Loading...
HomeMy WebLinkAboutNOA'sREVMWED FOR� CODE®MP�.8A®�CE IAMI-DADECOUNTY MPAMI ST. LUCIE C®�� e O UCT CONTROL SECTION ®CC 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) ww•w.miamidade.eov/economy ICP Adhesives and Sealants, Inc. 12505 NW 441h Street .Coral Springs, FL. 33065 SCANNED BY SCOPE: St. Luce County This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: ICP Adhesives Polyset® AH-160 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA 16-0315.01 and consists of pages I through 11. The submitted documentation was reviewed by Alex Tigera. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 1 of 11 ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: :This -approves ICP Adhesives Polyset® AH460 as manufactured by ICP Adhesives and Sealants, Inc. as described,., in this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, do not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127. For use with approved flat, low, and high profile roof tile systems using ICP Adhesives Polyset® AH-160. PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Product Description Specifications ICP Adhesives N/A Polyset®AH-160 ICP Adhesives Foam N/A Dispenser RTF1000 ICP Adhesives ProPack® N/A 30 & 100 TAS 101 Two component polyurethane foam adhesive PRODUCTS MANUFACTURED BY OTHERS: Dispensing Equipment Dispensing Equipment Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment resistance values with the use of ICP Adhesives Polyset® AH-160 roof tile adhesive. MANUFACTURING LOCATION: Tomball, TX. PHYSICAL PROPERTIES: Property Test Density ASTM D 1622 Compressive Strength ASTM D 1621 Tensile Strength ASTM D 1623 Water Absorption ASTM D 2127 Moisture Vapor Transmission ASTM E 96 Dimensional Stability ASTM D 2126 Closed Cell Content ASTM D 2856 Results 1.6 lbs./ft.' 18 PSI Parallel to rise 12 PSI Perpendicular to rise 28 PSI Parallel to rise 0.08 Lbs./Ft' 3.1 Perm / Inch +0.07% Volume Change @ -401 F., 2 weeks +6.0% Volume Change @1580F., 100% Humidity, 2 weeks 86% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. MAMMADECOUNTY -U54 M NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 2 of 11 EVIDENCE SUBMITTED: Test Agency Center for Applied Engineering Miles Laboratories Polymers Division Ramtech Laboratories, Inc. Southwest Research Institute Trinity Engineering Celotex Corp. Testing Services Test Identifier #94-060 257818-IPA 25-7438-3 25-7438-4 '2'5-7438-7 25-7492 NB-589-631 9637-92 01-6743-011 01-6739-062b[1] 7050.02.96-1 P36700.04.12 P39740.02.12 528454-2-1 528454-9-1 528454-10-1 520109-1 520109-2 520109-3 520109-6 520109-7 520191-1 520109-2-1 Test Name/Report Date TAS 101 04/08/94 TAS 101 12/16/96 SSTD 11-93 10/25/95 SSTD'If93 "' 11/02/95"' SSTD 11-93 12/12/95 ASTM D 1623 02/01/94 ASTM E 108 04/30/93 ASTM E 108 11/16/94 ASTM E 84 01/16/95 TAS 114 03/14/96 ASTM D 1623 04/18/12 TAS 101 02/21/12 TAS 123 TAS 101 10/23/98 TAS 101 12/28/98 TAS 101 03/02/99 LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. ICP Adhesives Polyset® AH-160 shall solely be used with flat, low, & high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset® AH-160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 3 of 11 INSTALLATION: 1. ICP Adhesives Polyset® AH-160 may be used with any roof tile assembly having a current NOA that lists attachment resistance values with the use of ICP Adhesives Polyset® AH-160. 2. ICP Adhesives Polyset® AH-160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP Adhesives Polyset® AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value determiried in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. 3. ICP Adhesives Polyset® AH-160 and its components shall be installed in accordance with Roofing Application Standard RAS 120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained'Qualified Applicator' approved and licensed by ICP Adhesives and Sealants, Inc. ICP Adhesives and Sealants, Inc. shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the ICP Adhesives Foam Dispenser RTF 1000 dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0-1.15 (A): 1.0 (B). 6. ICP Adhesives Polyset® AH-160 shall be applied with ICP Adhesives Foam Dispenser RTF 1000 or ICP Adhesives ProPack® 30 & 100 dispensing equipment only. 7. ICP Adhesives Polyset® AH-160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes after ICP Adhesives Polyset® AH-160 has been dispensed. 9. ICP Adhesives Polyset® AH-160 placement and minimum patty weight shall be in accordance with the 'Placement Details' herein. Each generic tile profile requires the specific placement noted herein. Miarnrrrr NOA No.: 17-0322.03 •onoecou ,..., , Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 4 of 11 Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Minimum Paddy Contact Minimum Paddy Gram Area Weight Eave Course - Flat, Low, High All Eave Course 17-23 sq. inches 45-65 Profiles Flat, Low, High. Profiles #1 17-23 sq. inches' 45-65- Flat Profile #2 10-12 sq. inches 30 Low Profile #2 12-14 sq. inches 30 High Profile #2 17-19 sq. inches 30 Flat, Low, High Profiles #3 Two Paddys: 8-9 sq. inches at 12 grams per paddy head of tile 9-11 sq. inches at overlap Two -Piece Barrel (Cap Tile) Two Piece 2 Beads (1 each longitudinal 17 grams per bead edge) 20-25 sq. inches each bead Two Piece Barrel (Pan Tile) Two Piece 65-70 sq. inches 34 grams under pan LABELING: All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo and following statement: "Miami -Dade County Product Control Approved" or the Miami - Dade County Product Control Seal as shown below. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 5 of 11 ADHESIVE PLACEMENT DETAIL # 1 IBanaahrdai Oath[ s aptimal E.YeCourM Nall thro ihalastiC[emeM Faida le.o..eh7'd.l Urrd.rlsyva.err 8a 5 Baecourta Flat/Low Profile Tile 1. Starting at the cave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib closest to the overlock "'of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cmZ) — 23 (148.4 cmZ) square inch adhesive contact with the underside of the tile. Medium Profile / Double Pan Tile 1. Starting at the cave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm') — 23 (148.4 cmZ) square inch adhesive contact with the underside of the tile. High Profile / Single Pan Tile 1. Starting at the cave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm') — 23 (148.4 cmZ) square inch adhesive contact with the underside of the tile. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 6 of 11 through ptawc cement m mguiredl in. asamsuptivml ADHESIVE PLACEMENT DETAIL # 2 Flat/Low Profile Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the _,;,.,strengthening rib of the tile closest to„the overlock of - the tile being set. Insure approximately 17 (109.7 cmZ) — 23 (148.4 cmZ) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 10" (64.5 cm') - 12 (77.4 cm') square inch adhesive contact with the underside of the tile. Medium Profile / Double Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cmZ) — 23 (148.4 cm') square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 12" (77.4 cm2) - 14 (90.3 cm') square inch adhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 7 of 11 n ADHESIVE PLACEMENT DETAIL # 2 (CONTINUED) Wipedge High Profile / Single Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under -the pan portion of the tile closest to the Overlock of the tile being set. Insure approximately 17 (109.7 cm) — 23 (148.4 cm) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 17" (109.7 cmZ) - 19 (122.6 cmZ) square inch adhesive contact with the underside of the tile. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 8 of 11 ADHESIVE PLACEMENT DETAIL # 3 rain Flat/tow ProfileTlle Medium ProHleTlle 1. On the eave course only, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1"(25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib for flat tile or under the pan _ portion of the tile for low or high profile tile closest to the overlock of the tile being set. Leave approximately 4" (101.6 mm) up from the cave edge free of foam to prevent the expanded adhesive from blocking the weep holes. Insure approximately 17-23 in' (109.7-148.4 cm') of adhesive contact with the underside of the tile 2. Apply a 4" (101.6 mm) x 4" (101.6 mm) x 1" (25.4 mm) foam paddy onto the underlayment just below the second course line positioned foam paddy under the strengthening rib for flat tile, or under the pan portion of the tile, closest to the underlock for the second course tile to be installed. Insure approximately 8-9 in' (51.6-58.1 cmZ) of adhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 9 of 11 v Fare course ADHESIVE PLACEMENT DETAIL # 3 (CONTINUED) Nlgh ProflleTite 3. Also apply a 2" (50.8 mm) x 411(101.6 mm) x 3/d' (19 mm) paddy on top of the eave course tile surface as shown, on top of the strengthening rib for flat tile or on top of the pan portion of the tile, closest to the urderlock of the first course oftile. Install second course of tile. Insure approximately 9 (58.1 cmZ) - 11 (71cm2) square inch adhesive contact with the underside of the tile at the overlap and 7 (45.2 cmZ) - 9 (58.1 cmZ) square inch adhesive contact with the underside of the tile at the head of the tile. Continue in same manner. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 10 of 11 ADHESIVE PLACEMENT DETAIL TWO PIECE BARREL 11 Place enough adhesive to addeve65 to 70, In contact with the pan tile. ]) Yu rn coven upsidedown Place adhesve lit tot in.frommuldeedge ofcovartile>1412 Then install thedle.Ensure ]dto IUndedayment Fordo Remove top portion of the eave course cover tile. Abut to second worse of pan tiles. Emureeave end of pan and cover tiles areaushateeve line.. Two Piece Barrel - High Profile Tile Two Piece Barrel (Cap and Pan) Tile I. Starting at the eave course, apply a minimum 2" _ (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam _ paddy ohfo the underlayment positioned as shown under two adjacent pan tiles. Support eave tiles from rocking until adhesive has a chance to cure. 2. Continue in same manner bringing two pan courses up toward the ridge. Insure approximately 65 (419.4 cmZ) — 70 (451.6 cm?) square inch adhesive contact with the underside of the pan tile. 3. Turn covers upside down exposing the underside of the tile. Apply a minimum I" (25.4 mm) x 10" (254 mm) bead of adhesive directly on the inner edge of each side of the cover tile. Leave approximately 3/4" (19 mm) to 1" (25.4 mm) from the outside edge of the tile, inward, free of foam to allow for expansion. 4. Turn cover tile over after foam is applied and place onto pan tile course. Insure a minimum of 20 (129 cm') - 25 (161.3 cm') square inch contact area on each side of the cover tile to the pan tile. Continue in same manner. Trim away any cured exposed foam adhesive. Pointing of longitudinal edges of the cover tiles are considered optional. 5. When additional nailing is required, 2" (50.8 mm) x 4" (101.6 mm) milers or the tie wire system using galvanized, stainless steel, or copper wire and compatible nails may be used. END OF THIS ACCEPTANCE NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 11 of 11 REVMWED FOR CODE COMPLIANCE hllAMliau ST. LUCIE Cqq��OUNTY DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) The Quikrete Companies, LLC. SCANNED5. Concourse Parkway, Suite 1900 - - Atlanta, GA. 30328 BY St. LucieCounty MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T(786)315-2590 F (786) 315-2599 www.miamidade.gov/economy SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION:_ QUIKRETE® Roof Tile Mortar FL-15 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA 18-1129.04 and consists of pages 1 through 6. The submitted documentation was reviewed by Alex Tigera. NOA No.: 19-0226.08 Expiration Date: 11/06/24 Approval Date: 04/18/19 Page 1 of 6 ROOFING COMPONENT APPROVAL: Cateaorv: Roofing Sub Cate¢orv: Roofing Tile Adhesives Materials: Cement SCOPE: This approves QUIKRETE® Roof Tile Mortar FL-15 as -manufactured by The Quldete Companies, LLCr as: described in this Notice of Acceptance. PRODUCTS MANUFACTURED BY OR LABELED BY APPLICANT: Test Product Dimensions Specifications Product Description QUIKRETE® Roof Tile 80 lb. bags TAS 123 Premixed pre -bagged gray roof tile mortar for Mortar FL-15 use with approved roof tiles in accordance with RAS 120 MANUFACTURING LOCATIONS: 1. Miami, FL 2. Lakeland, FL 3. Jacksonville, FL 4. Ft. Myers, FL. EVIDENCE SUBMITTED: Test A2encv Test Identifier Test Name/Revort Date Center for Applied Engineering Metro Dade Protocol TAS 101 Florida Testing and Engineering, hic. ASTM C 91 Type M PRI Construction Materials Technologies TAS 123 QKT-003-02-01 10/15/09 TAS 123 QKT-004-02-02INT 10/23/14 TAS 123 QKT-007-02-01 06/26/15 Construction Technology Laboratories, Inc. ASTM C 270 385045 06/14/10 NOA No.: 19-0226.08 MLAMMADECOUMn Expiration Date: 11/06/24 Approval Date: 04/18/19 Page 2 of 6 LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. Field uplift testing shall be performed, in accordance with the test procedures set forth in Roofing Application Standard TAS 106. Testing shall be performed not prior to 30 days after installation. 3. Quikrete® Roof Tile Mortar FL — 15 shall be placed in a 5" x 12" pad at time of application. The mortar pad placement shall be in accordance with the Placement Details' provided herein. Each generic tile profile requires a specific.placement, (see Placement Detail listed herein). 4. Quikrete® Roof Tile Mortar FL - 15 shall be applied in accordance with The Quikrete Companies, LLC's specifications. 5. Tile must be applied within 5 minutes of the application of Quikrete® Roof Tile Mortar. FL — 15. 6. Refer to the tile manufacturer's Miami -Dade County Product Control Notice of Acceptance for system approvals. 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. 5. All bags shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility, and. following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. INSTALLATION: 1. Quikrete® Roof Tile Mortar FL - 15 and its components shall be installed in strict compliance with Roofing Application Standard RAS 120. 2. Mortar placement shall be in accordance with the placement details specified below. PLACEMENT DETAILS TILE PROFILE: DETAIL NO. Medium Profile A Flat Profile B High Profile C BUILDING PERMIT REQUIREMENTS: 1. As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 19-0226.08 Expiration Date: 11/06/24 Approval Date: 04/18/19 Page 3 of 6 90k MINERAL ROOFING FASCIA PLACEMENT DETAIL "A11 MORTAR PLACFMFNT ROLL TILE PLACEMENT DETAIL "B" NOTE. MORTAR CONTACT IS RACE WITH S TILES. x0SMALL SLID ILET INER V. EVI CYS C OR ux TO ONC E RLOCN DE ACYCENT TILE. " T INC HEADTHE TILE 2, THE YNOERLCCK SIDE U. 17 ETILEBEIONC i HE EO AOLNAHLIIG is REOU IR O sv CODE) MINERA FAC RSCR CLT AL EAVE ➢RI .�. THICKBUTT THLEL - Ul SCHEMATICSAW H W N TILE AND MORTAR PLACEMENT - FLAT TILE NOA No.: 19-0226.08 Expiration Date: 11/06/24 Approval Date: 04/18/19 Page 4 of 6 PLACEMENT DETAIL "C" FASTENER AND SEALANT ON CAP SHEET (WHEN REQUIRED) OVERLAP MORTAR PADDY � I / ROLLED GABLE (SPANISH "S" CUTS) WEEP HOLE L EA4E CLOSURE POINT MORTAR TO FINISH NOA No.: 19-0226.08 Expiration Date: 11/06/24 Approval Date: 04/18/19 Page 5 of 6 PLACEMENT DETAIL "C" (CONTINUED) COVER NAILER BOARD (WHEN REQUIRED) PAN MORTAR PLACEMANT FASTENER AND SEALANT OR CAP SHEET (WHEN REQUIRED) FASTENER AND SEALANT OR CAP SHEET (WHEN REQUIRED) / — MORTAR BED WEEP HOLE —' AND POINT TO FINISH END OF THIS ACCEPTANCE NOA No.: 19-0226.08 Expiration Date: 11/06/24 Approval Date: 04/18/19 Page 6 of 6 (CODE COMPLIANCE .. ST. LUC�IE COS NTY MIAMI-DADECOUNTY MIAMI•QADE _ po PRODUCT CONTROL SECTION SOCC 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/eennomv Boral Roofing, LLC 7575 Irvine Center Drive, Suite 100 Irvine, CA 92618 SCABNVNED St. LucieCounty SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Estate "S" Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply.with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 16-0112.08 and consists of pages 1 through 7. The submitted documentation was reviewed by Freddy Semino a NOA No.18-0829.03 Expiration Date: 08/23/21 Approval Date: 10/11/18 Page 1 of 7 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub Category: Roofing Tiles Material: Concrete 1. SCOPE This approves a roofing system using Boral Estate "S" Concrete Roof Tile, as manufactured by Boral Roofing, LLC in Okeechobee, FL as described in Section 2 of this Notice of Acceptance, designed to comply with the Florida Building Code for High Velocity Hurricane Zone. For use in locations where the pressure requirements, as determined by applicable Building Code, do not exceed the design pressure values obtain by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be prepared as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Dimensions Test Product Applicant Specifications Description Boral Estate `S' Roof Tile Length = 16-1/2" TAS 112 Low profile, interlocking, extruded Width = 13" Type lb concrete roof tile equipped with two nail Class III hole and double roll ribs. For direct deck or battened nail -on, mortar or adhesive set applications. Trim Pieces I = varies TAS 112 Accessory trim, concrete roof pieces for w = varies use at hips, rakes, ridges and valley varying thickness terminations. Manufactured for each tile profile. 2.1 MANUFACTURING LOCATION 1. Okeechobee, FL 2.2 PRODUCTS MANUFACTURED BY OTHERS Product Name ICP Adhesives Polyset® AH-160 TILE BOND' Roof Tile Adhesive DAP Foam Touch N Seal StormBond® 2 Roof Tile Adhesive Product Description Two component polyurethane foam adhesive. Single component polyurethane foam roof tile adhesive. Two component polyurethane foam adhesive. Manufacturer (With Current NOA) ICP Adhesives and Sealants, Inc. The Dow Chemical Company Dap Foam, Inc. NOA No. 18-0829.03 Expiration Date: 08/23/21 Approval Date: 10/11/18 Page 2 of 7 2.3 EVIDENCE SUBMITTED: Test Agencv Test Identifier Test Name/Report Date Redland Technologies 7161-03 PA 102 Dec. 1991 7161-03 PA 102(A) Dec.1991 7161-03 PA 108 Dec.1991 P0402 Withdrawal Resistance Testing of Sept. 1993 screw vs. smooth shank nails P0631-01 PA 108 July 1994 Letter Dated Aug. 1, PA 108 Aug. 1994 1994 Professional Service Industries, Inc. 224-47099 PA 112 Sept. 1994 The Center for Applied 94-060B PA 101 March, 1994 Engineering, Inc. 94-084 PA 101 May 1994 25-7094-1 PA 102 Oct. 1994 25-7094-7 PA 102 Oct. 1994 25-7094-4 PA 102 Oct. 1994 Project No.307025 PA 100 Oct. 1994 Test #MDC-76 25-7183-1 PA 102 Feb. 1995 25-7183-2 PA 102 Feb. 1995 25-7214-2 PA 102 March, 1995 25-7214-6 PA 102 March, 1995 Celotex Corporation Testing Services 528454-2-1 PA 101 Sep. 1998 520109-2 Dec. 1998 Walker Engineering, Inc. Calculations Aerodynamic Multiplier March 1999 IBA Consultants, Inc. 2381-264 TAS 112 01/08/08 American Test Lab of South Florida RT1210.03-15 TAS 112 12/17/15 PRI Construction Material DAPF-004-02-05 TAS 101 07/26/18 Technologies DAPF-004-02-07 Static Uplift Resistance 07/26/18 (Adhesive Set) 3. LIMITATIONS: 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance with TAS 106 may required, refer to applicable building code. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Miami -Dade Product Control Section for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. NOA No.18-0829.03 Expiration Date: 08/23/21 Approval Date: 10/11/18 Page 3 of 7 .-t 3.7 All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. 4. INSTALLATION 4.1 Boral Estate "S" Concrete Roof Tile and its components shall be installed in strict compliance with Miami Dade County Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations. Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight-W (lbf) Length4 (ft.) Width-w (ft.) . Boral Estate'S' Roof Tile 10.0 1.375 1.08 Table 2: Aerodynamic Multipliers - 2, (ft3) Tile Profile 1 (ft3) Batten Application % (ft3) Direct Deck Application Boral Estate'S' Roof Tile 0.267 0.289 Table 3: Restoring Moments due to Gravity - Ma (ft.-lbf) Tile Profile 3":12" 4":12" 5":12" 611:12" Greater than 7":12" Boral Estate'S' Roof Tile Battens Direct I Deck Battens Direct I Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck 5.91 6.74 5.82 6.64 5.70 6.50 5.56 6.33 5.40 1 6.14 Tile Fastener Type Profile Roof Tile I 1-10d Smooth or Screw zDmoom or: Shank Nails 1-10d Smooth or Screw Shank Nail (Field Clip)Z 1-10d Smooth or Screw Shank Nail (Eave CIiD1Z 2-10d Smooth or Screw :a9 Shank Nails esistance Expressed as a Moment - Mr (ft-lbf) for Nail -On Systems Direct Deck Direct Deck (min 16/32" plywood) (min. 19/32" plywood) 27.8 37.4 8.8 11.8 16.4 21.9 24.3 35.5 31.9 43.0 47.1 24.3 35.5 31.9 3M 28.8 4.1 7.1 22.9 49.1 24.2 22.1 32.2 NOA No.18-0829.03 Expiration Date: 08/23/21 Approval Date: 10/11/18 Page 4 of 7 I Installation with a 4" the headlap and fasteners are located a min. of 2%" from head of tile. 2 When using only one fastener use the hole that is approximately 4-3/4" away from interlocking edge. Table 5: Attachment Resistance Expressed as a Moment Mf (ft.-Ibf), for Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Boral Estate'S' Roof Tile Adhesive' 3 See manufactures component approval for installation requirements. 4 The Dow Chemical Co. TILE BONDT"' Roof Tile Adhesive weight per patty 11.4 grams. 26.1 5 ICP Adhesive and Sealants, Inc. ICP Adhesve Polyset® AH-160 Two -Component weight per patty 8 grams 26.1 6 DAP Foam Touch N Seal Storm Bond® 2 Roof Tile Adhesive weight per paddy 8 grams. 35.0 Table 6: Attachment Resistance Expressed as a Moment - Mf (ft.-Ibf) for Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Boral Estate'S' Roof Tile Adhesive' 7 See manufactures component approval for installation requirements. 8 ICP Adhesive and Sealants, Inc. ICP Adhesve Polyset® AH-160 Two -Component weight per patty 54 grams. 86.61 9 ICP Adhesive and Sealants, Inc. ICP Adhesve Polyset® AH-160 Two -Component weight per patty 24 grams 45.5 10 DAP Foam Touch N Seal Stonn Bond® 2 Roof Tile Adhesive weight per paddy 60 grams. 60.0 Table 7: Attachment Resistance Expressed as a Moment - Mf (ft.-Ibf) for Mortar or Adhesive Set Systems Tile Tile Application Minimum Attachment Profile Resistance Boral Estate 'S' Roof Mortar Set 20.60 Tile NOA No.18-0829.03 Expiration Date: 08/23/21 Approval Date: 10/11/18 Page 5 of 7 5. LABELING All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as seen below or following statement: "Miami -Dade County Product Control Approved". m ENTEGRA Q!!7 BORAL ESTATE "S" TILE LABEL (LOCATED ON UNDERSIDE OF TILE) 6. BUILDING PERMIT REQUIREMENTS: 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this system. NOA No.18-0829.03 MIAMMADECoufm Expiration Date: 08/23/21 6 1 Approval Date: 10/11/18 Page 6 of 7 Nail Holes PROFILE DRAWING two BORAL ESTATE "S" CONCRETE ROOF TILE END OF THIS ACCEPTANCE A NOA No. 18-0829.03 Expiration Date: 08/23/21 Approval Date: 10/11/18 Page 7 of 7