PRODUCT EVALUATION REPORT
5V Crimp Panel
State of Florida Professional Engineer:
Terrence E. Wolfe, P.E. # 44923
2405-a S. Houston Ave., Suite 500
Humble, TX 77396
State of Flerld®
QOJ6
dP 26778
,�yq0 one naeas�a
NS•
r ;4 • m
r �e t`- ' • e
&P1'42017
Manufacturer:
MBCI, L.P. a division of NCI, L.P
Houston
14031 West Hardy
Houston, TX 77064
Lubbock
5711 FM-40
Lubbock, TX 79401
Oklahoma City
7000 S. Eastern Ave.
Oklahoma City, OK 73149
Atlanta
2280 Monier Ave.
Lilhia Springs, GA 30122
Indianapolis
1780 McCall Drive
Shelbyville, IN 46176
Memphis
300 Highway 51 North
Hernando, MS 38632
Rome
6168 State Route 233
Rome, NY 13440
Adel
1600 Rogers Road
Adel, GA 31620
Phoenix
660 South 91ift street
Tolleson, AZ 85353
Salt Lake City
1155 West 2300 North
Sall Lake City, UT 84116
Atwater
550 Industry Way
Atwater, CA 95301
SUBJECT:
Roofing, Metal Roofing
DESCRIPTION:
5V-Crimp Panel — a 24", wide, through -fastened, nonstructural, metal roof panel,
available in 26-ga. (.019). 5V-Crimp Panel is typically applied over plywood. 5V-
Crimp panel is through -fastened roof system.
CODE CRITERIA:
PER RULE 61G20-3, CHAPTER 15, FLORIDA BUILDING CODE — BUILDING, 6TH
EDITION (2017), ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
SECTION 1504
PERFORMANCE REQUIREMENTS
1604.1 Wind resistance of roofs. Roof decks and roof coverings shall be designed for
wind loads in accordance with Chapter 16, Sections 1504.3.2.
1604.3.2 Metal panel roof systems. Metal panel roof systems through fastened or
standing seam shall be tested in accordance with UL580 or ASTM E 1592 or TAS 125.
Exception: Metal roofs constructed of cold -formed steel, where the roof deck acts as the
roof covering and provides both weather protection and support for structural loads, shall
be permitted to be designed and tested with accordance with the applicable reference
structural design standard in section 2210.1
1604.7 Impact Resistance. Roof coverings installed on low -slope roofs(roofs
slope<2:12) in accordance with Section 1507 shall resist impact damage based on the
results of tests conducted in accordance with ASTM D 3746, ASTM D 4272, CGSB 37-
GP-52M or the 'Resistance to Foot Traffic" in Section 5.5 of FM 4470. All Structural metal
roofing systems having a thickness equal or greater that 22 gage and all nonstructural
metal roof systems having a thickness equal to or greater than 26 gage shall be exempt
from test listed above.
SECTION 1505
FIRE CLASSIFICATION
1505.1 General. Roof assemblies shall be divided into the classed defined below. Class
A, B, and C roof assemblies and roof coverings required to be listed byjhisesa+jion shall
be tested in accordance with ASTM E 108 or UL 790. ,CE E. ice/ o9s oa'r�ea
ii r-N v • �T i 02ma °
o % e
No.44923
STr
+ems •��� F Cj� J
asa ONAt.�'°y
0Irro"9/
W? 14 2DI7
SECTION 1506
MATERIALS
1506.1 Scope. The requirements set forth in this section shall apply to the application of
roof -covering materials specified herein. Roof coverings shall be applied in accordance
with this chapter and the manufacturer's installation instructions.
See attached installation details.
1506.3 Product identification. Roof covering materials shall be delivered in packages
bearing the manufacturer's identifying marks and approved testing agency labels required
in accordance with 1505.
1506.6 Screws. Wood Screws shall conform to ANSIfASME B 18.6.1. Screws shall be
corrosion resistant by coating, galvanization, stainless steel, nonferrous metal or suitable
corrosion -resistant material. Corrosion resistance shall be equivalent to ASTM A641,
Classl; TAS114, App E; or exhibit not more than 5 percent rust after 1000 hrs. exposure
ASTM B 117.
SECTION 1507
REQUIREMENTS FOR ROOF COVERINGS
1507.1 Scope. Roof coverings shall be applied in accordance with the applicable
provisions of this section and the manufacturer's installation instructions.
1507.1.1. Underlayment. Underlayment shall be applied and attached in accordance
with Table 1507.1.1.
1507.4 Metal roof panels. The installation of metal roof panels shall comply with the
provisions of this section.
1507.4.1 Deck requirements. Metal roof panel roof coverings shall be applied to a solid
or closely fitted deck, except where the roof covering is specifically designed to be applied
to spaced supports.
See attached limits of use.
1507.4.2 Deck slope. The minimum slope for lapped, nonsoldered seam metal roof
panels with applied lap sealant shall be one-half unit vertical in 12 units horizontal (4-
percent slope).
See attached limits of use Wo01F9cdda
c.aa.
CSygDR dR��.F3 d2677,8
;r r
'pt`R�"'t�'•3� H M 0
,0" l�AL �p L6p�sa
4d:6446q�
'142017
1507.4.3 Material standards. Metal -sheet roof covering systems that incorporate
supporting structural members shall be designed in accordance with Chapter 22. Metal -
sheet roof coverings installed over structural decking shall comply with Table 1507.4.3(2).
Table 1507.4.3 2 Metal Roof Coverings
Roof Covering Type
Minimum Application Rate
55% Aluminum -Zinc Alloy Coated Steel
ASTM A 792 AZ 50
5% Aluminum Alloy Coated Steel
ASTM A 875 GF60
Galvanized Steel
ASTM A 653G-90
Prepainted Steel
ASTM A 755
1507.4.4 Attachment. Metal roof panels shall be secured to the supports in accordance
with the manufacturer's fasteners. In absence of manufacturer recommendations, the
following fasteners shall be used.
1. Galvanized fasteners shall be used for steel roofs.
2. Copper, brass, bronze, copper alloy or 300 series stainless -steel fasteners shall be
used for copper roofs.
3. Aluminum -zinc coated fasteners are acceptable for aluminum -zinc coated roofs.
4. Stainless -steel fasteners are acceptable for all types of metal roofs.
CHAPTER22
STEEL
SECTION 2210
COLD -FORMED STEEL CONSTRUCTION
2210.1 Regular cold -formed steel. The design of cold -formed carbon and low -alloy
steel structural members shall be in accordance AISI S100.
0 9HHd PAova 01MYDfIA7
8E s��FA C.OJL
e .`.,09V` rE E. i 0MG
Nc.44'923
e � • :a:j � Si' .
o o>z1�`
S0B 1 VA4
8\ggip�4
SEP1'42017
LIMITATIONS OF USE FOR NON -HIGH VELOCITY HURRICANE ZONES
Minimum Slope:
Deck Type:
Deck Description:
Deck Attachment:
Underlayment:
Fire Barrier:
Minimum Deck Thickness:
3:12 (per manufacturer's recommendation).
Wood
19/32" or greater plywood or wood plank.
Applied in accordance with FBC 6ch Edition (2017)
Applied in accordance with FBC 6ch Edition (2017)
Class A fire exposure rating in accordance with FBC
Section 1505.1 with UL 790.
15/32"-For Reroof Only (19/32" for New
Construction)
Documentation Supporting the Compliance Statement:
UL-580-94 w/Rev thru 1998/UL 1897-98: Test Report 07-0293T-06 A — C dated 1-
16-06 by Force Engineering and Testing, Inc. located in Humble, TX 77338. The
UL 580-94 test standard is equivalent to the UL 580-06 test standard. The UL
1897-98 test standard is equivalent to the UL 1897-12 test standard.
UL 790 Class A documentation under Section 1505.1, located in Northbrook, IL
60062.
Maximum Uplift Pressure: -146 psf @ V-0" o.c. See Detail "B"
-74.75 psf @ 2'-0" o.c. See Detail "B"
Application: Install 5V-Crimp per the manufacturers approved
detail. Use #10-15 fasteners of sufficient length to
penetrate 5/16" through the sheathing.
8M of Flodde
Is nr9b3j, 0.0A
°oyc°CaCJ E +°oa, 825718
n ��vy V• t` .fig
°
w t No.4492,�
219 '• STATE 0 ;
'ataea+o+°P
SEP 114 202
SY C M PASM
DTTAIL$
—2d' OOVERACIE-----=+
PANEL OVERLAP FASTENER WWASHER
SUBMAM PANELUNDERLAP
FAMENINO PATTERN AT & RIDGE OF PAWPA�ERN ATFIELD, SAVE & RIDGE OF PAW
Rffiteo9FlOfld®
QO.A.
oe CCO BAAAAA 026M
V E J
No.44323
STATE OF NA-RigAggsesA�