HomeMy WebLinkAboutBLOWER DOOR TEST CERTIFICATEPlan ..:.s & Development Services
Building & Code Regulation Division
2300 Virginia Ave, Rm 201
Fort Pierce, FL 34982
Phone:772-462-2165 Fa)1:772-462-6443
BLOWER DOOR TEST IFORM ' SCANNED
Giouse Infiltration Test Certification BY
Prescri(otive and Performance Method St. Lucie county
Date:
Permit #: f 4 0 (, - o 411
Contractor: r7 / r I- r (
Job address: �6 R o 71.11 1 b A -1 � 1) 1 f F� Ik4z'.e PL. 3 Y- 4 -
Construction: (Vb New Construction — Complete p ( ) Existing —After Addition
Rouse Infiltration Test Results SLC Climate Zone 2
CFM (50) = 1 0 0 1?i I
Volume = i K 3 l R Test Date: i 1 ( 9
ACH (50) =CFM (50) X GO /Volume= 3--1 Mechanical ventilation required less than 3ACH
Passing results must be & ACH (50) or less
(+/)Pass ( ) Fail
MC, Energy
The building or dwelling unit shall betested and verified as having an air leakage rate of not exceeding 7 air changes per
hour In Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a
blower door at a pressure of 0.2 Inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in
Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (1) or an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building
thermal envelope.
MC, Residential
Where the air Infiltration rate of a dwelling unit is less than 2-air changes per hour when tested with a blower door at a
Pressure of 0.2 inch W. C. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Cade, Energy Conservation
the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section NI1507.3.
Testing Company
Company Name: Pro -Duct Services Address: 1915 Rio Vista Drive, Ft. Pierce, FL 34949
I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
requirements in accordance with Spation R402.4.1.2 Climate Zone 2.
Signature:
Printed Name: Martin Klein
License/Certification #: 5061633