HomeMy WebLinkAboutCONCRETE PAD PAPERWORKGENERATOR I i PAD i \ THICKNESS ISOMETRIC VIEW PAD DIMENSIONS: CONCRETE PAD GENERATOR i GENERATOR UNIT BY o SEPARATE SUBMITTAL (SEE SCHEDULE FOR n MINIMUM WEIGHT REQUIRED) TJ 54" LENGTH -+ PLAN VIEW it' CONCRETE PAD I , L-._,�-�•-_ _ �,: v / ROAD MESH IASTERFIBER L 3'MIN' MAC100 q,;MINN:F AMERICAST GENERATOR CONCRETE PAD N-GRADE APPLICATIONS ONLY) JUN 2 0 2019 I� - AMERICAST 'f Permitting -�- ST. Lucie County, ']EADH INAtDmetOwt" _ '-�� S Y FkD TA%iS011fllNl �CEtIIa F59p.10afDlAT � �• S]W PYns4,ARP Nrne,R N9C ; 1W,T20)1-199 F¢Tl]iN6L9- - I a- j�E nl�`iideAa.,tl�x;nmelnMewilQtllllnboeea GENERATOR TABLE: HVHZ OR NON-HVHZ s r" RISK EXPOSURE (EXP) RISK' EXPOSURE [EXP) RISK EXPOSURE (EXP) COUNTY I C D II C D1" illl IVi �° uIC-' .D3R1 P. BEACH 150 MPH 30.44 Psf 36.94 Psf 170 MPH 39.09 Psf 47 44 Psf, ASS MPH 43 83 Psf 53.19 Psf. BROWARD 156 MPH 32.92 Psf 39.95 Psf 170 MPH 39.09 Psf 47.44 Psf, ,180MPH 43:83 Psf 53.19 Psssf, MIAMI-DPDE 165 MPH 36.83 Psf 44.69 Psf 175 MPH 41.43 Psf 50.28 Psf 186 MPH 46.80 Psf 56.80 Psf fr: .�f ', BRAND &MODEL CAPACITY - WIDTH 1 t LENGTH s -HEIGHT N'' WEIGHT; /ALLOWABLE J PRESSURE COMMENTS Generac 005871 & 005883 30 KW 25.001 '. 48 00 29i00 3871bs: 41.43 Psf EXP C 175 MPH & D 156 MPH Generac 005872 & 005884 14 KW 2500'; 4800 29.00 43916s/'N47.44 Psf EXP C 186 MPH & D 156 MPH Generac 6459, 6461, 6462 16 KW 25.00"� 4800" '29.00 `5131bs "47:44 Psf Generac 006721 16 KW 25.00" 4800' 29.00 �448Its 47.44 Psf Generac 005873 & 005885 17 KW 25.00 ' 48.00 29.00 455.Its 47.44 Psf Generac 005874 & 005886 17 KW 25:00"� 44910 0 i 29.00 . -4�21Its- '4 P 44 Psf'^ Generac 005875 & 005887 20 KW 25.00" r48.00.., t29.00 -; 451•IbS-s 14744 Psf Generac 006729 & 006730 20 KW 25.00"'"48.00 "L)29.00" t5161bs- �47.44 Psf Generac 006551 & 006552 22 KW 25.00" 48.00" '29.00" 5261bs 47.44 Psf Kohler 14RES&20RES 14-20 KW 26.00" 49.00" 29.00" 50016s 47.44 PSI GE 403236E&40324GE 13 KW 35.00" 39.40" 39.00" 540 its 39.09 Psf EXP C 170 MPH &D 156 MPH GE 04038215KW 15 KW 33.00" 48.00" 30.50" 484 His 43.83 Psf EXP C 180 MPH &D 156 MPH GE 04037817KW 17 KW .00" 30.50" 484lbs 43.83 Psf GE 40330GE & 40331GE 20 KW .00" 30.50" 600Its 43.83 Psf & Stratton 040243-0 10 KW .00" 34.00" 4301bs 43.83 Psf -Briggs Briggs & Stratton 040302-2 12 KW .00 " W337550.00" 31.60 " 5071ts 41.43 Psf EXP C 175 MPH & D 156 MPH Briggs&Stratton 040303-1 15 KW .00" 31.60" 562 lbs 43.83 Psf C 180 MPH & D 156 MPH Briggs &Stratton 040304-1 I8 KW .00" 31.60" 568 lbs 44.00PsfEXP Briggs&Stratton 040305-1 20 KW .00" 31.60" 570Its 44X0 Psf Generac7035, 7036, 7037 16 KW 2S.00" 48.00" 29.00" 4061bs '47.44 Psf EXP C 186 MPH &D 156 MPH Generac 007038&007039 20 KW 25.00" 48.00" 29.00" 448 Its 47.44 Psf Generac 007042&7043 22 KW 25.00" 48.00" 29.00" 46616s 1 47.44 Psf la W "` 'GENERATOR MOUNTING CONFIGURATION: GENERATOR GENERATOR ATTACHMENT BASE OR SIMPSON A24 ANGLE BRACE W/ (4) #10 SS 316 SELF -DRILLING T@ aka" GENERATOR (SEE CONCRETE PAD ID SCHEDULE FOR DIMENSIONS REQUI REQUIRED) 4, n �32" WIDTH ,I-54" LENGTH SIDE VIEW I FRONT VIEW (SEE aw. WIND DESIGN REQUIREMENTS: (BASED ON ASCE 7-10 & FLORIDA BUILDING CODE SIXTH EDITION (2017)) AT -GRADE SIGN METHOD ULTIMATE DESIGN WIND SPEED Vult = 186 mph NOMINAL DESIGN WIND SPEED Vasd = 144 mph RISK CATEGORY = III INTERNAL PRESSURE COEF = N/A EXPOSURE CATEGORY = D WIND DIRECTIONALITY FACTOR Kd= 0.85 ENCLOSURE CATEGORY = N/A HEIGHT H = AT GROUND GUST EFFECT FACTOR = 0.85 PRESSURE AT HEI T h - 7 Ib/ft2 FORCE COEFFICIENT Cf = 1.44 Nib WIND PRESSURE: B� P-QGENERAL NOTES -St' ude_CounW 1. THIS SYSTEM HAS BEEN DESIGNED AND SHALL BE FABRICATED IN ACCORDANCE WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE SIXTH EDITION (2017). 2. REQUIRED WIND LOAD DESIGN PRESSURES CALCULATED FOR USE WITH THIS SYSTEM SHALL BE DETERMINED UNDER SEPARATE CERTIFICATION ON AJOB-SPECIFIC BASIS IN ACCORDANCE WITH THE GOVERNING CODE. SITE -SPECIFIC LOAD REQUIREMENTS AS DETERMINED IN ACCORDANCE WITH THE APPLICABLE BUILDING CODE 'SHALL BE LESS THAN OR EQUALTO THE DESIGN PRESSURE "ASD" CAPACITY.YALUES LISTED HEREIN FOR ANY ASSEMBLY AS SHOWN: 3. DIMENSIONS ANDiWEIGHT OF UNITS SHALL',CONFORM TO SPECIFICATIONS STATED HEREIN� '` /'-' ' ANCHOR TO PAD SCHEDULE: 4. UNITS MUST BE CENTERED ONAAD WITH OPPOSITE SIDES ISUBSTRATE i DESCRIPTION CONCRETE:R)-3/e°0 TLTEN HD (6000 PSI OR EQUIVALENT, MIN.) 2-3/4"FULL EMBED O CONCRETE, 3" MIN EDGE DISTANCE, 6" MIN. SPACING TO ANY ADJACENT ANCHOR. NOTES: 1. ANCHOR I/e" SIMPSON TITEN HD, SEE ANCHOR SCHEDULE 2'x3'x%fi GALV. STEEL - WASHER RUBBER VIBRATION PAD - •••,VIBRATION PAD,I 1 , \ �� Z CONCRETE PAD - '�- 6,000 PSI LIGHTWEIGHT CONCRETE MIX F CONCRETE PAD 1 /' 6,000 P51 ✓ Nf ` LIGHTWEIGHT MASTERFIBER `> MAC 100 J & ROAD MESH t y fCONCRETEMIN I (, i"",L��! I � � FOAM CORE a i.,.,y DISTANCE DEPEND ON BASE LENGTH, NO LESS THAN 2". IEDCATOR 2. X DISTANCE 3" FROM UNIT T EDGE TO CLIP. 2 3. Z DISTANCE DEPEND ON GENERATOR BASE WIDTH, ry0 LESS THAN ' ANCHOR REQUIREMENTS HAVING EQUAL CLEARANCE A,MINIMUM DISTANCE FROM UNIT TO PAD EDGE IS SPECIFIED. 5. CALCULATIONS MADE USING LIGHT -WEIGHT ONCRETEI2S PCF 6. THE AREA UNDER CONCERETESLAB ON.GROUND SHALL HAVE ALL VEGETATION, STUMPS, ROOTSi,A.NMFOREIGN MATERIALS REMOVED PRIOR TO INSTALLATION ON COMPACTED SOIL AS VERIFIED BY OTHERS. I("""s9Fro iE`= ')IJq 41 ^ 7. RESISTANCE TO,SEIDING OFJTHE PAD C T-HEGROUND�ISINOT PART OF THIS DOCUMENT AS SOIL CHARACTERISTICS AND PAD PLACEMENT VARIES_--:;�k 8. ELECTRICAL GROUND, WHEN REQUIRED, TO BE DESIGNED & INSTALLED BY OTHERS. ALL MECHANICAL SPECIFICATIONS (CLEAR SPACE, TONNAGE, ETC.) SHALL BE AS PER MANUFACTURER RECOMMENDATIONS AND ARE THE EXPRESS NNTITY PER LONG SIDE AS RESPONSIBILITY OF THE CONTRACTOR. AND EDGE DISTANCE 9, ENGINEER SEAL AFFIXED HERETO VALIDATES STRUCTURAL WISHES, IF DESIGN AS SHOWN ONLY. USE OFTHIS SPECIFICATION BY CONTRACTOR, et. al. INDEMNIFIES & SAVES HARMLESS THIS IMUM.EDGE DISTANCE ENGINEER FOR ALL COST & DAMAGES INCLUDING LEGAL FEES I ANCHOR SCHEDULE. SPACING TO & APPELLATE FEES RESULTING FROM MATERIAL FABRICATION, T ANCHORS. hr'A SYSTEM ERECTION, CONSTRUCTION PRACTICES BEYOND THAT iUFACTURER'S WHICH IS CALLED FOR BY LOCAL, STATE, & FEDERAL CODES & IN INSTRUCTIONS TO FROM DEVIATIONS OFTHIS PLAN. :HOR9., 10. WATER -TIGHTNESS OF EXISTING FINISHES SHALL BE THE FULL RESPONSIBILITY OF THE INSTALLING CONTRACTOR. CONTRACTOR SHALL ENSURE THAT ANY REMOVED OR ALTERED WATERPROOFING MEMBRANE IS RESTORED AFTER "L8 R fi ,r-- FABRICATION AND INSTALLATION OF STRUCTURE PROPOSED )+•-=S 3?y� 4 ; HEREIN. THIS ENGINEER SHALL NOT BE RESPONSIBLE FOR ANY WATERPROOFING OR LEAKAGE ISSUES WHICH MAY OCCUR AS WATER -TIGHTNESS SHALL BE THE FULL RESPONSIBILITY OF THE INSTALLING CONTRACTOR. 11. THE ROLE OF THIS ENGINEER FOR THIS PROJECT IS THAT OF SPECIALTY ENGINEER AND NOTTHE ENGINEER OF RECORD. CONSEQUENTLY, THE ARCHITECT/ENGINEER OF RECORD SHALL ' BE RESPONSIBLE FOR THE INTEGRITY OF ALL SUPPORTING SURFACES TO THIS DESIGN WHICH SHALL BE COORDINATED _ BY THE PERMITTING CONTRACTOR. �""-- 12. THIS DOCUMENT IS GENERIC AND DOES NOT PERTAIN -TO ANY SPECIFIC PROJECT SITE. INFORMATION CONTAINED'HEREIN IS RA R UPPL D TA AND MEASUREMENTS B ED ON CONY CT O S IED A - ENGINEERING EXPRESS SHALL' NOT BE HELD RESPONSIBLE OR LIABLE IN ANY WAY FOR ERRONEOUS OR INACCURATE DATA rI OR MEASUREMENTS DIMENSIONS ARE SHOWN TO ILLUSTRATE - DESIGN FORCES AND OTHER'DESIGN CRITERIWTHEY MAY `T VARY SLIGHTLY, BUT-MUSTREMAIN WITHIN THE LIMITATIONS SPECIFIED HEREIN. WORK SHALL BE FIELD VERIFIED BY OTHERS PRIOR TO CONSTRUCTION ENGINEERING EXPRESS SHALL BE NOTIFIED AND * LGIVEN AN OPPORTUNITY TO REEVALUATE OUR WORK UPONIDISCOVER.Y OOF ANYj I\. a�-- �2"-} INACCURATE INFORMATION PRIORTO MODIFICATION OF EXISTING FIELD CONDITIONS*AND,_ABRICATION AND " INSTALLATION OF MATERIALS. ALTERATIONS OR ADDITIONS TO THIS DOCUMENT ARE NOT PERMITTED AND INVALIDATE OUR CERTIFICATION. 13. EXCEPT AS EXPRESSLY PROVIDED HEREIN, NO ADDITIONAL CERTIFICATIONS OR AFFIRMATIONS ARE INTENDED. NK. L.7_7�kQrj4li BEN.NARDDO, P.E. I NK L BEBENNARDO, P.E. ,. 6549 10 FORt EEIT Ub ICE:!FTHISIS SDOE ORIG r CONTAIN AN ORIGINAL 'NATURE &ENGINEER SE HERE 15 A OIGUAL NATURE ON SHEET 1, THIS iET IS PART OF A DIGUALLI NED FILE, SHALL REMAIN It UAL FORMAT, & PRINTED •IES OF THIS DOCUMENT "e NOT CONSIDERED SIGN D SEALED, IF THERE IS NO UAL SIGNATURE ON SHEET THIS SHEET DOES NOT Z w N Z �a FT ® wM mqE 3O LL� W ui .F.M m uy U7Ji�nMm WED "(D ',-X w 4 W Zry OW w26f r� nn �nl uLL 0QwgwL�LL %C pL BI Z WWtt 7 a z a> Dzww O J w 0 O w�o- 0 U) W aMw p w ui 10 p o a z0 w H � J J Q U_ Nw Y 2 O w Q m F U w W ^, 0_W w VI a/ a + N aIn p W ate' -Z La M O a g mw..3a Q Ul Y K w .Na � m w C C7 RC K O 'o o Gib Y o �pY v S;mm �o Wob 5 �w= 3000 0555 �w��gga 6�w3� 1 17-3961.1 1 Cd L-