HomeMy WebLinkAboutENGINEERING PAPERWORKW !�J6ysj.
UNIVERSAL
ENGINEERING SCIENCES
Consultants In: Geotechnical Engineering • Environmental Sciences
Geophysical Services • Materials Testing • Threshold Inspection
Building Code Administration, Compliance Inspection & Plan Review
820 Brevard Avenue, Rockledge, FL 32955 - P: 321.638.0808 - F: 321.638.0978
IYr a`rroject No.: 0310.1900516.0002
Date Tyg€�ED December 10, 2019
R SCANNED
DEC 12101% BY
artment St. LudeCounty
Permitting D Coimty
St. Lucie
Construction Materials Testing Services
FIELD AND LABORATORY REPORT COVER PAGE
Client: Wade Jurney Homes
3300 Battleground Avenue Suite 101
Greensboro, NC 27410
Project: Lakewood Park - Lot 004 - 8104 Santa Clara Blvd
8104 Santa Clara Blvd. , Ft. Pierce, Indian River County, FL
As requested, Universal Engineering Sciences, Inc. (LIES) representative(s) performed construction materials testing and/or
Feld inspection services on the above project. Testing results and/or inspection observations are reported on the attached
sheets. The contents of this package are summarized below:
Scone of Work
Work Order No.I
Date
I Type of Report
118356-1
1 11/25/2019
In -Place Density Test Report w/Activity Record
118426-1
1 11/26/2019
In -Place Density Test Report w/Activity Record
We hope this information is sufficient for your immediate needs. If you have any questions, please do not hesitate to contact
the undersigned.
Sincerely,
Universal Er
Certificate of
I
r R A' r.
f v V- —
rr,
Richard E. Hoaglin, P.E.
FLORIDA
Professional Engineer No. 48796
This item has been electronically signed and sealed by
Richard E. Hoaglin, P.E. using a Digital Signature. Printed
copies of this document are not considered signed and
sealed and the signature must be verified on any electronic
copies.
ICC Email: JT.Brenner@wadejumeyhomes.00m
UNIVERSAL
ENGINEERING SCIENCES
Consultants In: Geotechnical Engineering • Environmental Sciences
Geophysical Services • Materials Testing • Threshold Inspection
Building Code Administration, Compliance Inspection & Plan Review
UE_ :1,3ject No: 0310.1900516.0002
UES DOCS No:
UES Report No: 118356-1 ARC 112519
On -Site Time (hrs): 0.25
Lab Time (hrs): 0.00
Travel Time (hrs): 0.50
Total Time (hrs): 0.75
820 Brevard Avenue, Rockledge, FL 32955 - P: 321.638.0808 - F: 321.638.0978
Activity Record
Client: Wade Jurney Homes
3300 Battleground Avenue Suite 101
Greensboro, NC 27410
Project: Lakewood Park - Lot 004 - 8104 Santa Clara Blvd
8104 Santa Clara Blvd. , Ft. Pierce, Indian River County, FL
Date of Activity: Monday, 25 November, 2019
Technician: Russell Brause
As requested,, a Universal Engineering Sciences Technician was present at the above referenced project site for the purpose of
earthwork testing for the House pad.
While on site, the technician observed the general condition of the areas to be tested and performed 4 density test(s) for
House pad. All test(s) were performed in accordance with the ASTM D-6938 Nuclear Gauge Method and were found to meet
the project compaction requirements of 95% of the maximum dry density per ASTM D-1557.
As Requested, a Universal Engineering Sciences Technician was present at the above referenced location for the purpose of
picking up proctor sample.
.I
UNIVERSAL UU�S Project No:
ES DOCS No: 0310.1900516.0002
ENGINEERING SCIENCES UES Report No: 118356-1 DT112519
Consultants In: Geotechnical Engineering • Environmental Sciences
Geophysical Services • Materials Testing • Threshold Inspection
Building Code Administration, Compliance Inspection & Plan Review
820 Brevard Avenue, Rockledge, FL 32955- P: 321.638.0808 -F:321.638.0978
In -Place Density Test Report
Client: Wade Jurney Homes
3300 Battleground Avenue Suite 101
Greensboro, NC 27410
Project: Lakewood Park - Lot 004 - 8104 Santa Clara Blvd
8104 Santa Clara Blvd. , Ft. Pierce, Indian River County, FL
Area Tested: House pad.
Type of Test: Field: ASTM D-6938 Nuclear Gauge Method Date of Test: 11/25/2019
Lab: ASTM D1557 Modified Proctor
Technician: Russell Brause
Requirements: 95% of Proctor maximum dry density. These tests apply to the fill and/or surficial soil conditions
only and do not address the condition of the underlvino soils below the tested denths
Test
No.
Location of Test
Range
Depth
(inch)
Proctor
(2)
Field Dry
Density
(PCF)
Field
Moisture
%.
%
Compaction
Comments
(3)
1
NW corner.
0 to -1 ft
12.00
9802
102.6
8.6
96
A
2
NE corner.
0 to -1 it
12.00
9802
102.1
8.2
100
A
3
NE corner.
0 to -1 it
12.00
9802
101.7
10.1
95
A
4
SW comer.
0 to -1 ft
12.00
9802
102.1
7.4
95
A
(1) Ref. Datum: 0 = Top of Native
(2)
Maximum
Optimum
Proctor
Dry
Moisture
#
Density
Content
9802 .
107.0
12.0
This test was performed without deviation from ASTM procedures.
(3) Comments Key
A. Compaction meets min. requirements
B. Compaction does not meet min. requirements
C. Moisture does not meet requirements
D. Recompaction required
E. Recompacted, Retested, Meets Requirements
This report shall not be reproduced, except in lull, without the written approval or Universal Engineering Sciences.
LIE -» ,roject No:
0310.1900516.0002
k-IN'
A'
-
UES Report No:
118426-1 ARC 112619
ENGINEERING SCIENCES
Consultants In: Geotechnical Engineering • Environmental Sciences
On -Site Time (hrs): 0.50
Lab Time (hrs): 0.00
Geophysical Services • Materials Testing • Threshold Inspection
Travel Time (hrs): 1.25
Building Code Administration, Compliance Inspection & Plan Review
Total Time (hrs): 1.75
820 Brevard Avenue, Rockledge, FL 32955 - P: 321.638.0808 - F: 321.638.0978
Activity Record
Client: Wade Jurney Homes
3300 Battleground Avenue Suite 101
Greensboro, NC 27410
Project: Lakewood Park - Lot 004 - 8104 Santa Clara Blvd
8104 Santa Clara Blvd. , Ft. Pierce, Indian River County, FL
Date of Activity: Tuesday, 26 November, 2019
Technician: Russell Brause
As requested, a Universal Engineering Sciences Technician was present at the above referenced project site for the purpose of
earthwork testing for the House pad.
While on site, the technician observed the general condition of the areas to be tested and performed 4 density test(s) for
House pad. All test(s) were performed in accordance with the ASTM D-6938 Nuclear Gauge Method and were found to meet
the project compaction requirements of 95% of the maximum dry density per ASTM D-1557.
The Contractor was notified of the test results or a copy was left for their records.
UN1V°ERSAL
ENGINEERING SCIENCES
Consultants In: Geotechnical Engineering • Environmental Sciences
Geophysical Services • Materials Testing • Threshold Inspection
Building Code Administration, Compliance Inspection & Plan Review
820 Brevard Avenue, Rockledge, FL 32955 - P: 321.638.0808 - F: 321.638.0978
In -Place Density Test Report
UES Project No: 0310.1900516.0002
UES DOCS No:
UES Report No: 118426-1 DT 112719
Client: — _Wade Jurney Homes
3300 Battleground Avenue Suite 101
Greensboro, NC 27410
Project: Lakewood Park - Lot 004 - 8104 Santa Clara Blvd
8104 Santa Clara Blvd. , Ft. Pierce, Indian River County, FL
Area Tested: House pad.
Type of Test: Field: ASTM D-6938 Nuclear Gauge Method Date of Test: 11/27/2019
Lab: ASTM D1557 Modified Proctor
Technician: Russell Brause
Requirements: 95% of Proctor maximum dry density. These tests apply to the fill and/or surficial soil conditions
only and do not address the condition of the underlvina soils below the tested depths.
Test
No.
Location of Test
Range
Depth
(inch)
Proctor
(2)
Field Dry
Density
(PCF)
Field
Moisture
%
%
Compaction
Comments
(3)
1
NW corner.
0 to -1 ft
12.00
9804
111.3
11.9
99
A
2
NE corner.
0 to 4 ft
12.00
9804
114.3
10.9
102
A
3
SE corner.
0 to -1 ft
12.00
9804
114.1
10.0
102
A
4
SW comer.
0 to -1 ft
12.00
9804
113.4
10.8
101
A
(1) Ref. Datum: 0 = Top of Final Grade
(2)
Maximum
Optimum
Proctor
Dry
Moisture
#
Density
Content
9804
112.0
11.0
This test was performed without deviation from ASTM procedures.
(3) Comments Key
A. Compaction meets min. requirements
B. Compaction does not meet min. requirements
C. Moisture does not meet requirements
D. Recompaction required
E. Recompacted, Retested, Meets Requirements
This report shall not be reproduced, except in full, without the written approval of Universal Engineering Sciences.