HomeMy WebLinkAboutENERGY EFFICIENCY CODEr
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Ditullio Residence
Builder Name:
S{OMNED
Street: Lot 17 & 19 Gopher Ridge Road
Permit Office: St. Lucie County
�1V
State, Zip: Fort Pierce , FL, 34982
Permit Number:
Omer:City,
Omer: Ditullio Residence
Jurisdiction: St. Lucie County
v
�^�e11Y®�
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1730.9 scift.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1534.90 ft'
b. Frame - Wood, Adjacent
R=11.0 196.00 ft'
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (1975.0 sgft.)
Insulation Area
a, Roof Deck (Unvented)
R=20.0 1975.00 ft2
6. Conditioned floor area above grade Ift) 1975
b. N/A
R= ft'
Conditioned floor area below grade (ft� 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(180.0 sgft.) Description Area
a. Sup: Attic, Ret: AH, AH: AH
6 120
a; U-Factor: Dbl, U=0.65 118.50 ft2
SHGC: SHGC=0.25
b. U-Factor: Dbl, U=0.65 61.50 ft'
12. Cooling systems
kBlu/hr Efficiency
SHGC: SHGC=0.30
a. Central Unit
29.4 SEER:16.00
c. U-Factor: N/A ft'
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U=Factor: N/A ft'
a. Electric Strip Heat
27.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 3.133 ft.
Area Weighted Average SHGC: 0.267
14. Hot water systems
8. Floor Types (1975.0 scift.) Insulation Area
a. Electric
Cap: 50 gallons
EF: 0.950
a. Slab -On -Grade Edge Insulation R=0.0 7975.00 ft'
b. Conservation features
b. N/A R= ft'
None
c. N/A R= ft'
15. Credits
CF, Pslat
Glass/Floor Area: 0.091 Total Proposed Modified Loads: 55.61
PASS
Total Baseline Loads: 62.23
I hereby certify that the plans and specifications covered by
Review of the plans and
ST��
this calculation are in compliance with the Florida Energy
specifications covered by this
OFTtiE
�S' , = e , O
Code.
calculation indicates compliance
�•.•; °„ r0
with the Florida Energy Code.
nnr,,:. lariy;;�
PREPAR D BY'
Before construction is completed
v
DATE:
this building will be inspected for
compliance with Section 553.908
0
I hereby certify that this ' 0 r designed, is in compliance
Florida Statutes.
!,),
with the Florida En C
COp we
OWNER/AGE T:
BUILDING OFFICIAL:
DATE:
DATE:
• - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
REVIEWED FOR
CODE COMPLIANCE
Sio LUCIE COUNTY
4/2/2019 10:47 AM EnergyGauge® USA Section R405.4.1 Compliant Software BOCC Page 1 of 6
'FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: Ditullio Residence
Bedrooms: 3
Address Type:
Street Address
Building Type: User
Conditioned Area: 1975
Lot #
Owner Name: Ditullio Residence
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: No
PlalBook:
Builder Name:
Rotate Angle: 0
Street:
Lot 17 & 19 Gopher Rid
Permit Office: St. Lucie County
Cross Ventilation: No
County:
St. Lucie
Jurisdiction: St. Lucie County
Whole House Fan: No
City, State,
Zip:
Fort Pierce ,
Family Type: Single-family
FL, 34982
New/E)dsling: New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO BEACH MUNI 39
90
70
75
299
62
Low
BLOCKS
Number Name
Area
Volume
1 Entire House
1975
18565
SPACES
Number Name
Area
Volume Kitchen Occupants
Bedrooms
Infil ID
Finished Cooled
Heated
1 Laundry
87
817.8 No
1
1
Yes
Yes
Yes
2 Master Bath
139
1306.6 No
1
1
No
Yes
Yes
3 AH
12
112.8 No
0
1
No
Yes
Yes
4 WIC
54
507.6 No
0
1
Yes
Yes
Yes
5 Hall
24
225.6 No
0
1
No
Yes
Yes
6 Master Bedroom
213
2002.2 No
2
1
1
Yes
Yes
Yes
7 Dining
216
2030.4 No
2
1
Yes
Yes
Yes
8 Kitchen
238
2237.2 Yes
2
1
Yes
Yes
Yes
9 Bedroom 3
198
1861.2 No
2
1
1
Yes
Yes
Yes
10 Bathroom
81
761.4 No
0
1
Yes
Yes
Yes
11 Bedroom 2
195
1833 No
2
1
1
Yes
Yes
Yes
12 Hall
36
338.4 No
0
1
No
Yes
Yes
13 Pantry
14
131.6 No
0
1
No
Yes
Yes
14 Great Room
468
4399.2 No
2
1
Yes
Yes
Yes
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpel
1 Slab -On -Grade Edge Insulatio
Laundry 15 ft 0
87 ft'
_
1 0
0
2 Slab -On -Grade Edge Insulatio
Master Bath 1 ft 0
139 ft'
_
1 0
0
3 Slab -On -Grade Edge Insulatio
AH 1 it 0
12 ft-
_
1 0
0
4 Slab -On -Grade Edge Insulatio
WIC 5 ft 0
54 ft'
—
1 0
0
4/212019 10:47 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 2 of 6
'FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
5 Slab -On -Grade Edge Insulatio
Hall 1 1 ft
0
24 ft2
_
1
0
0
' 6 Slab -On -Grade Edge Insulatio
Master Bedroom 28 ft
0
213 ft2
_
1
0
0
7 Slab -On -Grade Edge Insulatio
Dining 12 ft
0
216 ft2
—
1
0
0
8 Slab -On -Grade Edge Insulatio
Kitchen 12 ft
0
238 ft2
1
0
0
9 Slab -On -Grade Edge Insulatio
Bedroom 3 30 ft
0
198 ft2
_
1
0
0
10SIab-On-Grade Edge Insulatio
Bathroom 9 ft
0
81 ft2
—
1
0
0
11SIab-On-Grade Edge Insulatio
Bedroom 2 28 ft
0
195 ft'
—
1
0
0
12SIab-On-Grade Edge Insulatio
Hall 1 ft
0
36 112
—
1
0
0
13SIab-On-Grade Edge Insulatio
Pantry 1 ft
0
14 ft2
1
0
0
14SIab-On-Grade Edge Insulatio
Great Room 24 ft
0
468 ft2
—
1
0
0
ROOF
/
Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
V
# Type Materials Area
Area
Color
Absor. Tested
Tested
Insul.
(deg)
1 Hip
Metal 2139 ft2
0 ft2
Light
0.6
No
0.9
No
20
22.6
ATTIC
/
V
# Type
Ventilation Vent Ratio (1
in)
Area
RBS
IRCC
1 Full attic
Unvented
0
1975 ft2
N
N
CEILING
# Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1 Under Attic (Unvented)
laundry
20
Blown
87 ft2
0.1
Wood
2 Under Attic (Unvented)
Master Bath
20
Blown
139 ft2
0.1
Wood
3 Under Attic (Unvented)
AH
20
Blown
12 ft2
0.1
Wood
4 Under Attic (Unvented)
WIC
20
Blown
54 ft2
0.1
Wood
5 Under Attic (Unvented)
Hall
20
Blown
_24 ft2
0.1
Wood
_
6 Under Attic (Unvented)
Master Bedroom
20
Blown
213 ft2
0.1
Wood
_
7 Under Attic (Unvented)
Dining
20
Blown
216 ft2
0.1
Wood
8 Under Attic (Unvented)
Kitchen
20
Blown
238 ft2
0.1
Wood
9 Under Attic (Unvented)
Bedroom 3
20
Blown
198 ft2
0.1
Wood
_
10 Under Attic (Unvented)
Bathroom
20
Blown
81 ft2
0.1
Wood
11 Under Attic (Unvented)
Bedroom 2
20
Blown
195 ft2
0.1
Wood
12 Under Attic (Unvented)
Hall 2
20
Blown
36 ft2
0.1
Wood
13 Under Attic (Unvented)
Pantry
20
Blown
14 ft2
0.1
Wood
14 Under Attic (Unvented)
Great Room
20
Blown
468 ft2
0.1
Wood
412/2019 10:47 AM EnergyGaugeO USA Section R405A.1 Compliant Software Page 3 of 6
3'
o
o
0
o
o
0
o
o
o
o
o
o
0
0
0
0
o
o
v
m
C
o
C
0
C
0
C
0
C
0
C
0
C
0
C
0
C
0
C
o
C
a
C
o
m
O
N
V
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
O
O
O
¢
N
N
y
�O
t0
t0
t0
t0
t0
N
N
t0
N
tD
t0
�O
t0
O
O
O
o
d
d
c
0
a
t
t
m
c
0
c
m
c
m
c
0
c
m
c
m
c
m
c
m
c
m
c
w
c
N
N
N
m
O
O
Z
O
Z
O
Z
O
Z
O
Z
O
Z
O
Z
O
Z
O
Z
O
Z
O
Z
E
O
O
O
O
O
O
O
O
O
O
O
O
O
O
N
N
N
`
C
15
�0
O
O
O
LL
N
—
LL
C_
C
L
C
0
C
C
C
C
C
C
C
C
C
C
C
w 1
L
0
v
V
v
v
v
v
v
v
v
v
v
N
a
L
-
r
-
-
r
-
tC
—
—
—
—
—
C'
a
C
C
C
g
C
C
a
C
C
C
C
LL
M
j L
C
C
C
C
C
C
C
C
C
C
C
v
N
v
M
0
0
eD
M
M
•t
O
U O.
C
G
C
O
G
O
G
O
O
O
G
?
a
W
❑
C
C
C
C
C
C
C
C
C
r
C
N�<
�
�
�
.-
�
�
O
W
��
N
N
T
M
N
tp
N
N
N
N
N
N
N
f0
t0
W
M
0
C
C
C
C
am!
C
Z.
W
Q
f0
N
_
C
0
m
rn
m
rn
m
m
rn
m
m
rn
rn
rn
m
rn
rn
rn
m
a
v
w
E
z
z
z
z
z
z
z
z
z
z
z
0
0
0
0
0
0
0
0
0
0
0
0
0
0
c
0
—
r
o
y
Z
O
g
yLL`
N
N
N
N
N
N
N
J
Q 0
o
c
o
0
0
0
0
0
0
o
c
O
y
Q
Q
Oc
O
Z
0
N
V'
V
V
V
V
V
't
Y
V
'd'
<
V
d'
V"
•'
�'L"
N
t0
N
N
N
N
f0
N
N
N
N
N
U
y
LL
O
O
O
C
Ci
o
0
0
0
0
0
a
D
M
M
M
N
N
E
❑
0
Z
Z
d
d
M
c
E
E
E
o
E
E
o
Z'
m
E
0
E
U
d
==
3
w
`-
O
O
C
O
U
y
y
N
y
y
N
y
N
N
N
y
N
J
J
N
N❑
Y
y
y
d
y
d
J
J
9
9
J
5
S
S
J
y
in
im
y
22
C
C
C
MC
bCl
C
C
C
C
C
C
C
C
C
U'
N
Y
•C
W
W
W
W
W
W
W
W
W
W
N
N
N
N
N
N
N
N
N
N
N
n
a
a
n
a
D
a
a
a
a
a
O
O
V
V
U
U
V
V
V
V
V
V
a
a
a
6
O
O
O
O
O
O
O
0
O
O
O
O
O
0
O
O
0
O
O
O
O
O
O
O
O
O
O
O
T
q❑❑❑❑❑❑❑❑❑❑❑
m
m
m
m
m
m
m
m
m
m
m
m
m
m
3
9
3
a
LL
w
w
w
w
w
w
w
w
w
w
w
°
oo
o
0
0
0
0
0
0
0
0
0
0
V
O
O
V
V
V
U
V
U
V
V
V
O
O
E
E
E
J
J
J
J
J
J
J
J
J
J
J
C
C
C
C
C
C
C
C
C
C
C
C
C
C
y
y
N
N
O
N
N
N
N
N
W
N
W
N
N
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
y
c
c
c
c
c
c
c
c
c
c
c
c
c
m
m
m
O
3❑
v
N
N
n
m
,N_,
¢
w
urS
u
urS
urS
urS
urS
urS
uT3
urS
c�
z
m
3
z
z
z
w
w
U)
w
w
O
z
w
3
m
3
z
z
z
w
N
w
w
0(o
z
z
z
#
ik
N
M
v
N
�0
n
w
m
0
NI
MI
a
NI
NI
nl
OI
OI
OI
�I
�I
�I
�I
�I
NI
'I
N
v
Ot
a
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
GARAGE
' #
Floor Area Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
441 ft'
441 ft'
21ft 9.4ft 11
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse
Proposed ACH(50)
.000418
2165.9 118.91 223.62 .318 7
HEATING SYSTEM
#
System Type
Subtype
Efficiency Capacity Block
Ducts
1
Electric Strip Heat/
None
COP:1 27 kBlu/hr 1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1
Central Unit/
Split
SEER: 16 29.4 kBtuthr cfm 0.7 1
sys#1
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt Conservation
1
Electric None
Garage
0.95 50 gal 60.9 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cart # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None
None
W
DUCTS
V #
Supply—
Location R-Value Area
—Return Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT ON RLF
HVAC#
Heat Cool
1
Attic 6 120 ft'
AH
10 ft' Default Leakage AH (Default) (Default)
1 1
4/2/2019 10:47 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 5 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
TEMPERATURES
ProgramablThermostat: Y
Calling Fans:Coolin
�re Jan
Venting Jan
Feb
rr�
fr[` ]J
[` ]J
rl
t[r` ]J
fr[,
Oct M
rIE�]1
NOV
Nov
H Dec
. [ ]
lxl Mar
lxl
Apr
[
May
lXl Jun
Jul
lXl Aug
lXl Sep
lxl Oct
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Healing (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 lbs/sq.ft.
0 ft2
0 ft
0.3
Laundry
Default(8 lbs/sq.ft.
ft2
ft
0.3
Master Bath
Default(8 lbs/sq.ft.
ft2
ft
0.3
AH
Default(8 lbs/sq.ft.
ft2
ft
0.3
WIC
Default(8 lbs/sq.ft.
ft2
ft
0.3
Hall
Default(8 lbs/sq.ft.
ft2
ft
0.3
Master Bedroom
Default(8 lbs/sq.ft.
ft2
ft
0.3
Dining
Default(8 lbs/sq.ft.
ft2
ft
0.3
Kitchen
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bedroom 3
Default(8 lbs/sq.ft.
ft2
ft
0.3
Bathroom
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bedroom 2
Default(8 lbs/sq.@.
ft2
ft
0.3
Hall
Default(8 lbs/sq.ft.
ft2
ft
0.3
Pantry
Default(8 Ibs/s .ft.
ft2
ft
0.3
Great Room
Name:
Rating Compant:
... IL1llilllii)",,, : -
r
4/2/2019 10:47 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 6 of 6
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Ditullio Residence Builder Name:
Street: Lot 17 & 19 Gopher Ridge Road Permit Office: St. Lucie County
City, State, Zip: Fort Pierce, FL, 34982 Permit Number:
Y
Owner. Dilullio Residence Jurisdiction: St. Lucie County
w
Design Location: FL, Fort Pierce
c=i
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in an dropped ed ceiling/soffit
Y
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
as.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind ninino and wirina.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire sprinkler cover plates and walls or cellinat;
a. In aaamon, inspection of log walls snail be In accordance with me provisions of IGG-400.
412/2019 10:47 AM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 89
The lower the Energy Performance Index, the more efficient the home.
1. New home of, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location Attic/AH
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
3
13. Cooling system: Capacity
29.4
a) Split system SEER
16.0
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1975
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.650
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.267
14. Heating system: Capacity
27.0
c) Area
7c.
180.0
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
1.0
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
OAS
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF_
2. Masonry (Insulation R-value)
10A2.
4.1
0 Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131.
11.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level a) Ceiling fans Yes
a) Under attic 11a. 20.0 b) Cross ventilation No
b) Single assembly 11b. c) Whole house fan No
c) Knee walls/skylight walls 11c. d) Multizone cooling credit
d) Radiant barrier installed 11d. No e) Multizone heating credit
f) Programmable thermostat Yes
'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be' stalled (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be cc ete e c installed code compliant features. // c
Builder Signature: Date:/ l /
Address of New Home: Lot 17 & 19 Gopher Ridge Road City/FL Zip: Fort Pierce, FL 34982
4/2/2019 10:47:48 AM EnergyGaugeO USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
o
�- wrightsoftProject Summary Date:
Entire House By:
Quick Calcs, Inc.
317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772466-6799 Email: quickcalcs®aol.cem
Project11 • •
For: Ditullio Residence
Lot 17 & 19 Gopher Ridge Road, Fort Pierce, FL 34982
Notes:
Design
Information
Weather:
Fort Pierce, FL, US
Winter Design Conditions
Summer Design Conditions
Outside db 42 OF
Outside db
90
OF
Inside db 70 OF
Inside db
75
OF
Design TO 28 OF
Design TO
15
OF
Daily range
M
Relative humidity
50
%
Moisture difference
61
gr/Ib
Heating Summary
Structure
20694
Btuh
Duds
3616
Btuh
Central vent (0 cfm)
0
Btuh
(none)
Humidification
0
Btuh
Piping
0
Btuh
Equipment load
24310
Btuh
Infiltration
Method
Construction quality
Fireplaces
Simplified
Average
0
Heat
C1 975
Area (ft2)
1975
Volume (fta)
18565
18565
Airchanges/hour
0.38
0.20
Equiv. AVF (cfm)
118
62
Heating Equipment Summary
Make
Trade
Model
AHRI ref
Efficiency
Heating input
Heating output
Temperature rise
Actual air flow
Air flow factor
Static pressure
Space thermostat
100 EFF
7.0 kW
23921 Btuh
22 OF
980 din
0.040 cfm/Btuh
0.50 in H2O
Sensible Cooling Equipment Load Sizing
Structure
17931
Btuh
Duds
2456
Btuh
Central vent (0 cfm)
0
Btuh
(none)
Blower
0
Btuh
Use manufacturer's data
n
Rate/swing multiplier
0.95
Equipment sensible load
19368
Btuh
Latent Cooling Equipment Load Sizing
Structure
5385
Btuh
Ducts
1818
Btuh
Central vent (0 cfm)
0
Btuh
(none)
Equipment latent load
7203
Btuh
Equipment Total Load (Sen+Lat)
26571
Btuh
Req. total capacity at 0.70 SHR
2.3
ton
Cooling Equipment
Summary
Make Trane
Trade TRANE
Cond 4TTR4031L1
Coil TEM6AOC36H31++TDR
AHRI ref 7567544
Efficiency
13.0 EER, 16 SEER
Sensible cooling
20580
Btuh
Latent cooling
8820
Btuh
Total cooling
29400
Btuh
Actual air flow
980
arm
Air flow factor
0.048
cfm/Btuh
Static pressure
0.50
in H2O
Load sensible heat ratio
0.74
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wrigAfrsoft 2019-Apr-0211:21:28
ACC -----.•-.-. Right-Suile® universal 201919.0.01 RSU08101 Paget
...ocuments\Wrightsoft WACUJitullio Resioence.rup Calc=MJ8 Front Door faces: S
wrightsoft Right-M Worksheet Job:
Entire House Data:
Quick Calcs, Inc. By.
317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772466.6799 Email: quickcalcs@aol.com
1
2
3
4
5
Room name
Exposed wall
Room height
Room dimensions
Room area
Entire House
163.0 ft
9.4 ft
1975.0 ft-
Laundry
15.0 ft
9.4 R heaUceol
1.0 x 87.0 ft
87.0 ft-
Ty
Construction
number
U-value
(tit_ alU2 OF
Or
I HTM
(Btuh/ft)
I Area (ft')
or perimeter (ft)
I Load
(Btuh)
I Area (it')
or perimeter (ft)
I Load
(Btuh)
Heat
Cool
Gross
I N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
fi
11
UUUrrr111
13A-0oce
4A5-20m
4A5-2om
4A5-2om
4A5-2cmd
0.143
0.770
0.770
0,770
_0.770
0.143
0.770
_ 0.770
n
n
n
n
_n_
a
a
4.00
21.56
21.56
21.56
_21.56
4.00
21.56
2156
2.19
19.31
19.31
19.31
_19.31
2.19
43.77
45.10
479
5
9
15
__61
385
9
15
390
0
0
0
0
361
2
2
1560
97
19
323
_1319
1447
194
323
853
87
1
290
122
5
0
0
0
118
0
0
0
471
97
0
0
'258
87
0
0
__0
41
0
0
V)1
I�-GG
13A-4ocs
4A5-20m
4A5-20m
_1182
791
394
677
19
0
0
__0
19
0
0
__ .0
75
0
0
--13A4ocs
4A5-20m
4A5-2om
11D0
13AAocs
W-20m
22A-tpl,
0.143
0.770
0.770
__a
s
s
s
_s_
w
_
=_
4.00
21.56
21.56
-10.92,
4.00
21.56
�7.50
27.69
_
2.19
19.31
19.31
_10.34
2.19
�45.10
_7.37
_0.00
_
479
3
48
2020
188
_ 15
_79757975
1975
408
6
96
173
2
163
1634
65
1035
-223
693
323
-3131
M 4514
893
58
927
.�211
379
_677
�_2702
_ 0
'---0--
0
0
0
0
0
- 0
--0
0
'0
0
_
0
0
0
__0
0
0
_719
0
.
Y)I
_G
_0.390
0.143
0770
�0.408
_,0.989
_,.0
0
0
0
_ 0
7
0
0
^__738
.0_..18X79-0mE
-87
_87
15
415
61
c) AED excursion
0
-22
Envelope loss/gain
17078
10291
1197
482
12
a) Imijuation
b) Room ventilation
3618
0
1020
0
333
0
94
0
13
Internal gains: Occupants@ 230
Appliances/other
14
3220
3400
1
230
Sao
Subtotal lines 6 to 13)
20694
17931
1530
1306
141ess
exlemal load
ess Uansis
edistribution
ubtotal
uct foods
17%
14%
0
0
0
20694
3616
0
0
0
77931
2456
17%
14%
0
0
0
1530
267
0
0
0
1308
179
AiTotar requiredl(=) I
I
I
249310 80I
2038071
I
I
1772I
1481I
Calculations approved by ACCA to meet all reouirements of Manual J Sth Ed
1-rl&- !n�.�9ti=a,�>K,' 2019Apr-021121:28
c& Right -Suite® Universal 201919.0.01 RSU08101 Pages
...ocumentsWightsoR HYACIDilullio Residence.mp Calc=MJ8 Front Door races: S
wrightsoftRight-M Worksheet Job:
Entire House Date:
Quick Calcs, Inc. By:
317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-46M799 Email: quickcelcs@aol.cum
1
2
3
4
5
Room name
Exposed well
Room height
Room dimensions
Room area
Master Bath
a ft
9.4 ft heat/cool
1.0 x 139.0 It
139.0 fP
AH
0 It
9.4 ft heat/cool
4.0 x 3.0 ft
12.0 ft-
Ty
Construction
number
U-value
(Btuh/ft' Fj
Or
I HTM
(Bt uh/ft�
I Area (ft°)
or perimeter (R)
I Load
(Btuh)
I Area (it-)
or perimeter (ft)
I Load
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
I WP/S
Heat
Cool
r6
8
71
4)/
II--�'
13A-2onn
4A5-tom
4A5-2om
4A5-2om
4A&2omd
0.770
0.770
0.770
0.770
_0.770
n
n
n
n
-n_
a
a
e
4.56
21.56
2156
21.56
-21.56
4.00
2156
21.5645.10
19.31
9.31
19.31
19.31
-19.31
2.19
43.77
0
0
0
0
--0
0
0
0
0
0
0
0
__0
0
0
0
0
0
0
0
0
0
0
0
.__.__0
0
0
0
0
0
0
0
-_0
0
0
0
0
0
0
0
__0
0
0
0
0
0
0
0
__-0
0
0
0
0
0
0
0
�.,._..0
0
0
0
13A-4oce
4A5-20m
4A5-20m
0.143
0.770
0.770
�0
0
0
0
wI�'''`,'
I-
���
_ _
�-
13A�4=
4A5-tom
4A5-2om
11D0 _
13A-4ocs
4AS-2om_
_16X19-0md_ '
22A;lul__-__-_
0.143
0.770
0.770
-0.390
0.143
0.770
-0.408
___p.989
_
s
s
a
_s_
w
_w
4AD
21.56
21.56
-._10.92
4AD
2156
_1.54,
_ 2.19'�'-U
-'-2.19
19.31
19.31
_10.34
2.19
_45_10
1.37,
- 0
0
_-0
0
0
-.139
_
0'
0
0
__0
0
0
0
0
0
0
0
_0
_220
-0
0
0
_._0
0
0
-0
0
0
__0
0
0
12
0
0
0
__0
0
0
._72
0
0
0
_
0
0
0
0
0
lql
=o
.C_
F
-0
0
_ _ 0.
79
_739
_ 190
._,.___16
0
27.69
0.00
139
0
0
0
72
--0
0
61
c) AED excursion
_7
0
Envelope loss/gain
220
183
19
16
12
a) Infiltration
b) Room ventilation
0
0
0
0
0
0
0
0
13
Internal gains: Occupants (aj 230
Appliances/other
1
230
0
ti
0
0
Subtotal (lines 6 to 13)
2201
413
1
1 19
16
14
15
Less external load
Less transfer
Redistdbution
Subtotal
Duct loads
17%
14%
0
0
13
234
41
0
0
11
424
58
17%
14%
0
0
-19
0
0
0
0
-18
0
0
oad
Airarequired(cfm) I
I
I
�il
4I
I
I
gl
g
Calculations approved by ACCA to meet all reauirements of Manual J Sth Ed
w�f9!=cam o� 2019-Apr-0211:2
128
Right-Suite® universal 201919.0.01 RSU08101 Page
...ucumentslVJrighteoft HVACIDitullio Residence.rup Cale =MJ8 Front Door faces: S
wrightsofr Right-J® Worksheet Job:
Entire House pate:
Quick Calcs, Inc. By.
317 SL Lucie Lane, Fort Pierce, FL 34946 Phone: 772466-6799 Email: quickcalcs@aol.com
1
2
3
4
5
Room name
Exposed wall
Room height
Room dimensions
Room area
WIC
5.0 ft
9.4 ft heaticool
6.0 x 9.0 ft
54.0 ft-
Hall
0 ft
9.4 ft heaVcool
4.0 x 6.0 ft
24.0 ft2
Ty
Construction
number
U-value
(Bluhlfl"F
Or
HTM
(Bluwft2)
Area (1t2)
or perimeter (ft)
Load
I (Btuh)
Area (W)
I or perimeter (ft)
Load
I (Btuh)
Heat
Cool
Gross
WP/S
j Heal
Cool
Gross
WP/S
Heat
Cool
I
6
11
13XZM
4A5.2om
4A5-tom
4A5-2om
AA5-2omd
13A-40cs
4A5-2om
4A5-2om
0.143
0.770
0.770
0:770
_0.770
0.143
0.770
0.770
_
n
n
- n
n
4.00
21.56
21.56
21.56
21.56.
2.19
19.31
19.31
19.31
___
0
D
0
0
___
0
0
0
0
� 0
0
0
0
0
0
0
0
0
__
0
0
0
0
__
0'
0
0
0
0
0
0
0
_ _
0
0
0
0
_
VI!
�L{f'
-n_
a
a
a
4.00
21.56
21.56
_19.31
2.19
43.77
45.10
-0
0
0
0
-0
0
0
0
-0
0
0
0
0
0
0
-0
0
0
0
___0
0
0
0
_�._._0
0
0
0
_____0
0
0
-
13A-0acs
4A5-2om
4A5.2om
.1.1D0
13A4ocs
4A5.2om ______
.16X79-0m1
22AjpL _
0.143
0.770
0.770
5
s
s
_s,_
w
_w_
=
4.00
21.56
21.56
_,10.92
4.00
21.5E
_ .59.
.i
2.19
19.31
19.31
-10.34
2.19
45.10
�1.37
0
0
0
0
0
0
0
0
0
0
0
0
-0
0
0
-0
0
0
0
0-
0
__a
0
0
0
_.____0
0
0
:_33
.0
F_ _
__0.390
0.143
�0.770
�0.408
__.,._0
47
0
54
__0
47
0
.__0
188
0
^_e6
__._0
103
0
_74'�24
.__._._0
0
0
__00.
0
0
�24
0
0
r 38
._54
0.989
_-
27.69
0.00
___54
_ 5
138
0
r24
61
c) AED excursion
_3
_1
Envelope loWgain
412
173
38
32
12
a) Infiltration
b) Room ventilation
ill
0
31
0
0
0
0
0
13
Internal gains: Occupants@ 230
AppliancestoNer
0
0
0
0
0
0
Subtotal (lines 6 to 13)
6231
2051
381
32
14
15
Less external load
Less transfer
Redistribution
Subtotal
Duct loads
17%
14%
0
0
0
523
91
0
0
0
205
28
17%
14%
0
0
-38
0
0
0
0
-32
0
0
Air rel quired (cfm) I
I
I
6216
5I
211I
I
I 0I
0
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed
-PW wrigtigofY 201OMi, 0211:21:28
Right -Suite® universal 201919.0.01 RSU08101 Page
...omments\Wdghtsofl HVACIDitullio Residence.mp Cale=MJ8 Frenl Doorfaces: 5
+wrightsoft• Right-J® Worksheet Job:
Entire House Date:
Quick Calcs, Inc. By:
317 St. Lude Lane, Fort Pierce, FL 34946 Phone: 772 .66-6799 Email: quickcelcs@aol.com
1
2
3
4
5
Room name
F,xposed wall
Room height
Room dimensions
Room area
Master Bedroom
28.0 ft
9.4 ft heat/ocol
1.0 x 213.0 ft
213.0 ft
Dining
12.0 ft
9.4 It heat/cool
72.0 x 18.0 It
216.0 fP
Ty
Construction
number
U-value
(Btuhlfl'-'Fy
Or
HTM
I (zh fP3
Area (ft')
I or perimeter (H)
Load
I (Btuh)
Area (fill
I or perimeter (ft)
Load
I (Btuh)
Heat
Coal
Gross
WP/S
Heat
Cool
Gross
WNS
Heal
Cool
fT
I
6
71
___T__
13A-4ors-
4A5-2om
4A5-2om
4A5-tom
4A5-2omd- -
13A-4ocs
4A5-2om
4A5-2om
0.143
0.770
0.770
0.770
_,-__0.770
0.143
0.770
0.770
n
n
n
n
_n_
a
a
a
4.00
21.56
21.56
21.56
_21.56
4.00
21.56
21.56
2
19.31
19.31
19.31
_19.31
2.19
43.77
45.10
_.19 � 0
0
0
0
0
0
0
0
---0
0
0
0
0
0
0
0
0
113
0
0
0
__61
0
0
0
52
0.
0
0
_____0
0
0
0
207
0
0
0
-1319
0
0
0
� 173
0
0
0
__,_1182
0
0
0
_
-0
0
0
0
-0
0
0
0
--0
0
0
0
0
0
0
F--G
�p
A-
134crs.
4A5-20m
4A5-2om
11D0
13A-4ace
4A5.2am
.16X79-0m_ d
22A-Iol-„__
0.143
0.770
0.770
s
s
s
"s_
w
w
=
4.00
21.56
21.56
--10.92
4.00
21.56.
-1.59.
27.69
2.19
19.31
19.31
122
0
12
110
0
12
441
0
259
241
0
232
0
0
0
0
0
0
- 0
0
0
-- 0
0
0
___0
0
0
-296
0
t-G
.C_
F
_-0.390
0.143
-0.T70
-0.408
0.989
-10.34
2.19
45.10
..4 ,1.37
0.00
___0
141
_15
213
__213
--0-0--0
126
1
505
323677.
_338
_775
276
_--291
0
____.0
0
_ 0
_._216
216
-0
0
0
-0
0
0
_,342
-----,P32
_
_213
28
_ 216
12
61
0AED excursion
254
-36
Envelope losstgain
2641
1970
2201
7554
12
a) Infiltration
b) Room ventilation
622
0
175
01
266
0
75
0
13
Internal gains: Occupants@ 230
Applianceslother
2
460
0
2
460
0
Subtotal (lines 6 to 13)
32621
2606
1
2467
2090
[Less
14
external load
Less transfer
Redistribution
Subtotal
Dud bails
17%
14%
0
0
24
3286
574
0
0
20
2626
360
17%
14%
0
0
6
2473
432
0
0
5
2094
287
oad
TotaAir requiredmoml(cfm) I
I
I
3158I
2144I
I
I 295 1017I
21g4
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
'e'I'r' w�!191ti oR' 2019-Apr.0211:21:28
Right eside®Universa1=MJ8 Front oorfac01 Page4
...ocumenls\WdghtsoH HVAC1Ditu1lio Residence.mp Cale =MJB Front Doorfaces: S
F#f wrightsoft° Right-M Worksheet Job:
Entire House Date:
Quick Calcs, Inc. By.
317 St. Lude Lane. Fan Pierce, FL 34946 Phone: 772466-6799 Email: quickralcs@aol.com
11
2
3
4
5
Room name
F°xposed wall
Room height
Room dimensions
Room area
Kitchen
12.0 ft
9A It heat/cool
1.0 x 238.0 ft
238.0 ft-
Bedroom
30.0 ft
9.4 ft heallcool
1.0 x 198.0 ft
198.0 W
Ty
Construction
number
U-value
I(Btuh/itz°F�
IIF
Or
I HTM
(Btuh/fl)
I Area (W)
or perimeter (ft)
I Load
(Btuh)
Area (ft.)
or perimeter (ft)
I Load
(Stun)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
WP/S
Heat
Cool
fi
11
y%
Ilflt---rrG
_
13A-flocs
4A5-20m
4AS2am
4AS2om
4A5-20md
13A.4ocs
4A5-2om
4A5-2om
0.770
0.770
0.770
0.770
_0.770
0.143
0.770
0.770
�n
n
n
n
-n-.
a
a
a
4.56
21.56
21.56
21.56
_21.56
4.00
21.56
21.56
9.31
19.31
19.31
19.31
__19,31
2.19
43.77
45.10
170
0
9
0
--0
100
0
0
0
_-_0
410
0
184
0
0
220
0
174
0
_-_0
132
0
0
15
-0
777
0
0
0
.-0
-487
0
0
323
-0
255
0
0
290
--..0
308
0
0
0
0
0
0
0
0
0
0
0_
0
0
0
141
0
0
141
0
0
565
0
0
_
13A.1ocs.
4A5-20m
4A5-2oin
1,1D0
0.143
0.770
0.770
s
s
s
-ate
w
_w
;._
4.00
21.56
21.55
-10.92
4.00
21.56
-1.59
27.69.
-2.19
19.31
19.31
0
0
0
0
0
0
0
^- 0
0
0
0
0
0
0
9
0
0
9
0
0
-- 38
0
0
21
0
0
___-_0
0
0
_v_.27.1
0
Vrf
13A-0ocs
4AS2onn
-16X79:Omd___
22A-tpl____
__0.390
0.143
0.770
-0.408
_0989
,_10.34
2.19
_45.10
_7.37.
0.00
-0
0
0_
0
0
0
0
� 377
332
_0
0
0_
�0
0
0
e0
0
0
_,_.0
0
0
C_
F
_._238.__238
238
12
.�326
0
98198
198
30
_
___314
._831
61
c)AED excursion
-55
-30
Envelope loss/gain
1319
672
2537
1115
12
a) Infiltration
b) Room ventilation
266
0
75
0
1
666
1 0
188
0
13
Internal gains: Occupants @ 230
Appliances/other
2
460
2110
2
460
0
Subtotal (lines 6 to 13)
1
15861
32071
1
1 3203
1762
14
15
Less extemal load
Less transfer
Redistribution
Subtotal
Dud leads
17%
14%
0
0
4
1590
278
0
0
4
3211
440
17%
14%
0
0
9
3212
561
0
0
7
1770
242
AIr requ'ued (Cm) I
I
I
1875I
3175I
I
I
3152I
2097I
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed
�}► wrlgto�o.T 2019.Apr.0211:21:28
Right -Suite® Universal 201919.0.01 RSU08101 Page
...ocumenlslWrightsoft HVACIDilullio Residence.mp Cate=M.18 Front Door faces: S
wrightsoft• Right-J® Worksheet Job:
Entire House Date:
Quick Calcs, Inc. By:
317 St Lucie Lane, Fort Pierce, FL 34946 Phone: 772466-6799 Email: quickcalcs@aol.com
1
2
3
4
5
Room name
Exposed wall
Room height
Room dimensions
Room area
Bathroom
9.0 ft
9.4 ft heat/cool
9.0 x 9.0 ft
81.0 ft
Bedroom 2
28.0 ft
9.4 ft heat/cool
13.0 x 15.0 It
195.0 ft-
Ty
Construction
number
U-value
(Btuh/ft"FI
IOr
H7M
I (BtuNft�
Area (ft')
I or perimeter (ft)
Load
I (etuh)
Area (ft')
I or perimeter (ft)
Load
I (BNh)
Heat
Cool
Gross
I NIP/S
I Heat
I Cool
Gross
I NIP/S
Heat
Cool
1
fi
11
13A-40ds
4A5-2om
4AS-20m
4A5-2om
4A5-2omd_,__.
13A-0ocs
4A5-tom
4A5-20m
0.143
0.770
0.770
0.770
__-0.770
0.143
0.770
0.770
n
n
n
n
-n_
a
a
e
4.00
21.56
21.56
21.56
_.21.56
4.00
21.56
21.56
2
19.31
19.31
19.31
_19.31
2.19
43.77
45.10
�� 0
0
0
0
--0-0
85
9
0
0
0
0
0
76
1
0
0
0
0
0
__
0
0
0
0
0
_
0
0
0
0
0
0
0
0
-0
126
0
1
0
0
0
0
--.__0
505
0
323
v'.19 0
0
0
0
._
W
tG
._0
303
194
0
165
394
0
-0
141
0
15
_0
276
0
677
13A-4oes
4A5.2om
4AS2om
'.11DO
13A-40cs
4A5.2om
.16mg:Omtl
22A-Ipl__
0.743
0.770
0.770
,0.390
0.143
10.770
-0.400
0.989
_
s
s
s
_a_
w
w_
__-
4.00
21.56
21.56
_10.92
4.00
_21.58
_1.59.
27.69
2.19
19.31
19.31
_10.34
2.19
45.10
_7.37,
_0.00
�� 0
0
0
0
0
0
0
0
__
0
0
0
0
0
0
0
___ 0
0
0
___111
__ 122
0
12
-0
0
0
_195
170
0
12
0
__
441
0
259
__0
0
_ _0
�309
_ J 241
0
232
_._.0
0
0
. _267
Vy/
�G
C__
F _
-0-0
0
0
�81
^_81
0
,0
�728
0
0
-t95
_81
_ _ 9
249
---0
__795
-28
775
_ 0
61
c)AED excursion
-5
-39
Envelope loss/gain
874
665
i
i 2612
1653
12
a) Infiltrallon
b) Room ventilation
200
0
56
0
622
0
175
0
13
Internal gains: Occupants@ 230
Appliances/other
0
0
0
2
460
0
Subtotal (lines 6 to 13)
1074
721
1
3234
2288
14
15
Less external load
Less transfer
Redishibution
Subtotal
Dud loads
77%
14%
0
0
20
1094
181
0
0
17
738
701
17%
14%
0
0
9
3243
587
0
0
7
2296
314
TolaAir requf dI(cbn) I
I 7252I 81
840I
I
I 31096101
54I
2125
Calculations approved by ACCA to meet all requirements of Manual J 811h Ed.
w�Igls�s- 2019-Apr-0211:21:28
►S Right -Suite® Universal 201919.0.01 RSUD8101 Page
...ocuments\Wrightsoft HVACIDilullio Residence.rup Calc=We Front Doorfaces: S
I# wrightsoft Right-J® Worksheet Job:
Entire House Date:
Quick Calcs, Inc. By.
317 St Lude Lane, Fort Pierce, FL 34946 Phone: 772466-6799 Email: quickw1cs@aol.eom
1
2
3
4
5
Room name
Exposed wall
Room height
Room dimensions
Room area
Hall 2
O ft
9.4 H heat/caol
4.0 x 9.0 ft
36.0 n2
Pantry
O ft
9.4 If heat/cool
1.0 x 14.0 ft
14.0 H2
Ty
Construction
number
U-value
(Btuh/ft"F
Or
I Him
(Btuh/ft)
I Area (n2)
or perimeter (ft)
I Load
(Bluh)
I Area (ft.)
or perimeter (ft)
I Load
(Bluh)
Heal
I Cool
Gross
!P
Heat
I Cool
Gross
f4/P/S
Heal
Cool
�
6
11
._
W
I�-GG
ocs 13A-fl
4A5-20m
4A6-2om
4A5-20m
.4AS2omtl
0.143
0.770
0.770
0.770
0.770
0.143
0.770
0.770
n
n
n
n
_n_
a
a
e_
-
4.00
21.56
21.56
21.56
_21.56
4.00
21.56
21.55
- 2^
.19
19.31
19,31
19.31
-19.31
0
0
0
0
.__O
0
0
0
0
0
0
0
__O
�- 0
'0
0
0
0
0
0
0
0
__O
0
0
0
0
_O
0
0
0
0
__O
0
0
0
0
-0
-� 0
0
0
0
,.,___O
13A-flocs
4A5-2om
4A5.2om
2.19
43.77
45.10
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
13A4=
4A5-2om
4A5-2om
.11D0__
0.143
0.770
0.770
-0.390
s
s
3
,ems_
4.00
21.56
21.56
-10.92
2.19
19.31
19.31
,10.34
0
0
0
0
0^
0
0
_.___0
0
0
0
_._0
0
0
0
-0
0
0
0
-0
0~
0
0
,_ _O
0�
0
0
___p
_ �0
0
0
-0.
l�/
=G
13A-40=
4Ai2om
.i8X19:Omtl'�
22A:tpl
0.143
^,0.770
_0.408
____0.989
w
w_
_:_
-
4.00
21.56
_-1.59.
27.69.
2.19
45.10
-1.37
---0.00
0
i0
-36
36
0
0
0
0
__57
0
__ 0
_ _49
0
0
0
0
0
_=14
0
0
_e 0
__.-19
-C__.
__36
__14
_14
�0
-22
0
0
0
0
0
61
0AED excursion
1
-1
0
Envelope loss/gam
1 57
48
22
19
12
a) Infiltration
b) Room ventilation
0
0
0
0
0
0
0
0
13
internal gains: Occupants(P 230
Appliancestother
0
0
0
0
0
0
Subtotal Oines 6 to 13)
57
48
22
19
14
15
Less external load
Less transfer
Redismibution
Subtotal
Duct loads
17%
14%
-5
g
0
0
48
0
0
17%
14%
0
0
9
31
5
0
0
7
26
4
Alr rel gru�iretll (cfrn)
I
I I
0I
0I
I
I 31I
31
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
-�/- =11st soft 2019-Apr-02 11:21:28
Right -Suite® Universal 201919.0.01 RSU08101 Pagel
...ocumentsWfightsoft HVACIDitullio Residence.rup Gale =MJ8 Front Door faces: S
wrightsoft Right-M) Worksheet Job:
Entire House Date:
Quick Calcs, Inc. By:
317 St. Lucie Lane, Fort Pierce, FL 34M Phone: 772466-6799 Email: quickralcs@aol.cam
1
2
3
4
5
Room name
Exposed wall
Room height
Room dimensions
Room area
Great Room
24.0 It
9A ft heat/coot
1.0 x 468.0 ft
468.0 fP
Ty
Construction
number
U-value
(Btuh/fle T1
IOr
HTM
I (Bluh/ft-)
Area (fP)
I or perimeter (it)
Load
I (Stuh)
Area
I ofperimeter
Load
Heat
Cool
Gross
WP/S
Heat
Cool
Gross
WP/S
Heat
Co.]
-
-�T
6
11
1M
11111.-----'rG^G'=
�G
13A-flocs
4A5-tom
4A&2om
4A&2om
4A5-2amtl
13A-flocs
4A&2om
4A5.2om
-0.143
0.770
0.770
0.770
_0.770
0.143
0.770
0.770
n
n
n
n
_.n_
a
a
a
4.00
21.56
21.56
21.56
21.56
4.OD
21.56
2156
' 2.19
19.31
19.31
19.31
_19.31
2.19
43.77
45.10
0
0
0
0
__-0
0
0
0
0
0
0
0
0
-0--0
0
0
0
0
0
0
0
__-0
0
0
0
0
0
0
0
0
0
13A-40cc
4A5-2em
4A&2om
11D0
_
0.143
0.770
0.770
0390
s
s
a
�s_
4.00
21.56
21.56
_10.92
2.19
19.31
19.31
_10.34
�226
3
24
_20
178
3
24
_20
_
714
65
517
_223
390
58
463
--211
--
---
y!
C,.
F
13A-4ocs
4A&2om
l6X1Mad ___
22A;tol____
0.143
_0.770
___0.408
0.989
w
w _
_._
4.00
21.56
_.-1.59
_27.69
2.19
45.10
- 1.37
0.00
0
0
_ 468
_468
0
0
0
0
0
_468
_ _-24
742
_665
_0
_640
0
_
61
c)AED excursion
-55
Envelope loss/gain
1 2925
1707
12
a) Infiltration
b) Room ventilation
533
0
150
0
13
Internal gains: Occupants@ 230
Appliances/other
2
460
900
Subtotal (lines 6 to 13)
3458
3218
14
15
Less external load
Less transfer
Redistribution
Subtotal
Dud leads
17%
14%
0
0
21
3479
608
0
0
18
3235
443
Nrreq�o tll(chn)
I I
I
4085I
36��I
_ Calculations approved by ACCA to meet all reOuirements of Manual J 8th Ed.
- wrM1gtiesotiC' 2019Apr-0211:21:28
A RightSuilelf Universal 201919.0.01 RSUD8101 Page
...ocumentsXMghlsoft WACIDilullio Residence.mp Cole =M.18 Front Doorfaces: S
�- wrightsoft° Duct System Summary
Entire House
Quick Calcs, Inc.
317 St. Lucie Lane, Fort Pierre, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com
For: Ditullio Residence
Lot 17 & 19 Gopher Ridge Road, Fort Pierce, FL 34982
External static pressure
Pressurelosses
Available static pressure
Supply / return available pressure
Lowest friction rate
Actual air flow
Total effective length (TEL)
Heating
0.50
in H2O
0
in H2O
0.50
in H2O
0.250 / 0.250
in H2O
0.276
in/100ft
980
cfm
181
Job:
Date:
By:
Cooling
0.50
in H2O
0
in H2O
0.50
in H2O
0.250 / 0.250
in H2O
0.276
in/100ft
980
cfm
Name
Design
(Btuh)
Htg
(cfm)
Clg
(cfm)
Design
FR
Diam
(in)
H x W
(in)
Duct
Mad
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
Bathroom
h 1285
52
40
0.293
6.0
Ox0
VIFx
35.7
135.0
st3
Bedroom 2
h 3809
154
125
0.276
8.0
Ox 0
VIFX
46.3
135.0
st3
Bedroom
h 3773
152
97
0.288
8.0
Ox0
VIFx
38.8
135.0
st3
Dining
h 2905
117
114
0.359
7.0
Ox 0
VIFx
24.4
115.0
st1
Great Room
c 1839
82
88
0.351
7.0
Ox0
VIFx
27.3
115.0
all
Great Room -A
c 1839
82
88
0.351
7.0
Ox 0
VIFx
27.3
115.0
stl
Klchen
c 3650
75
175
0.367
8.0
Ox 0
VIFX
21.1
115.0
stl
Laundry
h 1797
72
71
0.388
6.0
Ox 0
VIFx
13.8
115.0
st2
Master Bath
c 483
11
23
0.410
5.0
Ox0
VIFx
7.1
115.0
st2
Master Bedroom
h 3860
156
144
0.379
8.0
Ox0
VIFX
16.8
115.0
st2
PWtry
c 36
1
1
0.290
4.0
Ox0
VIFX
37.2
135.0
st3
vmc
h 615
25
11
0.397
4.0
Ox0
VIFx
10.9
115.0
st2
Trunk
Htg
Clg
Design
Veloc
Diam
H x W
Duct
Name
Type
(drn)
(cfm)
FR
(fpm)
(in)
(in)
Material
Trunk
st3
Peak AVF
359
264
0.276
457
12.0
0 x 0
VinlFlx
st1
st1
Peak AVF
716
731
0.276
684
14.0
0 x 0
VinlFlx
st2
Peak AVF
264
249
0.379
484
10.0
0 x 0
VinlFlx
wrightsof - 2019.Apr.0211:21:29
�1- .,.... ....�o.,� Right -Suite® Universal 201919.0.01 RSUC8101 Page 1
M..I.F...oaments\WdghtsoH RVAC%Ditullie Residence.rup Cale =MJ6 Front Doorfacas:S
Return Branch Detail Table
Name
Grille
Size (in)
Htg
(cfm)
Clg
(cfm)
TEL
(ft)
Design
FIR(fpm)
Veloc
Diam
(in)
H x W
(in)
Stud/Joist
Opening (in)
Duct
Mall
Trunk
rb1
Ox0
980
980
0
0
0
0
Ox 0
VIFx
$ wri htsofV 2019-Apr-0211:21:29
.....�9 ....�...." Right -Suite® Universal 201919.0.01 RSU08101 Paget
�+� ...oamentslWrightsoft WAODitullio Residence.rup Calc= MJ8 Front Door faces: S