HomeMy WebLinkAboutEVALUATION REPORTFile Cop,;.
REVIEWED OR
CODE COMPLIANCE
SC BNNNED St. Lucie County
NEORECta.
ST. ILUCIE C�if���rQ'p�
�y 4Y 1n,V\, �7
Certificaten Streeit, Unit#13
353 Christian Street, Unit i113
,
Oxford, CT06478
(203)262-9245
ENGINEER EVALUATE
TEST CONSULT CERTIFY
Boral Roofing
Evaluation Report M35710.12.30-R11
7575 Irvine Center Drive, Suite 100
FL14317-RSO
Irvine, CA. 92618
Date of Issuance: 12/21/2010
(602) 269-2288
Revision 11:10/12/2018
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product underthe Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 61h Edition (2017) Florida Building Code sections noted
herein.
DESCRIPTION: Boral Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the
product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of
this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMO1etc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8
Prepared by:
T'
Robert J.M. Nieminen P.E.
z
;'fp�n, •"^' The facsimile seal appearing was authorized by Robert
,'::4i,,,,,;,„�•,
Florida Registration No. 59166, Florida DC4ANE7983
Nieminen, P.E. on 10/I2/2019. This does not serve as an
' electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEW ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEW ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
ONEMoletc.
ROOFING COMPONENT EVALUATION:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Boral Roof Underlayments,
as marketed by Boral Roofing,
have demonstrated
'
compliance with the following sections of the 6'1" Ed t on'"(2017) Florida Building Code through'testing 16
accordance with the following Standards. Compliance is subject to the Installation Requirements
and Limitations
/ Conditions of Use set forth herein.
STANDARDS:2.
Section _—Property—,
_1504.3.1�
Standard
Year
Wind Uplift
UL 1897
2012
1507.1.1, T1507.1.1, Physical Properties
ASTM D1970
2015
1507.2.9.2
1507.3.3 Physical Properties
FRSA/TRI April 2012 (04-12)
2012
3.
REFERENCES:
Enti Examination
Reference _ _
ERD (TST6049) Physical Properties
M36790.07.11T
_:Date_
09/30/2011
ERD (TST 6049) Physical Properties
B40380.08.12
08/28/2012
ERD (TST 6049) Tensile. Adhesion/LTA
C41420.09.12-2
09/11/2012
ERD (TST 6049) Adhesion
B41940.09.12
09/13/2012
ERD (TST 6049) Tensile Adhesion / LTA
B47390.07.14-1
07/31/2014
ERD (TST 6049) Tensile Adhesion / LTA
B47390.09.14
09/04/2014
OC (PDM1838) Physical Properties
Equivalency statement
11/02/2017
PRI (TST5878) ASTM D1970
NEI-031-02-02:REV
10/27/2010
PRI (TST5878) ASTM D1970
NEI-029-02-01:REV
12/03/2010
PRI (TST 5878) Tensile Adhesion/LTA
NEI-046-02-01REV
12/17/2010
PRI (TST 5878) FRSA/TRI April 2012
NEI-076-02-01
02/14/2011
PRI (TST5878) ASTM D1970
NEI-034-02-02
01/29/2013
PRI (TST5878) Wind Uplift
BORR-001-02-01
03/17/2015
PRI (TST 5878) Wind Uplift
BORR-005-02-01
06/24/2015
PRI (TST 5878) Tensile Adhesion / LTA
DAPF-002-02-01
03/08/2018
PRI (TST 5878) ASTM D1970 (adhesion)
OCF-443-02-01
10/11/2018
UL, U.C. (QUA 9625) Quality Assurance
Service Confirmation
Exp.08/21/2020
4.
PRODUCT DESCRIPTION:
4.1
BoralO TileSeal 50"r is a nominal 50-mil thick, polyester -surfaced, self -adhering SBS modified bitumen roof
underlayment; meets ASTM D1970.
4.2
Boral® TileSeal17 is a nominal 60-mil thick, polyester
-surfaced, self -adhering SBS
modified bitumen roof
underlayment; meets ASTM D1970 and FRSA/TRI 04-12.
4.3
Boral® MetalSeal"r is a nominal 60-mil thick, polyester -surfaced, self -adhering SBS
modified bitumen roof
underlayment; meets ASTM D1970 and FRSA/TRI 04-12.
4.4
GatorSeal® is a nominal 55-mil thick, granular -surfaced, fiberglass reinforced, self -adhering
SBS modified bitumen
roof underlayment; meets ASTM D1970.
4.5
Citadel® Plus is a nominal 48-mil thick, fabric -surfaced, fiberglass
reinforced, self -adhering
SBS modified bitumen
roofing underlayment for use as a base -layer in multi -ply
underlayment systems; meets ASTM D1970.
NEMO ETC, LLC Evaluation Report M35710.12.10-R11
Certificate of Authorization #32455 6t" EDITION (2017) FBC NON-HVHZ EVALUATION FL14317-RID
Botal Roof Underlayments; (60Z) 269-2288 Revision 11: 10/12/2018
Page 2 of 8
ONEMOIetc.
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in anyway, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
• - 5.3 Fite Classificatio0s not part of this Laboratory Report; refer to current Approved Roofing Materials Dincctory for
fire ratings of this product.
5.4 Boral Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval. documents. If not listed, a request may be made to the Authority Having Jurisdiction for
approval based on this evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable Roof Covers: Table 1 pertains to use of each listed underlayment by -itself beneath the stated roof
covers. Refer to the installation instructions for multi -ply underlayment options.
TABLE 1:
ROOF COVER OPTIONS
Underlayment
Asphalt`
Nall•OnTile
Adhesive -set
M
Metal
WoodShakes
Slate'
Shingles
Tile
&Shingles,
Boral Tile5eal 50w
Yes
No
No
Yes
Yes
Yes
Boral TileSealw
Yes
Yes
Yes
Yes
Yes
Yes
(See 5.5.1)
Boral MetalSeal"r
Yes
Yes
Yes
Yes
Yes
Yes
(See 5.5.1)
GatorSeal
Yes
No
No
No
Yes
Yes
5.5.1 "Adhesive -set Tile" is limited to use of following Approved tile adhesives / underlayment combinations.
TABLE IA: ALLOWABLE TILE ADHESIVE
UNDERLAYMENT COMBINATIONS'
Adhesive
Florida Product
•
Underlayments
Approval
DAP Foam Touch'n Seal StormBond Roof Tile Adhesive
FU4506
Boral TileSealw or Boral MetalSeal"r
DAP Foam Touch'n Seal StormBond 2 Two -Component
FL21374
floral TileSealwor Boral MetalSeal "T
Polyurethane Roof Tile Adhesive
Dow TILE BOND'" Roof Tile Adhesive
FL22525
Boral TileSealw or Boral MetalSealw
ICP Adhesives Polyset® AH-160
FL6332
Boral TileSealw or Boral MetalSeal"r
ICP Adhesives Polyset® RTA-1
FL6276
Boral TileSeal" or Boral MetalSeal"r
'Refer to rile Manufacturers or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
NEMO ETC, LLC Evaluation Report M35710.12.10-R31
Certificate of Authonzation#32455 6TM EDITION (2017) FBC NON-HVHZ EVALUATION FL14317-R30
Boral Roof Underlayments; (602) 269-2288 Revision 11: 10/12/2018
Page 3 of 8
ONEMOletc.
5.6 Allowable Substrates:
5.6.1 Direct -Bond to Deck:
Citadel Plus, Boral TileSeal 5011T, Boral TileSealHT, Boral MetalSeal"r or GatorSeal:
➢ Plywood (unprimed or primed with ASTM D41 primer).
Boral TileSealw or Boral MetalSealw:
➢ OSB (unprimed or primed with ASTM D41 primer).
Note: Refer to Section 5.6.4 for uplift limitations associated with direct -deck underlayment installations where the
overlying roof cover is adhesive -set tile roofing
5.6.2 Bond to Base Laver Underlayment:
Citadel Plus, Boral TileSeal 50'rr, Boral TileSealHT, Boral MetalSeal"T or GatorSeal:
➢ ASTM D226, Type 11 felt; Citadel Plus.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For installations under adhesive -set tile systems, base layer shall be attached per minimum
requirements of FRSA/TRI April 2012 (04-12), Appendix A, Table 1, or as listed in Section 5.6.4 herein, or as tested
in accordance with FBC 1504.3.1.
5.6.3 Bond to Other Substrate Types:
_.. Citadel Plus, Boral TileSeal 50w, Boral TileSealHT, Boral MetalSealw or GatorSeal:
➢ ASTM D41 primed metal (e.g., flashing metal, valley metal, etc.).
Boral TileSealHT:
➢ Huber Zip Deck (unprimed or primed with ASTM D41 primer); Dens Deck Prime.
Note: For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturers Product Approval.
5.6.4 Wind Resistance for Underlayment Systems in Adhesive -set Tile Applications: FRSA/TRI April 2012 (04-12) does
not address wind uplift resistance of all underlayment systems beneath adhesive -set tile systems, where the
underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems
that are not addressed in FRSA/TRI April 2012 (04-12) and are used in adhesive -set tile applications. Maximum
Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the
ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer
to FRSA/TRI April 2012 (04-12), Appendix A, Table 3A or FBC 1609 for determination of design wind loads
#1 Maximum Design Pressure=-120.0 post:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: (Optional) ASTM D41 to the plywood deck
Base Ply: Citadel Plus, self -adhered
Cap Sheet: Boral TileSealHT or Boral MetalSealw, self -adhered, and back -nailed within the selvedge -edge side laps
using 12 ga. x 1%" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c.
#2 Maximum Design Pressure=-142.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Ply: None
Cap Sheet: Boral TileSealHT or Boral MetalSealw, self -adhered and back -nailed within the selvedge -edge side laps
using 12 ga. x 1'/e" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c.
NEMO ETC, LLC Evaluation Report M35710.12.10-R31
Certificate of Authorization #32455 0 EDITION (2017) FBC NON-HVH2 EVALUATION FL14317-R10
Boral Roof Underlayments; (602) 269.2288 Revision 12: 10/12/2018
Page 4 of 8
ONEMoletc.
#3 Maximum Design Pressure=-202.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: Tropical Roofing Products #410 Quick Dry Primer or other ASTM D41 primer to the plywood deck
Base Ply: None
Cap Sheet: Boral TileSeal'or Boral MetalSeal"r, self -adhered, and back -nailed within the selvedge -edge side laps
using 12 ga. x 1Y<" ring shank nails through'32 ga., 1-5/8" diametertin caps spaced 12-inch o.c.
#4 Maximum Design Pressure = -210.0 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: KARNAK #89 Sta-Tak Primer to the plywood deck
Base Ply: None
Cap Sheet: Boral TileSeal"TorBoral MetalSeal"T,self-adhered, and back -nailed within the selvedge -edge side laps
using 12 ga, x 3Y<" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c.
#5 Maximum Design Pressure=-120.0 psf:
Deck: Min. 2,500 psi structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: ASTM D41 to the concrete deck
Base Ply: (Optional) Citadel Plus, self -adhered
Cap Sheet: Boral TileSeal"T or Boral MetalSeal"T, self -adhered
5.6.4.1 Note: For adhesive -set tile systems, if there is a base ply or mid -ply of Citadel Plus in the system, the project design
pressure requirements may not exceed -120 psf.
5.7 Exposure Limitations:
GatorSeal shall not be left exposed for longerthan 30-days after installation, priorto placement of final roof cover.
Boral TileSeal 50"T, Boral TileSeal"r or Boral MetalSeal"T shall not be left exposed for longer than 180-days after
installation, prior to placement of final roof cover.
Citadel Pius, for use as a base -layer in a multi -ply underlayment system, shall not be left exposed for longer than
180-days after installation, priorto placement of subsequent underlayment layer.
5.8 Tile Slippage Limitations rFRSA/TRI April 2012 (04-12)1:
When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as
follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
6.1 Boral Roof Underlayments shall be installed in accordance with Boral Roofing published installation instructions
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application, and prime the substrate (if applicable).
6.3 Install self -adhering underlayment when ambient and surface temperatures are minimum 40'17 and rising.
NEMO ETC, LLC Evaluation Report M35710.12.10-R31
certificate ojAuthorization #32955 6- EDITION (2027) FBC NON-HVH2 EVALUATION FL14317-R30
floral Roof Underlayments; (602) 269-2288 Revision 11: 10/12/2018
Page 5 of 8
ONEMOIetc.
6.4 I Citadel Plus:
6.4.1 Citadel Plus is limited to use as a base or mid -layer in multi -ply underlayment systems beneath Boral TileSeal
Boral TileSealK or GatorSeal.
6.4.2 Slope limitations are those associated with the top -layer underlayment.
6.4.3 Direct to Deck:
Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge;
extending over by Y.-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place
the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with
a weighted roller.
Fasten the top edge of the sheet to the deck with corrosion resistant roofing nails, nails & tin -tags or 1-inch
diameter plastic or steel cap nails spaced maximum 12-inch o.c. Overlap successive courses the entire width of the
black -selvedge area, minimum 2 inches (horizontal lap) and minimum 6" end (vertical) laps.
Install final underlayment layer atop Citadel Plus per 'direct -to -deck' instructions for Boral TileSeal 50", Boral
TileSeal"T, Boral MetalSeaF or GatorSeal.
6.4.4 To Base Sheet:
Install base sheet of ASTM D226, Type II felt in accordance with Code requirements or install base ply of Citadel
Plus in accordance with Boral Roofing published installation instructions and Section 6.4.3 and when used as part
of a multi -ply system.
Install optional Citadel Plus as a mid -ply in accordance with Boral Roofing published installation instructions and
Section 6.4.3.
Install final underlayment layer atop Citadel Plus per 'direct -to -deck' instructions for Boral TileSeal 50"1, Boral
TileSeal"r or GatorSeal.
Note: For adhesive -set tile systems, if there is a base ply or mid -ply of Citadel Plus in the system, the project design
pressure requirements may not exceed -120 psf.
6.5 Boral TileSeal SORT:
6.5.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for
the type of prepared roof covering to be installed.
6.5.2 Do not use Boral TileSeal 50HT on roof pitches less than 2:12.
6.5.3 Non -Tile Applications, Direct to Deck:
Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge,
extending over by %-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place
the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with
a weighted roller.
Fasten the blackselvedge edgeto the Beckwith corrosion resistant roofing nails, nails &tin -tags or 1-inch diameter
plastic or steel cap nails spaced maximum 24-inch o.c. for slopes below 7:12 and maximum 12-inch o.c. for slopes
7:12 and greater. Overlap'successive courses the entire width of the black -selvedge area, minimum 3-inch.
Seal under end (vertical) laps using approved mastic, or use Joined and Folded Seam or Inverted Sheet Seam
method detailed in Boral Roofing published installation instructions.
NEMO ETC, LLC Evaluation Report M35710.12.10-Rll
Certificate of Authorization #32455 6TM EDITION (2017) FBC NON-HVHZ EVALUATION FL14317-R1O
Boral Roof Underlayments; (602) 269-2288 Revision 11: 10/12/2018
Page 6 of 8
C
n:
c,
0
ONEMOletc.
6.5.4 Non -Tile Applications, to Base Sheet:
Install ASTM D226, Type 11 felt in accordance with Cade requirements or install Citadel Plus in accordance with
Boral Roofing published installation instructions and Section 6.4.
Install Boral TileSeal 50HT in accordance over ASTM D226, Type II felt or Citadel Plus with Boral Roofing published
-installation instructions and Section 6.5.3, except end (vertical) laps, described below.
Apply SBS Mastic under all end (vertical) laps or any other laps where the self -adhering bituminous underside is in
contact with the fabric top surface, rolling the interface into place with a weighted roller.
6.6 GatorSeal:
6.6.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for
the type of prepared roof covering to be installed.
6.6.2 Do not use GatorSeal on roof pitches less than 2:12.
6.6.3 Non -Tile applications, Direct to Deck:
Cut the membrane into manageable lengths, typically 30 to 12 ft. Align the membrane parallel to the roof edge,
extending over by %-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place
the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with
a weighted roller.
Fasten the black selvedge edge to the deckwith corrosion resistant roofing nails, nails & tin -tags or 1-inch diameter
plastic or steel cap nails spaced 24-inch o.c. for slopes below 7:12 and 12-inch o.c. for slopes 7:12 and greater.
Overlap successive courses the entire width of the black -selvedge area, minimum 3-inch.
Seal end (vertical) laps using SBS Mastic under all side (vertical) laps or any other laps where the self -adhering
bituminous underside is in contact with the granular or mineral top surface, rolling the interface into place with a
weighted roller, or using the Inverted Sheet Seam detailed in Boral Roofing published installation instructions.
6.6.4 Non -Tile Applications, to Base Sheet:
Install ASTM D226, Type 11 felt in accordance with Code requirements or install Citadel Plus in accordance with
Boral Roofing published installation instructions and Section 6.4.
Install GatorSeal over ASTM D226, Type II felt or Citadel Plus in accordance with Boral Roofing published installation
instructions and Section 6.6.3 except end (vertical) laps, described below.
Apply SBS Mastic under all side (vertical) laps or any other laps where the self -adhering bituminous underside is in
contact with the granular top surface, rolling the interface into place with a weighted roller.
6.7 Boral TileSeal"T or Boral MetalSeal"T:
6.7.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for
the type of prepared roof covering to be installed.
6.7.2 Do not use Boral TileSealw or Boral MetalSeal"T on roof pitches less than 2:12.
6.7.3 Non -Tile Applications. Direct to Deck:
For OSB substrate, prime with ASTM D41 primer and allow to dry prior to installation. Cut the membrane into
manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge, extending over by %-inch.
Fold the membrane away from the edge onto itself. Remove the release sheet. Place the membrane with the
exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a weighted roller.
Fasten the black selvedge edge to the deck with roofing nails, nails & tin -tags or 1-inch diameter plastic or steel
cap nails spaced maximum 12-inch D.C. Overlap successive courses the entire width of the black -selvedge area,
minimum 3-inch.
Seal under all end (vertical) laps using approved mastic or use Inverted Sheet Seam method detailed in Boral
Roofing published installation instructions.
NEW ETC, LLC Evaluation Report M35710.12.10-R31
Certificate ofAuthonzation #32455 0 EDITION (2017) FBC NON-HVHZ EVALUATION FL14317-RID
Boral Roof Underlayments; (602) 269-2Z88 Revision 11: 10/12/2018
Page 7 of 8
ONEMOletc.
6.7.4 Non -Tile Applications, to Base Sheet:
Install ASTM D226, Type II felt in accordance with Code requirements or install Citadel Plus in accordance with
Boral Roofing published installation instructions and Section 6.4.
Install Boral TileSealw or Boral MetalSeal"T over ASTM D226, Type II felt or Citadel Plus in accordance with Boral
Roofing published installation instructions and Section 6.7.3, except end (vertical) laps, described below.
Apply56S Mastic under all end (vertical) laps onany other laps where the self -adhering bituminous underside is in
contact with the fabric top surface, rolling the interface into place with a weighted roller.
6.7.5 Tile Applications:
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions
noted above as a guideline.
For mechanically fastened tile roofing over 2-ply system, consisting of Base Sheet and self -adhering top sheet(s),
Base Sheet fastening shall be not less than FRSA/TRI April 2012 (04-12), Table 1.
For adhesive -set tile applications, refer to Section 5.6.4 herein.
Note: For adhesive -set tile systems, if there is a base ply or mid -ply of Citadel Plus in the system, the project design
pressure requirements may not exceed -120 psf.
Refer to Section 5.8 for tile staging limitations. Battens must be used for all tile installations atop Boral TileSeaF
or Boral MetalSeal"T with roof pitches of 2%to less than 3:12. Boral Roofing's Elevated Batten System or counter
battens are required.
As required by the Building Official or Authority Having Jurisdiction in order to
this product.
8. MANUFACTURING PLANTS:
Brentwood,
UL, LLC. — QUA9625; (631) 546-2458; Kanchi.Agrawala-Dokania@ul.com
- END OF EVALUATION REPORT -
NEMO ETC, LLC Evaluation Report M35710.12.30-R31
certificate of Authorization #32455 6n' EDITION (2017) FBC NON-HVHZ EVALUATION FL14317-R10
Boral Roof Underlayments; (602) 269-2288 Revision 11: 10/12/2018
Page 8 of 8
EXTERIOR RESEARCH & DESIGN, U.C.
.. Certificate OfAuthori2Dtion 49503
SGANNty 353 CHRISTIAN STREET, UNIT #13
q0T�RINIfY �'E D BY OXFORD, CT 0647E
" St. Lucien County PHONE: (203) 262-9245
FAX: (203) 262-9243
EVALUATION REPORT
East Coast Metals, Inc. Evaluation Report E10240.08.08-R4
2301 West Lane FL5374-114
Hialeah, FL 33010 Date of Issuance: 09/03/2008
Revision 4: 03/17/2015
SCOPE:
This Evaluation Report is Issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with the 5`s Edition (2014) Florida Building Code sections noted herein.
DESCRIPTION: East Coast Metals Channel Metals
LABEONG: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the productchanges or the
referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by. the manufacturer or its
distributors and shall be available for inspection at the job site at the requestof the Building Official.
This Evaluation Report consists of pages 1 through 7.
Prepared by:
•9-"�s.<+.= —• +i.+E. Ilia hvim4e teals
Robert l.M.Nieminen,P.E. ''•o,.:
rS.°�t' ppearm8waaauthaued Robe,INkmmen, y r=!1:. ��r Tttls doeaoot tetreasa len,anka�Ma�Bned
Florida Registration No. 59166, Florida OCA ANE1983 tP.Eon0117/2015.dm;mn4Fned.ualetl lurdmpkx beve been mnsmittetlmtAe
`i'=Pa""'1^'�t produtt Approval Admindvatorandtmhe nan�eA client
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial Interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither Trinity ERD nor Robert Nleminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
�-TRINITYJERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Roofing Accessories that are an Integral Part of the Roofing System
Compliance Statement: East Coast Metals Channel Metals, as produced by East Coast Metals, have demonstrated compliance
with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance
is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section
Property
Standard
year
1507.3.7
Installation, non-HVHZ
FRSA/rRI April 2012(04-12)
2012
1518.8.1
Installation, HVHZ
RAS 118, 119 & 120
1995
1523.65.2.2
Static Uplift Resistance
TAS 101
1995
1711.2.1
Static Uplift Resistance
SBCCI SSTD 11
1997
3. REFERENCES:
Enti
Examination
Reference
Date
ERD(TST6049)
Static Uplift Resistance
E42730.08.13
08/23/2023
ERD(TSf6049)
Static Uplift Resistance
ECM-SC6795.12.14-1
02/27/2015
ERD(T5T6049)
Static Uplift Resistance
ECM-SC6795.12.14.2
02/27/2015
Florida TEC(TST7393)
TAS 101
51D-62811
10/27/2010
PRI (TST5878)
TAS 101
ECM-001-02-01
09/21/2001
PRI (TST5878)
TAS 101
ECM-003-02-01
06/13/2008
PRI (TST5878)
TAS 101
ECM-004.02-DS
O6/1312008
PRI (TST5878)
TAS 101
ECM-005-02.01
06/13/2008
PRI (TST5878)
TAS 101
ECM-006-02-01
06/13/2008
PRI (TST5878)
TAS 101
ECM-007-02-01
06/13/2009
PRI (TST5878)
TAS 101
ECM-008-02-01
06/2312008
Florida Building Code
Attachment Requirements
FRSA(TRI April 2012(04-12)
04/2012
Florida Building Code - HVHZ
Attachment Requirements
RAS 118, 119 and 120
1995
East Coast Metals
Metal Quality
Mill Certifications
Various
Architectural Testing(QUA1844)
Quality Control
Participation Letter
Exp. 12/31/2018
4. PRODUCT DESCRIPTION:
4.1 Hip & Ridge Channel Metal: Pre -formed metal channel
designed for use as a hip and ridge base to which roof tiles
are bonded in FBC Approved roof tile adhesive.
Hip & Ridge Channel Metal Is available in 119-3/8-Inch (+
3/8-inch) length by 2.5, 3, 3.5, 4, 5, 6 or 7-inch Lt 3/8-inch)
heights with 1.5-inch (±1/16-inch) deck -flanges.
Exterior Research and Design, LLG Evaluation Report E10240.09.08-R4
Certificate ofAuthorinufm A9S03 FL5374-R4
Revision 4:03/17/2015
Page 2 of 7
N4 . j INITY f ERD
4.2 Trim Lock Channel Metal: Pre -formed metal channel
designed for use as a hip and ridge base to which roof tiles
are bonded In FBC Approved roof tile adhesive. Trim Lock
Channel Metal is characterized by its profiled and
perforated upper horizontal flange designed to receive
and allow for interlock with the overlying tile adhesive.
Trim Lock Channel Metal is available in 119-3/8-inch
3/8") length by 3, 3.5, 4, 5 or 6-inch (± 3/8-inch) heights
with 1.5-inch (±1/16-inch) deck -flanges.
4.2 Trim Lock Plus Channel Metal: Pre -formed metal channel
designed for use as a hip and ridge base to which roof tiles
are bonded. in FBC Approved roof tile adhesive. Trim Lock
Plus Channel Metal is characterized by its profiled and
perforated upper horizontal flange designed to receive
and allow for Interlock with the overlying tile adhesive
and Its perforated deck flanges, designed for installation
atop the roof underlayment via placement In FBC
Approved roof tile adhesive, which flows -through and
Interlocks with the underlying adhesive.
Trim Lock Plus Channel Metal is available in 119-3/8-inch
L 3/8") length by 3, 3.5, 4, 5 or 6-inch (±3/8-inch) heights
with 1.5-Inch (±1/16-Inch) deck -flanges.
4.4 East Coast Metals Channel Metals are fabricated of the following metals:
> Galvanized Steel: Min. 0.019±0.002-inch, ASTM A653(G-90), min. 33 K51.
> Galvalume Steel: Min. 0.019±0.002-Inch, ASTM A792, AZ55, min. 35 KSI.
> Aluminum: Min. 0.032 ±0.002-inch, ASTM B209, 3003-1-114, min. 21 KSI.
> Stainless Steel: Min. 0.019±0.002-Inch, ASTM A240/A480, T304, min. 35 KSI.
S. LIMITATIoNs:
5.1 This is a building code evaluation. Neither Trinity)ERD nor Robert Nieminen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
Exterior Research and Design, LLC. Evaluation Report E30240.08.08-R4
CertifiWit ofAWhodratfm 99503 FL5374-114
Revision 4:03/17/2015
Page 3 of 7
`.I I KINITY ERD
5.2 FOR HVHZJURISDICfIONS:
5.2.1 For Hip & Ridge Channel Metal or Trim Lock Channel Metal, refer to FBC RAS 118, Drawing 13, Detail 3; RAS 119,
Drawing 12, Detail 3; or RAS 120, Drawing 15, Detail 3. For Trim Lock Plus Channel Metal, refer to the installation
instructions herein.
5.2.2 For HVHZ jurisdictions, Installations of Hip & Ridge Channel Metal and Trim Lock are prescriptive by RAS 118, 119 and..
120, and the data in Tables SA and 18 is supplemental to theseprescrtptive allowances.
Installations of Trim Lock Plus are limited to projects having a required moment resistance (M,) or uplift resistance (Frj,
as determined in accordance with RAS 127, not greater than the following values.
Refer to the tile adhesive manufacturer's published installation instructions for adhesive paddy placement details.
Y "INDEPENDENT' paddy placement means each individual tile Is bonded to the Channel Metal in Its own, single
foam paddy; the head laps are not bonded. This method is limited to 2-part tile adhesives. Allowable
performance data below for "INDEPENDENT" paddy placement already has a 2 to 1 margin of safety applied to
ultimate performance.
D "INTERDEPENDENT" paddy placement means each Individual the Is bonded to the Channel Metal in a foam paddy,
and a second foam paddy bonds the the head lap, or two tiles are bonded to the Channel Metal using a single
foam paddy. Allowable performance data below for "INTERDEPENDENT' paddy placement already has a 4 to 1
margin of safety applied to ultimate performance.
3y J { YI xi y Yt
1AeLF1AfP
RMwcEiMrtanoxs''#hfkiZ,fNMF
� ENOExtPAbpyP
it �p,�
�It {
g } '' Y, �f
1tXPi�`i"Afij .�-.�.m ''hard at1fS�i tL�`"..�..'fji#+:r�±iilrflAtkRGiN
OF'unEROIA�HiIp/d��... "#,.t}.rid.
t�3:'.:-.ss{�,'.i.�,'����(�ii,'„�'�'l a•'l.e
Hip/Ridge Metal
Tile
Adhesive
Allowable Performance
Design
Metal Type
Type
Placement
Moment Based
Uplift Based
M,(R-Ibf)
F'(Ibf)
Hip & Ridge
galvanized
dayor
3M" 2-Component Foam
Independent
127
169
Channel Metal
concrete
Roof Tile Adhesive AH-160
Trim Lock
galvanized, Galvalume•, -
clay or
3M"' 2-Component Foam
Independent
271
159
aluminum or stainless steel
concrete
Roof Tile Adhesive AH-160
Trim Lock Plus
galvanized, Galvalumee,
clay or
3M"' 2-Component Foam
Independent
177
165
aluminum or stainless steel
concrete
Roof Tile Adhesive AH-160
s }q 1111t i,(yff y,s s s }}h` fiABU B PERF9RT.t41K,
Il rf
+ �IM1iRdT10NSr'FI�!�Ij°ItiTE D pFNbEM PlA EHT kill$-} " '3+ ' `" r '�{+�f i..
r -�-�,., `
tijall q 1 ,„�.t
q 2aaiF*'1§ t�Jt)afty RP�ApO
,�i S ra j° !�''I€�
�
s rif- m,1 �a42 3xiz'}.i'..
i
f4m1 4AGIXOFSAiort AYYs(rEos -t att+liE, s.Se
Hip/RldgeMetal
Tile
Adhesive
Allowable Performance
Design
Metal Type
Type
Placement
Moment Based
Uplift Based
M,(ft-lbf)
F'(Ibf)
Trim Lock or Trim
galvanized, Galvalume•,
clay or
3M"'1-Component Foam
Lock Plus -
aluminum or stainless steel
concrete
Roof Tile Adhesive AN-160
Interdependent
95
88
Trim Lock
galvanized, Galvalume°,
clay or
31A ' Roof Tile Adhesive
Interdependent
99
94
stainless steel
concrete
RTA-1
Trim Lock
aluminum
clay or
3M"' Foam Roof Tile
Interdependent
90
84
concrete
Adhesive RTA-1
Trim lack Plus
galvanized, Galvalume•,
galvanized,
dayor
31v-Foam RoofTlle
Interdependent
90
84
orstainlesssteel
concrete
Adhesive RTA-1
Trim Lock
galvanized, Galvalume• or
clay or
TILE BOND"' Roof Tile
Interdependent
123
117
stainless steel
concrete
Adhesive
Trim Lock
aluminum
clay or
TILE BOND -Roof Tile
Interdependent
79
73
concrete
Adhesive
Trim Lock Pius
galvanized, Gahvalume•,
dayor
TILE BOND" Roof Tile
Interdependent
79
73
aluminum. or stainless steel
concrete
Adhesive
Tdm Lork
galvanized, Galvalume• or
dayor
Touch'n Seal StormBond
Interdependent
146
139
stainless steel
concrete
Roof Tile Adhesive
Trim lock
Aluminum
clay or
Touch'n Seal StormBond
Interdependent
58
54
concrete
Roof Tile Adhesive
Trim lock Plus
galvanized, Galvalumee,
day or
Touch'n Seal StormBond
Interdependent
58
54
aluminum or stainless steel
concrete
Roof Tile Adhesive
Exterior Research and Design, Lu: Evaluation Report E30240.08.08-R4
Certiifkate ofAUMcrketkm 89503 FL5374-R4
Revision 4:03/17/2015
Page 4 of 7
�,J � RINITY ERD
5.3 FOR NON-HVH2 JURISDICTIONS:
5.3.1 For Hip & Ridge Channel Metal or Trim Lock Channel Metal, refer to FRSA/TRI April 2012 (04-12). For Trim Lock Plus
Channel Metal, referto the installation instructions herein
5.3.2 For non-HVH2, installations are limited to projects having hip and ridge design pressure requirements, determined in
accordance with Table 1A of FRSA/TRI April 2012 (04-12), not greater than the following values. Refer to the tile
- adhesive manufacturer's published installation Instructions for adhesive paddy placement details. "
➢ "INDEPENDENT' paddy placement means each individual tile is bonded to the Channel Metal in its own, single
foam paddy; tile head laps are not bonded. This method Is limited to 2-part the adhesives. This method is limited
to 2-part tile adhesives. Allowable performance data below for "INDEPENDENT' paddy placement already has a 2
to 1 margin of safety applied to ultimate performance.
D "INTERDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in a foam paddy,
and a second foam paddy bonds the the head lap, or two tiles are bonded to the Channel Metal using a single
foam paddy. Allowable performance data below for "INTERDEPENDENT" paddy placement already has a 4 to 1
margin of safety applied to ultimate performance.
tsitsbnri,,J.,AeAP
OnNLD{ns�'or,HP_xrAoo�p- tiAaitYa'
M1md7at&
1T¢r;f
fatt
es;"a
Hip/Ridge Metal
Tile
Adhesive
- Allowable Uplift
(psf)
Design
Metal Type
Type
Placement
Hip & Ridge
Channel Metal
galvanized
clay or
3M" 2-Component Foam Roof
Independent
169
concrete
Tile Adhesive AH-160
Trim Lock
galvanized, Galvalume°, aluminum or
clay or
3M'" 2-Component Foam Roof
Independent
173
stainlesssteel
concrete
Tile Adhesive AH-160
Trim Lock Plus
galvanized, Galvalume", aluminum or
clay or
3M'" 2-Component Foam Roof
Independent
178
stainless steel
concrete
Tile Adhesive AH-160
)h F 2s " jyjzft 1z § Ti1dLE28 PERFORMANCE Idefir
Tloils'-#Nof3•H n i�'�E{ft1}(';ylFn��NS
y%If
rr,.. �y{,tiZpHt`nya(�r;x
TMReF4IT H�Ca
Hip/Ridge Metal
Tile
Adhesive
Allowable Uplift
(Psf)
Design
Metal Type
Type
Placement
Trim Lock or Trim
galvanized, Galvalume•, aluminum or
clayor
3M"'2-Component Foam Roof
Lock Pius
stainless steel
concrete
Tile Adhesive AH-160
Interdependent
98
Trun Lock
galvanized, Galvalume° or stainless
clayor
3M" Foam Roof Tile Adhesive
Interdependent
330
steel
concrete
RTA-1
Trim Lock
aluminum
clayor
3M"' Foam Roof Tile Adhesive
Interdependent
93
concrete
RTA-1
Trim Lock Plus
galvanized, Galvalume•, aluminum or
clay or
3M"' Foam Roof Tile Adhesive
Interdependent
93
stainless steel
concrete
RTA-1
Trim Lock
galvanized, Galvalume• or stainless
clayor
TILE BOND" Roof Tile Adhesive
Interdependent
152
steel -
concrete
Trim Lock
aluminum
clayor
TILE BOND"' Roof Tile Adhesive
Interdependent
82
concrete
Trim Lock Plus
galvanized, Galvalume•, aluminum or
clay or
TILE. BOND" Roof Tile Adhesive
Interdependent
82
stainlesssteel
concrete
Trim Lock
galvanized, Galvalume• or stainless
clayor
Touch'n Seal Storm Bond Roof
Interdependent
148
steel
concrete
Tile Adhesive
Trim lock
Aluminum
day or
ToucIn Seal StannSond Roof
Interdependent
61
concrete
Tile Adhesive
Trim Lack Plus
Galvanized, Galvalume•, aluminum or
clay or
Touch'n Seal Stormeond Roof
Interdependent
61
stainlesssteel
concrete
Tile Adhesive
Exterior Research and Design, LLC Evaluation Report E30240.08.08-R4
Certylrore ofAudwrizadon a9S03 FL5374•R4
Revision 4:03/17/2015
Page 5 of 7
`J TRINITY E�
6. INSTALLATION:
6.1 The roof deck shall be minimum 15/32-Inch plywood (non-HVHZ) or minimum 19/32-inch plywood (HVHZ) attached in
accordance with FBC Chapter 23 to the satisfaction of the AHJ.
6.2 Hip & Ridge Channel Metal and Trim Lock Channel Metal shall be installed using min. 11 ga. x 3Y-inch long x 3/8-inch
- head diameter galvanized annular ring shank nails spaced 6-inch o.c. along both deck -flanges. Fasteners shall be
positioned Y-inch from the outside edge of each deck -flange, set In a bed plastic roof cement. For FBC HVHZ, refer to
FBC RAS 118, Drawing 13, Detail 3; RAS 119, Drawing 12, Detail 3; or RAS 120, Drawing 15, Detail 3.
6.3 Trim Lock Plus Channel Metalshall be Installed atop the Approved roof underlayment in continuous 2-inch wide ribbons
of tile adhesive centered beneath each 1.5-Inch wide deck flange. Place the Trim Lock Plus Channel Metal into the wet
adhesive and allow it to set-up prior to installation of roof tiles.
View of Polyset AH160 Placement for Trim Lock Plus Channel Metal Installation
6.3.1 It is critical that the bond between the Trim Lock Plus Channel Metal, the tile adhesive and the underlayment is not
disturbed prior to or during placement of the ridge tiles.
6.3.2 Approved underlayments are the codified '30/90' system or other FBC Approved roof underlayments listing approved
use of the subject tile adhesive.
Exterior Research and Design, U.C. Evaluation Report E10240.08.08-R4
CerdprateolAud odunion 0003 FL53744t4
Revision 4:03/17/201S
Page 6 of 7
�J TRINITY I ERD
6.4 Tile shall be installed atop the Channel Metal in accordance with the the adhesive manufacturer's Approved, published
Installation Instructions, subject to the limitations outlined in Section 5 herein. The exposed edges shall be packed and
pointed with Approved mortar or weather blocking adhesive in accordance with FRSA/TRI April 2012 (04-12) or RAS
118, RAS 119, RAS 120 requirements.
Hip / Ridge Tile
Tile Adhesive
Trim Lock Plus
Mortar or Weather Block
Adhesive
Tile Adhesive
View of Trim Lock Plus Channel Metal Installation after Weather Blocked
6A.1 Channel Metal shall be free of dust, debris, oils or other bond -breaking substance prior to placement of adhesive.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
B. MANUFACTURING PLANTS:
Contact the named CIA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements.
9. QUALITY ASSURANCE ENTITY:
Architectural Testing, Inc. — QUA1844�(717) 764-7700
END OF EVALUATION REPORT -
Exterior Research and Design, U.C. Evaluation Report E10240.08.0&R4
Certf=re OfAurhodn0l.#9503 FL5374-R4
Revision 4:03/17/2015
Page 7 of 7