Loading...
HomeMy WebLinkAboutPLANSPlumbing Plan Legend Pool — — - — — - — — Returns 1.5* Spa .......... Return 1.5" Jets 2" d) „ Skimmers 2'� e _.. _.. _.._ Vac line O 2" spa MD 2 5" Specifications 2.5" _._.1.5"._._._._,_,_._,_._._._,_,_,_._._,_._._._._._ Pool Dimensions: 16' x 40' Area: 640 Sq Ft Perimeter:1 12'LN Pool returns: 3 Vac Stub Out: Yes with Approved Vac Lock Pool Capacity Light: (3) 27 watt Savi Melody Skimmer: 2 Interior coating: Game coat . Safety ( Child Barrier ) Decking: New 1623 Sq Ft 'Concrete) . Footer: 18"x24" W2 /#5R Pump: Pentair Variable Sneed C@ 31.91 GPM Turnover Rate: 10 HR Chlorinator: Salt Filter: Pentair 200 sq ft cartridge Clean and Clear Spa 6'x6' . Hydro jets 6, returns 2. 3000 PSI qanent. (2) # 5 rebar 124" or (4) #3 `y rebar COntInUOUS Undisturbed soil underneath footer Footer Detail N.T.S. Separate Circuit far motor and light pump WPGFI 104 from water WP Manual Starter swucftl'yp) Time Clock 1 #3 Rebar 12" O.C. 9 Pump Motor i \ — L Swim In Bench Detail N.T.S. S. P.S.T. + Junction Box Toggle '�' If Savi Melody pool light used na Switch )unman box Light req�ed J-Box Ground all Metal boxes.(Ilght,motor,ecf).(Savi Melody fight niter, requires no ground) With #8 wire (sofid) Light flAures do not require ground foul interrupter Electric Diagram N.T.S. Pum p #8 Solid copper bar wire w/Apprl. Clampsfane one ea aide of p0014 total (1) #8 Bare capper wire banded to pool steel as shown EQUOPOTENTIAL BONDING DETAIL Per FL Build. Code Adaptation of N.E.C. 2008 sec680.26 Pump & Filter to be screwed down with 1.5 " long 1/8 or larger approved concrete anchors. Filter Pump & Filter Tie Down N.T.S Gel Cole aver Fiberglass Water 19,148 gallons 12' 36 deep 18" 1.5 -2" 6 PVC/ Flex I 1 Pe Bench Cross #312"D. C./ ecuan BW 1" Min ..me rd & stee coverage \ Channel Drain Ant 6^ Mir, 5-in Entrapment Thickness Min Thick floor PVC Piping In G unnite Spa X Section N.T.S. Compacted fill Wall Section Cantilever N.T.S outside angle of repaalf5n and farther-4" thick.43 REBAR @ 12" D/C each way 3 FT to 5 FT- 6" Thick w/#3 Reber@6" O/C each way 0 FT to 3 FT-8" Thick w/#3 Rebar@ 8" D/C each way 9' 5' Angle Of Repose N.T.S. "Excavation of angle of repose is allowed providing 1. Sharing is installed on excavated surfaces sufficient to securesoil tram erasion or settlement. 2.No Undermining accurs,lf undermining occurs consult a design professional. 3.Compaction test of the backfilled material are provided of C.O. of the pool. Water line 4 inch min to lens 1" sch 40 No J-Box pVC � 1.5 sch 40 PVC Needed 14 inch min 1.5" conduit No Bonding needed Light Detail SAVI MELODY N.T.S. 2-herd call TNails .099\ e'I 1/ EMB 2 16D nells� 2" x 4" Existing Wall (all Material) Existing Slab Y. ° Plywood 6 Mil Pally Moisture Barrier Shoring Detail N.T.S. in Concrete or Paver deck TYP 12" Water Level 1/ i i I I 0" Edge i -111a i Lorl.5"sch. Pump Suction Side 12 van 32' transformer 3 A Lest Trap Cover 2.5"SPx2"SOCX� 2.5 Steps N.T.S. Spa/ Pool Drain N.T.S. Skimmer Detail N.T.S. Total pool Length Typical section through POOL N.T.S. } fA I ♦ ac`r rES, PLI, (SAND rD"r 'JEERINC4hl rt i�ff,, NC F)pPI if t •._ �� ? P Th L .._.< ., _ ANSI/NSPI 3, Ai/ .I/NSPI4, ANSVNSPrl 5, ANSI/NSPI 6, :as , .. 2J ALL COINSTRUC l ION AND INSTALLATIONS TO COMPLY WITH Nil GDL RES'.0 L 1 l iAi 2)27, I+hT4:!I`TS ;, ANSt/NSPI4; ANSI/NSPAS, ANSI/NSPI 3) GUNI I E 1 H,)ih I;ETE TO BE 3000 PSI MINIMUM AT 28 DAY, 4)` ALL STE HVU I ltt GRADE 40 MINIMUM. 5) AUL Pli I G 1'1 Er ",—H 40 OR SCH 80 PVC AND INSTALL . R�EPL I l . 3 "i�lMB[NG 201v �f ALL. tDL kt D l Ll HAVI4 CONTINUOUS SOIL Bi/L i'I: �, -'OMPACTED SOIL WI rH 2000 PSF NIV I) WITH 48 GROUND WIRE PER NEC 680. :j 1`n0, NI; 1 �PF 1..8'1KON -1 NJ1, ,'PI:,r CHILD BARRIER OR SCREEN ENCLOSURE, HOUSE SAI41 a R,G(E` WITH FIRCR 4502.17.1. ALL- V/ 6 ' ND ' r r ,�i l`1t Ltl t 3F ,'L ,' II U ,I . AS 2017 (SEPARATE CONTRACTOR)_ 10) AL' EC(RtCAI aLLA iL' ,yH;,._3€I(�A ... .ICE WITH NEC 2014EDITION. 1:1; POOL MNDS':'A �E,r, 6 °. r ;>. ;LCURED ,C)"LNCRETEPAID, 12) ;,,IERCOKIIPLt I ;i, Of !'1J_ ITS> IUCTWN HOMEOWNER SHALL CONSULT `LISCENSED'POOL CONTRACTOR I:/ ORDER TO DRAIN PCIC)l IF SO DESIRED. 13,) HEAPING LQ10F J NTSHALL COMPLY LNLTH<I R 2017 John McDermott Pools By 5436 Palmetto Ave. Vitali,INC Fort Pierce. FI.34983 Do not duplicate - This drawing is the property of Pools By Vitali,INC. (Family Pools Inc) and may State Lid. CPC# 1458526 PACE DEPT. DESIGNER REV be purchased separately for $250. No duplication allowed. Vitali Bederak Scale: l" = 10 SHEET 1 OF 1 Violators may be prosecuted. PAUL WELCH INC. MECH-ELECT•CIVIL ENG. 1984 BILTMORE ST. #114 PORT SAINT LUCIE, FL 34984 PAUL WELCH P.E. FLA REG NO.29945 / �BYI St. Lucie! JUN 0 6 2019 !�1