Loading...
HomeMy WebLinkAboutEVALUATION REPORT0 ENGINEER EVALUATE Polyglass USA, Inc. 150 Lyon Drive Fernley, NV 89408 (954)233-1330 NEMO l etc.SCANNEDCertlifimte of Authorization#32455 BY 353 Christian Street, Unit #13 St. Lucie County Oxford, CT 06478 (203)262-9245 TEST CONSULT CERTIFY Evaluation Report P9290.02.08-R21 FL1654-R23 Date of Issuance: 02/11/2008 Revision 21:10/08/2018 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Polyglass SBS and APP Modified Bitumen Roof Systems LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO [etc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOIetc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 4, plus a 65-page Appendix. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 CERTIFICATION OF INDEPENDENCE: a ocQ:cixap.o�•.. x s�s 39 'E'D:JW"Jim ,- �'+:Fc ;�.�•�'++ F :..erg �• The facsimile seals appearing was authorized Robert PP g Y •; ���� �?�u+°". Nieminen,P.E an 10/08/2038. This does not serve as an ' electronically signed document 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ONEMOletc. ROOFING SYSTEMS EVALUATION: Product Category: Roofing Sub -Category: .Modified Bitumen Roof Systems Compliance Statement: Polyglass SBS and APP Modified Bitumen Roof Systems, as produced by Polyglass USA, Inc., have demonstrated compliance with the following sections of the 6Lh Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. Section- _ _ _ Property_ _ _ _ _-- _ Standard _ _ _ _ _- _- Year 1504.3.1 Wind FM 4474 2011 1504.3.1 Wind UL 1897 2012 1504.7 Impact FM 4470 2012 1507.11.2 Physicals ASTM D6162 2008 1507.11.2 Physicals ASTM D6163 2008 1507.11.2 Physicals ASTM D6164 2011 1507.11.2 Physicals ASTM D6222 2011 1507.11.2 Physicals ASTM D6509 2009 Entity Reference Date _ Entity _ Exam _ Reference _Date ERD (M6649) __Exam_ Physicals _ ___ P10490.10.08-2 10/30/2008 FM (TST3867). FM 4470 200AOAM 12/23/1998 ERD (TST6049) FM 4470/4474 P33760.09.09 09/10/2009 FM (rST1867) FM 4470 205A9.AM 06/22/1999 ERD (TST6049) FM 4470/4474 P13770.09.09 09/10/2009 FM M1867) FM 4470 3006646 01/04/2WO ERD (TST6049) FM 4470/4474 P30540.11.09-111 11/30/2009 FM p5T1867) FM 4470 3W1334 01/25/2000 ERD Cl` TGo49) FM M70/4474 P30550.32.09 12/02/2009 FM (5r1867) FM 4470 3MI334 OV15/2000 ERD(TST6049) Physicals P33968.12.10 12/30/2010 FM(r5T1857) FM 4470 3MM57 01/12/2000 ERD(TST6049) FM 4470/4474 P33970.03.11 03/15/2011 FM(TST3867) FM 4470 3004091 01/12/2000 ERD 051­6049) Physicals P37590.03.13-3A 03/06/2013 FM(TST3867) FM 4470 30D6115 05/02/2001 ERD(TST6049) FM 4470/4474 P39680.03.13 03/04/2013 FM(TST1867) FM 4470 3012321 07/29/2002 ERD W6049) Physicals M7590.03.13-1-RI 06/26/2013 FM RST3867) FM 4470 3014692 08/05/2GO3 ERD(TST6D49) Physicals M7590.03.13-2-RI 07/01/2013 FM(rST1867) FM 4470 3014751 08/27/2OD3 ERD (TST6049) Physicals P37590.07.13-2 07/01/2013 FM (TST1867) FM 4470 3W7170 01/13/2004 ERD ITS1`6049) Physicals M7590.03.13-5-RI 07/01/2013 FM (1`51`1867) FM 4470 3019317 06/30/2004 ERD(TST6049) Physicals P37590.07.13-1 07/02/2013 FM UST1867) FM 4470 3020703 07/30/2DO4 ERD (TST6049) FM 4470/4474 P41630.08.13 08/06/2013 FM (TSr1867) FM 4470/4474 3018332 01/31/2006 ERD (TST6049) Physicals P45940.09.13 09/04/2013 FM(1`51`3867) FM 4470/4474 3023368 03/20/2006 ERD maiso49) Physicals P44370.10.13 10/04/2023 FM(TST1867) FM 4470/4474 3024594 05/23/2006 ERD(TST6049) Physicals P39520.09.14-2 09/11/2014 FM RST1867) FM 4470/4474 3023458 07/18/2006 ERD(TST6649) FM 4470/4474 SC6160.11.14 12/10/2014 FM(TSr1867) FM 4470/4474 3030668 09/12/2007 ERD (TST6049) Physicals P454MSC03.15-1 03/31/2015 FM R51­1867) FM 4470/4474 3032172 06/12/2009 ERD(TST&D49) Physicals SC5170.05AS 05/08/2015 FM(rST1867) FM 4470/4474 3049631 04/21/2014 ERD (TST6049). FM 4474 SC8085.05.15 05/19/2015 FM RST1867) FM 4470/4474 3057029 02/02/2017 ERD(TST6D49) Physicals SC5170.12.15 12/29/2015 NEMO W6049) Criticality 45-0LYG-18401.06.18 06/23/2018 ERD(TST6049) FM 4470/4474 SC9455.15 04/01/2016 NEMO(TS Moss) FM U74 41.-KY45-18-003.08.13 08/21/2018 ERD W6049) FM 4470/4474 PLYG-SC8905.05.16-1 05/17/2016 NEMO (TST6049) FM 4474 PLYG4CLC3,L4,C5,r8 09/21/2018 ERD(TSr6049) FM 4470/4474 PLYG-SC8905.05.16-2 05/17/2016 NEMO(IST6049) Criticality 4iPLYG-I8a01.10.18 10/03/2018 ERD(TST6D49) FM 4470/4474 PLYG-sc10815.07.16-R3 09/23/2016 PRI(rST5878) Physicals PUSH-062-02-01 12/04/2007 ERD(TST6049) UL1897 PLYG-SC12025.10.16 10/12/2016 PRI(rST5878) Physicals PUSA-061-02-02 01/28/2008 ERD (TST6049) FM 4470/4474 PLYG.SC11475.16 11/17/2016 Pat(TST5878) Physicals PUSH-06 02-02 02/27/2008 ERD ITST6049) FM 4470/4474 PLYG-SC13235.01.17 01/17/2017 PRI (rSr5878) Physicals PUSH-062-02-02 12/04/2008 ERD (TST6049) FM 4470/4474 PLYG-SC13920.05.17 05/30/2017 PRI (TST5878) TAS 114 PUSH-188-02-01 02/08/2017 ERD ITS1`11294) FM 4470/4474 PlYG40113945.05.17.1 05/30/2017 PRI(TSr5878) TAS 114 PUSH-188-02-02 02/08/2017 ERD (TST11294) FM 4470/4474 PLYG{ 3945.05.17.3 05/30/2017 PRI (TST5878) TAS 114 PUSA-188-02-03 02/08/2017 ERD (TST6D49) FM 4470/4474 PLYG-SC33945.05.17 05/30/2017 PRI (TST5878) TAS 114 PUSH-202-02-01 05/17/2017 ERD CW6D49) FM 4470/4474 PLYG-SCI5760.09.17 09/11/2017 PRI RST5878) TAS 114 PUSH-202-02-02 05/17/2017 FM rW1867) FM 4470 2W7A7AM 08/04/1994 M-D(CERI592) HVHZ Various NOAs Various FM(TST1867) FM 4470 OU3A3AM D4/04/1997 M-D(CER1592) Prop. for Rev. IG-0823 10/12/2010 UL(QUA9625) Quality Control Service Confirm 0113/2018 NEMO ETC, LLC Evaluation Report P9290.02.08-R21 Certificate of Authonration#32455 6-EDITION (2017) FBC NON-HVHZ EVALUATION FL1654-RZ3 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 21: 10/08/2018 Page 2 of 4 NNEMOletc. This Evaluation Report covers Polyglass Modified Bitumen Roof Systems installed in accordance with Polyglass USA, Inc. published installation instructions and the Limitations / Conditions of Use herein. The following Polyglass membranes make up the subject systems. TABLE T Type 1: ROLL -GOODS FOR POLYGLASS MODIFIED BITUMEN Product ROOF SYSTEMS -. Specification Reference Grade Type Base Sheets Polyglass G2 Base ASTM D4601 N/A II Polyflex SA Base ASTM B4601 N/A II Polyglass APP Base ASTM D6509 N/A N/A SBS Membranes Polyglass HT Base 650 ASTM D6162 S III Elastobase ASTM D6163 S I Elastoflex V ASTM D6163 5 1 Elastoflex SA V Base ASTM D6163, Table 2 5 I Elastoflex SA V FR Base ASTM D6163, Table 2 S I Elastoflex SA V Plus ASTM D6163 S I Elastoflex SA V Pius FR ASTM D6163 S I Eiastobase Poly ASTM D6164 S I Elastoflex56 ASTM D6164 S I Elastoflex 56 Type II ASTM D6164 S II Elastoflex VG ASTM D6163 G I Elastoflex VG FR ASTM D6163 G I SBS Membranes Elastoflex S6 G ASTM D6164 G 1 Elastoflex S6 G FR ASTM D6164 G I Polyfresko G SBS (sand or poly -film back) ASTM D6164 G I Polyfresko G SBS FR (sand or poly -film back) ASTM D6164 G I Elastoshield TS G ASTM D6164 G I Elastoshield TS G FR ASTM D6164 G I Elastoflex SA P ASTM D6164 G I Elastoflex SA P FR ASTM D6164 G I Polyreflect ASTM D6164 S I APP Membranes Polyflex ASTM D6222 S I Polyflex G ASTM D6222 G I Polyflex G FR ASTM D6222 G 1 Polyfresko G ASTM D6222 G I Polyfresko G FR ASTM D6222 G I Polybond ASTM D6222 5 1 Polybond G ASTM D6222 G I Polyflex SA P ASTM D6222 G 1 Polyflex SA P FR ASTM D6222 G 1 Polyfresko G SA ASTM D6222 G I Polykool ASTM D6222 S I 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Refer to a current Approved Roofing Materials Directory for fire ratings of this product. 5.4 For steel deck installations, foam plastic insulation shall be separated from the building interior in accordance with FBC2603.4 unless the exceptions stated in FBC 2603.4.1 and 2603.6 apply. NEW ETC, LLC Evaluation Report P9290.02.08-R21 Certficate of Authorization#32455 6- EDITI ON(2017) FBC NO N-HVHZ EVALUATION FL1654-R23 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 21: 10/08/2018 Page 3 of 4 NNEMOletc. 5.5 The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5.6 For recover installations, the existing roof shall be examined in accordance with FBC 1511. 5.7 For mechanically attached insulation or membrane or strip -bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WDS, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5.8 For assemblies with all components fully bonded in place, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 5.9 For mechanically attached insulation or membrane over existing roof decks, fasteners shall be tested in the existing deck for withdrawal resistance. Aqualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 5.10 For bonded insulation or membrane over existing substrates in a re -roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance with ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124 shall be conducted on mock-ups of the proposed new roof assembly. 5.11 For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 5.12 Metal edge attachment (except gutters), shall be designed and installed for wind loads in accordance with FBC Chapter 16 and tested for resistance in accordance with ANSI/SPRI ES-1 or Roofing Application Standard RAS 111, except the basic wind speed shall be determined from FBC Figure 1609.3(i), 1609.3(2) or 1609.3(3). 5.13 All products in the roof assembly shall have quality assurance in accordance with FAC Rule 611320-3. 6.1 Polyglass Modified Bitumen Roof Systems shall be installed in accordance with Polyglass USA, Inc. published installation instructions, subject to the Limitations / Conditions of Use noted herein. 6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609for determination of design wind loads. As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS:" Contact the noted CIA agency for information on product locations covered for F.A.C. Rule 61G20-3 CIA requirements 9. QUALITY ASSURANCE ENTITY: UL LLC—QUA9625; (314) 578-3406, k.chancellor@us.ul.com - THE 65-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT - NEMO ETC, LLC Evaluation Report P9290.02.08-1121 Certificate of Authoriration#32455 6- EDITION (2017) FBC NO N-HVHZ EVALUATION FL1654-RZ3 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 21: 10/08/2018 Page 4 of 4 NNEMOjetc. APPLICATION TYPE DESCRIPTION PAGE TABLE DECK SA Wood New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 5 1B Wood New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 5-9 1C Wood New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 10-11 1D Wood New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 12 1E Wood New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 12-14 1F Wood New, Reroof (Tear -Off) or Recover D Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 15-17 1G Wood New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet (nails), Bonded Roof Cover 18-21 SH Wood New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet (screws & plates), Bonded Roof Cover 21-25 11 Wood New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 26 2A Steel or Structural concrete New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Tap Insulation, Bonded Roof Cover 27-29 2B Steel or Structural concrete New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 30-34 2C Steel or Structural concrete New, Reroof (Tear -Off) or Recover D Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 35-37 3A Structural concrete New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 38-46 3B Structural concrete New or Reroof(Tear-Off) F Non -Insulated, Bonded Roof Cover 46 4A Lightweight concrete New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 47-49 4B Lightweight concrete New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 50 4C Lightweight concrete New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 51-53 5A Cementltl0u5 wood fiber New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 54 5B Cementitious wood fiber New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 55 SC Cementitious wood fiber New, Reroof (Tear -Oft) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 56 SO Cementitious wood fiber New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 56 5E Cementitious wood fiber New, Reroof (Tear -Off) or. Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 56 6A Existing gypsum Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 57-59 6B Existing gypsum Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 59 6C Existing gypsum Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 60 6D Existing gypsum Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 60 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 61-65 7B Various Recover F Non -Insulated, Bonded Base Sheet, Bonded Roof Cover 65 The following notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement: ➢Wood: Minimum 0.75-inch penetration. ➢ Steel: Minimum 0.75-Inch penetration and engage the top flute of the steel deck. ➢ Structural concrete: Minimum 1-Inch embedment Into pilot hole in accordance with fastener manufacturer's published Installation Instructions. NEMO ETC, LLC Evaluation Report P9290.02.08-R21 for FU654-R23 Certificate of Authorization #32455 0 EDITION (2017) FBC NON-HVH2 EVALUATION Revision 21: 10/08/2018 Prepared by: Robert Merriman, PE-59166 Polyglass Modified Bitumen Roof Systems, (954) 233-1330 Appendix 1, Page 1 of 65 ONE'Mletc. 3. Unless otherwise noted, insulation maybe anyone layer or combination of polyisocyanurate,polystyrene, wood fiberboard, perlite,gypsum-based roof board or mineral -wool roof board that meets the CIA requirements of F.A.C. Rule 61G20-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when installed with the roof cover. 4. Minimum 200 psi, minimum 2-inch thick lightweight insulating concrete maybe substituted for rigid insulation board for System Type D (me chanically attached base sheet, bonded roof cover), whereby the base sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. S. Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (January 2016). 6. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer's published instructions. ➢ Hot asphalt (HA): Full coverage at 25-30lbs/square. _ D Dow INSTA STIK Ouik Set Insulation Adhesive (D-I5): Continuous 0.75 to 1-inch wide ribbons,12-inch o.c. D Millennium One Step Foamable Adhesive (M-OSFA): Continuous 0.25 to 0.5-Inch wide ribbons, 12-inch o.c. ➢ Millennium PG-1 Pump Grade Adhesive (M-PG3): Continuous 0.25 to 0.5-inch wide ribbons, 12-Inch o.c. D OMG OlyBond 500 (OB500): Continuous 0.75 to 1-Inch wide ribbons, 12-Inch o.c. (PaceCart or SpotShot). Note: OlyBond Green may be used where OlyBond 500 is referenced. D OlyBond Classic (OB Classic): Full coverage at 1 gal/square. D ICP Adhesive & Sealants Polyset CR-20: Continuous 2.5-3.5-Inch wide ribbons, 12-Inch o.c. D Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon -applied adhesive, board joints shall be staggered. D Note. The maximum edge distance from the adhesive ribbon to the edge of the Insulation board shall be not less than one-half the specified ribbons spacing. 7. Unless otherwise noted, all insulations are flat -stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure (MDP) limitations. In no case shall these values be used to 'Increase' the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed fora particular system in the tables, then the thinner board listed below may be used as a drop -in for the equivalent thicker material listed in the table: D Millennium One Step Foamable Adhesive (M-OSFA): MDP -157.5 psf (Min. 0.5-Inch thick) D Millennium PG-1 Pump Grade Adhesive (M-PG1): MDP -157.5 psf (Min. 0.5-inch thick) D OMG OlyBond 500 (OB500): MDP -45.0 psf (Min. 0.5-inch thick Multi -Max FA-3) ➢ OMG OlyBond 500 (08500): MDP -187.5 psf (Min. 0.5-Inch thick ISO 95+ GL) ➢ OMG OlyBond 500 (OB500): MDP -315.0 psf (Min. 0.5-inch thick ENRGY 3) ➢ OMG OlyBond 500 (OB500): MDP -487.5 psf (Min. 0.5-Inch thick ACFoam II) D ICP Adhesives & Sealants Polyset CR-20: MDP -117.5 psf (Min. 1.0-Inch thick) 8. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft. 9. For mechanically attached components or partially bonded Insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resistthe elevated pressure criteria. Commonly used methods are ANSI/SPRI WD3, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk` carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 10. For fully bonded assemblies, the maximum design pressure forthe selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis is permitted. 11. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 12. For existing substrates Ina bonded recover or re -roof Installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive, and the existing roof system (for recover) shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 13. For Recover Applications using System Type D, the insulation is optional; however, the existing roof system shall be suitable fora recover application. NEMO ETC, LLC Evaluation Report P9290.02.08-R21 for F11654-RZ3 Certificate of Authorization #32455 6m EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 10/08/2018 Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 2 of 65 ONEMOjetc. TABLE If: WOOD DECKS —NEW CONSTRUCTION OR REROOF(TIAR-OFF) SYSTEM TYPE F: NO N-INSU LATE .BONDED ROOF System peck (Nate 1) Primer Roof Cover (Note 15) MBP (psFl Joint Treatment Base Ply Ply Cap Ply No. APA rated, 7116 OSB joints are covered with 4-Inch wide strips of Elastoflex SA V, rolled into place to Elastoflex SA V Plus a (Optional)SBS-SA, SOS- SBS-SA, APP-SA,SBS- -$2.5 W-363 CAT, 0.418 None create continuous bond. Elastoflex SA V Plus FR TA,APP-TA TA,APP-TA Exposure 1O, Exposure 1 OSB W-183 Min. 15/32-Inch None None SBS-SA (Optional) SBS-SA, SBS- SBS-SA, APP-SA,SBS- plywood TA,APP-TA TA,APP-TA _ ex - Bona - IQ W-185 Min. 15/32-Inch PG100 None SBS-SA (Optional)SBS-SA, SBS- SBS-SA, APP-SA,SBS- -97.5 plywood TA, APP-TA TA,APP-TA Min. 15/32-Inch Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus, rolled into Elastoflex SA Va (Optional)SBS-SA, SBS- SBS-SA, APP-SA'SBS- 975 W-186 plywood (Optional) PG100 place to create continuous bond. Elastoflex SA V FR TA,APP-TA TA,APP-TA W-187 Min. 15/32-inch POLVBRITE 745 or None SBS-SA (Optional)SBS-SA, SBS- (Optional) SBS-SA, APP-SA,SBS- -105.0 plywood WB3000 TA, APP-TA Min. 15/32-Inch Plywood joints are covered with 44nch wide strips of Elastoflex SA V Plus, rolled into Elastoflex SA V Plus a (Optional)5B5-SA, SBS- SBS-SA, APP-SA, SBS- 1350 W-188 plywood (Optional)PG300 place to create continuous hood. Elastoflex SA Plus FR TA,APP-TA TA, APP-TA W189 Min. 15/32-Inch (Optional)PG300 Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus, rolled into Polyflex SA Base (Optional)APP-TA APP-TA -135.0 plywood place to create continuous bond. NEMO ETC, LLC Evaluation Report P9290.02.08-R22 for FL1654-RZ4 Certificate of Authorization #32455 6" r EDITION (2017) FBC NON-HVHZ EVALUATION Revision 22: 04/11/2019 Prepared by: Robert Nleminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (954) 733-1330 Appendix 1, Page 29 of 69