Loading...
HomeMy WebLinkAboutPOOL PAPERWORK,r PROJECT NAME: PROJECT ADDRESS: MCDERMOTT POOL 5436 PALMETTO AVE FORT PIERCE, FL TOTAL DYNAMIC HEAD (TDH) CALCULATION DETERMINE MAXIMUM FLOW RATE PER ANSI / ASPS -15 2013 MINIMUM FLOW RATE REQUIRED:35 gpm /SKIMMER SCANNEDBY 1 SKIMMER PER 800 ftz OF SURFACE AREA s1t• LUGie?LOU* SURFACE AREA = 640 ftz MEAN DEPTH = 3.99929822 ft POOLVOLUME = 640 ftz X 3.99929822 ft X 7.481 gal/ft3 = 19148 gal TURNOVERTIME = 10 hr X 60 min./hr = 600 min. MAXIMUM FLOW RATE = POOL VOLUME/TURNOVER = 31.9 gpm SPA FLOW RATE = 31.9 gpm MAX PIPE SIZES AT MAXIMUM SYSTEM FLOW RATE BRANCH PIPING SHALL BE N/A inch AT 6 fps MAX AT #N/A gpm TRUNK PIPING SHALL BE 2 inch AT 8 fps MAX AT 84 gpm RETURN PIPING SHALL BE 1.5 inch AT 30 fps MAX AT 63 gpm PUMP MAKE /TYPE INTELLIFLO VS 3.0 HP MAX MAIN DRAIN / COVER AQUASTAR 32 CDFL 32" V fD.i• W SIGNATUA E CONTRACTOR: VITALI BEDERAK CERT. # CPC 1458526 Sheet 1 of 3 APPROVED COVER RATE 316 gpm SIGNATURE / DATE PAUL WELCH INC. PAUL WELCH P.E. CERT# 29945 pS1ta GGGG pp,,Ole .r $� �00 y Il �f PROJECT NAME: MCDERMOTT POOL PROJECTADDRESS: 5436 PALMETTO AVE FORT PIERCE, FL TOTAL DYNAMIC HEAD (TDH) CALCULATION WORKSHEET DETERMINE MAXIMUM FLOW RATE PER ANSI / ASPS -15 2013 FRICTION LOSS FOR 2.5 inch SUCTION PIPE PER ft AT 119 gpm = 0.08 ft (PER TABLE) FRICTION LOSS FOR 1.5 inch RETURN PIPE PER ft AT 63 gpm = 0.21 ft (PER TABLE) 120 ft. SUCT. PIPE X 0.08 ftHEAD / ft = 9.6 TDH FOR SUCT. PIPE 150 ft. RETURN PIPE X 0.21 ftHEAD /ft = 31.5 TDH FOR RETURN PIPE TABLE: SMOOTH PIPE SCH 40 PVC / FLOW AND FRICTION i oss PFR FT PIPE DIAMETER (in) 6 ft/sec 8 ft/sec 10 ft/sec 1 16 gpm 0.13 1 ft 22 gpm 0.23 ft 27 gpm 0.35 ft 1.5 38 gpm 0.081 ft 51 gpm 0.14 ft 63 gpm 0.21 ft 2 63 gpm 0.06 ft 84 gpm 0.10 ft 105 gpm 0.16 ft 2.5 90 gpm 0.05 ft 119 gpm 0.08 ft 149 gpm 0.13 ft 3 138 gpm 0.04 ft 184 gpm 0.07 ft 230 gpm 0.10 ft 4 238 gpm 0.03 ft 1 317 gpm 0.05 ft 397 gpm 0.07 ft �D�• z4l 'S�E�rIIATE NTRACTOR: VITALI BEDERAK CERT. # CPC 1458526 Sheet 2 of 3 SIGNATTE / DATE PAUL W CH INC. PAUL WELCH P.E. CERT# 29945 SA- � dRA i - — PROJECT NAME: PROJECT ADDRESS: 100. 90 RO 70 0 a! 60 SO 40 0 30 f 20 10 0 MCDERMOTT POOL 5436 PALMETTO AVE FORT PIERCE, FL it .fi,.e�t #({ 11t! 7 r�tf ' I ' +r iiA z L iBi x ii!! iss f I ##'1 'y.'7 & cJT'e;c I 3 A I t � i, � � � Fa<toryPrmsec Speeds #�.. �� 31100.PM ® 2750.RPM jj b IS00 RPM e. � �11 11 S�i3I�lf I i 4 0 20 40 60 RO 100 120140 160 Flow Race in US.GPM NOTE The chuc ibwe demonmmun pmsfocmanm mums ac 4=rypmecspeeds of 7S0 RPM:I SW RPM.23S0'RPM and 3110 RPM.I—I t c,flow m<es = also be an wn pmgnrmned between the ,raaM of 400"RPM and3450 RPM as inddawd by the blue tine TDH IN PIPING: 41.1 ft FILTER LOSS IN TDH: 8.0 ft HEATER LOSS IN TDH 0.0 ft OTHER LOSSES IN TDH: 0.0 ft TOTAL SIMPLIFIED TDH: 49.1 ft NOTES: 1) PUMP OR HEATER MAKE / MODEL MAY NOT BE CHANGED 2) INSTALLATION SHALL COMPLY WITH MANUFACTURER'S INSTALLA 3) EQUIPMENT LOCATIONS MAY NOT BE CHANGED. 4) VARIABLE SPEED PUMP USE MAXIMUM FLOW IN CALCULATION. SI / D CO RA OR: VITALI BEDERAK CERT. # CPC 1458526 Sheet 3 of 3 ♦ 4 I p. INST�4 SIGNATURE / DATE PAUL WELCH INC. PAUL WELCH P.E. CERT# 29945 ®A� i To Whom It May Concern, The following is a brief overview of the technical specifications associated with Pool Barrier removable mesh fencing. Comprehensive engineering reports on the individual components and the complete structure are available upon request 1. Pool Barrier fencing is available in 4 EI and 60" heights. It is assembled in 3, 6, 9, 121 15 & 18 foot lengths. Each section is assem ed with poles placed three feet apart. 2. Our Tri-Conaim Poles are constructed ofT-6063 grade aluminum .063" thick 3. Our mesh fabric meets or exceeds all Pertinent ASTM standards 4. One end of the barrier is attached in such a manner that a tool must be used to remove it 5. An independent engineering company tested the structural integrity of our assembled fence sections. It has met or exceeded all appropriate ASTM standards, and all requirements of the Florida Building Code. 6. All in ground fittings associated with the fence are constructed of nonconductive materials. T ASTM F228M Para 4.12 directs that screws be placed no more than 6 inches apart Screws holding our moldings to poles are placed, at 5 inches apart for durability. We at Pool Barrier Inc.T°" are so sure of the quality of our fencing that it is warranted for as long as the original purchaser owns the fence. TYPICAL 15 FT. SECTION COMPRISED OF SIX 53^ POLES AMC ONE 48^ XI VBO_ SECTION OF MESH ♦ MESH IS EOGED Vfl H A TWO INCH ` I 7����i(�� PIECE OF MAW NE OVALRY BINDING. ``�-�tC �,� $ 'Y� d11�rYYifE 1' i (!{, AND SEWN WRHA MARINE QUALITY >M�)OtS---A SectionIN � THREAD. ♦ MESH IS FASTENED TO POLES WITH A PIECE OF MOLDING aiE LONG USING ZENARE SECOATED SCREWS. ® ♦ POLES ARE SET IN NON CONDUCTIVE SLEEVES APPRQX. 3^ INTO D 40 POLERT S ARE SEON 36" CENTERS {{{ ♦ FENCE IS BUILT IN 3, S. 9, 12. AND IS FOOT SECTIONS_ b� • EACH SECTION IS SET TWO TO THREE INCHES APART. T A!1 CONNECTED BY A SPRING LOADED HOOK AND EYE LATCH_ �J � p ®CP �® C R� �0 [316mml t [3 29 TECHNICAL DATA 23.4in ■ �1 Electrical Specifications Circuit Protection: Two -pole 20 AMP device at the Electrical Panel. Input: 208-230 VAC, 50160 Hz, 3200 Watts Maximum, t phase Pump Performance Curves 100 g0 80 pia 7 O 70 iv L L 60 N 50 S U 'E 40 m C p 30 R F 20 10 0 MAX SPEED 34SOR i -SPEED 4:-3UGRPM ,SPEEDS- 2350RPM�. SPEED 2-3500,RPM SPEEDY-750 RPM I. ®E 60 a0 100 120 140 160 14 Volumetric Flow Rate in US GPM I NTELLIFLOOVSF Variable Speed and Flow Pump Instaltation and User's Guide SECTION 4. TECHNICAL DATA G11o, 1),­­ 1..". rW "1 IM 130 1L 156 1W Flow Rdb (Win B. Flow Rate Table. Residential - Maximum Cartridge Flow Rates Commercial Maximum Cartridge Flaw Rates Model # Product # sq. ft. GPM GPH 1 6 hour 18 hour GPMl GPH 6 hour 8 hour CNCRP 100 160354 100 101) 6,000 36,00D 48,000 38 2,280 13.680 18,240 CNCRP150 160355 150 150 1 9,0001 54,0001 72,000 56 3,36 220,160 26,880 CNCRP200 160353 200 150 9,000 54,000 72,000 7s 4,500 27,000 36,000 (1) Recommended flow rate for residential is .5 GPM per sq. ft. (2) Commercial flow rate is a maximum of .375 GPM per sq. R of filter area NOTE: Actual system flow will depend on plumbing size and other system components. C. Replacement Parts. Item Part Number Description 1 98209800 High Flow manual air relief valve 2 53003201 Pressure Gauge .3 178548 Lid, 100 sq. ft. filter 4 176546 Lid, 150, 200 sq. ft. filter 5 59052900 Locking Ring assembly. 6 87300400 Body 0-ring 7 59016200 Air Bleed Sock Kit 8 59053700 Center Core, 100 sq. ft. filter 9 59053800 Center Core, 150, 200 sq. ft. filter 10 — R173215 Cartridge Element, 100 sq. ft. filter 11 R173216 Cartridge Element, 150 sq. ft. filter 12 R173217 Cartridge Element, 200 sq. ft. filter 13 178731 Tank Bottom 14 154712 Drain Cap Assembly 15 178732 Union Nut "C" Clip 16 U11-20OPS Union Nut 17 178746 Union Diamond Seal 18 178733 Union, Threaded Half A. Filter Pressure Loss Chart- 2 rM�MERN Es�1 Oil Mi1W(1rw=' IiGi r it r i 1 3,4 .5 10, 11, 12 3 18 SAVE THESE INSTRUCTIONS! 7