Loading...
HomeMy WebLinkAboutGENERAC PAPERWORK�/ __ FILE C®PY GENERAC Q INCLUDES; St. LUCle True Power- Electrical Technology JUN, 2 0 90,19 GUARDIAN® SERIES Residential Standby Generators Ide.Eaeniiy, Parmlttm9.. .Air -Cooled -Gas Engine 'bung' Standby Power Rating Models G007036-0, Go07037-0 (Aluminum - Bisque) = 16 kkV 60 Nz • Two Line LCD Multilingual Digital Model G007035-0 (Aluminum - Bisque) - 16 kW GO H? Evolution TM' Controller (English/Spanish/ Mode's G007030-0,. 0007038-0 (Aluminum - Bisque) - 2010 60 H_ French/Portuguese) ��� 1'40ddS COO' r.'. ', ' v4� (F , ,G4Tt - ul q y - 22 "., �I ti • -Two Transfer Switch Options Available: / 100 Amp,,16 Circuit Switch or SULICIE COUNTY an—W 200 Amp Service Rated Smart Switch. PLAN REV "' d See Page 4-for Details. • Electronic Governor BLDG: • System Status & Maintenance Interval LED Indic DATE- ti • Sound Attenuated Enclosure t < GENERAC' DATE: -Zo /°y HeAble Fuel Line Connector Direct -TO -Dirt Composite Mounting Pad • Natural Gas or LP Gas Operation • 5 Year Limited Warranty Capability to be installed within 18" (457 mm) of a building*. PLUMB: 'Jx DATE: R12—i . ... _. MECH: DATE: c - us 0UI T—TES LISTED �� I LJ.J Note: CUL cenlar a"on only xppGes ro unb,sWled units and mils Ndaged withli sited circuit SLIlydleS. Unilspzclaged will NC Sayrt Swilcham UL cerlllied in the USa only. -CrJy 10,Cated doors, sa-M1 •rp. kesi, airN.�as, -aitd uNees attar- ,Mi a dimted W local codes. FEATURES ,-y INNOVATIVE WSIGII S PR@TO?yr LTESrING are key components or SUI.10 SiATc.€TIL 1 E;JCY CO!: c..sATGJ V lLY1G'c iEvUl u73pq, Thissla e GEN there. Totasucl commils in IMPPo componING WERRYDESIGN.'Bue tang, doesn't af-the-art power maximizing regulation system isslandard an all Generale modala,it slap there. TolatcommiMenTlo component testing, reliability Testing, provides optimizedFASTRESPONSE to changing load conditiehs and MAXIMUM environmental testing, destruction and life testing, plus testing to applicable MOTOR STARTING CAPABILITY by electronically longue -matching the surge CSA, NEMA, EGSA, and other standards, allows youto choose GENERAC loads to the engine. Digital voltage regulation atst%. POWER SYSTEMS wida the coniidence'lh tthese systems willprovide supedor perfprrJgnce. SINGLE SOURCE SERVICE RESPONSE from Generac's eid �ve d I TRUE PU1,Er1" ELECTRICAL TECHNOLOGY: Superior hamwhics andsine wave form produce lessthan 5%Total Harmonic Distortion for utility quafdy power. This allows confident operefion of Sensitive elearoric er14rameat and mIcro-chip based apfiliances, such as variable speed HVAC sysfarns; 7 TEST CRITER.fA: PROTOTYPE TESTED BEMA MG1-22 EVALUATION, SYSTEM TORSIONAL TESTED MOTOR STARTING ABILITY Provides ensr ea er nehvork p Paris and Service knmv-how for the entire unit, Mm:fhe engine to, smallest elecrionic compormoL GEUERAC 7 RANSTER Long life and reliability are symmyrnou with GENERAL. POWER SYSTEMS. One reason for this confidence is that the GENERAC product line includes its own transfer systems andcontrolsfor tdfal system compatibility. w GENERAC �^t'' cw+��� PROM i � d w Link ru•varm. tisu woyeancrcnm rwtan emv. GENERAC' 16/20/22 kW available accessories Model# Product Description G006463.3 Mobile Link'" Generac's Mobile Link allows you to check the status of your generator from anywhere that you have access to an Internet connection from a PC or any smart device. You wiifeven benoti6ed via e-mail or tend message when a change In the generator's status occurs. Available in the LLS. only. 6005819-0 26R Wet Cell Battery E'+-rY standby yenetzlur requires a bailery lu siuis Ulu systrnt Gutroiau ugers gee ieconeaended 26R wet Celt battery for use wlrh an air-cooled standby product (excluding PowerPactq. G007101-0 Battery PadWarmer The Pad warmer rests under the tatteryRecommended for use dthe temperature regularly falls below.0°F. (Not necessary for use with AGM -style batteries)-. G007102-0 Oil Warmer Oil warmer slips directly overthe oil filler. Recommended for use it Hie tempefature regularly falls below 0°F.' G007103.6 Breather Warmer The breather war merisfor use ineldremecold weather applications. For.usewith_ Evolution - controllers only in climates where heavy icing occurs. --- G005621-0 Auxiliary Transfer Switch Contact The auxiiary transrer switch contact kit alinws the translerswitch to lock auto single large electrical Kit load you may need. Not compatible withf50 amp pre -wired switches. G007027-0-Bisque Fascia Base Wrap Kit the fascia base wrap snaps together around the_bo0om of the new air cooled generators. This offers (Standard on 22 kMj a slee$ contoured appearance as well as offering protection from rodents and insects by Covering the' i f8ng holey iccalrd,inthe base. 130057010-Bisque paint Kit If the generator enclosure Is scratched or damaged, itis important to touch -lip the paint tti protect from future corrosion. The paint lit includes the necessary paint to property maintain or touch-upa generatarenclosure. G606485-0-16,208 a-ciieduied irsain[oram;e Kd 22 kW Genes scheduledto maintenance lots provide a➢ the hardware necessary complete perform routine maintenance on a Generne automatic standby generator. G006873.0 Smart Management, Module Smart Management. Modules an used in conjunction with the Automatic Transfer Switch to (50 Amps) 'Increase Its power management capabilities. It provides additional power management 0exihflity not found in any other power management system. dimensions & UPCs DimenaixteSM¢marexPNan�tele. eeNr lot rfmBlninual fin exatl direy¢,p�: eONOTIISETIE%DM319triefan NUALUTIONRaiPa56t. -model UPC 6G07035-0 '-696471070354 G007036-0 696471070361 G007037-0 696471070378 13007036-0 696471070385 G007039-0 G007040-0 696471070392 696-471070408 G007042-0 596471070422 6007043-0 696471070439 ¢E .DEMEW GEN EP-AC' Generac Power Systems, Inc. • S45 W29290 HWY.. 59, Waukesha, WI 53189 • geneme.cdm ®Lll6 GaieBe Poxa SySane,lne. MIpIL9re�vol.M�ecvieaaom areeutj¢dID elvnge wWwulnotice. 6U&emleeeBBee174B 05r16l18 GrY.rltlWER/• C* = 1 16/20/22 kW switch options Limited Circuit Switch • 16 circuits. • Electrically operated, mechanically -held contacts for fast, positive connections. Rated for all class of;Nd, 1 uG% equipment rated, bath Inductive and rslsiiva • 2 pole, 250VAG contactors. • 30 millisecond transfer time. • Dual coil design. • Hated for -both copper and aluminum conductors. • Maim contacts are silver plated or silver alloy to resist welding and sticking. • NEMA.3R aluminum outdoor enclosure allows for indoor or outdoor mounting flaxibibt9 •:Multi listed for use with 1• standard, tandem, GFCI and'AFCI breakers from Siemens, Murray, Eaton and Square D for the most flexible and cost effective install. Dimensions Model GBH7036-0 (16 kW) No. of Poles 2 CumantHating (Amps) 100 Vallage Rating (VAC) 1201240,10 Ulilitl Vollaoe Monitor (Freir- -H'c4-uP '80% -Dropotd 65% Realm to right- alim 15 sec. Exercise 6i-sveekly ter 12 minutes- Standard OLLisied Standard Imal of rrcwaed circuit 16 No. 15 A.120V 5 No. 20A 120V 5 No. 20 A240V 1. No. 30 A240V - No. 40A24pV 1 No. 50 A24p:V 1. Tandem Breaker capability .8 spaces Ciouil Brea!uar Protected Aiatlable RMS Symmelrleal Fault Contend 9.250 Veils 10,o00 -Function of Evolution CoNmller Ewase can beset to reckly or monthly. 200 Amps 120,24o, to 0 en Transitions, -Hated .. Height Out Depth ]itN2 Nil IN2 In 27.24 30.0 11.4 _13.5 7.09 .. mm WU 762.4 289.0 I 3430 I1800 i. Wire Ranges - ' Canductour but Neutral Wg Ground Lu 2y0-; 14 210-214 2/0-1-14 I - SPi'VIC0 Rated Erik ll Sivitch Features • Includes Digital Power ManagementTechnology standaN_(02M): • Intelligently manages up to four air conditioner loads wiih no additional hardware. • UP to four more large (240 VAQ loads can be managed when used in :conjunction wllh:Small Management Modules (SMMs). • Electrically, operated, mechanically -held contacts for fast,,ctean connect Model G007037-0.(16 W410007039.0 (20 kW)/ 6007043.0 (22 kW) No: of Pulse, Cunha Rating (Amps) Voitage Rating (Viz) UItity Voltage Monitor (Fbaso, nft ip 0mpour ons, Return to utility' • rated for all classes of tied, 100% cquipnlenf rated. both inductive and resistive. - - rmriseweekly to to ti2tes- UL Listed • 0010 four more large (12u/240VAG) loads can be marten wtieo used in ccniunctionWith 6damp .Power Management Modules '(PMM•`). ' • 2 pofer 250 VAC:coohclors. Enclosure Type LugHrldPalirig(Amps) Lug znOe 'Function Of{voiulion Controller • Service equipment rated, dual coil design: • Rated for both aluminum and copper conductors. • NEMA3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. • Main contacts are silver plated Or silver ahoy to resist welding and stiddng. Dimensions 206 Amps 120/240,.10 Open Transition Service RateH Height Width H1 H2 r WI l52 .Depth _ in 27.24 30.9 11.4 13.5 7.09 rnm - 6920 762:4. 289.0 343a 1 180.0 2 200 120,e40. 1u. .Bit% 65% approk 13 sec. sl Mxd Standard NEWUL 3H 22,een 250 MC.M'- L6 16/20/22 'knit Gcncrator Model lGE11 ERACe Gp07035-p, G007p36-0, GgG7p3B•p,.Gpp7p39-p`V Gp07842-0. 00079434 Rated Maximum Conditioning;Parer Capacey (LP) 0007037-0..(16 kW) (20,ik (22-kW) Rated Maximum Continuous Power Capacity ING) 16,000 Walls• 2D OW Walls• 22,000 Wags' Rated Voltage 16,000 walls, 18,000 Walls• 19,500 Watts• Rated'"rimnr CunlfOopos load .Cuuatl-240 Voila (LPMG) 240 240 240 bllot HarmoniIa Distortion 66.6ioo"."e 63."s?5 9i.240 .Main Line Circuit Breaker Less than 5% Less Run 5% Less Than 5% Phase 70Amp 1q0 Amp 100 Amp Number of Rotor Poles 1 1. 1 R; - AC Fmgaan.:y 2 2 2 Power Factor E.ON. ER Ti. E1uLL Battery. Requirement (not induded) 1.0 li0 1.0 Unit Weight (ib/kg) 12 Vo11s, Group.26R 54O CCA Minimum arGoup35AGM 65OCCA Minfmum Dimensions (L x W x H):fair= 409ABE 1448/203 466/211 Cn'-^nd a!'IguUn dn(A)gL?3 R: (7 an, with n gnna[ m mrarjlg al mrpnl load^+ 48 x 25.x 29/1218 is 638 x732 Sound output in ORIN at 23 it (7 m) with generator in Quiet--Teal"law-speed _0 An -- n7 exercise made" - 58 Exercise duration 58 58 5 min 5mip 5 mid Ename 75We at Engine .Number of Cylinders :GENL7iAC OHVI V-1tiV!N GENERAL OHVI VaWiN GENERAC.OW V-1�VIN Displacement ,2 2 2 Cylinder Block 999 cc 999 cc 999 cc Valve Armnpement Aluminum w/Coal [ran Sleeve Ignition System overhead Valve Overhead Valve Overhead Valve Governor System Solid -stale w/Magnelo Solid-state w/Mailman Solid-state a/Malpato Compression Ratio Electronic Electronic. Electronic Starter 9.5:1 9.5.1 r. 9..1 u Oil Capacity Including Filter ter 12 Vale 12 Vdc 12Vdc Operanmg rprd Appmc 1.9.gV1.8 L Approx 1:9 g1,11.8 L App* 1.9 QV1:8 L Fuel Consumption 3.650 3,600 3,600 Natural Gas 93PorW/ho Full Load LiauitlPmoane R3/ki (gatfir)(l4,rl 993 (5.47) 312(8.83) 205 (5-8) 308(8:72). 18-0 (5.21) 281(7.96) 112 Wad Full Load Nole:Fual pipe must be sized for full load. Required fuel Eli (19) [74 116 (3.19)112.071 81 (2.23) 18.45) 140 (3.BSI.It4.57] 78 (2.16)18.16). 134 368 13.94 ( )( 1 measure To generator fuel:WEI at all load raves_umn am merc 37.for d Aaz' maary) far LP gas. For Btocout m inpty R3/nrz 2500 8P) or83rhrx 1000 INS). ForMega(aula cone nt.;?wllipl• mr/brx193;16 1D-12-water column (19-22 man (LP) or m7-13 26 (MOj 2-Une, Plain TPA Multilingual LCO.Display Made BuIlolr ANo. Manual, OB W,* In 91mV14aicl0=1 Maidnuc Engine RunNamsjudimlioe Programmable start delay tietween 2-159D sculls Utility Voltage LOVAglum 10 UlililyAdlustable (BravmomSe'il'ing) fulune Set Capable ExemiseUEOcise Set Eirar Warning Run/AlumWalnumedce taps Engine Start Sequence Slarter lock cut Smarl Bakery Charger Charger Fau!mssiog AC Waning Low &IleryrBafteryProblem Pmleigan and Battery Cona[mn radiation Pa!ema!s Yenzpe?eg!gg'ioe e.^'@ O:brad Lied_, w.g:ge.°x!^c0an Under-Frequency70valoed/Slepper OvemVdent Prblection Safety Fused/Fuse Problem Protection Automatic Lon Oil Pressure/High 01 Tamm alum Shutdown OvaoanWOvenpeed1U72 Hz)/rpm Sense Loss Shuldavm High EnQua•7ampgxium Shuldmvn Internal r4milinraned Wu6g Pmhel'ron.. Common External F uh Capab8fry Field Upgradable Formato Simple user inlaface for ease of operation. Automatic Sl3nom Utility fauna, 7 day exerciser. Srad with salter obmml,mot slays on, It ul8!ry Wis. uaWw Id load fakes place. Slops uo1L PoWenIs remored. Conbol and chanda.s00 operate. Sa mud Standard Standard (programmable by dealer only) From 1NWI V/190-216 V Standard 50Events Each Cyclic crardung: 16 sec on, 7-rest (90 sec maAmum dmu h r). Suater aamntwe gape tWil5 sec after engine 'has slopped. Standard Skendard Standard ota na,n Standard Slzndam Standard. Standard Standard Standard Standard Standard 15/20/22 kW features and benefits Engine, •Geaerac (OHVI) design Maxim¢es engine "breathing" forincreased fuel efficiency. Plateau honed cylinderwalls and:plasmamoly rings helps.the engine ran center; reducing oil consumption resulting in longer engine. life- * Quiet Test" Greatly reduces sound output and fuel consumption during bi-weeklyexercise. >"Sp1ny4c "cast iron cylinder vva!Is r : Rigidcenstuv iar� and:added d =rabih;g;p� d-tang u;,g:a life. -Electronic ignition/spark advance These features combine to assure smooth gmckstarting every time. •Full:pressure lubrication system Pressurized lubrication to all vital bearings means bettei,performance,less mainlenanca and longer engine life. ' Now.featuring up to a 2-year/200,hour oil change interval. -Law oil pressure shutdown system ShutdownProtectionprevents catastrophic engine damage due to low oil. -High temperature shutdown Prevents damage due to overheating. Generator ,. -Revolving field -Skewed : stator • Displaced phase excitation •Automatic voltage regulation •UL 2260 listed Allows for a smaller, light weight unit that operates 25% more efficiently than a revolvingarmature generator. Produces;a smooth output warveform forcompatibifity with electronic equipment. Maximizes motor starting capability. Regulates the output voltage to±l%,Prevents damagingvolloge spikes. Eoi your safely. Transfer $•.Bich -Fully automatic Transfers your vital electrical loads to the energized source of power. •Rem.!-mcuntinn _ n Agl: h P.cunLrea.•yarreexis"ng,. .,atior.-r-re!Tcrs!mple,'nty-cost.^Stallatlor.. •,NEMA 3R Can be`installed imide or outside for maximum flexibility. Evolution""Controls •AulWanuaV00 illuminated' buttons Selects the operating mode and provides easy, at -a -glance status indication fn any condiffan. -Two-line LCD multilingual display Provides homeowners easily visible tags of history, maintenance and events up to 50 occurrences. -Seated, raised. buttons Smooth; weather -resistant use[ interface for programming and'operations •Utility voltage sensing, Constantly monitors utility voltage, selleo'rnts 65%dropout, 80%pick-up, of standard voltage. Ge fraiai voltage sensing GMsLuRiymoniims,geaeiaiur voltage toenstat. Me deanust puwe deiivared 10 fire hume. •.Ut!lityinterrupt delay Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting at seconds by a qualified dealer. -Engine warm-up Ensures engine is ready to assume the load, setpoim approximately 5 seconds. E'Igine coat -down ngaFiSe: lfie iedWl, p,iuriashafduWri;.S& am:a ? P Pp!uW:Tm,efy. minnfe. -Programmable exerciser .Operates engine to prevent oil seal drying and damage between power oulages byrunning the generator fors minutes every alherweek. Also offers a selectable selling for weekly or monthly operationproviding flexibility and polentially lower fuel costs to the owner. -Smart battery charger Delivers charce to the battery onlywhen needed atvarving rates depanding on outdoor airtemperalarre. Compatible with lead acid and AGM -style batteries. •Electronic.goyemor Maintatnsconstant 60Hzfrequeocy., Urdt -SAE weaiiier pmtectiveeuciosare Sound attenuated enciosures unsure quiet operation and.pMeci onagaiost mother nature, wi0utanding rdnds up to 150 mph. Hinged key tacking roof panel for security.. Lift -out front for easy access to all routine maNuedance items:, Electrostatically applied textured epoxy paint for added durability. -Enclosed critical grade mulfler Quiet, critical grade muffler is mounted inside theonitto prevent injuries. Smal-i, compacf attractive klakv"af&aneasy, eye a _ ppealmu inslaJabbn as close asl8 away aom a haddina: • 1 It (305 mm) flexible fuel line connector Absorbs any generator vibration when connected; to rigid pipe. -Direct-to-dirt.composite mounting pad Complex lattice design: prevents settling or sinking of [he generator system. -Integral sediment trap Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine fife. HURRICANE CONCRETE PAD FOR GENERAC GENERATORS (GENERAC UNITS) LIMITS & REQUIREMENTS OF USE: 1) THE PAD AND THE SUPPORTED EQUIPMENT MUST BE LOCATED AT GROUND LEVEL THIS TABLE DOES NOT APPLY TO ROOFTOP EQUIPMENT, EQUIPMENT LOCATED ON BALCONIES, OR ANY OTHER EQUIPMENT TO BE ELEVATED ABOVE GROUND LEVEL. 2) THE AREA UNDER CONCERETE SLAB ON GROUND SHALL HAVE ALL MATERIALS REMOVED PRIOR TO INSTALLATION ON COMPACTED SOIL AS VERIFIED BY OTHERS. MINIMUM SOIL COEFFICIENT OF FRICTION = 0.25 3) MAXIMUM DIMENSIONS AND WEIGHT OF GENERATORS UNIT SHALL CONFORM TO SPECIFICATIONS STATED HEREIN. PAD WEIGHT TO BE VERIFIED BY OTHERS. 4) ORIGINAL EQUIPMENT MANUFACTURER INSTALLATION INSTRUCTIONS SUPERSEDE HURRICANE PAD INSTALLATION INSTRUCTIONS IF MORE STRINGENT. 5) ELECTRICAL GROUND, WHEN REQUIRED, TO BE DESIGNED & INSTALLED BY OTHERS. ALL MECHANICAL SPECIFICATIONS (CLEAR SPACE, TONNAGE, ETC.) SHALL BE AS PER MANUFACTURER RECOMMENDATIONS AND ARE THE EXPRESS RESPONSIBILITY OF THE CONTRACTOR. 6) ENGINEER SEAL AFFIXED HERETO VALIDATES STRUCTURAL DESIGN AS SHOWN ONLY. USE OF THIS SPECIFICATION BY CONTRACTOR, at. al. INDEMNIFIES & SAVES HARMLESS THIS ENGINEER FOR ALL COST & DAMAGES INCLUDING LEGAL FEES &APPELLATE FEES RESULTING FROM MATERIAL FABRICATION, SYSTEM ERECTION, CONSTRUCTION PRACTICES BEYOND THAT WHICH IS CALLED FOR BY LOCAL, STATE, & FEDERAL CODES & FROM DEVIATIONS OF THIS PLAN. 7) THE ROLE OF THIS ENGINEER FOR THIS PROJECT IS THAT OF SPECIALTY ENGINEER AND NOT THE ENGINEER OF RECORD. CONSEQUENTLY, THE ARCHITECT/ENGINEER OF RECORD SHALL BE RESPONSIBLE FOR THE INTEGRITY OF ALL SUPPORTING SURFACES TO THIS DESIGN WHICH SHALL BE COORDINATED BY THE PERMITTING CONTRACTOR. 8) THIS DOCUMENT IS GENERIC AND DOES NOT PERTAIN TO ANY SPECIFIC PROJECT SITE. 9) THIS ENGINEER SHALL NOT BE HELD RESPONSIBLE OR LIABLE IN ANY WAY FOR ERRONEOUS OR INACCURATE DATA OR MEASUREMENTS. DIMENSIONS ARE SHOWN TO ILLUSTRATE DESIGN FORCES AND OTHER DESIGN CRITERIA. THEY MAY VARY SLIGHTLY, BUT MUST REMAIN WITHIN THE LIMITATIONS SPECIFIED HEREIN. 10) THIS ENGINEER SHALL BE NOTIFIED AND GIVEN AN OPPORTUNITY TO RE-EVALUATE THIS WORK UPON DISCOVERY OF ANY INACCURATE INFORMATION PRIOR TO MODIFICATION OF EXISTING FIELD CONDITIONS AND FABRICATION AND INSTALLATION OF MATERIALS. 11) ALTERATIONS OR ADDITIONS TO THIS DOCUMENT ARE NOT PERMITTED AND INVALIDATE THIS CERTIFICATION. 12) EXCEPT AS EXPRESSLY PROVIDED HEREIN, NO ADDITIONAL CERTIFICATIONS OR AFFIRMATIONS ARE INTENDED. M' 8 �q 13) PADS SHALL BE CONSTRUCTED WITH PRECAST CONCRETE, MINIMUM COMPRESSIVE STRENGTH, fo7,000 PSI AT 28 DAYS. \\ pP-.-Cy �/ 14) ALL OTHER UNITS NOT SHOWN SHALL BE DESIGNED ON A CASE BY CASE BASIS. \ Q�,•�\GENS�•� %' 15) CONTRACTOR SHALL PROVIDE 51W DIA. (0.675"O.DJ GALV. TUBE ASTM A53B SCH 40 MIN. OR 1/2" DIA. SOLID COPPER BAR �•� i SPIKE 4' MIN. EMBED. (SEE MIN. EMBED. AS PER CURRENT ELECTRICAL CODE, BY OTHERS) INTO GROUND THROUGH CONCRETE � , No. 80017 PAD FOR SLIDING RESISTANCE PURPOSE, 12 DIAMETERS EDGE DISTANCE FROM ANY CONCRETE FACE (NOT SHOWN). 16) PADS / UNITS INSTALLED DIRECTLY ON ANY COASTLINE REQUIRE A HEAVIER AND LARGER PAD TO ACCOUNT FOR EXPOSURE DjTable Kz=1.03 �. 28.3.1; ENGINEERING DATA: STATE OF • �� 1)ANALYSES PER 6%EDITION (2017)FLORIDA BUILDING CODE- SECTION 1620 HIGH VELOCITY HURRICANE ZONES. 2)WIND LOADS& LOAD COMBINATIONS PER ASCE7-10 SECTION 2.4.1(LOAD �O�\, R COMBINATIONS), SECTION 29.6& FIGURE 29.5.1 FOR: WIND LOADS ON OTHER STRUCTURES 3)RISK CATEGORY =11 TABLE 1604.5. RISK CATEGORY OF BUILDINGS AND OTHER STRUCTURES, SECTION 301.150E THE MECHANICAL CODE, WIND RESISTANCE, AND 553.844 OF THE FLORIDA STATUTES WIND STORM LOSS MITIGATION. Wind,! 4) WIND LOAD: Wind Speed V = 185 MPH (RISK(RISK CATEGORY 10 F=gz'G-CPAf(Eq. 29.5-2)= 74.63 'At(Ibe) qz-0.00259•Kz-Kzt•Ktl•VA2= 67.03 PSF ...._._...,,.. _.,,..,_,._. ...._ _._. 3JD1-18 Figure 26,8-0 Kzt= 1.00 jDiversiTech Corporabon 7 T T 7FIiING *�I,C Table 26.84 Kd = 0.90 6650 Sugadpal Parkway 9100 RrI11 LA GIN L lr 1 1 Figure 29.6.1 Cf= 1.31 Duluth, GA 30097 Solving Problems to Minimize the Stress or Doing Business I G = 0.85 (800) 397-4823 1 Randall M. a tC 1F telV.E. - 770.713.0823 / 770.7� 13.6464 GE ERAC GE NOW10D 54.3 In. TWIMANCNDRADE: (STY•]) Na- DIA . 5 0Idp. BOLTS. ]- MIN. EDGE DIST.WCE. 13R' EMBED. MTO CONCNETE (RISE PAN MIN. THICKNESS - 08T AND MIN. - BIWIND STRENGTH v B SO) I\-- 7, - AIR COOLED' , UNIT/ EQUIPMENT FG8341.4G PAD USED FOR ALL 185 MPH 0.6(UNIT+ PAD) WEIGHT LBS. RESISTING MOMENT FT-LBS. BESIG CHECK MAXIMUM DIMENSIONS INCHES MINIMUM WEIGHT LBS. MODEL NUMBER (2pc PAD) WEIGHT LBS. PAD WIDTH IN. 2pc PAD LENGTH IN. PAD THICK IN. WIND LOAD LBS. 0.6(WIND MOMENT) FT-LBS. PAGE 1 of i WIDTH LENGTH HEIGHT GENERAC 09kW 25 48 29 340 FG5431-413 275 31.3 54.3 4 721 667 369.0 481 'OK'✓EQ!♦'MP.H1 GENERAC 11kW 25 48 29 348 FG5431-4G 275 31.3 54.3 4 721 667 373.8 487 EORI ROL tMPNI GENERAC 16kW 25 48 29 406 FG5431-4G 275 31.3 54.3 4 721 667 408.6 533 F.ORI ■0* 1MBHIGENERAC 2OkW 25 48 29 448 FG5431-4G 275 31.3 54.3 4 721 667 433.8 566 FORI t01 /MP.HIGENERAC 22kW 25 48 29 466 FG5431-4G 275 31.3 54.3 4 721 667 444.E 580 FOR1 r8r IMPHI