Loading...
HomeMy WebLinkAboutREVISONS - BUILDING PERMITOFFICE USE ONLY: DATE FILED: REVISION FEE: 1 �o • �J PERMIT # O �� RECEIPT # 5 PLANNING & DEVELOPMENT SER CE R� IE EV D BUILDING &CODE REGULATION DIMS ON 2300VIRGINIAAVENUE JUN 2 9 2020 FORT PIERCE, FL 34962-5652 (772) 462.1553 LST. Lucie County, Pem, APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION LOCATION/SITE ISCBNY E® ADDRESS: (cva Lj j, f)� St. LucieCounfv DETAILED DESCRIPTION OF PROJECT REVISIONS: CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: BUSINESS NAME: G .fic HLIA QUALIFIERS NAME: k ¢ a"^ ADDRE S• 2�3 5u� OP br CITY: �— STATE: PL PHONE (DAYTIME): 77% - 3 0—[atk OWNER/BUILDER INFORMATION: CITY: PHONE (DAYTIME: STATE: ARCHITECT/ENGINEER INFORMATION: NAME: _ ADDRESS: CITY: PHONE (DAYTIME): STATE: ST. F. FAX: FAX: CO CERT. #: 3 oo S-f ZIP: wo ZIP: SLCCC: 9/23/09 &106 Revised 06/30/17 l l®t.1loG COpl FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residen I jai PeFRTC-iMT-thz) Project Name: DINOLARESIDENCE Builder Name: JUN p 9 2020 Street: 6000 HICKORY DRIVE Permit Office: STLUCIECOU TY City, State, Zip: FORT PIERCE, FL, 34982 Permit Number: ST. Lucie County, Permitting Owner: Jurisdiction: ST LUCIE COU Design Location: FL, Fort Pierce County. St. Lucie (Flonda Climate Zone 2 ) 1. New construction a existing New (From Plans) 9. Wall Types (3431.2 scift.) Insulation Area 2. Single family or multiple family single-family a. Concrete Block- Int lnsul, Exterior R=5.0 2656.50 ft= b. Frame - W ood, Exterior R=24.5 336.00 W 3. Number of units, if multiple family 1 c. Frame - Wood, Adjacent R=11.0 224.00 fF 4. Number of Bedrooms 5 d. other (see details) R= 214.67IF 5. Is this aworst case? No 10. Ceiling Types (3877.0 sqh.) Insulation Area a Roof Deck (Unvented) R=20.0 3379.00 ft2 6. Condtioned floor area above grade (fr-) 3379 b. Knee Wall (Unvented) R=19.0 498.00 ft' Conditioned floor area below grade(ft7 0 c. N/A R= fM 11. Ducts R fr 7. W indo (451.0 sgft.) Description Area a Sup: Attic, Rat: Attic, AH: Garage 6 250 a. U-Factor: Sgt. U=0.35 216.00IF b. Sup: Attic, Ret: Attic, AH: Garage 6 125 SHGC: SHGC�0.20 b. U-Factor. Sgl, U=O.32 192.00 ft= 12. Coding systems kBtu)hr Efficiency SHGC: SHGC=0.19 a Central Unit - 59.5 SEER:16.50 c. U-Factor: Sgl, U�.29 40.00 fr- b. Central Unit 24.0 SEER:16.00 SHGC: SHGC=0.21 13. Heating systems kBtu/hr Efficiency d. U-Factor. other (see details) 3.00 fr- a. Electric Strip Heat 34.0 COPA.00 SHGC: other (see details) b. Electric Strip Heat 17.0 COP:1.00 Area Weighted Average Overhang Depth: 1.600 ft. Area Weighted Average SHGC: 0.197 14. Hot water systems S. Floor Types (3379.0 sgft.) Insulation Area a Natural Gas Tankless Cap: 1 gallons a. SlatrOrr-Grade Edge Insulation R=0.0 3379.00 ft-- b. Conservationleatures EF: 0.800 b. N/A R= ft- None c. N/A R= fC 15. Credits None Glass/Floor Area: 0.133 Total Proposed Modified Loads: 106.81 PASS Total Baseline Loads: 110.78 I hereby certify that the plans and specifications covered by Review of the plans and �g'C71t; STq , this calculation are in compliance with the Florida Energy specifications covered by this zO Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: 6-18-2020 this building will be inspected for compliance with Section 553.908 0 I hereby certify that th0g,asd,isincompliance Florida Statutes.with the Florida Energ t''Oplygr{4u OWNER/AG NT• BUILDING OFFICIAL: DATE: to, DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed In accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50' (R402.4.1.2). 6/18/2020 12:57 PM EnergyGauge® USA 6.0.02 (Rev. 1)-FlaRes2017 FBC 6th Edition (2017) ��/ s o� Compliant Software t'�g91-of 8 F�ti� FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: DINOLA RESIDENCE Bedrooms: 5 Address Type: Street Address Building Type: User Conditioned Area: 3379 Lot# Owner Name: Total Stories: 1 _ Block/Suhdivlsion: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street 6000 HICKORY DRIVE Permit Office: ST LUCIE COUNTY Cross Ventilation: No County St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Single-family FL, 34982 New/Epsting New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO BEACH MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 AHU 1 2344 29764 2 AHU 2 1035 9625.5 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 MSAFE 22 204.6 No 0 1 Yes Yes Yes 2 M W IC 103 957.9 No 0 1 No Yes Yes 3 M TOILET 19 176.7 No 0 1 No Yes Yes 4 M BATH 156 1450.8 No 0 1 Yes Yes Yes 5 BEDROOM 3 198 1841.4 No 0 1 1 Yes Yes Yes 6 WIC 3 52 483.6 No 0 1 Yes Yes Yes 7 FOYER 209 1943.7 No 0 1 Yes Yes Yes 8 WIC 2 52 483.6 No 0 1 Yes Yes Yes 9 BEDROOM 2 188 1748.4 No 0 1 1 Yes Yes Yes 10 PANTRY 36 334.8 No 0 1 No Yes Yes 11 GREAT ROOM 524 12838 No 0 - 1 Yes Yes Yes 12 KITCHEN 174 1618.2 Yes 0 1 No Yes Yes 13 BATH 2 104 967.2 No 0 1 No Yes Yes 14 DINING 240 2232 No 0 1 Yes Yes Yes 15 MASTER BEDROO 267 2483.1 No 0 1 1 Yes Yes Yes 16 KITCHEN 2 195 1813.5 Yes 0 1 Yes Yes Yes 17 LIVING 242 2250.6 No 0 1 Yes Yes Yes 18 WIC 5 48 446.4 No 0 1 Yes Yes Yes 19 BATH 3 56 520.8 No 0 1 No Yes Yes 20 BEDROOM 5 192 1785.6 No 0 1 1 Yes Yes Yes 21 BEDROOM 4 132 1227.6 No 0 1 1 Yes Yes Yes 6118/202012:57 PM EnergyGaugeS USA 6.0.02 (Rev. 1) - FlaRes2017 FSC 6th Edition (2017) Compliant Software Page 2 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 22 HALL 20 186 No 0 1 No Yes Yes 23 CLST 4 12 111.6 No 0 1 Yes Yes Yes 24 LAUNDRY 138 1283A No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On Grade Edge Insulation M SAFE 6 ft 0 ?2 IF ___ 1 0 0 2 Slab -On -Grade Edge Insulation M W IC 1 ft 0 103 ft- ___ 1 0 0 3SIab-On-Grade Edge Insulatim M TOILET 1 ft 0 19 ft= ____ 1 0 0 tSlab-O -Grade Edge Insulatim M BATH 13 ft 0 156 ft. ____ 1 0 0 5 Slab -On Grade Edge Insulatim BEDROOM 3 28 It 0 198 ft= ____ 1 0 0 6Slab-On-Grade Edge Insulation WIC 3 8ft 0 52 W ____ 1 0 0 7 Slab -On -Grade Edge Insulatim FOYER 11 ft 0 209 fr- ___ 1 0 0 BSIab-On-Grade Edge Insulatim WIC 2 8ft 0 52 W __ 1 0 0 9 Slab-Oo-Orade Edge Insulatim BEDROOM 2 21 ft 0 188 fr _- 1 0 0 1031ab-On-Grade Edge Insulatim PANTRY 1ft 0 36 ft2 -_ 1 0 0 11SIab-On-Grode Edge Insulatim GREAT ROOM 17ft 0 524W ___ 1 0 0 12SIab-On-Grade Edge Insulatim KITCHEN 1 ft 0 174 ft- ____ 1 0 0 13SIab-On-Grade Edge Insulatim BATH 2 1 ft 0 104 ft- __ 1 0 0 14SIab-Cr Grade Edge Insulatim DINING 16 It 0 240 ft- -_ 1 0 0 153Iab-Orl,Grade Edge Insulatim MASTER BEDRO 34 ft 0 267 ft= ___ 1 0 0 16SIat>Oo-Grade Edge Insulatim KITCHEN 2 15 ft 0 195 ft- ___ 1 0 0 17SIab-On-Grade Edge Insulatim LIVING 13ft - 0 242 ft- ___ 1 0 0 18SIab-On-Grade Edge Insulatim WIC 5 8ft 0 48 ft-7 ___ 1 0 0 1931ab-Oo-Grade Edge Insulatim BATHS 1ft 0 56 ft- __ 1 0 0 206Iab-On Grade Edge Insulatim BEDROOM 5 28 it 0 192 ft- __ 1 0 0 21SIab-On-Grade Edge Insulatim BEDROOM 4 23 It 0 132 W _- 1 0 0 22SIab-On-Grade Edge Insulatim HALL 1 ft 0 20 If _- 1 0 0 23SIab-Oo-Grada Edge Insulatim CLST 4 2 ft 0 12 ft- ___ 1 0 0 24Slab-O -Grade Edge Insulatim LAUNDRY Eft 0 13SW __ 1 0 0 6/181202012:57 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Ecitim(2017) Compliant Software Page of FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT ROOF V # Type Roof Gable Materials Area Area Roof Color Rod Barr Solar SA Emilt Absor. Tested Emitt Deck Pitch Tested Insul. (deg) 1 Hip Metal 3660 ft- Oft= Light N 0.6 No 0.9 No 20 22.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unwanted 0 3379 ft2 N N 6118/202012:57 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edtion (2017) Compliant Software Page 4 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) M SAFE 0 Blown 22IS 0.1 Wood 2 Under Attic (Unvented) M W IC 0 Blown 103 ft- 0.1 Wood 3 Under Attic (Unvented) M TOILET 0 Blown 19 ft- 0.1 Wood 4 Under Attic (Unvented) M BATH 0 Blown 156 W 0.1 Wood 5 Under Attic(Unvented) BEDROOM 0 Blown 198 fr 0.1 Wood 6 Under Attic Unvented) WIC3 0 Blown 52 ft- 0.1 Wood _ 7 Under Attic (Unvented) FOYER 0 Blown 209 IF 0A Wood _ 8 Under Attic (Unvented) WIC 0 shun 52 ft2 0.1 Wood _ 9 Under Attic(Unvented) BEDROOM 0 Blown 188 ftz 0.1 Wood _ 10 Under Attic (Unvented) PANTRY 0 Blown 36 ft- 0.1 Wood 71 Under Attic (Unvented) GREAT ROOM 0 Blown 524 ft- 0.1 Wood 12 Under Attic, (Unvented) KITCHEN 0 Blown 174 ft-' 0.1 Wood _ 13 Under Attic(Unvented) BATH 0 Blown 104 ft- 0.1 Wood _ 14 Under Attic (Unvented) DINING 0 Blown 240 fr 0.1 Wood 15 Under Attic (Unvented) MASTER BEDRO 0 Blown 257 fr 0.1 Wood 16 Under Attic (Unvented) KITCHEN2 0 Blown 195 ft- 0.1 Wood 17 Under Attic(Umented) LIVING 0 Blown 242 ft- 0.1 Wood _ 18 Under Attic (Unvented) W IC S 0 Blown 48IF 0.1 Wood 19 Under Attic (Unvented) BATH 0 Blown 56 fF 0.1 Wood 20 Under Attic (Unvented) BEDROOMS 0 Blown 192 ft- 0.1 Wood _ 21 Under Attic (Unvented) BEDROOM4 0 Bloom 132 ft- 0.1 Wood 22 Under Attic (Unvented) HALL 0 Blown - 20 fr 0.1 Wood _ 23 Under Attic (Unvented) CLST4 0 Blown 12 ft- 0.1 Wood 24 Under Attic (Unvented) LAUNDRY 0 Blom 138 ft. 0.1 Wood 25 Knee Wall (Unvented) BEDROOM 2 19 Blown 63 IF 0.1 Wood _ 26 Knee Wall (Unvented) WIC 2 19 Blown 12 ft- 0.1 Wood 27 Knee Wall (Unvented) WIC 2 19 Blown 12 IF 0.1 Wood 28 Knee Wall (Unvented) FOYER 19 Blown _ 33 fr- 0.1 Wood 29 Knee Wall (Unvented) WIC 3 19 Blown 12 ft- 0.1 Wood 30 Knee Wall (Unvented) WIC 3 19 Blown 12 ft- 0.1 Wood _ 31 Knee Wall (Unvented) BEDROOM 3 19 Blown 45 ft- 0.1 Wand 32 Knee Wall(Unvented) MASTER BEDRO 19 Bla 51 ft- 0.1 Wood 33 Knee Wall(Unvented) GREAT ROOM 19 Blown 51 ft- 0.1 Wood 34 Knee W NI (Unvented) DINING 19 Blow _ 48 W 0.1 Wood 35 Knee Wall (Unvented) WINO 19 Blown 36 IF 0.1 Wood _ 36 Knee W dl (Unvented) BATH 2 19 Blain 27 fF 0.1 Wood 37 Knee Wall (Unvented) KITCHEN 19 Blown 27 fir 0.1 Wood 38 Knee Well (Unvented) LAUNDRY 19 Blown 69 fr 0.1 Wood 6118/202012:57 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Froming Solar Below 1 N Exerior Concrete Block - Int Insul M SAFE 5 6 0 9 4 56.0 W 0 0 0.6 0 _ 2 N Exterior Concrete Block - Int Insul M BATH 5 13 0 9 4 121.3 ft-- 0 0 0.6 0 3 N E#aior Concrete Block- Int lnstEEDROOM 3 5 12 0 9 4 112.Oft- 0 0 0.6 0 4 W Exterior Concrete Block- Int InstBEDROOM 3 5 16 0 9 4 149.3 ft-- 0 0 0.6 0 _ 5 S Exterior Concrete Black -Int Insul WIC3 5 4 0 9 4 37.3 ft2 0 0 0.6 0 _ 6 W Exterior Concrete Block - Int Insul WIC 3 5 4 0 9 4 37.3 ft- 0 0 0.6 0 _ 7 W E)dericr Concrete Block- Int Insul FOYER 5 11 0 9 4 102.7 ft- 0 0 0.6 0 8 N Enteric Concrete Block- Int Insul WIC 2 5 4 0 9 4 37.3 fF 0 0 0.6 0 9 W Exterior Concrete Block- Int Insul WIC 2 5 4 0 9 4 37.3 fF 0 0 0.6 0 10 S Exterior Concrete Block- Int InsiBEDROOM 2 5 6 0 9 4 66.0 it-, 0 0 0.6 0 11 W Exterior Concrete Block- Int Ins BEDROOM 2 5 15 0 9 4 140.0 ft' 0 0 0.6 0 12 S Garage Frame -Wood BEDROOM 11 6 0 9 4' 56.0 IF 0 0.1 0.6 0 _ 13 E Exterior Concrete Block- Int Insu➢REAT ROO 5 17 0 24 6 416.5IF 0 0 0.6 0 14 S Garage Frame -Wood KITCHEN 11 9 0 9 4 84.0 ft-' 0 0.1 O.6 0 15 S Garage Frame -Wood BATH 11 9 0 9 4 84.0 ft= 0 0.1 0.6 0 16 E F)derior Concrete Block -Int Insul DINING 5 16 0 9 4 149.3 ft= 0 0 0.6 0 17 N Exterior Concrete Block- Int InsuMASTER BE 5 17 0 9 4 158.7 ft= 0 0 0.6 0 18 E Exterior Concrete Block- Int InsuMASTER BE 5 17 0 9 4� 158.7 IF 0 0 0.6 0 19 S Exterior Concrete Block- Int lnsulKITCHEN 2 5 15 0 9 4 140.0 fF 0 0 0.6 0 _ 20 N Exterior Concrete Block - Int Insul LIVING 5 13 0 9 4 121.3 fr 0 0 0.6 0 21 S Exterior Concrete Block - Int Insul WIC 5 5 8 0 9 4 74.7 it- 0 0 0.6 0 22 E Exterior Concrete Block- Int InsuBEDROOM 5 5 12 0 9 4 112.011T 0 0 0.6 0 _ 23 S bderior Concrete Block- Int InsuBEDROOM 5 5 16 0 9 4 149.3 it-' 0 0 0.6 0 24 N Exterior Concrete Block - Int InskBEDROOM 4 5 12 0 9 4. 112.0 ft= 0 0 0.6 0 _ 25 E Exterior Concrete Block- Int InsuBEDROOM 4 5 11 0 9 4 102.7 W 0 0 0.6 0 26 N Exterior Concrete Block- Int Insul CLST 4 5 2 0 9 4 18.7 IF 0 0 0.6 0 27 S Exterior Concrete Block- Int Insul LAUNDRY 5 6 0 9 4 56.0 fF 0 0 0.6 0 28 W Garage Frame -Wood LAUNDRY 19 23 0 9 4 214.7W 0 0.1 0.6 0 29 E Exterior Frame -Wood GREAT ROO 24.5 14 0 4 0 56.0 ft2 0 0A 0.6 0 _ 30 S Extericr Frame- Wood GREAT ROO 24.5 28 0 4 0 112.0 ft- 0 0.1 0.6 0 31 W Exterior Frame -Wood GREAT ROO 24.5 14 0 4 0 56.0 ft2 0 0.1 0.6 0 32 N 6derior Frame -Wood GREAT ROO 24.6 28 0 4 0 112.0ft-' 0 0.1 0.6 0 WINDOWS Orientation shown is the entered, Proposeclortentation. well Overhang v/ ft Omt ID Frame Penes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening _ 1 N 2 Vinyl Low-E Single Yes 0.29 0.23 Y 3.0 IF' 1 ft 6 in 1 ft4 in None None _ 2 W 4 Vinyl Low-E Single Yes 0.32 0.19 Y 36.0 fC- 1 ft 6 in 1 ft 4 in None None _ 3 W 7 Vinyl Low-E Single Yes 0.35 0.2 Y 16.0 ft= 1 ft 6 in 1 ft 4 in None None _ 4 W 7 Vinyl Low-E Single Yes 0.35 0.2 Y 16.0IF i ft 6 in 1 ft 4 in None None 5 W 7 Vinyl Low-E Single Yes 0.35 0.2 Y 48.0IF 1 ft 6 in 1 ft 4 in None None _ 6 W 11 Vinyl Low-E Single Yes 0.32 0.19 Y 36.0 f - 1 ft 6 in 1 ft 4 in None None 7 E 13 Vinyl Low-E Single Yes 0.35 0.2 Y 96.0 ft- 1 ft 6 in 1 ft 4 in Drapes blinds None 6118/202012:57 PM EnergyGougeO USA 6.0.02 (Rev. 1) - F1aRes2017 FBC 6th Eddion (2017) Compliant Software Page 6 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WINDOWS Orientation shown is the entered, Proposed orientation. V # Wall Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 8 _ 9 10 11 12 _ 13 _ 14 15 E 16 Vinyl E 18 Vinyl S 19 Vinyl N 20 Vinyl E 22 Vinyl N 24 Vinyl E 29 Vinyl W 31 Vinyl Low-E Single Low-E Single Low-E Singe Lav-E Single Lov-E Singe -o E Singe Low-E Singe Low-E Singe Yes Yes Yes Yes Yes Yes Yes Yes 0.32 0.19 Y 36.0 ft- 1 ft 6 in 1 ft 4 in 0.32 0.19 Y 36.6 ft= 1 ft 6 in 1 ft 4 in 0.32 0.19 Y 6.0 ft- 1 it 6 in 1 It 4 in 0.35 0.2 Y 40.0 it- 1 it 6 in 1 ft 4 in 0.32 0.19 Y 18.0 W 1 It 6 in 1 ft 4 in 0.32 0.19 Y 24.0 fr 1 It 6 in 1 ft 4 in 0.29 0.21 Y 20.0 ft- 1 It 6 in 1 ft 4 in 0.29 0.21 Y 20.0 fr- 1 It 6 in 1 ft 4 in None None None None None None Drapes/blinds Drapes/blinds None None None None None None None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 652 fF 552 ft-' 47 It 9ft 19 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Whdehouse Proposed ACH(50) .000518 4595.4 252.28 474.46 .2089 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 2 Electric Ship Heat/ Electric Strip Heat/ None None C0P:1 34 kBtu/hr COPA 17 kBtu/hr 1 2 sys#1 sys#2 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flaw SHR Block Ducts 1 2 Central Unit/ Central Unit/ Split Split Single SEER: 16.5 59.5-kBtu/hr 1785 elm Single SEER: 16 24 kBtu/hr 720 cfm 0.8 1 0.8 2 sys#1 sys#2 HOT WATER SYSTEM If System Type SubType Location EF Cap Use SetPnt Conse tics 1 2 Natural Gas Natural Gas Tankless Tankless LAUNDRY LAUNDRY 0.8 1 gal 55.1 gal 120 dog 0.8 1 gal 55.1 gal 120 deg None None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft= 6118/202012:57 PM EnergyGauge® USA 6.0.02 (Rev. 1)- FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 8 a W J Y W /2 V a D N IL z ❑O❑ N mmn mn H H �- 2 mn m� zzz �WccWo �WccWo O 57 m N 0 O CC N w V O ¢= Z Wci " Oa� O ❑ q o w oz o: >Z ° a ° <3 _3z ° 8 m am Q q Q Y LL O 0 ❑ ❑ m Om mr OW wr mm ww mm ww 000 N~ 9 mwo Al. X`. U O ❑ ❑ m �n �� stow Wm eDfWD CC O U d 0 q0 mom W m M M M M M M M M M M M M M M M M M M m M M M M q aQQ m 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 arDnrl mm N ow tow ? LL a 7JJ = mm rr mm rr m �m wm cow F U) X: J J LU LU N F J a -�-�� nn nr ww ww N z r� r r � c U ❑❑ 6 0� .c .z .r .r_ .z .K .z .� r r t s s c G d 6 �W W LL nWW ww ww m m qqQ � 0 m U 8 Q Q <<< J N �(O mm (WO(WO tm0 (WO owo �2 Q l9 tm1 p {�ILLL N0- Z QLL0_d y 8 S -8 2 8 13 8 B B I4 m_ m_ m_ m W m W W W W co m W m m W � W W m m W m W m 0 `m `m ❑ ❑ 0 ❑ 0 ❑ ❑ ❑ ❑ ❑ 0 ❑ 0 0 ❑ ❑ ❑ ❑ 0 ❑ ❑ ❑ ❑ 0 ❑ i It U2> 8 8 8 g N a N 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARP 2 9 2020 ESTIMATED ENERGY PERFORMANCE INDEX' = 6 The lower the Energy Performance Index, the more efficient he Lucle County, Permitting 1. New home or, addition 1. New (ELom. Plans) 12. Ducts, location & insulation level a) Supply ducts R_ e Q 2. Single-family or multiple -family 2. _$irLglg-family b) Return ducts R__-C,Q c) AHU location Garage 3. No. of units (if multiple -family) 3. ____1_ - 4. Number of bedrooms 4. ____5 13. Cooling system: Capacity_ @$,6 a) Split system SEER vaarrie 5. Is this a worst case? (yes/no) 5. __No b) Single package SEER c) Ground/water source SEER/COP__ 6. Conditioned floor area (sq. ft.) 6. _ 3379 d) Room unit/PTAC EER e) Other _ 7. Windows, type and area a) U-factor:(weighted average) 7a.__Q LSP b) Solar Heat Gain Coefficient (SHGC) 7b. 0 W 14. Heating system: Capacity U&I c) Area 7c._451 0 a) Split system heat pump HSPF b) Single package heat pump HSPF__ 8. Skylights c) Electric resistance COP_ 1.0 a) U-factor:(weighted average) 8a.___ NNA d) Gas furnace, natural gas AFUE_ b) Solar Heat Gain Coefficient (SHGC) 8b._ IJ�A e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 90. a) Electric resistance EF__ b) Gas fired, natural gas EF_ 0,80 10. Wall type and insulation: c) Gas fired, LPG EF__ A. Exterior: d) Solar system with tank EF__ 1. Wood frame (Insulation R-value) 10A1._ 24,5 e) Dedicated heat pump with tank EF__ 2. Masonry (Insulation R-value) 10A2. 5.0 f) Heat recovery unit HeatRec96 B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B7. vffLes _ 2. Masonry (Insulation R-value) 10B2._ 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a._0 0 b) Cross ventilation _mil 4 b) Single assembly 11b. c) Whole house fan Ng c) Knee walls/skylight walls 11c._ 19 2 d) Multizone cooling credit d) Radiant barrier installed 11d.__.Lo e) Multizone heating credit f) Programmable thermostat _-- N *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be'nstalled (or ex ded) in this home before final inspection. Otherwise, a new EPL display card will be comple d based n'nst ed code compliant features. LZO 10 Builder Signature: Dale:7' Address of New Home:k 6000 IQSORY DRIVE__ __ City/FL Zip: EORTT J.ER(/n FL ---__ 6/18/2020 12:67-34 PM EnergyQwge®USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) j 1 of 1 Okla rib Project Summary SCANNED Job: 1 wrightsoft' Byte: JUNEt8,2020 AHU 1 BY QUICK CALCS, INC. stlucIecounfv 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Pme: 772-466-6799 Fax T72-4666796 Email: OUICKCALCSCAOLCOM For: DiNOLARESIDENCE 6000 HICKORY DRIVE, FORT PIERCE, FL3498 JUIN 2 9 M20 Notes: ST. Lucie County, Perri Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside cb 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range Relative humidity M 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 22757 Btuh Structure 29789 Btuh Ducts 10364 Btuh Ducts 14781 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh none e) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 33122 Btuh Use manufacturer's data IT Rate/swing multiplier 0.95 Infiltration Equipment sensible load 42342 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 5837 Btuh Ducts 4090 Btuh Central vent (0 cfm) 0 Btuh Heatingg Coolingg MR (none) Area (ft2) 2M Equipment latent load 9927 Btuh Volume (ft3) 33415 33415 Air charges/hour 0.27 0.14 Equipment Total Load (Sen+Lat) 52269 Btuh Equiv.AVF (cfm) 149 80 Req. total capacity at 0.70 SHR 5.0 ton Heating Equipment Summary Cooling Equipment Summary Make Make Chamin'on Trade Trade CHAMPION HEATING AND COOLING Model Cond AL19136021 AHRI ref Coil AE60DBC21 AHRI ref 205572325 Efficiency 10D EFF Efficiency 13.0 EER, 16.5 SEER Heating input 7.6 kW Sensible cooling 41650 Btuh Heating output 25848 Btuh Latent coaling 17850 Btuh Temperature rise 12 OF Total cooling 59500 Btuh Actual air flow 1983 cfm Actual air flow 1983 cfm Air flow factor 0.060 cfm/Btuh Airflow factor 0.044 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.82 Calculations approved by ACCA to meet all RighFSuiIe9UniwrsaI2019 1Aivrse1208 RSU98101 ...\Wrightsofl HACDINOtA REVISIONS 6 18 20.mp CeIc =MJ6 Front Door Paws: W of Manual jV ¢-- ■ ILE Copy op 11:64: 17 Page 1 Project SummaryJob: wrightsoft• AHU 2 Date: JUNE 18, 2020 QUICK CALCS, INC. 317 ST LUCIE WE, FORT PIERCE, FL 34946 Phone: 772-488-8799 Fax 772-466-6796 Email: OUICKCALCS®AOL.COM Proiect Information — For: DiNOLA RESIDENCE 6000 HICKORY DRME, FORT PIERCE, FL34982 Notes: Design Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside do 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TO 28 OF Design TD 15 OF Daily ranggee Relative humidty M 50 Moisture dfference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 10056 Btuh Structure 13551 Btuh Ducts 2776 Btuh Ducts 4045 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 12833 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 16717 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure - 3558 Btuh Ducts 1072 Btuh Central vent (0 cfm) 0 Btuh Heatingg Coolingg (none) Area (ft2) 1035 1A Equipment latent load 4630 Btuh Volume (ft3) 9626 9626 Air charges7hour 0.32 0.17 Equipment Total Load (Sen+Lat) 21347 Btuh Equiv. AVF (cfm) 52 28 Req. total capacity at 0.70 SHR 2.0 ton Heating Equipment Summary Cooling Equipment Summary Make Make Chain plan Trade Trade CHAMPION HEATING AND COOLING Model Cond TC482422 AHRlref Coil AE24BX21++TXV AHRlref 202323783 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 3.4 kW Sensible cooling 16800 Btuh Heating output 11610 Btuh Latent cooling 7200 Btuh Temperature rise 13 OF Total cooling 24000 Btuh Actual air flow 800 cfm Actual air flow 800 cfm Air flow factor 0.062 cfm/Btuh Air flaw factor 0.045 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.79 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -7#F wr19ti=+o6ft� 2020- n-1811:04:17 Right-SulteO Lhiversai 2019 19.0.08 RS1108101 Page 2 ...Mightsoli H✓AC\DINOLA REVISIONS 6 18 20.n p Cale =MJ8 Front Door laces: W wrightsoft, Right-J® Worksheet Job: AHU 1 Date: JUNE 18, 2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE,FL34946 Phone: 77246E799 Fez 772466-6796 Email: OUICKCALCSOAOL.COM 1 2 3 4 5 Raan name Exposed wall Room height Roan dimensions Roarn area AHU 1 1620 ft 14.3 1t 2344.0 ft' M SAFE SO 1t 9.3 ft heat/cool 4.0 x 6.0 1t 24.0 its Ty Construction number U-value (Btuh/fF-°F) Or HTM (Btu"2) Area Oil a perimeter (ft) Load (Btah) Area (W) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P13 Heat Cod Oros N/P/S Heat Cad 6 11 WJ__13172) Vy VJ� .i Yy l--G T--G W.�- W -G_ W _- _ C _ C F:» 8. 9 8.� 0.00 0.00 ._ 0.99 2.19 23.72 19.26 =0.99 2.19 0,00 =0,99 483 3 0 0 . )- 30 723 72 96 i tr260 93 0 i. (_130 465 16 72 16 48 .=1962 392 _ _=2344 t._. 2&0:`�"-19241252 480 0 0 0 .. '130 555 0 0 _ ;260 93 0 7 -130 313 0 0 0 0 ? 1952 392 _ ... 162 r � ^. _ !_ L.a_ 223 223 0 0 0 0 '�-._ 22 120 0 0 0 =- d 0 0 0 =_a0 0 0 --0 0 0 0 0 0 asp 0 --=0 A4cc 13A-0acs 2gazing, dr bw-e 2 gazing, air low-e 2 gazing, air low-e �0.143CSS 0.300 0.300' 0.300 0.300 =0.065 >_n n n n n ...�4D),_,..Z19:_=484 4.00 640 0.00 0.00 7925 u 0 0 7026 26 0 0 5650,=.._. 56 0 0 0 56 0 0 0 12F w - =a- =182 �'�; 2V =12) ==0 .�0-- 13A-Aaos 2 glazing, air low -a 2 dgzinq cIr la -e .12E"" -0s - 13A-4acs 2 dazing, air Iowa JSFzGdw== 1SA4cca 2 gazing air Il '2 gazing air Il 2 glazing clr laves 2 gb filming clr w-e j6Y '9H ': 16A3Omd �_t�0.- 0.143 0.300 0.300 = 0.065 0.143 0300 ____0,065:w' a a a = a s 4.00 B.dO 840 .F 1.82 4.01) 0,00 _' = 1.82 2224 605 805 =474 1215 1708 1851 0 0 0 0 0 0 0 _ �0 =269 ,TO T_0 :�.�_0 372 0 203 0 0 0 0 0 0 ,T _- 0 q._ _0 0 0 0 0 0 __22 d_ 0 :_. __228 ,f';237 1253 134 605 134 403 -'_J749 351 =6160:, _729 685 379 1703 379 1138 =4372 878 ` 0 0 0 0 0 0 =0 0 0 0 0 0 -4 0 - .. 0 0.143 0.300 0.300 0.300 0300 =0.032 0,032 �y1.358 w w w w w - r_ 4.00 SAO 8.40 8.40 840 � 6-90 090 =:§W 2.19 23.72 23.72 23.72 2172 =2.29 2.24 =0'00 =24 0 O =?A ( i _ -...._v �'-----'r.'- -ram. �. -•^n •--^...� �_ -. �- ^ -�• �T_ �P+�� . �T_ Fes:. �. __- _ -- - 6 c)AED excursion 0 -16 Envelope koelg+in 18169 16372 473 1E0 12 a) srtiftratim b) Rarn veraffatical 4589 0 1317 0 101 0 29 0 13 Informal gains: Occupants W 230 A{yliaroer/aher 0 0 12100 0 0 0 Subtotal (lines 6 to 13) 22757 29789 574 189 14 15 Less eMemal Intl Less tronsfer Redstro-tim Subtotal Duct leads 46% 50% 0 0 0 22757 10364 0 0 0 29789 14781 46% 50% 0 0 574 0 0 0 0 -109 0 0 Total roan load Air regired(ctm) 33122 19B3 44571 1983 0 0 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. �rJlgpft so - 2020.A1n-1811:04:17 . A RlghtSuileOUnhersa1201919.0.08 RSL08101 PageI ...tWnghtsott HVACIDINOLA REVISIONS 6 18 20.rup Cola =MJS Front Door faces: W wrightsoft° Right-J® Worksheet Jab' A yu r Date: JUNE 18, 2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-068-6799 Fax 7724iai S796 Email: OUICKCALCSQAOL.COM 1 2 3 4 5 Room name Emessed wall Room height Roan cimensicns Room area M W IC - 0 It 9.3 It heaV000l 1.0 x 102.5 It 102.5 Its M TOILET 0 it 9.3 It heat/ood 1.0 x 18.5 it 18.5 Its Ty Cautruaion number U-value (BtUVfli°F) Or HTM (Btuwftl) Am (ftq or perimeter (ft) Load (Btuh) Area (Its) or perimeter (ft) Load (Btuh) Heat Cool Grew N/P/S Heat Cool Gross N/P13 Heat Cool 6 11 W.0 lly---G I--(3 L--0 .W =O.W . i'�. 0 0 0 0 0 _ :._0 0 0 0 0 ..._ �0 0 0 0 �_ „'_0 0 0 __0 0 0 0 0 0 - W703 0 _ [._ L=0 r �_ --0 0 0 0 0 - 0 0 0 0 0 ]2as'u-`*_0.065 13A-4 2 gaziroes g, or Is" 2 gazing or ob lr v,s 2 gazing dr bv,s .72EL>svi Ifl.,. -,i`7.62 =°0 0 0 .=0 0.143 0.300 0.300 0.300 n n n n 4.00 840 0.00 0.00 219 8.69 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 = 0.065 ...e_1.82 .` 0.99 [ W�.0 0 0 {`., 0 ! 4._J 0- 0 _ 0 L" �..0 0 0 0 0 0 (.=103 _ 0 i =W i0 0 0 �^ 0 .[0 0 0 ;�._._0 ,____a_0 -_______0��.0 0 0 L.._=0 0 0 13A4oc*, 2 gazing dr lower 2gaz�, air low- 12F_-0sw ' '. _ 1t-'s3A-4oss 2 gq azin_clr bx ^ „1 -0rsy 134-4ocs 2 gazing, air lava '2 gazing, clr low-e 2 gazing olr low -a 2 gazing dr ow-s 16MFD rd._ . - 16A-Omd 0.143. 0.300 0300 -�0.085 0.143 0.300 -0.065 a a Te �.a„ s s ',,,-w_ w w w w w e 4,00 SAO 'm 840 .82 400 000 � n 4.00 840 8,40 SAO 8.40 Q300 090 2.19 23.72 19.28 ,�0.99 219 0.00 =0,9g 2.19 23.72 23.72 23.72 23.72 =224 224 --0.00 0 0 0 0 0 0 0 0 .-=, Ws_!_. W _ W . G.�.i C Fi.=_•. „"_0 �0 w0 =0 --_.,a _.____0 _0. =0 0 0 0 0 0 0 0 _ _0 , _ _ -0 0 _ D _,y 0 _-- a 0 0 0 0 0 = 92 =0 0 0 0 0 0 = MO ,0 0 0 0 0 0 0 0.143 0.300 0.3m 0.3m 0.300 0.032 0.032 1 3W 0 0 0 0 0 =9 0 0 0 0 0 ,-(�-.17 0 0 0 0 0 =- 4J 9 0 -"_:..[0 0 0 0 =19 0 =0 0 „`�_0 0 � 0. 22Af'ph#'„ i' 7t`- - `Ko r r•r_+ T -S 1 a .�._..--.-.� wee_ ...`- ems. 6 c)AED excursion A5 -19 Envelope loss/grin 92 145 17 22 12 a) Infiltration b) Room ventilation 0 0 0 0 0 0 0 0 13 Internal pins: Occupants a 230 Appliances(other 0 0 850 0 0 200 Subtotal (lines 6 to 13) 92 995 17 222 14 15 Less a#emN lead Less transfer Redstnhulim Subtotal Duct leads 46% 50% 0 0 0 92 42 0 0 0 995 494 46% 50% 0 0 0 17 8 0 0 0 222 110 Total roan lead Ar reQdred(ofm) 134 8 1488 66 24 1 333 15 Calculations approved bVACCA to meet all requirements of Manual J 8th Ed. yrr19F�16so 2 ,k n-18 11:04:17 AOGM Right-Suile(3 Universal 2D19 19.0.08 RS1108101 Page 2 ...(Wrightsoft HVACWINOLA REVISIONS 6 18 M.rup Cale =MJS Front Door laces: W wrightsofV Right-J® Worksheet Job: AHU y Date: JUNE 18, 2020 QUICK CALCS, INC. By, 317 ST LUCIE LANE, FORT PIERCE. FL 34946 Phone: 772466 M Fax 772466-67M Enail: OUICKCALCSCAOL.COM 1 2 3 4 5 Room name Exposed wall Room height Room cl'mensions Room area M RATH 13.0 It 9.3 It heatfocol 1.0 x 1%o It 156.0 Ir BEDROOM 3 28.01t 9.3 ft hast/ccd LID x 198.0 it 198.0 IV Ty Conslrudion number U-value (BtuNfii°F) Or HTM (6tuh/ftz) Area (W) ot perimeter (ft) Lmd (Btuh) Area (It) or perimeter (ft) Load IBM) Heat Cod Gross WPlS Heat Cod Gross WP/S Heat Cad 6 11 ,a,�0,99 i _ 0 121 3 0 0 ' = 0 0 0 _ _ 0 '-.0 0 0 � .=,0 0 0 0 0 0 T.=56 0 .. 56 ._i3O 118 0 0 0 .., ;Z0 0 0 - 0 1_ r�0 0 _ 0 _ :. '.10 0 0 0 0 0 '-15 . ,_6 0 __�7:J3 _0 447 0 0 0 =-0 244 0 0 0 �., JZF-gW - _-._u0,065 '� -�.,.1,82 0 472 25 0 0 p �O 1�11'----(�3 I--G W_E, Vy 1�----(G3 ,_ 2 W..-4a W W:r C__.,_ C 13A-400s 2 gazing, clr low-e 2 glazing, clr lore 2 gazir I dr low -a j2E-Osw _ _ 13A-4ocs 2 glazing dr lover 2 dazing, dr lower J2f-6sw.• 1aA400s 2 dazing, clr love_ _72E-0sw 13A-400s 2 glazing clr km-e 2 glazing, clr kw-e 2 glazing dr lore 2 glazirly, dr lore .16A- A71d .... , 16A-3Jmd 0.143 0.300 0.300 0.3W ,4 0.065 0.143 0.300 _�0.300 =Ob657e- 0.143 0,300 _�0,065 0.143 0.300 0.300 0.300 0.300 " ,MA2 0.032 4 1:358 in n in in ..e_ a a - a a s -w_ w w w w w 7- - .- : 400 840 O00 0.00 =1.82 4.00 840 640 _- 1.82 4.00 „�0,00 182 400 BA0 8.40 8.40 8,40 =- 00 0.90 ,�.36.02 2.19 8.69 0.00 0.00 =0.99 2-19 23.72 19.28 =099, 2-19 goo �-_0,g9 2.19 23.72 23.72 23.72 23.72 ..�2.?4 2.24 „_--,0.00 258 26 0 0 112 0 0 0 112 0 0 0 „ =�.LO 0 0 0 _= c.0 0 _0 =6 ,_„_ ----0 .� �0 0 0 0 0 0 0 0 0 0 0 0 _ 0 -0 0 _ 0 _ __0 452 0 302 0 0 ,, _i77 0 „_„1085 0 0 ^,-,0 �_0 0 _0 ,+0 247 0 854 0 0 ,„,__ 444 0 ,-„�0 :,�_0 �-.�._0 �_-O.:r-_ 0 0 = �L __p 0 0 0 0 0 �...t 0 0 _ 0 0 _0 �_0 113 0 0 0 0 =� )S _0 ��0 0 0 0 0 0 =349 0 _�0 149 0 36 0 0 -"198 0 494 0 =98 0 28 =0 - . �._..w_.� 6 c)AED excursicn -1531 189 Envelope loss/gain 1131 481 2443 1977 12 a) Wittration b) Roomvermlation 218 0 63 0 469 0 135 0 13 htemal gains: Occupvnts 0 230 Appliances/other 0 0 1250 0 0 600 Subtotal (lines 6 to 13) 1349 1793 2912 2712 14 15 Less odemal Imtl Less transfer RedstriGGion Subtotal Duct bads 46% 50% 0 a 410 1759 801 0 0 135 1928 957 46% 50% 0 0 0 2912 13M 0 0 0 2712 1346 Tot! roam load Air reguired(dm) 2560 153 ZB84 1Z8 1 1 4239 254 4058 181 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -e}t 20M lun-1811:04:17 h RightSuifeO UnwemaI2019 19.0.08 RSW8101 - Page 3 ..AWrightsolt HVAC101NOLA REVISIONS 61820.mp Cale =MJ8 Front Dog faces: W Na m N m +' m NAmN+ Ps OVA F N V� O Is 11-11-1 -f i DDDTD �e tt QQm rt D� Q o m ii k� fl l'�l f"I (3 1 Id tllsillIlpm �0'm m� "ryNNN+�+'N+WNN 'NN N+V mV?"o 0 io ® II �1 Il € Ii II I� �1 FI I' II fr1 IFFFFF{j1mm 1lmmmypyj»-41 �SLI8mm �I�,gggg8gg8�gg8�!8gg8� NMI ao 1r�'i1 yjjj ' 1{j��1 f I l l ' I 1. r i (II'jjt m m N.000 ov 111.2 f ooo oo0 N 3— 'No u i'i u�m�� o', ��� v mO ul'000 omJ 000 ob oolo. 05 If 'r1(' jf j[ sf x JffJ irq� I�+f1 � Pj{ {[ I loovl[oo N mr0 IF trS000 OAa L7"1 H 1 n f1 r� i:i I� I tl t� `I 11 C� CKON OOOOrO bOrob'.000b1 00001110. � EA I H000I so lop bmmbmf bm mbb �}I I1 f fl E!i El f fl fbbbb�EobblOOb�lbmbbl o0 {n � m i i 1 l, i it ! � ii (I �[i � a (I l 1 1 �' m iI `6'ffi I s m +omo o> I (r l i f i r i] 1 i mo���6'0 00000000.00000 ]jj`ff` [j!{!{ ..a ^ IIII C`C` IjJ 11 II �oo E[E[tt 4 $ 9� 5n 11 II II O000li u000 Ica wrightsofir Right-J® Worksheet Jab: AHU Date: JUNE 18, 2020 QUICK CALCS, INC. By: 317 ST LUCIE IAINE, FORT PIERCE, FL 34946 Phone: 772,16"799 Fez P246"796 Email: CUICKCALCS®AOLCOM 1 2 3 4 5 Room name Enqaosed wall Roam height Rosen dimensions Roan area WIC 2 &0 It 9.3 It heatl000l 1.0 x 52.0 It 52.0 W BEDROOM 2 21.0 It 9.3 It heat/000l 1.0 x 187.5 It 187.5 Its Ty Construction number U-value (Btuh/fti°F) Or HTM (BtutyR2) Aran (Ilq a Perimeter (ft) Load (Btuh) Area (ftq or perimeter (ft) Lead (Btuh) Heal Cool Gross N/P/S Heat Cod Gross N/P/8 Heat Cad 6 11 37 0 0 0 _ -0 0 0 0 . 1: �.:0 0 .. _ _0 37 0 0 0 0 _._�:52`�T 0 _ L �u v8 0 0 0 0 0 0 0 0 W „ � W I---G IL- W :'.__ .7PF�Osw. _ _ 13A4acs 2 gazing, ctr low 2 glazing. dr bv-e 2 gazirxy o1r lay-s TaWw 7 ^"0.065 = 1.82 �0,99 t =-O 149 0 0 0 81 0 0 0 0 0 0 0 0 0 0 0 0.143 0.300 0.300 0,300 MJ65 a n n n _a.. 4.00 8,40 0.00 0.00 =2 2.19 8.69 0.00 0.00 =88 37 0 0 0 : c 0 0 0 t = 0 0 0 �_, 0 37 0 0 0 0 52 0 ,.. =52 0 �0 0 0 0 _' '._ `0 0 0 _ 0 �_v 0 13A-4ocs 2 gazing ctr kw-e 2-gazirlyclr to -a laA-flocs 20azlnq clri w-e 12F-0sw 2 glazing ctr Ivx� 2 glazing, 2 glazing, ctr low-e 2 gazing olr low-s 2 gazing clr lore 1 d':- :` 0.143 0.300 0300 ��0,065 a a �e 4.00 8.40 _840 ,_,.eL82 2.19 23.72 19.28 =0.99 0 0 0 ..e0 0 0 _0 ,,„®,)_0 140 0 0 0 0 �a0 0 yJ3Q4 0 0 0 0 0 0 0 0 0 W �--G_ W%' Yy IIIL-----GGGG C a F7,�� -0 _._=v_0 �0 0.143 _0,300 �,0.065 0,300 0.143 0,300 0.300 0300 .'0.=>.---40i�2.24; L358 �L358 s s ,..w_ w w w w w � 4.00 000 �7 82 4.00 4.00 8.40 8.40 840 Sagoc2 '`38.42 219 _0,00 ^0,99 2.72 23,72 23.72 23.72 23.72 224 =0.00 0 0 56 56 � _ 0 �___ 0 122 _0 ___ -0 ,^.-o _0 �0 _0 0 81 0 0 0 0 11a,�:y188 0 140 0 36 0 0 0 .�1$8 10a 0 0 0 0 i>�.: 760 0 =1 414 0 302 0 0 i60 0 '`,...��I09 2 0 0 854 0 0 �_40 0 =0 164SWntl 22A_-tFi1" m� =0 -77 6 a)AED a=ursion -29 189 Ernebpe losslgsln 649 250 1907 1811 12 a) Infiltration b) Roan %entilation 134 0 38 0 352 0 101 0 13 Internal gains: Occupants ao 230 ApFlionces)olher 0 0 50 0 0 S00 Subtotal (linx 6 to 13) 783 339 2259 2712 14 15 Less internal load Less transfer Redistribution Subtotal Dud Imd; 46% 50% a 0 0 783 356 0 0 0 339 168 46% 59% 0 0 0 2259 10-19 0 0 0 2712 1346 Total roan load Air respired(cfrn) 1139 681 507 231 3287 197 4056 181 Calculations approved bV ACCA to meet all requirements of Manual J 8th Ed. 2020.Wn-18 11:04:17 RightSuile0 Unn2rsai 2019 19.0.OS RSU08f 01 Page 5 ...\Wrighlsoft HJAC1DINOLA REVISIONS 61820.rup Colo =MJ8 Front Door faces: W wrightsofe Right-J® Worksheet Job: AHU 1 Date: JUNE 18, 2020 QUICK CALCS, INC. By- 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 7724666799 Fes 772.466-67% Email: OUICKCALCS090L.COM 1 2 3 4 5 Room name Et7iosedwall Room height Rcom dmensims Room area PANTRY 0 it 9.3 it heat/oocl 6.0 x 6.0 it 36.0 IF KITCHEN 0 it 9.3 it heat/cool 1.0 x 174.0 it 174.0 fl= Ty Construction number U-value (BtufVfRfl Or HTM (Btuh/ftz) Area 09 or perimeter (it) Load (Bich) Area (ft� or perimeter (it) Load (Btuh) Hart Cod Gross N/P/S Heat Cad Gross N/P/S Heat Cod 6 11 .W 4y Its--OGG -72F_ibW lak loos 2 glazing, ok loves 2 glazing, dr kw,a 2 glazing, dr 1cw,a 1344ecs 2 goring dr Ivxe 2.dpzina`clr luwe Al FEW 13A-400s 2 Owns, air lowe lak,laos 2 glazing, dr lowe 2 glazing, dr Iowe 2 glazing clr kwa 2 glazing, air lowe 167t3pnd- -' 16A30md 22A-td1; r a"0,065 0.143 Q300 0.300 e300 .�t0,065 0.143 0.300 0,300 = 0.065 0.143 0 300 ;7t_ n n n n "e_ a a a _o_ 5 s =, 82 4,00 8.40 000 000 =Vkz 4.00 840 840 _ .iff 4011 a- ._-0.69 2.19 8.69 0.00 0.00 =0.99 219 23.72 19.28 =0.99 2.19 0.00 =0,93 2.19 23.72 23.72 23.72 23.72 �'�2.24 _2.24 _,.0.00 I = 0 0 0 0 0 I =-'o 0 0 0 1 =0 a 0 I __0 0 0 0 0 0 = 36 r 0 ...ram_ 36 . ,_ �0 0 0 0 0 _ i_:_0 0 0 0 . '�0 0 0 _ :' - 0 0 0 0 _ 0 _ .�. _:3() 0 _.�0 --r ?d0 0 0 0 0 =�,.._...w0 0 0 0 0 ,� '0 0 0 0 0 -�_0 0 0 0 0 �0 0 0 0 0 ,� 0 0 0 0 0 ly `BOG W a C -C F-"_ --_I T-0 , 0 �b �0 �: _ 0 0 0 0 =,._ 0 : 0 0 0 0 __-_0 0 0 0 a 0 0 =0 0 0 0 0 0 .132 0 0 0 0 0 0 0 0 0 =0 . :o =0 0 0 0 0 =0 0 0 0 0 0 =t4 0 0 0 0 --0 0 0 0 0 0 156 0 0 „"-"___,"-0 0 0 0 0 0 39J 0 0.143 0.300 0.300 0.300 0.300 trbW w w w w w y_. =18p 4,00 840 8A0 840 840 _-0 .90 =0 0 0 0 0 0 =Q �0 0 0 0 0 0 --1Z4 0,032 1 358 - = 090 =38.02 0 , _�Q 0 0-.,�_. 0 173 0 =0:�._00 �0 - 6 c)AED ercursim 30 _266 Envelope loss/{pin 32 51 156 123 12 a) Infiltration b) Room ventilation 0 0 0 0 0 0 0 0 13 Intend gains: Comports ® 237 Ap fiances/other 0 0 300 0 0 30o0 Suttdd (lines 6 to 13) 32 351 1561 3123 14 151 Lass wdenval land Leas transfer Redsoibutim Subldd Duct Was 46% 50%1 0 0 0 32 15 0 0 0 351 174 46% 50% 0 0 0 156 71 0 0 0 3123 1550 Total roan Intl Air rogArod(cfn) 47 3 525 23 227 14 4673 208 Calculations aDDroved by ACCA to meet al I reauirements of Manual J 8th Ed c � `^"-t9ti�vT- 202DJun-1611:04:17 �A RightSuiteO LIniversal M19 19.008 RSUD6101 Page 6 ... \W rightsoft HJAC{01NOLA REVISIONS 6 18 20.mp Cats =We Front Door faces: W +j+wrightscitV Right-JO Worksheet Jab: AHU 1 Date: JUNE 18, zozo By: QUICK CALCS, INC. 317 ST L11CIE LANE, FORT PIERCE, FL 34946 Phone: 772-0666799 Fax 772466-6796 Email: OUICKCALCSCAOL.COM 1 2 3 4 5 Room name Eposed wall Room heigrt Rcom dimensions Roomarea BATH 0 /t 9.3 It heal/ood 1.0 x 103.5 It 103.5 ft-' DINWG 16.0 In 9.3 It heal/cod 16.0 x 15.0 ft 240.0 Its Ty Construction number U-value (Btuh/ftMF) Or HTM (Btutvh9 Area (fts) a perimeter (ft) Load (Btuh) Area (fij a perimeter (ft) two (Btuh) Had Cool Gross NIP/S Heat Cod Gross N/PIS Heat Cod 6 1 t 0 0 0 0 0 , i � 0 0 0 0_ I...= 0 0 0 ., j= _0 0 0 0 0 0 a_=107 0 - _=04 _. 1,;=0 0 0 0 0 ._ _' t;_0 0 0 0 =0 0 0 _ : v0 0 0 0 0 0 . _ 1"ZfOul 0 _ . _.i.0 ..`i -70 7_ __0 0 0 0 0 r _0 452 30-1 0 . ._.0 =0 0 0 0 0 W;.,�. J2F�w �. ' ;:._0,065 � =82 ,,,„_0.Q9 =i:l �0 lV (--G ll----.GG W� Vy Ih-.--CGi W �G .W � 0 F= 13A-4ors 2 glazing db r v-s 2 glazing or low-e 2 gazing or Icv-e .12F-405' 13A-4ace 2 grazing dr lcw a b 2�ing, clr we 13AAcce 2 plazin9, dr lova 12F�w. -1 134-4o s 2 gazing, dr lava 2 gazing, ctr lava 2 g1azmg dr kw s 2 glazing, clr bxa 16Aa0nd 22Q-017 0.143 0.3W 0.300 0.300 n n n n 4,00 1140 0.00 0.00 219 8.69 0.00 0.00 =0.99 2.19 23.72 1928 ..=99 279 O.W _0,99 2.19 23.72 23.72 23.72 23.72 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 '6065 0,143 0.300 0300 =ab65 0.143 0.30D =0,065 Q 143 0.300 0.300 0.300 0.300 =7�0,032 _e- a a a Z:Z s �s = w w w w w = 82 4.00 8.40 8.40 =.S2 4.00 0.00 =L62 4.00 8.40 8.40 8.40 840 ^ i_0 0 0 0 =70 ==0 -7--:70 0 _- � 0 247 854 0 ryZ=0 0 0 =0 0 0 0 0 0 '538 0 =0 0 0 0 149 36 0 113 0 0 ::--0 � 0 __ 0 0 0 -=0 0 0 0 0 0 =93 0 =;0 0 0 0 0 0 0 0 0 . _ _0 0 0 0 0 0 =2iS 0 =603 '0 0 0 0 0 0 =232 0 ..0 0 0 0 0 0 = 240 0 r„®,-_240 =0 0 0 0 0 0 0 -'�.-�6 a =105 „=274 2,24 : 0.00 0,032 =' K358 - 090 ;=36.02 =0 1 _si S 7-7-G 6 c)AED excursim -73 -171 EmMope loss/gain 93 159 1577 1463 12 a) Infiltration b) Roornlentilation 0 0 0 0 268 0 77 0 13 blame] gains: Occupants a 230 App]ianceo/other 0 0 700 0 0 1600 Subtotal (linot 6 to 13) 93 859 1846 3145 14 15 Leis eltemd laid Less trmsfer Redstritxtlm Subtotal Duct foods 46% 50% 0 0 0 93 42 0 0 0 859 426 46% 50% 0 0 0 1846 84111 0 0 0 3145 1560 Total roam Iaid Air restored(cfm) 135 8 1285 57 1 2686 161 4705 2W Calculations approved byACCA to meet all requirements of Manual J Sth Ed. -1*- wr19h1GsoR' 202DJun-18 11:04:17 A- & RightSuile® universal 2019 19.0.08 RSU08101 Page 7 ._1Wnghtsoa HJAC(DINOLA REVISIONS 6 18 20.rup Cola = MJ8 Front Door faces: W �{+ wrightsofr Right-J® Worksheet Job: AHU 1 Date: JUNE 18, 2020 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-laa-a 9 Fax 772A666796 Email: GUICKCALCS@AOL.COM 1 2 3 4 5 Room name E)pmed well Roan height Roan dimensions Raxn area MASTER BEDROOM 34.0 fit 9.3 It neaVo:lal 1.0 x 257.0 it 257.0 IN GREAT ROOM 17.0 It 31.5 It heat/ood 1.0 x 624.4 ft 524.4 W Ty Construction number U-value (BbuVwF) Or HTM (etuhiltz) Area (ftj a perimeter (ft) Load (Btuh) Area (tts) or perineter (It) Load (Btuh) Heat I Cod Gross N/P/S Hoot Cod Gross NUP/S Heat Cool 6 71 Wl= W �_G W,..= 12F�Gw. 13A-0as 2 gazing, clr bxa 2 gazing, dr Ivva 2 gazing, dr Iowa .12F-Ww_ 2 gazing, dr bva 2 gazing. 1217-0na dr bv� ,12F_-0a`w: P905 .�R.. �].82 . �0 9 = 0 158 0 0 0 I._`i8._..14.__2 136 36 .....__�.0 _ lu 0 158 0 0 0 120 0 0 _ :-. T.- 0 0 0 l rr `0 0 0 0 0 0 . __;267 0 _ ;_-.34 _R__474 0 0 0 0 �237. 1280 0 806 T-_474 0 0 = 237. 0 0 0 0 0 ` - 118 351 _646 "' � ' 0 0 0 0 ��01 701 0 1251- �. r�25g 0 0 .7--D 633 0 0 0 �O 346 0 0 0 =260 0 0 0 0 =417 =260 0 0 0 0 =321 0.143 0.300 0.300 0.300 n n n n .a_ a 6 a 4.00 8,40 0.00 0.00 =4,00 8.40 8.40 840 219 8.69 0.00 0.00 _2.19 2.19 19.28 19.281-r�0. =0.99 =0,143 0.300 0.300 0.300 .�J:.0.065 �1. 89 302 300 0 = �0 0 0 �0 267 854 0 b10 96 6 320 0 0 =260 0 0 _s_ `i 82 _._0 0 0 _260 0 0 W 13A-4ocs 2 {lazing, clr Iowa 134-40s 2 gazing, clr Iowa 2 gazing dr Iowa 2 gazing dr bwa 2 g mirrg, cIr Io -e .18A3*d -. .. 16A-30md -"2-A'.-fpb 0.143 0.3W =.0.085 0.143 0.300 0.300 0.300 0.300 _..9,032 a a .ill_ 4.00 000 =182 219 e00 _ 0.99 0 7,^ 0 __._.� : o ___-_r ._>_o 0 0 0 0 0 =239 0 ,._'1293 JD 0 0 0 0 0 ` 598 0 160 0 0 0 0 0 =-32 30 0 0 0 0 0 32 - ;,.1p9 0 0 0 0 0 = 29"y 873 =0 w w w w w ,_=, 4.00 8.40 8.40 8.40 8,40 .,� 0,90 2.19 23.72 23.72 2a72 23.72 =2.24 0 0 0 0 0 -=267 0 = 207 _ Tr C:.y..•_ O 0.032 - rt- 0.90 =38,02 2.24 �OAA 392 ` 524 392 -=17 =358 0 6 a)AED exursim -140 S6 Erne" lma/gilt 2956 1925 4628 4467 12 a) infiltration b) Roan ventilation Sm 0 164 0 2158 0 619 0 13 Internal gains: Occupants ® 230 AH.aiances/other 0 0 700 0 0 2000 Subtotal (Gres 6 to 13) 3526 2788 6786 7087 14 1151 Lass eternal load Less transfer RedsMbutim Subtotal Dud load; 46 % 50%1 0 0 161 3690 1681 0 0 54 2842 1410 46% 50% 0 0 0 6786 W91 0 0 0 7087 3517 Total roan load Alr respired (cim) 1 5371 1 322 4252 189 9877 591 10603 472 Calculations approved bV ACCA to meet all requirements of Manual J 8th Ed. 2020Jun-16 11:04:17 �^ZcA RightSuiteO Lrwsal 201919.0.08 RSUJ8101 Page 8 -AWnghtsoh HVACIDINOLA REVISIONS 6 18 20.rup Cato =M,18 Front Door faces: W wrightsoft, Right-J® Worksheet Job: AHU 2 Date: JUNE 18, 2020 QUICK CALCS, INC. By: 317 ST LUCIE TAPE, FORT PIERCE, FL 34946 Phone: 7724666799 Fax 77246 6796 Email: OUICKCALCSCAOL.COM 1 2 3 4 5 Roam nanre Exposed wall Roan 1,01g1t Room dmensions Rcorn area AHU 2 _ 95.0 It 9.3 It 1035.0 R° KITCHEN 2 15.0 ft 9.3 It hmtl=l 13.0 x 15.0 1t 195.0 IV Ty Cwwtruction number U-value (BtuhNt-F) Or H]M (Btutvtt9 Area (W) or perimeter (ft) Load (Btuh) Area (ttj or perimeter (ft) Load (Btuh) Heat Cod Gross WP/S Heat Cod Gross N/P/S Heat Cool 8 11 Yv_, ly I --G II--1Gj VI/ _ `BOG W ]'..E.{isw - _a;�0.065 _n,.000 =0.00 2.19 0.000 8.69 8.69 .=0 251 24 40 I.= 214 18 0 = o 419 6 -0 0 0 0 0 0 r. 2=7035 _ 0 _`1035 ._ �=0 187 0 0 0 _ .1.:_%_0 196 0 _ 0 ._ _ ...A 413 6 .__'�0.r0.- 0 0 0 0 0 = ,._a035 s 0 _.t_ :..95 `___ 0®0 _:,u0 ___0�0 �0 13A4ocs 2 gazing, air low-s r le 2 glazing. air 2 glazing, cur low 'U�F{ow - 13A41ocs 2 glazing cur low 2.dazinp, dr low-e w J2E = - 13A4ces 2 pazirp, Or low -a 12F_-0,w0,065 0143 0.300 0.300 0.300 n n n n 400 0.00 840 840 749 0 � 336 =E0 409 a 200 348 0 o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 =10 (w 0.143 a300 0.300 _0.065 .�. 0.143 0.300 7Z a 8 a ms._ s s w =0,00 4.00 8.40 _000 = 000 4.00 8AD _6000.00. R00 0.00 0.00 0.00 000 (90 =000 2.19 23.72 0.00 -0.00 2.19 8,69 0.00 0.00 0,00 0.00 0.00 =V 4 0.00 ,_„__000 TO =0 __a0 _ _..0 0 0 _ 0 ,..;. ,`0 535 50 00 �6 0 0 0 = 0 292 52 784 151 0 =1^0 429 427 0 0 0 0 0 _0 =0 ____;,_�0 _0 _�,�0 1652 50 903 52 140 6 134 6 t700. C F7,� ,. 13A400s 2 glazing our low-e 2 glazing our low-o 2 glazing dr lower 2gazing,drlow-e J6A30ind 16A;Akno 2niE`tpti_-� v 0.143 0.30) 0.300 0.300 0300 ;�i 6032 w w w w w ,. 0 0 0 0 0 .927 _0 "-3612=0 0 0 0 0 0 =18 0 0 0 0 0 0 =95 0 w ?95 0 0 0 0 0 � 795 0 _... 16 0 0 0 0 0 ,,E_775 0 ..� 670 0 0 0 0 0 .� `43Z 0 0.032 �J 358 - ^'.. 000 =. _ _..�.� ,�38,02 =0 17 - - .-Lot ...�.. -=.,_. - 6 c)AED excursion 0 -10 Ernelops loos/gain 8464 5094 1330 772 12 a) 6viltraticn b) Room ventilsticri 1592 0 457 0 251 0 72 0 13 htemal gains: Occupants 49 230 Applimises/other 0 0 8000 0 0 1800 Subtotal (lines 6 to 13) 10056 13551 1581 2644 14 75 Less external Imtl Less tramier RedstnlbAim Subtotal Dud loads 28% 30%1 0 0 0 10056 2776 0 0 0 13551 4045 28% 30% 0 0 0 1581 437 0 0 0 2844 789 Total roan load Air regrired(dm) 12833 80] 17598 800 2018 1-1 34M 156 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. -!}/- Vr19�+1taoR- pp.Wrf1811:114:1] RiISIO l 6 18 20. u pC 19.0.08 RS or ID Page 9 _.1Wdghtsott HVAC1DINOLA REVISIONS6 18 p.rup Celc=MJB Frw[Door tacos: W wrightsoft Right-J® Worksheet Job: AHU 2 Date: JUNE 18, 2020 QUICK CALCS, INC. By. 317 ST LUCiE LANE. FORT PIERCE, FL 34946 Plone: 7724666799 Fax 772466-6796 Emil: GUICKCALCSOAOL.COM 1 2 3 4 5 Room name Exposed all Room height Roorn dmensions Room area WING 13.0 it 9.3 It heaVcod 1.0 x 242.0 it 242.0 IF WIC 5 8.0 it 9.3 1t heabood 6.0 x 8.0 It 4&0 It' Ty Construction number U-value (etuh/ItLoF) Or HTM (f3 UMV) Arm (fl) or perimeter (ft) Lodd (Ruh) Area (ft� or perimeter (ft) Load (stun) Hest Cod Gross N/P/S Heat Cod Gross WP/S Heat Cool 6 71 .Nr Vy tL�-.GGa W= W _ 4yla= �2F_-( w '' ":�''-0.065 13A-,leas 2 gazing, d� r lv 2 glazing, dr b" 2 glazing, dr la - 12E--b _ 1aA-4ms 2 glazing dr low-e 2 Ominq_gr to - '.I - - 1a4-0am 2 gazing, clr fow� JZGC W 2 glazing, clr lava 2 giazi g, 2 glazing clr low-o 2 glazing dr law-e 2 glazing, dr low-e 16QQio0= .JL =0 400 0,00 840 640 =000 4.00 8.40 0,00 =0.00 4.00 8_40 0,00 219 0.00 8.69 8.69 =0,00 2.19 23.72 0.00 =0.00 2.19 &69 ,_�0.00 000 0,00 0,00 0.00 0.00 `.� f,14 : 0 121 0 0 40 -.=.0 0 0 0 - +.'',- r-0 0 0 : W< 0 0 0 0 0 0 F-'ym.�.242 0 ._L' P42 _ : 7-:0 81 0 0 _ 0 .' I=o 0 0 0 .. i�=0 0 0 -_ �_ a--0 0 0 0 0 0 .._w.mf252 0 �. i. �:13 : 0 .0 =0 �_.. �_0 0 0 0 0 -- o .- �=4 0 0 0 0 :: -d 0143 0.300 0.300 0 300 ____..0665 0.143 0,300 0,300 =161i 65 0.143 0300 n n n n =. a 6 8 - s_ s s 324 0 0 336 _.=40 177 0 0 348 -o 0 0 0 0 =b 0 0 0 0 =Do 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 =<.+n.0 0 _�0 .�.:.,..-0 �_0 0 �,® �.�_,..0 T _,;., 6 0 0 74 74 0 298 0 163 ..,_.: 64S5:7Z =WCO r0 .>ti.,.,� Q 0 0 0 0- 0 21 0 .._........„,0 0 0 0 0 0 """"5'42 0 . .'0 ^��0 ,_a,�_0 0 0 0 0 0 =`'48 0 �..;,.48 0 ,-__ e0 0 0 0 0 0 43 0 = 304 ���0 -0 0 0 0 0 i�_ o =Q8 0 ::=-0 0.143 0.o300 o300 0.300 0.3)) ;0;M w w w w w U00 0.00 OM 0.00 0,00 =90 0 0 0 0 0 �. A6 0 8 O 16Aa0nd 0032 000 0.00 =0,00 224tW.-...- _ _ _ _-"'^ :356 's"3 02 =994 _`. ,-=--s-•-= -�'-- ^.r_^....' _ _. ._.�..;..i n ....emu '----fit--- ----•�-- _- -•--,.�..-.e..,--, --•---r-„ _ ._-�� -�.--.. i..- _.._.,..-.^ 6 c)AED ex .1. -12 -2 Envelope bss/gvn 1371 1055 645 26B 12 a) Infiltration b) Room vatlilation 218 0 63 0 134 0 38 0 13 Intemal gains: Oooupsnts0 230 Applianoes/other 0 1 0 2100 0 0 1 250 Subtotal (lines 6 to 13) 1539 3218 T79 557 14 15 Less ebemai Imd Loss transfer Recistribution Sudaal Dud Baas 2B% 30% 0 0 104 1693 467 0 0 55 3273 977 28% 30% 0 0 0 779 216 0 0 0 557 166 Total room load Air regrirad(ofm) 2161 135 4250 193 994 62 723 33 Calculations approved bVACCA to meet all requirements of Manual J 8th Ed. -rI+ wri9E+lso4 !' 2020.Wn-18 11:04: 17 .9G�A RightSuite@ Universal 2019 19.0.08 RSLIOB101 Page 10 ...\Wrightson HVACkDINOLA REVISIONS 6 18 20.rup Cain =MJ8 Front Door laces: W wrightsofL Right-J® Worksheet Job: AHU 2 Date: JUNE 18, 2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL M946 Phone: 772-4666799 Fex 772-1665 96 Email: DUICKCALCSCADL.COM 1 2 3 4 5 Room name EN=ed wan Roan height Room dmensiaxs Roanarea BATH 3 0 it 9.3 It heat/ood 7.0 x 8.0 It 56,0 it BEDROOM 5 z8.0 It 9.3 It heat/000l 12.0 x 16.0 It 1g20 It- Ty Constriction number U-value (Btuh/Itx°F) Or FIRM (6tuhRt9 Area (ft) or perimeter (ft) Load (Bluh) Aran (ftq a perimeter (ft) Load (Btuh) Heal Cod Gross N/P/S Heat Cool Gross I4)P]5 Heat Cool s 11 ;.-:= 0 0 0 0 0 ..0 0 0 0 I_G=_0 0 0 t �'-'_0 0 0 0 0 0 , r�56 0 ,_ 56 __....._ _ �, ,._,0 0 0 0 - 0 _.'_�0 0 0 _ -0 __ s. i:�0 0 _ 0 _ i_ ^L0 0 0 0 0 _ 0 r._ _.Cn6 0 Vy- ;12E�w ��0.143 0.300 0.300 0.300 0.300 _n., n n n n __ y4.00 0.00 O.W 8.40 6.40 0.00 2.00 0.00 8.69 8.139 �_. .�.�...Z0 0 0 0 0 ...._s...._0 „_0 ____�0 �.,. _ 0 0 0 0 0 .-._�. e...__.._0 0 0 0 0 Yy L��OOG 2 gazing, clr low-e 2glazi13A-4g, 2 gazing clr Iowt 2 o@;ng clr ICw6 - J2E4cw 2glazi g, 2 oozing clr lIaN-oow-a 2,gazirip, clr Iowe '-�- 0 0 0 0 0 0 0 0 0 0 0 0 --- W 4y -- 10,143 0.300 0.300 0.300 0.143 :_.e., a a a _a_ c --' OAD 4.40 6.40 0.00 :_.D.00 8.40 --- _0.00'_" 2.72 23.72 0-00 ,_,_2.19 z.69 e.� =0.00 0.00 0.00 0.00 0.00 0.00 , =2.4 0.00 ^'0,-b0 :%0 `....__0 .,-.h 90 - 70 2_0 =0 0 0 __„ 0 ....�._..�0 0 0 0 0 0 0 0 0 �'50 0 =-0 0 0 0 112 18 94 0 0 375 150 -0 .__8 205 420 427 0 �0 01_0 TO 0 W _�_-,-C W= lVVllyyyyy I--G ItL--�pG C.` C F= 1S44co 2 gazir�p, clr bn� 2omigs j2F4kw 0.143 0.360 0 0 140 0 149 s9fi __ o j_,_,-0 0 0 0 0 0 172 0 =1065 320 � o ,��_0 0 0 0 0 0 „��30 0 0 �.0.143 _w_ w w w w w ,_840 �0.00 0.00 0.00 0.00 0.00 000 -. =0.90 0.00 ;•.�30.02 �0 0 0 0 0 0 0 0 0 0 0 0 �o _0 134-4ax 2 glazing, clr low-e 2 gazing clr law-o 2 gazing, clr low-e 2 glazing, clr low-e ,16AOid•_ - ~<s 16A-Mnd 0143 0.300 0.300 0.300 0300 0 0 0 0 0 , J9z _T0.032- �125 ;,�_192 0.032 0 =0.T192� 0 0 28 22h11'7M'::.. + 1358 - • -.'_-._..0 6 c)AED excursion S 40 E-bpe loss/fin 50 122 2358 1427 12 a) Infiltration b) 0 0 0 0 469 0 135 0 13 Internal gains: Occupants ® 230 Appiances/other 0 0 750 0 0 900 Subtotal (linos 6 to 13) 50 672 z828 2462 14 15 Less external lead Less transfer Recistnbution Subtotal Duct bads 1 29%1 30% 0 0 1 51 141 0 0 3 875 261 28% 30% 0 0 4 2832 782 0 0 11 24M 738 Total room Imd Air required (cfm) I 1 65 4 1136 52 1 3514 1 225 3211 146 Calculations approved bV ACCA to meet al I requirements of Manual J 8th Ed. wr19hlvof[' 2020Jun-18 11:04:17 I&K RigtSuile® Lhiverse12019 19.0.08 RSU08101 Page 11 ... Wrightsoft FMACtDINOLA REVISIONS 61820.rup Cole =MJ8 Front Door faces: W wrightsoft• Right-J® Worksheet Job: AHU 2 Date: JUNE 18, 2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE. FORT PIERCE, FL 34946 Phone: 7724666799 Fax 772-01 6 96 Email: GUICKCALCSCAOL.COM 1 2 3 4 5 Roan runie Expaed wall Room height Rcon1 dmensi ns Roomarea BEDROOM 4 23.0 it 9.3 it heal/cod 11.0 x 12.0 it 132.0 It-, HALL 0 it 9.3 it heat/cool 5.0 x 4.0 it 20.0 iR Ty Constmcticn number U-value (DWIViR°F) Or HTM (Btwftl Area (ft9 a perimeter (it) Load (Btuh) Area (R) a Perimeter (it) Load (Btuh) Heat Cool Gres N/P/S Heat Cod Gress N/P/S Heat Cod 6 11 W"„„; a ; .0 112 0 24 0 ;-= 0 1M_ 0 0 I-L�_0 0 �T.8.69 0 i O 0 0 0 0 0 32 a ,`-L-132 _._ i.i._0 88 0 0 _ 0 _ . ;,-0 r 102 0 _0 ---=0 0 _ 0 _ ._ _0 0 0 0 0 0 _ _ -132 0 .._i 23 =0 =0 0 0 0 0 =0 .12F�yy - 13A4ocs 2 glazing, clr lower 2 glming, cir Iowa 2 glming, clr loin 0.065 0.143 0.300 0.300 0.300 ,_ n_ n n n n .=OAO 4.00 0.00 8,40 8.40 ,=(AO 219 0.00 8.69 8.69 r0.00 = -�G , �,=0 =0 =0 351 0 202 0 192 0 209 0 0 0 0 0 0 0 0 0 0 0 0 0 %W : ` W_ - J2F_Yw - - 13A-40M 2 giming dr lower 2(jmina drbwa ;12E-w ,=0Ab5 _e_ Rico =-o 0 _ b _' � _0 0.143 0.3DO 0.3DO _O.065 a a a ems.. a 0_ z w w w w w 4.00 8.40 R000 =0.66 4.00 _„g,8,440 00 0.00 HO O.OD 0.00 0,00 =1690 000 =38.02 2.19 23.72 0.00 =0.00 2.19 _ =0,00 0.00 0.00 0.00 0.00 0.00 =2.24 0.00 _0:00 410 0 0 224 0 0 0 0 0 0 0 0 0 0 0 _O 0 _ _0 0 0 0 0 0 0 0 0 0 0 G.5 0 _Do -0 �O 77--0 Vy `C W2 WWWWVy F--L9 God C 13A-4ocs 2 gmimq olr Io -o J2F{GW 13A.-4ocs 2 glazing, clr Iowa 2 glazing clr Iowa 2 glazing dr Iona 2 glazing, sit Iowa .189at0'Dd.� - 16ASWnd 22A7t-pF - 0.143 0.300 =_0.085 0.143 0.300 0.300 0.300 0.300 0 0 a a 0 0 0 0 =0 0 0 0 0 0 ,� ' 118 0 875 �___O 0 0 0 0 0 =O 0 0 0 0 0 0 0 0 0 0 0 0 0 0 _ 0 8 0 --, _0 =0,032 0032 -7=1358 `- , - � =20 ==20 0 0 .^= -0 0 -20 ,�a , -0 -•-- .4 ,--ram �_.,w _ __ _ "T""` ___•_� 6 o)AED eoismion 1 -7 0 Envelops loss/gain 1955 913 18 45 12 a) Infiltrctioo b) Room Ventilation 1 385 0 ill 0 0 0 0 0 13 Internal gains: Comports® 230 Applivxeolother 0 0 1000 0 0 0 .Subtotal (lines 6 to 13) 2340 2023 18 45 14 16 Leas e#emal load Less transfer Redstribution Subtotal Dud loacb 28% 30% 0 0 103 2443 676 0 0 52 2076 620 28% 30% 0 0 -18 0 0 0 0 -45 0 0 Taal room load Air respired (dm) 3118 194 2195 123 0 0 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -I- wr19F+�uR- 2020.W 18 11:04:17 RightSuileO Uhivemal M1919.0.08 RSLI08101 Page 12 ...1WrighlsoB WAC1DINOLA REVISIONS 61820.rup Cas=MJ8 Frmt Door laces: W �R a �a N� oti W� m� S.ww E. A[L w eV^V � A b0'J6 11 1 GNNN Ntu N��+:NN NN NuwI 0 �c kp-� k� �:� k19 k� ky� kk k�y ka �k �1 I, 14 cy+±15�5�YlO foa S. Woo�QlSoao �p�o �o2o bi:KSi3R5C2525�Yn'35�Yn�25�YnfC���Y'� QO��a000 S2 T� k� Fi r� � �� �� i� ��� ��� �� �� k� �� �� �� ►•� Ifm f, AffN �18888888858$1�8$SBf]�B$$881 f1 � _ � � fJ lCjf!' (1E�`r]I1I1 1_1 1II { 1 [1 G] [iI[1I!ILf U uN i �lg 3 .I I f I E I I II' III f I I� i_ [i j !i I) OON000OO 00 N0.04 NO HH12'HSHHHHFdmBSNmH:ffiSHmH' Gm O O - O I NONOOOOOOOOOOOOOOOO.DO &�7 O L� 8� 11 I I !� f f 11 I i I I i� f( I� I� I I f 1 I I NI01.1000000100 �f0000.00000 v X Off/ 00 00800 81 ok' O1 11 r C1{{ I i t7 H 1 n (_II��J(.��i H I�I rI 17 {�7��� f l moP'o o o o0001oo `d'i o 00000�1. 000'O 000 .� hoi �i ��� �1.uo M ka !�i F1 f�� 1 I•� 00011110011 ooa N •T O oz �lI E 1oo x 4-8� I f � o 00�O �Oo i 0 00� o 0 o0 o`� -!Oo0 d pq��q. `j 7jC' I `j '+ { �I 1V}{I i I� i r 1.011..01` $ lr5000 X 4� t{i I Ei 1 l� 1� a0aaai IL7 G 1 w 0 N . C m m m 0 0 F} wrightsoft° Duct System Summary AHU 1 QUICK CALCS, INC. 317 ST LLICIE LANE. FORT PIERCE. FL 34946 Phone 772A66-6799 Fes 71246GW96 Email: GUICKCALOS®AOL.COM Project Information For: DiNOLA RESIDENCE 6000 HICKORY DRIVE, FORT PIERCE, FL34982 Job: Date: JUNE 18, 2020 By: Heating Cooling External static pressure 1.00 in H2O 1.00 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 1.00 in H2O 1.00 in H2O Supply/ return available pressure 0.500 / 0.500 in H2O 0.500/ 0.500 in H2O Lowest friction rate 1.000 in/100ft _ 1.000 in/100ft Actual air flow 1983 cfm 1983 cfm Total effective length (TEL) 260 ft Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (it) Trunk BATH 2 c 1285 8 57 1.000 6.0 OxO VIFx 32.3 135.0 st3 BEDROOM IT 3287 197 181 1.ODO 8.0 OxO VIFx 31.2 135.0 st3 BEDROOM IT 4239 254 181 1.0D0 8.0 OxO VIFx 64.4 155.0 st4 DINING c 4705 161 209 1.000 8.0 Ox0 VIFx 20.6 115.0 st1 FOYER -A C 4692 135 209 1.000 8.0 Ox0 VIFx 42.6 135.0 st3 GREATROOM h 3292 197 157 1.000 8.0 Ox0 VIFx 82.1 175.0 st5 GREAT ROOM -A IT 3292 197 157 1.000 8.0 OxO VIFx 85.3 175.0 sty GREAT ROOM-B IT 3292 197 157 1.000 8.0 OxO - VIFx 80.4 175.0 st5 KITCHEN c 4673 14 208 1.000 8.0 0x0 VIFx 18.0 115.0 st1 •BATH IT 2560 153 128 1.000 7.0 OxO VIFx 68.3 155.0 st4 •TOILET c 333 1 15 1.000 4.0 OxO VIFx 62.2 155.0 st4 •WIC C 1488 8 66 1.000 6.0 Ox0 VIFx 80.0 175.0 st5 MASTER BEDROOM h 5371 322 189 1.000 8.0 Ox0 VIFx 80.7 175.0 st5 PANTRY c 525 3 23 1.000 5.0 Ox0 VIFx 22.4 115.0 st1 wlc2 h 1139 68 23 1.000 5.0 OxO VIFx 40.2 135.0 st3 WIc3 h 1139 68 23 1.0D0 5.0 OxO ' VIFx 67.1 155.0 st4 Trunk Htg Clg Design Veloc Diann H x W Duct Name Type (DIM) (cfm) FR (fpm) (in) (in) Material Trunk st5 PeakAVF 921 727 1.000 861 14.0 0 x 0 VinlFlx st4 st4 PeakAVF 1398 1073 1.000 1001 16.0 0 x 0 VinlFlx st3 st3 PeakAVF 1806 1542 1.000 1022 18.0 0 x 0 VinlFIx sti st1 PeakAVF 1983 1983 1.000 909 20.0 0 x 0 VinlFlx Wrightsof - 2020Jun-18 11:04:27 ZZ��.�^+�+ flight-Suile®Lbi"rse1201919.0.OBRSt108101 Pegs 1 ...1Wri9h1sofl FNACLDINOLA REVISIONS 6 18 20.rup Calc =MJB Front Door faces: W Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb2 OxO 1983 1983 0 0 0 0 Ox 0 1 VIFx * wrightsof - 292o-Jun-1911:oa:27 ," Right -Suite® Unmrsa1 W1919.0.08 RSU08101 Page ACCf\... \Wrighisofl MAC\DINOLA REVISIONS 6 18 20.rup Calc=MM Fr tDcor faces: W wrightsoft Duct System Summary AHU2 QUICK CALCS, INC. 317STLUCIE LANE, FORTPIERCE, FL34946Phone: 7724666799 Fax 772466 96 Errefl: OUICKCALCS®AOL.COM For: DINOLARESIDENCE 6000 HICKORY DRIVE, FORT PIERCE, FL34982 External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 800 cfm Job: Date: JUNE 18, 2020 By: Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O - 1.000 in/100ft 800 cfm 173 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FIR Diam (in) H x W (in)' Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH c 1136 4 52 1.000 6.0 Ox0 VIFx 35.6 135.0 st6 BEDROOM a In 3118 194 123 1.000 7.0 Ox0 VIFx 3Z8 135.0 st6 BEDROOMS h 3614 225 146 1.000 8.0 Ox0 VIFx 38.2 135.0 st6 KITCFEN2 c 3433 126 156 1.000 8.0 OxO VIFx 20.4 115.0 st2 LAUNDRY c 2148 54 98 1.000 7.0 Ox0 VIFx 20.4 115.0 st2 LIVING c 4250 135 193 1.000 8.0 0x0 VIFx 18.2 115.0 st2 WIC In 994 62 33 1.000 5.0 OxO - VIFx 24.8 115.0 st2 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st6 Peak AVF 424 320 1.000 777 10.0 0 x 0 VinlFlx st2 st2 PeakAVF 800 800 1.000 748 14.0 0 x 0 VinlFlx Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox0 1 800 800 0 0 0 0 0x 0 VIFx wrightsa - 202Wun 18 11:N 27 emt• • ,��.w�. Right -Suite® Utivemal M19 19.0.08 RS1 101 Page 3 ...LWrightsofl FMACyDINOLA REVISIONS 6 18 20,MP Calc =MJ8 Front Door faces: W