Certification for Design Load Compliance F'�Gc,9oP ' logy
Project Name: Wade Jurney Homes - 1202 eC06-1!%
Project Address: 022LWP004 - 8104 Santa Clara Blvd Ft. Pierce, FL 34951
Permit#: Occupancy Type: Construction Type: MANNED
BY
�t
INSTRUCTIONS FOR USE: St. Lurip r inty
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: Jcornplete all that apply)
1. DESIGN CODE: Florida 2017 Code Sixth Edition with 20 N/A Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open
3. Risk Category:I X II _III_IV Exposure Category:B X C _D
4. Design Wind Velocity 160 mph ASD X LRFD End Zone Width: 3.33 ft
5. Mean Roof Height 11 ft Roof Pitch: 4 :12 Parapet: N/A ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1:+19.3,-30.6 Zone 2: +1 9.3,-53.3 Zone 3: +19.3, 78.9 Zone 4: +33.5,-36.3 Zone 5: +33.5,-48.8 Garage: +31.71-38.6
7. Design Loads: Floor: 40 PSF Roof/Dead: 17 PSF Roof/Live: 20 Balcony: N/A PSF
Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: 50 PSF
8. Were Shear Walls Considered For Structure? Y Yes _Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? Y YesNot Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 2000 PSF Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with tl\�e�apAligijl�,e//Structural portions of the building codes currently adopted and enforced by St. Lucie
County. I ��o\At`Sti$th4 "'tu al elements depicted on these plans provide adequate resistance to the design
forces
is '
W1 Ns1L. \\\\
James G. Friling REV1hW=D r in
Print Name CODE �+��rtyfC�gA� KOF
PE #77824 ST. LU A9,9"NTY
v OCC
Mulhern + Kulp Structural Engineering - 300 Brookside Ave, Ambler, PA 19002
Company Name & Address