HomeMy WebLinkAboutGLASS PAPERWORKArchitectural Railing Division
C.R.Laurence Co., Inc.
2503 E Vernon Ave.
Los Angeles, CA 90058
BY
"NED
St. ud Nnf ftl
SUBJ: GRS — GLASS RAIL SYSTEM —
WET GLAZED OR TAPER -LOCO SYSTEM DRY -GLAZED
BASE SHOES
19 June 2014
The GRS Glass Rail System utilizes an aluminum extruded base shoe to anchor and
support structural glass balustrades which support a variety of top rails and grab rails
to construct guards and dividers. The glass may be installed in the base shoe using
either wet glazing cement or the Taper -Loco System Dry -Glaze as detailed in this report.
The system is intended for interior and exterior weather exposed applications and is
suitable for use in most natural environments. The GRS may be used for residential,
commercial and industrial applications except for vehicle impacts. The GRS is
designed for the following:
On Cap/Top/Grab Rail:
Concentrated load = 2001bs any direction, any location EVIEWE� FOR
Uniform load = 50 plf, any direction perpendicular to ra�
On In -fill Panels: ;ODE COMPLIANCE
Concentrated load = 50# on one sf. ST. LUCIE COUNTY
Distributed load = 25 psf on area of in -fill, including spaces
Wind load = As stated for the application and components (ASD 1 vel)
The GRS system will meet all applicable requirements of the 2012 and 2009 International
Building Code and state codes adopted from them, 2010 and 2013 California Building Code,
Florida Building Code, and 2012 and 2009 International Residential Code. The GRS System
complies with ASTM E 2358-04 Standard Specification for the Performance of Glass in
Permanent Glass Railing Systems, Guards, and Balustrades. Aluminum components are
designed in accordance with the 2005 Aluminum Design Manual. Stainless steel
components are designed in accordance with SEI/ASCE 8-02 Specification for the Design
of Cold -Formed Stainless Steel Structural Members. Wood components are designed in
accordance with the National Design Specification for Wood Construction. Glass lights are
designed in accordance with AAMA CW 12-84 Structural Properties of Glass. When
constructed as recommended the guards will meet the testing requirements of ICC AC
439 Acceptance Criteria for Glass Railing and Balustrade System, ASTM E-2353-06 Standard
Test Methods for Performance of Glass in Permanent Glass Railing Systems, Guards and
Balustrades. This report is in support of the the approval of the system in ESR-3269.
EDWARD C. ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329 FI�-F ,r nov
253-858-0855/Fax 253-858-0856 elrobison@narrows.com
C.R. Laurence Glass Rail System (GRS) and Taper-Loc@ 06/19/2014 Page 2 of 55
This report demonstrates the structural adequacy of the various base shoe options,
mounting options and three monolithic tempered glass options. For a complete code
compliant installation an appropriate cap/top rail or grab rail shall be installed, refer to
the Glass Rail System Cap Rails and Grab Rails report for design information on the cap
rails and grab rails.
In accordance with -IBC 1607:8.1 guard live loads are not to be combined with other
transient loads such as wind loads. Wind
loads, seismic loads and live loads may be
considered separately and independently.
Dead loads are to be considered when acting
cumulatively with a transient load condition. For installations covered in this report
dead load effects are negligible and are typically ignored.
CONTENTS:
Item
Page
Signature Page
3
Typical Installations
4-9
Taper-Loc® System Typ Install
10
Load Cases
11
Wind Loading
12
Glass Strength
13 — 17
Taper-Loc® Dry Glaze System
18 - 21
Base shoe B5S
22 - 27
Base shoe B5L
28 - 33
Base shoe B5T
34
Base Shoe B5A SurfaceMate
35 - 36
Base Shoe B5G Green Base Shoe
37
Base Shoe 8B Series Square Cored
38
Base Shoe B6S
39 - 41
Base shoe B7S
42 - 45
Drain Blocks
46 - 49
Weld Blocks
49
Concrete Anchor adjustments
49
Surface Mounting to Wood
50
Aluminum Angle bracket for mounting to wood.
51 - 52
Steel Angle bracket for mounting to wood.
53
Surface mounting to wood -interior only
54
Installation on Stairs
55
EDWARD C. ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329
253-858-0855/Fax 253-858-0856 elrobison@narrows.com
C.R. Laurence Glass Rail System (GRS) and Taper-Loc® 06/19/2014
Signature Pia -'signed 06/25/2014
Texas Firm # 12044
Edward C. Robison, P.E.
DBA: E & L Civil Engineering
10012 Creviston DR NW
Gig Harbor, WA 98329
Page 3 of 55
ROBISON
ENp 72/31/201
FIRM #F-12044
EXP 12/31/2014
/PUCiUgq-"%s
z ;EDWARD Ct
u ; ROBISON ;
8100707�
- Z OF ILA"
EXP 11/30/2014
EDWARD C. ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329
253-858-0855/Fax 253-858-0856 elrobison@narrows.com
C.R. Laurence Glass Rail System (GRS) and Taper -Loco 06/19/2014
Page 4 of 55
Tvuical Installations
Glass Taper -Loco System or wet -glazed into base shoe. An appropriate top rail or grab rail shall
be used. Residential, Commercial and Industrial Applications:
ALL WIND LOADS IN THIS REPORT ARE BASED ON ASD WIND PRESSURES.
SURFACE MOUNTED:
Surface mounted to steel with 1h" cap screws @ 12" o.c.: A
1/2" cap screw to steel 36" Height 42" Height
Base Shoe - - Allowable wind load*
BSA, B5G, B5S, B5T, 8B 75.3 psf 55.3 sf
B5L 67.7 psf p
B6S 78.9 p 49.8 psf
psf 58.0 psf
B7S 82.8 psf 60.9 psf
Surface mounted to steel with'h" ca screws @ 6" o.c.: A
1/2" cap screw to steel
Base Shoe
36" Height
42" Height
Allowable wind load*
BSA, B5G, B5S, B5T, 8B
150.0 psf
110.2 psf
B5L
B6S
134.5 psf
98.8 sf
p
B7S
157.2 psf
p
115.5 psf
165.1 psf
*Allowable wind load may be limited by glass strength.
121.3 psf
For anchorage to concrete Surface Mounted
3 3/8 diameter x 4" Hilti HUS-EZ (KH-EZ) in accordance with ESR-3027 or Hilti HSL-3 M8 x
3-3/4" anchor in accordance with ESR-1545. Pc = 3,000 psin
embed depth = 2.5" effective depth
Concrete anchors a 3.75" edge distance ABc
Anchor spacing to concrete 12" O.C.
Total Guard Height AFF 36" 42"
Base Shoe Allowable wind load Allowable wind load
B5G, 135S, B5T, 8B 42.7 psf 31.4 sf
BSA 41.2 psf p
B5L 39.0 P 30.3 psf
psf 28.6 psf
B6S 45.6 psf 33.5 psf
B7S 47.9 psf 35.2 psf
Anchor spacing to concrete 6" O.C.Ano
Total Guard Height AFF 36" 42"
B5G, 135S, B5T, 8B 68.6 psf 50A psf
BSA 66.9 psf 49.2 psf
B5L 61.5 psf 45.2 psf
B6S 73.2 psf 53.8 psf
B7S 75.7 psf 55.6 psf
EDWARD C. ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329
253-858-0855/Fax 253-858-0856 elrobison@narrows.com
C.R. Laurence Glass Rail System (GRS) and Taper-Loc@
06/19/2014
Surface Mounted Base Shoes:
Concrete anchors z 235" edge distance ABC
Anchor spacing to concrete 12" O.C.
Total Guard Height AFF 36"
42"
e Base Shoe Allowable wind load
Allowable wind load
B5G, B5S, 135T, 8B 35.5 psf
26.1 psf
B5A 34.0 psf
25.0 psfa
B5L (3.047" min edge dist) 35.4 psf
26.0 psfa
B6S 37.2 psf
27.3 psf
B7S 39.1 psf
28.7 psf
aDoesn't meet 50 plf live load on top rail
Concrete anchors � 1 75" edge distanceABC
Anchor spacing to concrete 6" O.C.
Total Guard Height AFF
36"
42"
B5G, B5S, B5T, 8B
50.8 psf
37.3 psf
B5A
B5L
49.9 psf
36.6 psf
B6S
45.6 psf
33.5 psf
B7S
53.3 psf
53.3 psf
B7S 2.35" edge distance
56.0 psf
61.9 psf
41.1 psf
45.5 psf
Page 5 of 55
A Linear interpolation between guard heights, anchor spacing and edge distances is permitted.
$Adjustment for concrete strength other than V. = 3,000 psi
W' = W*-/X
✓3,000
'Adjustment for sand light -weight concrete:
W' = 0.6*W
SURFACE MOUNTED WITH DRAIN BLOCKS ON CONCRETE
Concrete anchors L 3.7511 edge distance ABC
Anchor spacing to concrete 12" O.C.
Total Guard Height AFF 36" 42„
Base Shoe Allowable wind load Allowable wind load
B5G, B5S, B5T, 8B 41.2 psf 30.2 psf
B5A 41.2 psf 30.2 psf
B5L 37.0 psf 27.2 psf
136S 44.0 psf 32.3 psf
B7S 50.5 psf 37.1 psf
ALL WIND LOADS IN THIS REPORT ARE BASED ON ASD WIND PRESSURES.
EDWARD C. ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329
253-858-0855/Fax 253-858-0856 elrobison@narrows.com
C.R. Laurence Glass Rail System (GRS) and Taper-Loc@ 06/19/2014
SURFACE MOUNTED WITH DRAIN BLOCKS ON CONCRETE
Anchor spacing to concrete 6" O.C.ABC
Total Guard Height AFF
36"
42"
BSG, BSS, BST, 8B
66.9 psf
49.2 psf
B5A
66.9 psf
49.2 psf
B51,
60.2 psf
44.2 psf
B6S
71.2 psf
52.3 psf
B7S
74.6 psf
54.8 psf
Concrete anchors a 235" edge distance ABC
Anchor spacing to concrete 12" O.C.
Total Guard Height AFF
36"
42"
Base Shoe
Allowable wind load
Allowable wind load
BSG, BSS, BST, 8B
34.0 psf
25.0 psfa
B5A
34.0 psf
25.0 psfa
B51, (3.047" min edge dist)
30.6 psf
26.9 psfa
B6S
36.2 psf
26.6 psf
B7S
41.6 psf
30.5 psf
aDoesn't meet 50 plf live load on top rail add extra anchor
per 10' length
Concrete anchors 2t 235" edge distance ABC
Anchor spacing to concrete
6" O.C.
Total Guard Height 42" above finish floor.
BSG, BSS, BST, 8B
55.0 psf
40.4 psf
B5A
55.0 psf
40.4 psf
B5L
49.5 psf
36.4 psf
B6S
58A psf
42.9 psf
B7S
61.2 psf
45.0 psf
Page 6 of 55
A Linear interpolation between guard heights, anchor spacing and edge distances is permitted.
$Adjustment for concrete strength other than f', = 3,000 psi
W' = W*-,/x
✓3,000
cAdjustment for sand light -weight concrete:
W' = 0.6*W
ALL WIND LOADS IN THIS REPORT ARE BASED ON ASD WIND PRESSURES.
EDWARD C. ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329
253-858-0855/Fax 253-858-0856 elrobison@narrows.com
C.R. Laurence Glass Rail System (GRS) and Taper-Loc®
06/19/2014
FASCIA (SIDE) MOUNTED BASE SHOE
Fascia mounted to steel with 'A" cap screws @ 12" o.c.:
1/2" cap screw to steel 36" Height
42" Height
Base Shoe Allowable wind load*
BSA, BSG, BSS, 8B 68.7 psf
51.2 psf
B5L 47.5 psf
35.3 psf
B6S 68.7 psf
51.2 psf
B7S 68.7 psf
51.2 psf
Fascia mounted to steel with %,, cap screws @ 6" o c
1/2" cap screw to steel 36" Height
42" Height
Base Shoe Allowable wind load*
BSA, BSG, BSS, 8B 138.2 psf
103.0 psf
B5L 95.6 psf
71.2 psf
B6S 138.2 psf
103.0 psf
B7S 138.2 psf
103.0 psf
*Allowable wind load may be limited by glass strength.
Height is from top of base shoe to top of rail.
Page 7 of 55
For anchorage to concrete•
3/8" diameter x 4" Hilti HUS-EZ (KH-EZ) in accordance with ESR-3027 or Hilti HSL-3 M8 x
3-3/4" anchor in accordance with ESR-1545. f'c = 3,000 psi
embed depth = 2.5" effective depth
Fascia Mounted
Concrete anchors edge distance t % base shoe height
Anchor spacing to concrete 12" O.C.
Total Guard Height AFF 36"
Base Shoe Allowable wind load
BSA, BSG, BSS, 8B 49.7 psf
B5L 42.0 psf
B6S 49.7 psf
B7S 49.7 psf
Anchor spacing to concrete 6" O.C.
Total Guard Height 42" above finish floor.
BSA, BSG, BSS, 8B 77.1 psf
B5L
B6S
51.0 psf
77.1 psf
B7S 77.1 psf
Height is from top of base shoe to top of rail.
42"
Allowable wind load
37.0 psf
31.2 psf
37.0 psf
37.0 psf
57.5 psf
37.9
57.5 psf
57.5 psf
ALL WIND LOADS IN THIS REPORT ARE BASED ON ASD WIND PRESSURES.
EDWARD C. ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329
253-858-0855/Fax 253-858-0856 elrobison@narrows.com
C.R. Laurence Glass Rail System (GRS) and Taper-Loc@ 06/19/2014
Fascia Mounted
To wood with T' lag screws with 2.37" minimum embedment to wood G
Anchor spacing 12" O.C. Interior or Dry locations me 519 %
Total Guard Height AFF 36" 42„
Base Shoe Allowable wind load Allowable wind load
BSA, BSG, BSS, 8B 48.7 psf 36.3 psf
B5L 41.4 psf 30.8
B6S 48.7 psf 36.3 psf
B7S 48.7 psf 36.3 psf
Anchor spacing 6" O.C.
Total Guard Height AFF 36" 42"
BSA, BSG, BSS, 8B 92.6 psf 69.0 psf
B5L 77.8 psf 57.9 psf
B6S 92.6 psf 69.0 psf
B7S 92.6 psf 69.0 psf
Anchor spacing 12" O.C. Exterior or wet locations where me a 19 %
Total Guard Height AFF 36" 42"
Base Shoe Allowable wind load Allowable wind load
BSA, BSG, BSS, 8B 34.5 psf 25.7 psf
B5L 29.4 psf 21.9
B6S 34.5 psf 25.7 psf
B7S 34.5 psf 25.7 psf
Anchor spacing to 6" O.C.
Total Guard Height AFF 36" 42„
BSA, BSG, BSS, 8B 66.9 psf 49.9 sf
B5L 56.8 psf p
B6S 66p 42.2 psf
.9 psf 49.9 psf
B7S 66.9 psf 49.9 psf
Height is from top of base shoe to top of rail.
Page 8 of 55
ALL WIND LOADS IN THIS REPORT ARE BASED ON ASD WIND PRESSURES.
EDWARD C. ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329
253-858-0855/Fax 253-858-0856 elrobison@narrows.com
C.R. Laurence Glass Rail System (GRS) and Taper-Loc® 06/19/2014 Page 9 of 55
Surface mounted to wood
Refer to Surface Mounting Base Shoes to Wood Decks section of this report.
Embedded base shoe:
All base shoes: Glass strength controls for all cases when base shoes are properly embedded into
concrete.
OTHER GLASS HEIGHTS•
The allowable wind loads may be adjusted for other light heights by:
W' = W42*422
Hg2
inches. Where Hg = total guard height measured from bottom of base shoe to top of cap rail in
ALLOWABLE LOADS ON GLASS
Glass thickness
Allowable wind load
36" Guard Height 42"
Guard Height
1/2"
71.1 psf
52.2 psf
5/8"
114A psf
84.1 psf
3/4"
167.1 psf
122.8 psf
MINIMUM RECOMMENDED GLASS LIGHT WIDTH
Glass thickness
36" Guard Height 42"
Guard Height
1/2"
2'- 6"
2'- 10.5"
5/8"
V- 7" -
11- 10"
3/4"
11- 0„
1'- 3"
Glass thickness shall be selected as required to achieve the required wind load.
For guard installations using monolithic tempered glass a cap/top rail or grab rail shall be
installed supported by a minimum of 3 glass lights or otherwise supported so as to remain
in place in the event of any single glass light failure.
Linear interpolation of all tables is permitted'.
ALL WIND LOADS IN THIS REPORT ARE BASED ON ASD WIND PRESSURES. If
using wind loads calculated per ASCE/SEI 7.10 the strength level wind loads must be
adjusted by multiplying by 0.6 per ASCE/SEI 7-10 section 2A load combinations and
HIC 1605.3.1.
EDWARD C. ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329
253-858-0855/Fax 253-858-0856 elrobison@narrows.com
C.R. Laurence Glass Rail System (GRS) and Taper-Loc® 06/19/2014 Page 10 of 55
Taper-Loc® System Typical Installation
. ,,..lam ruiiy remperea Mass maximum glass light height = 42":
Edge Distance: 2" s A s 8 5/8"; 51mm s A s 219mm
Center to center spacing: 7" s B s 14": 178min s B 5 356mm
Panel Width/Required quantity of Taper-Loc® Plates:
6" to 14"
(152 to 356mm)
1 TL Plate
14" to 28"
(356 to 711 mm)
2 TL Plates
28" to 42"
(711 to 1,067 mm)
3 TL Plates
42" to 56"
(1,067 to 1,422 mm)
4 TL Plates
56" to 70"
(1,422 to 1,778 nun)
5 TL Plates
70" to 84"
(1,778 to 2,134 mm)
6 TL Plates
84" to 96"
(2,134 to 2,438 mm)
7 TL Plates
Minimum Glass Light Width = 6" when top rail/guardrail is continuous, welded corners or
attached to additional supports at rail ends.
NOTES:
1. For glass light heights over 42" Amax and Bme shall be reduced proportionally.
Amax = 8 5/8*(42/h)
B,u = 14*(42/h)
2. For glass light heights under 42" Amax and B.a shall not be increased.
3. Amin and Bmin are for ease of installation and can be further reduced as long as proper
installation is achieved.
4. For glass thicknesses greater than 1/2" Am= and Bma may be increased as follows:
5/8" Glass
Edge Distance: 2" s A s 13.5"
Center to center spacing: 7" s B s 21"
3/4" Glass
Edge Distance: 2" 5 A s 19"
Center to center spacing: 7" 5 B s 31"
EDWARD C. ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329
253-858-0855/Fax 253-858-0856 ehrobison@narrows.com
C.R. Laurence Glass Rail System (GRS) and Taper-Loc® 06/19/2014
LOAD CASES:
Dead load = 6.5 psf for glass
1.8 plf top rail
8.6 plf for base shoe
Loading:
Horizontal load to base shoe
25 psf*H or W*H
Balustrade moments
Mi = 25 psf*H2/2 or
Mom, = w psi* H2/2
For top rail loads:
Mc = 200#*H
M. = 50plf*H
Three options for glass thickness:
1/2" glass, weight = 6.46 psf
5/8" glass, weight = 8.04 psf
3/4" glass, weight = 9.35 psf
EDWARD C. ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329
253-858-0855/Fax 253-858-0856 elrobison@narrows.com
Page I 1 of 55
C.R. Laurence Glass Rail System (GRS) and Taper-Loc@ 06/19/2014 Page 12 of 55
WIND LOADING
For wind load surface area is full area of guard:
Calculated in accordance with ASCE/SEI 7-05 Section 6.5.14 Design Wind Loads on Solid
Freestanding Walls and Solid Signs (or ASCE/SEI 7-10 Chapter 29A). This section is
applicable for free standing building guardrails, wind walls and balcony railings that return to
building walls. Section 6.5.12.4A (29.6) Parapets may be applicable when the rail is along a
roof perimeter. Wind loads must be determined by a qualified individual for a specific
installation.-
p = gp(GCP) = gzGQ (ASCE 7-05 eq. 6-26 or 7-10 eq. 29.4-1)
G = 0.85 from section 6.5.8.2 (sec 26.9.4.)
Cf= 2.5*0.8*0.6 = 1.2 Figure 6-20 (29.4-1) with reduction for solid and end returns, will vary.
Q: = KXvKdVzI Where:
I =1.0
K� from Table 6-3 (29.3-1) at the height z of the railing centroid and exposure.
Kd = 0.85 from Table 6-4 (Table 26-6).
Kzt From Figure 6-4 (Fig 26.8-1) for the site topography, typically 1.0.
V = Wind speed (mph) 3 second gust, Figure 6-1 (Fig 26.5-1A) or per local authority.
Simplifying - Assuming 1.3 5 Cf 5 2.6 (Typical limits for fence or guard with returns.)
For Cf = 1.3: F = qh*0.85*1.3 = 1.11 qh
For Cf = 2.6: F = qh*0.85*2.6 = 2.21gh
Wind Load will vary along length of fence in accordance with ASCE 7-05 Figure 6-20 (29A-1).
Typical exposure factors for K, with height 0 to 15' above grade:
Exposure B C D
K= = 0.70 0.85 1.03
Centroid of wind load acts at 0.55h on the fence.
Typical wind load range for I = 1.0 and K,, = 1.0 Wind loads are ASD level
Table 1: Wind load in psf Cf =13 Wind load in psf G = 2.60 `
Wind Speed B C D B C D
V 0.00169V2 0.00205V2 0.00249V2 0.00337V2 0.00409Vz 0.00495V2
85 12.2 14.8 17.9 24.3 29.5 35.8
90 13.7 16.6 20.2 27.3 33.1 40.1
100 16.9 20.5 24.9 33.7 36.9 49.5
110 20.5 24.8 30.1 40.7 49.5 59.9
120 24.3 29.6 35.8 48.5 58.9 71.3
130 28.6 34.7 42.0 56.9 69.1 83.7
140 33.1 40.2 48.8 66.0 80.1 97.1
Where fence ends without a return the wind forces may be as much as 1.667 times Ct=2.6 value.
When I = 0.87 is applicable (occupancy category n multiply above loads by 0.87.
For wind loads based on ASCE 7-10 wind speeds, figures 26.5-1A, B and C, multiply the wind
loads by 0.6 to convert to Allowable Stress Design loads.
For example - Exp B with Cf = 1.3; 7-05 wind speed = 85 mph w= 12.2 psf:
7-10.wind speed= 110mph w = 0.6*20.5 = 12.3 psf (ASD wind loads typically used herein)
MINIMUM WIND LOAD TO BE USED IS 10 PSF.
EDWARD C. ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329
253-858-0855/Fax 253-858-0856 elrobison@narrows.com
C.R. Laurence Glass Rail System (GRS) and Taper -Loco 06/19/2014
GLASS BALUSTRADE GUARD RAIL
GLASS STRENGTH
All glass is fully tempered glass conforming to the specifications of
ANSI Z97.1, ASTM C 1048-04 and CPSC 16 CFR 1201. For fully
tempered glass the average Modulus of Rupture Fr is 24,000 psi. The
Safety Factor of 4.0 used herein is based on IBC Section 2407 and is
applicable to live loads only. Wind load stress may be increased in
accordance with IBC 2404.1 and ASTM El300 to a maximum allowable
edge stress of 10,600 psi (9,600 psi recommended for most
installations).
Glass lights serve as balusters to support the top rail or grab rail and
form the guard infill.
Allowable glass bending stress: 24,000/4 = 6,000 psi. — Tension stress
calculated from live loads.
Bending strength of glass for the given thickness:
S = 12"* (t)z = 2* (t)2 in3/ft
6
Use minimum glass thickness.
For 1/2" glass S = 2*(0.469)2 = 0.44 in3/ft
Maw;ve = 6,OOOpsi*0.44 in3/ft = 2,640"#/ft = 220'#
Mauwiad = 9,600psi*0.44 in3/ft = 4,224"#/ft = 352'#
Page 13 of 55
For continuously supported cantilevered elements basic beam theory for cantilevered beams is
used.
Ma = u*h2/2 for uniform load W and height h or
MP = P*h for concentrated load P and height h,
For wind load centroid acts at 0.55h:
Mw = w*h2*0.55 for uniform load W and height h or
For deflection: t is average glass thickness, E = 10.4x106 psi
A _ (1-vz)wh4/(8Et3); w = uniform load on glass or
0 = (1-v2)uh3/(3Et3); u = distributed load on top rail or
0 = (1-v2)Ph3/(3EI); P = concentrated load on top rail,
I = bt3 where b is glass width in feet.
ASTM E 2358-04 limits deflection to h/12 (3.5" for 42" guard height). For comfort level it is
recommended to limit deflection to 1" for 42" guard height. The IBC has no defined deflection
limit.
For glass wet glazed in base shoe stress is uniform across light. For the Taper -Loco system the
stress may be assumed as uniform as demonstrated later in this report.
EDWARD C. ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329
253-858-0855/Fax253-858-0856 elrobisonCnarrows.com
C.R. Laurence Glass Rail System (GRS) and Taper-Loc® 06/19/2014
Page 14 of 55
GLASS PANELS LOADS:
From UBC Table 16-B or IBC 1607.7.1
On hand rail — 2001b concentrated or 50 plf Any direction
Or On panel — 25 psf horizontal load
DETERMINE MAXIMUM PANEL HEIGHT 1h" glass:
For 50 plf distributed load:
L--= (M/w)= 220#'/50pif = 4.4' = 52-3/4"
Maximum Panel height for 25 psf live load
L = (220#'*2/25 psf)1/z = 4.20' = 50-3/8" (1/2" glass cantilevered)
for 30 psf:
L = (220#'*2/30 psf)1/2 = 3.83' = 46"
Maximum wind load based on glass strength
w = (352#')/(0.55h2)
Glass light height = 36"
Calculate maximum wind load:
w = (352#1)/(0.55*32) = 71.1 psf
150 mph exposure D - depends on specific site conditions
Glass light height = 42"
Calculate maximum wind load:
w = (352#')/(0.55*3.52) = 52.2 psf
140 mph exposure C or 130 mph exposure D - depends on specific site conditions
Determine maximum glass light height for 150 mph exposure D wind, w= 58.7 psf
It = -✓(352#'/(0.55*58.7) = 3.302' = 39.62"
Maximum guard total height = 39.62"+ 4" = 43.62" for 58.7 psf.
For 200 lb concentrated load
Worst case is load at end of panel top corner with
no top rail:
The load will be initially resisted by a strip = 8t
For 1/2" glass = 4"
The shear will transfer along the glass at a 45° angle
from vertical to spread across the panel.
b2 = bI+h*tan45
@ 2" from top
M = 200#*2" = 400#"
S = 0.22 in3 based on 6" width
fn = 400#11/0.22 in3 = 1,818 psi
Determine minimum panel width for 42" height
EDWARD C. ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329
253-858-0855/Fax 253-858-0856 elrobison@narrows.com
C.R. Laurence Glass Rail System (GRS) and Taper-Loc@ 06/19/2014
(38" glass cantilever height)
M = 200#*38" = 7,600#"
S = 0.44 in3/ft and Fb = 6,000 psi
Im;o = (7,600/(6,000*0.44) = 2.88'
Page 15 of 55
Deflection: 42" total height, 38" glass height.
A = Ph3/(3Ebt3) = 200*38"3/(3*10,400,000*2.88'*0.53) = 0.98" (200# load min width)
A = uh3/(3Et3) = 50plf*38" 3/(3 * 10,400,000*0.53) = 0.70" (50 plf load)
A = wh4/(8Et3) = 50psf/12*38" 4/(8*10,400,000*0.53) = 0.84" (50 psf wind load)
NOTE: FOR THE TAPER-LOC® SYSTEM INSTALLED WITHOUT WET GLAZING GLASS
LOADS TYPICALLY DO NOT NEED TO BE ADJUSTED FOR STRESS
CONCENTRATIONS AS DEMONSTRATED LATER IN THIS REPORT.
For 518" glass
S = 2*(0.595)2 = 0.708 in3/ft
Mautive = 6,000psi*0.708 in3/ft = 4,248#"/ft = 354.0#'
Mallwlnd = 9,600psi*0.708 in3/ft = 6,797#"/ft = 566.4#'
DETERMINE MAXIMUM PANEL HEIGHT 5/8" glass:
For 50 plf distributed load:
L = (M/w)= 354.0#'/50pif = 7.08'
Maximum Panel height for 25 psf live load
L = (354.0#' *2/25 psf)1i2 = 5.32' (5/8" glass cantilevered)
Maximum wind load based on glass strength
w = (354.0#' *2)/(h2)
h = ✓(354.0#' *2/w)
For surface mounted base shoe:
Glass light height = 36"
Calculate maximum wind load:
w = (566.4#1)/(0.55*32) =114.4 psf
Glass light height = 42"
Calculate maximum wind load:
w = (566.4#')/(0.55*3.52) = 84.1 psf
Determine maximum glass light height for 150 mph exposure D wind, w= 58.7 psf
h = ✓(566.4#'/(0.55*58.7) = 4.189'= 4' 21/4"
Maximum guard total height = 50 1/4"+4" = 54 1/4" = 4' 61/4" for 58.7 psf.
Minimum width for 200# concentrated live load and 42" guard (38" glass) height:
lmio = (7,600/4,248) = 1.789'
EDWARD C. ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329
253-858-0855/Fax253-858-0856 elrobison@narrows.com
C.R. Laurence Glass Rail System (GRS) and Taper-Loc@ 06/19/2014
Page 16 of 55
Deflection: 42" total height, 38" glass height.
A = Phi/(3Ebt3) = 200*38113/(3*10,400,000*1.789'*0.6253) = 0.8" (200# load min width)
A = uh3/(3Et3) = 50plf*38"3/(3*10,400,000*0.6253) = 0.36" (50 plf load)
A = wh4/(8Et3) = 50psf/12*38"4/(8*10,400,000*0.6253) = 0.43" (50 psf wind load)
For_3/4"—glass -- —
S = 2*(0.719)2 = 1.034 in3/ft
Maiaive = 6,000psi* 1.034 in3/ft = 6,204"#/ft = 517'#
Mauwind = 9,600psi*1.034 in3/ft = 9,926"#/ft = 827.2'#
DETERMINE MAXIMUM PANEL HEIGHT 3/4" glass:
For 50 plf distributed load:
L = (M/w)= 517.0#'/50pif = 10.34'
Maximum Panel height for 25 psf live load
L = (517.0#' *2/25 psf)tiz = 6.43' = 6` - 5" (3/4" glass cantilevered)
Maximum wind load based on glass strength
w = (517#')/(0.55h2)
h = ✓[517#'/(0.55w)]
For surface mounted base shoe:
Glass light height = 36"
Calculate maximum wind load:
w = (827.2#')/(0.55*32) = 167.1 psf
Glass light height = 42"
Calculate maximum wind load:
w = (827.2#')/(0.55*3.52) = 122.8 psf
Determine maximum glass light height for 150 mph exposure D wind, w= 58.7 psf
h = ✓(827.2#'/(0.55*58.7) = 5.062'= 5' 3/4" = 60.75"
Maximum guard total height = 60.75"+4" = 64.75" = 5' 4.75" for 58.7 psf.
Minimum width for 200# concentrated load and 42" guard (38" glass) height:
lmin = (7,600/(6,204) = 1.225'
Deflection: 42" total height, 38" glass height.
A = Ph3/(3Ebt3) = 200*38"3/(3*10,400,000*1.225'*0.753) = 0.68" (200# load min width)
A = uh3/(3Et3) = 50plf*38113/(3 * 10,400,000*0.753) = 0.21" (50 plf load)
A = wh4/(8Et3) = 50psf/12*38"4/(8* 10,400,000*0.753) = 0.25" (50 psf wind load)
EDWARD C. ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329
253-858-0855/Fax 253-858-0856 elrobison@narrows.com
C.R. Laurence Glass Rail System (GRS) and Taper-Loc@ 06/19/2014
Page 17 of 55
WIND BORNE DEBRIS
Glass Guards located in Wind -Borne Debris Region - IBC 1609.2
When design for large missile impact loading as described in ASTM E 1996 to comply with IBC
1609.1.2 or Test Protocol Test Application Standard (TAS) 201-94 to comply with Florida
Building Code Section 1626 is required laboratory testing may be required to verify system
performance. Typically 3/4" or thicker laminated tempered glass is required to resist the missile
--impact-for 42"-guard height.
The need for compliance with these tests is dependent on the local jurisdiction and is beyond the
scope of this report. Typically since the guards are not part of the building envelope the testing is
not required but when located within a wind-borne debris region consultation with the local code
authority is recommended before specifying a specific glass section and the appropriate base
shoe.
GLASS LIGHT SPACING
Glass light spacing must be adequate to assure that no direct contact occurs between the glass
edges from either differential glass deflections or thermal expansion.
Thermal Expansion of glass:
v = 5x10-6 in/(in F')
For a typical 150F' maximum temperature range and 72" maximum glass light length:
8 = 5x10-6 in/(in F°)* 150F°*72" = 0.054"
Recommended minimum specified spacing is 1/4" (%" for''/a" glass).
Glass fabrication tolerances may result in spacing smaller than specified. As -installed spacing
less than 0.054" is unacceptable and should not be permitted.
GLASS FLATNESS
ASTM C 1048 Heat Treated Flat Glass - Kind HS, Kind FT Coated and Uncoated Glass allows
0.08" bow for 35" to 47" width. Installer should try to align bows to reduce the misfit between
lights. Out of plane variation between glass lights is unavoidable but may be reduced by
specifying vertically treated glass and installing glass with the tong marks inserted into the base
shoe.
EDWARD C. ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329
253-858-0855/Fax 253-858-0856 elrobison@narrows.com
C.R. Laurence Glass Rail System (GRS) and Taper -Lac@ 06/19/2014 Page 18 of 55
DRY -GLAZE TAPER -LOCO SYSTEM
Glass is clamped inside the aluminum base shoe by the Taper -Loco Shoe Setting Plate (L shaped'
piece on the back side) and two Taper -Loco Shim Plates (front side). The glass is locked in place
by the compressive forces created by the Taper -Loco shim plates being compressed together by
the installation tool. Use of the calibrated installation tool assures that the proper compressive
forces are developed. Until the shim plates are fully installed the glass may be moved within the
base shoe for adjustment.
Glass may be extracted by reversing the installation tool to extract tapers.
EDWARD C. ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329
253-858-0855/Fax 253-858-0856 elrobison@nar-ows.com
C.R. Laurence Glass Rail System (GRS) and Taper-Loc® 06/19/2014 Page 19 of 55
The Taper-Loc® setting plate is bonded to the glass by adhesive tape to hold it in place during
installation and to improve glass retention in the base shoe.
Surface area of the setting plate adhered to the glass:
A = 2"*3.5" = 7 inz
adhesive shear strength > 80 psi
3MTM VHB Tape_
Z = 7 in2*80 = 560# minimum
setting plate locks into place in the base shoe by friction created by the
compression generated when the shim plates are locked into place.
Installation force:
Tdes = 250#" design installation torque
Tmu = 300#" maximum installation torque
Compressive force generated by the
installation torque:
C = (0.2*250#"/1.0")/ sin(1.76°)
C = 1,628#
Frictional force of shims and setting plate
against aluminum base shoe:
coefficient of friction, µ= 0.65
f= 2*(1,628#0.65) = 2,117#
Frictional force of shims against glass:
µ = 0.36
f=1,628*0.36 = 586#
Resistance to glass pull out:
U = 586#
Safety factor for 200# pullout resistance = 586/200 = 2.93 For single set.
Minimum recommended installation torque:,
4/(2*2.93)*250 = 170#"
Extraction force required to remove tapers after installation at design torque:
T = 250*(0.7/0.2) = 875#"
EDWARD C. ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329
253-858-0855/Fax 253-858-0856 elrobison@narrows.com
C.R. Laurence Glass Rail System (GRS) and Taper-Loc@ 06/19/2014 Page 20 of 55
Glass anchorage against overturning:
Determine reactions of Taper-Loc® plates on the glass:
Assuming elastic bearing on the glass fiber reinforced
polycarbonate parts the reactions will have centroids at
approximately 1/6*2.55" from the upper and lower edges of
the bearing surfaces:
Rc, @ 1/6*2.55 = 0.425"
From 21M about Rca = 0
0 = M+V*(0.425"0.5") - Rca *1.7"
Where M = V*38"
substitute and simplify:
0 = V*38.925" - Rca *1.7"
Solving for - Rca
RcB = V*38.925/1.7 = 22.9V
For CB = 3,000 psi:
Rca = 3.5"*(2.55"/2)*3,000 psi/2 = 6,694#
V. = 6,694/22.9 = 292#
Ma = Rce*(2/3*2.55") = 11,380#"
Rca = Rca +V = 6,694+292# = 6,986#
At maximum allowable moment determine bending in base shoe legs:
Ms = C*(0.188+2.55"/2) + Rca *(0.188+2.55-0.425) _
Ms = 1,954*(1.463) + 6,986 *(2.313) = 19,017#"
Base shoe tributary length of leg that resists bending from load:
L = 3.5"+8*0.5"+2*(3.25") = 14", This is the maximum allowable spacing of the Taper-Loc@
system so represents the maximum loading condition.
Strength of leg 14" length = 14,062#"* 14/12 = 16,406#"
Adjustment to allowable load based on base shoe strength:
Ma = 16,406/19,017* 11,380 = 9,818#"
Allowable Moment per lineal foot of glass rail:
Ma=9,818*12/14= 8,415#"
EDWARD C. ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329
253-858-0855/Fax 253-858-0856 elrobison@narrows.com
C.R. Laurence Glass Rail System (GRS) and Taper-Loc® 06/19/2014 Page 21 of 55
GLASS STRESS CONCENTRATION FROM TAPER -LOCO SYSTEM
The Taper -Loco System provides a concentrated support:
Stress concentration factor on glass based on maximum 14" glass width to each Taper -Loco set.
Moment concentration factor
CM =[I+(I-a/b)2(1-C/b)?(1-t/b)1/3]1/2
a = 2.75" (bottom of glass to top of bearing)
b = center to center spacing of supports or width.of
glass.
c = length of bearing
glass thickness will have less than 1 % change in the
stress concentration so can be ignored for the three
glass thicknesses.
CM=[l+(1-2.75/14)z(1-3.5/14)3(1-.5/14)1/3]1/2 = 1.13
b/h=14"/35" = 0.4" < I based on maximum spacing of 14" and glass height of 35" (36" rail)
CM, = 1+(CM—1)*(b/h)3 = 1.008
Since adjustment is typically under 1% it can be ignored when glass height exceeds 21" when
CM, < 1.04
Fb = 6,000
Shear concentration factor:
Cv = 14"/3.5"*(2-3.5/14) = 7.0
Fva = 3,000 psi maximum allowable shear stress
Allowable Glass Loads:
Ma = S*6,000/1.13
Va = t*b/7.0
For 1/2" glass, 14" high x14" TaperLoc spacing - CM, =1.13:
Ma = 0.44*6,000/1.13 = 2,336"#=194.7#
Va = 0.5*14*3,000/7.0 = 3,000#
Since shear load in all scenarios is under 10% of allowable it can be ignored in determining
allowable bending since it has less than I% impact on allowable bending loads or rail heights.
Maximum edge distance for edge of glass to centerline of Taper -Loco plates:
edes = 14/2 = 7" for design conditions (no reduction in allowable loads)
emu = e + edes/2: (25*e*3.5')+25*1.17*3.52/2 = 229.6 : solve for e
emu = 3.5" + [229.6 - 25* 1.17*3.5z/2]/(25*3.5) =10.4" (to CL of Taper -Loco plates)
EDWARD C. ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329
253-858-0855/Fax 253-858-0856 elrobison@narrows.com
C.R. Laurence Glass Rail System (GRS) and Taper-Loc@ 06/19/2014
B5S 2 1/2" X 41/8" GLASS BALUSTRADE BASE SHOE
6063-T52 Aluminum extrusion
Fully tempered glass glazed in place by wet glazing cement or
dry glazed with Taper-Loc®
Shoe strength — Vertical legs:
Glass reaction by bearing on legs to form couple. Allowable
moment -on legs:
Ma = Si*Ft or F.
Ft = Fe = 12.5 ksi (ADM Table 2-23, Sec 3.4.4 and 3 A.13)
Si = 12"*0.75" 2*/6 = 1.125 in3/ft
Ma = 12.5 ksi*1.125 in3/ft = 14,062#"/ft
Leg shear strength @ groove
tmin = 0.343"
Fv= 5.5 ksi (ADM Table 2-23, Sec 3.4.20
Vaii = 0.75"*l2"/ft*5.5 ksi = 49.5 k/ft
Base shoe anchorage:
Typical rail section: 42" high
panel load
50 plf top rail load or 25 psf
Mt = 50plf*42" = 2,100"#/ft
Mw = 25 psf*3.5'*21" = 1,837.5"#
Typical Anchor load — 12" o.c. — Ta = 2,100"#/1.25" = 1,680#
Page 22 of 55
For 1/2" cap screw to tapped steel, CRL Screw part SHCS 1204 or SHCS 12x 1
T. = Asn*tc*0.6*Fta
where tc = 0.25"; As = 1.107" and Ft. = 58 ksi (A36 steel plate)
Tn = 1.107"*0.25*0.6*58 ksi = 9.63 k
Bolt tension strength = 0.75*67.5 ksi*0.1419 in2 = 7.18 k
Since shear load is under 0.2* shear strength (Va = 2.7k) interaction can be ignored.
Use 5/16" minimum for maximum load:
Maximum service load: 7.18k/2 = 3,592#
Maximum allowable moment for 12" on center spacing and direct bearing of base shoe on steel:
M = 3,592#*[1.2511-0.5*3,592/(30ksi*12)] = 4,470"# = 372.5'# per anchor
Maximum allowable wind loads'%" cap screws at 12" o.c. to structural steel.
36" height: w = 372.5#'/(0.55*32) = 75.3 psf
42" height: w = 372.5#'/(0.55*3.52) = 55.3 psf
Spacing for full strength of %" glass = 4,470/6,797*12" = 7.89" o.c. average
EDWARD C. ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329
253-858-0855/Fax 253-858-0856 elrobison@narrows.com
C.R. Laurence Glass Rail System (GRS) and Taper-Loc® 06/19/2014 Page 23 of 55
135S Surface Mounted Cont:
Maximum allowable wind loads'k" cap screws at 6" o.c. to structural steel develops full
strength of �fz" and W" glass:
M = 3,592#*[1.25"-0.5*3,592/(30ksi*6)] = 4,454"# = 371.18'# per anchor
36" height: w = 2*371.78#'/(0.55*32) = 150 psf
42" height: w = 2*371.78#'/(0.55*3.52) = 110.2 psf
For anchor into concrete:
3/8" diameter Screw -in anchor Hilti Kwik HUS-EZ (KH-EZ) s" x 4" manufactured by Hilti in
accordance with ESR-3027 or Hilti HSL-3 M8 x 3-3/4" anchor in accordance with ESR-1545.
Strength calculated in accordance with ACI 318-08 Appendix D. V,c : 3,000 psi
2-1/2" effective embedment nominal depth = 3-9/16" for KH-EZ and 3-5/16" for HSL-3
ONsa = 0.65*4,400# = 2,860#
For concrete breakout strength:
Ncb = [ANc/ANco]g1ed N(pc,N(pcp,NNb
ANc= (1.5*2.5"*2)*(1.5*2.5*2) = 56.25in2 Edge distance = 3 3/4"
ANc,= 9*2.52= 56.25in2
Ca,,;. = 1.5*2.5" = 3.75
Cac = 2.5*2.5" = 6.25
(Qed,N = 1.0
(Pc.N = 1.0 (from ESR-3027)
Q7cp,N=1.0 (from ESR-3027)
Nb = 24*1.0*✓3000*2.51S = 5,196#
Ncb = 56.25/56.25*1.0*1.0*1.0*5,196 = 5,196#
From ESR-3027 anchor pull out does not control design
ON, = 0.65*5,196# = 3,377#
Ns = ONn/1.6 = 3,377#/1.6 = 2,111#
Anchor steel strength will not control
Since shear load is under 0.2* shear strength interaction can be ignored; oV c >1.6*50/0.2= 400#
Moment resistance of each anchor:
For surface mounted
OM, = 3,377#*[1.25-0.5*3,377/(2*0.85*3ksi*12)] = 4,063"# = 338.54 per anchor
Ma = OMn/a, = 4,063"#/1.6 = 2,539"# = 211.58'#
(at 1' spacing doesn't develop full allowable glass load.)
Maximum allowable wind loads (ASD) for anchors at 12" o.c.:
36" height: w = 211.58#'/(0.55*32)= 42.7 psf
42" height: w = 211.58#'/(0.55*3.52)= 31.4 psf
EDWARD C. ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329
253-858-0855/Fax 253-858-0856 elrobison@narrows.com
C.R. Laurence Glass Rail System (GRS) and Taper-Loc@ 06/19/2014 Page 24 of 55
135S Surface Mounted Cont:
For 6" on center. spacing:
Minimum edge distance for 6" spacing is 3.75"
ANu= (6)*(1.5*2.5*2) = 45in2 Edee,distance = 3 3/V
Nib = 45/56.25* 1.0* 1.0* 1.0*5,196 = 4,157#
ONb = 0.65*4,157# = 2,702#
M = 0Nn/1.6 = 2,702#/1.6 = 1,689#
—-•------.loment-resistance for anchors af6 6n center:
0Mn = 2*2,702#*[1.25-0.5*2*2,702/(2*0.85*3ksi*12)] = 6,516"# = 543.03'#/ft
Ma = 9Mn/a, = 6,516"#/1.6 = 4,073"# = 339.4'#/ft
NOTE: When attached to concrete alternative anchors may be designed in accordance to the
anchor manufacturer's engineering reports that can develop greater strength.
Maximum allowable wind loads (ASD):
36" height: w = 339.4#'/(0.55*32)= 68.6 psf
42" height: w = 339.4#'/(0.55*3.52)= 50.4 psf
Determine minimum allowable edge distance for anchors at 1291on center:
Minimum acceptable edge distance is 2.35" For 42" guard height
ANC= (1.5*2.5"*2)*(1.5*2.5+2.35) = 45.75in2 Minimum edge distance is 2.35"
NO = 45.75/56.25*1.0*1.0*1.0*5,196 = 4,226#
ONn = 0.65*4,226# = 2,747#
M = 6Nn/1.6 = 2,747#/1,6=1,717#
OMn = 2,747#*[1.25-0.5*2,747/(2*0.85*3ksi* 12)] = 3,372"# = 2814 per anchor
Ma = 0Mn/a, = 3,372"#/1.6 = 2,108"# = 175.6 (at I'spacing doesn't develop full allowable glass
load.)
Maximum allowable wind loads (ASD):
36" height: w = 175.6#'/(0.55*32)= 35.5 psf
42" height: w = 175.6#'/(0.55*3.52)= 26.1 psf
Determine minimum allowable edge distance for anchors at Von center:
Minimum installation edge distance is 1.75" for the anchors
ANC= (6)*(1.5*2.5+1.75) = 33in2 Minimum ed a distance is 1.75"
N.b = 33.0/56.25*1.0*1.0*1.0*5,196 = 3,048#
ONa = 0.65*3,048# = 1,981#
Ns = ONn/1.6=1,981#/1.6 =1,238#
OM, = 2*1,981#*[1.25-0.5*2*1,981/(2*0.85*3ksi*12)] = 4,824"# = 4024 per anchor
Ma = OMn/),. = 4,824"#/1.6 = 3,015"# = 251.264 (at I'spacing doesn't develop full allowable
glass load.)
Maximum allowable wind loads (ASD):
36" height: w = 251.26#'/(0.55*32)= 50.8 psf
42" height: 'w = 251.26#'/(0.55*3.52)= 37.3 psf
EDWARD C.ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329
253-858-0855/Fax 253-858-0856 elrobison@narrows.com
C.R. Laurence Glass Rail System (GRS) and Taper-Loc® 06/19/2014 Page 25 of 55
B5S Fascia (Side) mounted base shoe:
Verify Anchor Pull through
For counter sunk screw
Pnov = (0.27+1.45t/D)DtFty
=(0.27+1.45*.5*/.5).5*.5*l6 ksi
Pnov = 6,880#
Pa = 6,880/3 = 2,293#
Aluminum strength controls
For inset bolt
Shear strength:
tmin = 0.25"
Pnov = Ftu/-%/3*(A,)
Av = 0.25"*rt*.75"=0.589 in2
Pnov = 30ksil✓3*(0.589 in2)= 10.2k
Dead Load
DL= 3.5'*9.5psf+10.4plf = 43.7p1f
Moment from dead load:
MD = 43.7plf*2.5/2 = 54.6"#/ft = 4.55'#/ft
Since shear load is under 0.2* shear strength (>2.7 k) interaction can be ignored.
For standard installation, 42" (46" above bottom of shoe) guard height and 50 plf top rail load
ML = 46"*50plf = 2,300"#
Moment resistance of single anchor:
Ma = 2,293*2" = 4,586"# = 382.17'#
Required anchor spacing = 4,586/2,300 = 1.994` use 2'
Maximum anchor spacing is 2' o.c. and within l' of rail end.
Maximum allowable wind loads (ASD) for %" cap screw at 12" o.c. spacing, into steel:
Mw = 382.17-4.55 = 377.62'#/ft
36" height: w = 377.62#'/(0.55*3.333*3.0)= 68.7 psf
42" height: w = 377.62#'/(0.55*3.5*3.833)= 51.2 psf
Maximum allowable wind loads (ASD) for %" cap screw at 6" o.c. spacing, into steel:
Mw = 2*382.17-4.55 = 759.79'#/ft
36" height: w = 759.79#'/(0.55*3.333*3.0)= 138.2 psf
42" height: w = 759.79#'/(0.55*3.5*3.833)=103.0 psf
EDWARD C. ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329
253-858-0855/Fax 253-858-0856 elrobison@narrows.com
C.R. Laurence Glass Rail System (GRS) and Taper-Loc® 06/19/2014 Page 26 of 55
B5S Fascia (Side) ri►ounted _base shoe cont:
For anchor into concrete:
3/8" diameter Screw -in anchor 13ilti Kwik HUS-EZ (KH-EZ) %" x 4" manufactured by Hilti in
accordance with ESR-3027 or Hilti HSL-3 M8 x 3-3/4" anchor in accordance with ESR=1545.
Strength calculated in accordance with ACI 318-08 Appendix D. f'c�: 3,000 psi
2-1/2" effective embedment C
ONsa = 0:65*4,400# = 2,860#
For concrete breakout -strength; -
Ncb = [ANc7ANcoltped,Nq)c,N(Qcp)NNb
ANc= (1.5*2.5"*2)*(1.5*2.5+2.06") = 43.575in2 Minimum edge distance = 2.06"
ANco= 9*2.52 = 56.25in2
Ca,min = 1.5*2.5" = 3.75
Cac=2.5*2.5" = 6.25
tped,N = 1.0
rQc,N = 1.0 (from ESR-3027)
cpcp,N= 1.0 (from ESR-3027)
Nb = 24*1.0*✓3000*2.51S = 5,196#
Ncb = 43.575/56.25*1.0*1.0*1.0*5,196 = 4,025#
From ESR-2526 anchor pull out does not control design
ON. = 0.65*4,025# = 2,616#
Ns = ONn/1.6 = 2,616#/1.6=1,635#
Anchor steel strength will not control
Moment resistance of each anchor:
For Fascia mounted
OMn = 2,616#*[2.06-0.5*2,616/(2*0.85*3ksi* 12)] = 5,333"# = 444.42'# per anchor
Ma = OM.& = 5,333"#/1.6 = 3,333"# = 277.76'# (at I'spacing)
Maximum allowable wind loads (ASD) for 12" o.c. anchor spacing, into steel:
Mw = 277.76-4.55 = 273.21'#/ft
36" height: w = 273.21#'/(0.55*3.333*3.0)= 49.7 psf
42" height: w = 273.21#'/(0.55*3.833*3.5) = 37.0 psf
For 6" on center spacing:
Minimum edge distance for 6" spacing is 3.75"
ANc= (6)*(1.5*2.5+2.06) = 34.86in2 Edge distance = 2.06"
Ncb = 34.86/56.25*1.0*1.0*1.0*5,196 = 3,220#
ON. = 0.65*3220# = 2,093#'
Ns = ¢Na/1.6 = 2,093#/1.6 = 1,308#
Moment resistance for anchors at 6" on center:
OM. = 2*2,093#*[2.0-0.5*2*2,093/(2*0.85*3ksi*12)] = 8,229"# = 685.74'#/ft
EDWARD C. ROBISON, PE, SE
10012 Crevistonbr NW
Gig Harbor, WA 98329
253-858-0855/Fax 253-858-0856 elrobison@narrows.com
C.R. Laurence Glass Rail System (GRS) and Taper-Loc® 06/19/2014
Page 27 of 55
135S Fascia (Side) mounted base shoe cont:
Ma = OMA = 8,229"#/1.6 = 5,143"# = 428.59'#/ft
Maximum allowable wind loads for anchors at 6" o.c.:
Mw = 428.59-4.55 = 424.04'#/ft
36" height: w'= 42404#'/(0.55*3.333*3.0)= 77.1 psf
42" height: w = 424.04#'/(0.55*3.833*3.5) = 57.5 psf
Fascia (Side) mounted 135S base shoe_towood: - - -
For Lag screws into solid wood (DFL, Southern Pine or equivalent density Ga0.49):
1/2" Lag screws strength in per National Design Specification for Wood Construction:
Required withdrawal strength for 50 plf live load on 42" rail:
T = 50plf*46"/2.06" = 1,117#/ft
T' = 2,300"#/(2.06-0.5*1,117/(12*625psi) = 1,158# (for wood bearing)
W = 367 pli embedment From NDS Table 11.2A
For dry or interior applications, Cm = 1.0, CD = 1.33
e = 1,158#/(367*1.33) = 2.37". Use 1/2" x 4" lag screws
For exterior wet applications, Cm = 0.7 applies when moisture content of wood may exceed
19%, CD = 1.33
e = 1,158#/(367*1.33*0.70) = 3.39" Use 1/2" x 4" lag screws
4" screw embed depth = 4"-0.25"-0.3125 = 3.4375
Moment Strength For lags at 12" on center:
For dry conditions:
Ti = 3.4375*367*1.33 = 1,678#
Mia = 1,678*(2.06-0.5*1,678/(12*625psi) = 3,269"#/ft = 272.41'#
Mw=272.41-4.55 = 267.86'#/ft
36".height: w = 267.86#'/(0.55*3.333*3.0)= 48.7 psf
42" height: w = 267.86#'/(0.55*3.833*3.5) = 36.3 psf
For wet conditions:
To = 3A375*367*1.33*0.7 = 1,175#
Moa = 1,175*(2.06-0.5*1,175/(12*625psi) = 2,328"#/ft = 194.04'#
Mw=194.04-4.55=189.49'#/ft
36" height: w = 189A9#'/(0.55*3.333*3.0)= 34.5 psf
42" height: w = 189.49#'/(0.55*3.833*3.5) =25.7 psf
Moment Strength For lags at 6" on center:
For dry conditions:
2*Ti = 2*1,678# = 3,356#
n' W" = 3,356*(2.06-0.5*3,356/(12*625psi) = 6,163"#/ft = 513.54'#
Mw - 513.54-4.55 = 508.99'#/ft
36" height: w = 508.99#'/(0.55*3.333*3.0)= 92.6 psf
42" height: w = 508.99#'/(0.55*3.833*3.5) = 69.0 psf
For wet conditions:
2*Ti = 2*1,175# = 2,350#
Moab' = 2,350*(2.06-0.5*2,350/(12*625psi) = 4,473"#/ft = 372.74'#
Mw = 372.74-4.55 = 368.19'#/ft
36" height: w = 368.19#'/(0.55*3.333*3.0)= 66.9 psf
42" height: w = 368.19#'/(0.55*3.833*3.5) = 49.9 psf
EDWARD C. ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329
253-858-0855/Fax 253-858-0856 ehobison@narrows.com
C.R. Laurence Glass Rail System (GRS) and Taper-Loc@ 06/19/2014 Page 28 of 55
B5L Low Profile Base Shoe
6063-T52 Aluminum extrusion
Fully tempered glass glazed in place with wet glazing
cement. Channel depth is inadequate to accommodate
the Taper-Loc® system fully within the base shoe.
Shoe strength — Vertical legs:
Glass reaction by bearing on legs to form couple.
Allowable moment on legs:
Ma=SiF,
Fy = 12.5 ksi (ADM Table 2-23, Sec 3.4.4 and 3.4.13)
Si = 12"*0.625"2*/6 = 0.78125 in3/ft
Ma = 12.5 ksi*0.78125 in3/ft = 9,766#"/ft
Leg shear strength @ base
tmin = 0.625"
Fv= 5.5 ksi (ADM Table 2-23, Sec 3.4.20
Vaii = 0.625"*12"/ft*5.5 ksi = 41.25 k/ft
For 1/2" cap screw to tapped steel, CRL Screw part
SHCS 12x34 or SHCS 12x1
Tn = Asa*tc*0.6*F,u
where tc = 0.25"; Asa = 1.107" and Ft, = 58 ksi (A36 steel plate)
Tn=1.107"*0.25*0.6*58 ksi = 9.63 k
Bolt tension strength = 0.75*67.5 ksi*0.1419 inz = 7.18 k
Since shear load is under 0.2* shear strength (Va = 2.7k) interaction can be ignored.
Use 5/16" minimum for maximum load:
Maximum service load: 7.18k/2 = 3,592#
Maximum allowable moment for 12" on center spacing and direct bearing of base shoe on steel:
M = 3,592#*[1.125"-0.5*3,592/(30ksi*12)] = 4,023"# = 335.26'# per anchor
�-21 /4'
Maximum allowable wind loads (ASD)1h" cap screws at 12" o.c. to structural steel:
36" height: w = 335.26#'/(0.55*32) = 67.7 psf
42" height: w = 335.26#'/(0.55*3.52) = 49.8 psf
To develop the full strength of W" or %a" glass anchor spacing must be decreased to an average
spacing of:
W" glass: 67.7/71.1*12=11.43" o.c.
%" glass: 67.7/114.4* 12 = 7.10" o.c.
Maximum allowable wind loads (ASD) %" cap screws at 6" o.c. to structural steel:
36" height: w = 2*333#'/(0.55*32) =134.5 psf
42" height: w = 2*333#'/(0.55*3.52) = 98.8 psf
EDWARD C. ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329
253-858-0855/Fax 253-858-0856 elrobison@narrows.com
C.R. Laurence Glass Rail System (GRS) and Taper-Loc® 06/19/2014
Page 29 of 55
B5L Surface Mounted Continued:
For anchor into concrete:
3/8" diameter Screw -in anchor Hilti Kwik HUS-EZ (KH-EZ) %" x 4" manufactured by Hilti in
accordance with ESR-3027 or Hilti HSL-3 M8 x 3-3/4" anchor in accordance with ESR-1545.
Strength calculated in accordance with ACI 318-08 Appendix D.
f'cZ 3,000 psi
2-1/2" effective embedment
For -concrete -breakout strength:
NO = [AN-/ANco1(r1edN(pc,N(Pcp,NNb
Am= (1.5*2.5"*2)*(1.5*2.5*2) = 56.25in2 Edge distance = 3 3/4"
ANco= 9*2.52 = 56.25in2
Ca,min = 1.5*2.5" = 3.75
Cae = 2.5*2.5" = 6.25
(pedN =1.0
(Pc,N = 1.0 (from ESR-3027)
q)cp,N=1.0 (from ESR-3027)
Nb = 24*1.0'A000*2.51s = 5,196#
Ncb = 56.25/56.25*1.0*1.0*1.0*5,196 = 5,196#
From ESR-3027 anchor pull out does not control design
On = 0.65*5,196# = 3,377#
Ns = 0Na/1.6 = 3,377#/1.6 = 2,111#
Anchor steel strength will not control
Moment resistance of each anchor:
For surface mounted
OMn = 3,377#*[1.125-0.5*3,377/(2*0.85*3ksi*12)] = 3,705"# = 308.8'# per anchor
Ma = OMa/),. = 3,705"#/1.6 = 2,31511# = 193.0'# (at I'spacing doesn't develop full allowable
glass load for 1/2" glass.)
Maximum allowable wind loads (ASD):
36" height: w = 193.0#'/(0.55*32)= 39.0 psf
42" height: w = 193.0#'/(0.55*3.52)= 28.6 psf
Minimum acceptable edge distance for 50plf live load
Axe= 2100/2315*56.2 = 50.98
bac = 50.98/(1.5*2.5"*2) - (1.5*2.5) = 3.047" Minimum edge distance is 3 047"
Neb = 50.98/56.25*1.0*1.0*1.0*5,196 = 4,709#
ONn = 0.65*4,709# = 3,061#
M = ON /1.6 = 3,061#/1.6=1,913#
OMn = 3,061#*[1.125-0.5*3,061/(2*0.85*3ksi*12)] = 3,367"# = 280.59'# per anchor
Ma = 0Ma/X = 3,367"#/1.6 = 2,104"# = 175.37'# (at I'spacing doesn't develop full allowable
glass load.)
EDWARD C. ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329
253-858-0855/Fax 253-858-0856 elrobison@bnarrows.com
C.R. Laurence Glass Rail System (GRS) and Taper-Loc@ 06/19/2014 Page 30 of 55
B5L Surface Mounted Continued:
Maximum height for 50 plf live load for 12" o.c. anchors at 3.047" edge distance:
Hxn x5o = 2,104"#/50 = 42.08"
Maximum allowable wind loads (ASD) at 3.047" edge distance, 12" on center:
36" height: w=175.37#'/(0.55*32) = 35.4 psf
42" height: w = 175.37#/(0.55*3.52) = 26.0 psf
For 6" on center spacing:
ANC= (6)*(1.5*2.5*2) = 45in2 Edge distance = 3 3/4"
NCb = 45/56.25*1.0*1.0*1.0*5,196 = 4,157#
ONn = 0.65*4,157# = 2,702#
Ns = ONa/1.6 = 2,702#/1.6=1,689#
Moment resistance for anchors at 6" on center:
OM. = 2*2,702#*[1.125-0.5*2*2,702/(2*0.85*3ksi*12)] = 5,841"# = 486.74'#/ft
Ma = WMn/a. = 5,841"#/1.6 = 3,651"# = 304.21'#/ft
NOTE: When attached to concrete alternative anchors may be designed in accordance to the
anchor manufacturer's engineering reports that can develop greater strength.
Maximum allowable wind loads (ASD) for anchors at 6" o.c.:
36" height: w = 304.21#'/(0.55*32)= 61.5 psf
42" height: w = 304.21#'/(0.55*3.52)= 45.2 psf
Minimum edge distance for 6" on center anchors:
ANng= (6)*(1.5*2.5+1.75) = 33in2 Minimum allowable edge distance is 175"
Nib = 33/56.25*1.0*1.0*1.0*5,196 = 3,048#
ONn = 0.65*3,048# = 1,981#
Ns = ONn/1.6 = 1,981#/1.6=1,238#
4Mn = 2*1,981#*[1.125-0.5*2*1,981/(2*0.85*3ksi*12)] = 4,329"# = 360.75'#
Ma = 0Mn/),, = 4,329"#/1.6='2,706"# = 225.47'# (at I'spacing doesn't develop full allowable
glass load.)
Maximum allowable wind loads (ASD) for anchors at 6" o.c. 1.75" edge distance:
36" height: w = 225.47#'/(0.55*32)= 45.6 psf
42" height: w = 225.47#'/(0.55*3.52)= 33.5 psf
EDWARD C. ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329
253-858-0855/Fax 253-858-0856 elrobison@narrows.com
C.R. Laurence Glass Rail System (GRS) and Taper-Loc® 06/19/2014 Page 31 of 55
B5L FASCIA (SIDE) MOUNTED BASE SHOE
For side mounted base shoe the allowable loads are:
Screw into steel:
Dead Load
DL= 3.5' *9.5psf+10.4plf = 43.7plf
Moment from dead load:
MD = 43.7p1f*2.25/2 = 49.2"#/ft = 4.1'#/ft
1/2" Countersunk screw
bin = 0.409"
P.w = FeJI✓3*(Av)
Av = 0.409"*7u*.75"=0.964 in2
P. = 30ksi/✓3*(0.964 inz)= 16.69k
screw strength will control
Ta=10.8/3 = 3.6k ASTM F 879 Cond CW Screw
Ma = 3.6k*[1.75"-0.5*3.6k/(30ksi*12)]
Ma = 6,282#" = 523.5#' per anchor
Mw = 523.5-4.1 = 519.4'#/ft
Maximum allowable wind loads (ASD):
36" height: w = 519.49'/(0.55*3'*3.292) = 95.6 psf
42" height: w = 519.4#'/(0.55*3.5*3.792) = 71.2 psf
1/2" Cap screw
bin = 0.132
A� = 0.132"*rt*.75"= 0.311 inz
Pao = 30ksi/-V3*(0.311in2)= 5.4k
base shoe tear through will control
Pa = 5.4/3 = 1.8k
Ma =1.8k*[1.75"-0.5*1.8k/(30ksi*l2)]
Ma = 3,145.5#" = 262.1#' per anchor
Mw = 262.1-4.1 = 258.0'#/ft
Maximum allowable wind loads (ASD) for cap screws at 12"o.c.:
36" height: w = 258.0#'/(0.55*3' *3.292) = 47.5 psf
42" height: w = 258.0#'/(0.55*3.5*3.792) = 35.3 psf
Maximum allowable wind loads for cap screws at 611o.c.:
Ma = 2*1.8k*[1.75"-0.5*2*1.8k/(30ksi*12)]
Ma = 6,282#" = 523.5#' per anchor
Mw = 523.5-4.1 = 519.4'#/ft
36" height: w = 519.4#'/(0.55*3'*3.292) = 95.6 psf
42" height: w = 519.4#'/(0.55*3.5*3.792) = 71.2 psf
EDWARD C. ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329
253-858-0855/Fax 253-858-0856 elrobison@narrows.com
C.R. Laurence Glass Rail System (GRS) and Taper-Loc® 06/19/2014 Page 32 of 55
B5L Fascia Mounted Continued:
For anchor into concrete:
3/8" diameter Screw -in anchor Hilti Kwik HUS-EZ (KH-EZ) %"
x 4" manufactured by Hilti in accordance with ESR-3027 or Hilti
HSL-3 M8 x 3-3/4" anchor in accordance with ESR-1545.
Strength calculated in accordance with ACI 318-08 Appendix D.
f'c >_ 3,000 psi
2-1/2" effective embedment
OMa = 0.65*4,400# = 2,860#
For concrete breakout strength:
Ncb = 1ANc/ANc01(Ped,NC)c,N(Pcp,NNb
ANc= (1.5*2.5"*2)*(1.5*2.5+1.75") = 41.25in2 Minimum Edge
distance is 1.75"
ANco= 9*2.52 = 56.25in2
Ca,min = 1.5*2.5" = 3.75
Cac=2.5*2.5"=6.25
111ed.N = 1.0
(1c,N = 1.0 (from ESR-3027)
q)cp,N= 1.0 (from ESR-3027) '
Nb = 24*1.0*✓3000*2.515 = 5,196#
Ncb = 41.25/56.25*1 .0*1 .0* 1 .0*5,196 = 3,810#
From ESR-3027 anchor pull out does not control design
ON, = 0.65*3,810# = 2,577#
Ns = ONn/1.6 = 2,577#/1.6 = 1,548#
Anchor steel strength will not control
Moment resistance of each anchor:
For Fascia mounted
OM. = 2,577#*[1.75-0.5*2,577/(2*0.85*3ksi*12)1 = 4,455"# = 371.29'# per anchor
Ma = OM./a, = 4,455"#/1.6 = 2,78511# = 232.06'#
Mw = 232.06-4.1 = 227.96'#/ft
Maximum allowable wind loads (ASD) for cap screws at 12"o.c.:
36" height: w = 227.96#'/(0.55*3'*3.292) = 42.0 psf
42" height: w = 227.96#'/(0.55*3.5*3.792) = 31.2 psf
For 6" on center anchors:
ANcg= (6)*(1.5*2.5+1.75) = 33in2 Minimum allowable edge distance is 1 75"
Ncb = 33/56.25*1.0*1.0*1.0*5,196 = 3,048#
ON. = 0.65*3,048#= 1,981#
Ns = ONn/1.6 = 1,981#/1.6=1,238#
OMn = 2*1,981#*[1.75-0.5*2*1,981/(2*0.85*3ksi*12)1= 5,395"# = 449.54'#
Ma = OMn/a. = 5,395"#/1.6 = 3,372"# = 280.99'#
Mw = 280.99-4.1 = 276.89'#/ft
Maximum allowable wind loads (ASD) for anchors at 6" o.c. 1.75" edge distance:
36" height: w = 276.89#'/(0.55*3*3.292)= 51.0 psf
42" height: w = 276.89#'/(0.55*3.5*3.792)= 37.9 psf
EDWARD C. ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329
253-858-0855/Fax 253-858-0856 elrobison@narrows.com
C.R. Laurence Glass Rail System (GRS) and Taper-Loc@ 06/19/2014
Page 33 of 55
B5L Fascia Mounted Continued:
Fascia (Side) mounted B5L base shoe to wood:
For Lag screws into solid wood (DFL Southern Pine or equivalent density G>_0.49)•
1/2" Lag screws strength in per National Design Specification for Wood Construction:
W = 367 pli embedment From NDS Table 11.2A
For dry or interior applications, Cm = 1.0, CD = 1.33
e = 1,158#/(367*1.33) = 2.37" Use 1/2" x 4" lag screws
For exterior wet applications, Cm = 0.7 applies when moisture content of wood may exceed
19%, CD = 1.33
e = 1,158#/(367*1.33*0.70) = 3.39" Use 1/2" x 4" lag screws
4" screw embed depth = 4"-0.25"-0.3125 = 3.4375
Moment from toprail load about bottom of base shoe:
M36 = 50plf*(36+3.75) = 1,987.5"#/ft = 190.625'#/ft
M42 = 50plf*(42+3.75) = 2,287.5"#/ft = 190.625'#/ft
Moment Strength For lags at 12" on center:
For dry conditions:
Ti = 3.4375*367*1.33 = 1,678#
Mi. =1,678*(1.75-0.5*1,678/(12*625psi) = 2,749"#/ft = 229.07'#
Mw = 229.07-4.1 = 224.97'#/ft
36" height: w = 224.97#'/(0.55*3.292*3.0)= 41.4 psf
42" height: w = 224.97#'/(0.55*3.792*3.5) = 30.8 psf
For wet conditions:
To = 3.4375*367*1.33*0.7 = 1,175#
Moa= 1,175*(1.75-0.5*1,175/(12*625psi) = 1,964"#/ft = 163.68'#
Mw = 163.68-4.1 = 159.58'#/ft
MAY ONLY BE USED FOR PRIVATE RESIDENCES WITH 6' MINIMUM LENGTH
NOT ALLOWED FOR USES 36" height: w = 159.58#'/(0.55 OTHER THAN PRIVATE RESIDENCES
*3.292*3.0)= 29.4 psf
42" height: w = 159.58#'/(0.55*3.792*3.5)= 21.9 psf
Moment Strength For lags at 6" on center:
For dry conditions:
2*Ti = 2*1,678# = 3,356#
Mia6" = 3,356*(1.75-0.5*3,356/(12*625psi) = 5,122"#/ft = 426.85'#
Mw = 426.85-4.1 = 422.75'#/ft
36" height: w = 422.75#'/(0.55*3.292*3.0)= 77.8 psf
42" height: w = 422.75#'/(0.55*3.792*3.5)= 57.9 psf
For wet conditions:
2*Ti = 2*1,175#=2,350#
Moab' = 2,350*(1.75-0.5*2,350/(12*625psi) = 3,744"#/ft = 312.03'#
Mw = 312.03-4.1 = 307.93'#/ft
36" height: w = 307.93#'/(0.55*3.292*3.0)= 56.8 psf
42" height: w = 307.93#'/(0.55*3.792*3.5) = 42.2 psf
EDWARD C. ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329
253-858-0855/Fax 253-858-0856 elrobison@narrows.com
C.R. Laurence Glass Rail System (GRS) and Taper-Loc® 06/19/2014
B5T Tapered Base Shoe
6063-T52 Aluminum
Shoe strength — Vertical legs:
Glass reaction by bearing on legs to form couple.
Allowable moment on legs:
Ma=S1Fy
Fy = 12.5 ksi (ADM Table 2-24, Sec 3.4.4)
Si = 127N..5'12% = 0.5 in3/ft
Ma = 12.5 ksi*0.5 in3/ft = 6250"#/ft
Leg shear strength @ base
tm;o = .5
K= 5.5 ksi (ADM Table 2-23, Sec 3A.20
Vau = 0.5"*12"/ft*5.5 ksi = 33 k/ft
Can be anchored down same as the standard 2-1/2" base
shoe B5S. The anchorage will have the same strength and
loading characteristics.
Embedded Base Shoe Option (All base shoe types can be
used)
Calculation based on base shoe embedded without any
attachment to reinforcing or otherwise anchored.
Reaction on concrete:
Compression on top edge:
0.85*f'c*a = M/(h-a/2)
Solve for a
1/2a2-0.85f'cha — M = 0
M = 10,000#"/ft, h = 4.125", f'c = 2,500 psi
1/2a2-0.85*2,500*4.125a — 10,000 = 0
1/2a2-8765.625a—10,000 = 0
using the quadratic equation to solve for a:
[8765.625+/-✓(8765.6252+4*0.5*10000)1/(2*0.5) = 1.14"
1.14" < 1/3*4.125" therefore okay.
Embedded base shoe will safely support 10,000"#/ft of moment
There is no fascia mounted option for the B5T base shoe.
EDWARD C. ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329
253-858-0855/Fax 253-858-0856 elrobison@narrows.com
Page 34 of 55
C.R. Laurence Glass Rail System (GRS) and Taper-Loc@
06/19/2014 Page 35 of 55
B5A SurfaceMate Square Base Shoe 2-1/2" x 4-1/4"
B5A Shoe is designed to be interchangeable with the B5S
Shoe. The B5A base shoe allowable loads are the
1"
same as
for the B5S shoes for all anchor types and configurations.
(25.4 mm)
Refer to the B5S base shoe calculations for allowable
loads and supporting calculations for the anchor type.
SurfaceMate Angle Adjust Curved Blocks
4-1/40 -
Used at each anchor bolt to allow adjustment of the B5A
.106.4 mm)
base shoe to plumb on an out of level or uneven substrate.
When used on a steel substrate anchors and allowable
j
loads are the same as for the B5S.
2-11T
(63.5 mm)
When installed on a concrete substrate grout shall be
packed solid under the base shoe or a continuous shim
strip used in order to develop the full allowable loads as
-
calculated for the B5S.
Aluminum
-. Angle Adjust
When installed on concrete substrate without grouting or
Curved Block
continuous shim the allowable loads are adjusted to:
For 3-3/4" anchor edge distance_
Aluminum
Ma = 2,111#*[1.25-0.5*2,111/(2*0.85*3ksi*2.25)] _
-r" Horseshoe
Shim
2,445"# = 203.7'# per anchor
Maximum allowable wind loads (ASD) for 12" spacing:
36" height: w = 203.7'#/(0.55*32) = 41.2 psf
42" height: w = 203.7'#/(0.55*3.52) = 33.1 psf
For minimum edge distance is 2.35"
OM. = 1,717#*[1.25-0.5*l,717/(2*0.85*3ksi*2.25)] = 2,018"# = 168.2'# per anchor
Anchor spacing must be decreased for 42" guard height when 50 ulf live load applies
S50-42 = 2,018 #/ft/(50*42 )*12 = 11 5" o c (use 11 anchors for 10 section)
Maximum allowable wind loads (ASD) (12" o.c. spacing):
36" height: w = 168.2#'/(0.55*32) = 34.0 psf
42" height: w = 168.2#'/(0.55*3.52) = 25.0 psf (DOESN'T MEET 50PLF LIVE LOAD)
B5A Surface Mounted to Concrete Continued:
EDWARD C. ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329
253-858-0855/Fax 253-858-0856 ekobison@narrows.com
C.R. Laurence Glass Rail System (GRS) and Taper-Loc® 06/19/2014 Page 36 of 55
For concrete anchors at 6" on center:
Refer to 135S for anchor strength calculations.
For 3 3/a" minimum edge distance
0Mo= 1,689#*[1.25-0.5* l,689/(2*0.85*3ksi*2.25)] = 1,987"# = 165.58'# per anchor
Maximum allowable wind loads (ASD) (6" o.c. spacing):
36" height: w = 2*165.58#'/(0.55*32) = 66.9 psf
42" height: w = 2* 165.58#'/(0.55*3.52) = 49.2 psf
For 13/a" minimum edge distance
0Mo = 1,238#*[1.25-0.5*1,238/(2*0.85*3ksi*2.25)] = 1,481"4 = 123.39'# per anchor
Maximum allowable wind loads (ASD) (6" o.c. spacing):
36" height: w = 2*l23.39#'/(0.55*32) = 49.9 psf
42" height: w = 2*123.39#'/(0.55*3.52) = 36.6 psf
Not to be surface mounted directly to wood substrates
Fascia mount is same as for B5S
EDWARD C. ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329
253-858-0855/Fax 253-858-0856 elrobison@narrows.com
C.R. Laurence Glass Rail System (GRS) and Taper-Loc® 06/19/2014
B5G - Green Base Shoe
6063-T52 Aluminum extrusion
Shoe strength — Vertical legs:
Glass reaction by bearing on legs to form couple. Allowable
moment on legs:
Ma = Si*Ft or Fe
Ft = Fe = 12.5 ksi (ADM Table 2-23, Sec 3.4.4 and 3.4.13)
At top 2ad cell
Smid = 12"*0.275"2*/6 = 0.151 in3/ft
Ma =12.5 ksi*0.151 in3/ft = 1,891#"/ft 4
Pa = 1,891"#/1.38" = 1,370 plf
At mid -height
Smid = 12"*0.346" 2*/6 = 0.239 in3/ft
Ma = 12.5 ksi*0.239 in3/ft = 2,993#"/ft
Pa = 2,993"#/2.24" = 1,336 Of
At bottom cell:
Smid = 12"*0.405" 2*/6 = 0.328 in3/ft
Ma = 12.5 ksi*0.328 in3/ft = 4,100#"/ft
Pa = 4,100"#/2.83" = 1,449 plf
Maximum allowable glass moment based on base shoe leg strength:
Ma = 1,336plf*2.875" = 3,841"#/ft
Check leg deflection for 3,800"#/ft moment on rail:
p = 3,800/(2.875") = 1,322plf
Ieff = [(0.440)3+(0.355)3 +(0.300) 3 +(0.275) 3]/4 = 0.0444 in4/ft
A = Ph3/(3EI)=1,322*2.8753/(3*10.1x106*0.0444) = 0.0233"
Deflection at top:
Atop = 42/2.875*0.0233 = 0.34"
Leg shear strength @ groove
tmin = 0.275"
Fv= 5.5 ksi (ADM Table 2-23, Sec 3.4.20)
Vau = 0.275"* 12"/ft*5.5 ksi =18.15 k/ft
Compression strength of ribs:
Fe = 8.9-0.037(kL/r) = 8.9-0.037(2*0.475/(0.125/✓12) = 7.926 ksi
Pc = 7,926psi*12"*0.125"=11,889 plf z 1,322 plf rib strength is adequate
Attachment is same as for B5S base shoe for all uses.
EDWARD C. ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329
253-858-0855/Fax 253-858-0856 elrobison@narrows.com
Page 37 of 55
C.R. Laurence Glass Rail System (GRS) and Taper-Loc@ 06/19/2014
8B Series - Square, Cored Base Shoe
6063-T52 Aluminum extrusion
Shoe strength — Vertical legs:
Glass reaction by bearing on legs to form couple. Allowable
moment on legs:
Ma = Si*Ft or F.
Ff= FE- = 12:5-ksi (ADM Table 2-23, Sec 3.4.4 and 3A.13)
4.
At 3rd cell - Rectangular cell used for fascia mounted
option.
Moment resistance across cell
Ma = Ai*Ta*c = 0.14"*12.5ksi*(0.75-0.14)
Ai = area of inside leg
Ma = 1.0675k"/" = 12,810"#/ft
Page 38 of 55
.130
a/// n 75
3
.250.
.140
u D
4V
Allowable shear across cell - based on shear bending across cell legs allowing rotation at top
Va = (Si+So)*Ta/b
S;, So = section modulus of inside or outside leg
b = height of cell = 0.915"
Va =(0.142/6+0.252/6)*12.5ksi/0.915"
Va = 187#/in = 2,243 plf (won't control)
Strength at bottom cell - truss action around cell -
Ma = Av*Ta*c = 0.14"*12.5ksi*(0.75-0.14) = 12,810"#/ft
Av = area of vertical leg, Ad = Area of diagonal load
Allowable shear across cell:
Va = Ad*Ta
Va = (0.14*12.5ksi) = 1,750pli = 21,000 plf (shear won't control)
Maximum allowable glass shear load reaction on top of base shoe, based on base shoe leg
strength:
Va = Ma/B = 12,810"#/ft/3.313" = 3,866 plf
Check leg deflection for 3 (800"#/ft moment on rail:
Strain in cell walls:
E _ ((Y/E)*B = [(3,800/(0.14"*12"*0.61")/10,100,000]*3.313" = 0.0012"
Ae = (2*0.0012")/(0.75/2) = 0.0065"
Ab = 3800*3.3132/(3*10,100,000*0.753) = 0.0033"
AT = Ae + Ab = 0.0065+0.0033 = 0.0098"
Glass deflection at 42" above base shoe from ase shoe leg deflection
Ag = 0.0098*(42/3.313) = 0.124" based on 3,800"# glass moment; 0.069" for typical 50 plf LL.
Attachment is same as for B5S base shoe for all uses.
EDWARD C. ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329
253-858-0855/Fax 253-858-0856 elrobison@narrows.com
C.R. Laurence Glass Rail System (GRS) and Taper-Loc® 06/19/2014
Page 39 of 55
B6S 2 5/8" X 41/8" GLASS BALUSTRADE BASE SHOE
Heavy Duty Square Base Shoe
6063-T52 Aluminum extrusion 2-5/8'
Fully tempered glass glazed in place, either wet (66.7 mm)
�
glazing cement or Taper-Loc®.
Shoe strength — Vertical legs: 1 4-1/80
Glass -reaction by bearing on legs to form (104.8 mm)
couple. Allowable moment on legs: 7/8" (22.2 mm)
Ma=SiFy
F, = Fc = 12.5 ksi (ADM Table 2-23, Sec 3.4.4 1/2" (12.7 mm) 13/16'
and 3.4.13) (20.6 mm)
Si = 12"*0.75"2*/6 = 1.125 in3/ft (�[
Ma = 12.5 ksi*1.125 in3/ft = 14,062#"/ft 9/16' (14.3 mm)
Leg shear strength @ groove
train = 0.343"
Fv= 5.5 ksi (ADM Table 2-23, Sec 3.4.20
Vau = 0.75"* 12"/ft*5.5 ksi = 49.5 k/ft
Base shoe anchorage:
Typical rail section: 42" high 50 plf top rail load or 25 psf panel load
Mt = 50plf*42" = 2,100"#/ft
Mw = 25 psf*3.5'*21"=1,837.5"#
Typical Anchor load — 12" O.C. — Ta = 2,100"#/1.3 1 " = 1,603#
Maximum allowable moment for 1/2" cap screws (Ta = 3,592# from B5S calculations)12" on
center spacing and direct bearing of base shoe on steel:
Ma = 3,592#*[1.31"-0.5*3,592/(30ksi*12)] = 4,688"# = 390.6'# per anchor
Maximum allowable wind loads (ASD):
36" height: w = 390.6#'/(0.55*32)= 78.9 psf
42" height: w = 390.6#'/(0.55*3.52)= 58.0 psf
6" on center spacing and direct bearing of base shoe on steel:
Ma = 3,592#*[1.31 "-0.5*3,592/(30ksi*6)] = 4,670"# = 389.14'# per anchor
Maximum allowable wind loads (ASD):
36" height: w = 2*389.14#'/(0.55*32)= 157.2 psf
42" height: w = 2*389.14#'/(0.55*3.52)= 115.5 psf
required spacing to develop full strength of %" glass:
s = 4,688/6,797* 12" = 8 /a" on center average
EDWARD C. ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329
253-858-0855/Fax 253-858-0856 elrobison@narrows.com
C.R. Laurence Glass Rail System (GRS) and Taper-Loc® 06/19/2014 Page 40 of 55
B6S Surface Mounted to Concrete:
For anchor into concrete:
3/8" diameter Screw -in anchor Hilti Kwik HUS-EZ (KH-EZ) %" x 4" manufactured by Hilti in
accordance with ESR-3027 or Hilti HSL-3 M8 x 3-3/4" anchor in accordance with ESR-1545.
Strength calculated in accordance with ACI 318-08 Appendix D.
2-1/2" effective embedment
Minimum concrete strength: V. z 3,000 psi
ONsa=.0.65*4,400#= 2,860#
For concrete breakout strength:
Ncb = [ANc/ANco]tped,Ntpc>Ntpbp,NNb
ANc= (1.5*2.5"*2)*(1.5*2.5*2) = 56.25in2 Edge distance = 3 3/4"
ANeo= 9*2.52 = 56.25in2
Camin = 1.5*2.5" = 3.75
Cac = 2.5*2.5" = 6.25
(ped,N = 1.0
1pe,N = 1.0 (from ESR-3027)
cpcp,N= 1.0 (from ESR-3027)
Nb = 24*1.0*✓3000*2.51s = 5,196#
Ncb = 56.25/56.25* 1.0* 1.0* 1.0*5,196 = 5,196#
From ESR-2526 anchor pull out does not control design
ON. = 0.65*5,196# = 3,377#
Ns = ONn/1.6 = 3,377#/1.6 = 2,111#
Anchor steel strength will not control
Moment resistance of each anchor:
For surface mounted
OM. = 3,377#*[1.31-0.5*3,377/(2*0.85*3ksi*12)] = 4,331"# = 360.9'# per anchor
M. = OMA = 4,331"#/1.6 = 2,707"# = 225.58'# (at 1' spacing doesn't develop full allowable
glass load for 5/8" glass.)
Maximum allowable wind loads (ASD) for 12" o.c, anchors:
36" height: w = 225.58#'/(0.55*32) = 45.6 psf
42" height: w = 225.58#'/(0.55*3.52) = 33.5 psf
Minimum acceptable edge distance is 2.35" For 42" guard height and 12" o.c. spacing.
ANc= (1.5*2.5"*2)*(1.5*2.5+2.35) = 45.75in2 Minimum edge distance is 235"
Ncb = 45.75/56.25*1.0*1.0*1.0*5,196 = 4,226#
ONn = 0.65*4,226# = 2,747#
Ns = ONn/1.6 = 2,747#/1.6=1,717#
OMn = 2,747#*[1.31-0.5*2,747/(2*0.85*3ksi*12)] = 3,537"# = 294.7'# per anchor
Ma = OMn/a. = 3,537"#/1.6 = 2,211"# = 184.2'# (at I'spacing doesn't develop full allowable
glass load.)
EDWARD C. ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329
253-858-0855/Fax 253-858-0856 eh'obison@narrows.com
C.R. Laurence Glass Rail System (GRS) and Taper-Loc@ 06/19/2014 Page 41 of 55
B6S Surface Mounted to Concrete continued:
Maximum allowable wind loads (ASD):
36" height: w = 184.2#'/(0.55*32) = 37.2 psf
42" height: w = 184.2#'/(0.55*3.52) = 27.3 psf
6" O.C. Anchor Spacing, 3.75" edge spacing:
ANc= (6)*(1.5*2.5*2) = 45in2 Edge distance = 3 3/4"
Nib = 45/56.25*1.0*1.0*1.0*5,196 = 4,157#
ONn = 0.65*4,157# = 2,702#
Ns = ONn/1.6 = 2,702#/1.6 = 1,689#
Moment resistance for anchors at 6" on center:
0Mn = 2*2,702#*[1.31-0.5*2*2,702/(2*0.85*3ksi*12)] = 6,560"# = 580'#/ft
Ma = OMn/%= 6,560"#/1.6 = 4,350"# = 362.5'#/ft
NOTE: When attached to concrete alternative anchors may be designed in accordance to the
anchor manufacturer's engineering reports that can develop greater strength.
Maximum allowable wind loads (ASD):
36" height: w = 362.5#'/(0.55*32)= 73.23 psf
42" height: w = 362.5#'/(0.55*3.52) = 53.8 psf
6" O.C. Anchor Spacing,135" edge spacing:
ANcg= (6)*(1.5*2.5+1.75) = 33in2 Minimum allowable edge distance is 175"
Nib = 33/56.25*1.0*1.0*1.0*5,196 = 3,048#
ON. = 0.65*3,048# = 1,981#
Ns = ¢Nn/1.6 = 1,981#/1.6 = 1,238#
OM. = 2*1,981#*[1.31-0.5*2*1,981/(2*0.85*3ksi*12)] = 5,062"# = 421.83'#/ft
Ma = 0MA = 5,062"#/1.6 = 3,164"# = 263.64'# /ft
Maximum allowable wind loads (ASD) for anchors at 6" o.c. 1.75" edge distance:
36" height: w = 263.64#'/(0.55*32)= 53.3 psf
42" height: w = 263.64#'/(0.55*3.52) = 39.1 psf
FASCIA (SIDE) MOUNTED B6S BASE SHOE
For side mounted base shoe the allowable loads are the same as for the B5S shoe.
Alternative anchors will provide the same allowable loads as for the B5S base shoe therefore
refer to the B5S calculations for the fascia (side) mounted options.
EDWARD C. ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329
253-858-0855/Fax 253-858-0856 elrobison@narrows.com
C.R. Laurence Glass Rail System (GRS) and Taper-Loc@ 06/19/2014
B7S 2 3/4" X 4 1/8" GLASS BALUSTRADE BASE SHOE
Heavy Duty Square Base Shoe
6063-T52 Aluminum extrusion
Fully tempered glass glazed in place, either wet glazing cement
or Taper-Loc®.
Shoe strength = Vertical legs:
Glass reaction by bearing on legs to form couple. Allowable
moment on legs:
Ma=SiFy
Ft = Fc = 12.5 ksi (ADM Table 2-23, Sec 3.4.4 and 3.4.13)
Si = 12"*0.75"2*/6 =1.125 in3/ft
Ma = 12.5 ksi*1.125 in3/ft = 14,062#"/ft
Leg shear strength @ groove
twin = 0.343"
Fv= 5.5 ksi (ADM Table 2-23, Sec 3.4.20
Vaii = 0.75"* 12"/ft*5.5 ksi = 49.5 k/ft
Base shoe anchorage:
Typical rail section: 42" high 50 plf top rail load or 25 psf panel load
Mt = 50plf*42" = 2,100"#/ft
Mw = 25 psf*3.5'*21" = 1,837.5"#
Typical Anchor load — 12" o.c. — Ta = 2,100"#/1.375" = 1,527#
Page 42 of 55
W" Cap Screw to Steel Supports - See B5S for anchor strength calculation.
Maximum allowable moment for 1/2" cap screws (Ta = 3,592#) 12" on center spacing and direct
bearing of base shoe on steel:
Ma = 3,592#*[1.375"-0.5*3,592/(30ksi*12)] = 4,921"# = 410.091# per anchor
Maximum allowable wind loads (ASD) for Cap screws at 12" o.c.:
36" height: w = 410.09#'/(0.55*32) = 82.8 psf
42" height: w = 410.09#'/(0.55*3.52) = 60.9 psf
Maximum allowable wind loads (ASD) for Cap screws at 6" o.c.:
Ma = 2*3,592#*[1.375"-0.5*2*3,592/(30ksi*12)] = 9,806"# = 817.19'#/ft
36" height: w = 817.19#'/(0.55*32) = 165.1 psf
42" height: w = 817.19#'/(0.55*3.52) = 121.3 psf
Required spacing to develop the full glass strength for wind loading (ASD):
s = 9,806/9,926*6" = 5.93" o.c.
EDWARD C. ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329
253-858-0855/Fax 253-858-0856 elrobison@narrows.com
C.R. Laurence Glass Rail System (GRS) and Taper-Loc® 06/19/2014
Page 43•of55
B7S Surface Mounted Continued:
For anchor into concrete:
3/8" diameter Screw -in anchor Hilti Kwik HUS-EZ (KH-EZ) %8" x 4" manufactured by Hilti in accordance with ESR-3027 or Hilti HSL-3 M8 x 3-3/4" anchor in accordance with ESR-1545.
Strength calculated in accordance with ACI 318-08 Appendix D..
Fe z 3,000 psi
2-1/2" effective embedment
- - ONsa = 0:65*4,400#-= 2,860# - - - - For concrete breakout strength:
Nob = [AN./ANca]tP d Nq)o,Nq)y NNb
ANC= (1.5*2.5"*2)*(1.5*2.5*2) = 56.25in2 Edge distance = 3 3/a"
ANco= 9*2.52 = 56.25in2
Camin = 1.5*2.5" = 3.75
Cae = 2:5*2.5" = 6.25
cped,N = 1.0
(N.N = 1.0 (from ESR-3027)
tPsn,N= 1.0 (from ESR-3027)
Nb = 24*1.0*1�3000*2.51•5 = 5,196#
Nob = 56.25/56,25*1.0*1.0*1.0*5,196 = 5,196#
From ESR-3027 anchor pull out does not control design
ON, = 0.65*5,196# = 3,377#
Ns = ONn/1.6 = 3,377#/1.6 = 2,111#
Anchor steel strength will not control
Moment resistance of each anchor:
For surface mounted
OMo = 3,377#*[1.375-0.5*3,377/(2*0.85*3ksi*12)] = 4,550"# = 379.2'# per anchor
Ma = OMo/% = 4,550"#/1.6 = 2,844"# = 237.0'# (at 1' spacing doesn't develop full allowable
glass load for 5/8" or 3/4" glass.)
Maximum allowable wind loads (ASD) for concrete anchors at 12" o.c. and 3 Y44" edge distance:
36" height: w = 237.0#'/(0.55*32) = 47.9 psf
42" height: w = 237.0#'/(0.55*3.52) = 35.2 psf
Minimum acceptable edge distance is 2.35" For 42" guard height and 12"o.c. spacing.
ANC= (1.5*2.5"*2)*(1.5*2.5+2.35) = 45.75in2 Minimum edge distance is 2.35"
Nob = 45.75/56.25*1.0* 1 .0*1 .0*5,196 = 4,226#
ON. = 0.65*4,226# = 2,747#
Ns = oNo/1.6 = 2,747#/1.6 =1,717#
OM, = 2,747#*[1375-0.5*2,747/(2*0.85*3ksi* 12)] = 3,715"# = 309.64 per anchor
EDWARD C. ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329
253-858-0855/Fax 253-858-0856 elrobison@narrows.com
C.R. Laurence Glass Rail System (GRS) and Taper -Loco 06/19/2014
B7S Surface Mounted to Concrete Continued:
Ma = WMn/;, = 3,715"#/1.6 = 2,322"# = 193.5 (at
load.)
Maximum allowable wind loads (ASD):
36" height: w = 193.5#'/(0.55*32) = 39.1 psf
42" height: w = 193.5#'/(0.55*3.52) = 28.7 psf
Page 44 of 55
spacing doesn't develop full allowable glass
6" O.C. Anchor Spacing, 3.75" edge spacing:
ANc= (6)*(1.5*2.5*2) = 45in2 Edee distance = 3 3/4"
Nn6 = 45/56.25* 1.0* 1.0* 1 .0*5,196 = 4,157#
0Nn = 0.65*4,157# = 2,702#
Ns = 0Nn/1.6 = 2,702#/1.6=1,689#
Moment resistance for anchors at 6" on center:
OMn = 2*2,702#*[1.375-2*0.5*2,702/(2*0.85*3ksi*12)] = 7,192"# = 599.33'#/ft
Ma = OMn/X = 7,192"#/1.6 = 4,49511# = 374.58'#/ft
NOTE: When attached to concrete alternative anchors may be designed in accordance to the
anchor manufacturer's engineering reports that can develop greater strength.
Maximum allowable wind loads (ASD):
36" height: w = 374.58#'/(0.55*32)= 75.7 psf
42" height: w = 374.58#1/(0.55*3.52) = 55.6 psf
6" O.C. Anchor Spacing, 235" edge spacing:
ANcg= (6)*(1.5*2.5+2.35) = 36.6in2 Edge distance = 235"
Nib = 36.6/56.25*1.0*1.0*1.0*5,196 = 3,381#
ON. = 0.65*3,381# = 2,198#
Ns = ¢Nn/1.6 = 2,198#/1.6 = 1,373#
OM, = 2*2,198#*[1.375-0.5*2*2,198/(2*0.85*3ksi*12)] = 5,887"# = 490.55'#
Ma = 0Mn/X = 5,887"#/1.6 = 3,679"# = 306.59'#
Maximum allowable wind loads (ASD) for anchors at 6" o.c. 2.35" edge distance:
36" height: w = 306.59#'/(0.55*32)= 61.9 psf
42" height: w = 306.59#'/(0.55*3.52) = 45.5 psf
EDWARD C. ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329
253-858-0855/Fax 253-858-0856 ehobison@narrows.com
C.R. Laurence Glass Rail System (GRS) and Taper-Loc® 06/19/2014
Page 45 of 55
B7S Surface Mounted to Concrete Continued:
6" O.C. Anchor Spacing,1.75" edg6 spacing:
ANcg= (6)*(1.5*2.5+1.75) = 33in2 Minimum all edge distance is 1.7511
NO = 33/56.25*1.0*1.0*1.0*5,196 = 3,048#
ONn = 0.65*3,048#=1,981#
Ns = ONn/1.6 = 1,981#/1.6=1,238#
0Mn = 2*1,981#*[1.375-0.5*2*1,981/(2*0.85*3ksi*12)] = 5,320"# = 443.29'#
Ma = 0Mn/X = 5,320"#/1.6 = 3,325"# = 277.06'#
Maximum allowable wind loads (ASD) for anchors at 6" o.c. 1.75" edge distance:
36" height: w = 277.06#'/(0.55*32)= 56.0 psf
42" height: w = 277.06#'/(0.55*3.52) = 41.1 psf
FASCIA (SIDE) MOUNTED B7S BASE SHOE
For side mounted base the allowable loads are the same as for the 2-1/2" wide shoe.
Alternative anchors will provide the same allowable loads as for the 2-1/2" wide base shoe
(B5S).
EDWARD C. ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329
253-858-0855/Fax 253-858-0856 elrobison@narrows.com
C.R. Laurence Glass Rail System (GRS) and Taper-Loc@ 06/19/2014
DRAIN BLOCKS
Drain blocks may be used under the base shoe to provide
a water drainage path on exterior decks.
When used on steel substrate there is no reduction in the k `
allowable loads. Ifidth
When used on concrete the allowable loads are adjusted as follows:
BSS, BSG, B5T and B5A base shoes: 2.5"x 2.25"
For 3-3/4" anchor edge distance
Page 46 of 55
W.
O l�IFck1
Length
Maximum allowable wind loads (ASD) for 12" spacing:
Ma = 2,111#*[1.25-0.5*2,111/(2*0.85*3ksi*2.25)] = 2,445"# = 203.7'# per anchor
36" height: w = 203.7'#/(0.55*32) = 41.2 psf
42" height: w = 203.7'#/(0.55*3.52) = 30.2 psf
Maximum allowable wind loads (ASD) for 6" spacing:
Ma = 2*1,689#*[1.25-0.5*1,689/(2*0.85*3ksi*2.25)] = 3,974"# = 331.16'# per anchor
36" height: w = 331.16'#/(0.55*32) = 66.9 psf
42" height: w = 331.16'#/(0.55*3.52) = 49.2 psf
For minimum edge distance = 2.35"
Maximum allowable wind loads (ASD) (12" o.c. spacing):
Ma = 1,717#*[1.25-0.5*1,717/(2*0.85*3ksi*2.25)] = 2,018"# = 168.2'# per anchor
Anchor spacing must be decreased for 42" guard height when 50 plf live load applies.
S50-42= 2,018"#/ft/(50*42")*l2 = 11.5" o.c. (use 11 anchors for 10' section)
36" height: w=168.2#'/(0.55*32) = 34.0 psf
42" height: w=11/10* 168.2#'/(0.55*3.52) = 27.5 psf (11 anchors per 10' section)
Maximum allowable wind loads (ASD) for 6" spacing:
Ma = 2* 1,373#*[1.25-0.5* 1,373/(2*0.85*3ksi*2.25)] = 3268"# = 272.35'# per anchor
36" height: w = 272.35'#/(0.55*32) = 55.0 psf
42" height: w = 272.35'#/(0.55*3.52) = 40.4 psf
EDWARD C. ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329
253-858-0855/Fax 253-858-0856 ehrobison@narrows.com
C.R. Laurence Glass Rail System (GRS) and Taper -Loco 06/19/2014
Page 47 of 55
B5L base shoe: 2.25" x 2.5"
For 3-314" anchor edge distance
Maximum allowable wind loads (ASD) for 12" spacing:
Ma = 2,111#*[1.125-0.5*2,111/(2*0.85*3ksi*2.5)] = 2,200"# = 183.3'# per anchor
36" height: w = 183.3'#/(0.55*32) = 37.0 psf
42" height: w = 183.3'#/(0.55*3.52) = 27.2 psf
Maximum allowable wind loads (ASD) for 6" spacing:
M, = 2*1,689#*[1.125-0.5*1,689/(2*0.85*3ksi*2.5)] = 3,577"# = 298.04'# per anchor
36" height: w = 298.04#/(0.55*32) = 60.2 psf
42" height: w = 298.04'#/(0.55*3.52) = 44.2 psf
For minimum edge distance is 235"
Maximum allowable wind loads (ASD) for 12" O.C. spacing:
Ma = 1,717#*[1.125-0.5*1,717/(2*0.85*3ksi*2.5)] = 1,816"# = 151.3'#per anchor
Anchor spacing must be decreased for 42" guard height when 50 plf live load applies.
S50-42= 1,816"#/ft/(50*42")*12 = 10-3/8" o.c. (use 12 anchors for 10' section)
36" height: w = 151.3#/(0.55*32) = 30.6 psf
42" height: w = 12/10*151.3#'/(0.55*3.52)= 26.9 psf (use 12 anchors for 10' section)
Maximum allowable wind loads (ASD) for 6" spacing:
Ma = 2*1,373#*[1.125-0.5*1,373/(2*0.85*3ksi*2.5)] = 2,941"# = 245.12'# per anchor
36" height: w = 245.12'#/(0.55*32) = 49.5 psf
42" height: w = 245.12'#/(0.55*3.52) = 36.4 psf
EDWARD C. ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329
253-858-0855/Fax253-858-0856 elrobisonCnarrows.com
'C.R. Laurence Glass Rail System (GRS) and Taper-Loc® 06/19/2014 Page 48 of 55
Drain Blocks Continued:
136S base shoe: 2.625"x 2.75"
For 3-3/4" anchor edge distance
Maximum allowable wind loads (ASD) for 12" spacing:
Ma = 2,111#*[1.312-0.5*2,111/(2*0.85*3ksi*2.75)] = 2,611"# = 217.56'# per anchor
36" height: w = 217.56'#/(0.55*32) = 44.0 psf
42" height: w = 217.56'#/(0.55*3.52) = 32.3 psf
Maximum allowable wind loads (ASD) for 6" spacing:
Ma = 2*1,689#*[1.312-0.5*1,689/(2*0.85*3ksi*2.75)] = 4,229"# = 352.38'# per anchor
36" height: w = 352.38'#/(0.55*32) = 71.2 psf
42" height: w = 352.28'#/(0.55*3.52) = 52.3 psf
For minimum edge distance is 235"
Maximum allowable wind loads (ASD)(12" o.c. spacing):
Ma = 1,717#*[1.312-0.5*1,717/(2*0.85*3ksi*2.75)] = 2,148"# = 178.97'# per anchor
36" height: w = 178.97#'/(0.55*32) = 36.2 psf
42" height: w = 178.97#'/(0.55*3.52) = 26.6 psf
Maximum allowable wind loads (ASD) for 6" spacing:
Ma = 2*1,373#*[1.312-0.5*1,373/(2*0.85*3ksi*2.75)] = 3,468"# = 289.03'# per anchor
36" height: w = 289.03'#/(0.55*32) = 58A psf
42" height: w = 289.03'#/(0.55*3.52) = 42.9 psf
B7S base shoe: 2.75" x 2.625"
For 3-3/4" anchor edge distance
Maximum allowable wind loads (ASD) for 12" spacing:
Ma = 2,111#*[1.375-0.5*2,111/(2*0.85*3ksi*2.625)] = 2,736"# = 228.02'# per anchor
36" height: w = 227.3'#/(0.55*32) = 50.5 psf
42" height: w = 227.3'#*2/3.52 = 37.1 psf
Maximum allowable wind loads (ASD) for 6" spacing:
Ma = 2*1,689#*[1.375-0.5*1,689/(2*0.85*3ksi*2.625)]= 4,432"# = 369.31'# per anchor
36" height: w = 369.31'#/(0.55*32) = 74.6 psf
42" height: w = 369.31'#/(0.55*3.52) = 54.8 psf
EDWARD C. ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329
253-858-0855/Fax 253-858-0856 elrobison@narrows.com
C.R. Laurence Glass Rail System (GRS) and Taper-Loc® 06/19/2014 Page 49 of 55
Drain Blocks Continued:
B7S base shoe:2.75" x 2.625"
For minimum edge distance is 235"
Maximum allowable wind loads ((ASD) 12" o.c. spacing):
Ma = 1,717#*[1.375-0.5*1,717/(2*0.85*3ksi*2.5)] = 2,245"# = 187.1'# per anchor
36" height: w = 187.1#' *2/32 = 41.6 psf
42" height: w = 187.1#' *2/3.52 = 30.5 psf
Maximum allowable wind loads (ASD) for 6" spacing:
Ma = 2*1,373#*[1.375-0.5*1,373/(2*0.85*3ksi*2.625)]= 3,635"# = 302.91'# per anchor
36" height: w = 302.91'#/(0.55*32) = 61.2 psf
42" height: w = 302.91'#/(0.55*3.52) = 45.0 psf
WELD BLOCKS:
When attaching the base shoe to the
appropriate steel weld blocks the 117-73
Taoaw Note t?
strength shall be the same as for the base t+zT a^) weld eiod
shoe attachment to steel substrate.
Weld block size shall be matched to the
base shoe width. 1w,
CONCRETE ANCHORS ADJUSTMENTS
The strength of the post installed mechanical concrete anchors are a direct function of the square
root of the concrete compressive strength:
Pn = f(V f'c)
Thus the allowable loads shown in this report for the base shoes mounted to concrete may be
adjusted for concrete strengths other than 3,000 psi by:
W' = W*-/X
✓3,000
where:
W = allowable wind load (ASD) calculated for the specific base shoe and anchorage
X = f'�; compressive strength of concrete at time the anchor is installed.
Use of other post installed anchors or different embedment conditions require calculations for the
specific condition.
SAND LIGHT -WEIGHT CONCRETE:
Allowable loads to be multiplied by 0.6 when anchors are installed in sand light -weight concrete.
W' = 0.6*W
EDWARD C. ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329
253-858-0855/Fax 253-858-0856 elrobison@narrows.com
C.R. Laurence Glass Rail System (GRS) and Taper-Loc® 06/19/2014 Page 50 of 55
SURFACE MOUNTING BASE SHOES TO WOOD DECKS:
The base shoe overturning resistance develops by forming a couple between the anchor tension
and compression between the base shoe edge and the substrate. Wood doesn't have adequate
bearing compressive strength to reliably develop the requisite compressive strength when surface
mounted. The shoe may be initially installed tight and appear to perform adequately; but cyclic
loading will cause permanent deformation of the wood surface and loss of anchor pretension.
This will result in rotation of the base shoe and increased couple forces resulting in excessive
guard -deflections and possible faildre. For this reason the base shoes should not be surface
mounted directly to wood when moment exceeds 1,000"#/ft.
It is recommended that whenever possible the base shoe should use the fascia mount when
attaching to wood.
When surface mounting to wood a steel or aluminum bar or angle may be installed on the wood
surface first. The bar or angle shall be designed to safely transfer the imposed loads from the
base shoe to the wood deck. Attachment to the bar or angle shall be as specified previously.
Steel
angle
Base Shoe
or plate
bolted
to
wood
deck
Weld Block
with
base
shoe
Steel Plate
by Others
anchored to the plate or angle using 1/2" cap screws
into threaded weld blocks or tapped holes.
EDWARD C. ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329
253-858-0855/Fax 253-858-0856 elrobison@narrows.com
Base Shoe
C.R. Laurence Glass Rail System (GRS) and Taper -Loco 06/19/2014
Surface Mounting Base Shoes to Wood Decks:
Aluminum Angle Bracket Welded to Base Shoe Alternative.
Weld strength calculated in accordance with ADM
7.3.2 Fillet Welds
Base shoe metal - 6063-T52
Angle metal- 6063-T5
__Weld_ metal4043 -
Weld size:
'/4" fillet, throat = 0.251V2 = 0.177"
Design strength: ADM 7.3.2.2
Vw=FswLwe/nu
For shear through weld throat:
Fsw = 11.5 ksi from ADM Table 7.3-1
Vww=11.5ksi*O.177"*12"/1.95=12,526 plf
For base metal shear failure:
F:ow = 11.0 ksi from ADM Table 3.3-2
Vwb = I I.Oksi*0.25"*12"/1.95 = 16,922 plf
Moment overturning of base shoe -
Shear strength of weld restrains base shoe rotation
about opposite corner:
Ma = 12,526plf* 2.5"*4/12 = 10,438"# per 4" bracket
Check strength of weld affected angle:
From ADM Table 2-23 for allowable aluminum stresses
bending of flat element - weld -affected
Ftw = Fcw = 6.5ksi
1/4
Sf = 4*0.3752/6 = 0.09376in3
Maw = 6,500psi* 0.09376in3 = 609"#
Maximum allowable anchor force based on outward force (controls)
Ru = 609"#/0.5"=1,218#
Maximum allowable moment on base shoe per 4" bracket:
Mas,=1,218#*3"+ 609"# = 4,263"#
Allowable moment per foot for brackets at 16" on center
Ma = 4,263/1.3333' = 3,197"#/ft = 266.44'#/ft
Strength for continuous angle:
Mcont = 4,263*12/4 = 12,789"#/ft
2 1/2
L85X5X3/8
6063-T5 ALUMINUM
ANGLE X 4" LONG
@ 16" O.C.
EDWARD C. ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329
253-858-0855/Fax 253-858-0856 ehobison@narrows.com
Page 51 of 55
1/2
C.R. Laurence. Glass Rail System ((jRS) and Taper-Loc® 06/19/2014 Page 52 of 55
Base Shoe'Welded to Alu ninum'Angle Continued:
For wood screws into solid wood (DFL, Southern Pine or equivalent density Gz0.49):
1/4" Wood screws strength in per National Design Specification for Wood Construction:
W = 165 pli embedment From NDS_ Table 11.2B
For dry or interior applications, Cm = 1.0, CD =1.33
Embed depth = 2" thread length typical
W' = 165#/"*2"* 1.33) = 440#
---Moment-resistance per screw = 440#*3" = 1,320"#
Number of screws required to develop the full strength of 4" bracket:
4,263/1,320 = 3.23 Requires 4 screws.
MUMM = 4* 1,320"# = 5,280#
Bearing pressure on wood for maximum bracket moment:
fa = (4,263"#/3')/(4"*2") = 178 psi s 625 psi
Ma; = 4,263/1.3333' = 3,197"#/ft = 266.44'#/ft
Maximum allowable wind loads (ASD) for brackets at 16" on center spacing, dry location:
36" height: w = 266.4'#/(0.55*32) = 53.8 psf
42" height: w = 266.4'#/(0.55*3.52) = 39.5 psf
For exterior wet applications, Cm = 0.7 applies when moisture content of wood may exceed
19%, Cr) = 1.33
Strength of 4 screws:
W"=4*(0.7*1,320) = 3,696"#
Mao = 3,696/1.3333' = 2,772"#/ft = 231.00'#/ft
Maximum allowable wind loads (ASD) for brackets at 16" on center spacing, exterior location:
36" height: w 231.0'#/(0.55*32) = 46.7 psf
42" height: w = 231.0'#/(0.55*3.52) = 34.3 psf
Continuous Aluminum angle -
For continuous angle with screws installed in pairs each leg at 8" on center strength same as
calculated for 4" bracket at 16" on center.
For screw pairs at X inches on center
Maix = 12"/X*(2*1,320"#/12"/ft) = [2,640/X]'#/ft Dry locations
Maox = 0.7*[2,640/X]'#/ft = [1,848/X]'#/ft Exterior locations
For example: X = 4"
Mai4 = [2,640/4]'#/ft = 660.0'#/ft Dry locations
42" height: w = 660.0'#/(0.55*3.52) = 98.0 psf
Mao4 = [1,848/4]'#/ft = 462.0'#/ft Exterior locations
42" height: w = 462.0'#/(0.55*3.52) = 68.6 psf
EDWARD C. ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329
253-858-0855/Fax 253-858-0856 ehobison@narrows.com
C.R. Laurence Glass Rail System (GRS) and Taper-Loc® 06/19/2014 Page 53 of 55
Surface Mounting Base Shoes to Wood Decks:
Base Shoe to Steel Angle Bracket Alternative -
For V2" cap screw into tapped angle strength refer to
appropriate base shoe calculations.
Check angle thickness:
Ftw = Faw = 30ksi (304 SS)
Sf = 4*0.31252/6 = 0.065lin3
OMa = 0.9*1.25*30,000*0.0651in3=2,197"#
Maximum base shoe moment per 4" bracket:
Ma = 2,197/0.5 + 2,197 = 6,591"#
For W' cap screw at 16" o.c into 4" bracket:
For B5S base shoe-
M = 3,592#*[1.25"-0.5*3,592/(30ksi*4)] = 4,436"# _
369.69'# peranchor/bracket
Wood screw pullout strength will control, see
previous page.
For continuous steel angle:
Ma = 6"591*12/3 = 19,773"#
Attachment strength is 372.5'# per cap screw, cap
screw spacing may be calculated from:
scs = (372.5'#)*12
(M'#/ft)
Strength of angle attachment to deck refer to
calculations for aluminum angle, previous page.
Steel angle may be either A36 hot dipped galvanized or 304 or 316 stainless steel.
Minimum angle thickness is I/a" based on cap screw thread engagement.
EDWARD C. ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329
253-858-0855/Fax 253-858-0856 elrobison@narrows.com
C.R. Laurence Glass Rail System (GRS) and Taper-Loc® 06/19/2014 Page 54 of 55
Surface Mounting Base Shoe to Solid Wood:
Interior Locations Only
%" x 5" Lag screws:
Lag withdrawal strength in accordance with the NDS:
W = 367#/in for G = 0.49
CD = 1.33 for guard applications
W' = 367* 1.33 = 489#/in
For 3.5" embedment into solid wood:
Ta = 3.5"*489#/in = 1,712# < 0.75*0.10*45,000psi/1.6 = 2,110#
Bearing strength on wood fa = 625 psi
For lag screws at 12"on center
Mia= 1,678*(1.25-0.5*1,712/(12*625psi) = 1,906"#/ft= 158.8'#
May be used for interior private residence installations only.
Minimum required length:
200#*36"/1,906 = 3.78' for 36" guard height minimum 4 anchors
200#*42"/1,906 = 4.41' for 42" guard height minimum 5 anchors
For lag screws at 6" on center:
Mia = 2*1,678*(1.25-0.5*1,712/(6*625psi) = 3,429"#/ft = 286'#
May be used where 50 plf live load is applicable.
Minimum length
200#*36"/3,429 = 2.1' for 36" guard height minimum 5 anchors
200#*42"/3,429 = 2.45' for 42" guard height minimum 5 anchors
EDWARD C. ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329
253-858-0855/Fax 253-858-0856 elrobison@narrows.com
C.R. Laurence Glass Rail System (GRS) and Taper-Loc® 06/19/2014 Page 55 of 55
INSTALLATION ALONG STAIRS:
For installations along stairs where the bottom shoe fully supports the bottom edge of the glass
and the cap/grab rail is parallel to the base shoe the glass stresses and base shoe loads are the
same as for the standard horizontal installation based on measuring the glass height
perpendicular to the base shoe.
For glass stress and live loads:
When glass height is 5 50" then;6" glass may be used for live loads.
When glass height is 5 64" may use %" glass.
When glass height is 5 77" may use 3/a" glass.
At the maximum heights deflections will control.
Recommend limiting glass heights to:
hg 5 48" for W' glass
hg s 56" for %" HEIGH GLASS
hg s 64" for 3/a"
Verify glass thickness for wind of
loading. eaSESN
Check base shoe anchorage using
the appropriate mounting type and
base shoe.
Irregular glass light shapes or intermittent base shoes are outside of the scope of this report.
EDWARD C. ROBISON, PE, SE
10012 Creviston Dr NW
Gig Harbor, WA 98329
253-858-0855/Fax 253-858-0856 elrobisonC&narrows.com