Loading...
HomeMy WebLinkAboutEVALUATION REPORTFile Cop,;. REVIEWED OR CODE COMPLIANCE SC BNNNED St. Lucie County NEORECta. ST. ILUCIE C�if���rQ'p� �y 4Y 1n,V\, �7 Certificaten Streeit, Unit#13 353 Christian Street, Unit i113 , Oxford, CT06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY Boral Roofing Evaluation Report M35710.12.30-R11 7575 Irvine Center Drive, Suite 100 FL14317-RSO Irvine, CA. 92618 Date of Issuance: 12/21/2010 (602) 269-2288 Revision 11:10/12/2018 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product underthe Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 61h Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Boral Roof Underlayments LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMO1etc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8 Prepared by: T' Robert J.M. Nieminen P.E. z ;'fp�n, •"^' The facsimile seal appearing was authorized by Robert ,'::4i,,,,,;,„�•, Florida Registration No. 59166, Florida DC4ANE7983 Nieminen, P.E. on 10/I2/2019. This does not serve as an ' electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEW ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEW ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ONEMoletc. ROOFING COMPONENT EVALUATION: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Boral Roof Underlayments, as marketed by Boral Roofing, have demonstrated ' compliance with the following sections of the 6'1" Ed t on'"(2017) Florida Building Code through'testing 16 accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. STANDARDS:2. Section _—Property—, _1504.3.1� Standard Year Wind Uplift UL 1897 2012 1507.1.1, T1507.1.1, Physical Properties ASTM D1970 2015 1507.2.9.2 1507.3.3 Physical Properties FRSA/TRI April 2012 (04-12) 2012 3. REFERENCES: Enti Examination Reference _ _ ERD (TST6049) Physical Properties M36790.07.11T _:Date_ 09/30/2011 ERD (TST 6049) Physical Properties B40380.08.12 08/28/2012 ERD (TST 6049) Tensile. Adhesion/LTA C41420.09.12-2 09/11/2012 ERD (TST 6049) Adhesion B41940.09.12 09/13/2012 ERD (TST 6049) Tensile Adhesion / LTA B47390.07.14-1 07/31/2014 ERD (TST 6049) Tensile Adhesion / LTA B47390.09.14 09/04/2014 OC (PDM1838) Physical Properties Equivalency statement 11/02/2017 PRI (TST5878) ASTM D1970 NEI-031-02-02:REV 10/27/2010 PRI (TST5878) ASTM D1970 NEI-029-02-01:REV 12/03/2010 PRI (TST 5878) Tensile Adhesion/LTA NEI-046-02-01REV 12/17/2010 PRI (TST 5878) FRSA/TRI April 2012 NEI-076-02-01 02/14/2011 PRI (TST5878) ASTM D1970 NEI-034-02-02 01/29/2013 PRI (TST5878) Wind Uplift BORR-001-02-01 03/17/2015 PRI (TST 5878) Wind Uplift BORR-005-02-01 06/24/2015 PRI (TST 5878) Tensile Adhesion / LTA DAPF-002-02-01 03/08/2018 PRI (TST 5878) ASTM D1970 (adhesion) OCF-443-02-01 10/11/2018 UL, U.C. (QUA 9625) Quality Assurance Service Confirmation Exp.08/21/2020 4. PRODUCT DESCRIPTION: 4.1 BoralO TileSeal 50"r is a nominal 50-mil thick, polyester -surfaced, self -adhering SBS modified bitumen roof underlayment; meets ASTM D1970. 4.2 Boral® TileSeal17 is a nominal 60-mil thick, polyester -surfaced, self -adhering SBS modified bitumen roof underlayment; meets ASTM D1970 and FRSA/TRI 04-12. 4.3 Boral® MetalSeal"r is a nominal 60-mil thick, polyester -surfaced, self -adhering SBS modified bitumen roof underlayment; meets ASTM D1970 and FRSA/TRI 04-12. 4.4 GatorSeal® is a nominal 55-mil thick, granular -surfaced, fiberglass reinforced, self -adhering SBS modified bitumen roof underlayment; meets ASTM D1970. 4.5 Citadel® Plus is a nominal 48-mil thick, fabric -surfaced, fiberglass reinforced, self -adhering SBS modified bitumen roofing underlayment for use as a base -layer in multi -ply underlayment systems; meets ASTM D1970. NEMO ETC, LLC Evaluation Report M35710.12.10-R11 Certificate of Authorization #32455 6t" EDITION (2017) FBC NON-HVHZ EVALUATION FL14317-RID Botal Roof Underlayments; (60Z) 269-2288 Revision 11: 10/12/2018 Page 2 of 8 ONEMOIetc. 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in anyway, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. • - 5.3 Fite Classificatio0s not part of this Laboratory Report; refer to current Approved Roofing Materials Dincctory for fire ratings of this product. 5.4 Boral Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval. documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: Table 1 pertains to use of each listed underlayment by -itself beneath the stated roof covers. Refer to the installation instructions for multi -ply underlayment options. TABLE 1: ROOF COVER OPTIONS Underlayment Asphalt` Nall•OnTile Adhesive -set M Metal WoodShakes Slate' Shingles Tile &Shingles, Boral Tile5eal 50w Yes No No Yes Yes Yes Boral TileSealw Yes Yes Yes Yes Yes Yes (See 5.5.1) Boral MetalSeal"r Yes Yes Yes Yes Yes Yes (See 5.5.1) GatorSeal Yes No No No Yes Yes 5.5.1 "Adhesive -set Tile" is limited to use of following Approved tile adhesives / underlayment combinations. TABLE IA: ALLOWABLE TILE ADHESIVE UNDERLAYMENT COMBINATIONS' Adhesive Florida Product • Underlayments Approval DAP Foam Touch'n Seal StormBond Roof Tile Adhesive FU4506 Boral TileSealw or Boral MetalSeal"r DAP Foam Touch'n Seal StormBond 2 Two -Component FL21374 floral TileSealwor Boral MetalSeal "T Polyurethane Roof Tile Adhesive Dow TILE BOND'" Roof Tile Adhesive FL22525 Boral TileSealw or Boral MetalSealw ICP Adhesives Polyset® AH-160 FL6332 Boral TileSealw or Boral MetalSeal"r ICP Adhesives Polyset® RTA-1 FL6276 Boral TileSeal" or Boral MetalSeal"r 'Refer to rile Manufacturers or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. NEMO ETC, LLC Evaluation Report M35710.12.10-R31 Certificate of Authonzation#32455 6TM EDITION (2017) FBC NON-HVHZ EVALUATION FL14317-R30 Boral Roof Underlayments; (602) 269-2288 Revision 11: 10/12/2018 Page 3 of 8 ONEMOletc. 5.6 Allowable Substrates: 5.6.1 Direct -Bond to Deck: Citadel Plus, Boral TileSeal 5011T, Boral TileSealHT, Boral MetalSeal"r or GatorSeal: ➢ Plywood (unprimed or primed with ASTM D41 primer). Boral TileSealw or Boral MetalSealw: ➢ OSB (unprimed or primed with ASTM D41 primer). Note: Refer to Section 5.6.4 for uplift limitations associated with direct -deck underlayment installations where the overlying roof cover is adhesive -set tile roofing 5.6.2 Bond to Base Laver Underlayment: Citadel Plus, Boral TileSeal 50'rr, Boral TileSealHT, Boral MetalSeal"T or GatorSeal: ➢ ASTM D226, Type 11 felt; Citadel Plus. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under adhesive -set tile systems, base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04-12), Appendix A, Table 1, or as listed in Section 5.6.4 herein, or as tested in accordance with FBC 1504.3.1. 5.6.3 Bond to Other Substrate Types: _.. Citadel Plus, Boral TileSeal 50w, Boral TileSealHT, Boral MetalSealw or GatorSeal: ➢ ASTM D41 primed metal (e.g., flashing metal, valley metal, etc.). Boral TileSealHT: ➢ Huber Zip Deck (unprimed or primed with ASTM D41 primer); Dens Deck Prime. Note: For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturers Product Approval. 5.6.4 Wind Resistance for Underlayment Systems in Adhesive -set Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath adhesive -set tile systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in adhesive -set tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12), Appendix A, Table 3A or FBC 1609 for determination of design wind loads #1 Maximum Design Pressure=-120.0 post: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) ASTM D41 to the plywood deck Base Ply: Citadel Plus, self -adhered Cap Sheet: Boral TileSealHT or Boral MetalSealw, self -adhered, and back -nailed within the selvedge -edge side laps using 12 ga. x 1%" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c. #2 Maximum Design Pressure=-142.5 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Ply: None Cap Sheet: Boral TileSealHT or Boral MetalSealw, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1'/e" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c. NEMO ETC, LLC Evaluation Report M35710.12.10-R31 Certificate of Authorization #32455 0 EDITION (2017) FBC NON-HVH2 EVALUATION FL14317-R10 Boral Roof Underlayments; (602) 269.2288 Revision 12: 10/12/2018 Page 4 of 8 ONEMoletc. #3 Maximum Design Pressure=-202.5 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: Tropical Roofing Products #410 Quick Dry Primer or other ASTM D41 primer to the plywood deck Base Ply: None Cap Sheet: Boral TileSeal'or Boral MetalSeal"r, self -adhered, and back -nailed within the selvedge -edge side laps using 12 ga. x 1Y<" ring shank nails through'32 ga., 1-5/8" diametertin caps spaced 12-inch o.c. #4 Maximum Design Pressure = -210.0 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: KARNAK #89 Sta-Tak Primer to the plywood deck Base Ply: None Cap Sheet: Boral TileSeal"TorBoral MetalSeal"T,self-adhered, and back -nailed within the selvedge -edge side laps using 12 ga, x 3Y<" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c. #5 Maximum Design Pressure=-120.0 psf: Deck: Min. 2,500 psi structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: ASTM D41 to the concrete deck Base Ply: (Optional) Citadel Plus, self -adhered Cap Sheet: Boral TileSeal"T or Boral MetalSeal"T, self -adhered 5.6.4.1 Note: For adhesive -set tile systems, if there is a base ply or mid -ply of Citadel Plus in the system, the project design pressure requirements may not exceed -120 psf. 5.7 Exposure Limitations: GatorSeal shall not be left exposed for longerthan 30-days after installation, priorto placement of final roof cover. Boral TileSeal 50"T, Boral TileSeal"r or Boral MetalSeal"T shall not be left exposed for longer than 180-days after installation, prior to placement of final roof cover. Citadel Pius, for use as a base -layer in a multi -ply underlayment system, shall not be left exposed for longer than 180-days after installation, priorto placement of subsequent underlayment layer. 5.8 Tile Slippage Limitations rFRSA/TRI April 2012 (04-12)1: When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. 6.1 Boral Roof Underlayments shall be installed in accordance with Boral Roofing published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.3 Install self -adhering underlayment when ambient and surface temperatures are minimum 40'17 and rising. NEMO ETC, LLC Evaluation Report M35710.12.10-R31 certificate ojAuthorization #32955 6- EDITION (2027) FBC NON-HVH2 EVALUATION FL14317-R30 floral Roof Underlayments; (602) 269-2288 Revision 11: 10/12/2018 Page 5 of 8 ONEMOIetc. 6.4 I Citadel Plus: 6.4.1 Citadel Plus is limited to use as a base or mid -layer in multi -ply underlayment systems beneath Boral TileSeal Boral TileSealK or GatorSeal. 6.4.2 Slope limitations are those associated with the top -layer underlayment. 6.4.3 Direct to Deck: Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge; extending over by Y.-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a weighted roller. Fasten the top edge of the sheet to the deck with corrosion resistant roofing nails, nails & tin -tags or 1-inch diameter plastic or steel cap nails spaced maximum 12-inch o.c. Overlap successive courses the entire width of the black -selvedge area, minimum 2 inches (horizontal lap) and minimum 6" end (vertical) laps. Install final underlayment layer atop Citadel Plus per 'direct -to -deck' instructions for Boral TileSeal 50", Boral TileSeal"T, Boral MetalSeaF or GatorSeal. 6.4.4 To Base Sheet: Install base sheet of ASTM D226, Type II felt in accordance with Code requirements or install base ply of Citadel Plus in accordance with Boral Roofing published installation instructions and Section 6.4.3 and when used as part of a multi -ply system. Install optional Citadel Plus as a mid -ply in accordance with Boral Roofing published installation instructions and Section 6.4.3. Install final underlayment layer atop Citadel Plus per 'direct -to -deck' instructions for Boral TileSeal 50"1, Boral TileSeal"r or GatorSeal. Note: For adhesive -set tile systems, if there is a base ply or mid -ply of Citadel Plus in the system, the project design pressure requirements may not exceed -120 psf. 6.5 Boral TileSeal SORT: 6.5.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.5.2 Do not use Boral TileSeal 50HT on roof pitches less than 2:12. 6.5.3 Non -Tile Applications, Direct to Deck: Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge, extending over by %-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a weighted roller. Fasten the blackselvedge edgeto the Beckwith corrosion resistant roofing nails, nails &tin -tags or 1-inch diameter plastic or steel cap nails spaced maximum 24-inch o.c. for slopes below 7:12 and maximum 12-inch o.c. for slopes 7:12 and greater. Overlap'successive courses the entire width of the black -selvedge area, minimum 3-inch. Seal under end (vertical) laps using approved mastic, or use Joined and Folded Seam or Inverted Sheet Seam method detailed in Boral Roofing published installation instructions. NEMO ETC, LLC Evaluation Report M35710.12.10-Rll Certificate of Authorization #32455 6TM EDITION (2017) FBC NON-HVHZ EVALUATION FL14317-R1O Boral Roof Underlayments; (602) 269-2288 Revision 11: 10/12/2018 Page 6 of 8 C n: c, 0 ONEMOletc. 6.5.4 Non -Tile Applications, to Base Sheet: Install ASTM D226, Type 11 felt in accordance with Cade requirements or install Citadel Plus in accordance with Boral Roofing published installation instructions and Section 6.4. Install Boral TileSeal 50HT in accordance over ASTM D226, Type II felt or Citadel Plus with Boral Roofing published -installation instructions and Section 6.5.3, except end (vertical) laps, described below. Apply SBS Mastic under all end (vertical) laps or any other laps where the self -adhering bituminous underside is in contact with the fabric top surface, rolling the interface into place with a weighted roller. 6.6 GatorSeal: 6.6.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.6.2 Do not use GatorSeal on roof pitches less than 2:12. 6.6.3 Non -Tile applications, Direct to Deck: Cut the membrane into manageable lengths, typically 30 to 12 ft. Align the membrane parallel to the roof edge, extending over by %-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a weighted roller. Fasten the black selvedge edge to the deckwith corrosion resistant roofing nails, nails & tin -tags or 1-inch diameter plastic or steel cap nails spaced 24-inch o.c. for slopes below 7:12 and 12-inch o.c. for slopes 7:12 and greater. Overlap successive courses the entire width of the black -selvedge area, minimum 3-inch. Seal end (vertical) laps using SBS Mastic under all side (vertical) laps or any other laps where the self -adhering bituminous underside is in contact with the granular or mineral top surface, rolling the interface into place with a weighted roller, or using the Inverted Sheet Seam detailed in Boral Roofing published installation instructions. 6.6.4 Non -Tile Applications, to Base Sheet: Install ASTM D226, Type 11 felt in accordance with Code requirements or install Citadel Plus in accordance with Boral Roofing published installation instructions and Section 6.4. Install GatorSeal over ASTM D226, Type II felt or Citadel Plus in accordance with Boral Roofing published installation instructions and Section 6.6.3 except end (vertical) laps, described below. Apply SBS Mastic under all side (vertical) laps or any other laps where the self -adhering bituminous underside is in contact with the granular top surface, rolling the interface into place with a weighted roller. 6.7 Boral TileSeal"T or Boral MetalSeal"T: 6.7.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.7.2 Do not use Boral TileSealw or Boral MetalSeal"T on roof pitches less than 2:12. 6.7.3 Non -Tile Applications. Direct to Deck: For OSB substrate, prime with ASTM D41 primer and allow to dry prior to installation. Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge, extending over by %-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a weighted roller. Fasten the black selvedge edge to the deck with roofing nails, nails & tin -tags or 1-inch diameter plastic or steel cap nails spaced maximum 12-inch D.C. Overlap successive courses the entire width of the black -selvedge area, minimum 3-inch. Seal under all end (vertical) laps using approved mastic or use Inverted Sheet Seam method detailed in Boral Roofing published installation instructions. NEW ETC, LLC Evaluation Report M35710.12.10-R31 Certificate ofAuthonzation #32455 0 EDITION (2017) FBC NON-HVHZ EVALUATION FL14317-RID Boral Roof Underlayments; (602) 269-2Z88 Revision 11: 10/12/2018 Page 7 of 8 ONEMOletc. 6.7.4 Non -Tile Applications, to Base Sheet: Install ASTM D226, Type II felt in accordance with Code requirements or install Citadel Plus in accordance with Boral Roofing published installation instructions and Section 6.4. Install Boral TileSealw or Boral MetalSeal"T over ASTM D226, Type II felt or Citadel Plus in accordance with Boral Roofing published installation instructions and Section 6.7.3, except end (vertical) laps, described below. Apply56S Mastic under all end (vertical) laps onany other laps where the self -adhering bituminous underside is in contact with the fabric top surface, rolling the interface into place with a weighted roller. 6.7.5 Tile Applications: Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. For mechanically fastened tile roofing over 2-ply system, consisting of Base Sheet and self -adhering top sheet(s), Base Sheet fastening shall be not less than FRSA/TRI April 2012 (04-12), Table 1. For adhesive -set tile applications, refer to Section 5.6.4 herein. Note: For adhesive -set tile systems, if there is a base ply or mid -ply of Citadel Plus in the system, the project design pressure requirements may not exceed -120 psf. Refer to Section 5.8 for tile staging limitations. Battens must be used for all tile installations atop Boral TileSeaF or Boral MetalSeal"T with roof pitches of 2%to less than 3:12. Boral Roofing's Elevated Batten System or counter battens are required. As required by the Building Official or Authority Having Jurisdiction in order to this product. 8. MANUFACTURING PLANTS: Brentwood, UL, LLC. — QUA9625; (631) 546-2458; Kanchi.Agrawala-Dokania@ul.com - END OF EVALUATION REPORT - NEMO ETC, LLC Evaluation Report M35710.12.30-R31 certificate of Authorization #32455 6n' EDITION (2017) FBC NON-HVHZ EVALUATION FL14317-R10 Boral Roof Underlayments; (602) 269-2288 Revision 11: 10/12/2018 Page 8 of 8 EXTERIOR RESEARCH & DESIGN, U.C. .. Certificate OfAuthori2Dtion 49503 SGANNty 353 CHRISTIAN STREET, UNIT #13 q0T�RINIfY �'E D BY OXFORD, CT 0647E " St. Lucien County PHONE: (203) 262-9245 FAX: (203) 262-9243 EVALUATION REPORT East Coast Metals, Inc. Evaluation Report E10240.08.08-R4 2301 West Lane FL5374-114 Hialeah, FL 33010 Date of Issuance: 09/03/2008 Revision 4: 03/17/2015 SCOPE: This Evaluation Report is Issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5`s Edition (2014) Florida Building Code sections noted herein. DESCRIPTION: East Coast Metals Channel Metals LABEONG: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the productchanges or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by. the manufacturer or its distributors and shall be available for inspection at the job site at the requestof the Building Official. This Evaluation Report consists of pages 1 through 7. Prepared by: •9-"�s.<+.= —• +i.+E. Ilia hvim4e teals Robert l.M.Nieminen,P.E. ''•o,.: rS.°�t' ppearm8waaauthaued Robe,INkmmen, y r=!1:. ��r Tttls doeaoot tetreasa len,anka�Ma�Bned Florida Registration No. 59166, Florida OCA ANE1983 tP.Eon0117/2015.dm;mn4Fned.ualetl lurdmpkx beve been mnsmittetlmtAe `i'=Pa""'1^'�t produtt Approval Admindvatorandtmhe nan�eA client CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial Interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. S. This is a building code evaluation. Neither Trinity ERD nor Robert Nleminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. �-TRINITYJERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Roofing Accessories that are an Integral Part of the Roofing System Compliance Statement: East Coast Metals Channel Metals, as produced by East Coast Metals, have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard year 1507.3.7 Installation, non-HVHZ FRSA/rRI April 2012(04-12) 2012 1518.8.1 Installation, HVHZ RAS 118, 119 & 120 1995 1523.65.2.2 Static Uplift Resistance TAS 101 1995 1711.2.1 Static Uplift Resistance SBCCI SSTD 11 1997 3. REFERENCES: Enti Examination Reference Date ERD(TST6049) Static Uplift Resistance E42730.08.13 08/23/2023 ERD(TSf6049) Static Uplift Resistance ECM-SC6795.12.14-1 02/27/2015 ERD(T5T6049) Static Uplift Resistance ECM-SC6795.12.14.2 02/27/2015 Florida TEC(TST7393) TAS 101 51D-62811 10/27/2010 PRI (TST5878) TAS 101 ECM-001-02-01 09/21/2001 PRI (TST5878) TAS 101 ECM-003-02-01 06/13/2008 PRI (TST5878) TAS 101 ECM-004.02-DS O6/1312008 PRI (TST5878) TAS 101 ECM-005-02.01 06/13/2008 PRI (TST5878) TAS 101 ECM-006-02-01 06/13/2008 PRI (TST5878) TAS 101 ECM-007-02-01 06/13/2009 PRI (TST5878) TAS 101 ECM-008-02-01 06/2312008 Florida Building Code Attachment Requirements FRSA(TRI April 2012(04-12) 04/2012 Florida Building Code - HVHZ Attachment Requirements RAS 118, 119 and 120 1995 East Coast Metals Metal Quality Mill Certifications Various Architectural Testing(QUA1844) Quality Control Participation Letter Exp. 12/31/2018 4. PRODUCT DESCRIPTION: 4.1 Hip & Ridge Channel Metal: Pre -formed metal channel designed for use as a hip and ridge base to which roof tiles are bonded in FBC Approved roof tile adhesive. Hip & Ridge Channel Metal Is available in 119-3/8-Inch (+ 3/8-inch) length by 2.5, 3, 3.5, 4, 5, 6 or 7-inch Lt 3/8-inch) heights with 1.5-inch (±1/16-inch) deck -flanges. Exterior Research and Design, LLG Evaluation Report E10240.09.08-R4 Certificate ofAuthorinufm A9S03 FL5374-R4 Revision 4:03/17/2015 Page 2 of 7 N4 . j INITY f ERD 4.2 Trim Lock Channel Metal: Pre -formed metal channel designed for use as a hip and ridge base to which roof tiles are bonded In FBC Approved roof tile adhesive. Trim Lock Channel Metal is characterized by its profiled and perforated upper horizontal flange designed to receive and allow for interlock with the overlying tile adhesive. Trim Lock Channel Metal is available in 119-3/8-inch 3/8") length by 3, 3.5, 4, 5 or 6-inch (± 3/8-inch) heights with 1.5-inch (±1/16-inch) deck -flanges. 4.2 Trim Lock Plus Channel Metal: Pre -formed metal channel designed for use as a hip and ridge base to which roof tiles are bonded. in FBC Approved roof tile adhesive. Trim Lock Plus Channel Metal is characterized by its profiled and perforated upper horizontal flange designed to receive and allow for Interlock with the overlying tile adhesive and Its perforated deck flanges, designed for installation atop the roof underlayment via placement In FBC Approved roof tile adhesive, which flows -through and Interlocks with the underlying adhesive. Trim Lock Plus Channel Metal is available in 119-3/8-inch L 3/8") length by 3, 3.5, 4, 5 or 6-inch (±3/8-inch) heights with 1.5-Inch (±1/16-Inch) deck -flanges. 4.4 East Coast Metals Channel Metals are fabricated of the following metals: > Galvanized Steel: Min. 0.019±0.002-inch, ASTM A653(G-90), min. 33 K51. > Galvalume Steel: Min. 0.019±0.002-Inch, ASTM A792, AZ55, min. 35 KSI. > Aluminum: Min. 0.032 ±0.002-inch, ASTM B209, 3003-1-114, min. 21 KSI. > Stainless Steel: Min. 0.019±0.002-Inch, ASTM A240/A480, T304, min. 35 KSI. S. LIMITATIoNs: 5.1 This is a building code evaluation. Neither Trinity)ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. Exterior Research and Design, LLC. Evaluation Report E30240.08.08-R4 CertifiWit ofAWhodratfm 99503 FL5374-114 Revision 4:03/17/2015 Page 3 of 7 `.I I KINITY ERD 5.2 FOR HVHZJURISDICfIONS: 5.2.1 For Hip & Ridge Channel Metal or Trim Lock Channel Metal, refer to FBC RAS 118, Drawing 13, Detail 3; RAS 119, Drawing 12, Detail 3; or RAS 120, Drawing 15, Detail 3. For Trim Lock Plus Channel Metal, refer to the installation instructions herein. 5.2.2 For HVHZ jurisdictions, Installations of Hip & Ridge Channel Metal and Trim Lock are prescriptive by RAS 118, 119 and.. 120, and the data in Tables SA and 18 is supplemental to theseprescrtptive allowances. Installations of Trim Lock Plus are limited to projects having a required moment resistance (M,) or uplift resistance (Frj, as determined in accordance with RAS 127, not greater than the following values. Refer to the tile adhesive manufacturer's published installation instructions for adhesive paddy placement details. Y "INDEPENDENT' paddy placement means each individual tile Is bonded to the Channel Metal in Its own, single foam paddy; the head laps are not bonded. This method is limited to 2-part tile adhesives. Allowable performance data below for "INDEPENDENT" paddy placement already has a 2 to 1 margin of safety applied to ultimate performance. D "INTERDEPENDENT" paddy placement means each Individual the Is bonded to the Channel Metal in a foam paddy, and a second foam paddy bonds the the head lap, or two tiles are bonded to the Channel Metal using a single foam paddy. Allowable performance data below for "INTERDEPENDENT' paddy placement already has a 4 to 1 margin of safety applied to ultimate performance. 3y J { YI xi y Yt 1AeLF1AfP RMwcEiMrtanoxs''#hfkiZ,fNMF � ENOExtPAbpyP it �p,� �It { g } '' Y, �f 1tXPi�`i"Afij .�-.�.m ''hard at1fS�i tL�`"..�..'fji#+:r�±iilrflAtkRGiN OF'unEROIA�HiIp/d��... "#,.t}.rid. t�3:'.:-.ss{�,'.i.�,'����(�ii,'„�'�'l a•'l.e Hip/Ridge Metal Tile Adhesive Allowable Performance Design Metal Type Type Placement Moment Based Uplift Based M,(R-Ibf) F'(Ibf) Hip & Ridge galvanized dayor 3M" 2-Component Foam Independent 127 169 Channel Metal concrete Roof Tile Adhesive AH-160 Trim Lock galvanized, Galvalume•, - clay or 3M"' 2-Component Foam Independent 271 159 aluminum or stainless steel concrete Roof Tile Adhesive AH-160 Trim Lock Plus galvanized, Galvalumee, clay or 3M"' 2-Component Foam Independent 177 165 aluminum or stainless steel concrete Roof Tile Adhesive AH-160 s }q 1111t i,(yff y,s s s }}h` fiABU B PERF9RT.t41K, Il rf + �IM1iRdT10NSr'FI�!�Ij°ItiTE D pFNbEM PlA EHT kill$-} " '3+ ' `" r '�{+�f i.. r -�-�,., ` tijall q 1 ,„�.t q 2aaiF*'1§ t�Jt)afty RP�ApO ,�i S ra j° !�''I€� � s rif- m,1 �a42 3xiz'}.i'.. i f4m1 4AGIXOFSAiort AYYs(rEos -t att+liE, s.Se Hip/RldgeMetal Tile Adhesive Allowable Performance Design Metal Type Type Placement Moment Based Uplift Based M,(ft-lbf) F'(Ibf) Trim Lock or Trim galvanized, Galvalume•, clay or 3M"'1-Component Foam Lock Plus - aluminum or stainless steel concrete Roof Tile Adhesive AN-160 Interdependent 95 88 Trim Lock galvanized, Galvalume°, clay or 31A ' Roof Tile Adhesive Interdependent 99 94 stainless steel concrete RTA-1 Trim Lock aluminum clay or 3M"' Foam Roof Tile Interdependent 90 84 concrete Adhesive RTA-1 Trim lack Plus galvanized, Galvalume•, galvanized, dayor 31v-Foam RoofTlle Interdependent 90 84 orstainlesssteel concrete Adhesive RTA-1 Trim Lock galvanized, Galvalume• or clay or TILE BOND"' Roof Tile Interdependent 123 117 stainless steel concrete Adhesive Trim Lock aluminum clay or TILE BOND -Roof Tile Interdependent 79 73 concrete Adhesive Trim Lock Pius galvanized, Gahvalume•, dayor TILE BOND" Roof Tile Interdependent 79 73 aluminum. or stainless steel concrete Adhesive Tdm Lork galvanized, Galvalume• or dayor Touch'n Seal StormBond Interdependent 146 139 stainless steel concrete Roof Tile Adhesive Trim lock Aluminum clay or Touch'n Seal StormBond Interdependent 58 54 concrete Roof Tile Adhesive Trim lock Plus galvanized, Galvalumee, day or Touch'n Seal StormBond Interdependent 58 54 aluminum or stainless steel concrete Roof Tile Adhesive Exterior Research and Design, Lu: Evaluation Report E30240.08.08-R4 Certiifkate ofAUMcrketkm 89503 FL5374-R4 Revision 4:03/17/2015 Page 4 of 7 �,J � RINITY ERD 5.3 FOR NON-HVH2 JURISDICTIONS: 5.3.1 For Hip & Ridge Channel Metal or Trim Lock Channel Metal, refer to FRSA/TRI April 2012 (04-12). For Trim Lock Plus Channel Metal, referto the installation instructions herein 5.3.2 For non-HVH2, installations are limited to projects having hip and ridge design pressure requirements, determined in accordance with Table 1A of FRSA/TRI April 2012 (04-12), not greater than the following values. Refer to the tile - adhesive manufacturer's published installation Instructions for adhesive paddy placement details. " ➢ "INDEPENDENT' paddy placement means each individual tile is bonded to the Channel Metal in its own, single foam paddy; tile head laps are not bonded. This method Is limited to 2-part the adhesives. This method is limited to 2-part tile adhesives. Allowable performance data below for "INDEPENDENT' paddy placement already has a 2 to 1 margin of safety applied to ultimate performance. D "INTERDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in a foam paddy, and a second foam paddy bonds the the head lap, or two tiles are bonded to the Channel Metal using a single foam paddy. Allowable performance data below for "INTERDEPENDENT" paddy placement already has a 4 to 1 margin of safety applied to ultimate performance. tsitsbnri,,J.,AeAP OnNLD{ns�'or,HP_xrAoo�p- tiAaitYa' M1md7at& 1T¢r;f fatt es;"a Hip/Ridge Metal Tile Adhesive - Allowable Uplift (psf) Design Metal Type Type Placement Hip & Ridge Channel Metal galvanized clay or 3M" 2-Component Foam Roof Independent 169 concrete Tile Adhesive AH-160 Trim Lock galvanized, Galvalume°, aluminum or clay or 3M'" 2-Component Foam Roof Independent 173 stainlesssteel concrete Tile Adhesive AH-160 Trim Lock Plus galvanized, Galvalume", aluminum or clay or 3M'" 2-Component Foam Roof Independent 178 stainless steel concrete Tile Adhesive AH-160 )h F 2s " jyjzft 1z § Ti1dLE28 PERFORMANCE Idefir Tloils'-#Nof3•H n i�'�E{ft1}(';ylFn��NS y%If rr,.. �y{,tiZpHt`nya(�r;x TMReF4IT H�Ca Hip/Ridge Metal Tile Adhesive Allowable Uplift (Psf) Design Metal Type Type Placement Trim Lock or Trim galvanized, Galvalume•, aluminum or clayor 3M"'2-Component Foam Roof Lock Pius stainless steel concrete Tile Adhesive AH-160 Interdependent 98 Trun Lock galvanized, Galvalume° or stainless clayor 3M" Foam Roof Tile Adhesive Interdependent 330 steel concrete RTA-1 Trim Lock aluminum clayor 3M"' Foam Roof Tile Adhesive Interdependent 93 concrete RTA-1 Trim Lock Plus galvanized, Galvalume•, aluminum or clay or 3M"' Foam Roof Tile Adhesive Interdependent 93 stainless steel concrete RTA-1 Trim Lock galvanized, Galvalume• or stainless clayor TILE BOND" Roof Tile Adhesive Interdependent 152 steel - concrete Trim Lock aluminum clayor TILE BOND"' Roof Tile Adhesive Interdependent 82 concrete Trim Lock Plus galvanized, Galvalume•, aluminum or clay or TILE. BOND" Roof Tile Adhesive Interdependent 82 stainlesssteel concrete Trim Lock galvanized, Galvalume• or stainless clayor Touch'n Seal Storm Bond Roof Interdependent 148 steel concrete Tile Adhesive Trim lock Aluminum day or ToucIn Seal StannSond Roof Interdependent 61 concrete Tile Adhesive Trim Lack Plus Galvanized, Galvalume•, aluminum or clay or Touch'n Seal Stormeond Roof Interdependent 61 stainlesssteel concrete Tile Adhesive Exterior Research and Design, LLC Evaluation Report E30240.08.08-R4 Certylrore ofAudwrizadon a9S03 FL5374•R4 Revision 4:03/17/2015 Page 5 of 7 `J TRINITY E� 6. INSTALLATION: 6.1 The roof deck shall be minimum 15/32-Inch plywood (non-HVHZ) or minimum 19/32-inch plywood (HVHZ) attached in accordance with FBC Chapter 23 to the satisfaction of the AHJ. 6.2 Hip & Ridge Channel Metal and Trim Lock Channel Metal shall be installed using min. 11 ga. x 3Y-inch long x 3/8-inch - head diameter galvanized annular ring shank nails spaced 6-inch o.c. along both deck -flanges. Fasteners shall be positioned Y-inch from the outside edge of each deck -flange, set In a bed plastic roof cement. For FBC HVHZ, refer to FBC RAS 118, Drawing 13, Detail 3; RAS 119, Drawing 12, Detail 3; or RAS 120, Drawing 15, Detail 3. 6.3 Trim Lock Plus Channel Metalshall be Installed atop the Approved roof underlayment in continuous 2-inch wide ribbons of tile adhesive centered beneath each 1.5-Inch wide deck flange. Place the Trim Lock Plus Channel Metal into the wet adhesive and allow it to set-up prior to installation of roof tiles. View of Polyset AH160 Placement for Trim Lock Plus Channel Metal Installation 6.3.1 It is critical that the bond between the Trim Lock Plus Channel Metal, the tile adhesive and the underlayment is not disturbed prior to or during placement of the ridge tiles. 6.3.2 Approved underlayments are the codified '30/90' system or other FBC Approved roof underlayments listing approved use of the subject tile adhesive. Exterior Research and Design, U.C. Evaluation Report E10240.08.08-R4 CerdprateolAud odunion 0003 FL53744t4 Revision 4:03/17/201S Page 6 of 7 �J TRINITY I ERD 6.4 Tile shall be installed atop the Channel Metal in accordance with the the adhesive manufacturer's Approved, published Installation Instructions, subject to the limitations outlined in Section 5 herein. The exposed edges shall be packed and pointed with Approved mortar or weather blocking adhesive in accordance with FRSA/TRI April 2012 (04-12) or RAS 118, RAS 119, RAS 120 requirements. Hip / Ridge Tile Tile Adhesive Trim Lock Plus Mortar or Weather Block Adhesive Tile Adhesive View of Trim Lock Plus Channel Metal Installation after Weather Blocked 6A.1 Channel Metal shall be free of dust, debris, oils or other bond -breaking substance prior to placement of adhesive. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. B. MANUFACTURING PLANTS: Contact the named CIA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. 9. QUALITY ASSURANCE ENTITY: Architectural Testing, Inc. — QUA1844�(717) 764-7700 END OF EVALUATION REPORT - Exterior Research and Design, U.C. Evaluation Report E10240.08.0&R4 Certf=re OfAurhodn0l.#9503 FL5374-R4 Revision 4:03/17/2015 Page 7 of 7