NOTICE OF ACCEPTANCE (NOA) www.miamidade.g2y/ oocmv
Wayne Dalton a Div. of Overhead Door Corporation SCANNED
3395 Addison Drive
Pensacola, FL 32514 teaVVBy�y,
SCOPE: St. Lucie u*
This NOA is being issued under the applicable Hiles and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHD (in areas other than Miami Dade County) reserve the right to have
this product or material tested for quality assurance purposes. If this product or material fails to perform in the
accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,
modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke
this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material
fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code,
including the High Velocity Hurricane Zone.
DESCRIPTION: Series 800 Steel Roll -up Door up to 22'-0" Wide with Optional Insulated Slats
APPROVAL DOCUMENT: Drawing No. 035-0036, titled "Dade County Test Doors and Approved
Modifications, Series 800 Service Door, HVHZ, +/-55 psf Design up to 22' wide X 30' High", sheets 1 and 2
of 2, dated 10/15/2007, with revision A dated 06/29/2017, prepared by the Wayne Dalton, signed and sealed
by Mark A. Sawicki, P.E., bearing the Miami -Dade County Product Control revision stamp with the Notice
of Acceptance number and expiration date by the Miami -Dade County Product Control Section.
AIISSILE IMPACT RATING: Large and Small Missile Impact Resistant
LABELING: A permanent label with the manufacturer's name or logo, manufacturing address, model
number, the positive and negative design pressure rating, indicate impact rated if applicable, installation
instruction drawing reference number, approval number (NOA), the applicable test standards, and the
statement reading `Miami -Dade County Product Control Approved' is to be located on the door's side track,
bottom angle, or inner surface of a panel.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, ase, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal ofNOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA # 17-0706.02 and consists of this page 1 and evidence pages E-1, E-2 and E-3, as
well as approval document mentioned above.
The submitted documentation was reviewed by Carlos M. Utrera, P.E.
MIAMMADE COUNTY
,.... 1
FILE COPY
elldl0/2v/-5
j .3.
P Su- -7f Ir
NOA No.18-0815.08
Expiration Date: June 7, 2022
Approval Date: September 27, 2019
Page 1
Wayne Dalton a Div. of Overhead Door Corporation
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
1. Evidence submitted under previous NOAs
A. DRAWINGS "Submitted under NOA #16-0119.05" ---
1. Drawing No. 035-0036, titled "Dade County Test Doors and Approved Modifications, Series
800 Service Door, HVHZ, +/-55 psf Design up to 22' wide X 24' High", sheets 1 and 2 of 2,
dated 10/15/2007, prepared by the Wayne Dalton, signed and sealed by David L. Monsour,
P.E. on 12/17/2015.
B. TESTS "Submitted under NOA # 12-0313.03"
1. Test reports on 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
2) Large Missile Impact Test per FBC, TAS 201-94
3) Cyclic Wind Pressure Loading per FBC, TAS 203-94
4) Tensile Test per ASTM E$
5) Forced Entry Test, per FBC, TAS 202-94
along with marked -up drawings and installation diagram of a Series/Model 822 Rolling Steel
Slat Garage Doors, prepared by Architectural Testing, Inc., Test Report No. 71156.01-109-18,
dated 03/07/2007, with Revision 2 dated 08/31/2012, signed and sealed by Michael D.
Stremmel, P.E.
C. CALCULATIONS "Submitted under NOA # 07-0416.03"
1. Calculations for attachment of guide angles to steel or concrete jamb prepared by David
Momour, P.E., dated 02/28/2007, 4 pages, signed and sealed on 03/12/2007 by David
Monsour, P.E.
D. QUALITY ASSURANCE
1. Miami -Dade Department of Regulatory and Economic Resources (RER)
E. MATERIAL CERTIFICATIONS "Submitted under NOA # 07-0416.03"
1. Test Report # 01.11850.01.418 on Self Ignition Temperature per ASTM D1929 prepared by
Southwest Research Institute, dated 02/27/2006 and signed by Karen C. Carpenter.
2. Test Report # 01.03048.01.193c on Flame Spread Index and Smoke Density Index Test per
ASTM E84 prepared by SouthWest Research Institute, dated 04/28/2000 and signed by Alex
B. Wenzel.
F. STATEMENTS "Submitted underNOA #16-0119.05"
1. Statement letter of code conformance to the 5t6 edition (2014) FBC issued by the Wayne
Dalton, dated 05/04/2016, signed and sealed by David L. Monsour, P.E.
"Submitted under NOA # 12-0313.03"
2. Statement letter of code conformance to 2010 FBC and of no financial interest, issued by the
Wayne Dalton, dated 03/08/2012, signed and sealed by David L. Monsour, P.E.
Carlos M. Utrera, P.E.
Product Control Examiner
NOA No.18-0815.08
Expiration Date: June 7, 2022
Approval Date: September 27, 2018
E-1
Wayne Dalton a Div. of Overhead Door Corporation
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
2. Evidence submitted under NOA # 17-0706.02
A. DRAWINGS
1. Drawing No. 035-0036, titled "Dade County Test Doors and Approved Modifications, Series
800 Service Door, HVHZ, +/-55 psf Design up to 22' wide X 30' High", sheets 1 and 2 of 2,
dated 10/15/2007, with revision A dated 06/29/2017, prepared by the Wayne Dalton, signed
and sealed by Mark A. Sawicki, P.E.
B. TESTS
1. Test reports on 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
2) Large Missile Impact Test per FBC, TAS 201-94
3) Cyclic Wind Pressure Loading per FBC, TAS 203-94
4) Tensile Test per ASTM E8
5) Forced Entry Test, per FBC, TAS 202-94
along with marked -up drawings and installation diagram of a Series/Model 822 Rolling Steel
Slat Garage Doors, prepared by Intertek/ATI, Test Report No. F7663.03-109-18, dated
11/14/2016, with revision dated 09/15/2017, signed and sealed by Charles L. Anderson, P.E.
C. CALCULATIONS
1. Anchor and structural calculations prepared by Wayne Dalton a Div. of Overhead Door
Corporation, dated 06/27/2017, signed and sealed by Mark A. Sawicki, P.E.
D. QUALITY ASSURANCE
1. Miami -Dade Department of Regulatory and Economic Resources (RER)
E. MATERIAL CERTIFICATIONS
1. None,
F. STATEMENTS
1. Statement letter of code conformance to the 51 edition (2014) FBC and of no financial interest
issued by the Wayne Dalton a Div. of Overhead Door Corporation, dated 06/27/2017, signed
and sealed by Mark A. Sawicki, P.E.
Y Oi/IS/Zejg
Carlos X Utrera, P.E.
Product Control Examiner
NOA No.18-0815.08
Expiration Date: June 7, 2022
Approval Date: September 27, 2018
E-2
Wayne Dalton a Div. of Overhead Door Corporation
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
3. New evidence submitted — — —
A. DRAWINGS
1. None.
B. TESTS
1. None.
C. CALCULATIONS
1. None.
D. QUALITY ASSURANCE
1. Miami -Dade Department of Regulatory and Economic Resources (RER)
E. MATERIAL CERTIFICATIONS
1. Test report on Surface Burning Characteristics Test per ASTM E84-12 on Elastopor
P1967OR Polyurethane Foam Insulation, prepared by QAI Laboratories, Test Report #
RJ1980-3, dated 07/20/2012 and signed by Greg Banasky.
F. STATEMENTS
1. Statement letter of code conformance to the 61 edition (2017) FBC issued by Wayne
Dalton, dated 08/03/2018, signed and sealed by Mark A. Sawicki, P.E.
a" J"g /fs mt5
Carlos M Utrera, P.E.-
Product Control Examiner
NOA No.18-0815.08
Expiration Date: June 7, 2022
Approval Date: September 27, 2018
E-3
I
i
w' m
0"G"R UlKLR
SU.i MN Ptt11�A CLrl
-_
nimmq row rxrvuno ___
mmn.wwur I•
MDvIM-minnl
SLAT DETAIL
m A R9 �e
0
PRODUDT REVISED
. &nDCKmmMvwllKlbilwW I
tas—I'e '� - Oa pOA.NnfB-0Dfs OB
I
n� lsq„
Sm1�6PHBSI.W® ;�\GENB�.I�/�'9 W INDLOCK DETAIL
T 610
f rC
PRODYR REVISED
eMnaw17Wae14
Mo4Mi f1d108.0]
QO't FiATE OF :��0
h
APPROYH
MARKA.tAWICVl PE FLO R619
2b13.51AiENWY IRt,SINfENIO
IEWDV61E1%>.w.V
'
oAFE
Zik'
Zox
na��F
$y4
99
�<
BfivaeF
00
u
_ypn o o_•. �?
e�
t o
n
��ascFaicF
®
F
J91
J