Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEr FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Ditullio Residence Builder Name: S{OMNED Street: Lot 17 & 19 Gopher Ridge Road Permit Office: St. Lucie County �1V State, Zip: Fort Pierce , FL, 34982 Permit Number: Omer:City, Omer: Ditullio Residence Jurisdiction: St. Lucie County v �^�e11Y®� Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1730.9 scift.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1534.90 ft' b. Frame - Wood, Adjacent R=11.0 196.00 ft' 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (1975.0 sgft.) Insulation Area a, Roof Deck (Unvented) R=20.0 1975.00 ft2 6. Conditioned floor area above grade Ift) 1975 b. N/A R= ft' Conditioned floor area below grade (ft� 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(180.0 sgft.) Description Area a. Sup: Attic, Ret: AH, AH: AH 6 120 a; U-Factor: Dbl, U=0.65 118.50 ft2 SHGC: SHGC=0.25 b. U-Factor: Dbl, U=0.65 61.50 ft' 12. Cooling systems kBlu/hr Efficiency SHGC: SHGC=0.30 a. Central Unit 29.4 SEER:16.00 c. U-Factor: N/A ft' SHGC: 13. Heating systems kBtu/hr Efficiency d. U=Factor: N/A ft' a. Electric Strip Heat 27.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 3.133 ft. Area Weighted Average SHGC: 0.267 14. Hot water systems 8. Floor Types (1975.0 scift.) Insulation Area a. Electric Cap: 50 gallons EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 7975.00 ft' b. Conservation features b. N/A R= ft' None c. N/A R= ft' 15. Credits CF, Pslat Glass/Floor Area: 0.091 Total Proposed Modified Loads: 55.61 PASS Total Baseline Loads: 62.23 I hereby certify that the plans and specifications covered by Review of the plans and ST�� this calculation are in compliance with the Florida Energy specifications covered by this OFTtiE �S' , = e , O Code. calculation indicates compliance �•.•; °„ r0 with the Florida Energy Code. nnr,,:. lariy;;� PREPAR D BY' Before construction is completed v DATE: this building will be inspected for compliance with Section 553.908 0 I hereby certify that this ' 0 r designed, is in compliance Florida Statutes. !,), with the Florida En C COp we OWNER/AGE T: BUILDING OFFICIAL: DATE: DATE: • - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). REVIEWED FOR CODE COMPLIANCE Sio LUCIE COUNTY 4/2/2019 10:47 AM EnergyGauge® USA Section R405.4.1 Compliant Software BOCC Page 1 of 6 'FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Ditullio Residence Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1975 Lot # Owner Name: Ditullio Residence Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlalBook: Builder Name: Rotate Angle: 0 Street: Lot 17 & 19 Gopher Rid Permit Office: St. Lucie County Cross Ventilation: No County: St. Lucie Jurisdiction: St. Lucie County Whole House Fan: No City, State, Zip: Fort Pierce , Family Type: Single-family FL, 34982 New/E)dsling: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO BEACH MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1975 18565 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Laundry 87 817.8 No 1 1 Yes Yes Yes 2 Master Bath 139 1306.6 No 1 1 No Yes Yes 3 AH 12 112.8 No 0 1 No Yes Yes 4 WIC 54 507.6 No 0 1 Yes Yes Yes 5 Hall 24 225.6 No 0 1 No Yes Yes 6 Master Bedroom 213 2002.2 No 2 1 1 Yes Yes Yes 7 Dining 216 2030.4 No 2 1 Yes Yes Yes 8 Kitchen 238 2237.2 Yes 2 1 Yes Yes Yes 9 Bedroom 3 198 1861.2 No 2 1 1 Yes Yes Yes 10 Bathroom 81 761.4 No 0 1 Yes Yes Yes 11 Bedroom 2 195 1833 No 2 1 1 Yes Yes Yes 12 Hall 36 338.4 No 0 1 No Yes Yes 13 Pantry 14 131.6 No 0 1 No Yes Yes 14 Great Room 468 4399.2 No 2 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpel 1 Slab -On -Grade Edge Insulatio Laundry 15 ft 0 87 ft' _ 1 0 0 2 Slab -On -Grade Edge Insulatio Master Bath 1 ft 0 139 ft' _ 1 0 0 3 Slab -On -Grade Edge Insulatio AH 1 it 0 12 ft- _ 1 0 0 4 Slab -On -Grade Edge Insulatio WIC 5 ft 0 54 ft' — 1 0 0 4/212019 10:47 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 2 of 6 'FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 5 Slab -On -Grade Edge Insulatio Hall 1 1 ft 0 24 ft2 _ 1 0 0 ' 6 Slab -On -Grade Edge Insulatio Master Bedroom 28 ft 0 213 ft2 _ 1 0 0 7 Slab -On -Grade Edge Insulatio Dining 12 ft 0 216 ft2 — 1 0 0 8 Slab -On -Grade Edge Insulatio Kitchen 12 ft 0 238 ft2 1 0 0 9 Slab -On -Grade Edge Insulatio Bedroom 3 30 ft 0 198 ft2 _ 1 0 0 10SIab-On-Grade Edge Insulatio Bathroom 9 ft 0 81 ft2 — 1 0 0 11SIab-On-Grade Edge Insulatio Bedroom 2 28 ft 0 195 ft' — 1 0 0 12SIab-On-Grade Edge Insulatio Hall 1 ft 0 36 112 — 1 0 0 13SIab-On-Grade Edge Insulatio Pantry 1 ft 0 14 ft2 1 0 0 14SIab-On-Grade Edge Insulatio Great Room 24 ft 0 468 ft2 — 1 0 0 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Metal 2139 ft2 0 ft2 Light 0.6 No 0.9 No 20 22.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 1975 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) laundry 20 Blown 87 ft2 0.1 Wood 2 Under Attic (Unvented) Master Bath 20 Blown 139 ft2 0.1 Wood 3 Under Attic (Unvented) AH 20 Blown 12 ft2 0.1 Wood 4 Under Attic (Unvented) WIC 20 Blown 54 ft2 0.1 Wood 5 Under Attic (Unvented) Hall 20 Blown _24 ft2 0.1 Wood _ 6 Under Attic (Unvented) Master Bedroom 20 Blown 213 ft2 0.1 Wood _ 7 Under Attic (Unvented) Dining 20 Blown 216 ft2 0.1 Wood 8 Under Attic (Unvented) Kitchen 20 Blown 238 ft2 0.1 Wood 9 Under Attic (Unvented) Bedroom 3 20 Blown 198 ft2 0.1 Wood _ 10 Under Attic (Unvented) Bathroom 20 Blown 81 ft2 0.1 Wood 11 Under Attic (Unvented) Bedroom 2 20 Blown 195 ft2 0.1 Wood 12 Under Attic (Unvented) Hall 2 20 Blown 36 ft2 0.1 Wood 13 Under Attic (Unvented) Pantry 20 Blown 14 ft2 0.1 Wood 14 Under Attic (Unvented) Great Room 20 Blown 468 ft2 0.1 Wood 412/2019 10:47 AM EnergyGaugeO USA Section R405A.1 Compliant Software Page 3 of 6 3' o o 0 o o 0 o o o o o o 0 0 0 0 o o v m C o C 0 C 0 C 0 C 0 C 0 C 0 C 0 C 0 C o C a C o m O N V Z Z Z Z Z Z Z Z Z Z Z O O O ¢ N N y �O t0 t0 t0 t0 t0 N N t0 N tD t0 �O t0 O O O o d d c 0 a t t m c 0 c m c m c 0 c m c m c m c m c m c w c N N N m O O Z O Z O Z O Z O Z O Z O Z O Z O Z O Z O Z E O O O O O O O O O O O O O O N N N ` C 15 �0 O O O LL N — LL C_ C L C 0 C C C C C C C C C C C w 1 L 0 v V v v v v v v v v v N a L - r - - r - tC — — — — — C' a C C C g C C a C C C C LL M j L C C C C C C C C C C C v N v M 0 0 eD M M •t O U O. C G C O G O G O O O G ? a W ❑ C C C C C C C C C r C N�< � � � .- � � O W �� N N T M N tp N N N N N N N f0 t0 W M 0 C C C C am! C Z. W Q f0 N _ C 0 m rn m rn m m rn m m rn rn rn m rn rn rn m a v w E z z z z z z z z z z z 0 0 0 0 0 0 0 0 0 0 0 0 0 0 c 0 — r o y Z O g yLL` N N N N N N N J Q 0 o c o 0 0 0 0 0 0 o c O y Q Q Oc O Z 0 N V' V V V V V 't Y V 'd' < V d' V" •' �'L" N t0 N N N N f0 N N N N N U y LL O O O C Ci o 0 0 0 0 0 a D M M M N N E ❑ 0 Z Z d d M c E E E o E E o Z' m E 0 E U d == 3 w `- O O C O U y y N y y N y N N N y N J J N N❑ Y y y d y d J J 9 9 J 5 S S J y in im y 22 C C C MC bCl C C C C C C C C C U' N Y •C W W W W W W W W W W N N N N N N N N N N N n a a n a D a a a a a O O V V U U V V V V V V a a a 6 O O O O O O O 0 O O O O O 0 O O 0 O O O O O O O O O O O T q❑❑❑❑❑❑❑❑❑❑❑ m m m m m m m m m m m m m m 3 9 3 a LL w w w w w w w w w w w ° oo o 0 0 0 0 0 0 0 0 0 0 V O O V V V U V U V V V O O E E E J J J J J J J J J J J C C C C C C C C C C C C C C y y N N O N N N N N W N W N N 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 y c c c c c c c c c c c c c m m m O 3❑ v N N n m ,N_, ¢ w urS u urS urS urS urS urS uT3 urS c� z m 3 z z z w w U) w w O z w 3 m 3 z z z w N w w 0(o z z z # ik N M v N �0 n w m 0 NI MI a NI NI nl OI OI OI �I �I �I �I �I NI 'I N v Ot a FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT GARAGE ' # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 441 ft' 441 ft' 21ft 9.4ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000418 2165.9 118.91 223.62 .318 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 27 kBlu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 29.4 kBtuthr cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None W DUCTS V # Supply— Location R-Value Area —Return Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT ON RLF HVAC# Heat Cool 1 Attic 6 120 ft' AH 10 ft' Default Leakage AH (Default) (Default) 1 1 4/2/2019 10:47 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 5 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES ProgramablThermostat: Y Calling Fans:Coolin �re Jan Venting Jan Feb rr� fr[` ]J [` ]J rl t[r` ]J fr[, Oct M rIE�]1 NOV Nov H Dec . [ ] lxl Mar lxl Apr [ May lXl Jun Jul lXl Aug lXl Sep lxl Oct Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Healing (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ft2 0 ft 0.3 Laundry Default(8 lbs/sq.ft. ft2 ft 0.3 Master Bath Default(8 lbs/sq.ft. ft2 ft 0.3 AH Default(8 lbs/sq.ft. ft2 ft 0.3 WIC Default(8 lbs/sq.ft. ft2 ft 0.3 Hall Default(8 lbs/sq.ft. ft2 ft 0.3 Master Bedroom Default(8 lbs/sq.ft. ft2 ft 0.3 Dining Default(8 lbs/sq.ft. ft2 ft 0.3 Kitchen Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 3 Default(8 lbs/sq.ft. ft2 ft 0.3 Bathroom Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 2 Default(8 lbs/sq.@. ft2 ft 0.3 Hall Default(8 lbs/sq.ft. ft2 ft 0.3 Pantry Default(8 Ibs/s .ft. ft2 ft 0.3 Great Room Name: Rating Compant: ... IL1llilllii)",,, : - r 4/2/2019 10:47 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 6 of 6 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Ditullio Residence Builder Name: Street: Lot 17 & 19 Gopher Ridge Road Permit Office: St. Lucie County City, State, Zip: Fort Pierce, FL, 34982 Permit Number: Y Owner. Dilullio Residence Jurisdiction: St. Lucie County w Design Location: FL, Fort Pierce c=i COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in an dropped ed ceiling/soffit Y the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind ninino and wirina. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or cellinat; a. In aaamon, inspection of log walls snail be In accordance with me provisions of IGG-400. 412/2019 10:47 AM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 89 The lower the Energy Performance Index, the more efficient the home. 1. New home of, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/AH 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 29.4 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1975 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.650 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.267 14. Heating system: Capacity 27.0 c) Area 7c. 180.0 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF OAS b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 4.1 0 Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 11.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans Yes a) Under attic 11a. 20.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be' stalled (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be cc ete e c installed code compliant features. // c Builder Signature: Date:/ l / Address of New Home: Lot 17 & 19 Gopher Ridge Road City/FL Zip: Fort Pierce, FL 34982 4/2/2019 10:47:48 AM EnergyGaugeO USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 o �- wrightsoftProject Summary Date: Entire House By: Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772466-6799 Email: quickcalcs®aol.cem Project11 • • For: Ditullio Residence Lot 17 & 19 Gopher Ridge Road, Fort Pierce, FL 34982 Notes: Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TO 28 OF Design TO 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/Ib Heating Summary Structure 20694 Btuh Duds 3616 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 24310 Btuh Infiltration Method Construction quality Fireplaces Simplified Average 0 Heat C1 975 Area (ft2) 1975 Volume (fta) 18565 18565 Airchanges/hour 0.38 0.20 Equiv. AVF (cfm) 118 62 Heating Equipment Summary Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 7.0 kW 23921 Btuh 22 OF 980 din 0.040 cfm/Btuh 0.50 in H2O Sensible Cooling Equipment Load Sizing Structure 17931 Btuh Duds 2456 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 19368 Btuh Latent Cooling Equipment Load Sizing Structure 5385 Btuh Ducts 1818 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 7203 Btuh Equipment Total Load (Sen+Lat) 26571 Btuh Req. total capacity at 0.70 SHR 2.3 ton Cooling Equipment Summary Make Trane Trade TRANE Cond 4TTR4031L1 Coil TEM6AOC36H31++TDR AHRI ref 7567544 Efficiency 13.0 EER, 16 SEER Sensible cooling 20580 Btuh Latent cooling 8820 Btuh Total cooling 29400 Btuh Actual air flow 980 arm Air flow factor 0.048 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.74 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrigAfrsoft 2019-Apr-0211:21:28 ACC -----.•-.-. Right-Suile® universal 201919.0.01 RSU08101 Paget ...ocuments\Wrightsoft WACUJitullio Resioence.rup Calc=MJ8 Front Door faces: S wrightsoft Right-M Worksheet Job: Entire House Data: Quick Calcs, Inc. By. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772466.6799 Email: quickcalcs@aol.com 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area Entire House 163.0 ft 9.4 ft 1975.0 ft- Laundry 15.0 ft 9.4 R heaUceol 1.0 x 87.0 ft 87.0 ft- Ty Construction number U-value (tit_ alU2 OF Or I HTM (Btuh/ft) I Area (ft') or perimeter (ft) I Load (Btuh) I Area (it') or perimeter (ft) I Load (Btuh) Heat Cool Gross I N/P/S Heat Cool Gross N/P/S Heat Cool fi 11 UUUrrr111 13A-0oce 4A5-20m 4A5-2om 4A5-2om 4A5-2cmd 0.143 0.770 0.770 0,770 _0.770 0.143 0.770 _ 0.770 n n n n _n_ a a 4.00 21.56 21.56 21.56 _21.56 4.00 21.56 2156 2.19 19.31 19.31 19.31 _19.31 2.19 43.77 45.10 479 5 9 15 __61 385 9 15 390 0 0 0 0 361 2 2 1560 97 19 323 _1319 1447 194 323 853 87 1 290 122 5 0 0 0 118 0 0 0 471 97 0 0 '258 87 0 0 __0 41 0 0 V)1 I�-GG 13A-4ocs 4A5-20m 4A5-20m _1182 791 394 677 19 0 0 __0 19 0 0 __ .0 75 0 0 --13A4ocs 4A5-20m 4A5-2om 11D0 13AAocs W-20m 22A-tpl, 0.143 0.770 0.770 __a s s s _s_ w _ =_ 4.00 21.56 21.56 -10.92, 4.00 21.56 �7.50 27.69 _ 2.19 19.31 19.31 _10.34 2.19 �45.10 _7.37 _0.00 _ 479 3 48 2020 188 _ 15 _79757975 1975 408 6 96 173 2 163 1634 65 1035 -223 693 323 -3131 M 4514 893 58 927 .�211 379 _677 �_2702 _ 0 '---0-- 0 0 0 0 0 - 0 --0 0 '0 0 _ 0 0 0 __0 0 0 _719 0 . Y)I _G _0.390 0.143 0770 �0.408 _,0.989 _,.0 0 0 0 _ 0 7 0 0 ^__738 .0_..18X79-0mE -87 _87 15 415 61 c) AED excursion 0 -22 Envelope loss/gain 17078 10291 1197 482 12 a) Imijuation b) Room ventilation 3618 0 1020 0 333 0 94 0 13 Internal gains: Occupants@ 230 Appliances/other 14 3220 3400 1 230 Sao Subtotal lines 6 to 13) 20694 17931 1530 1306 141ess exlemal load ess Uansis edistribution ubtotal uct foods 17% 14% 0 0 0 20694 3616 0 0 0 77931 2456 17% 14% 0 0 0 1530 267 0 0 0 1308 179 AiTotar requiredl(=) I I I 249310 80I 2038071 I I 1772I 1481I Calculations approved by ACCA to meet all reouirements of Manual J Sth Ed 1-rl&- !n�.�9ti=a,�>K,' 2019Apr-021121:28 c& Right -Suite® Universal 201919.0.01 RSU08101 Pages ...ocumentsWightsoR HYACIDilullio Residence.mp Calc=MJ8 Front Door races: S wrightsoftRight-M Worksheet Job: Entire House Date: Quick Calcs, Inc. By: 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-46M799 Email: quickcelcs@aol.cum 1 2 3 4 5 Room name Exposed well Room height Room dimensions Room area Master Bath a ft 9.4 ft heat/cool 1.0 x 139.0 It 139.0 fP AH 0 It 9.4 ft heat/cool 4.0 x 3.0 ft 12.0 ft- Ty Construction number U-value (Btuh/ft' Fj Or I HTM (Bt uh/ft� I Area (ft°) or perimeter (R) I Load (Btuh) I Area (it-) or perimeter (ft) I Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross I WP/S Heat Cool r6 8 71 4)/ II--�' 13A-2onn 4A5-tom 4A5-2om 4A5-2om 4A&2omd 0.770 0.770 0.770 0.770 _0.770 n n n n -n_ a a e 4.56 21.56 2156 21.56 -21.56 4.00 2156 21.5645.10 19.31 9.31 19.31 19.31 -19.31 2.19 43.77 0 0 0 0 --0 0 0 0 0 0 0 0 __0 0 0 0 0 0 0 0 0 0 0 0 .__.__0 0 0 0 0 0 0 0 -_0 0 0 0 0 0 0 0 __0 0 0 0 0 0 0 0 __-0 0 0 0 0 0 0 0 �.,._..0 0 0 0 13A-4oce 4A5-20m 4A5-20m 0.143 0.770 0.770 �0 0 0 0 wI�'''`,' I- ��� _ _ �- 13A�4= 4A5-tom 4A5-2om 11D0 _ 13A-4ocs 4AS-2om_ _16X19-0md_ ' 22A;lul__-__-_ 0.143 0.770 0.770 -0.390 0.143 0.770 -0.408 ___p.989 _ s s a _s_ w _w 4AD 21.56 21.56 -._10.92 4AD 2156 _1.54, _ 2.19'�'-U -'-2.19 19.31 19.31 _10.34 2.19 _45_10 1.37, - 0 0 _-0 0 0 -.139 _ 0' 0 0 __0 0 0 0 0 0 0 0 _0 _220 -0 0 0 _._0 0 0 -0 0 0 __0 0 0 12 0 0 0 __0 0 0 ._72 0 0 0 _ 0 0 0 0 0 lql =o .C_ F -0 0 _ _ 0. 79 _739 _ 190 ._,.___16 0 27.69 0.00 139 0 0 0 72 --0 0 61 c) AED excursion _7 0 Envelope loss/gain 220 183 19 16 12 a) Infiltration b) Room ventilation 0 0 0 0 0 0 0 0 13 Internal gains: Occupants (aj 230 Appliances/other 1 230 0 ti 0 0 Subtotal (lines 6 to 13) 2201 413 1 1 19 16 14 15 Less external load Less transfer Redistdbution Subtotal Duct loads 17% 14% 0 0 13 234 41 0 0 11 424 58 17% 14% 0 0 -19 0 0 0 0 -18 0 0 oad Airarequired(cfm) I I I �il 4I I I gl g Calculations approved by ACCA to meet all reauirements of Manual J Sth Ed w�f9!=cam o� 2019-Apr-0211:2 128 Right-Suite® universal 201919.0.01 RSU08101 Page ...ucumentslVJrighteoft HVACIDitullio Residence.rup Cale =MJ8 Front Door faces: S wrightsofr Right-J® Worksheet Job: Entire House pate: Quick Calcs, Inc. By. 317 SL Lucie Lane, Fort Pierce, FL 34946 Phone: 772466-6799 Email: quickcalcs@aol.com 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area WIC 5.0 ft 9.4 ft heaticool 6.0 x 9.0 ft 54.0 ft- Hall 0 ft 9.4 ft heaVcool 4.0 x 6.0 ft 24.0 ft2 Ty Construction number U-value (Bluhlfl"F Or HTM (Bluwft2) Area (1t2) or perimeter (ft) Load I (Btuh) Area (W) I or perimeter (ft) Load I (Btuh) Heat Cool Gross WP/S j Heal Cool Gross WP/S Heat Cool I 6 11 13XZM 4A5.2om 4A5-tom 4A5-2om AA5-2omd 13A-40cs 4A5-2om 4A5-2om 0.143 0.770 0.770 0:770 _0.770 0.143 0.770 0.770 _ n n - n n 4.00 21.56 21.56 21.56 21.56. 2.19 19.31 19.31 19.31 ___ 0 D 0 0 ___ 0 0 0 0 � 0 0 0 0 0 0 0 0 0 __ 0 0 0 0 __ 0' 0 0 0 0 0 0 0 _ _ 0 0 0 0 _ VI! �L{f' -n_ a a a 4.00 21.56 21.56 _19.31 2.19 43.77 45.10 -0 0 0 0 -0 0 0 0 -0 0 0 0 0 0 0 -0 0 0 0 ___0 0 0 0 _�._._0 0 0 0 _____0 0 0 - 13A-0acs 4A5-2om 4A5.2om .1.1D0 13A4ocs 4A5.2om ______ .16X79-0m1 22AjpL _ 0.143 0.770 0.770 5 s s _s,_ w _w_ = 4.00 21.56 21.56 _,10.92 4.00 21.5E _ .59. .i 2.19 19.31 19.31 -10.34 2.19 45.10 �1.37 0 0 0 0 0 0 0 0 0 0 0 0 -0 0 0 -0 0 0 0 0- 0 __a 0 0 0 _.____0 0 0 :_33 .0 F_ _ __0.390 0.143 �0.770 �0.408 __.,._0 47 0 54 __0 47 0 .__0 188 0 ^_e6 __._0 103 0 _74'�24 .__._._0 0 0 __00. 0 0 �24 0 0 r 38 ._54 0.989 _- 27.69 0.00 ___54 _ 5 138 0 r24 61 c) AED excursion _3 _1 Envelope loWgain 412 173 38 32 12 a) Infiltration b) Room ventilation ill 0 31 0 0 0 0 0 13 Internal gains: Occupants@ 230 AppliancestoNer 0 0 0 0 0 0 Subtotal (lines 6 to 13) 6231 2051 381 32 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 17% 14% 0 0 0 523 91 0 0 0 205 28 17% 14% 0 0 -38 0 0 0 0 -32 0 0 Air rel quired (cfm) I I I 6216 5I 211I I I 0I 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed -PW wrigtigofY 201OMi, 0211:21:28 Right -Suite® universal 201919.0.01 RSU08101 Page ...omments\Wdghtsofl HVACIDitullio Residence.mp Cale=MJ8 Frenl Doorfaces: 5 +wrightsoft• Right-J® Worksheet Job: Entire House Date: Quick Calcs, Inc. By: 317 St. Lude Lane, Fort Pierce, FL 34946 Phone: 772 .66-6799 Email: quickcelcs@aol.com 1 2 3 4 5 Room name F,xposed wall Room height Room dimensions Room area Master Bedroom 28.0 ft 9.4 ft heat/ocol 1.0 x 213.0 ft 213.0 ft Dining 12.0 ft 9.4 It heat/cool 72.0 x 18.0 It 216.0 fP Ty Construction number U-value (Btuhlfl'-'Fy Or HTM I (zh fP3 Area (ft') I or perimeter (H) Load I (Btuh) Area (fill I or perimeter (ft) Load I (Btuh) Heat Coal Gross WP/S Heat Cool Gross WNS Heal Cool fT I 6 71 ___T__ 13A-4ors- 4A5-2om 4A5-2om 4A5-tom 4A5-2omd- - 13A-4ocs 4A5-2om 4A5-2om 0.143 0.770 0.770 0.770 _,-__0.770 0.143 0.770 0.770 n n n n _n_ a a a 4.00 21.56 21.56 21.56 _21.56 4.00 21.56 21.56 2 19.31 19.31 19.31 _19.31 2.19 43.77 45.10 _.19 � 0 0 0 0 0 0 0 0 ---0 0 0 0 0 0 0 0 0 113 0 0 0 __61 0 0 0 52 0. 0 0 _____0 0 0 0 207 0 0 0 -1319 0 0 0 � 173 0 0 0 __,_1182 0 0 0 _ -0 0 0 0 -0 0 0 0 --0 0 0 0 0 0 0 F--G �p A- 134crs. 4A5-20m 4A5-2om 11D0 13A-4ace 4A5.2am .16X79-0m_ d 22A-Iol-„__ 0.143 0.770 0.770 s s s "s_ w w = 4.00 21.56 21.56 --10.92 4.00 21.56. -1.59. 27.69 2.19 19.31 19.31 122 0 12 110 0 12 441 0 259 241 0 232 0 0 0 0 0 0 - 0 0 0 -- 0 0 0 ___0 0 0 -296 0 t-G .C_ F _-0.390 0.143 -0.T70 -0.408 0.989 -10.34 2.19 45.10 ..4 ,1.37 0.00 ___0 141 _15 213 __213 --0-0--0 126 1 505 323677. _338 _775 276 _--291 0 ____.0 0 _ 0 _._216 216 -0 0 0 -0 0 0 _,342 -----,P32 _ _213 28 _ 216 12 61 0AED excursion 254 -36 Envelope losstgain 2641 1970 2201 7554 12 a) Infiltration b) Room ventilation 622 0 175 01 266 0 75 0 13 Internal gains: Occupants@ 230 Applianceslother 2 460 0 2 460 0 Subtotal (lines 6 to 13) 32621 2606 1 2467 2090 [Less 14 external load Less transfer Redistribution Subtotal Dud bails 17% 14% 0 0 24 3286 574 0 0 20 2626 360 17% 14% 0 0 6 2473 432 0 0 5 2094 287 oad TotaAir requiredmoml(cfm) I I I 3158I 2144I I I 295 1017I 21g4 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 'e'I'r' w�!191ti oR' 2019-Apr.0211:21:28 Right eside®Universa1=MJ8 Front oorfac01 Page4 ...ocumenls\WdghtsoH HVAC1Ditu1lio Residence.mp Cale =MJB Front Doorfaces: S F#f wrightsoft° Right-M Worksheet Job: Entire House Date: Quick Calcs, Inc. By. 317 St. Lude Lane. Fan Pierce, FL 34946 Phone: 772466-6799 Email: quickralcs@aol.com 11 2 3 4 5 Room name F°xposed wall Room height Room dimensions Room area Kitchen 12.0 ft 9A It heat/cool 1.0 x 238.0 ft 238.0 ft- Bedroom 30.0 ft 9.4 ft heallcool 1.0 x 198.0 ft 198.0 W Ty Construction number U-value I(Btuh/itz°F� IIF Or I HTM (Btuh/fl) I Area (W) or perimeter (ft) I Load (Btuh) Area (ft.) or perimeter (ft) I Load (Stun) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool fi 11 y% Ilflt---rrG _ 13A-flocs 4A5-20m 4AS2am 4AS2om 4A5-20md 13A.4ocs 4A5-2om 4A5-2om 0.770 0.770 0.770 0.770 _0.770 0.143 0.770 0.770 �n n n n -n-. a a a 4.56 21.56 21.56 21.56 _21.56 4.00 21.56 21.56 9.31 19.31 19.31 19.31 __19,31 2.19 43.77 45.10 170 0 9 0 --0 100 0 0 0 _-_0 410 0 184 0 0 220 0 174 0 _-_0 132 0 0 15 -0 777 0 0 0 .-0 -487 0 0 323 -0 255 0 0 290 --..0 308 0 0 0 0 0 0 0 0 0 0 0_ 0 0 0 141 0 0 141 0 0 565 0 0 _ 13A.1ocs. 4A5-20m 4A5-2oin 1,1D0 0.143 0.770 0.770 s s s -ate w _w ;._ 4.00 21.56 21.55 -10.92 4.00 21.56 -1.59 27.69. -2.19 19.31 19.31 0 0 0 0 0 0 0 ^- 0 0 0 0 0 0 0 9 0 0 9 0 0 -- 38 0 0 21 0 0 ___-_0 0 0 _v_.27.1 0 Vrf 13A-0ocs 4AS2onn -16X79:Omd___ 22A-tpl____ __0.390 0.143 0.770 -0.408 _0989 ,_10.34 2.19 _45.10 _7.37. 0.00 -0 0 0_ 0 0 0 0 � 377 332 _0 0 0_ �0 0 0 e0 0 0 _,_.0 0 0 C_ F _._238.__238 238 12 .�326 0 98198 198 30 _ ___314 ._831 61 c)AED excursion -55 -30 Envelope loss/gain 1319 672 2537 1115 12 a) Infiltration b) Room ventilation 266 0 75 0 1 666 1 0 188 0 13 Internal gains: Occupants @ 230 Appliances/other 2 460 2110 2 460 0 Subtotal (lines 6 to 13) 1 15861 32071 1 1 3203 1762 14 15 Less extemal load Less transfer Redistribution Subtotal Dud leads 17% 14% 0 0 4 1590 278 0 0 4 3211 440 17% 14% 0 0 9 3212 561 0 0 7 1770 242 AIr requ'ued (Cm) I I I 1875I 3175I I I 3152I 2097I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed �}► wrlgto�o.T 2019.Apr.0211:21:28 Right -Suite® Universal 201919.0.01 RSU08101 Page ...ocumenlslWrightsoft HVACIDilullio Residence.mp Cate=M.18 Front Door faces: S wrightsoft• Right-J® Worksheet Job: Entire House Date: Quick Calcs, Inc. By: 317 St Lucie Lane, Fort Pierce, FL 34946 Phone: 772466-6799 Email: quickcalcs@aol.com 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area Bathroom 9.0 ft 9.4 ft heat/cool 9.0 x 9.0 ft 81.0 ft Bedroom 2 28.0 ft 9.4 ft heat/cool 13.0 x 15.0 It 195.0 ft- Ty Construction number U-value (Btuh/ft"FI IOr H7M I (BtuNft� Area (ft') I or perimeter (ft) Load I (etuh) Area (ft') I or perimeter (ft) Load I (BNh) Heat Cool Gross I NIP/S I Heat I Cool Gross I NIP/S Heat Cool 1 fi 11 13A-40ds 4A5-2om 4AS-20m 4A5-2om 4A5-2omd_,__. 13A-0ocs 4A5-tom 4A5-20m 0.143 0.770 0.770 0.770 __-0.770 0.143 0.770 0.770 n n n n -n_ a a e 4.00 21.56 21.56 21.56 _.21.56 4.00 21.56 21.56 2 19.31 19.31 19.31 _19.31 2.19 43.77 45.10 �� 0 0 0 0 --0-0 85 9 0 0 0 0 0 76 1 0 0 0 0 0 __ 0 0 0 0 0 _ 0 0 0 0 0 0 0 0 -0 126 0 1 0 0 0 0 --.__0 505 0 323 v'.19 0 0 0 0 ._ W tG ._0 303 194 0 165 394 0 -0 141 0 15 _0 276 0 677 13A-4oes 4A5.2om 4AS2om '.11DO 13A-40cs 4A5.2om .16mg:Omtl 22A-Ipl__ 0.743 0.770 0.770 ,0.390 0.143 10.770 -0.400 0.989 _ s s s _a_ w w_ __- 4.00 21.56 21.56 _10.92 4.00 _21.58 _1.59. 27.69 2.19 19.31 19.31 _10.34 2.19 45.10 _7.37, _0.00 �� 0 0 0 0 0 0 0 0 __ 0 0 0 0 0 0 0 ___ 0 0 0 ___111 __ 122 0 12 -0 0 0 _195 170 0 12 0 __ 441 0 259 __0 0 _ _0 �309 _ J 241 0 232 _._.0 0 0 . _267 Vy/ �G C__ F _ -0-0 0 0 �81 ^_81 0 ,0 �728 0 0 -t95 _81 _ _ 9 249 ---0 __795 -28 775 _ 0 61 c)AED excursion -5 -39 Envelope loss/gain 874 665 i i 2612 1653 12 a) Infiltrallon b) Room ventilation 200 0 56 0 622 0 175 0 13 Internal gains: Occupants@ 230 Appliances/other 0 0 0 2 460 0 Subtotal (lines 6 to 13) 1074 721 1 3234 2288 14 15 Less external load Less transfer Redishibution Subtotal Dud loads 77% 14% 0 0 20 1094 181 0 0 17 738 701 17% 14% 0 0 9 3243 587 0 0 7 2296 314 TolaAir requf dI(cbn) I I 7252I 81 840I I I 31096101 54I 2125 Calculations approved by ACCA to meet all requirements of Manual J 811h Ed. w�Igls�s- 2019-Apr-0211:21:28 ►S Right -Suite® Universal 201919.0.01 RSUD8101 Page ...ocuments\Wrightsoft HVACIDilullio Residence.rup Calc=We Front Doorfaces: S I# wrightsoft Right-J® Worksheet Job: Entire House Date: Quick Calcs, Inc. By. 317 St Lude Lane, Fort Pierce, FL 34946 Phone: 772466-6799 Email: quickw1cs@aol.eom 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area Hall 2 O ft 9.4 H heat/caol 4.0 x 9.0 ft 36.0 n2 Pantry O ft 9.4 If heat/cool 1.0 x 14.0 ft 14.0 H2 Ty Construction number U-value (Btuh/ft"F Or I Him (Btuh/ft) I Area (n2) or perimeter (ft) I Load (Bluh) I Area (ft.) or perimeter (ft) I Load (Bluh) Heal I Cool Gross !P Heat I Cool Gross f4/P/S Heal Cool � 6 11 ._ W I�-GG ocs 13A-fl 4A5-20m 4A6-2om 4A5-20m .4AS2omtl 0.143 0.770 0.770 0.770 0.770 0.143 0.770 0.770 n n n n _n_ a a e_ - 4.00 21.56 21.56 21.56 _21.56 4.00 21.56 21.55 - 2^ .19 19.31 19,31 19.31 -19.31 0 0 0 0 .__O 0 0 0 0 0 0 0 __O �- 0 '0 0 0 0 0 0 0 0 __O 0 0 0 0 _O 0 0 0 0 __O 0 0 0 0 -0 -� 0 0 0 0 ,.,___O 13A-flocs 4A5-2om 4A5.2om 2.19 43.77 45.10 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 13A4= 4A5-2om 4A5-2om .11D0__ 0.143 0.770 0.770 -0.390 s s 3 ,ems_ 4.00 21.56 21.56 -10.92 2.19 19.31 19.31 ,10.34 0 0 0 0 0^ 0 0 _.___0 0 0 0 _._0 0 0 0 -0 0 0 0 -0 0~ 0 0 ,_ _O 0� 0 0 ___p _ �0 0 0 -0. l�/ =G 13A-40= 4Ai2om .i8X19:Omtl'� 22A:tpl 0.143 ^,0.770 _0.408 ____0.989 w w_ _:_ - 4.00 21.56 _-1.59. 27.69. 2.19 45.10 -1.37 ---0.00 0 i0 -36 36 0 0 0 0 __57 0 __ 0 _ _49 0 0 0 0 0 _=14 0 0 _e 0 __.-19 -C__. __36 __14 _14 �0 -22 0 0 0 0 0 61 0AED excursion 1 -1 0 Envelope loss/gam 1 57 48 22 19 12 a) Infiltration b) Room ventilation 0 0 0 0 0 0 0 0 13 internal gains: Occupants(P 230 Appliancestother 0 0 0 0 0 0 Subtotal Oines 6 to 13) 57 48 22 19 14 15 Less external load Less transfer Redismibution Subtotal Duct loads 17% 14% -5 g 0 0 48 0 0 17% 14% 0 0 9 31 5 0 0 7 26 4 Alr rel gru�iretll (cfrn) I I I 0I 0I I I 31I 31 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -�/- =11st soft 2019-Apr-02 11:21:28 Right -Suite® Universal 201919.0.01 RSU08101 Pagel ...ocumentsWfightsoft HVACIDitullio Residence.rup Gale =MJ8 Front Door faces: S wrightsoft Right-M) Worksheet Job: Entire House Date: Quick Calcs, Inc. By: 317 St. Lucie Lane, Fort Pierce, FL 34M Phone: 772466-6799 Email: quickralcs@aol.cam 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area Great Room 24.0 It 9A ft heat/coot 1.0 x 468.0 ft 468.0 fP Ty Construction number U-value (Btuh/fle T1 IOr HTM I (Bluh/ft-) Area (fP) I or perimeter (it) Load I (Stuh) Area I ofperimeter Load Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Co.] - -�T 6 11 1M 11111.-----'rG^G'= �G 13A-flocs 4A5-tom 4A&2om 4A&2om 4A5-2amtl 13A-flocs 4A&2om 4A5.2om -0.143 0.770 0.770 0.770 _0.770 0.143 0.770 0.770 n n n n _.n_ a a a 4.00 21.56 21.56 21.56 21.56 4.OD 21.56 2156 ' 2.19 19.31 19.31 19.31 _19.31 2.19 43.77 45.10 0 0 0 0 __-0 0 0 0 0 0 0 0 0 -0--0 0 0 0 0 0 0 0 __-0 0 0 0 0 0 0 0 0 0 13A-40cc 4A5-2em 4A&2om 11D0 _ 0.143 0.770 0.770 0390 s s a �s_ 4.00 21.56 21.56 _10.92 2.19 19.31 19.31 _10.34 �226 3 24 _20 178 3 24 _20 _ 714 65 517 _223 390 58 463 --211 -- --- y! C,. F 13A-4ocs 4A&2om l6X1Mad ___ 22A;tol____ 0.143 _0.770 ___0.408 0.989 w w _ _._ 4.00 21.56 _.-1.59 _27.69 2.19 45.10 - 1.37 0.00 0 0 _ 468 _468 0 0 0 0 0 _468 _ _-24 742 _665 _0 _640 0 _ 61 c)AED excursion -55 Envelope loss/gain 1 2925 1707 12 a) Infiltration b) Room ventilation 533 0 150 0 13 Internal gains: Occupants@ 230 Appliances/other 2 460 900 Subtotal (lines 6 to 13) 3458 3218 14 15 Less external load Less transfer Redistribution Subtotal Dud leads 17% 14% 0 0 21 3479 608 0 0 18 3235 443 Nrreq�o tll(chn) I I I 4085I 36��I _ Calculations approved by ACCA to meet all reOuirements of Manual J 8th Ed. - wrM1gtiesotiC' 2019Apr-0211:21:28 A RightSuilelf Universal 201919.0.01 RSUD8101 Page ...ocumentsXMghlsoft WACIDilullio Residence.mp Cole =M.18 Front Doorfaces: S �- wrightsoft° Duct System Summary Entire House Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierre, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com For: Ditullio Residence Lot 17 & 19 Gopher Ridge Road, Fort Pierce, FL 34982 External static pressure Pressurelosses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.276 in/100ft 980 cfm 181 Job: Date: By: Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.276 in/100ft 980 cfm Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Mad Actual Ln (ft) Ftg.Egv Ln (ft) Trunk Bathroom h 1285 52 40 0.293 6.0 Ox0 VIFx 35.7 135.0 st3 Bedroom 2 h 3809 154 125 0.276 8.0 Ox 0 VIFX 46.3 135.0 st3 Bedroom h 3773 152 97 0.288 8.0 Ox0 VIFx 38.8 135.0 st3 Dining h 2905 117 114 0.359 7.0 Ox 0 VIFx 24.4 115.0 st1 Great Room c 1839 82 88 0.351 7.0 Ox0 VIFx 27.3 115.0 all Great Room -A c 1839 82 88 0.351 7.0 Ox 0 VIFx 27.3 115.0 stl Klchen c 3650 75 175 0.367 8.0 Ox 0 VIFX 21.1 115.0 stl Laundry h 1797 72 71 0.388 6.0 Ox 0 VIFx 13.8 115.0 st2 Master Bath c 483 11 23 0.410 5.0 Ox0 VIFx 7.1 115.0 st2 Master Bedroom h 3860 156 144 0.379 8.0 Ox0 VIFX 16.8 115.0 st2 PWtry c 36 1 1 0.290 4.0 Ox0 VIFX 37.2 135.0 st3 vmc h 615 25 11 0.397 4.0 Ox0 VIFx 10.9 115.0 st2 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (drn) (cfm) FR (fpm) (in) (in) Material Trunk st3 Peak AVF 359 264 0.276 457 12.0 0 x 0 VinlFlx st1 st1 Peak AVF 716 731 0.276 684 14.0 0 x 0 VinlFlx st2 Peak AVF 264 249 0.379 484 10.0 0 x 0 VinlFlx wrightsof - 2019.Apr.0211:21:29 �1- .,.... ....�o.,� Right -Suite® Universal 201919.0.01 RSUC8101 Page 1 M..I.F...oaments\WdghtsoH RVAC%Ditullie Residence.rup Cale =MJ6 Front Doorfacas:S Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FIR(fpm) Veloc Diam (in) H x W (in) Stud/Joist Opening (in) Duct Mall Trunk rb1 Ox0 980 980 0 0 0 0 Ox 0 VIFx $ wri htsofV 2019-Apr-0211:21:29 .....�9 ....�...." Right -Suite® Universal 201919.0.01 RSU08101 Paget �+� ...oamentslWrightsoft WAODitullio Residence.rup Calc= MJ8 Front Door faces: S