HomeMy WebLinkAboutREVIEW COMMENTSPlanning & Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL 34982
Phone:(7721462.2172 Fax:(772(462.6443
PROPERTY INFORMATION
Address: 2358 S Brocksmith Rd
City / State / Zip: Fort Pierce, FI 34945
Parcel #: 2320-501-0012-000/4
REVIEMIENTS
St. Lucie County
Page 1
Owner(s):
Shawn Sparks
Jurisdiction: SAINT LUCIE COUNTY
Zoning: AG-5 Lot#: 12
APPLICATION INFORMATION
Permit Number: 1906-0611 Stories:
Permit Type: BUILDING RESIDENTIAL RENOVATION
Block: 1
Automatic Sprinkler System? No
Contractor Name:
Shawn C Sparks
Fax Number:
Business Name:
Sparks Contractor Services Lie
Email: Scs@Sparkscontracotrservi
Business Addr:
8711 Jay Gardens
ces.Com
City / State / Zip:
Fort Pierce, FI 34945
REVIEWS AND COMMENTS
Review Type
Status Reviewed By Date Started Date Completed Date Released
DOCUMENTS MISSING
PENDING Deanna Givens 6127/2019
612712019
Comment: NOC WILL EXPIRE ON 08/24/19. NEED NEW NOC.
6/27/2019
Comment: ROOF SUB AGREEMENT
G127/2019
Comment: 2 NEED ENERGY CALC WITH SIGNATURES
FRONT COUNTER REVIEW COMPLETE Deanna Givens 6/2712019
612712019 6127/2019
Comment:
PLANS EXAMINER REVIEW INCOMPLETE William Durden 7/3/2019
Comment: • PLEASE FURNISH THE MANUFACTURES TRUSS PLACEMENT DRAWINGS IN DUPLICATE REVIEWED AND
7/5/2019 APPROVED BY THE DESIGN PERSON OF RECORD IN ACCORDANCE WITH CHAPTER 8 SECTION R802
SUBSECTION R802.1.7.1 OF THE 2017 FLORIDA RESIDENTIAL BUILDING CODE.
7/5/2019 Comment: • PLEASE FURNISH TRUSS ENGINEERING IN DUPLICATE PER 107.2.1 OF THE 2017 FLORIDA BUILDING
CODE.
Comment: • PLEASE FURNISH ENERGY CALULATIONS AND MANUAL J IN ACCORDANCE WITH SECTIONS 402 AND 403
7/5/2019 OF THE 2017 FLORIDA ENERGY CODE. NOTE ONLY, ENERGIES MUST HAVE ORIGINAL SIGNATURE OF
PREPARER
7/5/2019 Comment: MULTIPLE ROOF UNDERLAYMENT SUBMITTED WITH THE PERMIT PACKAGE. PLEASE CLARIFY. SEE
CHAPTER 1 SECTION 107 OF THE 2017 FLORIDA BUILDING.
7/5/2019 Comment: PLANS CALL OUT 5V METAL ROOFING, SUBMITTED PRODUCT APPROVAL IS FOR STANDING SEAM METAL
ROOF. PLEASE CORRECT AND RESUBMIT. SEE CHAPTER 1 SECTION 107 OF THE 2017 FLORIDA BUILDING.
Comment: • PLEASE ADD THE CUBIC VOLUME OF THE CONDITIONED SPACE TO INFORMATION BLOCK CONTAINING
THE SQUARE FOOT INFORMATION OR A LETTER FROM THE DESIGN PROFESSIONAL SPECIFYING THE
7/5/2019 CUBIC VOLUME OF -THE CONDITIONED SPACE. SEE CHAPTER 1 SECTION 107 OF THE 2017 FLORIDA
BUILDING CODE. THE INFORMATION IS NEEDED FOR THE REQUIRED BLOWER DOOR TESTING PER
SECTION 402.4.1.2 OF THE 2017 FLORIDA ENERGY CODE.
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL 34962
Phone:(772)462.2172 Fax:(772(462.6"3
REVIEW COMMENTS
Comment: THE DESIGN CRITERIA CALLS OUT THE 2017 FLORIDA BUILDING CODE. PLEASE CORRECT THE DESIGN
CRITERIA TO REFLECT THE 2017 FLORIDA EXISTING BUILDING CODE, AND THE 2017 CODES FOR THE
7/5/2019 M.E.P'S. • PLEASE ADD THE CUBIC VOLUME OF THE CONDITIONED SPACE TO INFORMATION BLOCK
CONTAINING THE SQUARE FOOT INFORMATION OR A LETTER FROM THE DESIGN PROFESSIONAL
SPECIFYING THE CUBIC VOLUME OF THE CONDITIONED SPACE. SEE CHAPTER 1 SECTION 107 OF THE
2017 FLORIDA BUILDING CODE.
7/5/2019 Comment: PLEASE SEE CHAPTER 3, SECTION 301, SUB SECTIONS 301.1.1, 301.1.2, 301.1.3 OF THE EXISTING BUILDING
CODE. PLEASE CALL OUT THE COMPLIANCE METHOD ON THE PLANS.
7/5/2019 Comment: PLEASE SEE CHAPTER 5 OF THE 2017 FLORIDA EXISTING BUILDING CODE. PLEASE CALL OUT THE
CLASSIFICATION OF WORK ON THE PLANS.
7/1012019 Comment: NO CONCRETE REPAIR DETAIL SHOWN ON THE PLANS FOR THE RELOCATION OF THE PLUMBING. SEE
SECTION 107 OF THE 2017 FLORIDA BULDING CODE.
Comment: PLANS SPECIFY SEE SPECS FOR FOUNDATION. NO INFORMATION ON THE PLANS FOR THE CONCRETE
7/1012019 PSI, TERMITE TREATMENT, ETC. PLEASE ADD THE INFORMATION/SPECS TO THE PLANS FOR THE
FOUNDATION. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE.
Comment: R503.1.1.1 OF THE 2017 EXISTING BUILDING CODE. REPLACEMENT FENESTRATION. WHERE SOME OR ALL
OF AN EXISTING FENESTRATION UNIT IS REPLACED WITH A NEW FENESTRATION PRODUCT, INCLUDING
SASH AND GLAZING,
7/10/2019 THE REPLACEMENT FENESTRATION UNIT SHALL MEET THE APPLICABLE REQUIREMENTS FOR U-FACTOR
AND SHGC AS PROVIDED IN TABLE R402.1.2.
PLEASE SUBMIT THE NFRC SHEETS SHOWING THE NEW FENESTRATION MEETING THE REQUIREMENTS
OF R503.1.1.1 OF THE 2017 FLORIDA ENERGY BUILDING CODE.
Comment: PLEASE SHOW ON THE PLANS THAT THE NEW MECHANICAL SYSTEM MEETS OR EXCEEDS SECTION
7/1012019 R503.1.2 OF THE 2017 FLORIDA ENERGY BUILDING CODE. HEATING AND COOLING SYSTEMS. NEW
HEATING, COOLING AND DUCT SYSTEMS THAT ARE PART OF THE ALTERATION SHALL COMPLY WITH
SECTIONS R403.1, R403.2, R403.3 AND R403.6.
7/10/2019 Comment: PLEASE SHOW ON THE ELECTRICAL PAGE THAT THE NEW LIGHTING COMPLIES WITH SECTION R404.1 OF
THE 2017 FLORIDA ENERGY BUILDING CODE.
7/10/2019
Comment:
PLEASE SHOW ON THE PLANS THAT THE CHANGE IN CONDITIONED SPACE MEETS OR EXCEEDS THE
MINIMUM REQUIREMENTS OF R503.2 OF THE 2017 FLORIDA ENERGY CODE.
Comment:
• COULD NOT COMPLETE MY REVIEW DUE TO INCORRECT AND MISSING INFORMATION. ONCE THE
7/10/2019
INFORMATION IS ADDED TO THE PLANS FROM THE 2017 EXISTING BUILDING CODE, I WILL BE ABLE TO
COMPLETE THE REVIEW.
ZONING REVIEW
INCOMPLETE Angela Huff 71312019
Comment:
THE SURVEYS PROVIDED ARE NOT COMPLETE. PLEASE PROVIDE 2 SURVEYS SHOWING THE
FOLLOWING INFORMATION:
71312019
*THE FINISHED FLOOR OF THE HOUSE AS WELL AS THE ADDITION.
,
*THE ELEVATION OF THE CENTERLINE OF THE ADJACENT ROAD.
*DIMENSIONS OF THE COVERED ENTRY.
7/3/2019
Comment:
PLEASE SHOW DIMENSIONS OF THE PROPOSED WORK ON THE BUILDING PLANS.
7/312019
Comment:
THE PLAN REVIEWER MAY HAVE ADDITIONAL COMMENTS.