HomeMy WebLinkAboutPLANSmy 'AFF-MR115
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11651.12
26 ga. 5v crimp metal roofing attached to plgwood deck using 99 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(tgpe 2) 30 lb felt underlagment installed with min. 4' side laps and L" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
aced V o.c. at all laps and two staggered rows 12" o.c. in field. Attach
atilt Yn Yrivana iIainn nY.Y.nnl,manY ilaY ai tin 41.ia a1.amY
2°
a°
O c thick light textured
stucco on typical concrete
block construction
or
\ 5/8" thick x 8"w cut/
coral finished stucco bands
LEFT ELEVATION.
SCALE. 1/4" = 1'-0"
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11651.12
24 ga. 5v crimp metal roofing attached to plywood deck uaing #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(tgpe 23 30 lb felt underlagment installed with min. 4' side laps and L" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced L" o.c. at all laps and two staggered rows 12" o.c. in field. Attach
dock to trusses using attachment detail on this sheet
Finish Columns with >
5/8" thick cut coral
finished stucco bands
ELE\/ATION NOTES:
Gulf Coast Supplg and MFG 5v Crimp Metal roofing FL #II651.12
26 ga. 5v crimp metal roofing attached to plgwood deck using 49 x 1.5"
wood screws with self sealing washer at 12" ox. max spacing over ASTM D
(tgpe 2) 30 lb felt underlagment installed with min. 4' side laps and L" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced L" o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet
thick light textured
stucco on typical concrete
block construction
REAR ELEVATION
— Overhangs at 1'-0" unless otherwise noted on Roof Plan
— Roof pitch at 4:12 unless otherwise noted
— Ang changes to this plan shall be submitted to the architect
for approval in writing prior to starting construction.
— Return ALL Stucco Bands Into Window or Door.
12
SLOPE 14
5/8" thick x 8"w cut
coral finished stucco bands
3
�5/8" thick light textured
stucco on typical concrete
block construction
--------------------------------------------------------------
RIGHT ELEVATION
SCALE: 1/4" - 1'-0"
2" x 4" top plate
base —board
a
5/8" thick x 8"w cut
coral finished stucco bands
-0" — Finished Floor rft Finish Columns with
5/8" thick cut coral
finished stucco bands
1/2" drgwall ceiling on truss bottom cord
I/2" drgwall on
2" x 4" studs at 14" o.c.
2" x 4" P.T. bottom plate
\ 4" concrete slab with fibermesh OR
6"XL" #10/10 WWM on 6 mil Visqueen over
clean compacted termite treated fill
Interior Non —Bearing Partition
nts
12
SLOPE 4
Finish Columns with
5/8" thick cut coral
finished stucco bands
SCALE: 1/4" - I'-ii"
Gulf Coast Supplg and MFG 5v Crimp Metal roofing FL #11651.12
26 ga. 5v crimp metal roofing attached to plgwood -deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM O
(type 2) 30 lb felt underlagment installed with min. 4' side laps and L" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6" o.c. at all laps and two staggered rows 12" o.c, in field. Attach
deck to trusses using attachment detail on this sheet
5/8" thick light textured
stucco on typical concrete
block construction
F�V14 IED FOR
CODE COMPLIANCE
ST. LUCIE COU TY
BOCCI
1/8" Thick cut coral stucco over paper
backed wire lath nailed to substrate through
one layer of 15 lb felt using 8d nails. Substrate
to be 19/32" COX Plywood nailed at L" o.c.
in field and edges with IOd ring shank galvanized
nails into truss webbing.
12
SLOPE 14
FRONT ELEVATION
SCALE: 1/4" - 1'-0"
y
--- 5/8" thick x 8"w cut
coral finished stucco bands
ALL CONTRACTOR WARRANTIES BEGIN WHEN THE CLOSING
OCCURS BETWEEN THE BUYER AND WYNNE BUILDING CORP.
AND WILL CONTINUE FOR ONE YEAR FROM THAT DATE
PERMITTING INFORMATION (FORM 100)
Florida Building Code Residential: 6th Edition and ASCE 1-10 for Wind Loading
Building Design is: Enclosed Risk Categorg: If Wind Velocitg: 145 mph ultimate
Mean Roof Height: II' -On Roof Pitch: 4:12
Internal Pressure went: to -is
Subjectabilitg to damage from: Weathering. Negligible Termites:Veru Heavu
Width of Roof End Zone: 3'-4" Wind Speed: 165 mph ultimate
Wind Exposure Classification. C 1.21 x O.6 = 0.12G
Adjustment factor for Exposure Height: ASD design
Load Combination: ASCE 1-10 Section 2A DL+LL; DL+O.GWL; O.6DL+O.LIAL
Components t Cladding Wind Pressure (NET) Roof Zone: I. +20.6/-2.L pat
Rod Zone: 2. +20.4/- 1.0 pat
Roof Zone: 3. +20.6/-84.0 pat
Components k Cladding Wall End Zone Width: 3'_4"
Components t Cladding Wind Pressure (NET) Wall Zone: 4. +35.8/-38.1 pat
Wall Zone: 5. +35.8/-41.8 pat
Components t Cladding Wind Pressure (NET) on Garage Door: +32.0/-40.3 per
Shear Walls Considered for Structure? Yes
Continuous Load Path Provided? yes
Are Components an Cladding Details Provided? Yes
Minimum Soil Bearing Pressure:2,500 pa. Presumptive: X Bg Test: psi
This Building Shall Have the Following:
APPROVED SHUTTERS: X IMPACT GLASS: BOTH: NEITHER:
ROOF LIVE LOAD: 31 pat ROOF DEAD LOAD: 10 pat
FLOOR LIVE LOAD: 46 nsf FLOOR DEAD LOAD: 10 nsf
JOB ADDRESS:'-�a c,
TOROOF
M Pr rrH
0 = Roof Zone I
Wells Zone 4
EM - Roof Zone 2
Walls Zone 5
END ZONE
Corner Zones
Roof Zone 3
FLOOR PLAN
I� CRASH POST DETAIL
TYPICAL NOTES: SCALE 1/4" = i'-o" N.T.S.
I. Contractor to verify ALL notes and dimensions prior to steel
high by 4" diameter
steel crash post. Floor
proceeding with work. Flange with 4 - 3/8"
2. Contractor to STRICTLY enforce ALL OSHA Requirements. expansion ,bolts into
3. ALL Lumber to be used as Beam, Rafters, etc... to have aleb (3/8't 5o kal steel plate)
a minimum 1,400 F.S.I. fiber stress. `"'211
4. No dissimilar metals to touch. 2'r," 2;s"
5. ALL Concrete used for slabs shall be min. 2,500 PSi concrete. %"
ALL Concrete used for vertical filled cells, cont. tie beams etc.. to
shall be 3,000 P.S.I. concrete and/or 4,000 P.S.I. grout mix "3/8" ° 2/%
6. Drywall at ceilings shall be leveled and attached to bottom chord
of trusses with screws per FBC R102.3.5. ° 0 2/'
-i. ALL wood in contact with concrete shall be pressure treated.
8. ALL wall dimensions are nominal and not finished wall or stud dimensions.
9. ALL plumbing fixtures to be low flow.
10. Contractor to Provide Drain at water heater in accordance
with the current edition of the Florida Plumbing Code.
11. Contractor to Provide a 2'-8" wide door at one bathroom for 2',c"" 2�J"
handicap accessibility requirements.•
12. Lowest finished floor to be set bg Governing Building Department
surveyor to set in field.
13. Separation between residence and garage shall be per FBC R302.4
14. Door between garage and residence shall be 1-3/4"t 20 min. rated door
Water Heater
15. Wall and Ceiling shall have a flame -spread classification of not greater than 200 er FBC R302.9.1
16. Wall and ceiling finishes shall have a smoke -developed index of not greater than 450 per FBC R302.9.2
11. All exposed attic insulation materials installed on attic floors shall have a critical radiant I" x 6" P.T. Buck Waded to Masonry Beam
flux not less than 0.12 Watt per square centimeter. Exposed foam plastic insulation block with case hardened nails
materials exposed on the underside of the roof deck or on the attic walls shall comply prior to door attachmen
- edition
with 316 see permit info box of code
P.B.C.
0
P j:7:"iqS Col
�9 75 51 L O 9 I
18. psum board material shall conform to ASTM 6 C C4 C 4. C 3 C 3 �--`���°::...•..,-
Gyp h C3 -�:'.
C40, C1002, C1041,CII1i, C1118, C1218, C1395, or C13`1 and shall be installed '`' -n
according to the following: (FBC R102.3.5)
a>
Drywall Framing Max. spacing Nail sizing options for
Thickness Location Orientation Member of fasteners g p
Spacing installation of drgwell into
Maximum Nails screws wood framing members
2" x min. thickness
Ceiling Perpendicular 24' 11, 12" 13ga 1 3/8" long with 19/44" head
0.098" diameter x 1 1/4" Iong
annular -ringed or 5d cooler nail
OR
/2 walla Either 1 14" 8" 16" 0.080" dia. xx 15/8' long with
Direction 15/44" head
OR
Ggpsum board nail 0.084" dia.
x 1 5/8" with 9/32" head.
Ceding Perpendicular 24' 1" l2" 13ga 1 5/8" log with 19/44' head
0.098" diameter x 1 3/8" long
annular -ringed or 6d cooler nail
Walls Either IL" 8" 16" 0.092' dia. 11/8" long with
Direction I/4" head
OR
Ggpsum board nail 0.0915" dia.
x 11/8" with 19/64" head.
Install 5GD thru buck into
block with 3/14" tap -con with --
1 1/2" penetration at 6" o.c. max.
from each corner and 20." o.c. max
thereafter at head per product approval
Use 3/16" tap -con with
1 1/2" penetration at 6" o.c. max.
from each corner and 20" o.c. max
thereafter at sill per product appro
19. ALL ceramic the surfaces installed shall conform to ASTM A108.1 thru A108.6,
A108.1, A118.1, A118.3, A136.1 and A131.1
20. Cement, fiber -cement or glass mat g psum backers in accordance with ASTM
C1288, C1325, OR C1178 and installed I.A.W. manufacturers recommendations shall
be used as backer for the Wall the in tub areas and Wall panels in shower areas.
21. Insulation including facings such as retarders or vapor permeable members installed
within floor -ceiling assemblies, roof -ceiling assemblies, Wall, crawl spaces and attics
shall have a flame spread index not to exceed 25 With an accompan4ing smoke
developed index not to exceed 450 when tested in accordance with ASTM E 84.
Insulation shall comply with F.B.C. R316.
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL 11:11651.12
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self aealing washer at 12' o.c. max spacing over ASTM D
(type 2) 30 lb felt underlagment installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6" o.e. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet \
Simpson HETA 20 or equal
hurricane anchor at each truss
with (10) 10d x 1 1/2" nails
( 24" o.c.) supporting Max.
18101bs. uplift
12
4
PRE-ENGINEERED TRUSSES
at 24"o.c. TYPICAL
(shop drawings by manufacturer)
Aluminum Drip -- �V i \R-30 blown fiberglass
Edge il Fascia in bottom chord oP trusses
I/2" drgwall with smooth finish
2" x 6" Sub -Fascia Two rows of beam block filled with concrete
and (l) #5 bar cunt. in each row. Substitute
Kagcan full o vent vmul soffit installed precast lintel filled with concrete and (1) #5
using 1/8" dia shank x 1.51 long gals. bar cont. for bottom row over openings
roofing nails with 5/e" dia. head par
product approval - we chart sheet #i 1/2" drywall over I" x rurmngg
strips of 19" o.c. with R4.1 f#-foil
insulation on typical On Block walls
5/8' thick light textured = All drywall to be installed per FBC R102.3.1
stucco on typical concrete T and shall meet all pertaining ASTM codes.
block construction m Mortar to be Type "M" onig proportioned per FBC R601.1
and Mortar fonts aht}Il comply with FBC R601.2.1.
Provide Dur-O-Rock at all wet areas (ex. showers, tubs etc...)
#5 bar vert. w/
30" overlap Fill cell with concrete and
at each filled cell (D #5 bar vert. (typical).
Max. apacing shall not exceed
Wood 48' unless otherwise noted
Base see foundation plan notes for
spacing at openings
6°x4" concrete slab with fibermesh OR
V #10/10 WWM on 6 mil Visqueen over
clean compacted termite treated fill
i
Grade ;
"i 1 1 I I I ill 14" x 14" Concrete footing
I+F with (2) #5 bars corif- and #5
TY F' i C A L S E C T I O �l transverse bars at 4$" o.c.
Scale 1/2" = 1'-0"
AREA CALCULATIONS
Living A/C = 144L sq. ft.
Front Porch = 141 sq. ft.
Rear Porch = 200 sq. ft,
Garage = 321 sq. ft.
Total Under Roof= ' 2108 sq. ft.
Total Cubic Ft = 11,548
2" VTR
1
i
I
I
21' VTR
Masterr�� JiL
Bath
IL " I
2' I
Lev. 1
4" 1 2" VTR
W.C. JIL
I
Shur.
Kit. Sink 1
I
Kitchen 2A
I
I
Lev.
3"
w c.
Bath #2 sh,.
3'
to
C.O. To septic
PLUMBING RISER
I" x 6" P.T. Buck nailed to
block with case hardened nails
Head prior to door attachment
fixed door
sliding door
Masonry Wall II n
\
11/2"
Bottom Track Typical Flooring
Sill Install 5GD thru buck into
block with 3/16" tap -con with
Sliding D o o r D e I penetration at max.
fromom each corner and 20.." o.c. max
thereafter at Jambs per product approval Jamb
At Masonry Wall NTS
Window Schedule
Mark Size Rough Open. Window Description PRESSURE ZONE
I. 4'-5%"x 5'-3%" 54ie"x 63i4" Single Hung ZONE 4
2. 6'-2%"x 5'-3 %a" 15" x 63 %;' Single Hung ZONE 4
3. 2'-2" x 3'-2 1/2" 1 2l k2"x 38 %" Single Hung ZONE 4
4. 4'-5%-x 4'-2%' 1 S4%'x 54Y8" Single Hung I ZONE 4
ALL Windows to be aluminum windows w/ tint
and mullions per elevations.
ALL windows to withstand pressures in permit Info box on sheet I
ALL windows in bathrooms to be tempered
All rough opening dimensions to be verified bg contractor
with manufacturer s specs prior to construction
Door Schedule
Mark Size Rough Opening Door Description PRESSURE ZONE
A 9'-0" X 1'-0" 108" x 84' Overhead Garage Door ZONE 4
B 3'-O" X 6'-an 41 %,"x 83%d' Fiberglass Panel - Inswing ZONE 4
C 6'-0" X 6'-8" 14" x 81 %2" ;c wSg1 Sliding Glass Door ZONE 4
D 2'-O" X 6'-8" Solid Core - Wood - 6-Panel -Bi-Fold Finished 24" x 811/2"
E 2'-6" X 6'-8" Solid Core - Wood - 6-Panel
F 5'-0" X 6'-8" Solid Core - Wood - 6-Panel - Bi-Fold
G 2'-8" x 6'-8" x I %f" Solid Core Wood, Steel, or Masonite Door
H 2'-8" X 6'-8" Solid Core - Wood - 6-Panel
2'-6" X C-8" Solid Core - Wood - 6-Panel - Bi-Fold
K 2'-8" X 6'-8" Solid Core - Wood - 6-Panel - Si -Fold
ALL Exterior doors to withstand pressures stated in permit info
box on sheet 41
GARAGE DOOR SPECIFIED IN PRODUCT APPROVAL FORM AND SHALL
WITHSTAND THE PRESSURES STATED IN PERMIT INFO BOX ON SHEET #I
All rough opening dimensions to be verified bg contractor
with manufacturers specs prior to construction
I�
i�
8'-6"
12" x 12" Concrete column
block filled with concrete and
(2) 41 bars vert. tied into
lintels above
Covered Porch
34'-O"
11
I v
8'-0" to T-I " A.F.F. OL
Vaulted Ceiling
GR AT
R OM
I
I
19'-a"
i I
N I
8'-0" to 9'-e" A.F.Q. 2" x 6" knee -wall
Vaulted Ceiling I below counter top
DINING I
14'-O"
EGRESS
N
MASTER
BEDROOM
8'-0" A.F.F. Al
Flat Ceiling
1 Vanity to
34142' high-
s1 V
'r-
0
L SET
N I >J_� N
ROOM I a ,F I Rod Shelf
p�-
--a-
Vanit to be
1
34 Y2 high I I
High wall KII T C H E N
I -
N --� 1/2"---d O
u
8'-0" A.F.F. ot
u U c Flat Ceding
to
�LL A SECOND
" ry BEDROOM
d
0. L�EGRESS
ver-hang 8'-O" A.F.F.
I Flat Ceiling N
109 5"
I pper ca nets to
extend over Ref.
- ai - eta
m
1
It,
BATS
_ 1 N -II Batts wleei"
N
- -"4 Steel Ballard
in = I ill, - - �I¢ doled on this rhea
�t 22' x 54' I
Attic Access Provide auto
1 with light I closer
a Q si L_____�
r
I
MILJI oo "ILU ,
3'-1" O O
O 12" x 12' contra a column block filled
COVERED
i ith concrete and (2) #1 bars vert. tied R C
O1 in into I tels above
s l000l
G" II'-6" 6' 2"
(V of 0 "
2'-8° 2,-8„
31111
9'-6" 3,-4" 5'-'4"
34'-O"
Install windows thru buck into
block with 3/16' tap
-con with
1 1/2" penetration at 6" o.c. max.
from each corner and 20." o.c. max
thereafter at iambs and 20" o.c. max.
Exterior face at head and sill per product approval
of wall / \ Buck to be I" x 4" PT
s
3'-5"
GO +mp
Panel
GARAGE
8'-4" A.F.F. a
Flat Ceding
O
N
r-----------------1
Block wall in
garage to be -�
I struck block I
I I
I I
I I
I
I
I � I
I I
9'-O" 3'-5"
15'-10"
REVIEW D FOR
)DE CO PLIANCE
r. LUCIE (COUNTY
NLL
Vent
" filler,
A/C 'v-
Meter
Attach buck to block wall with
Vol' dia. Elco conic screws with min.
1 1/4' penetration at 12" o.c. max
and 4" max from each corner thru
Exterior face 2' x 6" PT Buck
of wall / \
I"x4" P.T. Buck nailed to INSTALL VULKEM BLOCK SEALANT
lock with case hardened nails ON ALL JAMB, HEADER, AND
Detail at Windows prior to window attachment SILL BLOCK PRIOR TO BUCK Detail at Door
INSTALLATION
NTS
Braden t Braden ,AIA, FA Wynne Building Corp. MODEL: Date Drawn Revisions
Architects - Planners
411 S.E. Coconut Avenue The rand Carlton G RIGHT
E Drawn bg:
Tel (112) 281-8258C.C_U.
Fax (rade 287-8283 Spanish Lakes Checked b
E-mail:W B bradenalascomcast.net St. Lucie County Florida D.R.B. y
Stuart. FL S499L #AAC000032
48 Wood screws thru ,lamb into buck
at each hinge and 15" o.c. max and
prior to door attachment
NTs
Sheet
2,
OF 5
Comm
12-2-1
Drywall Framing Max. spacing Nail sizing options for
Thickness Location Orientation Member of fasteners g p
Spacing installation of drgwell into
Maximum Nails screws wood framing members
2" x min. thickness
Ceiling Perpendicular 24' 11, 12" 13ga 1 3/8" long with 19/44" head
0.098" diameter x 1 1/4" Iong
annular -ringed or 5d cooler nail
OR
/2 walla Either 1 14" 8" 16" 0.080" dia. xx 15/8' long with
Direction 15/44" head
OR
Ggpsum board nail 0.084" dia.
x 1 5/8" with 9/32" head.
Ceding Perpendicular 24' 1" l2" 13ga 1 5/8" log with 19/44' head
0.098" diameter x 1 3/8" long
annular -ringed or 6d cooler nail
Walls Either IL" 8" 16" 0.092' dia. 11/8" long with
Direction I/4" head
OR
Ggpsum board nail 0.0915" dia.
x 11/8" with 19/64" head.
Install 5GD thru buck into
block with 3/14" tap -con with --
1 1/2" penetration at 6" o.c. max.
from each corner and 20." o.c. max
thereafter at head per product approval
Use 3/16" tap -con with
1 1/2" penetration at 6" o.c. max.
from each corner and 20" o.c. max
thereafter at sill per product appro
19. ALL ceramic the surfaces installed shall conform to ASTM A108.1 thru A108.6,
A108.1, A118.1, A118.3, A136.1 and A131.1
20. Cement, fiber -cement or glass mat g psum backers in accordance with ASTM
C1288, C1325, OR C1178 and installed I.A.W. manufacturers recommendations shall
be used as backer for the Wall the in tub areas and Wall panels in shower areas.
21. Insulation including facings such as retarders or vapor permeable members installed
within floor -ceiling assemblies, roof -ceiling assemblies, Wall, crawl spaces and attics
shall have a flame spread index not to exceed 25 With an accompan4ing smoke
developed index not to exceed 450 when tested in accordance with ASTM E 84.
Insulation shall comply with F.B.C. R316.
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL 11:11651.12
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self aealing washer at 12' o.c. max spacing over ASTM D
(type 2) 30 lb felt underlagment installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6" o.e. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet \
Simpson HETA 20 or equal
hurricane anchor at each truss
with (10) 10d x 1 1/2" nails
( 24" o.c.) supporting Max.
18101bs. uplift
12
4
PRE-ENGINEERED TRUSSES
at 24"o.c. TYPICAL
(shop drawings by manufacturer)
Aluminum Drip -- �V i \R-30 blown fiberglass
Edge il Fascia in bottom chord oP trusses
I/2" drgwall with smooth finish
2" x 6" Sub -Fascia Two rows of beam block filled with concrete
and (l) #5 bar cunt. in each row. Substitute
Kagcan full o vent vmul soffit installed precast lintel filled with concrete and (1) #5
using 1/8" dia shank x 1.51 long gals. bar cont. for bottom row over openings
roofing nails with 5/e" dia. head par
product approval - we chart sheet #i 1/2" drywall over I" x rurmngg
strips of 19" o.c. with R4.1 f#-foil
insulation on typical On Block walls
5/8' thick light textured = All drywall to be installed per FBC R102.3.1
stucco on typical concrete T and shall meet all pertaining ASTM codes.
block construction m Mortar to be Type "M" onig proportioned per FBC R601.1
and Mortar fonts aht}Il comply with FBC R601.2.1.
Provide Dur-O-Rock at all wet areas (ex. showers, tubs etc...)
#5 bar vert. w/
30" overlap Fill cell with concrete and
at each filled cell (D #5 bar vert. (typical).
Max. apacing shall not exceed
Wood 48' unless otherwise noted
Base see foundation plan notes for
spacing at openings
6°x4" concrete slab with fibermesh OR
V #10/10 WWM on 6 mil Visqueen over
clean compacted termite treated fill
i
Grade ;
"i 1 1 I I I ill 14" x 14" Concrete footing
I+F with (2) #5 bars corif- and #5
TY F' i C A L S E C T I O �l transverse bars at 4$" o.c.
Scale 1/2" = 1'-0"
AREA CALCULATIONS
Living A/C = 144L sq. ft.
Front Porch = 141 sq. ft.
Rear Porch = 200 sq. ft,
Garage = 321 sq. ft.
Total Under Roof= ' 2108 sq. ft.
Total Cubic Ft = 11,548
2" VTR
1
i
I
I
21' VTR
Masterr�� JiL
Bath
IL " I
2' I
Lev. 1
4" 1 2" VTR
W.C. JIL
I
Shur.
Kit. Sink 1
I
Kitchen 2A
I
I
Lev.
3"
w c.
Bath #2 sh,.
3'
to
C.O. To septic
PLUMBING RISER
I" x 6" P.T. Buck nailed to
block with case hardened nails
Head prior to door attachment
fixed door
sliding door
Masonry Wall II n
\
11/2"
Bottom Track Typical Flooring
Sill Install 5GD thru buck into
block with 3/16" tap -con with
Sliding D o o r D e I penetration at max.
fromom each corner and 20.." o.c. max
thereafter at Jambs per product approval Jamb
At Masonry Wall NTS
Window Schedule
Mark Size Rough Open. Window Description PRESSURE ZONE
I. 4'-5%"x 5'-3%" 54ie"x 63i4" Single Hung ZONE 4
2. 6'-2%"x 5'-3 %a" 15" x 63 %;' Single Hung ZONE 4
3. 2'-2" x 3'-2 1/2" 1 2l k2"x 38 %" Single Hung ZONE 4
4. 4'-5%-x 4'-2%' 1 S4%'x 54Y8" Single Hung I ZONE 4
ALL Windows to be aluminum windows w/ tint
and mullions per elevations.
ALL windows to withstand pressures in permit Info box on sheet I
ALL windows in bathrooms to be tempered
All rough opening dimensions to be verified bg contractor
with manufacturer s specs prior to construction
Door Schedule
Mark Size Rough Opening Door Description PRESSURE ZONE
A 9'-0" X 1'-0" 108" x 84' Overhead Garage Door ZONE 4
B 3'-O" X 6'-an 41 %,"x 83%d' Fiberglass Panel - Inswing ZONE 4
C 6'-0" X 6'-8" 14" x 81 %2" ;c wSg1 Sliding Glass Door ZONE 4
D 2'-O" X 6'-8" Solid Core - Wood - 6-Panel -Bi-Fold Finished 24" x 811/2"
E 2'-6" X 6'-8" Solid Core - Wood - 6-Panel
F 5'-0" X 6'-8" Solid Core - Wood - 6-Panel - Bi-Fold
G 2'-8" x 6'-8" x I %f" Solid Core Wood, Steel, or Masonite Door
H 2'-8" X 6'-8" Solid Core - Wood - 6-Panel
2'-6" X C-8" Solid Core - Wood - 6-Panel - Bi-Fold
K 2'-8" X 6'-8" Solid Core - Wood - 6-Panel - Si -Fold
ALL Exterior doors to withstand pressures stated in permit info
box on sheet 41
GARAGE DOOR SPECIFIED IN PRODUCT APPROVAL FORM AND SHALL
WITHSTAND THE PRESSURES STATED IN PERMIT INFO BOX ON SHEET #I
All rough opening dimensions to be verified bg contractor
with manufacturers specs prior to construction
I�
i�
8'-6"
12" x 12" Concrete column
block filled with concrete and
(2) 41 bars vert. tied into
lintels above
Covered Porch
34'-O"
11
I v
8'-0" to T-I " A.F.F. OL
Vaulted Ceiling
GR AT
R OM
I
I
19'-a"
i I
N I
8'-0" to 9'-e" A.F.Q. 2" x 6" knee -wall
Vaulted Ceiling I below counter top
DINING I
14'-O"
EGRESS
N
MASTER
BEDROOM
8'-0" A.F.F. Al
Flat Ceiling
1 Vanity to
34142' high-
s1 V
'r-
0
L SET
N I >J_� N
ROOM I a ,F I Rod Shelf
p�-
--a-
Vanit to be
1
34 Y2 high I I
High wall KII T C H E N
I -
N --� 1/2"---d O
u
8'-0" A.F.F. ot
u U c Flat Ceding
to
�LL A SECOND
" ry BEDROOM
d
0. L�EGRESS
ver-hang 8'-O" A.F.F.
I Flat Ceiling N
109 5"
I pper ca nets to
extend over Ref.
- ai - eta
m
1
It,
BATS
_ 1 N -II Batts wleei"
N
- -"4 Steel Ballard
in = I ill, - - �I¢ doled on this rhea
�t 22' x 54' I
Attic Access Provide auto
1 with light I closer
a Q si L_____�
r
I
MILJI oo "ILU ,
3'-1" O O
O 12" x 12' contra a column block filled
COVERED
i ith concrete and (2) #1 bars vert. tied R C
O1 in into I tels above
s l000l
G" II'-6" 6' 2"
(V of 0 "
2'-8° 2,-8„
31111
9'-6" 3,-4" 5'-'4"
34'-O"
Install windows thru buck into
block with 3/16' tap
-con with
1 1/2" penetration at 6" o.c. max.
from each corner and 20." o.c. max
thereafter at iambs and 20" o.c. max.
Exterior face at head and sill per product approval
of wall / \ Buck to be I" x 4" PT
s
3'-5"
GO +mp
Panel
GARAGE
8'-4" A.F.F. a
Flat Ceding
O
N
r-----------------1
Block wall in
garage to be -�
I struck block I
I I
I I
I I
I
I
I � I
I I
9'-O" 3'-5"
15'-10"
REVIEW D FOR
)DE CO PLIANCE
r. LUCIE (COUNTY
NLL
Vent
" filler,
A/C 'v-
Meter
Attach buck to block wall with
Vol' dia. Elco conic screws with min.
1 1/4' penetration at 12" o.c. max
and 4" max from each corner thru
Exterior face 2' x 6" PT Buck
of wall / \
I"x4" P.T. Buck nailed to INSTALL VULKEM BLOCK SEALANT
lock with case hardened nails ON ALL JAMB, HEADER, AND
Detail at Windows prior to window attachment SILL BLOCK PRIOR TO BUCK Detail at Door
INSTALLATION
NTS
Braden t Braden ,AIA, FA Wynne Building Corp. MODEL: Date Drawn Revisions
Architects - Planners
411 S.E. Coconut Avenue The rand Carlton G RIGHT
E Drawn bg:
Tel (112) 281-8258C.C_U.
Fax (rade 287-8283 Spanish Lakes Checked b
E-mail:W B bradenalascomcast.net St. Lucie County Florida D.R.B. y
Stuart. FL S499L #AAC000032
48 Wood screws thru ,lamb into buck
at each hinge and 15" o.c. max and
prior to door attachment
NTs
Sheet
2,
OF 5
Comm
12-2-1
Install 5GD thru buck into
block with 3/14" tap -con with --
1 1/2" penetration at 6" o.c. max.
from each corner and 20." o.c. max
thereafter at head per product approval
Use 3/16" tap -con with
1 1/2" penetration at 6" o.c. max.
from each corner and 20" o.c. max
thereafter at sill per product appro
19. ALL ceramic the surfaces installed shall conform to ASTM A108.1 thru A108.6,
A108.1, A118.1, A118.3, A136.1 and A131.1
20. Cement, fiber -cement or glass mat g psum backers in accordance with ASTM
C1288, C1325, OR C1178 and installed I.A.W. manufacturers recommendations shall
be used as backer for the Wall the in tub areas and Wall panels in shower areas.
21. Insulation including facings such as retarders or vapor permeable members installed
within floor -ceiling assemblies, roof -ceiling assemblies, Wall, crawl spaces and attics
shall have a flame spread index not to exceed 25 With an accompan4ing smoke
developed index not to exceed 450 when tested in accordance with ASTM E 84.
Insulation shall comply with F.B.C. R316.
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL 11:11651.12
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self aealing washer at 12' o.c. max spacing over ASTM D
(type 2) 30 lb felt underlagment installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6" o.e. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet \
Simpson HETA 20 or equal
hurricane anchor at each truss
with (10) 10d x 1 1/2" nails
( 24" o.c.) supporting Max.
18101bs. uplift
12
4
PRE-ENGINEERED TRUSSES
at 24"o.c. TYPICAL
(shop drawings by manufacturer)
Aluminum Drip -- �V i \R-30 blown fiberglass
Edge il Fascia in bottom chord oP trusses
I/2" drgwall with smooth finish
2" x 6" Sub -Fascia Two rows of beam block filled with concrete
and (l) #5 bar cunt. in each row. Substitute
Kagcan full o vent vmul soffit installed precast lintel filled with concrete and (1) #5
using 1/8" dia shank x 1.51 long gals. bar cont. for bottom row over openings
roofing nails with 5/e" dia. head par
product approval - we chart sheet #i 1/2" drywall over I" x rurmngg
strips of 19" o.c. with R4.1 f#-foil
insulation on typical On Block walls
5/8' thick light textured = All drywall to be installed per FBC R102.3.1
stucco on typical concrete T and shall meet all pertaining ASTM codes.
block construction m Mortar to be Type "M" onig proportioned per FBC R601.1
and Mortar fonts aht}Il comply with FBC R601.2.1.
Provide Dur-O-Rock at all wet areas (ex. showers, tubs etc...)
#5 bar vert. w/
30" overlap Fill cell with concrete and
at each filled cell (D #5 bar vert. (typical).
Max. apacing shall not exceed
Wood 48' unless otherwise noted
Base see foundation plan notes for
spacing at openings
6°x4" concrete slab with fibermesh OR
V #10/10 WWM on 6 mil Visqueen over
clean compacted termite treated fill
i
Grade ;
"i 1 1 I I I ill 14" x 14" Concrete footing
I+F with (2) #5 bars corif- and #5
TY F' i C A L S E C T I O �l transverse bars at 4$" o.c.
Scale 1/2" = 1'-0"
AREA CALCULATIONS
Living A/C = 144L sq. ft.
Front Porch = 141 sq. ft.
Rear Porch = 200 sq. ft,
Garage = 321 sq. ft.
Total Under Roof= ' 2108 sq. ft.
Total Cubic Ft = 11,548
2" VTR
1
i
I
I
21' VTR
Masterr�� JiL
Bath
IL " I
2' I
Lev. 1
4" 1 2" VTR
W.C. JIL
I
Shur.
Kit. Sink 1
I
Kitchen 2A
I
I
Lev.
3"
w c.
Bath #2 sh,.
3'
to
C.O. To septic
PLUMBING RISER
I" x 6" P.T. Buck nailed to
block with case hardened nails
Head prior to door attachment
fixed door
sliding door
Masonry Wall II n
\
11/2"
Bottom Track Typical Flooring
Sill Install 5GD thru buck into
block with 3/16" tap -con with
Sliding D o o r D e I penetration at max.
fromom each corner and 20.." o.c. max
thereafter at Jambs per product approval Jamb
At Masonry Wall NTS
Window Schedule
Mark Size Rough Open. Window Description PRESSURE ZONE
I. 4'-5%"x 5'-3%" 54ie"x 63i4" Single Hung ZONE 4
2. 6'-2%"x 5'-3 %a" 15" x 63 %;' Single Hung ZONE 4
3. 2'-2" x 3'-2 1/2" 1 2l k2"x 38 %" Single Hung ZONE 4
4. 4'-5%-x 4'-2%' 1 S4%'x 54Y8" Single Hung I ZONE 4
ALL Windows to be aluminum windows w/ tint
and mullions per elevations.
ALL windows to withstand pressures in permit Info box on sheet I
ALL windows in bathrooms to be tempered
All rough opening dimensions to be verified bg contractor
with manufacturer s specs prior to construction
Door Schedule
Mark Size Rough Opening Door Description PRESSURE ZONE
A 9'-0" X 1'-0" 108" x 84' Overhead Garage Door ZONE 4
B 3'-O" X 6'-an 41 %,"x 83%d' Fiberglass Panel - Inswing ZONE 4
C 6'-0" X 6'-8" 14" x 81 %2" ;c wSg1 Sliding Glass Door ZONE 4
D 2'-O" X 6'-8" Solid Core - Wood - 6-Panel -Bi-Fold Finished 24" x 811/2"
E 2'-6" X 6'-8" Solid Core - Wood - 6-Panel
F 5'-0" X 6'-8" Solid Core - Wood - 6-Panel - Bi-Fold
G 2'-8" x 6'-8" x I %f" Solid Core Wood, Steel, or Masonite Door
H 2'-8" X 6'-8" Solid Core - Wood - 6-Panel
2'-6" X C-8" Solid Core - Wood - 6-Panel - Bi-Fold
K 2'-8" X 6'-8" Solid Core - Wood - 6-Panel - Si -Fold
ALL Exterior doors to withstand pressures stated in permit info
box on sheet 41
GARAGE DOOR SPECIFIED IN PRODUCT APPROVAL FORM AND SHALL
WITHSTAND THE PRESSURES STATED IN PERMIT INFO BOX ON SHEET #I
All rough opening dimensions to be verified bg contractor
with manufacturers specs prior to construction
I�
i�
8'-6"
12" x 12" Concrete column
block filled with concrete and
(2) 41 bars vert. tied into
lintels above
Covered Porch
34'-O"
11
I v
8'-0" to T-I " A.F.F. OL
Vaulted Ceiling
GR AT
R OM
I
I
19'-a"
i I
N I
8'-0" to 9'-e" A.F.Q. 2" x 6" knee -wall
Vaulted Ceiling I below counter top
DINING I
14'-O"
EGRESS
N
MASTER
BEDROOM
8'-0" A.F.F. Al
Flat Ceiling
1 Vanity to
34142' high-
s1 V
'r-
0
L SET
N I >J_� N
ROOM I a ,F I Rod Shelf
p�-
--a-
Vanit to be
1
34 Y2 high I I
High wall KII T C H E N
I -
N --� 1/2"---d O
u
8'-0" A.F.F. ot
u U c Flat Ceding
to
�LL A SECOND
" ry BEDROOM
d
0. L�EGRESS
ver-hang 8'-O" A.F.F.
I Flat Ceiling N
109 5"
I pper ca nets to
extend over Ref.
- ai - eta
m
1
It,
BATS
_ 1 N -II Batts wleei"
N
- -"4 Steel Ballard
in = I ill, - - �I¢ doled on this rhea
�t 22' x 54' I
Attic Access Provide auto
1 with light I closer
a Q si L_____�
r
I
MILJI oo "ILU ,
3'-1" O O
O 12" x 12' contra a column block filled
COVERED
i ith concrete and (2) #1 bars vert. tied R C
O1 in into I tels above
s l000l
G" II'-6" 6' 2"
(V of 0 "
2'-8° 2,-8„
31111
9'-6" 3,-4" 5'-'4"
34'-O"
Install windows thru buck into
block with 3/16' tap
-con with
1 1/2" penetration at 6" o.c. max.
from each corner and 20." o.c. max
thereafter at iambs and 20" o.c. max.
Exterior face at head and sill per product approval
of wall / \ Buck to be I" x 4" PT
s
3'-5"
GO +mp
Panel
GARAGE
8'-4" A.F.F. a
Flat Ceding
O
N
r-----------------1
Block wall in
garage to be -�
I struck block I
I I
I I
I I
I
I
I � I
I I
9'-O" 3'-5"
15'-10"
REVIEW D FOR
)DE CO PLIANCE
r. LUCIE (COUNTY
NLL
Vent
" filler,
A/C 'v-
Meter
Attach buck to block wall with
Vol' dia. Elco conic screws with min.
1 1/4' penetration at 12" o.c. max
and 4" max from each corner thru
Exterior face 2' x 6" PT Buck
of wall / \
I"x4" P.T. Buck nailed to INSTALL VULKEM BLOCK SEALANT
lock with case hardened nails ON ALL JAMB, HEADER, AND
Detail at Windows prior to window attachment SILL BLOCK PRIOR TO BUCK Detail at Door
INSTALLATION
NTS
Braden t Braden ,AIA, FA Wynne Building Corp. MODEL: Date Drawn Revisions
Architects - Planners
411 S.E. Coconut Avenue The rand Carlton G RIGHT
E Drawn bg:
Tel (112) 281-8258C.C_U.
Fax (rade 287-8283 Spanish Lakes Checked b
E-mail:W B bradenalascomcast.net St. Lucie County Florida D.R.B. y
Stuart. FL S499L #AAC000032
48 Wood screws thru ,lamb into buck
at each hinge and 15" o.c. max and
prior to door attachment
NTs
Sheet
2,
OF 5
Comm
12-2-1
AREA CALCULATIONS
Living A/C = 144L sq. ft.
Front Porch = 141 sq. ft.
Rear Porch = 200 sq. ft,
Garage = 321 sq. ft.
Total Under Roof= ' 2108 sq. ft.
Total Cubic Ft = 11,548
2" VTR
1
i
I
I
21' VTR
Masterr�� JiL
Bath
IL " I
2' I
Lev. 1
4" 1 2" VTR
W.C. JIL
I
Shur.
Kit. Sink 1
I
Kitchen 2A
I
I
Lev.
3"
w c.
Bath #2 sh,.
3'
to
C.O. To septic
PLUMBING RISER
I" x 6" P.T. Buck nailed to
block with case hardened nails
Head prior to door attachment
fixed door
sliding door
Masonry Wall II n
\
11/2"
Bottom Track Typical Flooring
Sill Install 5GD thru buck into
block with 3/16" tap -con with
Sliding D o o r D e I penetration at max.
fromom each corner and 20.." o.c. max
thereafter at Jambs per product approval Jamb
At Masonry Wall NTS
Window Schedule
Mark Size Rough Open. Window Description PRESSURE ZONE
I. 4'-5%"x 5'-3%" 54ie"x 63i4" Single Hung ZONE 4
2. 6'-2%"x 5'-3 %a" 15" x 63 %;' Single Hung ZONE 4
3. 2'-2" x 3'-2 1/2" 1 2l k2"x 38 %" Single Hung ZONE 4
4. 4'-5%-x 4'-2%' 1 S4%'x 54Y8" Single Hung I ZONE 4
ALL Windows to be aluminum windows w/ tint
and mullions per elevations.
ALL windows to withstand pressures in permit Info box on sheet I
ALL windows in bathrooms to be tempered
All rough opening dimensions to be verified bg contractor
with manufacturer s specs prior to construction
Door Schedule
Mark Size Rough Opening Door Description PRESSURE ZONE
A 9'-0" X 1'-0" 108" x 84' Overhead Garage Door ZONE 4
B 3'-O" X 6'-an 41 %,"x 83%d' Fiberglass Panel - Inswing ZONE 4
C 6'-0" X 6'-8" 14" x 81 %2" ;c wSg1 Sliding Glass Door ZONE 4
D 2'-O" X 6'-8" Solid Core - Wood - 6-Panel -Bi-Fold Finished 24" x 811/2"
E 2'-6" X 6'-8" Solid Core - Wood - 6-Panel
F 5'-0" X 6'-8" Solid Core - Wood - 6-Panel - Bi-Fold
G 2'-8" x 6'-8" x I %f" Solid Core Wood, Steel, or Masonite Door
H 2'-8" X 6'-8" Solid Core - Wood - 6-Panel
2'-6" X C-8" Solid Core - Wood - 6-Panel - Bi-Fold
K 2'-8" X 6'-8" Solid Core - Wood - 6-Panel - Si -Fold
ALL Exterior doors to withstand pressures stated in permit info
box on sheet 41
GARAGE DOOR SPECIFIED IN PRODUCT APPROVAL FORM AND SHALL
WITHSTAND THE PRESSURES STATED IN PERMIT INFO BOX ON SHEET #I
All rough opening dimensions to be verified bg contractor
with manufacturers specs prior to construction
I�
i�
8'-6"
12" x 12" Concrete column
block filled with concrete and
(2) 41 bars vert. tied into
lintels above
Covered Porch
34'-O"
11
I v
8'-0" to T-I " A.F.F. OL
Vaulted Ceiling
GR AT
R OM
I
I
19'-a"
i I
N I
8'-0" to 9'-e" A.F.Q. 2" x 6" knee -wall
Vaulted Ceiling I below counter top
DINING I
14'-O"
EGRESS
N
MASTER
BEDROOM
8'-0" A.F.F. Al
Flat Ceiling
1 Vanity to
34142' high-
s1 V
'r-
0
L SET
N I >J_� N
ROOM I a ,F I Rod Shelf
p�-
--a-
Vanit to be
1
34 Y2 high I I
High wall KII T C H E N
I -
N --� 1/2"---d O
u
8'-0" A.F.F. ot
u U c Flat Ceding
to
�LL A SECOND
" ry BEDROOM
d
0. L�EGRESS
ver-hang 8'-O" A.F.F.
I Flat Ceiling N
109 5"
I pper ca nets to
extend over Ref.
- ai - eta
m
1
It,
BATS
_ 1 N -II Batts wleei"
N
- -"4 Steel Ballard
in = I ill, - - �I¢ doled on this rhea
�t 22' x 54' I
Attic Access Provide auto
1 with light I closer
a Q si L_____�
r
I
MILJI oo "ILU ,
3'-1" O O
O 12" x 12' contra a column block filled
COVERED
i ith concrete and (2) #1 bars vert. tied R C
O1 in into I tels above
s l000l
G" II'-6" 6' 2"
(V of 0 "
2'-8° 2,-8„
31111
9'-6" 3,-4" 5'-'4"
34'-O"
Install windows thru buck into
block with 3/16' tap
-con with
1 1/2" penetration at 6" o.c. max.
from each corner and 20." o.c. max
thereafter at iambs and 20" o.c. max.
Exterior face at head and sill per product approval
of wall / \ Buck to be I" x 4" PT
s
3'-5"
GO +mp
Panel
GARAGE
8'-4" A.F.F. a
Flat Ceding
O
N
r-----------------1
Block wall in
garage to be -�
I struck block I
I I
I I
I I
I
I
I � I
I I
9'-O" 3'-5"
15'-10"
REVIEW D FOR
)DE CO PLIANCE
r. LUCIE (COUNTY
NLL
Vent
" filler,
A/C 'v-
Meter
Attach buck to block wall with
Vol' dia. Elco conic screws with min.
1 1/4' penetration at 12" o.c. max
and 4" max from each corner thru
Exterior face 2' x 6" PT Buck
of wall / \
I"x4" P.T. Buck nailed to INSTALL VULKEM BLOCK SEALANT
lock with case hardened nails ON ALL JAMB, HEADER, AND
Detail at Windows prior to window attachment SILL BLOCK PRIOR TO BUCK Detail at Door
INSTALLATION
NTS
Braden t Braden ,AIA, FA Wynne Building Corp. MODEL: Date Drawn Revisions
Architects - Planners
411 S.E. Coconut Avenue The rand Carlton G RIGHT
E Drawn bg:
Tel (112) 281-8258C.C_U.
Fax (rade 287-8283 Spanish Lakes Checked b
E-mail:W B bradenalascomcast.net St. Lucie County Florida D.R.B. y
Stuart. FL S499L #AAC000032
48 Wood screws thru ,lamb into buck
at each hinge and 15" o.c. max and
prior to door attachment
NTs
Sheet
2,
OF 5
Comm
12-2-1
I" x 6" P.T. Buck nailed to
block with case hardened nails
Head prior to door attachment
fixed door
sliding door
Masonry Wall II n
\
11/2"
Bottom Track Typical Flooring
Sill Install 5GD thru buck into
block with 3/16" tap -con with
Sliding D o o r D e I penetration at max.
fromom each corner and 20.." o.c. max
thereafter at Jambs per product approval Jamb
At Masonry Wall NTS
Window Schedule
Mark Size Rough Open. Window Description PRESSURE ZONE
I. 4'-5%"x 5'-3%" 54ie"x 63i4" Single Hung ZONE 4
2. 6'-2%"x 5'-3 %a" 15" x 63 %;' Single Hung ZONE 4
3. 2'-2" x 3'-2 1/2" 1 2l k2"x 38 %" Single Hung ZONE 4
4. 4'-5%-x 4'-2%' 1 S4%'x 54Y8" Single Hung I ZONE 4
ALL Windows to be aluminum windows w/ tint
and mullions per elevations.
ALL windows to withstand pressures in permit Info box on sheet I
ALL windows in bathrooms to be tempered
All rough opening dimensions to be verified bg contractor
with manufacturer s specs prior to construction
Door Schedule
Mark Size Rough Opening Door Description PRESSURE ZONE
A 9'-0" X 1'-0" 108" x 84' Overhead Garage Door ZONE 4
B 3'-O" X 6'-an 41 %,"x 83%d' Fiberglass Panel - Inswing ZONE 4
C 6'-0" X 6'-8" 14" x 81 %2" ;c wSg1 Sliding Glass Door ZONE 4
D 2'-O" X 6'-8" Solid Core - Wood - 6-Panel -Bi-Fold Finished 24" x 811/2"
E 2'-6" X 6'-8" Solid Core - Wood - 6-Panel
F 5'-0" X 6'-8" Solid Core - Wood - 6-Panel - Bi-Fold
G 2'-8" x 6'-8" x I %f" Solid Core Wood, Steel, or Masonite Door
H 2'-8" X 6'-8" Solid Core - Wood - 6-Panel
2'-6" X C-8" Solid Core - Wood - 6-Panel - Bi-Fold
K 2'-8" X 6'-8" Solid Core - Wood - 6-Panel - Si -Fold
ALL Exterior doors to withstand pressures stated in permit info
box on sheet 41
GARAGE DOOR SPECIFIED IN PRODUCT APPROVAL FORM AND SHALL
WITHSTAND THE PRESSURES STATED IN PERMIT INFO BOX ON SHEET #I
All rough opening dimensions to be verified bg contractor
with manufacturers specs prior to construction
I�
i�
8'-6"
12" x 12" Concrete column
block filled with concrete and
(2) 41 bars vert. tied into
lintels above
Covered Porch
34'-O"
11
I v
8'-0" to T-I " A.F.F. OL
Vaulted Ceiling
GR AT
R OM
I
I
19'-a"
i I
N I
8'-0" to 9'-e" A.F.Q. 2" x 6" knee -wall
Vaulted Ceiling I below counter top
DINING I
14'-O"
EGRESS
N
MASTER
BEDROOM
8'-0" A.F.F. Al
Flat Ceiling
1 Vanity to
34142' high-
s1 V
'r-
0
L SET
N I >J_� N
ROOM I a ,F I Rod Shelf
p�-
--a-
Vanit to be
1
34 Y2 high I I
High wall KII T C H E N
I -
N --� 1/2"---d O
u
8'-0" A.F.F. ot
u U c Flat Ceding
to
�LL A SECOND
" ry BEDROOM
d
0. L�EGRESS
ver-hang 8'-O" A.F.F.
I Flat Ceiling N
109 5"
I pper ca nets to
extend over Ref.
- ai - eta
m
1
It,
BATS
_ 1 N -II Batts wleei"
N
- -"4 Steel Ballard
in = I ill, - - �I¢ doled on this rhea
�t 22' x 54' I
Attic Access Provide auto
1 with light I closer
a Q si L_____�
r
I
MILJI oo "ILU ,
3'-1" O O
O 12" x 12' contra a column block filled
COVERED
i ith concrete and (2) #1 bars vert. tied R C
O1 in into I tels above
s l000l
G" II'-6" 6' 2"
(V of 0 "
2'-8° 2,-8„
31111
9'-6" 3,-4" 5'-'4"
34'-O"
Install windows thru buck into
block with 3/16' tap
-con with
1 1/2" penetration at 6" o.c. max.
from each corner and 20." o.c. max
thereafter at iambs and 20" o.c. max.
Exterior face at head and sill per product approval
of wall / \ Buck to be I" x 4" PT
s
3'-5"
GO +mp
Panel
GARAGE
8'-4" A.F.F. a
Flat Ceding
O
N
r-----------------1
Block wall in
garage to be -�
I struck block I
I I
I I
I I
I
I
I � I
I I
9'-O" 3'-5"
15'-10"
REVIEW D FOR
)DE CO PLIANCE
r. LUCIE (COUNTY
NLL
Vent
" filler,
A/C 'v-
Meter
Attach buck to block wall with
Vol' dia. Elco conic screws with min.
1 1/4' penetration at 12" o.c. max
and 4" max from each corner thru
Exterior face 2' x 6" PT Buck
of wall / \
I"x4" P.T. Buck nailed to INSTALL VULKEM BLOCK SEALANT
lock with case hardened nails ON ALL JAMB, HEADER, AND
Detail at Windows prior to window attachment SILL BLOCK PRIOR TO BUCK Detail at Door
INSTALLATION
NTS
Braden t Braden ,AIA, FA Wynne Building Corp. MODEL: Date Drawn Revisions
Architects - Planners
411 S.E. Coconut Avenue The rand Carlton G RIGHT
E Drawn bg:
Tel (112) 281-8258C.C_U.
Fax (rade 287-8283 Spanish Lakes Checked b
E-mail:W B bradenalascomcast.net St. Lucie County Florida D.R.B. y
Stuart. FL S499L #AAC000032
48 Wood screws thru ,lamb into buck
at each hinge and 15" o.c. max and
prior to door attachment
NTs
Sheet
2,
OF 5
Comm
12-2-1
Door Schedule
Mark Size Rough Opening Door Description PRESSURE ZONE
A 9'-0" X 1'-0" 108" x 84' Overhead Garage Door ZONE 4
B 3'-O" X 6'-an 41 %,"x 83%d' Fiberglass Panel - Inswing ZONE 4
C 6'-0" X 6'-8" 14" x 81 %2" ;c wSg1 Sliding Glass Door ZONE 4
D 2'-O" X 6'-8" Solid Core - Wood - 6-Panel -Bi-Fold Finished 24" x 811/2"
E 2'-6" X 6'-8" Solid Core - Wood - 6-Panel
F 5'-0" X 6'-8" Solid Core - Wood - 6-Panel - Bi-Fold
G 2'-8" x 6'-8" x I %f" Solid Core Wood, Steel, or Masonite Door
H 2'-8" X 6'-8" Solid Core - Wood - 6-Panel
2'-6" X C-8" Solid Core - Wood - 6-Panel - Bi-Fold
K 2'-8" X 6'-8" Solid Core - Wood - 6-Panel - Si -Fold
ALL Exterior doors to withstand pressures stated in permit info
box on sheet 41
GARAGE DOOR SPECIFIED IN PRODUCT APPROVAL FORM AND SHALL
WITHSTAND THE PRESSURES STATED IN PERMIT INFO BOX ON SHEET #I
All rough opening dimensions to be verified bg contractor
with manufacturers specs prior to construction
I�
i�
8'-6"
12" x 12" Concrete column
block filled with concrete and
(2) 41 bars vert. tied into
lintels above
Covered Porch
34'-O"
11
I v
8'-0" to T-I " A.F.F. OL
Vaulted Ceiling
GR AT
R OM
I
I
19'-a"
i I
N I
8'-0" to 9'-e" A.F.Q. 2" x 6" knee -wall
Vaulted Ceiling I below counter top
DINING I
14'-O"
EGRESS
N
MASTER
BEDROOM
8'-0" A.F.F. Al
Flat Ceiling
1 Vanity to
34142' high-
s1 V
'r-
0
L SET
N I >J_� N
ROOM I a ,F I Rod Shelf
p�-
--a-
Vanit to be
1
34 Y2 high I I
High wall KII T C H E N
I -
N --� 1/2"---d O
u
8'-0" A.F.F. ot
u U c Flat Ceding
to
�LL A SECOND
" ry BEDROOM
d
0. L�EGRESS
ver-hang 8'-O" A.F.F.
I Flat Ceiling N
109 5"
I pper ca nets to
extend over Ref.
- ai - eta
m
1
It,
BATS
_ 1 N -II Batts wleei"
N
- -"4 Steel Ballard
in = I ill, - - �I¢ doled on this rhea
�t 22' x 54' I
Attic Access Provide auto
1 with light I closer
a Q si L_____�
r
I
MILJI oo "ILU ,
3'-1" O O
O 12" x 12' contra a column block filled
COVERED
i ith concrete and (2) #1 bars vert. tied R C
O1 in into I tels above
s l000l
G" II'-6" 6' 2"
(V of 0 "
2'-8° 2,-8„
31111
9'-6" 3,-4" 5'-'4"
34'-O"
Install windows thru buck into
block with 3/16' tap
-con with
1 1/2" penetration at 6" o.c. max.
from each corner and 20." o.c. max
thereafter at iambs and 20" o.c. max.
Exterior face at head and sill per product approval
of wall / \ Buck to be I" x 4" PT
s
3'-5"
GO +mp
Panel
GARAGE
8'-4" A.F.F. a
Flat Ceding
O
N
r-----------------1
Block wall in
garage to be -�
I struck block I
I I
I I
I I
I
I
I � I
I I
9'-O" 3'-5"
15'-10"
REVIEW D FOR
)DE CO PLIANCE
r. LUCIE (COUNTY
NLL
Vent
" filler,
A/C 'v-
Meter
Attach buck to block wall with
Vol' dia. Elco conic screws with min.
1 1/4' penetration at 12" o.c. max
and 4" max from each corner thru
Exterior face 2' x 6" PT Buck
of wall / \
I"x4" P.T. Buck nailed to INSTALL VULKEM BLOCK SEALANT
lock with case hardened nails ON ALL JAMB, HEADER, AND
Detail at Windows prior to window attachment SILL BLOCK PRIOR TO BUCK Detail at Door
INSTALLATION
NTS
Braden t Braden ,AIA, FA Wynne Building Corp. MODEL: Date Drawn Revisions
Architects - Planners
411 S.E. Coconut Avenue The rand Carlton G RIGHT
E Drawn bg:
Tel (112) 281-8258C.C_U.
Fax (rade 287-8283 Spanish Lakes Checked b
E-mail:W B bradenalascomcast.net St. Lucie County Florida D.R.B. y
Stuart. FL S499L #AAC000032
48 Wood screws thru ,lamb into buck
at each hinge and 15" o.c. max and
prior to door attachment
NTs
Sheet
2,
OF 5
Comm
12-2-1
I�
i�
8'-6"
12" x 12" Concrete column
block filled with concrete and
(2) 41 bars vert. tied into
lintels above
Covered Porch
34'-O"
11
I v
8'-0" to T-I " A.F.F. OL
Vaulted Ceiling
GR AT
R OM
I
I
19'-a"
i I
N I
8'-0" to 9'-e" A.F.Q. 2" x 6" knee -wall
Vaulted Ceiling I below counter top
DINING I
14'-O"
EGRESS
N
MASTER
BEDROOM
8'-0" A.F.F. Al
Flat Ceiling
1 Vanity to
34142' high-
s1 V
'r-
0
L SET
N I >J_� N
ROOM I a ,F I Rod Shelf
p�-
--a-
Vanit to be
1
34 Y2 high I I
High wall KII T C H E N
I -
N --� 1/2"---d O
u
8'-0" A.F.F. ot
u U c Flat Ceding
to
�LL A SECOND
" ry BEDROOM
d
0. L�EGRESS
ver-hang 8'-O" A.F.F.
I Flat Ceiling N
109 5"
I pper ca nets to
extend over Ref.
- ai - eta
m
1
It,
BATS
_ 1 N -II Batts wleei"
N
- -"4 Steel Ballard
in = I ill, - - �I¢ doled on this rhea
�t 22' x 54' I
Attic Access Provide auto
1 with light I closer
a Q si L_____�
r
I
MILJI oo "ILU ,
3'-1" O O
O 12" x 12' contra a column block filled
COVERED
i ith concrete and (2) #1 bars vert. tied R C
O1 in into I tels above
s l000l
G" II'-6" 6' 2"
(V of 0 "
2'-8° 2,-8„
31111
9'-6" 3,-4" 5'-'4"
34'-O"
Install windows thru buck into
block with 3/16' tap
-con with
1 1/2" penetration at 6" o.c. max.
from each corner and 20." o.c. max
thereafter at iambs and 20" o.c. max.
Exterior face at head and sill per product approval
of wall / \ Buck to be I" x 4" PT
s
3'-5"
GO +mp
Panel
GARAGE
8'-4" A.F.F. a
Flat Ceding
O
N
r-----------------1
Block wall in
garage to be -�
I struck block I
I I
I I
I I
I
I
I � I
I I
9'-O" 3'-5"
15'-10"
REVIEW D FOR
)DE CO PLIANCE
r. LUCIE (COUNTY
NLL
Vent
" filler,
A/C 'v-
Meter
Attach buck to block wall with
Vol' dia. Elco conic screws with min.
1 1/4' penetration at 12" o.c. max
and 4" max from each corner thru
Exterior face 2' x 6" PT Buck
of wall / \
I"x4" P.T. Buck nailed to INSTALL VULKEM BLOCK SEALANT
lock with case hardened nails ON ALL JAMB, HEADER, AND
Detail at Windows prior to window attachment SILL BLOCK PRIOR TO BUCK Detail at Door
INSTALLATION
NTS
Braden t Braden ,AIA, FA Wynne Building Corp. MODEL: Date Drawn Revisions
Architects - Planners
411 S.E. Coconut Avenue The rand Carlton G RIGHT
E Drawn bg:
Tel (112) 281-8258C.C_U.
Fax (rade 287-8283 Spanish Lakes Checked b
E-mail:W B bradenalascomcast.net St. Lucie County Florida D.R.B. y
Stuart. FL S499L #AAC000032
48 Wood screws thru ,lamb into buck
at each hinge and 15" o.c. max and
prior to door attachment
NTs
Sheet
2,
OF 5
Comm
12-2-1
d
0. L�EGRESS
ver-hang 8'-O" A.F.F.
I Flat Ceiling N
109 5"
I pper ca nets to
extend over Ref.
- ai - eta
m
1
It,
BATS
_ 1 N -II Batts wleei"
N
- -"4 Steel Ballard
in = I ill, - - �I¢ doled on this rhea
�t 22' x 54' I
Attic Access Provide auto
1 with light I closer
a Q si L_____�
r
I
MILJI oo "ILU ,
3'-1" O O
O 12" x 12' contra a column block filled
COVERED
i ith concrete and (2) #1 bars vert. tied R C
O1 in into I tels above
s l000l
G" II'-6" 6' 2"
(V of 0 "
2'-8° 2,-8„
31111
9'-6" 3,-4" 5'-'4"
34'-O"
Install windows thru buck into
block with 3/16' tap
-con with
1 1/2" penetration at 6" o.c. max.
from each corner and 20." o.c. max
thereafter at iambs and 20" o.c. max.
Exterior face at head and sill per product approval
of wall / \ Buck to be I" x 4" PT
s
3'-5"
GO +mp
Panel
GARAGE
8'-4" A.F.F. a
Flat Ceding
O
N
r-----------------1
Block wall in
garage to be -�
I struck block I
I I
I I
I I
I
I
I � I
I I
9'-O" 3'-5"
15'-10"
REVIEW D FOR
)DE CO PLIANCE
r. LUCIE (COUNTY
NLL
Vent
" filler,
A/C 'v-
Meter
Attach buck to block wall with
Vol' dia. Elco conic screws with min.
1 1/4' penetration at 12" o.c. max
and 4" max from each corner thru
Exterior face 2' x 6" PT Buck
of wall / \
I"x4" P.T. Buck nailed to INSTALL VULKEM BLOCK SEALANT
lock with case hardened nails ON ALL JAMB, HEADER, AND
Detail at Windows prior to window attachment SILL BLOCK PRIOR TO BUCK Detail at Door
INSTALLATION
NTS
Braden t Braden ,AIA, FA Wynne Building Corp. MODEL: Date Drawn Revisions
Architects - Planners
411 S.E. Coconut Avenue The rand Carlton G RIGHT
E Drawn bg:
Tel (112) 281-8258C.C_U.
Fax (rade 287-8283 Spanish Lakes Checked b
E-mail:W B bradenalascomcast.net St. Lucie County Florida D.R.B. y
Stuart. FL S499L #AAC000032
48 Wood screws thru ,lamb into buck
at each hinge and 15" o.c. max and
prior to door attachment
NTs
Sheet
2,
OF 5
Comm
12-2-1
r
I
MILJI oo "ILU ,
3'-1" O O
O 12" x 12' contra a column block filled
COVERED
i ith concrete and (2) #1 bars vert. tied R C
O1 in into I tels above
s l000l
G" II'-6" 6' 2"
(V of 0 "
2'-8° 2,-8„
31111
9'-6" 3,-4" 5'-'4"
34'-O"
Install windows thru buck into
block with 3/16' tap
-con with
1 1/2" penetration at 6" o.c. max.
from each corner and 20." o.c. max
thereafter at iambs and 20" o.c. max.
Exterior face at head and sill per product approval
of wall / \ Buck to be I" x 4" PT
s
3'-5"
GO +mp
Panel
GARAGE
8'-4" A.F.F. a
Flat Ceding
O
N
r-----------------1
Block wall in
garage to be -�
I struck block I
I I
I I
I I
I
I
I � I
I I
9'-O" 3'-5"
15'-10"
REVIEW D FOR
)DE CO PLIANCE
r. LUCIE (COUNTY
NLL
Vent
" filler,
A/C 'v-
Meter
Attach buck to block wall with
Vol' dia. Elco conic screws with min.
1 1/4' penetration at 12" o.c. max
and 4" max from each corner thru
Exterior face 2' x 6" PT Buck
of wall / \
I"x4" P.T. Buck nailed to INSTALL VULKEM BLOCK SEALANT
lock with case hardened nails ON ALL JAMB, HEADER, AND
Detail at Windows prior to window attachment SILL BLOCK PRIOR TO BUCK Detail at Door
INSTALLATION
NTS
Braden t Braden ,AIA, FA Wynne Building Corp. MODEL: Date Drawn Revisions
Architects - Planners
411 S.E. Coconut Avenue The rand Carlton G RIGHT
E Drawn bg:
Tel (112) 281-8258C.C_U.
Fax (rade 287-8283 Spanish Lakes Checked b
E-mail:W B bradenalascomcast.net St. Lucie County Florida D.R.B. y
Stuart. FL S499L #AAC000032
48 Wood screws thru ,lamb into buck
at each hinge and 15" o.c. max and
prior to door attachment
NTs
Sheet
2,
OF 5
Comm
12-2-1
Install windows thru buck into
block with 3/16' tap
-con with
1 1/2" penetration at 6" o.c. max.
from each corner and 20." o.c. max
thereafter at iambs and 20" o.c. max.
Exterior face at head and sill per product approval
of wall / \ Buck to be I" x 4" PT
s
3'-5"
GO +mp
Panel
GARAGE
8'-4" A.F.F. a
Flat Ceding
O
N
r-----------------1
Block wall in
garage to be -�
I struck block I
I I
I I
I I
I
I
I � I
I I
9'-O" 3'-5"
15'-10"
REVIEW D FOR
)DE CO PLIANCE
r. LUCIE (COUNTY
NLL
Vent
" filler,
A/C 'v-
Meter
Attach buck to block wall with
Vol' dia. Elco conic screws with min.
1 1/4' penetration at 12" o.c. max
and 4" max from each corner thru
Exterior face 2' x 6" PT Buck
of wall / \
I"x4" P.T. Buck nailed to INSTALL VULKEM BLOCK SEALANT
lock with case hardened nails ON ALL JAMB, HEADER, AND
Detail at Windows prior to window attachment SILL BLOCK PRIOR TO BUCK Detail at Door
INSTALLATION
NTS
Braden t Braden ,AIA, FA Wynne Building Corp. MODEL: Date Drawn Revisions
Architects - Planners
411 S.E. Coconut Avenue The rand Carlton G RIGHT
E Drawn bg:
Tel (112) 281-8258C.C_U.
Fax (rade 287-8283 Spanish Lakes Checked b
E-mail:W B bradenalascomcast.net St. Lucie County Florida D.R.B. y
Stuart. FL S499L #AAC000032
48 Wood screws thru ,lamb into buck
at each hinge and 15" o.c. max and
prior to door attachment
NTs
Sheet
2,
OF 5
Comm
12-2-1
34'-O"
J 1 1\l.411. I l.4rN11 t"tl— IXk./ I TJ:
I. ALL FOOTING ARE DESIGNED FOR A MINIMUM OF 2,500 PSF SOIL
BEARING CAPACITY. IF ANY SUB -SOIL, MUCK OR NON -UNIFORM
CONDITIONS EXIST, REPORT TO ARCHITECT AND OBTAIN
PROPER ENGINEERING DATA FOR DESIGN.
2. ALL SLABS AND FOOTINGS TO BE A MINIMUM 2,500 PSI AT 28 DAYS
ALL COLUMNS, FILLED CELLS AND BEAMS SHALL BE MIN. 3000 PSI
BE 3000 PSI OR 4,000 PSI GROUT MIX AT 28 DAYS
3. POISON SOIL AND COVER W/ 6 MIL. VISQUEEN WITHIN 24 HOURS. NO
SOIL POISONING TO BE ACCOMPLISHED OUTSIDE OF FOUNDATION.
4 GROUND FLOOR SLAB TO BE A MINIMUM 4" THICK W/ 6X6 I0/10
WELDED WIRE MESH REINFORCING ON 6 MIL. POLYETHYLENE VAPOR
BARRIER ON TERMITE TREATED, CLEAN MACHINE COMPACTED FILL
(MINIMUM 95% DENSITY). LAP POLYETHYLENE 12" MINIMUM. FIBERMESH
MIX MAY BE SUBSTITUTED FOR WELDED WIRE MESH.
5. LOT TO BE CLEARED OF ALL SMALL PLANT GROWTH AND DEBRIS
BEFORE FILL IS BROUGHT IN. FILL MATERIAL SHALL CONSIST OF
CLEAN GRANULAR SAND CONTAINING LESS THAN 10% MATERIAL
PASSING THE US STANDARD NO. 200 MESH SIEVE. PLACE
STRUCTURAL FILL IN LOOSE LAYERS OF 12" IN THICKNESS AND
COMPACT EACH LIFT TO AT LEAST 95% OF ITS MODIFIED DRY
PROCTOR VALUE.
6• GENERAL CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND
DIMENSIONS. BRING ANY DISCREPANCIES OR OMISSIONS TO THE
ATTENTION OF THE ARCHITECT.
GARAGE FLOORS TO BE SMOOTH TROWEL FINISH (SLOPPED PER
FOUNDATION PLAN). PROVIDE 1-1/2" RECESS FOR OVERHEAD DOOR
FOUN.DATiON FLAN
8. SLOPE ALL PORCH SLABS, COVERED WALK, ETC. AWAY
FROM HOUSE TO DRAINS (IF PROVIDED) PER PLANS
9. DESIGN LOADS ARE AS FOLLOWS:
ROOF (DL+LL) = 41 PSF
WIND VELOCITY = PER PERMIT INFO BOX ON SHEET #I
EXPOSURE ="C"
10. ALL REINFORCING STEEL SHALL BE GRADE 40, MEETING ASTM A-16, t
A-35 SPECIFICATIONS. ALL ANCHOR TO BE A - 301 STEEL.
II. ALL DOWELS, SLEEVES, CONDUITS, INSERTS, BLOCKOUTS, ANCHOR
BOLTS AND FRAMES SHALL BE IN PLACE PRIOR TO POURING CONCRETE.
FOR OPENINGS AND SPECIAL FEATURES OMITTED ON THESE PLANS,
SEE ARCHITECTURAL OR MECHANICAL PLANS WHERE APPLICABLE.
12. MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS:
FOOTING: 3"
BEAMS: 1-1/2"
13. LAP ALL REINFORCING STEEL A MINIMUM of 48 BAR DIAMETERS.
14. USE STRUCTURAL GRADE WOOD WiTH A MINIMUM Fb OF 1600 PSI
15. ALL STANDARD LUMBER SHALL BE SYP WITH A MINIMUM Fb OF 1000
PSI OF NO.2 SOUTHERN FINE, UNLESS NOTED OTHERWISE.
14. ALL LUMBER IN CONTACT WITH ANY CONCRETE OR MASONRY SHALL BE
PRESSURE TREATED. FASTENERS TO HAVE MIN. G185 RATING.
I. Ang changes to plans must be submitted to the architect
for approval before proceeding with construction.
2. Contractor shall be responsible for verification of all
notation and dimensions before starting construction.
3. Soil conditions assumed to be 2500 psf, Should any other conditions be
encountered, the architect shall be notified in writing for revision
-f. Verify all recess thickness at showers, tile, etc....
S. Contractor to provide filled cell with concrete and 1 45 bar vert. at 48"
o.c. max. Provide (1) filled cell on each side of openings upto 5'-I1" wide.
Provide (2) filled cells on each side of openings from 6'-0" to 9'-11"
and Provide (3) filled cells on each side of openings from 10'-O" and up
Contractor to see plans for any other condition used. Foundation walls
shall have filled cells at 2-4" o.c, unless otherwise noted (see section)
L Contractor to provide for Form Board Surveg - Form Board Surveg
to be provided to Truss Compang prior to truss construction
1. Contractor to provide for soil test prior to construction and provide
a copy of soil test to architect for review prior to construction
S. ALL reinforcing steel shall be grade 60, meeting ASTM A-16 and
A-35 specifications. ALL Anchors to be A-301 steel.
9. Provide a minimum of 3" concrete protection at footings and
1-1/2" concrete protection at beams for ALL reinforcing bars.
#5 bar wart. w/ Thicken edge to 8"x8"
30" overlap SEE TYPICAL with concrete and
at each filled cell SECTIONS one 45 bar continuous
4" concrete slab with frbermesh OR
L"xL" #10/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
ill —IIII III IIII— i l4"w x 14"d concrete monolithic
PootI with (2) #5 bars cunt.
TYPICAL FOOTING DETAIL
SCALE 1/2" = 1'-0"
4" concrete slab with fibermesh OR
CxC 410/10 WWM on Io mil Visqueen over
clean compacted termite treated fill
45 bar cont.
Step per
7b1:A
Foundation plan
CJ �
10" 1 (2) #5 bars Cont. bottom steel
12"
DETAIL AT GARAGE STEPDOWN
12" x 12" concrete column
block Pilled with concrete
and (2) #1 bars wart. tied
into lintels above
To of Tooter
IL" below finished floor
SCALE 1/2" = 1'-0"
Verify house slab
height in field
30"x30"xl6" concrete
column footing with (4)
#5 bars each way
SCALE 1/2" = 1'-0"
SCALE: 114" = I'—O"
Termite Protection for New
Construction.
Soil treatment used for subterranean termite prevention
inside the foundation perimeter shall be done after all
excavation, backfilling and compaction is complete.
If soil area is disturbed after initial chemical soil treatment
area shall be re -treated with a chemical soli treatment
including spaces boxed or framed.
Treatment must be in accordance with the rules and laws
established bg the Florida Department of Agriculture and
consumer services.
Protective sleeves around metallic piping penetrating
concrete slab on grade floors shall not be of cellulose
containing materials and shall receive application of
termicide in annular space between sleeve and pipe.
4" concrete slab with frbermesh OR
6 x6 #10/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
WIIOM=
PORCH SLAB EDGE DETAIL
#5 bar vert. w/
30" overlap
at each filled call
Adjust curb height
based on gar. floor
slope.
45 bar in curb \
SCALE 1/2" = 1'-O"
4" concrete Blab with frbermash OR
6"xV #10/10 WWM on 10 and Visqueen over
clean compacted termite treated fill
0'-0" ® F.F.
14"
14"w x 14"d concrete monolithic
footing with (2) #5 bars Cont.
GARAGE CURB DETAIL
SCALE 1/2" = r-o"
2" x 6" PT wood secured with \
3/8"dia. x 6" anchor bolt at 18" o.c.
overhead door track secured to wood
jamb per manufacturer's product approval
Garage Door Jamb Detail
GARAGE DOOR TO WITHSTAND PRESSURES STATED NTS
IN PERMIT INFO BOX ON SHEET 41. SEE PRODUCT
APPROVAL FORM FOR MANUFACTURER MAKE AND MODEL.
0
0
Filled Cell Masonry Column With One °
#5 From Footing To Tie Beam Ln
Conc. Fill To Be 3000 PSI
See Floor Plan For Location
�i3r}
Single Filled Cell Column
NTS
Filled Cell Masonry Column With One
#5 From Footing To Beam Each.
Conc. Fill To Be 3000 PSI
See Floor Plan For Location
Double Filled Cell Column
NTS
Braden t Braden AIA, FA
Architects — Planners
411 S.E. Coconut Avenue
Tel (112) 281-8258
Fax (112) 281-8283
E-mail: brad enaiaacomcast.net
Stuart_ FL 34996 #AACOO0032
20'-0" 1 1 =1�I 1(Vrl i ir.__ X-'lI I 14'-0"
_ F
IMF J 3
©
"
i — — —— F1------�
Filled cell under
girder above
IQ I
FI I
I
Rear Patio/Slab
I
® Uj L—to be poured separate
From house
L ,
the slab.
I
N
I
23
r
Thicken footin to
I 24"w x 14"d x 2q4"L
r————— — — — — ——
I FI
I
I
I
I
I
FI
I
I 4" concr
6"x6" 410/h
clean cor
I
I
I
FI
I Cil
I
a R I under filled cell FI I
— Q �Q J under girder bearing.
I
Rear Patio/Slab to
be flush with bottom of
sliding door recess.
Slope 1/2"
I
I
I
I
I
I
32'-8"
I
,te slab with frbermesh OR I
> WWM on 6 mil Visqueen over
patted termite treated fill � I
FI I
I
I�
V I
O I
o I
II
I
� I I
�I
4'10 Steel
Ballard
Ofilled w/ Concrete1_I oO F
a ,
IwJI
I u I
I 11,0E I
E`
FI L EAt!
r — J
a
oo o
oL — — — —
M-01-773777777-
I LULLI
I (L
I I� N I ® ° — V — _ Recess for — J
°--------- --- ° ° ° o Garage boor ° °
L_
3 F
\ t 9'-O" 3'-5"
x 12" concrete column block filled
with concrete and (2) #1 bars vert. tied
into lintels above
I JLinne Building Corp.
The Grand C
Spanish Lakes
St. Lucie County Florida
REVIEWED FOR
CODE COMPLIANCE
ST. LUCIE COUNTY
BOCC
0
I
N
4'-O"
F007NG SCHEDULE
Description
14"W x 14"D
MONOLITHIC FOOTING WITH 2 #5 BARS CONTINUOUS
ksirs
12"W X 12"D
MONOLITHIC FOOTING WITH (2) #5 BARS CONTINUOUS
30" x 30"x IL"D
COLUMN FOOTING WITH (4) #5 BARS EACH WAY
8"W x 8"D
THICKEN SLAB EDGE WITH I #5 BAR CONTINUOUS
14"W x 14"D
With Curb at Garago
MONOLITHIC FOOTING WITH 2 U5 BARS CONTINUOUS - CURB a 0'-0"
MODEL: Date Drawn
12-4-11
GARAGE Drawn by:
a r 1 t on RIGHT C.C.U.
Checked by:
D.R.B.
Revisions :
Sheet Comm #
2), 12-21
OF 5
Provide #5 bare with min. 48 bar
diameters overlap into beam. Tie
filled cell steel into continuous
beam black steel.
Provide #5 bar act in pre -cast
lintel into beam where length of
the opening calls for 1t.
Simpson
HETA 20
Strap
truss to wall using Simpson
MGT with
hurricane anchor at each truss
5/8" dia.
threaded rod with min 12"
embedment
( 24" o.C.)
supporting Max.
PP g
into
(22)
beam either wet set or in
IOd nails into truss. Add
epoxy with
blocking to
1810
lbs. uplift
ETA 20�
r
truss leg per detail on
this sheet
R00F SHEETING
ATTACHMENT DETAIL
I. Minimum Nail Size = 8d ring shank (min. 2.5" long)
2. Minimum Screw Size = 48 x 2"
3. Minimum Sheathing Thickness 19/32" COX Plywood
4. Use nails or screws bas d on pressure for roof stated
1n permit info box on t�ese pans for zone 3
Ke
Area
Ede
Field
Fastener
Max.
Pressure
Zone I
611
411
Bidring shank
45 psf
Zone 2
6"
ed ring shank
lb p5f
Zone 3
4"
14
8d ring shank
84 psf
** Zone 3a
6"
4"
#8 wood screw
112.5 psf
** Use nails or s4rews based on res$ure for roof stated
in permit info box on these plans for zone 3
Concrete
/ Lintel
Column
Verifg with Plan
V,
Rebar
to Lintel
48 Bar Dia,
Min. Overlap
Provide Cast -Crete
SUB-OB/OT precast
lintel set in mortar
Min. 8" Bearing
-.1r
1
-tip �'�-/•-__
.}-A:�.r
i
r.l, 1.
Provide PT Buck
l,,ti
j;::; i
attached per jamb
details into filled cell
Precast
.
Sill
r,t
"'-Pared Filled Cell
Provide #5 bars with min. 48 bar
iameters overlap in Pilled cell. Tie
1lled toll steel into continuous
footer steel.
' ;; ' `J'' .'::`•..t',,'T' (secrate rooting
e footer schedule
for exact sizes)
DETAIL AT WINDOW OPENING IN
CBS WALL scale: I/2" = I'—o"
\\
12"x 12"
Column Block
J#�
Rebar
Attachment
NTS n
SINGLE PLY REAR GIRDER TRUSS
Nail 2' x 4" blocking to vert. leg of
truss with IOd x 1.5 nails at 4" O.C.
II Simpson MGT into wall using
dia. threaded rod set min. 12"
wet beam and 122) IOd nails into truss
TRUSS BLOCKING DETAIL
AT GIRDER STRAPPING
AT CENTER BEARING POINT
1/9" thick light textured stucco installed per
ASTM C 926 over ASTM D type 2 paper backed
wire lath nailed to substrate through one lager of
ASTM D Tgpe 2 felt paper using 8d Weds. Substrate
to be 19/32" COX Plywood nailed at 6" o.c. in field
and edges with IOd ring shank nails into studs.
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11651.12
26 ga. 5v crimp metal roofing attached to plgwood deck using #9 x 1.5'
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(tgpe 2) 30 lb felt underlayment installed with min. 4 side laps and 6" end
laps Fastened with corrosion resistant tin caps and with 1.25" ring shank nails
he
s aced 6 o.c. at all laps and two staggered rows 12"
o.c. in field. Attach
Wick
to trusses using attachment detail on this sheet
LINTEL SCHEDULE.
Mark
Window
or D
Unit
Width
Lintel
size
Caat-Crete
5 ecification
Rows of
'He Block
Above
"
Bottom
Steel
517eSteel
Top
size
Max
Gravity
Load
(PLF)
FUd
Max
Lateral
Load
(PLF)
L22
2'-2"
3'-V
8108-OBAT
1
#5
3069
1 1569
1024
L31
2'-V
31_�.
4'-0"
elille- IT
I
46
2561
1363
163
L45
+-5"
W-10'
8F8-OBAT
1
#5
1105
909
339
L60
5'-O"
V-0
8108-OBAT
I
#5
1238
836
121
1.60
6'-8"
T-0
BPS-OBAT
1
$5
1011
121
534
L80
V-O"
'l
8F8-IB/2T
1
#5
2
#5
152
Sell
512
L90
T-On
10'-6'
81=8-I13/2T
1
#5
2
#5
443
630
401
L90B
9'-O"
lo'-6"
ePIhIB/2T
ONE
I
#5
2
#5
1533
1183
401
LI00
10'-O"
ll'-4"
8P8-I5/2T
I
85
2
#5
582
494
452
LIOOB
10'-O"
11'-4"
SF16-1113/2T
ONE
1
95
2
#5
1366
1028
452
LI20
IT -On
1 13'-4'
8P8-I5/2T
I
#5
2
#5
411
428
324
L120B
IT-O"
IV-4"
SP16-IB/2T
ONE
1
#5
2
45
1015
110
324
L140
14'-0"
15'-4"
BP16-IB/2T
ONE
I
#5
2
#6
1250
609
259
LI60
I6'-O'
IT-4"
8P8-I5/2T
1
#5
2
#5
300
1 142
194
LILOB
IC -ON
IT-4'
1 alal6-I15/2"t
I ONE
I
#5
2
#5
960
1 600
194
- ALL LINTELS SHALL BE MADE BY CAST-CRETE.
- LINTELS SHALL BE FILLED SOLID WITH 3000 PSI CONCRETE
- REFER TO CAST-CRETE CATALOG FOR ALL INFORMATION REGARDING
LINTEL CONSTRUCTION, HANDLING INFORMATION, AND SAFE LOAD REQ.
REQUIREMENTS
- LINTELS OVER 14'-0" LONG ARE TO BE PRESTRESSED.
Simpson 14ETA 20 or equal
hurncane anchor at each truss
with (10) IOd x 1 1/2" nails —
( 24" o.c.) supporting Max.
18101be. uptilt
Aluminum Drip
Edge t Fascia
12"
2" x 6"
Kagcan full o vent vinyl eoPPit metalled
usingg 1/8, die shank x 15" long galv.
rooPmg nails with 3/8' dia. head per
product approval - see chart sheet #1
12" x 12' concrete column
block filled with concrete
and (2) #1 bare vert. tie
into lintel* above
thicken edge to 8"x8"
with concrete and
one #5 bar continuous
BEYOND
12
4
Aluminum Drip
Edge t Fascia
Flash and Counter
flash
Nail ledger to
gable end truss
with (2) IOd ils
at each web
fir -rib lath
vertical wood
a to provide
.ration into
3/4' penetration
members
5/8" thick light textured
stucco on typical concrete
block construction
Varies - see plan
#5 bar vert. w/
30" overlap
at each filled cell
Rear Patio/Slab to
be flush with bottom of
sliding door recess.
Top of footer
14' below finished floor
Step per foundation plan -
�l _ Slope per foundation plan
Poured Concrete or
concrete block wall
Poured Concrete or
concrete block wall
Concrete Anchors F
Manufacturers Specs
Psi
e Anchors Per
carers Specs
1/4"Men,
Min Pnnel
Size& per manufacturer
— See Tunrcal Stud Detail
1/8' x 3/32' Wing Nut w/
ve appropriate washer and spacing
i bper manufacturer's Details
6
a. ots`
i
I J E
1
i m
I E
1�
Stud Detail
Stud w/ Die Caat Zincnrs
Nickel Plated Wing Nut
Flush Mounted Shutter Detail
nts
Brace Gable and
with 2" x 4" SYP #2
eft back nailed to bottom
of top chords using (2) IOd
nails at each trues
RE -ENGINEERED WOOD TRUSSES
9 24"o.c. TYPICAL
( shop drawings b9 manufacturer )
O
w
0
CNI
to
to
� )i
1- as
a, Y_
Old
N
Heaa'C
a
1J1 0
=L Ia N
V � �
o � �
a 00
E_ c _
u ry
E
s
c
:1
y
R-30 blown fiberglass ,d
in bottom chord of trusses F
-1/2" drywall with smooth finish Al
Two rows of beam block filled with concrete
_and 11) #5 bar Cont. in each row. Substitute
precast lintel filled with concrete and (1) #5
bar cont, for bottom row over openings
1/2" drgwall over I" x furringg
strips at 16" o.c. with R4.1 ?1-foil
-insulation on typical 8" Block walls
All drgwall to be installed per FBC R102.3.1
and shall meet all pertaining ASTM codes.
Mortar to be Type "Mi' only. proportioned er FBC R601.1
and Mortar ,Joints shall comply with FBC 601.2.1.
Provide Our-O-Rock at all wet areas (ex. showers, tubs etc...)
Fill cell with concrete and O
!U #5 spacing
veil. (typicaU.
'Max.48unless otherwise
e notexceed
ood see foundation plan notes for — OVERHANGS AT 1'-0" UNLESS OTHERWISE NOTED ON THIS SHEET
age spacing at openings
4" concrete slab with flbermesh OR - ROOF PITCH AT 4:12 UNLESS OTHERWISE NOTED ON THIS SHEET
6"xe" #lo/lo wwM on 6 mil Vlaqueen over — TRUSS SHOP DRAWINGS TO BE PROVIDED BY MANUFACTURER
clean compacted termite treated fill - ANY CHANGES TO THIS PLAN SHALL BE SUBMITTED TO THE
6WAidgm FAA
I
MINIMA
F
OVA
Inew
FA! arIMA' ",
I AN
WA OA "A
600WA A
mill
FAA
IN
11
NFA
�
Nwam-'o,
UA
rem
A
WEN
FA
REVIEWED r-O
CO DE COFMPLLANCE
T„ LUC HE COUNTY
OCC
0
LU
Brace Gable end
with 2" x 4" SYP #2 min.
--aft back nailed to bottom
of top chords using (2) IOd
nails at each truss
=1 I I I1 I I I1 I I I IIII I ' IIII1 I I I=1 I I I=1 I I I=1 I I ICI-1=U 111 I I 1=1 I I I,,, I I I i=
:;IIII=IIII=III = ; `:;': IIII=IIIIIIIIIIIIIIII=IIII IIII I i �_
IIII I I I I—IIII ..r _� _� ...'' I I l l � l 11 I I I I „. ,IIII I I I I_I ► I I� I 11�"III I Fl
IIII ;,IIII ,�Il it-l�i�-rill 3 TLiwcal Section at Front
-------------
ETA 20
-------------
FLAN
I
m
ARCHITECT FOR APPROVAL IN WRITING PRIOR TO STARTING CONSTRUCTION.
ALL TRUSS TO TRUSS CONNECTIONS BY
TRUSS MANUFACTURER
ARCHITECT TO REVIEW TRUSS SHOP DRAWINGS PRIOR
TO CONSTRUCTION FOR LAYOUT AND UPLIFT VERIFICATION
Porch - CONTRACTOR TO PROVIDE FOR FORM BOARD SURVEY AND TO PROVIDE
)11 = 1i_nlr FORM BOARD SURVEY TO TRUSS COMPANY PRIOR TO TRUSS CONSTRUCTION
PANEL
"A"
Poles
BR
Load
Wire
Description
arc#
tiro#
Description
Wire
Load
pR
Poles
2
40
'1.0 kw
#a
A/C comp
1
2
AHU
#10
3.5 kw
30
2
3
4
2
30
4.5 kw
#10
40 gal. water HTR
5
6
Range
#6
12.0 kw
50
2
I
a
1
20
1 1.9 kw
#12
Pump
9
10
Drilar
#10
5.0 kw
30
2
II1
12
1
20
1.6 kw
812
13
14
Dishwasher
012
1.2 kw
20
1
1
20
1.5 ku
#12
Microwave
15
16
Refrigerator
#12
1.2 kw
20
1
1
20
1.5 kw
#12
Kitchen S.A.C.
m
Is
Recepte
#IZ
20
I
1
20
i.5 kw
#12
Kitchen S.A.C.
19
20
Recepts
#12
-
20
1
I
20
1 1.2 kw
#12
Clothes Washer
21
22
Rscapts
#12
20
1
1
20
0-81 kw
$12
Garage Door Opener
23
24
Recepts
#12
20
1
1
20
1,4 kw
#12
25
26
Recepts
#12
20
1
1
20
1.92 kw
#12
21
20
Recepts
#12
20
1
1
20
*12
General Lighting
24
30
Racepts
#12
-
20
1
-
1
20
#12
General Lighting
31
32
Recepts
#12
20
1 1
-
1
20
#12
General Lighting
33
34
Exterior GFCI
#12
-
20
1
-
1
20
#12
General Lighting
36
34
Bathroom OF[
912
20
1
1
20
#12
Smoke Detectors 1
31
1 38
General Lighting
#12
-
20
I
1
20
#12
Bathroom GPI
39
40
General Lighting
#12
20
I
s are
41
12
s are
PANEL "A" LOAD CALCULATION SHEET
Load Description
Qty.
Watts
Total(Watts)
General Ligfiting_ (3, watts sq:.ft.).........................
$maIl.,Appiiance.Circultl,$), ,,,,,,,,,,,,,,,,,, ,,,,,,,,,,,,,,
Range
Refr19erator ............... .................. ...............
Microwave
.Di . sh Washer.........................................I.........
Clothes..Ulasher,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
Clothes..Dryer,,,,,,,,,,,,,,,,,,,,,,,,
Water Heater ...............................................
Water Pump......... ..
Garage. poor,Opener......................... ............
1135
3
5r205
2
1,500
3000
1
12,000
12 000
1
1,200
1.200
1
1500
1500
I
1.200
1200
1
1200
1200
1
5,000
5,000
1
4,500
4,500
I
1,8100
I,d00
I
810
810
Total Watts
1 31,415
First 10000 Watts e100%
1
10,000
10 000
Remainder 21,415 e40%
1
O
10,966
Electric Heat or A/C 10,000 eL5%
1
10,000
10,000
Calculated Load
Watts
30.9L4
Voltage
240
Calculated Wattage Divided by Voltage = Total Amps 129.03
Panel Size Required = 150 Amps
Electrical S mbol Legend
$
Single Pole Switch
®
Recessed Can Light
S3
Double Pole Switch
®
Egeball Recessed
wg
Push Button Switch
0"
Exhaust Fan
-09
Duplex Outlet
Ceiling Mounted Light
Special Receptacle
O-
Wall Mounted Light
-.8Waterproof
rc
ground fault circult-
interrupter
PC
Light with Pull Chinn (attic)
®
Floor Duplex Outlet
©
Computer Connection Jack
en
Carbon Monoxide Detector
412
Flood Light
T�}
Thermostat
m
Electrical Panel
®
Central Vac
8
I Electrical Meter
Q
Smoke Detector
Ceiling fan
©
Television Jack
t❑
Telephone Jack
AC C
A/C Disconnect
®
I x 4 Florescent Light
®
2 x 4 Florescent Light
®
Speaker Hook -Up
1
171
llntercom
H.B.4-
Vent _thr_u
---
PATIO/SLAB
1
1
GrtR AT
R OM
I
I
I
Center Registers
I19 CFM on ceding fan "al CFM
IOxIOXi 1 XIOxl
DINING
ROOM
IL"
1
I
232 CFM
1
12x6x,
I
L Jtki .
SECOND
i/
,
BEDROOM
I
12xl2x8
I 1
B/A
[J
143 CFM
IOxlOx6
MASTER
BEDROOM
143 CFM
IOxlOx4
rs ra
ICJ r ,ICJ
12Ire-If I B/A C)
LOSET
Sx4x4
12'r
i'��---
�
i Q
a I
10•
�g K
-- - --J
COVERED
PORCH
= JUNCTION BOX TO SUPPORT A BAN
�EC�4NIC/4L L/4YOUT
= THERMOSTAT LOCATION
B/A = BALANCED AIR
Electric Notes:
SCALE: 1/4" = 1'-0"
I.
2.
Use copper Wire onlg, no aluminum.
Provide and wire all required smoke detectors.
I1. It Is not the intent of these plans to show every minor detail
3.
Contractor to verify location of electrical
of construction. The contractor shall furnish and install
all items for a complete electrical system and provide all
4.
service and provider.
ALL fans shall be on a rheostat.
the requirements necessary for the equipment to be placed in
5.
paddle
ALL bath and kitchen receptacles to be GFI protected.
proper working order.
18. All work shall be done in accordance with the N.E.C. and
6.
ALL exterior outlets to be WP/GFI protected.
shall comply with all local codes and ordinances, and shall
1.
Recessed cans to be installed per NFPA requirements.
meet all standard requirements of the local electric utility
S.
AFCI receptacles are required in all rooms except
and telephone company.
Kitchen, Bathrooms, and Garage.
9.
10.
A/C Return Air Balance Must comply w/ FBC RM1402
A/C Refricierant lines that are run thru slabs must be
19. The electrical system shall be completely and effective)
sleeved in PVC
9 quirerounded as required b the latest edition of the N.E.
9
11.
ALL A/C Equipment shall comply with energy calculation
20. All material shall be new and shall bear underwriters'
12.
All work shall be performed bg a licensed electrical
labels where applicable.
contractor, the completed system shall be fully operative.
13.
Contractor shall pay for all fees, permits, testing, and
21, All equipment and panel sizes shall be verified before
inspections including blower testing where required.
ordering. The contractor shall provide circuit routings to
14.
All work shall be coordinated with other trades to avoid
suit the Job conditions.
interference with the progress of construction.
15.
All required insurance shall be provided for protection
22. Furnish and install all fixtures as called for on the plans
against the public liability and property damage for the
or as selected bg others.
duration of the work.
16.
Contractor shall guarantee all materials and workmanship
23. All raceways and pipes placed in or through any concrete
free of defects for a period of not less than two years from
slab shall be spaced a minimum of three diameters of the
the date of acceptance or certificate of occupancy, or one
largest conduit or pipe from any other service.
year from closing sale of house.
Correction of defects shall be completed without additional
24. All exposed wire below 9'-I" shall be installed 1n metal EMT
charge and shall include replacements or repair of any
conduit.
other phase of installation that may have been damaged.
25. Dryer Vents to be installed per FBC RMI502
22' x 54" 1
Attic Aces"
L_____I
with light
311 4 CFM
BAT _ Sofflt
CFM
190 Amp , f Meter
Panel AI
GARAGE
r-----------------,
I I
1 I
I I
I I
I I
i I
I I
I I
I I
I i
I 1
I I
#2/0 Aluminum feed
I h" Conduit
2" PVC t FPL
2"
ELECTRICA
A/C disc.
ACC
PANEL
nr15#cont!PTaDariin slab
L RISER
- Contractor shall use AL-CU Landing lugs. NTS
- Contractor shall torque lugs I.A.W.
manufacturers recommendations which
shall be verified prior to construction
Braden it
Braden AIIA, FA
Architects
- Planners
411
S.E. Coconut Avenue
Tel
(112) 281-8258
Fax
(112) 281-8283
E-mail:
brad enaia*comcast. net
Stuart. FL
34996 UAAC000032
H.B.
Exhaust Duct
Thru Soffit -
Wire For
Front Post
Light
/Govered Porch �\
/ `
MASTER
r BEDROOM
I
I
WP GFCI
I
Y 5-/ V ry / J
r
GAR AT
Smoke / Carbon
ROOM Monoxide
Detector
Combo
1 S
I
I -
11 ��-L'OSET
II I
11 I
DINING ROOM 1 _
I GFCI
If - -
1 I �� G CI ,,-I / IGFCI 4FCI
I O
TJ I\ ►I
1 KITCHEN
J _ smokv_ / CnrbeL
Monoxide Detector
C Hmee S Combo
3'-2" 3'-2" 24" \
so M cl
F
i w
( enter ?
ND %
BEDROO
Of
19/
B �\
1 � \
WP GFCI /
\ tQVERED
P 6R� Ffi ' n
W 0
61.1410,
1 IN
22" X 54"
Attic Aces"
with light rL,\ _t I
J
Optional I arl0 Amp
panel location I / Panel
Pull chain /
light in attic /
42"h GFCI
GARAGE
Garage
Door
Opener
r-----------------,
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
Exhaust Duct
Thru Soffit
4" Exhaust
Duct Thru
Wall
WP GFCI
Install oulct
N under disc.
Q not shown for
�� clarity
A/C
eter
ELECTRICAL FLAN
SCALE: Vq" = I'-O"
Wunne Building Corp.
T1 e) Grand C
Spanish Lakes
St. Lucie Countg Florida
)Z�Poat Light with
I Photo cell
0
I
N
arlton
FBC 2
Total Attic Space = 2124 sq. ft.
Venting Ratio 1/150 = 14.16 sq, ft. required
Provide A Continuous Vented Soffit
MODEL:
Date Drawn
12-4-11
GARAGE
Drawn by:
RIGHT
c.c.u.
Checked by:
D.R.B.
Revisions
Sheet I Comm #
-� 12-21
OF 5
A=LIFE SAFETY WARNING
This symbol identifies Life Safety Warnings that should be read'
given special attention by all persons installing trusses.
5PAGING NOTE
ALL TRUSSES ARE TO BE SET
AT 2'-0: ON CENTER
EXCEPT AS NOTED
MULTIPLE PLY TRUSSES MUST BE
ASTENED TOGETHER PER ENGINEERING
BEFORE SETTING. REFER TO
ENGINEERING DRAWING TO DETERMINE
IA IF MULTIPLE PLY.
F9
DON'T LIFT TRUSSES
WITH SPANS LONGER THAN
30' BY THE PEAK.
CONSULT BCSI
30' Span or less 30' to 60' Span
60 degrees Sprea er Bar
or less
41 1 /2 ---►
Tag Line spar approx.
REFER TO BCSI
Truss must be set this way If crane used.
Truss Is an example, our truss may not match.
nsist crane operator sets truss this way.
}fag ,__Approx 2/3 to
Line 1/2 of Span
REFER TO BCSI
ass must be set this way if crane used.
This is an example, truss may not match.
Insist crane operator sets truss this way.
All load bearing walls, headers,
beams & lintels must be in place
at indicated height before trusses
A are installed. A
A I I-R " olli V Il I Il F2 N O T E
UNLESS NOTED ELSEWHERE ON THIS LAYOUT, THESE TRUSSES
ARE NOT DESIGNED FOR AIR HANDLERS IN THE ROOF OR FOR
ANY OTHER A/C REQUIREMENTS. THIS MAY BE IN CONFLICT
WITH BUILDING CODE AND A/C DESIGN REQUIREMENTS.
CONSULT WITH BUILDING DEPARTMENT AND A/C CONTRACTOR.
U REPRESENTS A HANGER
For Truss to Truss
Connections see
hanger/connector
schedule in engineering
package.
Carrying Girder
'Nails must be as
shown. Guide tabs
Dome angle nails.
SEAT PLATES BY CHAMBERS
0
INDICATES LOAD BEARING WALL
REQUIRED BY TRUSSES
SUPPLIED BY BUILDER
AT A HEIGHT OF I"
ABOVE FINISHED FLOOR
12
4.00 -
i
upset=l/4" heel=315/16"
PLUMB CUT END
k 2 x 4 Top Chord
WALL HEIGHT 6'-1"
TYPICAL END DETAIL
12
4.00
12 2.00 $ B- 1—
upset=1/4" heel=315/16"
PLUMB CUT END
2 x 4 Top Chord
WALL HEIGHT 6'-1"
END DETAIL: A
IA
ARRANGE WITH CRANE OPERATOR IN ADVANCE
FOR A SPREADER
BAR OF 17' - 23' IN L=NGTH
®
Do not stand
on trusses until they
are
braced
per
BCSI
& properly
nailed
to
straps &
hangers
GARAGE LEFT
GARAGE RIGHT
REVIEWED
87'" LUCIE CC
*. c
OR FABRICATION AGREEMENT
TRUSSF�,.GWNOT BE STARTED UNTIL THIS AGREEMENT IS SIGNED & RETURNED
ttd�dgel;dcrlptlon of the property where the trusses will be Installed is:
On erblgned acknowledges and agrees:
1. Trusses will be made In strict acoordanbe writ this 4uss placement diagram layout,
which is the sole authority for determining.suxessful fabrication of the trusses.
2, All dimensions In this layout have been veriAed is the undersigned.
.3, Unless written notice Is provided by certlAod mall to Chambers Trues whhln ten (10)
days of delhrery the undereigned agrees that no backcharges wltl be allowed. In the event
such written notice Is fuml$hod Chambers Truss shall have three (3) buaa�tnness days in which
'to begin repalre required, or to 1dg: je othettrussss, at Chambers optl�n.
4. The undersigned acknowledgss rebelpt of "SCSI 1 0 summary sheet by TPI & WTCA.
5. Delivery is to Job she, h Is the buyees' nesponsibllhy to make the Job site suitable for
delivery. Chambers Truss has the sole authority to determine the suitability of the Job site of a
pordon of the Job she for delivery, Chambers Truss will be responsible for dump delivery only.
The buyer Is
responsible for additional deliver + expenses If Chambers Truss has to redeliver
because job she Is not prepared for delivery or buyer Is not prepared for delivery of trusses,
Buyer Is responsible to Chambers Trues for towing costs due to site condltlons.
S. Pike as shown In paragraph 7 below Is subject to change If any changes are. made Inthis layout. A $50 per hour fee for revialone may be charged by Chambers Truss.
- , 7: This Is a PURCHASE ORDER to Chambers, Truss of the sum agreed to. or V nor
agreement a reasonable price. Invoice will be made on delivery and paid within terms of not
on delivery. Invoice may be made at scheduled date of delivery If buyer cannot scospi'
delivery of fabricated busses. The undersigned agrees to pay Chambers.Tfuss reasonable
attomey's fee for collection$ In event of payment not timely made. 1.12 % per month sefvjce
charge will be added for all sums not paid within tense,
. 8, signature or Initials anywhere on this sheet constitutes agreement to all terms heroin.
9, In consideration of Chambers Truss extending credit for this material the undersigned
unconditionally guarantees payment when due of any and all Indebtedness owed to
'Chambers Truss by any entity receiving material and the undersigned agrees to pay such
Indebtedness Including attorneys fees, If default In payment for material be made by the
recipient.
10. In the event of any Ihlgallon concerti this agreement, the Memo furnished hereunder
or payments referred to herein, the, parties agree that the sole venue for any such action will
be Saint 6001e County, Florida.
11. Design responsiblifies are per "National Standard And Recommended Guidelines On
Rasponslbllltles For ConstnxUon Using Metal Plate Connected Wood Trusses
ANSVTPVWTCA 4 - 2002
DATED
SIGNED
FOR Tf1LE
Aspreaderbar maybe III per"BCSI'I-03"ttfpwmtkt ytfrdamage,.
Multiple ply trusses must be fastened together per engineering
before they are sell failure to do so can result In roof collapse.
Temporary and permanent bracing are required and can save life
and property and Is the responalbility of the truss erector"
Study the contents of the Information packet Included on delivery
before settling trusses,
TnammustbesdwWbracedpsrdestgnmpleuerdWu &*arms.
Trusses must be set plumb and square
Do not set bunks or stack of plywood, roofing material or any
other colteentreted loads on busses, this can cause collapse.
DO NOT SET TRUSSES USING THIS LAYOUT
USE LAYOUT DELIVERED WITH TRUSSES TO SET TRUSSES
CHAMBERS TRUSS INC
3105 Oleander Avenue
FortPlercej Florida 34982-6423
800-551-5932
Fort Pierce 772465.2012 Fax 771 465-8711
Vero Beach 772-569-2012 Stuart 772-286-3302 '
rar-� Oill reuauccostronsS'CAM
The Architect'% or Architeot's roproaril .:,..,...;
shop drawing approval Is NOT a
"double check" of the contractor,:
The contractor shall remain responsible
for checking field moasuromants and
other construction crlteria. Architect's
approval covers general roof shape,
review of truss strapping, and loadln� on li
structure from gravity and uplift loads and
their re cl ire locations.
Approved t3 : ,t / �r
Date: ... ?YI�1 —__
Braden &Braden A,I P.A.
92.0/93.2 MITEK 4.2
DESIGN CRITERIA
County
SAINT LUCIE
Building Department
SAINT LUCIE COUNTY
Wind Design Criteria
ASCE 7-2010
Wind Design Method
MWFRS/C-C hybrid Wind ASCE 7-1
Roofing Material
Shingle or Shake
l
Loading in PSF
Roof R.D.L.
FcI
>, _
w I
Top Chord Live
20
w
c
Top Chord Dead
7 4.2
w
•2.
Bottom Chord Live
10 Non -Concurrent
E r1
°
Bottom Chord Dead
10 3
E
TOTAL Load
37 7.2
a
3
Duration Factor
1.25
R
G
Wind Speed
165mph
_>
Top Chord C.B.
Sheeting by builder.
1:0
Bottom Chord C.B.
Sheeting by builder.
Highest Mean Height
14'1
v
Building Type
ENCLOSED
Building Category
II:Non Restrictive
Exposure Category
C
Barrier Island
No
Conforms to FBC 2017
W
U)
Q
Verify DESIGN CRITERIA shown above with the
building department and your engineer.
Design Criteria is the responsibility of the
Building_Designer and/or Enoineer of Rernrrt
Chambers Truss Inc. Drawing Name: M11323
Scale: 1 /4 = 1'
72 total trusses, 13 different trusses.
M14: SAE ACAD: SAE Reviewed By:
Date:04/24/12 Revised:02/21/18
FOR
WYNNE BUILDING CORP.
DESCRIPTION:
62' GRAND CARLTON III 76l
PAGE 1 of 1 CUSTOMER INITIALS EACH PAGE
13 TRUSS DRAWINGS ARE ATTACHED TO LAYOUT
M 11323 la p/ -4,�