open Cmft Valmge(11m) M 38.1 38O 37.9 shomce kOnFent(lst) (A). 8.23 820 8.17 •NDCTRN ani OP arg Ce9T�.an SWWW.ambrenttengx m 20•r�w'vidsp N 1 Me Dimensions (nun / inch) I1I('j`Il1 i�g-I I f I d f n� tar 6 1 .� L •The drr mbetwren the tamerof tMmauntlig/9nandvg holes About US 1l bgn]es in198.o po agb6al NgpLamCp%vammnitdi,.apaeminria.ftna,iD. Nesolar ma UrialsM a, h2010. ed on cedar liyz asnJ In O= Dram Al tai upported by LG Gmaps vast¢xpedenre Nthe Semi-mnduttotlGO, [hmuzrry NM Na rbls WZNKsb2010.LG5olarsucce wlarAWM In 20 3D201° saiezreme marketwNshismwa lablein32toumresTheNeOM(p,etiaz MonoY.°NeONLNeON°i.NeON^28iFaAalwonthe "I,rtersotarAWAHD"in 2013,2m5 a,g2016. whkhdemonsmtes W Sobts lea4 innavaoan aM mmnitment mthebduvy. LG NamhAmAAasPWa neT. LG ElttvonbsUSA be LG 1000syMn Arx,Fn9le aff%W 07632 Life's Good ConratelgsoUrCA,e Produttspwflratiaaamnibje to chwe,awiftanotim O r O DS-N5-60-K-G-F-EN-80308 ®20181G Elechonics All rights reserved • Os�• wmvJgsobusatam Single Phase Inverter With H D-Wave Te:chlnotogy -for-Nortl. Arnerrca - - - - - SE30 j6H- US / SE3600H=US / SE5000H=US /SSE6000.H' S-_/ SE7600H "US IS E1:000OH -US % SE1140QH US . O: solar =- - T .,.ND—. -0000 - solar,�r �I` D_. O 6 0000 V ® O. O _ - Optimized installation with HD -Wave technology / Specifically designed to work with power optimizers / Record -breaking efficiency Fixed voltage inverter for longer strings / Extremely small CO G 0 1 / Built-in module -level monitoring Outdoor and indoor installation I h 4 i Integrated arc fault protection and rapid shutdown for / Optional: Revenue grade data, ANSI C12.20 NEC 2014 and 2017, per article 690.11 and 690.12 Class 0.5 (0.5% accuracy) / UL1741 SA certified, for CPUC Rule 21 grid compliance Z C Single Phase Inverter Wit HD -Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE1000OH -US / SE1140OH-US 111 60O 000O40O OUTPUT Rated AC Power Output 3000 3800 @ 240V 3300 @ 208V 5000 6000 0 240V 5000 @ 208V 7600 10000 11400 @ 240V 10000 @ 208V VA Maximum AC Power Output. _ _ _ 3000 - 3800 @ 240V —3300-@ 208V 5000 6000 @ 240V 5000 @ 208V 7600 10000 11400 @ 240V - 10000 0-208V- VA AC Output Voltage Min.-Nom.-Max. (211- 240 - 264) JREVIEWED ORS f9 Vac AC Output Voltage Min: Nom.-Max. - 208 - 229) _ _ CODE _ ��f? NICE W Mac AC Frequency (Nominal) 59.3 - 60 - 60.50 SM Hz Maximum Continuous Output Current@240V 125 16 21 25 32 ®O 2OO 47.5 A Maximum Continuous Output Current @208V - 16 - 24 - - 48.5 A GFDI Threshold 1 A Ublity Monitoring, Islanding Protection, Country Configurable Thresholds Yes ,INPUT;_ Maximum DC Power@240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V - 5100 1 - I T750 - - 15500 W Transformer -less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current @240VO 8.5 10.5 1 13.5 1 16.5 1 20 1 27 30.5 Adc Maximum Input Current @208VO - 9 1 - 1 13.5 1 - - 27 Adc Max. Input Short Circuit Current 45 Adc Reverse -Polarity Protection Yes Ground -Faun Isolation Detection 600ka Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 99 @ 240V 98.5 @ 208V % Nighttime Power Consumption 42.5 W _ADDITO—PPMOFEATURESt Supported Communication Interfaces RS485, Ethernet ZgBee (optional), Cellular (optional) Revenue Grade Data, ANSI C12.20 Optionalw Rapid Shutdown - NEC 2014 and 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect ,STANDARD6QMPLh`ANCE- - _ _ Safety UL1741, UL1741 SA, UL16998, CSA C22.2, Canadian AFCI according to TLL M-07 Grid Connection Standards IEEE1547, Rule 21, Rule 14 (Ho Emissions FCC Part 15 Class B INSTALLATION3PECIFICATIONS; . AC Output Conduit Size AWG Range 3/4'minimum/14-6AWG 3/4'minimum/14-4 AWG DC Input Conduit Size / # of Strings / AWG Range 3/4' minimum / 1-2 string / 14-6 AWG 3/4' minimum / 1-3 strings / 14-6 AWG Dimensions with Safety Switch (HxWxD) 17.7 x 14.6 x 6.8/ 450 x 370 x 174 213 x 14.6 x 7.3/ 540 x 370 x 185 in/ mm Weight with Safety Switch 22/10 1 25.1/11.4 1 26.2/11.9 38.8/17.6 Ib/kg Noise < 25 1 <50 dBA Cooling Natural Convection Operating Temperature Range -40 to +140 / -25 to +60 (-407 / -40'C option)w -F /'C Protection Rating NEMA 4X (Inverter with Safety Switch) " For other regional settings please contact SolarEdge support solar higher grade eIsourte may 6eused-IJS0Dverterwillfmli input current to the values sated a Revenue grade Inverter P/N: be used, the i 0NNQ solaredge.eom w For power de -rating infomlation refer tx https'lM wr.solamdge W Wsites/default/files/se-temperatue-denting-note m.pdf W -40 version PM: SExmH-US000NNU4 ® SdarEdge TeduWogies, Ix All dghesresemd. SOtARFDGE Ne SdaR49a Iaga.OPnMRED aVSOIAPFDGE are 4a0emabarregistered naaemarlo d SdarF4ge Tetivwlaglea, IKNI RoHS Power 0 timizer For North America 03201/ P340 /.P37.0;/-P400../,'P405./;P505. 31 PV power optimization at the module -level /• Specifically desigiied,to Work, With SolarEdge % Past installation With -a single bolt i'nvercers • Next generation maintenance wiifi mof ul'e-• / lJp to 25% more engrgy. level mo. hitoring, /' Superior -efficiency, (99.5b/o) / ;Mitigates all'types of module mismatch losses) from manufacturing tolerance to partial shading I 'fle'xible system design.for maxi ,mum space utilization / LM.eI requirements for arc fault protection'(AFCI).and Photovoltaic'Rapid Shutdown System(PVRSS) I Module-levei voltage:sfiutd(iwn for installer .and firefighter safety / Power Optimizer For North America - P320 / P340 / P370 / P400 / P405 / P505 Rated Input DC Powerw 320 1 340 370 400 405 505 W Absolute Maximum Input Voltage (V0c at lowest temperature) 48 60 80 1250 830 Vdc MPPT Operating Range 8-48 8-60 8-80 12.5-105 12.5-83 Vdc Maximum Short Circuit Current OX) 11 101 14 Adc Maximum DC Input Current 13.75 12.63 17.5 Adc Maximum Efficlency 99.5 % Weighted Efficiency 98.8 98.6 % Civervoltage Category II Maximum Allowed System Voltage 1000 Vdc Compatible Inverters All SolarEdge Single Phase and Three Phase Inverters Dimensions (W x L x H) 129 x 153 x 27.5/ 5.1 x 6 x 1.1 129x 153 x 33.5/ 5.1x6x1.3 129x159 x 49.5/ 5.1x63 x1.9 129 x162 x 59/ 5.1 x 6,4 x 2.3 ram/in Weight(induding cables) 630/1.4 1 750/1.7 1 845/1.9 1064/2.3 gr/Ib Input Connector MCP Output Wire Type / Connector Double Insulated; MC4 Ougwt wire Length 0.95/3.0 12/3.9 m/ft Input Wire length 0.16 / 0.52 m / ft Operating Temperature Range -40 - +85 /-40 - +185 -C / -F Protection Rating IP68 / NEMA6P Relative Humidity 0 -100 % n Rated STC powerorthe module. Module of up m.5%pavermlexen aIIwrd w NEC 20I7 requires max Input voltage be not more than 80V m For other connector types please contact SolarEdge Minimum String Length (Power Optimizers) 8 1 10 1 18 25 25 1 SOX Maximum Power per String I SE7600-US-SE71400- I 52SU 1 60000 1 12750m I W , ... -.....a .................. -....y...- or Oridentations Yes N For detailed string sieng Information refer V. haplMwxsdamdge.cowsmwdefault/files/Arirx mrxi-na Of m it Is riot allowed W m4 P405/PWS with P320/P340/P370/P400 in one string m A string with move than 30 optimizers does not meet NEC rapid shutdown requirements; safely volmga,.0 be above the 30V requiremart m For SE14.4KUS/SE43.2KUS: It Is alloved to Install up w 6.50DW per string when 3 strhgs are connected Wthe irwrter (3 strings per unit for SE43.2KUg and when the maximum power df(etence beween the O gs Is up to t000W m For SE30KU5/SE333WSAE66.6KU5/SE100KUS. his allwmd to install up 15,000W per wing when 3 strings are connected W the Inverter (3 strings per unit for SE66.6K11S/SMWIOJ5) and when the maximum power di8ewo, between the saints is up to 2,000W solaredge.com so l a r • O SdaF4gaT Tndogief Ll6MdgtN rtunrtd601AlIFDGe NeSOIVEEgelag4rtl•IP.�pBfSdACFDGE art hrademaA, urrtgl,.ertlbtl<mW OISohRdga Tedv s, lnc ah CE RoHS advnexemmltr m.�a� a Iwrcn aie eaannatxdudr rmPam.awnw: mheu7mae/wUFrve wv4wgeem dxxgewlhlnutwta. �. IRONRIDGE Solar is Not Always Sunny Over their lifetime, solar panels experience countless extreme weather events. Not just the worst storms in years, but the worst storms in 40 years. High winds capable of ripping panels from a roof, and snowfalls weighing enough to buckle a panel frame. ',% 'XR Rails are the structural backbone preventing these results. They resist uplift, protect ,against buckling and safely and efficiently F transfer loads into the building structure. Their superior spanning capability requires fewer roof attachments,r . reducing the number of roof penetrations and the amount�- of installation time. ' XR Rail Family e i `'•a' }r i7 r= Force -Stabilizing Curve r..,e Sloped roois generate both vertical and lateral _ forces on mounting rails which can cause them to bend and twist. The curved shape of XR Rails is specialty designed to increase strength in both directions while resisting the twisting. This unique feature ensures greater security during extreme j<y weather and a longer system lifetime. Compatible with Flat & Pitched Roofs XR Rails are IronRidge offers compatible with a range of tih leg FlashFoot and options for flat I other pitched roof ■fill! roof mounting attachments. applications. Corrosion -Resistant Materials All XR Rails are made of 6000-sedes -rt, l�`I aluminum alloy, then protected with an '„` anodized finish. Anodizing prevents surface and structural corrosion, while also providing Y a more attractive appearance. w�r XR Rail Family aq'' + `i� a•� i H 1l, The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads, while minimizing material costs. Depending on your location, there is an XR Rail to match. XR10 XR10 is a sleek, low -profile mounting rail, designed for regions with light or no snow. It achieves 6 foot spans, while remaining light and economical. • 6'spanningcapability • Moderate load capability • Clear & black anodized finish • Internal splices available XR100 XR100 is the ultimate residential mounting rail. It supports a range of wind and snow conditions, while also maximizing spans up to 8 feet. • 8'spanning capability • Heavy load capability • Clear & black anodized finish • Internal splices available XR1000 Is a heavyweight among solar mounting rails. U's built to handle extreme climates and spans 12 feet or more for commercial applications. 12'spanning capability Extreme load capability Clear anodized finish Internal splices available Rail Selection REVIEWED FOR CODE COMPLIANCE The following table was prepared in compliance with applicable engrArirQg alQ5talitl2rtls' Values are based on the following criteria: ASCE 7-10, Roof Zone 1, Exposure B, Roof SleMCYQ 27 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed span tables and certifications. Load. _ Aall _I Span 3 LSnow•(?S�) ,I `WLndJ(MPH)..I' 4r I 9+°4°a I; ;y 110'- I 1.2r 11 1 11 Ir1 IF i 1 1 i 11 1 i� 1