CUSTOMER NAME:
SITE ADDRESS:
SITE INFORMATION
5012 BIRCH DRIVE
REGENCY DKI
5012 BIRCH DRIVE
FORT PIERCE, FL 34982
SAINT LUCIE COUNTY
Know what's below.
Call before you dig.
wvvw.caI181 '1 .cgrn
APPLICABLE CODES
"ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED IN ACCORDANCE
WITH THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING
AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK
NOT CONFORMING TO THESE CODES.
1. 2017 FLORIDA BUILDING CODE, 6TH EDITION
2. 2017 FLORIDA PLUMBING CODE, 6TH EDITION
3. 2017 FLORIDA MECHANICAL CODE, 6TH EDITION
4. 2017 FLORIDA BUILDING CODE: ENERGY CONSERVATION, 6TH EDITION
5. 2014 NATIONAL ELECTRIC CODE
6. 2017 FLORIDA BUILDING CODE: EXISTING BUILDING, 6TH EDITION
C & C PRODUCT APPROVAL NUMBERS
A ~
f.... .....
St PROD. FBC PRODUCT APPROVAL FBC PRODUCT APPROVAL l PRODUCT APPROVAL
APP. PRODUCT SYM. OR MIAMI-DADE N.O.A. OR N.O.A. NUMBER EXPIRATION DATE S
' I � } __ - -- - -- --------- - - Z ----------------
PA 1 —
WAYNE DALTON SERIES 800 STEEL ROLL -UP DOOR MIAMI-DADE 18-0815.08 06/07/2022 `
PA 2 SILVER LINE BUILDING PRODUCTS
70 SERIES SING HUNG WINDOW FBC FL14911.4-R11
SHEET INDEX
SHT NOM
SHEET TITLE:
PROPERTY OWNER:
CS-1.0
TITLE SHEET
MICHAEL . •
- tv..
ltcl
BIRCH5012
FORT PIERCE, FL 34982
M i
A-1.0
EXISTING BUILDING
c
S . d
S-1.0
FOUNDATION & FRAMING PLAN
ADDRESS:
"""_ .•.
f
I
ROOF FRAMING PLAN
BIRCHSITE
5012
.s IELECTRICAL
ri
PLAN
I I
FORT PIERCE, FIL 34982
� I
`v t
vv � C
yi
k � 3 PE
P � 1
,.
•'. •0
5•
_.. ..
x 1: ,: bpi} Y,Y
F
tt.. , .: : .. ...mi 'l�.: ..: _ s..i.,: r. ..i:x .. :+. ''..:. `. ;(v .. ti•� - - �ti .. ... .....?'�.. YupF4 - ......
I
I
REVIEWED FOR
CODE COMPLIANCE
ST. LUCIE COUNTY
BOCC
FILE COPY
SCANNED
BY
St. LuCe Count
THESE DOCUMENTS CONTAIN ARCHITECTURAL SYMBOLS
USED FOR GRAPHIC PURPOSES ONLY. SIZE AND
LOCATION MAY VARY TO MEET MANUFACTURER'S
SPECIFICATIONS.
DO NOT SCALE DRAWINGS. PLEASE CONTACT DESIGNER
WITH ANY QUESTIONS REGARDING DIMENSIONS,
ENGINEERING LICENSE:
loop"'
. 'reue ,
q;
y a
Anthony m,; ray,
SERIAL #
ANTHONY T. TOMB(nRC #E?PE§04C32£7DF
DRAWING NOTICE:
THESE DOCUMENTS ARE CONFIDENTIALAND ARE THE SOLE
PROPERTY OF WHOLE HOUSE ENGINEERING LLC AND MAY
NOT BE REPRODUCED, DISSEMINATED OR REDISTRIBUTED
WITHOUT THE EXPRESS WRITTEN CONSENT OF WHOLE
HOUSE ENGINEERING LLC
ROJECT NUMBER:
791
REVISIONS: -�—
DESCRIPTION DATE BY RE
PERMIT 06/03/2019 RB -
PERMIT RESPONSE 1 07/25/2019 RB A
JI I C IVHIVIC:
5012 BIRCH DRIVE
- SITE NUMBER:
5012 BIRCH DRIVE
FORT PIERCE, FL 34982
HEET DESCRIPTION:
TITLE SHEET
PI C C I IN V IVI.3 M IC:
cs - 100
I
e
e
GENERAL NOTES
1. DO NOT SCALE THESE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER
SCALED DIMENSIONS. THE CONTRACTOR SHALL REVIEW THESE DRAWINGS IN THEIR
ENTIRETY BEFORE COMMENCING CONSTRUCTION AND SHALL ACCEPT FULL
RESPONSIBILITY FOR ANY ERRORS OR OMISSIONS NOT REPORTED IMMEDIATELY IN
WRITING TO THE WHOLE HOUSE ENGINEERING, LLC. BACKCHARGES WILL NOT BE
ACCEPTED.
2. THE GENERAL CONTRACTOR SHALL VERIFY THE BUILDING POSITION WITHIN THE
SETBACK LINES PRIOR TO COMMENCING CONSTRUCTION.
3. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO BE FAMILIARIZED WITH ALL
EXISTING CONDITIONS AS THEY ARE NOT NECESSARILY SHOWN ON THESE DRAWINGS.
4. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING LOCATIONS OF ALL
FLOOR, ROOF, AND WALL OPENINGS AND PENETRATIONS,
5. IT IS THE CONTRACTORS SOLE RESPONSIBILITY TO COORDINATE THE WORK OF ALL
TRADES, DETERMINE ERECTION PROCEDURE, AND SEQUENCE TO INSURE THE SAFETY
OF THE BUILDING, ITS COMPONENTS, AND TRADE BASE DURING CONSTRUCTION.
6. ALL DETAILS AND SECTIONS SHOWN ON THESE DRAWINGS ARE INTENDED TO BE
TYPICAL AND SHALL BE CONSTRUED TO APPLY TO ANY SIMILAR CONDITION ELSEWHERE
IN THE WORK EXCEPT WHERE A DIFFERENT DETAIL AND OR SECTION IS SHOWN,
7. BUILDER IS RESPONSIBLE FOR ADEQUATE BRACING OF STRUCTURAL OR
NON-STRUCTURAL MEMBERS DURING CONSTRUCTION.
8. IT IS THE GENERAL CONTRACTORS RESPONSIBILITY TO PROVIDE ALL NECESSARY SHOP
DRAWINGS, WINDOWS, DOORS, ETC. TO WHOLE HOUSE ENGINEERING, LLC FOR REVIEW
AND APPROVAL.
9. ALL WINDOWS AND DOORS SHALL BE CAULKED AND WEATHER STRIPPED.
10. THESE DOCUMENTS, AS INSTRUMENTS OF SERVICE, ARE THE PROPERTY OF WHOLE
HOUSE ENGINEERING, LLC, AND SHALL NOT BE USED OR REPRODUCED WITHOUT THE
EXPRESS WRITTEN CONSENT OF WHOLE HOUSE ENGINEERING, LLC.
11. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL REQUIRED BUILDING
AND TRADE PERMITS AND FOR THEIR RESPECTIVE COSTS.
12. THESE DRAWINGS ARE DIAGRAMATIC AND ARE INTENDED TO SHOW THE DESIGN INTENT
ONLY. THEY DO NOT SHOW EVERY MINOR DETAIL OF CONSTRUCTION. ALL TRADES ARE
RESPONSIBLE FOR FURNISHING COMPLETE BUILDING SYSTEMS AND ALL ITEMS THAT
WOULD NORMALLY BE CONSIDERED INCIDENTAL TO THEIR INSTALLATION.
FIBERGLASS/ASPHALT DIMENSIONAL
SHINGLES SECURED W/ (6) 1" ROOF
NAILS PER TAB SHEET INSTALL OVER
ONE LAYER OF 30# ROOF FELT PAPER
W/ MIN. 6" LAP TIN TAGGED @ 12" O.C.
INSTALL ALL ROOF PRODUCTS PER
THEIR MFG'R SPECS AND THE NOA.
2X FASCIA TO
MATCH EXISTING.
tOFFIT:TOMATCH EXISTING.
R-13 BATTEN INSULATION
A VAPOR BARRIER PER FBC R703.1.1.
VERIFY
12
4MI
R-30 BATTEN INSULATION
TRUSS BEARING
MATCH EXISTING
PRE-ENGINEERED WOOD
TRUSSES @ 24" O.C.
TRUSS CONNECTOR. SEE PLAN.
MIN. 7/16" OSB OR PLYWOOD - 2X4 FRAME WALL @ 16" O.C.
SHEATHING. ATTACH W/ 8d COMMON:
3" O.C. @ PANEL EDGES, 12" O.C. FIELD.
2X4 BLOCKING AT ALL HORIZONTAL - CONCRETE CURB @ GARAGE TO
PANEL EDGES REQ. MATCH EXISTING. DRILL AND EPDXY
INTO EXISTING FOUNDATION W/ #4
HOOKS @ 12" O.C.
1/4" TAPCON W/ 2" MIN.
EMBEDMENT @ 24" O.C. W/
2" SQUARE WASHERS. FINISH FLOOR LINE
2X4 PT BOTTOM PLATE.
EXISTING FOUNDATION ° - -
r—rs-7 —
TO REMAIN. 1=1�=III-LTI
II -• III�II�III—
A TYPICAL WALL SECTION
A-1.0 SCALE: (24X36) 1/2" = 1' 0"
N
io
N
EXTERIOR DOOR & WINDOW SCHEDULE
DESIGN PRESSURES
PRODUCT APPROVAL
MANUFACTURER
NUMBER
EXPIRATION
OPENING
PRODUCT RATED
SYM.
ITEM
LOCATION
DESIGN
DESIGN PRESSURES (PSF)
PRESSURES
POS.
NEG.
O1
SERIES 800 STEEL ROLL -UP GARAGE DOOR
GARAGE
WAYNE DALTON
SEE PLAN
+55.0
-55.0
18-0815.08
06/07/2022
O2
70 SERIES SINGLE HUNG WINDOOW
GARAGE
SILVER LINE
SEE PLAN
+62.8
-65.0
FL14911.4-R11
-
0
'v
v
fV
in
co
28'-1" 4'-3" 23'-2" 13'-6"
REVIEWS-D FOR
CODE CCrMPL1Af1AC
ST. LUCIE C ATY
1 OVERALL BUILDING gC
"'All
-1.0 SCALE: (24 X36) 1/4" = 1' 0"
FILE COPY
PLANS PREPARED BY:
WHOLE HOUSE ENGINEERING LLC
4451 St. Lucie Blvd. Suite 201
Fort Pierce, FL 34946
PHONE: 772-409-1003
COPYRIGHT 02016 WHOLE HOUSE ENGINEERING LLC
r urwrruw rvv 1 we
THESE DOCUMENTS CONTAIN ARCHITECTURAL SYMBOLS
USED FOR GRAPHIC PURPOSES ONLY. SIZE AND
LOCATION MAY VARY TO MEET MANUFACTURER'S
SPECIFICATIONS.
DO NOT SCALE DRAWINGS. PLEASE CONTACT DESIGNER
WITH ANY QUESTIONS REGARDING DIMENSIONS.
ENGINEERING LICENSE:
A
9ERIAi #
3BBCA221OOOD 00004C3287DF
ANTHONY T. TOMBO III - FL, PE #80083
VRMYYII4%J I4V 1 K,G.
THESE DOCUMENTS ARE CONFIDENTIAL AND ARE THE SOLE
PROPERTY OF WHOLE HOUSE ENGINEERING LLC AND MAY
NOT BE REPRODUCED, DISSEMINATED OR REDISTRIBUTED
WITHOUT THE EXPRESS WRITTEN CONSENT OF WHOLE
HOUSE ENGINEERING LLC
PROJECT NUMBER:
1796
REVISIONS:
DESCRIPTION
DATE
BY
RE
PERMIT
06/03/2019
RB
-
PERMIT RESPONSE 1
07/25/2019
RB
A
SITE NAME:
5012 BIRCH DRIVE
SITE NUMBER:
i 1 c rwurtc.�a:
5012 BIRCH DRIVE
FORT PIERCE, FL 34982
HEET DESCRIPTION:
EXISTING BUILDING
NOTE: CONTRACTOR TO VERIFY ALL EXISTING
CONDITIONS/BEARING HEIGHTS/ DIMENSIONS/ ETC.
SHEET NUMBER:
A - 10
a
CONCRETE NOTES
1. " ALL CONCRETE TO ATTAIN A MINIMUM ULTIMATE COMPRESSIVE STRENGTH OF 3,000 PSI IN
28 DAYS. AGGREGATES TO BE CLEAN AND WELL GRADED, 1-1/4" MAXIMUM SIZE.
CONCRETE SLUMP IS TO BE 5" MINIMUM TO 6" MAXIMUM. 2,500 PSI FOR SLABS ON GRADE &
FOUNDATIONS.
2. MINIMUM CONCRETE COVER FOR REINFORCING BARS:
STRUCTURAL PART MINIMUM COVER
FOOTINGS (CAST AGAINST SOIL)
STRUCTURAL PART MINIMUM COVER
FOOTINGS (CAST AGAINST SOIL) 3" .
SLABS (CAST AGAINST SOIL W/ VAPOR BARRIER) 1-1/2"
SLABS (ABOVE GRADE LEVEL) 3/4".
BEAMS AND COLUMNS 1-1/2"
3. REINFORCING BARS, UNLESS OTHERWISE SPECIFIED, SHALL BE NEW BILLET STEEL
MEETING A.S.T.M. A615, GRADE 60. REINFORCING BARS SHALL BE DETAILED, FABRICATED,
SUPPORTED IN FORMS AND SPACED WITH ACCESSORIES FOLLOWING THE REQUIREMENTS
OF THE "MANUAL OF STANDARD PRACTICES FOR DETAILING REINFORCED CONCRETE
STRUCTURES. (A.C.I. 318)".
4. LAP ALL REINFORCING BAR SPLICES 48 BAR DIAMETERS (UNLESS OTHERWISE NOTED). ALL
REINFORCING BARS SHALL BE SECURELY WIRED TOGETHER IN THE FORMS. TWO-WAY
MATS OF STEEL SHALL BE TIED AT ALTERNATE INTERSECTIONS BOTH WAYS, PROVIDE
CORNER BARS AT ALL CORNERS FOR ALL CONTINUOUS REINFORCING IN UNIT MASONRY #5
X V-0" (30" EACH WAY) UNLESS OTHERWISE NOTED.
5. EPDXY SHALL BE HILTI HIT-HY 200 OR APPROVED EQUIVALENT.
1
FOUNDATION PLAN
i .O
SCALE: (24X36) 3/8" = 1' 0"
FORM AND POUR NEW CURB
TO MATCH EXISTING.
FINISH FLOOR LINED
a
o
#4 REBAR @ 12" O.C. W/ 8" MIN.
a o
a
EMBEDMENT AND 6" HOOK.
d Q-
a
d EXISTING FOUNDATION
TO REMAIN.
C
CURB REPAIR DETAIL
S-1 O
3/4„ = 1, - 011
FRAMING NOTES
1. STRUCTURAL WOOD AND TIMBER FRAMING SHALL CONFORM TO THE "TIMBER
CONSTRUCTION MANUAL" AS PUBLISHED BY THE AMERICAN INSTITUTE OF TIMBER
CONSTRUCTION.
2. ALL WOOD IN CONTACT WITH MASONRY OR CONCRETE SHALL BE PRESSURE TREATED.
PROVIDE AN APPROVED MOISTURE VAPOR BARRIER BETWEEN THE CONCRETE OR OTHER
CEMENTITOUS MATERIALS AND THE WOOD AS PER CODE.
3. BUILDER SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE BRACING AND BRIDGING
USED DURING ERECTION OF TRUSSES TO PREVENT COLLAPSE OR DAMAGE.
4. DIMENSIONAL LUMBER SHALL BE SOUTHERN PINE, #2 OR BETTER AND SHALL PROVIDE
ALLOWABLE STRESS VALUES OF 1100 PSI IN BENDING FOR SINGLE MEMBER USES, 90 PSI IN
HORIZONTAL SHEAR AND SHALL HAVE A MODULUS OF ELASTICITY OF 1400 KSI OR BETTER,
AS DETERMINED BY AN APPROVED LUMBER GRADING AGENCY.
5. NON -BEARING INTERIOR PARTITIONS MAY BE CONSTRUCTED OF 25 GAUGE C-CHANNEL
TYPE STUDS AT 24" O/C WITH MATCHING TRACKS TOP AND BOTTOM, WITH 1/2" GYPSUM
DRYWALL EACH SIDE. ATTACH DRYWALL WITH 1" LONG BUGLE HEAD DRYWALL SCREWS
AT 12" O.C. MAX.
6. PROVIDE FIRE BLOCKING AT ALL CONCEALED SPACES.
7. ALL DRILLING AND NOTCHING OF STUDS SHALL BE IN ACCORDANCE WITH FBC R602.2.3. AA
DAMAGE EXTENDS BACK TO EDGE OF EXISTING WINDOW
RIFY IN FIEL
A O +26.7 O +26.7 A
29.1 29.1
HD1 HD1
REMOVE AND REPLACE FRAME WALL.
SEE DETAIL A/S-1.0.
LSTA18 STRAP AT EACH END OF HEADER, WOOD LSTA18 STRAP AT 48" O.C. MAX. BEND STRAP 3" OVERTOP
BEND STRAP 3" OVER TOP PLATE TRUSSES PLATE (FILL 9 HOLES MIN. IN HEADER & TOP PLATE)
SIMPSON SPH4 @ EACH STUD 1
(2) - 2X TOP PLATE
MSTC40 STRAP AT EACH END OF
HEADER FLUSH WITH TOP OF
TOP PLATE, HEADER, & 1ST
SUPPORTING STUD (FILL 9
HOLES IN STUD MINIMUM, FILL
ALL NAIL HOLES)
6
P.T. 2X BOTTOM PLATE
I
� I
WOOD HEADER
SEE PLAN
1/4" TAPCON W/ 2" MIN.
EMBEDMENT @ 24" O.C. MAX
W/2"SQUARE WASHERS.
a a d a a 8 a
a a
a a
A TYPICAL WALL FRAMING
S_1 Q SCALE: (24X36) 1/2" = 1' 0"
-- 2X4 STUDS @ 16" O.C.
SIMPSON DTT2Z W/ 10"
MIN. EMBEDMENT @ EAC
END OF OPENING AND
END OF EACH WALL.
SIMPSON H8 @ EA. STUD.
SPH4 CAN BE USED IN
LIEU OF H8.
LSTA18 STRAP @ CORNER
Ll
EXTEND END STUD
TO DBL. TOP PLT.
2X4 NON -LOAD BEARING
SHEARWALL. FRAMING
@ 24" O.C. MAX.
FASTEN END STUD TO HDR.
W/ TWO ROWS OF 16d
z z SINKER NAILS @ 3" O.C. TYP.
ILL!
O ID c� AC22"X36" PULL DOWN 0 ° aFASTEN SHEATHING TO
N N AIR ATTIC ACCESS o o HDR. W/ 8d NAILS IN 3"
p � + o GARAGE LLO p PATTERN AS SHOWN.
x
w
CO w
00 O z m HEADER SEE PLAN. LSTA18 STRAP
0 w 0 OPPOSITE OF SHEATHING
m )
w u�
A
FASTEN TOP PLT, TO HDR.
MSTC52 STRAP NAILED ON W/ TWO SINKER R 3" S OF 16d
C. TYP.
OPPOSITE SIDE OF SHEATHING.
PORTAL FRAME. 3 2X6 SP NO. 2
SEE DETAIL B/S-1.0 ( )
2X4 SP NO. 2 FRAMING
JAMB W/ 7/16" OSB/PLY SHEATHING
W/ 8d NAILS @ 3" O/C ALL FRAMING TYP.
REMOVE AND REINSTALL GARAGE
DOOR PER FBC R302.5.1.
AA (3) 2X4 DOUBLE 2X4 MID SPAN FULL
SP NO. 2 DEPTH BLOCKING @ 48" AND
PANEL JOINTS W/ 8d NAILS @
3" O.C. IN EACH PANEL EDGE.
.H D71 HD1 MIN. (1) 1/4" TAPCON W/ SIMPSON DTT2Z HOLDOWN
2" MIN. EMBEDMENT. W/10" EMBEDMENT.
O +27.2 2X4 PRESSURE TREATED PLATE
29.6 A O -29.6 W/ ADDITIONAL SILL PLATE
VARIES `, REVIEWED FOR
CODE COMPLIANCE
ST. LUCIE COUNTY
B BOCC
° c
2 FRAMING PLAN
5-1.0 SCALE: (24X36) 3/8" = V 0"
END
B GARAGE DOOR PORTAL FRAME FILE COPY
S_1 SCALE: (24X36) 3/4" = 1' - 0"
HEADERS
BEAM #
PLY
SIZE
TYPE
SPECIES
GRADE
HD1
2
2 X 6
SAWN LUMBER
SP
#2
HD2
2
1-3/4" X 11-7/8"
VERSA -LAM
SP
2.03100
DENOTES FLITCH BEAM W/ 1/2" PLYWOOD FASTENED BETWEEN PLIES
A\
FOR QEAM/HEADER TO STUD PACK STRAP WITH MSTC40
SEE PLAN FOR HEADERIBEAM DESIGNATION AND LOCATION LHDd
NOTE: CONTRACTOR TO VERIFY ALL EXISTING
CONDITIONS/BEARING HEIGHTS/ DIMENSIONS/ ETC.
PLANS PREPARED BY:
WHOLE HOUSE ENGINEERING LLC
4451 St. Lucie Blvd. Suite 201
Fort Pierce, FL 34946
PHONE: 772-409-1003
COPYRIGHT 02016 WHOLE HOUSE ENGINEERING LLC
1JI[f±YY1114V IYV 111i11=
THESE DOCUMENTS CONTAIN ARCHITECTURAL SYMBOLS
USED FOR GRAPHIC PURPOSES ONLY. SIZE AND
LOCATION MAY VARY TO MEET MANUFACTURER'S
SPECIFICATIONS.
DO NOT SCALE DRAWINGS. PLEASE CONTACT DESIGNER
WITH ANY QUESTIONS REGARDING DIMENSIONS.
r ENGINEERING LICENSE:
SERIAL
38 BC A221000000 GO 4C 1297 DF
ANTHONY T. TOMBO III - FL, PE #80083
DRAWING NOTICE:
THESE DOCUMENTS ARE CONFIDENTIAL AND ARE THE SOLE
PROPERTY OF WHOLE HOUSE ENGINEERING LLC AND MAY
NOT BE REPRODUCED, DISSEMINATED OR REDISTRIBUTED
WITHOUT THE EXPRESS WRITTEN CONSENT OF WHOLE
HOUSE ENGINEERING LLC
<UJtU I NUMbLK:
179
KCVISIONS:
DESCRIPTION
DATE
BY
RE
PERMIT
06/03/2019
RB
-
PERMIT RESPONSE 1
07/25/2019
RB
A
SITE NAME:
5012 BIRCH DRIVE
-- VI I L I\VIwIYLI\..
VI I L /9✓YI\LVV•
5012 BIRCH DRIVE
FORT PIERCE, FL 34982
SHEET DESCRIPTION:
FOUNDATION &
FRAMING PLAN
SHEET NUMBER:
s - 100
9
I
,
n
+
STRUCTURAL DESIGN STATEMENT
I CERTIFY THAT, TO THE BEST OF MY KNOWLEDGE AND BELIEF, THESE PLANS AND
SPECIFICATIONS HAVE BEEN DESIGNED TO COMPLY WITH THE APPLICABLE
STRUCTURAL PORTIONS OF THE BUILDING CODES.
I ALSO CERTIFY THAT THE STRUCTURAL COMPONENTS, SYSTEMS, & RELATED
ELEMENTS PROVIDE ADEQUATE RESISTANCE TO WIND LOADS AND FORCES
SPECIFIED BY THE CODES LISTED BELOW.
DESIGN PARAMETERS & ASSUMPTIONS
CODE EDITION:
® FLORIDA BUILDING CODE (AND 2017 FBC EXISTING BUILDING)
WORK CLASSIFICATION: REPAIR,
0 ASCE 7 (EXPOSURE CONDITION) B
CONSTRUCTION TYPE: VB
OCCUPANCY CLASSIFICATION: R-3
BUILDING DESIGNED AS:
❑ PARTIALLY ENCLOSED IN ENCLOSED ❑ OPEN ❑ TESTED (WIND TUNNEL)
BUILDING HEIGHT:
0 5 60FT. (ASCE 7)
❑ > 60FT. (MUST USE ASCE 7)
MEAN ROOF HEIGHT: 12'- 0".
(FOR LOW RISE BUILDING WITH SLOPED ROOFS)
RISK FACTOR: II
(DETERMINED BY BUILDING USE / OCCUPANCY,
REFR TO ASCE 7 TABLE 1.5-1)
INTERNAL PRESSURE COEFFICIENT: 0.18 .
(ENCLOSED BUILDING)
BASIC WIND VELOCITY PRESSURES:
APPROPRIATE POSITIVE / NEGATIVE PRESSURE COEFFICIENTS HAVE BEEN
APPLIED TO MAIN WIND FORCE RESISTING SYSTEM, AND BUILDING ENVELOPE
COMPONENTS AND CLADDING, AS APPLICABLE:
WIND SPEED 161 (3-SEC. GUST) BASIC VELOCITY PRESSURE 19.45 PSF
NOTE: ACTUAL DESIGN PRESSURES FOR ALL EXTERIOR WINDOWS, DOORS,
GARAGE DOORS, AND SIMILAR ENVELOPE ELEMENTS ARE INDICATED ON
CONSTRUCTION PLANS.
ROOF TRUSS LIVE LOAD
TOP CHORD LIVE LOAD: 20 PSF
BOTTOM CHORD LIVE LOAD: 0" PSF
ROOF TRUSS DEAD LOAD
TOP CHORD DEAD LOAD: 10 PSF
BOTTOM CHORD DEAD LOAD: 10 PSF
ROOF TRUSS DEAD LOAD
TO RESIST WIND UPLIFT: 10 PSF TOTAL
MINIMUM DEFLECTION CRITERIA FOR TRUSS TO BE AS FOLLOWS:
ROOF TL: U240 .
ROOF LL U360 .
MAXIMUM DEFLECTION: 1.25"
SOIL BEARING CAPACITY: 2500 PSF
PRE-ENGINEERED WOOD TRUSSES
1. THE ROOF FRAMING PLAN SHOWS LOCATION & DIRECTION OF ALL ROOF MEMBERS
(TRUSSES AND GIRDERS) AND IS SCHEMATIC IN NATURE. HOWEVER, THE SUPPORTING
SUPERSTRUCTURE HAS BEEN DESIGNED UNDER THE ASSUMPTION THAT THE FRAMING
SCHEME SHOWN WILL CLOSELY PARALLEL FINAL TRUSS AND FLOOR SYSTEM LAYOUT. FOR
INDIVIDUAL TRUSSES, SEE LAYOUT & ENGINEERING SHEETS BY TRUSS MANUFACTURER.
1 �
2. THIS FRAMING SCHEME (DIRECTION OF TRUSSES AND SLABS, MAJOR G.T. BEARING
POINTS, ETC.) CAN BE MODIFIED ONLY AFTER OBTAINING PERMISSION FROM W.H.E. WHO
MUST REVIEW PROPOSED CHANGES AND AUTHORIZE STRUCTURAL REVISIONS
ACCORDINGLY.
3. FINAL SIGNED AND SEALED ENGINEERED TRUSS AND FLOOR SYSTEM DESIGN MUST BE
SUBMITTED TO THIS OFFICE FOR REVIEW. TRUSS AND FLOOR SYSTEM DESIGNERS,MUST
PROVIDE ALL TRUSS TO TRUSS CONNECTIONS AS PART OF THE DESIGN,
4. TRUSS AND FLOOR SYSTEM MANUFACTURER SHALL SUBMIT THREE (3) COPIES OF SHOP
DRAWINGS AND ENGINEERING CALCULATIONS SIGNED AND SEALED BY A REGISTERED
ENGINEER, OF THEIR DESIGN FOR REVIEW INCLUDING TWO (2) COPIES FOR W.H.E. TO
REVIEW PRIOR TO FABRICATION. REVIEW OF SHOP DRAWINGS IS A COURTESY BY W.H.E.
AND IN NO WAY RELIEVES THE MANUFACTURER OF HIS RESPONSIBILITY TO PROVIDE A
LAYOUT THAT FULLY INTEGRATES WITH W.H.E.'S SUPERSTRUCTURE. IF THERE IS ANY `
CONFLICT OR ADDITIONAL STRUCTURE NEEDED, THE TRUSS AND FLOOR SYSTEM
COMPANY SHALL NOTIFY W.H.E. IN WRITING OF THE SPECIFIC AREAS OF CONCERN,
5. W.H.E. ACCEPTS NO RESPONSIBILITY FOR STRUCTURAL BEAMS, COLUMNS, AND FOOTINGS
UNTIL REVIEW OF APPROVED TRUSS AND FLOOR SYSTEM DRAWINGS, SIGNED AND SEALED
BY REGISTERED ENGINEER.
2X #2 SYP NAILER FASTENED TO
DOUBLE PLATE W/ 12d COMMON @ 3"
O.C. AND TO (1) ADJACENT TRUSS W/
(1) ROW OF 12d COMMON @ 3" O.C.
TRUSS BOTTOM CHORD
FASTEN TOP PLATE TO EACH OTHER
W/ (2) ROWS OF (4) 10d COMMON
BETWEEN EA. STUD.
7/16" OSB ATTACHED TO STUDS
W/ MIN, 8d COMMON @ 3" O.C.
ON EDGE, 12" O.C. IN FIELD.
2X4 #2 SYP CATS @ 12" O.C. FASTENED
TO DOUBLE PLATE W/ (4) 12d COMMON
AND TO (1) ADJACENT TRUSS W/ (3)
10d COMMON TOE NAILS.
TRUSS BOTTOM CHORD
FASTEN TOP PLATE TO EACH OTHER
W/ (2) ROWS OF (4) 10d COMMON
BETWEEN EA. STUD.
7/16" OSB ATTACHED TO STUDS
W/ MIN. 8d COMMON @ 3" O.C.
ON EDGE, 12" O.C. IN FIELD.
1. FOR TRUSS THAT IS DIRECTLY ABOVE THE WALL, FASTEN TRUSS
BOTTOM CHORD TO DOUBLE PLATE WITH 10d AT 4" O.C.
2. THIS INTERIOR SHEARWALL RUNS PARALLEL TO THE TRUSSES, THIS IS
A PREFERRED ALTERNATIVE TO FRAMING ABOVE THE PLATE LINE TO
THE ROOF DECK.
A TRUSS CONN. TO SHEARWALL
S-2. O 3/4„ = 1. - 01.
NOTE: SOFFIT SHALL MATCH EXISTING FOR ROOF VENTING
NOTE: ALL EXISTING BE
VERIFIED IN FIELD PRIOR TO FABRICATION.
VERIFY DIMENSIONS, PITCH, OVERHANG LENGTH
AND HEEL HEIGHT, ETC.
ACTUAL _ USE STAINLESS STEEL OR TRIPLE ZINC CONNECTORS FOR PRESSURE TREATED
UPLIFT 400# LUMBER (NON CCA BASED) FOR CORROSIVE PROTECTION, AND FOLLOW
REQUIRED 1 RECOMMENDATIONS OF THE PRESERVATIVE WOOD TREATER FOR USE OF
ANCHOR CONNECTORS IN CONTACT WITH THEIR BRAND OF TREATED WOOD PRODUCTS.
TRUSS CONNECTOR SCHEDULE
MARK
TYPE
REF. NO.
CONNECTION
TO TRUSS
CONNECTION
TO WALL
ALLOWABLE
UPLIFT
O
TO FRAME
SIMPSON - H3
(4) 8d COMMON
(4) 8d COMMON
400 LB
O
TO FRAME
SIMPSON - LTS16
(6) 10d COMMON
(6) 10d COMMON
660 LB
n
550#
2 DAMAGE EXTENDS BACK TO EDGE OF EXISTING WINDOW
VERIFY IN FIELD --�
22"X3
STAIR
N
V
zk
'PULL DO
TICACCE
NE
S
w
0
2
p
LL
7' 0" MAX SETBACK
4/12
N
F-
z
w
w
1
REMOVE DAMAGED ROOF TRUSSES
AND REPLACE WITH PRE-ENGINEERED
WOOD TRUSSES 24" O.C.
1 ROOF FRAMING PLAN
5-2.0 SCALE: (24X36) 3/8" = 1' 0"
a
a
z
W
O
z
w
m
0
z
In
w
REMARKS
ROOF SHEATHING NAILING ZONE (N.T.S.)
ZONE ITEM
1 NAILS AT 6" O.C. PERIMETER AND 6" O.C. FIELD
2 NAILS AT 4" O.C. PERIMETER AND 6" O.C. FIELD
NOTE: ROOF SHEATHING SHALL BE 19/32" THICK CDX PLYWOOD ROOF SHEATHING
FASTENED TO ROOF FRAMING WITH 8d RING -SHANK NAILS (PER FRC803.2.3.1)
SPACED PER ZONE DESIGNATIONS AS SHOWN ABOVE.
IrLr114a rRcrmRcv
UI\Arr11YV IYV I IIiG
THESE DOCUMENTS CONTAIN ARCHITECTURAL SYMBOLS
USED FOR GRAPHIC PURPOSES ONLY. SIZE AND
LOCATION MAY VARY TO MEET MANUFACTURER'S
SPECIFICATIONS,
DO NOT SCALE DRAWINGS. PLEASE CONTACT DESIGNER
WITH ANY QUESTIONS REGARDING DIMENSIONS.
1� GIYVIIYGGRIIYV LIli C1YaG::
36 BCA2:21604000004C1287 D, '
ANTHONY T. TOMBO III - FL, PE #80083
IJF%lAVV 1YV NU I Il,c.
THESE DOCUMENTS ARE CONFIDENTIAL AND ARE THE SOLE
PROPERTY OF WHOLE HOUSE ENGINEERING LLC AND MAY
NOT BE REPRODUCED, DISSEMINATED OR REDISTRIBUTED
WITHOUT THE EXPRESS WRITTEN CONSENT OF WHOLE
HOUSE ENGINEERING LLC
'KUJtL; I NUMI3tK:
1796
r1EVISIONS:
DESCRIPTION
DATE
BY
RE
PERMIT
06/03/2019
RB
-
PERMIT RESPONSE 1
07/25/2019
RB
A
VI 1 G IYMIrI G.
5012 BIRCH DRIVE
— JI I G I14UIr1UGR.
— VI I G /YU URGJa.
5012 BIRCH DRIVE
FORT PIERCE, FL 34982
vl1"G1 U"JI F%Ir IIVIY.
ROOF FRAMING PLAN
SHEET NUMBER:
S 2nO
NOTE: CONTRACTOR TO VERIFY ALL EXISTING
CONDITIONS/BEARING HEIGHTS/ DIMENSIONS/ ETC.
n
u
GENERAL ELECTRICAL NOTES
1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH BOTH LOCAL AND 2014 NATIONAL
ELECTRICAL CODES.
2. ELECTRICAL CONTRACTOR SHALL VERIFY ELECTRICAL PLAN, RISER DIAGRAM, AND LOADS,
AND NOTIFY THE GENERAL CONTRACTOR OF ANY ERRORS OR DESCREPANCIES PRIOR TO
INSTALLATION.
3. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH OTHER TRADES TO MAKE CERTAIN
THAT ALL AIR-CONDITIONING POWER AND CONTROL WIRING AND CONDUITS ARE IN THE
BID.
4. THE ELECTRICAL CONTRACTOR IS TO SIZE MOST BRANCH CIRCUITS; A MAXIMUM VOLTAGE
DROP OF 3% IS PERMITTED.
5. SMOKE DETECTORS SHALL BE DIRECT WIRED 120V U.L. 217 APPROVED TYPE WITH AUDIBLE
ALARM INSTALLED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND
LISTING. CARBON MONOXIDE DETECTOR(S) TO COMPLY W/ UL #2034-96.
6. ALL APPLIANCE / ELECTRICAL EQUIPMENT WILL BE PROTECTED AT NAME PLATE RATING AS
PER NEC 110.3 & 110.21.
7. At.L ELECTRICAL CIRCUITS THAT SUPPLY THE FAMILY ROOM, DINING ROOM, LIVING ROOM,
STUDY, HALLWAYS, BEDROOMS, CLOSETS, AND FOYER SHALL BE ARC -FAULT PROTECTED.
8. ALL 125 VOLT 15 & 20 AMP RECEPTACLES INSTALLED IN DWELLING UNITS SHALL BE TAMPER
RESISTANT AS PER NEC 406.11.
9. INTERSYSTEM BONDING REQUIRED AND SHALL COMPLY WITH NEC SECTION 250.94.
10. GARAGE DOOR OPENER TO BE GFI PROTECTED.
11. ALL EQUIPMENT INSTALLED OUTSIDE OR EXPOSED TO WEATHER SHALL BE NEMA TYPE 3R.
12. ALL CONDUCTORS ARE TO BE COPPER, TYPE THHN, UNLESS NOTED OTHERWISE.
13. SWITCHES SHALL BE OF STANDARD GRADE OF SILENT TYPE.
14, RECEPTACLES SHALL BE 15A AND 125V OF THE GROUND TYPE.
15. LIGHTING FIXTURES SHALL BE SELECTED BY THE OWNER. 50% OF THE LAMPS SHALL BE
HIGH EFFICACY TYPE.
16. ALL 125V 1-PHASE 15A AND 20A BATHROOM, AND EXTERIOR RECEPTACLES SHALL HAVE
GROUND FAULT INTERRUPTER (GFI) PROTECTION WITH EXTERIOR RECEPTACLES OF THE
WATERPROOF TYPE. ELECTRICAL CONTRACTOR MAY INSTALL INDIVIDUAL (GFI) IN LIEU OF
(GFI) BREAKER WITH SEPARATE CIRCUIT.
17. ARC -FAULT CIRCUIT INTERRUPTER PROTECTION: ALL 120V, SINGLE PHASE, 15 AND 20 AMP
BRANCH CIRCUITS SUPPLYING OUTLETS INSTALLED OR DEVICES IN DWELLING UNIT
KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS,
SUN ROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS, OR SIMILAR
ROOMS OR AREAS SHALL BE PROTECTED BY ANY OF THE MEANS DESCRIBED IN THE NEC
2014 210.12 (A)(1) THROUGH (6)
18. BRANCH CIRCUITS SHALL BE IN THIN WALL CONDUIT OR APPROVED ROMEX.
19. ALL FAN VENTING AND ROOF PENETRATIONS SHALL BE BY MECHANICAL CONTRACTOR.
i
n
ELECTRICAL KEY
n
ELECTRICAL KEY
SYMB.
DESCRIPTION
SINGLE POLE SWITCH
$3
THREE WAY SWITCH
O
PUSH BUTTON SWITCH
DUPLEX RECEPTACLE
d
220V OUTLET
LIGHT FIXTURE
WALL MOUNT LIGHT FIXTURE
YPc
PULL CHAIN LIGHT
4' FLOURESCENT LIGHT FIXTURE
4' FLOURESCENT
®EXH
FANMT
OMBO
EXHUAST FAN/LIGHT COMBO
e FAWLT
COMBO
CEILING FAN/LIGHT COMBO
DISCONNECT SWITCH
5q
SMOKE DETECTOR
co
CARBON MONOXIDE DETECTOR
GFI
GROUND FAULT PROTECTION
WP
WEATHERPROOF
DW
DISHWASHER
R
RANGE
B.C.
BELOW COUNTER
D
DRYER
0
0
DAMAGE EXTENDS BACK TO EDGE OF EXISTING WINDOW
VERIFY IN FIELD
REMOVE AND REPLACE
RECEPTICLES. RESTORE TO
PRE -DAMAGED CONDITION. TYP.
4'FLOURESCENT
IN ATTIC
PREWIRED GARAGE
DOOR OPENER
22"X36" ATTIC ACCESS
GFI
GARAGE
V,ATER HEATER
TO REMAIN.
REMOVE AND REPLACE LIGHTING
/ I FIXTURES. RESTORE TO
/ PRE -DAMAGED CONDITION. TYP.
I 4'FLOURESCENT I
NOTE: SOME EXISTING FIXTURES, RECEPTICLES,
AND SWTICHES MAY NOT BE DEPICTED IN THIS REMOVE AND REINSTALL PANEL..
PLAN. THE CONTRCTOR SHALL FIELD VERIFY RESTORE TO PRE -DAMAGED
LOCATIONS AND RESTORE TO PRE -DAMAGED CONDITION..
CONDITION IN ACCORDANCE WITH FBC AND NEC.
REPAIR SHALL NOT INCREASE LOAD TO PANEL,
CIRCUITS, OR SERVICE.
3
1 ELECTRICAL PLAN
E-1.0 SCALE: (24X36) 3/8" = 1' 0"
w
❑
z
U-
O
Q
<
F
w
z
It
ui
O
r
w
❑
z
O
w
co
0
z
rn
E
H/ u�
NOTE: NO HVAC COMPONENTS WERE
KNOWN TO EXIST IN DAMAGED AREA. A
u
REVIEWED FOR
CODE COMPLIANCE
ST, LUCIE COUNTY
BOCC
THESE DOCUMENTS CONTAIN ARCHITECTURAL SYMBOLS
USED FOR GRAPHIC PURPOSES ONLY, SIZE AND
LOCATION MAY VARY TO MEET MANUFACTURER'S
SPECIFICATIONS.
DO NOT SCALE DRAWINGS. PLEASE CONTACT DESIGNER
WITH ANY QUESTIONS REGARDING DIMENSIONS.
ENGINEERING LICENSE:
44-
I SERIAL #: I
3B BC A2 21 00 0000 00 4C 12.87 DF
ANTHONY T. TOMBO III - FL, PE #80083
DRAWING NOTICE:
THESE DOCUMENTS ARE CONFIDENTIAL AND ARE THE SOLE
PROPERTY OF WHOLE HOUSE ENGINEERING LLC AND MAY
NOT BE REPRODUCED, DISSEMINATED OR REDISTRIBUTED
WITHOUT THE EXPRESS WRITTEN CONSENT OF WHOLE
HOUSE ENGINEERING LLC
'KUJLU I NUMbLK:
179E
KEVISIONS:
DESCRIPTION
DATE
BY
RE
PERMIT
06/03/2019
IRS
-
PERMIT RESPONSE 1
07/25/2019
RB
A
SITE NAME:
5012 BIRCH DRIVE
11 G 1`IUIYIGGR.
SITE ADDRESS:
5012 BIRCH DRIVE
FORT PIERCE, FL 34982
SHEET DESCRIPTION:
ELECTRICAL PLAN
SHEET NUMBER:
E - 100
NOTE: CONTRACTOR TO VERIFY ALL EXISTING
CONDITIONS/BEARING HEIGHTSI DIMENSIONS/ ETC.
J
PLANS PREPARED BY:
WHOLE HOUSE ENGINEERING LLC
4451 St. Lucie Blvd. Suite 201.
Fort Pierce, FC, 34946
PHONE: 772-409-1003
COPYRIGHT 02016 WHOLE HOUSE ENGINEERING LLC
✓1\/YVYIIVV IVV III,C
THESE DOCUMENTS CONTAIN ARCHITECTURAL SYMBOLS
USED FOR GRAPHIC PURPOSES ONLY. SIZE AND
LOCATION MAY VARY TO MEET MANUFACTURER'S
SPECIFICATIONS.
DO NOT SCALE DRAWINGS. PLEASE CONTACT DESIGNER
WITH ANY QUESTIONS REGARDING DIMENSIONS.
ENGINEERING LICENSE:
Anthony Tombo
SER!A.1 Ti
313 BC A2 2100 00 00 00 4C 12 87 D'e
ANTHONY T. TOMBO III - FL, PE #80083
✓ICNYVIIVV IVV I Itr C:
THESE DOCUMENTS ARE CONFIDENTIAL AND ARE THE SOLE
PROPERTY OF WHOLE HOUSE ENGINEERING LLC AND MAY
NOT BE REPRODUCED, DISSEMINATED OR REDISTRIBUTED
WITHOUT THE EXPRESS WRITTEN CONSENT OF WHOLE
HOUSE ENGINEERING LLC
PROJECT NUMBER:
1796
REVISIONS:
DESCRIPTION I DATE BY
PERMIT RESPONSE 1
M9
2020
RA
1 USER CHANGE
RB
B
SITE NAME:
611111 PA WWII 08 I-91SM
JI I G IV V IV1OGf\.
VI I {� 11V V1\VVV.
5012 BIRCH DRIVE
FORT PIERCE, FL 349812
SHEET DESCRIPTION:
TITLE SHEET
SHEET NUMBER:
CIS - iso
r�r�rva rFXQrruccv rvR.
GENERAL NOTES
1. DO NOT SCALE THESE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER
SCALED DIMENSIONS. THE CONTRACTOR SHALL REVIEW THESE DRAWINGS IN THEIR
ENTIRETY BEFORE COMMENCING CONSTRUCTION AND SHALL ACCEPT FULL.
RESPONSIBILITY FOR ANY ERRORS OR OMISSIONS NOT REPORTED IMMEDIATELY IN
WRITING TO THE WHOLE HOUSE ENGINEERING, LLC. BACKCHARGES WILL NOT BE
ACCEPTED.
2. THE GENERAL CONTRACTOR SHALL VERIFY THE BUILDING POSITION WITHIN THE
SETBACK LINES PRIOR TO COMMENCING CONSTRUCTION.
3. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO BE FAMILIARIZED WITH ALL
EXISTING CONDITIONS AS THEY ARE NOT NECESSARILY SHOWN ON THESE DRAWINGS.
4. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING LOCATIONS OF ALL
FLOOR, ROOF, AND WALL OPENINGS AND PENETRATIONS.
5. IT IS THE CONTRACTORS SOLE RESPONSIBILITY TO COORDINATE THE WORK OF ALL
TRADES, DETERMINE ERECTION PROCEDURE, AND SEQUENCE TO INSURE THE SAFETY
OF THE BUILDING, ITS COMPONENTS, AND TRADE BASE DURING CONSTRUCTION.
6. ALL DETAILS AND SECTIONS SHOWN ON THESE DRAWINGS ARE INTENDED TO BE
TYPICAL AND SHALL BE CONSTRUED TO APPLY TO ANY SIMILAR CONDITION ELSEWHERE
IN THE WORK EXCEPT WHERE A DIFFERENT DETAIL AND OR SECTION IS SHOWN.
7. BUILDER IS RESPONSIBLE FOR ADEQUATE BRACING OF STRUCTURAL OR
NON-STRUCTURAL MEMBERS DURING CONSTRUCTION.
8. IT IS THE GENERAL CONTRACTORS RESPONSIBILITY TO PROVIDE ALL NECESSARY SHOP
DRAWINGS, WINDOWS, DOORS, ETC, TO WHOLE HOUSE ENGINEERING, LLC FOR REVIEW
AND APPROVAL.
9. ALL WINDOWS AND DOORS SHALL BE CAULKED AND WEATHER STRIPPED.
10. THESE DOCUMENTS, AS INSTRUMENTS OF SERVICE, ARE THE PROPERTY OF WHOLE
HOUSE ENGINEERING, LLC, AND SHALL NOT BE USED OR REPRODUCED WITHOUT THE
EXPRESS WRITTEN CONSENT OF WHOLE HOUSE ENGINEERING, LLC.
11. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL REQUIRED BUILDING
AND TRADE PERMITS AND FOR THEIR RESPECTIVE COSTS.
12. THESE DRAWINGS ARE DIAGRAMATIC AND ARE INTENDED TO SHOW THE DESIGN INTENT
ONLY. THEY DO NOT SHOW EVERY MINOR DETAIL OF CONSTRUCTION. ALL TRADES ARE
RESPONSIBLE FOR FURNISHING COMPLETE BUILDING SYSTEMS AND ALL ITEMS THAT
WOULD NORMALLY BE CONSIDERED INCIDENTAL TO THEIR INSTALLATION.
FIBERGLASS/ASPHALT DIMENSIONAL
SHINGLES SECURED W/ (6) 1" ROOF
NAILS PER TAB SHEET INSTALL OVER
ONE LAYER OF 30# ROOF FELT PAPER
W/ MIN. 6" LAP TIN TAGGED @ 12" O.C.
INSTALL ALL ROOF PRODUCTS PER
THEIR MFG'R SPECS AND THE NOA.
2X_ FASCIA TO
MATCH EXISTING.
19:1 71y1
SOFFIT TO MATCH EXISTING.
R-13 BATTEN INSULATION
VAPOR BARRIER PER FBC R703.1.1.
MIN. 7/16" OSB OR PLYWOOD
SHEATHING. ATTACH W/ 8d COMMON:
3" O.C. @ PANEL EDGES, 12" O.C. FIELD.
2X4 BLOCKING AT ALL HORIZONTAL
PANEL EDGES REQ.
1/4" TAPCON W/ 2" MIN.
EMBEDMENT @ 24" O.C. W/
2" SQUARE WASHERS.
2X4 PT BOTTOM PLATE.
EXISTING FOUNDATION
TO REMAIN.
12
4P w_77
a4
—I � I—�-1-
-1-I-I I
• II IIIdIL--III_I
R-30 BATTEN INSULATION L
TRUSS 31ARINGo
MATCH EXISTING
PRE-ENGINEERED WOOD
TRUSSES @ 24" O.C.
TRUSS CONNECTOR. SEE PLAN.
2X4 FRAME WALL @ 16" O.C.
CONCRETE CURB @ GARAGE TO
MATCH EXISTING. DRILL AND EPDXY
INTO EXISTING FOUNDATION W/#4
HOOKS @ 12" O.C.
TYPICAL WALL SECTION
A-1.0 SCALE: (24X36) 1/2" = V 0"
FINISH FLOOR LINE/h
Y
bo
N
EXTERIOR DOOR & WINDOW SCHEDULE
DESIGN PRESSURES
PRODUCT APPROVAL
MANUFACTURER
NUMBER
EXPIRATION
OPENING
-
PRODUCT RATED
SYM.
ITEM
LOCATION
DESIGN
DESIGN PRESSURES (PSF)
FL-16546
NE
O1
2" STEEL PAN DOORS
GARAGE
CLOPAY
SEE PLAN
+36.0
-42.0
70 SERIES SINGL U WOVD�OtA����
_� GARAG
SILVER LINE
SEE PLAN��---
t w n-, '\
28'-1"
m
4'-3"
1 OVERALL BUILDING
A-1 .0/ SCALE: (24 X36) 1/4"
23'-2"
v
v
IN
REVIEWED FOR
CODE COMPLIANCE
13'-6" —ST. LUCli= COUNTY
BOCK
File Copy
' PLANS PREPARED BY:
WHOLE HOUSE ENGINEERING LLC
4451 St. Lucie Blvd. Suite 201
Fort fierce, FL 34946
PHONE: 772-409-1003
COPYRIGHT C2016 WHOLE HOUSE ENGINEERING LLC
' DRAWING NOTICE
THESE DOCUMENTS CONTAIN ARCHITECTURAL SYMBOLS
USED FOR GRAPHIC PURPOSES ONLY. SIZE AND
LOCATION MAY VARY TO MEET MANUFACTURER'S
SPECIFICATIONS.
DO NOT SCALE DRAWINGS. PLEASE CONTACT DESIGNER
WITH ANY QUESTIONS REGARDING DIMENSIONS.
SERIAL #:
368CA221000000 GO 4C: 1287 CIF
ANTHONY T. TOMBO III - FL, PE #80083
DRAWING NOTICE:
THESE DOCUMENTS ARE CONFIDENTIAL AND ARE THE SOLE
PROPERTY OF WHOLE HOUSE ENGINEERING LLC AND MAY
NOT BE REPRODUCED, DISSEMINATED OR REDISTRIBUTED
WITHOUT THE EXPRESS WRITTEN CONSENT OF WHOLE
HOUSE ENGINEERING LLC
PROJECT NUMBER:
%9E
KtV1JIVIV3:
DESCRIPTION
DATE I BY
RE
PERMIT
06/03/2014 RB
-
PERMIT RESPONSE 1
07/25/2019
RB
A
USER CHANGE
03/03/2020,
RB
B
I
SITE NAME:
5012 BIRCH DRIVE
- SITE NUMBER:
- SITE ADDRESS:
5012 BIRCH DRIVE
FORT PIERCE, FL 34982
- SHEET DESCRIPTION:
EXISTING BUILDING
NOTE: CONTRACTOR TO VERIFY ALL EXISTING
CONDITIONS/BEARING HEIGHTS/ DIMENSIONS/ ETC.
SHEET NUMBER:
A - 120
CONCRETE NOTES
1. ALL CONCRETE TO ATTAIN A MINIMUM ULTIMATE COMPRESSIVE STRENGTH OF 31000 PSI IN
28 DAYS. AGGREGATES TO BE CLEAN AND WELL GRADED, 1-1/4" MAXIMUM SIZE.
CONCRETE SLUMP IS TO BE 5" MINIMUM TO 6" MAXIMUM. 2,500 PSI FOR SLABS ON GRADE &
FOUNDATIONS.
2. MINIMUM CONCRETE COVER FOR REINFORCING BARS:
STRUCTURAL PART MINIMUM COVER
FOOTINGS (CAST AGAINST SOIL)
STRUCTURAL PART MINIMUM COVER
FOOTINGS (CAST AGAINST SOIL) 3" .
SLABS (CAST AGAINST SOIL W/ VAPOR BARRIER) 1-1/2"
SLABS (ABOVE GRADE LEVEL) 3/4".
BEAMS AND COLUMNS 1-1/2"
3. REINFORCING BARS, UNLESS OTHERWISE SPECIFIED, SHALL BE NEW BILLET STEEL
MEETING A.S.T.M. A615, GRADE 60. REINFORCING BARS SHALL BE DETAILED, FABRICATED,
SUPPORTED IN FORMS AND SPACED WITH ACCESSORIES FOLLOWING THE REQUIREMENTS
OF THE "MANUAL OF STANDARD PRACTICES FOR DETAILING REINFORCED CONCRETE
STRUCTURES. (A.C.I. 318)".
4. LAP ALL REINFORCING BAR SPLICES 48 BAR DIAMETERS (UNLESS OTHERWISE NOTED). ALL
REINFORCING BARS SHALL BE SECURELY WIRED TOGETHER IN THE FORMS. TWO-WAY
MATS OF STEEL SHALL BE TIED AT ALTERNATE INTERSECTIONS BOTH WAYS. PROVIDE
CORNER BARS AT ALL CORNERS FOR ALL CONTINUOUS REINFORCING IN UNIT MASONRY #5
X 5'4" (30" EACH WAY) UNLESS OTHERWISE NOTED.
5. EPDXY SHALL BE HILTI HIT-HY 200 OR APPROVED EQUIVALENT.
DAMAGE EXTENDS BACK TO EDGE OF EXISTING WINDOW
VERIFY IN FIELD
3'
J 11YY VV 1 /-11YV I%LIYIV VL L IIYV 1 I I IIVIY VVI\V
TO EXTEND TO" ALONG SIDE OF GARAGE.
�1 �\ FOUNDATION PLAN
S-1.0/ SCALE: (24X36) 3/8" = 1' 0"
FORM AND POUR NEW CURB
TO MATCH EXISTING.
FINISH FI_30R LINE
#4 REBAR @ 12" O.C. W/ 8" MIN.
EMBEDMENT AND 6" HOOK.
EXISTING FOUNDATION
TO REMAIN.
C CURB REPAIR DETAIL
5-1.0 3/4"=11-0.1
a:L1 JiI I II ,NIM
1. STRUCTURAL WOOD AND TIMBER FRAMING SHALL CONFORM TO THE "TIMBER
CONSTRUCTION MANUAL" AS PUBLISHED BY THE AMERICAN INSTITUTE OF TIMBER
CONSTRUCTION.
2. ALL WOOD IN CONTACT WITH MASONRY OR CONCRETE SHALL BE PRESSURE TREATED.
PROVIDE AN APPROVED MOISTURE VAPOR BARRIER BETWEEN THE CONCRETE OR OTHER
CEMENTITOUS MATERIALS AND THE WOOD AS PER CODE.
3. BUILDER SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE BRACING AND BRIDGING
USED DURING ERECTION OF TRUSSES TO PREVENT COLLAPSE OR DAMAGE.
4. DIMENSIONAL LUMBER SHALL BE SOUTHERN PINE, #2 OR BETTER AND SHALL PROVIDE
ALLOWABLE STRESS VALUES OF 1100 PSI IN BENDING FOR SINGLE MEMBER USES, 90 PSI IN
HORIZONTAL SHEAR AND SHALL HAVE A MODULUS OF ELASTICITY OF 1400 KSI OR BETTER,
AS DETERMINED BY AN APPROVED LUMBER GRADING AGENCY.
5. NON -BEARING INTERIOR PARTITIONS MAY BE CONSTRUCTED OF 25 GAUGE C-CHANNEL
TYPE STUDS AT 24" O/C WITH MATCHING TRACKS TOP AND BOTTOM, WITH 1/2" GYPSUM
DRYWALL EACH SIDE. ATTACH DRYWALL WITH 1" LONG BUGLE HEAD DRYWALL SCREWS
AT 12" O.C. MAX.
6. PROVIDE FIRE BLOCKING AT ALL CONCEALED SPACES.
7. ALL DRILLING AND NOTCHING OF STUDS SHALL BE IN ACCORDANCE WITH FBC R602.2.3.
DAMAGE EXTENDS BACK TO EDGE OF EXISTING WINDOW
VERIFY IN FIELD
REMOVE AND REPLACE FRAME WALL.
SEE DETAIL A/S-1.0,
2X4 NON -LOAD BEARING
SHEARWALL. FRAMING
@ 24" O.C. MAX.
LSTA18 STRAP AT EACH END OF HEADER,
BEND STRAP 3" OVER TOP PLATE
SIMPSON SPH4 @ EACH STUD -
MSTC40 STRAP AT EACH END OF
HEADER FLUSH WITH TOP OF
TOP PLATE, HEADER, & 1ST
SUPPORTING STUD (FILL 9
HOLES IN STUD MINIMUM, FILL
ALL NAIL HOLES)
P.T. 2X BOTTOM PLATE
WOOD LSTA18 STRAP AT 48" O.C. MAX. BEND STRAP 3" OVERTOP
TRUSSES PLATE (FILL 9 HOLES MIN. IN HEADER & TOP PLATE)
i
(2) - 2X TOP PLATE
I
';
WOOD HEADER -
SEE PLAN 1<
1/4" TAPCON W/ 2" MIN.
EMBEDMENT @ 24" O.C. MAX
W/ 2" SQUARE WASHERS.
I
i
\ 4 a b
d
4
A TYPICAL WALL FRAMING
S_1.0 SCALE: (24X36) 1/2" = 1' 0"
Z Z - - —
w w 2
C7 � r U'w
0 CO22"X36 PULL DOWN O
o N N ` A\ STAIR ATTIC ACCESS p
N i
UL p /A = GARAGE p p /
wC0 O F- UU HEADER SEE PLAN.
v z
w U) UL! CO
W \ W
PORTAL FRAME.
SEE DETAIL B/S-1.0
EXISTING TO REMAIN
2
S-1.0
REMOVE AND REINSTALL GARAGE
DOOR PER FBC R302.5.1.
FRAMING PLAN
SCALE: (24X36) 3/8" = 1' 0"
EXISTING TO REMAIN
HEADERS
BEAM #
PLY
I SIZE
TYPE
SPECIES
GRADE
HD1
2
2 X 6
SAWN LUMBER
SP
#2
HD2
2
1-3/4" X 11-7/8"
VERSA -LAM
SP
2.03100
*_DENOTES FLITCH BEAM W/ 1/2" PLYWOOD FASTENED BETWEEN PLIES
A
FOR BEAMMEADER TO STUD PACK STRAP WITH MSTC40
SEE PLAN FOR HEADER/BEAM DESIGNATION AND LOCATION FHXI
MSTC52 STRAP NAILED ON
OPPOSITE SIDE OF SHEATHING.
JAMB
(S) 2X4
SP NO. 2
MIN. (1) 1/4" TAPCON W/
2" MIN. EMBEDMENT.
Mrs,
2X4 STUDS @ 16" O.C.
SIMPSON DTT2Z W/ 10"
MIN. EMBEDMENT @ E/
END OF OPENING AND
END OF EACH WALL.
SIMPSON H8 @ EA. STUD. I
SPH4 CAN BE USED IN
LIEU OF H8.
A\
LSTA18 STRAP @ CORNER
EXTEND END STUD
TO DBL. TOP PLT.
FASTEN END STUD TO HDR.
W/ TWO ROWS OF 16d
SINKER NAILS @ 3" O.C. TYP.
FASTEN SHEATHING TO
HDR. W/ 8d NAILS IN 3"
PATTERN AS SHOWN.
LSTA18 STRAP
OPPOSITE OF SHEATHING
FASTEN TOP PLT. TO HDR.
W/ TWO ROWS OF 16d
SINKER @ 3" O.C. TYP.
(3) 2X6 SP NO. 2
�- 2X4 SP NO. 2 FRAMING
W/ 7/16" OSB/PLY SHEATHING
W/ Bd NAILS @ 3" O/C ALL FRAMING TYP.
\- DOUBLE 2X4 MID SPAN FULL
DEPTH BLOCKING @ 48" AND
PANEL JOINTS W/ 8d NAILS @
�0
3" O.C. IN EACH PANEL EDGE.
SIMPSON DTT2Z HOLDOWN
W/10" EMBEDMENT.
REVISION
REVIEWED FOR
END CODE COMPLIANCE
ST_ LUCIE COUNTY
BOCC
GARAGE DOOR PORTAL FRAME
SCALE: (24X36) 3/4" = 1' - 0"
File Cc'
NOTE: CONTRACTOR TO VERIFY ALL EXISTING
CONDITIONS/BEARING HEIGHTS/ DIMENSIONS/ ETC.
PLANS PREPARED BY:
WHOLE HOUSE ENGINEERING LLC
4451 St. Lucie Blvd. Suite 201
Fort Pierce, FL 34946
PHONE: 772-409-1003
COPYRIGHT L2016 WHOLE HOUSE ENGINEERING LLC
r Vr��rruw Iw I l�.c
THESE DOCUMENTS CONTAIN ARCHITECTURAL SYMBOLS
USED FOR GRAPHIC PURPOSES ONLY. SIZE AND
LOCATION MAY VARY TO MEET MANUFACTURER'S
SPECIFICATIONS.
DO NOT SCALE DRAWINGS. PLEASE CONTACT DESIGNER
WITH ANY QUESTIONS REGARDING DIMENSIONS.
ENGINEERING LICENSE:
0
9ERTALa #:
3B ECA221000000004C1287DF
ANTHONY T. TOMBO III - FL, PE #80083
— VRNYYIIY l7 IYV I IIi C.
THESE DOCUMENTS ARE CONFIDENTIAL AND ARE THE SOLE
PROPERTY OF WHOLE HOUSE ENGINEERING LLC AND MAY
NOT BE REPRODUCED, DISSEMINATED OR REDISTRIBUTED
WITHOUT THE EXPRESS WRITTEN CONSENT OF WHOLE
HOUSE ENGINEERING LLC
r
PROJECT NUMBER:
y5
DESCRIPTION
DATE
BY
RE
PERMIT
06/03/2019
RB
PERMIT RESPONSE 1
07/25/2019
RB A
USER CHANGE
03/03/2020
RB B
SITE NAME:
5012 BIRCH DRIVE
— �111 G Ir VIYI�CI>.
SITE ADDRESS:
5012 BIRCH DRIVE
FORT PIERCE, FL 34982
- 0ncr- I urwa.Klr I IVIn:
FOUNDATION &
FRAMING PLAN
SHEET NUMBER:
s - 100
STRUCTURAL DESIGN STATEMENT
I CERTIFY THAT, TO THE BEST OF MY KNOWLEDGE AND BELIEF, THESE PLANS AND
SPECIFICATIONS HAVE BEEN DESIGNED TO COMPLY WITH THE APPLICABLE
STRUCTURAL PORTIONS OF THE BUILDING CODES.
I ALSO CERTIFY THAT THE STRUCTURAL COMPONENTS, SYSTEMS, & RELATED
ACTUAL
USE STAINLESS STEEL OR TRIPLE ZINC CONNECTORS FOR
PRESSURE TREATED
ELEMENTS PROVIDE ADEQUATE RESISTANCE TO WIND LOADS AND FORCES
UPLIFT
400# LUMBER (NOfJ CCA BASED) FOR CORROSIVE PROTECTION,
AND FOLLOW
SPECIFIED BY THE CODES LISTED BELOW.
I RECOMMENDATIONS OF THE PRESERVATIVE WOOD TREATER
FOR USE OF
REQUIRED
CONNECTORS IN CONTACT WITH THEIR BRAND OF TREATED
WOOD PRODUCTS.
ANCHOR
DESIGN PARAMETERS & ASSUMPTIONS
CODE EDITION:
IN FLORIDA BUILDING CODE (AND 2017 FBC EXISTING BUILDING)
WORK CLASSIFICATION: REPAIR.
® ASCE 7 (EXPOSURE CONDITION) B
CONSTRUCTION TYPE: VB
OCCUPANCY CLASSIFICATION: R-3
BUILDING DESIGNED AS:
❑ PARTIALLY ENCLOSED IN ENCLOSED ❑ OPEN ❑ TESTED (WIND TUNNEL)
BUILDING HEIGHT:
® <_ 60FT. (ASCE 7)
❑ > 60FT. (MUST USE ASCE 7)
MEAN ROOF HEIGHT: 12' - 0",
(FOR LOW RISE BUILDING WITH SLOPED ROOFS)
RISK FACTOR: II
(DETERMINED BY BUILDING USE / OCCUPANCY,
REFR TO ASCE 7 TABLE 1.5-1)
INTERNAL PRESSURE COEFFICIENT: 0.18
(ENCLOSED BUILDING)
BASIC WIND VELOCITY PRESSURES:
APPROPRIATE POSITIVE / NEGATIVE PRESSURE COEFFICIENTS HAVE BEEN
APPLIED TO MAIN WIND FORCE RESISTING SYSTEM, AND BUILDING ENVELOPE
COMPONENTS AND CLADDING, AS APPLICABLE:
WIND SPEED 161 (3-SEC. GUST) BASIC VELOCITY PRESSURE 19.45 PSF
NOTE: ACTUAL DESIGN PRESSURES FOR ALL EXTERIOR WINDOWS, DOORS,
GARAGE DOORS, AND SIMILAR ENVELOPE ELEMENTS ARE INDICATED ON
CONSTRUCTION PLANS.
ROOF TRUSS LIVE LOAD
TOP CHORD LIVE LOAD: 20 PSF
BOTTOM CHORD LIVE LOAD: 0* PSF
ROOF TRUSS DEAD LOAD
TOP CHORD DEAD LOAD:
10 PSF
BOTTOM CHORD DEAD LOAD:
10 PSF
ROOF TRUSS DEAD LOAD
TO RESIST WIND UPLIFT:
10 PSF TOTAL
MINIMUM DEFLECTION CRITERIA FOR TRUSS TO BE AS FOLLOWS:
ROOF TL:
L/240 .
ROOF LL:
U360 .
MAXIMUM DEFLECTION:
1.25"
SOIL BEARING CAPACITY:
2500 PSF
PRE-ENGINEERED WOOD TRUSSES
1. THE ROOF FRAMING PLAN SHOWS LOCATION & DIRECTION OF ALL ROOF MEMBERS
(TRUSSES AND GIRDERS) AND IS SCHEMATIC IN NATURE. HOWEVER, THE SUPPORTING
SUPERSTRUCTURE HAS BEEN DESIGNED UNDER THE ASSUMPTION THAT THE FRAMING
SCHEME SHOWN WILL CLOSELY PARALLEL FINAL TRUSS AND FLOOR SYSTEM LAYOUT. FOR
INDIVIDUAL TRUSSES, SEE LAYOUT & ENGINEERING SHEETS BY TRUSS MANUFACTURER.
2. THIS FRAMING SCHEME (DIRECTION OF TRUSSES AND SLABS, MAJOR G.T. BEARING
POINTS, ETC.) CAN BE MODIFIED ONLY AFTER OBTAINING PERMISSION FROM W.H.E. WHO
MUST REVIEW PROPOSED CHANGES AND AUTHORIZE STRUCTURAL REVISIONS
ACCORDINGLY.
3. FINAL SIGNED AND SEALED ENGINEERED TRUSS AND FLOOR SYSTEM DESIGN MUST BE
SUBMITTED TO THIS OFFICE FOR REVIEW. TRUSS AND FLOOR SYSTEM DESIGNERS MUST
PROVIDE ALL TRUSS TO TRUSS CONNECTIONS AS PART OF THE DESIGN.
4. TRUSS AND FLOOR SYSTEM MANUFACTURER SHALL SUBMIT THREE (3) COPIES OF SHOP
DRAWINGS AND ENGINEERING CALCULATIONS SIGNED AND SEALED BY A REGISTERED
ENGINEER, OF THEIR DESIGN FOR REVIEW INCLUDING TWO (2) COPIES FOR W.H.E. TO
REVIEW PRIOR TO FABRICATION. REVIEW OF SHOP DRAWINGS IS A COURTESY BY W.H.E.
AND IN NO WAY RELIEVES THE MANUFACTURER OF HIS RESPONSIBILITY TO PROVIDE A
LAYOUT THAT FULLY INTEGRATES WITH W.H.E.'S SUPERSTRUCTURE. IF THERE IS ANY
CONFLICT OR ADDITIONAL STRUCTURE NEEDED, THE TRUSS AND FLOOR SYSTEM
COMPANY SHALL NOTIFY W.H.E. IN WRITING OF THE SPECIFIC AREAS OF CONCERN.
5, W.H.E. ACCEPTS NO RESPONSIBILITY FOR STRUCTURAL BEAMS, COLUMNS, AND FOOTINGS
UNTIL REVIEW OF APPROVED TRUSS AND FLOOR SYSTEM DRAWINGS, SIGNED AND SEALED
BY REGISTERED ENGINEER.
2X #2 SYP NAILER FASTENED TO
DOUBLE PLATE W/ 12d COMMON @ 3"
O.C. AND TO (1) ADJACENT TRUSS W/
(1) ROW OF 12d COMMON @ 3" O.C.
TRUSS BOTTOM CHORD
FASTEN TOP PLATE TO EACH OTHER
W/ (2) ROWS OF (4) 10d COMMON
BETWEEN EA. STUD.
7/16" OSB ATTACHED TO STUDS
W/ MIN, 8d COMMON @ 3" O.C.
ON EDGE, 12" O.C. IN FIELD.
7 1/4" MAX
2X4 #2 SYP CATS @ 12" O.C. FASTENED
TO DOUBLE PLATE W/ (4) 12d COMMON
AND TO (1) ADJACENT TRUSS W/ (3)
10d COMMON TOE NAILS.
TRUSS BOTTOM CHORD
FASTEN TOP PLATE TO EACH OTHER
W/ (2) ROWS OF (4) 10d COMMON
BETWEEN EA. STUD.
7/16" OSB ATTACHED TO STUDS
W/ MIN. 8d COMMON @ 3" O.C.
ON EDGE, 12" O.C. IN FIELD.
1. FOR TRUSS THAT IS DIRECTLY ABOVE THE WALL, FASTEN TRUSS
BOTTOM CHORD TO DOUBLE PLATE WITH 10d AT 4" O.C.
2. THIS INTERIOR SHEARWALL RUNS PARALLEL TO THE TRUSSES. THIS IS
A PREFERRED ALTERNATIVE TO FRAMING ABOVE THE PLATE LINE TO
THE ROOF DECK.
TRUSS CONN. TO SHEARWALL
��2.0 3/4" = 1' - 0"
MARK
NOTE: SOFFIT SHALL MATCH EXISTING FOR ROOF VENTING
NOTE: ALL EXISTINbTRUSS"CONDITIO1NST0 BE
VERIFIED IN FIELD PRIOR TO FABRICATION.
VERIFY DIMENSIONS, PITCH, OVERHANG LENGTH
AND HEEL HEIGHT. ETC.
550#
i UAIVIAut: CA I CIVUJ OAL.Fl 1 u tuut: ur t7JJ 11114U VVIINUUVV
VERIFY IN FIELD
C22"X36'PULL
N
v
A
DON
TIC ACCE
i
w
<
LL
!
/
TO" MAX SETBACK —
_ 4/12
N
V
z
z
w
Ix
w
1 ROOF FRAMING PLAN
5-2.0 SCALE: (24X36) 3/8" = 1' 0"
\— REMOVE DAMAGED ROOF TRUSSES
AND REPLACE WITH PRE-ENGINEERED
WOOD TRUSSES 24" O.C.
TRUSS CONNECTOR SCHEDULE
CONNECTION (CONNECTION ALLOWABLE
TYPE REF. NO. TO TRUSS TO WALL UPLIFT REMARKS
TO FRAME I SIMPSON - H3 I (4) Bd COMMON I (4) 8d COMMON I 400 LB
TO FRAME � SIMPSON - LTS16 I (6) 10d COMMON I (6) 10d COMMON
z
w
m
O
z
z
O
w
m
z
rn
X
w
�D
660 LB
zD
REV
z
w
0
0
0
w
z
t
w
SPY
ROOF SHEATHING NAILING ZONE (N.T.S.)
ZONE
ITEM
�1
NAILS AT 6" O.C. PERIMETER AND 6" O.C. FIELD
2
NAILS AT 4" O.C. PERIMETER AND 6" O.C. FIELD
NOTE: ROOF SHEATHING SHALL BE 19132" THICK CDX PLYWOOD ROOF SHEATHING
FASTENED TO ROOF FRAMING WITH 8d RING -SHANK NAILS (PER FRC803.2.3.1)
SPACED PER ZONE DESIGNATIONS AS SHOWN ABOVE.
REVIEWED F(.,, ..
CODE COMPLIA`,.C'_
ST. LUCIE COUrj"I""%
BOCC
PLANS PREPARED BY:
WHOLE HOUSE ENGINEERING LLC
4451 St. Lucie Blvd. Suite 201
Fort fierce, FL 34946
PHONE: 772-409-1003
COPYRIGHT C2016 WHOLE HOUSE ENGINEERING LLC
Vf Vw11\V 11V 1 we
THESE DOCUMENTS CONTAIN ARCHITECTURAL SYMBOLS
USED FOR GRAPHIC PURPOSES ONLY. SIZE AND
LOCATION MAY VARY TO MEET MANUFACTURER'S
SPECIFICATIONS.
DO NOT SCALE DRAWINGS. PLEASE CONTACT DESIGNER
WITH ANY QUESTIONS REGARDING DIMENSIONS.
ENGINEERING LICENSE:
III
■ �=v6tlV■6ew..
SERIAL #:
3E. BCA222000000004Ci287DF
ANTHONY T. TOMBO III - FL. PE #80083
DRAWING NOTICE:
THESE DOCUMENTS ARE CONFIDENTIAL AND ARE THE SOLE
PROPERTY OF WHOLE HOUSE ENGINEERING LLC AND MAY
NOT BE REPRODUCED, DISSEMINATED OR REDISTRIBUTED
WITHOUT THE EXPRESS WRITTEN CONSENT OF WHOLE
HOUSE ENGINEERING LLC
PROJECT NUMBER:
1 Zq E
KtVISIUNb:
DESCRIPTION
DATE
BY
'RE
PERMIT
06103/2019
RB
j
PERMIT RESPONSE 1
07/25/2019
RB
A
USER CHANGE
03/03/2020
RB
B
I
i
011 C I14/i1Y1C:
5012 BIRCH DRIVE
a 11 C 1\VIVIG�GR.
VI I L A✓YI\LV V.
5012 BIRCH DRIVE
FORT PIERCE, FL 34982
SHEET DESCRIPTION:
ROOF FRAMING PLAN
NOTE: CONTRACTOR TO VERIFY ALL EXISTING
CONDITIONS/BEARING HEIGHTS/ DIMENSIONS/ ETC.
SHEET NUMBER:
S - 200
GENERAL ELECTRICAL NOTES
r LMI\J vmGvMmcw rVn.
1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH BOTH LOCAL AND 2014 NATIONAL
ELECTRICAL CODES.
2. ELECTRICAL CONTRACTOR SHALL VERIFY ELECTRICAL PLAN, RISER DIAGRAM, AND LOADS,
AND NOTIFY THE GENERAL CONTRACTOR OF ANY ERRORS OR DESCREPANCIES PRIOR TO
INSTALLATION.
3. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH OTHER TRADES TO MAKE CERTAIN
THAT ALL AIR-CONDITIONING POWER AND CONTROL WIRING AND CONDUITS ARE IN THE
BID.
4. THE ELECTRICAL CONTRACTOR IS TO SIZE MOST BRANCH CIRCUITS; A MAXIMUM VOLTAGE
DROP OF 3% IS PERMITTED.
5. SMOKE DETECTORS SHALL BE DIRECT WIRED 120V U.L. 217 APPROVED TYPE WITH AUDIBLE
ALARM INSTALLED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND
LISTING. CARBON MONOXIDE DETECTOR(S) TO COMPLY W/ UL #2034-96.
6. ALL APPLIANCE / ELECTRICAL EQUIPMENT WILL BE PROTECTED AT NAME PLATE RATING AS
PER NEC 110.3 & 110.21.
7. ALL ELECTRICAL CIRCUITS THAT SUPPLY THE FAMILY ROOM, DINING ROOM, LIVING ROOM,
STUDY, HALLWAYS, BEDROOMS, CLOSETS, AND FOYER SHALL BE ARC -FAULT PROTECTED,
8. ALL 125 VOLT 15 & 20 AMP RECEPTACLES INSTALLED IN DWELLING UNITS SHALL BE TAMPER
RESISTANT AS PER NEC 406.11.
9. INTERSYSTEM BONDING REQUIRED AND SHALL COMPLY WITH NEC SECTION 250.94.
10. GARAGE DOOR OPENER TO BE GFI PROTECTED.
11. ALL EQUIPMENT INSTALLED OUTSIDE OR EXPOSED TO WEATHER SHALL BE NEMA TYPE 3R.
12. ALL CONDUCTORS ARE TO BE COPPER, TYPE THHN, UNLESS NOTED OTHERWISE.
13. SWITCHES SHALL BE OF STANDARD GRADE OF SILENT TYPE.
14. RECEPTACLES SHALL BE 15A AND 125V OF THE GROUND TYPE.
15. LIGHTING FIXTURES SHALL BE SELECTED BY THE OWNER. 50% OF THE LAMPS SHALL BE
HIGH EFFICACY TYPE.
16. ALL 125V 1-PHASE 15A AND 20A BATHROOM, AND EXTERIOR RECEPTACLES SHALL HAVE
GROUND FAULT INTERRUPTER (GFI) PROTECTION WITH EXTERIOR RECEPTACLES OF THE
WATERPROOF TYPE. ELECTRICAL CONTRACTOR MAY INSTALL INDIVIDUAL (GFI) IN LIEU OF
(GFI) BREAKER WITH SEPARATE CIRCUIT.
17. ARC -FAULT CIRCUIT INTERRUPTER PROTECTION: ALL 120V, SINGLE PHASE, 15 AND 20 AMP
BRANCH CIRCUITS SUPPLYING OUTLETS INSTALLED OR DEVICES IN DWELLING UNIT
KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS,
SUN ROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS, OR SIMILAR
ROOMS OR AREAS SHALL BE PROTECTED BY ANY OF THE MEANS DESCRIBED IN THE NEC
2014 210.12 (A)(1) THROUGH (6)
18. BRANCH CIRCUITS SHALL BE IN THIN WALL CONDUIT OR APPROVED ROMEX.
19. ALL FAN VENTING AND ROOF PENETRATIONS SHALL BE BY MECHANICAL CONTRACTOR.
ELECTRICAL KEY
SYMB.
DESCRIPTION
SINGLE POLE SWITCH
3
THREE WAY SWITCH
O
PUSH BUTTON SWITCH
DUPLEX RECEPTACLE
220V OUTLET
LIGHT FIXTURE
WALL MOUNT LIGHT FIXTURE
PULL CHAIN LIGHT
4' FLOURESCENT LIGHT FIXTURE
4'PLOURESCENT
EXFF
FAN/LT
COMBO
EXHUAST FAN/LIGHT COMBO
e
COMBO
CEILING FAN/LIGHT COMBO
DISCONNECT SWITCH
sp.
SMOKE DETECTOR
CARBON MONOXIDE DETECTOR
GFI
GROUND FAULT PROTECTION
WP
WEATHERPROOF
DW
DISHWASHER
R
RANGE
B.C.
BELOW COUNTER
D
DRYER
DAMAGE EXTENDS BACK TO EDGE OF EXISTING WINDOW
VERIFY IN FIELD
� IGFI
L
REMOVE AND REPLACE
FE�GEPTICLES. RESTORE TO
PRE -DAMAGED CONDITION. TYP.
4'FLOURESCENT
IN ATTIC
PREWIRED GARAGE —\
DOOR OPENER
22"X36" ATTIC AC(
GFI
GARAGE
REMOVE AND REPLACE LIGHTING
FIXTURES. RESTORE TO
PRE -DAMAGED CONDITION. TYP.
4'FLOURESCENT
NOTE: SOME EXISTING FIXTURES, RECEPTICLES,
AND SWTICHES MAY NOT BE DEPICTED IN THIS
PLAN. THE CONTRCTOR SHALL FIELD VERIFY
LOCATIONS AND RESTORE TO PRE -DAMAGED
CONDITION IN ACCORDANCE WITH FBC AND NEC.
REPAIR SHALL NOT INCREASE LOAD TO PANEL,
CIRCUITS, OR SERVICE.
WATER HEATER
TO REMAIN.
REMOVE AND REINSTALL PANEL.
RESTORE TO PRE -DAMAGED
CONDITION.
1 ELECTRICAL PLAN
E-1.0 SCALE: (24X36) 3/8" = 1' 0"
w
0
0
LL
0
rn
z
z
ILL!
Uj
i
E H
z_
w
w
0
0
z
0
w
m
(9
z
H
U)
w
NOTE: NO HVAC COMPONENTS WERE �
KNOWN TO EXIST IN DAMAGED AREA. , {
REVISION
REVIEWED FOR
CODE COMPLIANCE
ST. LUCIE COUNTY
BOCC
File Cr
PLANS PREPARED BY:
WHOLE HOUSE ENGINEERING LLC
4451 St. Lucie Blvd. Suite 201
Fort Pierce, FL 34946
PHONE: 772-409-1003
COPYRIGHT 02016 WHOLE HOUSE ENGINEERING LLC
DRAWING NOTICE
THESE DOCUMENTS CONTAIN ARCHITECTURAL SYMBOLS
USED FOR GRAPHIC PURPOSES ONLY. SIZE AND
LOCATION MAY VARY TO MEET MANUFACTURER'S
SPECIFICATIONS.
DO NOT SCALE DRAWINGS. PLEASE CONTACT DESIGNER
WITH ANY QUESTIONS REGARDING DIMENSIONS.
ENGINEERING LICENSE:
T T
a
=SE'RIAL #:
3 B 8C A221.0000 0,0 GO.4C 1287 DF
ANTHONY T. TOMBO III - FL, PE #80083
DRAWING NOTICE:
THESE DOCUMENTS ARE CONFIDENTIAL AND ARE THE SOLE
PROPERTY OF WHOLE HOUSE ENGINEERING LLC AND MAY
NOT BE REPRODUCED, DISSEMINATED OR REDISTRIBUTED
WITHOUT THE EXPRESS WRITTEN CONSENT OF WHOLE
HOUSE ENGINEERING LLC
PROJECT NUMBER:
1796
KtVIJIUNb:
DESCRIPTION
DATE
BY
RE
PERMIT
06/03/2019
RB
PERMIT RESPONSE 1
07/25/2019
RB
A
USER CHANGE
03/03/2020
RB
B
I
SITE NAME:
5012 BIRCH DRIVE
JI 1 L I\ V It1wGn.
SITE ADDRESS:
5012 BIRCH DRIVE
FORT PIERCE, FL 34982
VI ILL. 1 v1-vvnir 1 w19.
ELECTRICAL PLAN
SHEET NUMBER.
E - 100
NOTE: CONTRACTOR TO VERIFY ALL EXISTING
CONDITIONS/BEARING HEIGHTS/ DIMENSIONS/ ETC.