Loading...
HomeMy WebLinkAboutFIELD DENSITY TESTFEDERAL •DEL 0 ENGINEERING & TESTING 1798 AGORA CIRCLE S.E. SUITE 5 250 S.W. 13'H AVENUE PALM BAY, FLORIDA 32909 U !1 b _ V 3U POMPANO BEACH, FLORIDA 33069 SCANNED FIELD DENSITY TESTS OF COMPACTED SOILS BY - S4. Lucie County - DATE: 12/21/07 ORDER NO: 07-3435 PERMIT NO. 07100308 CLIENT:- CORAL POOLS ADDRESS: 885 1 OTH AVENUE SW, VERO BEACH, FLORIDA 32962 PROJECT: AMBERCROMBE RESIDENCE PROPOSED POOL POOL DECK ADDRESS: 5501 EMERSON, FORT PIERCE, FLORIDA MATERIAL DESCRIPTION: BROWN SILICA SAND W/TRACES OF SHELL FRAGS LOCATION: E.S. OF POOL DECK LIFT 1 LOCATION: E.S. OF POOL DECK LIFT 2 LOCATION: W.S. OF POOL DECK LIFT 1 LOCATION: W.S. OF POOL DECK LIFT 2 LOCATION: N.S. OF POOL DECK LIFT 1 LOCATION: N.S. OF POOL DECK LIFT 2 FIELD DENSITY METHOD AS.T.M. D-2922 DRY DENSITY P.C.F. IN THE FIELD - 107.0 106.4 106.1 104.4 105.2 105.0 • MOISTURE 9.0 8.7 9.6 9.3 9.2 8.4 • COMPACTION 1N THE FIELD 97.6 97.0 96.8 95.2 95.9 95.8 • COMPACTION REQUIREMENT 95% �VE� 2 8 2007 PROCTOR VALUE, P.C.F. 109.7 OPTIMUM MOISTURE, % 12.9C�y LABORATORY NO. P-2285 PROCTOR A.S.T.M D-1557 METHOD PISTIB REMARKS: SOIL NOT TESTED BELOW FOOTERS TESTED BY: SL Respectfully submitted, CHECKED BY: KM / � / ISSAM S. N AbN�/P!%E. As a mutual protection to clients, the public and ourselves, all reports FEDERAL ENGINEERING & TESTING are submitted as the confidential property of clients, and authorization FLORIDA REG. #39584 for publication ofstatements, conclusions or extracts from or regarding our reports is reserved pending our written approval. \ A density test determines the degree of compaction of the tested layer ofmaterial only. A density does not replace a soil bearing capacity determination.