Loading...
HomeMy WebLinkAboutENGINEERING PAPERWORK`4. ENGINEERING & TESTING, INC. RECEIVED Phone: (866) 781-6889 •Fax: (866) 784-8550 www.flotidaengineeringandtesting.com 250 S.W.13'" Avenue J U N 2 0 2019 Pompano Beach, FL 33069 $T. Lucie County, Permit n DATE: 6/17/19 $ ER #: 19-2996 SCANNED CLIENT: All Area Roofing BY ADDRESS: 3921 S. US Highway 1 Fort Pierce, FL 34982 Lucie County PROJECT: Franklin Residence Flat Wood Non -Insulated Roof Deck ADDRESS: 400 E. Weatherbee Road Fort Pierce, FL 2017 FBC/ASCE-7 DESIGN PRESSURE CALCULATIONS Proiect Information: Height = 8' Exposure: C Basic/Ultimate Wind Speed: V i=163 mph Length = 37' Category: II Nominal Wind Speed: V.d=V it*40.6 Width = 15' Slope: < 7° (asd = allowable strength design) Parapet Wall: N/A Residential KZ = 0.85, Kzt = 1.0, Kd = 0.85 Design Calculations: Velocity Pressure: q = 0.00256*K K tKdV2 Velocity Pressure (u): q=0.00256(0.85)(1.0)(0.85)(163)2 = 49.14 psf Velocity Pressure (.d): q=0.00256(0.85)(1.0)(0.85)(163*40.6)2 = 29.49 psf Width of Pressure Coefficient: 0.1(15') = 1.5' 0.4(8') = 3.2' ) use: TO" Effective Wind Area: <1 Off For parapet height three feet (3') or larger, zone three (3) shall be treated as zone two (2). External Pressure Coefficient: 1) GCP1 = -1.0 2) GCP2 = -1.8 3) GCP3 = -2.8 Internal Pressure Coefficient: 1) GCP; = 0.18 REVIEWED FOR CODE COMPLIANCE ST. L.UCIE COUNTY BOCC re, `:% v Q ti Qaawy ��\ t1 &.4ssarance GL r4d Page 2, 6/17/19, Job Order #19-2996 All Area Roofing - Franklin Residence Flat Wood Non Insulated Roof Deck 400 E. Weatherbee Road; Fort Pierce, FL: Design Pressures Based on Vasd: 1) Field 2) Perimeter 3) Corners Attachment Requirements: P1 = 29.49*[(-1.0) — (0.18)] = -34.8 psf P2 = 29.49*[(-1.8) — (0.18)] = -58.4 psf P3 = 29.49* [(-2.8) — (0.18)] = -87.9 psf The system is acceptable as approved based on the requirements of Florida Product Approval # FL1654-R23, Appendix 1, page 26 of 65, System No. W-170 with a maximum design pressure of -90 psf. Base Ply: Self adhere one or more plies of Elastoflex SA V Base Ply sheet to the min. 15/32" plywood deck. Cap Ply: Torch apply the Polyflex G Cap Ply sheet to the base ply sheet. Notes: Corners and perimeter area dimension shall not be less than a = 3'0" Contractor to verify that the fastening patterns meet manufacturer's requirements for issuance of a warranty (as applicable). All work shall be in compliance with the local building code product control notice of acceptance and manufacturer specifications and Florida Building Code 2017 Edition. Wind load calculations based on ASCE-7, FBC 2017, and information provided by client. Client is responsible for verifying existing/proposed conditions/decks as it pertains to the above provided product approval. All work shall be inspected by our field engineer (or authorized representative) or a building department inspector to verify compliance with specifications. Sincerely, Mark A. Mesian Florida Engineer Florida Reg. No. Certificate of Au AN MF ,*,,,, �ENSF S/920: 5 48202 rAgTE OF c �,