Loading...
HomeMy WebLinkAboutLETTERS FROM BRADEN & BRADENSCANNED BY St. Lucie County SkAOEN-6«$t}ADEN, A. 1. A., P. A. �rchlfecfs 8t 91anners 417 OOOONUT ANLE, S UART• FLOROA 34 S6 TELEPHONE 17721 267-9258 FA% •7721 287�283 #AA -aDC C:32 April 16, 2013 County Building Department Permrt tk 1303-0105 P& Residence for Marcello Mr. Roseberry, Please note, the following revisions have bcen made based on plan review (Y)mments. - The girder strapping has been revised on the roof plan. At truss point 2 on truss Al (which sets on the %%wxl Ix -am) the strap shall be (2) Simpson HTS 20 straps withstanding Q3001hs naax. combined At truss point 15 (which sets on the blx-k wall) the stntp shall be Simpson AWT installed with (1) Ur threaded rod set 12" into beam and nailed per Simpson req. for a mac uplift resistao(r of 3565 lbs The strap at truss point 12 shall be the standard IlYrA & This has been sluow2u on the roof plan. If you have any questions please feel free to call me at (772) M7-&'5& WRBradeu Braden & Braden AIA PA m d m J A N -B BRADEN 6. BRADEN, A. I. A., P. A. Irchllecfs & 91annem 417 COCONUT AVENUE, STUART, FLORIOA 34996 TELEPHONE: (772) 297-6256 FAX (7721 2B7-62B3 #AAC-000032 April 16, 2013 County Building Department Permit#. 13 63 — 0169 RE: Residence for Marcello Mr. Roseberry, Please note, the following revisions have been made based on plan review comments - The girder strapping has been revised on the roof plan. At truss point 2 on truss Al (which sets on the wood beam) the strap shall be (2) Simpson HTS 20 straps withstanding 2300 lbs may. combined. At truss point 15 (which sets on the block wall) the strap shall be Simpson MCP installed with (1) 5/8" threaded rod set 12" into beam and nailed per Simpson req. for a max uplift resistance of 3965 lbs. The strap at truss point 12 shall be the standard BETA 20. This has been shown on the roof plan. - Also added to the drawings is a column cap detail showing the connection of the rear porch beams to the rear corner column. It has been noted on the roof plan and shown on sheet D-2. Please see the sealed plans attached this submittal for the sheets stated above. If you have any questions please feel free to call me at (772) 287-8258. bab-u—n isUa Braden& Braden AIA PA �� � 'ffilI B DEN & BRADEN, A. I. A., R. A. Architects & nJ lanners 417 COCONUT AVENUE, STUART, FLORIDA 3499B TELERHONE: (772) 2S7-B25B FAX (772) 2B7-B283 #AAC-0O0032 SEPTEMBER 25, 2013 Marcello 1848 Wildcat Cove Drive Permit # 1303-0185 Dear Building Department. Please allow the bracing detail provided by the truss company to supersede the detail for truss bracing we provided on our drawings. Sincerely, AIA !n AIA PA SCANNED BY St. Lucie County To: St Lucie County, Building Dept. 2300 Virginia Ave. Fort Pierce, FL 34982 Re: Permi # 1303-0Dce firmation #445 The M 1848 Wildcat Cove Dr Fort Pierce FL Use this letter as notification that the HVAC sub will be ACR Services Inc. Delete Associated Air Of Port St Lucie Inc. Sincerely, n M Cherveny CBC #046609 08%28I2013 `µ Phone: 772-287-03901 fax: 772-283-09871 www.homesbyjmc.com b4;MNM BY LETTER bPl+ 'I SMITTAL Kamer Surveying, Inc. 2740 SW Martin Dooms Blvd. 8333 Palm City, FL 34990 (772)-288-7206 (772)-223-8181 SCANNED BY St. Lucie Counts Send to: St Lucie Cou tanning & DevelopmeV ' Provided via: , ODVirginiaAvee -- nu Sent via e-mail - April 14, 2014 Fort Pierce, FL 34982 Sent via UPS - April 14, 2014 From: KamerSurveying,inc. Regina Kamer, PSM Attention: Lydia Galbraith `: ' Date: April 14, 2014 Legal Description: RIVERPOINTE ATTHE SANDS, PHASE Regarding: Final/As Built Survey and FEMA Revisions TWO, Lot 43, St Lucie County, Florida Job Number. 1301.29 rormck-up ❑ Urgent ❑ Reply ASAP ❑ Please comment Please review Forycurinformation Enclosed, please find the following: • Three copies of the REVISED Final/As Built Survey, as requested, for the above referenced property. • Two REVISED FEMA Elevation Certificates. Sincerely, Sue Fox-@ Kanner Surveying, Inc.