Loading...
HomeMy WebLinkAboutPLANS�E y V V O E 41 ' —000017- J o LL N U NW g Existing Enclosed Structure w a 41' 0 Q 0 FFE is BFE of Natural Grade Property Boundary D L M Q ++ M I < LO Q N IV +- N LLJ �I r 67.8' 0 M w Lj N o w = Open Pole Barn Structure for Permit Existing Open Structure Existing Dirt Roadway a� WZ w a o� Zmm �ao ww � � Y CJ O W S Z 0 1 U C Existing Dirt Roadway L m� W LL I- N FI LE CO P LU Existing Fence Existing Dirt Roadway REVIEWED FOR 0 CODE COMPLIANCE E� ST. LUCIE COU TY cr n- BOCC a � � o GE �D )p .40 W C�•,��':�'�GENSF•'•9 ��i z J ti S 73135*: U N PROJECT N0. STATE Of ;' u 9-061 010 SHEF .�.�F. a fk fO N A1%E St. L4) 0� 2x4 Continuous Roof Batten @ 24" o.c. from Ridge to Eave 2x6 Roof Rafter @ 24" o.c. (Lean To Sections) 2x12 Header Joist on Each Side of Posts w/ (1) 2' 0 Carriage Bolt & (6) 8d Nails Thru Posts EAST / WEST SIDE VIEW 2x6 Brace on Each Side of Post w/'z" O Carriage Bolt & (3) 16d Nails @ Each End Additional 2x6 Brace Along Width of Post w/ (3) 16d Nails Each End 24" 0 x 36" Deep Isolated Concrete Footer w/ Post Base Connector (2) 2x6 Intermediate Blocking Along Headers NORTH / SOUTH SIDE VIEW Pre -Fabricated 2x4 Wood Truss Frames @ 24" o.c. (Main Frame Section) 2x4 Continuous Roof Batten @ 24" o.c. from Ridge to Eave IFlE (2) 2x12 Rafter Beam (2) 2x6 Siding Plate 12" 2x6 Spacer . im- 2x6 Rafter Fascia (2) 200 Rafter Beam 2x4 over 2x6 Siding Plate UPPER MAIN FRAME DETAIL 2x12 Header Joist (2) 2x12 Rafter Beam (2) 2x6 Siding Plate (2) 2x10 Rafter Beam (2) 2x10 Rafter Beam 2x4 over 2x6 Siding Plate 6x6 Wood Post E�3➢ Pre -Fabricated 2x4 Wood Truss Frames @ 24" o.c. /— Simpson H1 Hurricane Tie 2x6 Truss Fascia (2) 2x12 Rafter Beam w/ (2) -12 O Carriage Bolt Thru Each Post (2) 2x6 Siding Plate Simpson H1 Hurricane Tie 10 i" aZ /— 2x6 Rafter (2) 2x10 Rafter Beam w/ (2) 1"0 Carriage Bolts Thru Each Post LEAN—TO FRAME DETAIL 2x6 Rafter Simpson H1 Hurricane Tie 2x6 Truss Fascia (2) 2x10 Rafter Beam 2x6 Batten Support w/ (2) z"0 Carriage Bolts Btw. Each Post _/ Thru Each Post Fastened to Beam & Siding Batten 6x6 Wood Post 2x4 over 2x6 Siding Plate FOUNDATION —POST DETAIL 6x6 Wood Pc Simpson ABA66 Post Ba Anchored into Iso Fool 12" Min w/ 1"0 Bolt or R 24" 0 x 36" Deep Isolated Concrete Footer w/ (8) #7 Rebar & #3 Stirups @ 12" o.c. (3" Min Cover) BRACE FRAME DETAIL Pre -Fab Truss 2x6 Brace "' 0 Carriage Bolt Thru Spacers & Post 2x6 Spacer —62" 2x12 Header (2) 2x12 Rafter Beam CODE COMPLEA14CCE oc 00E n I` U V O r) E 9 J o L� N v rn N J Ill i I— u IL D Q 0 a- n - M ioW N N � � N w 0:� w O No w e a Z COm 0 N 0 o w w 2 z'0 L) v M WJ LL 0� O� U N L.L a C)f CL ii W Cl)X 1� W LL o to Z ti OUN PROJECT NO. 19-061 SHEET S-2 MAIN FRAME ROOF DETAIL 26 ga. 5V Aluminum Roof Panels 24" O.C. (2) 2x12 Rafter Beam w/ (2) '0 Carriage Bolts Thru Each Post Ridge Cap Pre -Fabricated 2x4 Wood Truss Frames @ 24" o.c. 2x4 Roof Batten 2" Drip Extention Simpson H1 Hurricane Tie 6x6 Wood Post I LEAN-TO ROOF DETAIL 2x6 Truss Fascia 3shing Gable / End Truss TRUSS BRACING DETAIL GENERAL STRUCTURAL NOTES Applicable Codes A. Construction shall be in accordance with the 6th Edition, 2017 Florida Building Code and ASCE 7-10. The above shall 2x4 Continuous Lateral govern except where other applicable codes or the construction drawings are more restrictive. Brace on Each Web Design Wind Loads A. Roofs 20 psf B. Wind 1. Basic Wind Speed 150 mph 2. Importance Factor I = 1.00 3. Class I 4. Exposure B Diagonal Bracing Nailed 5. Internal Pressure Coef. ±0.18 Truss Bottom to Opposite Side of Web Truss Bottom Cord Continuous @ 20' o.c. Cord Continuous 6. Max Design Pressure ±33.57 psf 2x4 Bracing 2x4 Bracing 48" Min Diagonal Brace Length (Top to Bottom) Each Web 3 3 3 3 WIND LOAD SCHEDULE ZONE 1 1 2 3 Pressure(+) 30.78 30.78 30.78 Suction (-) 33.57 33.57 33.57 Foundation Design A. Design of isolated and grade beam (continuous) footings is based on the allowable bearing pressure of 2500 psf (DL --3/t-"— + LL), placed on the in -situ soil or compacted fill. Pre -Fab Truss 1. Wood Trusses shall be braced and erected in accordance with the Truss Plate Institute Bracing Wood Trusses: Commentary and Recommendations , HIB-91, bracing in the Plan of Web Members: ro c I I 2. Lateral bracing (2" min) shall be continuous, 2" Drip Extention —' 3. Lateral bracing shall be restrained by diagonal bracing (2" min) at a minimum length of 4 feet. at longitudinal spacing of no more than 20 feet on center 2x6 Truss Fascia, I r 4. Each Web and Bottom Chord shall have continuous lateral bracing spaced at no more than 8 feet on center 26 ga. 5V Alurr Side P; Reinforced Concrete A. All concrete shall be in accordance to ACI 318-08. B. All concrete shall contain Type 1/II cement with a W/C >- 0.53 C. All concrete shall have a minimum compressive strength of 3,000 psi. D. Any vertical shear cold joints shall have a continuous shear keys E. All anchor bolts for bearing plates shall be placed with templates. F. All reinforcing steel shall be fabricated and placed in accordance to ACI Manual. G. All reinforcing steel shall be grade 60 ksi and in accordance to ASTM A615 H. All splices and cover protection of reinforcing steel shall be in accordance to ACI 318. Structural Wood Framing A. Studs shall be stud grade or better southern pine, mixed southern pine or hemfir. B. Rough sawn lumber shall be cut from select southern pine. C. Rough sawn lumber shall be graded by qualified agency, approved by the governing local agency code as follows: 1. Minimum allowable flexural bending stress at normal load duration shall be no less than 1500 psi 2. Minimum allowable modulus of elasticity for posts or beams shall be no less than 1,500,00 psi 3. Minimum allowable horizontal shear stress fir beams shall be no less than 90 psi. D. Bearing plates shall be treated for moisture resistance. E. Except as noted otherwise, the minimum nailing shall be as provided in Table 2304.9.1 "Fastening Schedule" of the FBC 2017 Edition. F. Headers, Beams, Battens, Plates, and Posts shall be nailed and/or bolted together securely to act as one unit. Nails shall be 16d in rows @ 12" o.c. for length of beam. All bolts shall be ¢" continuous thread with recessed nut into lumber. All post splices shall be staggered and have 4"G bolts @ 16" o.c. All post beam to post connections shall have (2) a"0 bolts. G. Provide wind anchors at supports for all roof joists and truss rafters. Anchors/Fasteners shall be Simpson brand or approved equal. H. All manufactured trussed rafters or joists shall be designed by a registered Florida Professional Engineer to support to full uniform dead and live loads and any other superimposed loads. Web arrangement and member forces shall be determined by the fabricator. Stresses shall not exceed those allowed by FBC 2017 Edition. Where hangers are required to be attached to a truss support or other framing, truss supplier shall provide adequate strength and surface area in truss elements for hanger nailing. I. All roof and wall cladding shall be 26 ga. 5V Aluminum Panels fastened with 11" hex head screws at 12" o.c. along battens and 6" o.c. along edges. Gable flashings shall be fastened with 1¢" hex head screws at 12" o.c. J. All elevation references to Above Finish Floor (AFF) or Below Finish Floor (BFF) are relevant to the finish floor elevation of the existing house structure. 0 Q 0 Li L M Q +' M � N o Q N N � N w N) n 0 rn 0 Z O o N w N c�D Z t�� U Z m m 0 O LO O 0 U v) W Z 0 U to J_ Q Q u_ O O It W O Z d W w O Verification of Construction Conditions A. Dimensions and elevations of construction are for bidding only. F_ m B. Contractor shall inspect existing conditions and verify dimensions, elevations, etc.. which affect the scope on the (� construction drawings. Contractor shall verify and construct all foundations, framing, sheathing, and roofing in LU _J accordance to all State and Local Agency codes, standards, and specifications. 6 C. The Engineer of Record shall be notified of any variations or discrepancies on the construction drawings. Any variations 0 of the constructions drawings without the Engineer of Record consent are the responsibility of the contractor and owner. 0 ° D. The construction drawings depict a finished product and all temporary bracing and means and methods of construction are the responsibility of the Contractor. MEWED FOR ra cl�L w n E COMPLIANCE E LUCIE COUNTY BOCC o ,,�14%Juurru,,,,i DZA �4 w Z J m r, 4%,, 0 ......GE %�4 0.'�.�EF•M9,'i �� 0 �,,� co N 7313 � L = * PROJECT NO. � C •: 19-Ofi 1 L 10 %9•. sTATE_9F,4 AL W