HomeMy WebLinkAboutR & B WAGNER PAPERWORKI1�
Mill)�
Q, ,oilt,,
R & B Wagner, Inc
C/ dos -bad
'907- ()f®(D
Series: Panel Grip 2 Aluminum Balustrade Railing
System
Client Package
Fenestration Testing Laboratory
8148 N.W. 74`h Avenue
Medley, Florida 33166
Phone: (305) 885-3328
Fax: (305)885-3329
Toll: (888) 819-7877
RevjSWEI) FoR
S®® �C�E �®D�ANCE
E®CC UN'
FILE COPY
Remote Offices: Schaumburg, Illinois (312) 253-7203 Las Vegas, NV (702) 922-7142
Tampa, FL (813) 200-5886 Pensacola, FL (850) 454-1734 Houston, TX (281) 763-0401
xl �'f Bii '� �.t �,�� i?Q ;it' �'` � 9 `'r#�§
k �15 �(�� ��'"����•'�..tis N,�,q �°3
a
q.
l
( IIll�r (•I a_ P-
.. .. Ril'
1 Ili'L.- r (il
Florida State Cert. No.
TST1657
Miami Dade County Cert. No:
14-0806.03
Report Date:
10/1/2015
Completion Date:
8/27/2015
Expiration Date:
8/27/2025
Miami Dade County Auth. No:
-FTL-15038
Page No.
Page 1 of 14
Lab. Number:
8442
Project Number:
15-5732
OFFICIAL TEST REPORT
MANUFACTURER: R & B Wagner, Inc
SPECIFICATIONS:
Florida Building Code
TAS 201, TAS 202 (Loads)
ANSI Z97.1, concentrated load
ADDRESS: 10600 West Brown Deer Road
PROJECT:
Florida State Approval
Milwaukee, Wisconsin 53224
Miami Dade County
Table of Contents
Sample A-1
Page
Rev
Page Rev
Description of Test Sample
2
Revision Table
12
Glazing
2
Notes Table
13
Additional Information
2
Remarks Table
14
Test Sample Installation
2
Results Sample A-1
Concentrated Load Test FBC section 1618.4.6.1
3
Concentrated Load Test FBC section 1618.4.6.1
3
1/2 Structural Load Test Positive TA5202
4
Design Load Test Positive TAS 202
4
1/2 Structural Load Test Negative TAS202
4
Design Load Test Negative TAS 202
5
Uniform Structural Load Test Positive TAS 202
6
Uniform Structural Load Test Negative TAS 202
7
Drop Test ANSI Z97.1
8
Large Missile Impact TAS 201
9
Concentrated Load Test FBC section 1618.4.6.1
10
Concentrated Load Test FBC section 1618.4.6.1
10
Design Load Test Positive TA5 202
11
Design Load Test Negative TAS 202
12
Florida State Cert. No. TST1657
Miami Dade County Cert. No: 14-0806.03
Report Date: 10/1/2015
Completion Date: 8/27/2015
Expiration Date: 8/27/2025
Miami Dade County Auth. No: FTL-15038
Page No. Page 2 of 14
Q v Lab. Number: 8442
m Project Number: 15-5732
nvrirml TFCT RrPnRT
DESCRIPTION OF SAMPLE
Model Designation:
Series: Panel Grip 2 Aluminum Balustrade Railing System
Overall Size:
12'-2 1/16" (146 1/16") by 3'-7 13/16" (43 13/16") high
Sample A-1
Glazing
Glazing Location
Glazing Material Glazing Compound
Compound Color
All three lites
*13/16" nominal laminated glass none
n/a
composed of (2) 3/8" tempered glass
Interlaying Film: *0.060" **DuPont SentryGlas I Laminator: **Oldcastle
Glazing Method: The glass was secured using a single row of **PanelGrip" located 3 3/4", 11 1/8", 23 3/8", 32
1/2", 41 1/8", 53 1/4", 64 1/16", 74 11/16", 83 1/8", 9215/16", 1011/16", 111", 122 3/4", 131", and 1413/8"
from left. Each **PanelGripT" is secured using one 1/4-20 by 11/2" long socket head machine screws with
washer and nut.
Pocket glazed at the top with a *1" glazing penetration using glazing tape on the interior, exterior and glazing
pocket.
Daylight Opening:
I Right lite: 47 5/8" by 38 5/16" high
Left and center lite: 47 7/16" by 38 5/16" high
Additional Information
The sample was testing using a 1461/16" long stainless steel hand rail.
Sample Installation
The sample was installed into a 4,000 psi concrete test slab. The shoe base was installed using a single row 5/8"
by 61/8" H W H wedge bolts located 21/8", 6 3/4",12 3/4", 18 9/16", 24 3/4", 30 5/8", 36 3/4", 42 5/8", 48
5/8", 54 3/4", 60 3/4", 66 3/4", 72 3/4", 78 3/4", 84 3/4", 90 3/4", 96 7/8",102 3/4",114 5/8",120 3/4",126
3/4",132 5/8", 138 5/8" and 143 5/8" from left.
Quality Accuracy Assurance
Fenestration Testing Laboratory, Inc.
8148 N.N. 74th Avenue dledley, FL 33166 Phone: (305) 885-3328 Fax: (305) 885-3329 (888) 819-7877
e-mail: clientseruices@ftl-inc.com www.fti-inc.com
Florida State Cert. No.
TST1657
Miami Dade County Cert. No:
14-0806.03
Report Date:
10/1/2015
Completion Date:
8/27/2015
Expiration Date:
8/27/2025
Miami Dade County Auth. No:
FTL-15038
Page No.
Page 3 of 14
Lab. Number:
8442
Project Number:
15-5732
nrrirml TFGT RFPng?T
Sample: A-1 I Temperature: 837
Barometric Reading: 30.08 inches Hg
Title of Test
L Load
Notes
Concentrated Load Test
400.0 Ibs
As per FBC section 1618.4.6.1. A horizontal load
was applied at the corner of the hand rail
— — — — — — 1
II �I
II I�
Reading#
Deflection
Permanent Set
Results
Add. info
1
1.389"
0.030"
1 Passed
Sample: A-1 I Temperature: 83"F
Barometric Reading: 30.08 inches Hg
Title of Test
Load
Notes
Concentrated Load Test
1,216.0 Ibs
As per FBC section 1618.4.6.1. A horizontal load
was applied at center of the hand rail
II I�
-- - -
Reading#
Deflection
Permanent Set
Results
Add. Info
1
2.250"
0.201"
Passed
1
2
0.049"
0.002"
Passed
Quality Accuracy Assurance
Fenestration Testing Laboratory, Inca
8148 NIY. 74th Avenue Uedteu, FL 33166 Phone: (305) 885.3328 Fax: (305) 885-3329 (888) 819-7877
e-maw chentservices(ap-inc.corn www.ii-inc.com
Florida State Cert. No.
TST1657
Miami Dade County Cert. No:
14-0806.03
Report Date:
10/1/2015
Completion Date:
8/27/2015
Expiration Date:
8/27/2025
Miami Dade County Auth. No:
FTL-15038
Page No.
Page 4 of 14
Lab. Number:
8442
Project Number:
15-5732
r%9=rIAI TccT nconoT
Sample: A-1
Temperature: 837
Barometric Reading: 30.08 inches Hg
Title of Test
Pressure
Notes
1/2 Structural Load Test Positive Load
40.0 psf
Results I
Passed
Sample: A-1 I Temperature: 83.0"F
Barometric Reading: 30.08 inches Hg
Title of Test
Pressure
Notes
Design Load Test Positive Load
40A sf
f 0
0
Reading#
Deflection
Permanent Set
Results
Add. Info
1
1.503"
0.030"
Passed
2
0.060"
0.005"
Passed
Actual Movement
Actual Set
Recovery
Additional Info.
2.) 0.060"
0.0051,
Sample: A-1
Temperature: 85-F
Barometric Reading: 30.04 inches Hg
Title of Test
Pressure
Notes
1/2 Structural Load Test Negative Load
40.0 psf
Results
Passed
Quality Accuracy Assurance
Fenestration Vesting Laboratory, Inc.
8148 NAV. 741h Avenue Aledleu, F1.33166 Phone:1305) 885.3328 Far: (3051885-3329 18881819.7877
e-mad: caencseruices tiu-Inc.com wwwJu-lnc.com
Florida State Cert. No.
TST1657
Miami Dade County Cert. No:
14-0806.03
Report Date:
10/1/2015
Completion Date:
8/27/2015
Expiration Date:
8/27/2025
Miami Dade County Auth. No:
FTL-15039
Page No.
Page 5 of 14
Lab. Number:
8442
Project Number:
15-5732
ncririm TPfT R mnwr
Sample: A_-1 I Temperature:_ 85"F
Title of Test Pressure
Baro_metr_ic Reading: 30.04 inches Hg
Notes
_ Design Load Test Negative Load
40.0 psf
I p II I
I V II I
i C
Reading#
Deflection
Permanent Set
Results
Add. Info
1
1 1.515"
0.026"
Passed
2
0.027"
0.001"
Passed
Actual Movement
Actual Set
Recovery
Additional Info.
2.) 0.027"
0.001"
96.2%
guanty Accuracy assurance
a ¢'i�i' ..a t�a.U0
81481`.W 741h Avenne Aiedleu. FL 33166 Phmu_ (305)885-3328 Paz f305) 885.3329 (8881819-7877
Florida State Cert. No.
TST1657
Miami Dade County Cert. No:
14-0806.03
Report Date:
10/1/2015
Completion Date:
8/27/2015
Expiration Date:
8/27/2025
Miami Dade County Auth. No:
FTL-15038
Page No.
Page 6 of 14
Lab. Number:
8442
Project Number:
15-5732
OFFICIAL TEST REPORT
Sample: A-1 L Temperature: 83°F
Barometric Reading: 30.08 inches Hg
Title of Test
Pressure
_
Notes
Uniform Structural Test Positive Load
80.0 psf
I N II I
I N II I
I II II I
_ Reading#
Deflection
Permanent Set
Results
Add. Info
1
3.375"
0.210"
Passed
2
0.190"
0.010"
Passed
_
Actual Movement
Actual Set
Recovery
Additional Info.
2.)0.190"
0.010"
94.7%
Quality Accuracy Assurance
G LScc...s.s
8148,MV 74ihAvenue Sledleu.PL33166 Phone (3051885-3328 Far:130ai885.3329 (8881819-7877
Florida State Cert. No. TST1657
Miami Dade County Cert. No: 14-0806.03
Report Date: 30/1/2015
Completion Date: 8/27/2015
Expiration Date: 8/27/2025
Miami Dade County Auth. No: FTL-15038
Page No. Page 7 of 14
Lab. Number: 8442
Project Number: 15-5732
OFFICIAL TFgT RFPORT
Sample: A-1
I Temperature: 85"F
Barometric Reading: 30.04 inches Hg
Title of Test
_
Pressure
Notes
Uniform Structural Test Negative Load
80.0 psf
Reading#
Deflection
Permanent Set
Results
Add. info
1
2.875"
0.204"
Passed
_
2
0.048"
0.004"
Passed
Actual Movement
Actual Set
Recovery
Additional Info.
2.) 0.048"
0.004"
91.7
Qualify Accuracy Assurance
It
Florida State Cert. No. TST1657
Miami Dade County Cert. No: 14-0806.03
Report Date: 10/1/2015
Completion Date: 8/27/2015
Expiration Date: 8/27/2025
Miami Dade County Auth. No: FTL-15038
Page No. Page 8 of 14
Lab. Number: 8442
Project Number: 15-5732
ntriri41 TFCT DFDnDT
Sample: A-1 Temperature:
79"F Barometric Reading: 29.99 inches H
Title of Test
Notes
Drop Test
As per FBC section 1618.4.6.3
Ippi
Drop p
Results
1
Passed
Impacted center of lite. After impact the glass did not break.
2
Passed
Impacted center of lite. After impact the glass did not break.
3
Passed
Impacted center of lite. After impact the glass did not break.
Quality Accuracy Assurance
1i elLeSLY-UL44OUL I welly Idavormory, lue,
Florida State Cert. No.
TST1657
Miami Dade County Cert. No:
14-0806.03
Report Date:
10/1/2015
Completion Date:
8/27/2015
Expiration Date:
8/27/2025
Miami Dade CountyAuth.No:
FTL-15038
Page No.
Page 9 of 14
Lab. Number:
8442
Project Number:
15-5732
nrcir1Al TFGT DFDnDT
Sample: A-1 I
Temperature: 83.17
Barometric Reading: 30.01 inches Hg
Title of Test
Notes
Large Missile Impact Test
Missile Weight
Missile
9.25 pounds
2" by 4" by
92" long
I
L
—
I�
Impact
Speed
Results
Add. Info
1
49.6 ft/sec
Passed
2
49.8 ft/sec
Passed
3
49.9 ft/sec
Passed
4
50.0 ft/sec
Passed
5
49.8 ft/sec
Passed
6
49.9 ft/sec
Passed
Duality Accuracy Assurance
e: A-1 l Temperature: 83'F _
Title of Test Load
Concentrated Load Test I 600.0 Ibs
Florida State Cert. No.
Miami Dade County Cert. No:
Report Date:
Completion Date:
Expiration Date:
Miami Dade County Auth. No:
Page No.
Lab. Number:
Project Number:
TST1657
14-0806.03
10/1/2015
8/27/2015
8/27/2025
FTL-15038
Page 10 of 14
8442
15-5732
Reading: 29.98 inches Hg
As per FBC section 1618.4.6.1. A horizontal load
was applied on center of the hand rail
-- ----- -- ---
Readingfi Defledion Permanent Set Results Add. Info
1 1.629" None Passed
A-1
29.98inches
Title of Test Load _Notes __
Concentrated Load Test 200.0 Ibs As per FBC section 1618.4.6.1. A horizont;
was applied at the corner of the hand rail
l ---ter----�r �1--'-- -
II� �I II
L � F
p II
l
load
I- Readingit I 1D Election — I 0 rm2 mnt set .I Passed — — —I-Add. Info — -- _—I
tuutti4 .l a act, �IssLiru ,ce
ebp ,
6904.v
Florida State Cert. No.
TST1657
Miami Dade County Cert. No:
14-0806.03
Report Date:
10/1/2015
Completion Date:
8/27/2015
Expiration Date:
8/27/2025
Miami Dade CountyAuth. No:
FTL-15038
Page No.
Page 11 of 14
Lab. Number:
8442
Project Number:
15-5732
ncrirl Al TFCT aCDnnT
Sample: A-1 I Temperature: 797
Barometric Reading: 29.97 inches Hg
Title of Test
Pressure
Notes
Design Load Test Positive Load
I 40.0 psf __
B
li
I
Reading#
Deflection
Permanent Set
Results
Add. Info
1
2.500"
0.003"
Passed
0.085"
0.007"
Passed
ual Movement
rC
Actual Set
Recovery
Additional Info.
0.085"
0.007"
91.8%
4 s.n,a
Florida State Cert. No. TST1657
Miami Dade County Cert. No: 14-0806.03
Report Date: 10/1/2015
Completion Date: 8/27/2015
Expiration Date: 8/27/2025
Miami Dade CountyAuth. No: FTL-15038
Page No. Page 12 of 14
Lab. Number: 8442
Project Number: 15-5732
urr1UAL ltbl KLFUKI
Sample: A-1 I Temperature: 88°F
Barometric Reading: 30.00 inches Hg
____ Title of Test
Pressure
Notes
Design Load Test Negative Load
40.0 psf
"------IF—
II
p�
II
I�
I�
II
I'
Reading# Deflection
Permanent Set
Results
Add. Info
1 2.000"
0.002"
Passed
2 J 0.016"
0.003"
Passed
Actual Movement
Actual Set
Recovery
Additional Info.
2.) 0.016"
0,003"
81.2%
Revision
Description
Author
Effective Date
0
Initial Release
Ms. Iliana Sanchez
10/1/2015
f
e
s
r
F
M
Florida State Cert. No. TST1657
Miami Dade County Cert. No: 14-0806.03
Report Date: 10/1/2015
Completion Date: 8/27/2015
Expiration Date: 8/27/2025
Miami Dade County Auth. No: FTL-15038
Page No. Page 13 of 14
Lab. Number: 8442
Project Number: 15-5732
Notes
' designates measurements by laboratory
" as per manufacturer
Fenestration Testing Laboratory Inc., does not have, nor does it intend to acquire or will acquire, a financial
interest in any company manufacturing or distributing products tested or labeled by the Fenestration Testing
Laboratory Inc. Fenestration Testing Laboratory Inc., is not owned, operated or controlled by any company
manufacturing or distributing products it tests or labels.
Drawings referenced in this document are an integral part of this report, therefore, are required when distributing
this test report. Test results obtained represent the actual value of the tested specimens and do not constitute
opinion, endorsement or certification by this laboratory.
This test report is considered the exclusive property of the client named herein and is applicable to the sample
tested. This report may not be reproduced without the approval of Fenestration Testing Laboratory, Inc.
At conclusion of above tests, there was no apparent damage to fasteners and after impact the glass did break,
but remained in place and there wasn't any apparent tear in the inter layer film. Test specimens were covered
with 1.5 mil plastic sheeting to seal from air leakage when load test were performed, however this had no effect
s >-
P Florida State Cert. No. TST1657
Miami Dade County Cert. No: 14-0806.03
Report Date: 30/1/2015
Completion Date: 8/27/2015
Expiration Date: 8/27/2025
Miami Dade County Auth. No: FTL-15038
Page No. Page 14 of 14
Lab. Number: 8442
Project Number: 15-5732
OFFICIAL TEST REPORT
Remarks
Detailed drawings will be retained by Fenestration Testing Laboratory for a period of one year from the original
test date, and test report for a period of four years. Due to the code cycle change it is recommended that this
report be evaluated during the lifespan of this document.
This product was tested in accordance with the Florida Building Code (2014) TAS 202 (loads) and TAS 201, with
the deviation that only one sample was tested.
This product was tested in accordance with ANSI Z-97.1-09 (FBC section 1618.4.6.3) with no deviations.
This product was tested in accordance with the Florida Building Code section 1618.4.6.1(concentrated load
test) with no deviations.
Testing was conducted as per instructions received from the manufacturers company representative.
Witnessed by:
Ms. Idalmis Ortega, P.E.
Technicians:
Mr. Harold Anacona
Mr. Gerresse Lee
FENESTRATION TESTING LABORATORY, INC.
f l .
Mr. Manny Sanchez
Chief Executive Officer
RICE r't
E/VGINEERING
ASTM E985 TEST REPORT
GR2457 HCB-10 Base Shoe and PG2475 Pad and Isolator
Rendered to:
R&B Wagner, Inc.
10600 W Brown Deer Rd
Milwaukee, WI 53224
Report Number:
Set-up Date:
Test Date:
Report Date:
R15-06-210
09/25/2015
09/25/2015
10/06/2015
Project Identification: GR2457HCB-10 base shoe with PG2475 pad and isolator ASTM E985 Testing
Project Scope: Rice Engineering was contacted by R&B Wagner, Inc. to witness testing of their GR2457
base shoe guardrail system, specifically the amount of deflection that would occur in 1/2" thick (9/16")
tempered SGP laminated glass (1/4' / 0.060" SGP / 1/4") when pulled to design loads as described in
ASTM E985 "Standard Specification for Permanent Metal Railing Systems and Rails for Buildings". On
September 25, 2015, Joseph Bauer of Rice Engineering witnessed testing for the three different configurations.
The testing was performed on -site at the R&B Wagner facility and was conducted by Kelly Bauserman.
Conclusions: The SGP laminated glass lite was tested to a maximum deflection of 2.347" on the end and
1.785" at the center (ultimate test load of 365 Ibf). The allowable deflection was 3.5" at the left and 2.25" at the
center. The residual deflection (measured at 90 Ibf) was 0.073". The allowable residual deflection was 0.45".
There were no signs of deformation on the base shoe or any problems with the pad and isolators, therefore
1/2" thick (9/16") tempered SGP laminated glass passed the ASTM E985 test.
Prepared & Witnessed By:
Joseph D. Bauer, Wisconsin P.E.
Report No: R15-06-210 October 6, 2015
G'"3
PO Box 423 1 BUTLa a, WI I 53007
UUU �J YYYY iiii
10600 W Dn__ Dn rt w. I mmwA rna, O 1 53224
,. :....
PB 414.214. 0444 FAX 414.214.1326
MASTER TABLE
ZERO POINT FOR CALCULATIONS
Height of Rat? in.
42
Length of Rail in.)
48
Max Left Deflection [h/121 (in.)
3.5
Max Mid Deflection
[ /24 + /96 in
Z25
Max Residual Deflection
20% of Max Mid in
0.45
Front
All inputs should be unadjusted
Actual
Actual
Actual
Left 2 (If
Mid
Left I §
(f pcable)
read outs from test
lbsf
lbsf
lbsf
Gcable)
Deflection Reading @ 0 lbsf
0
4.219
0
4.484
0
4.467
Deflection Reading @ Pre -Load
180 lbsf)
179
3.037
180
Z942
180
Z921
Deflection Reading @ Released
Test Load 1/2 Pre -load
3.585
90
3.619
90
3.585
Deflection Reading @ 150 lbsf
151
1 3.223
153
1 3.147
152
3.314
Deflection Reading @ 200 lbsf
200
2916
203
Z752
202
2.741
Deflection Reading @ 250 loaf
249
2-601
255
2331
255
Z328
Deflection Reading @300lbsf
301
2266
300
1.977
302
1.954
Deflection Reading
@ Ultimate Test Load 365 lbs
365
1.876
364
1.474
365
1.465
Deflection Reading @ Released
Test Load 1/2 Pre -load
91
3.478
90
3.549
92
3512
Back
All inputs should be unadjusted
Actual
Actual
Actual
Left 2 (If
read outs from test
lbsf
Mid
lbsf
Left (IfApp&able)
Ibsf
Applicable)
Deflection Reading @ 0 lbsf
0
4.282
0
4.389
0
4342
Deflection Reading @ Pre -Load
181
3.029
185
2780
180
Z753
180 lbsf)
Deflection Reading @ Released
lest Load (1/2 Pre -load)
92
3.578
89
3.514
90
3.509
Deflection Reading @ 150 lbsf
151
3.202
155
1 3.022
151
3.010
Deflection Reading @ 200 lbaf
200
2891
200
Z642
202
2567
Deflection Reading @ 250 lbsf
252
Z551
250
Z202
252
Z134
Deflection Reading 300 lbsf
300
2232
301
1.76
300
1.714
Deflection Reading @
Ultimate Test Load 365 lbs
365
1.793
364
1.215
365
1.162
Deflection Reading @ Released
Test Load 1/2 Pre-load)3.533
91
90
3.509
90
3.480
p tY _6
6 fi ��GasFFG 9 9 dm'�% 4 1
PO sox 423 1 BUTLER, W1 1 53oo�
10 0 W B.EW Deer ROAD I Mn.WAina:e, W1 I OML
PH 414.214.0444 PAX 414.214.8326
Railr' System Load/DeBection T'estW
Test Type
Horizontal Load to 365 lbs per
ASTM E985 per section 7.1.5
Submitted
BT.
KGB
Submitted
On.
10/06/ IS
Test Focus (Part #a):
48" Long GR2457HCB-1 0, 1/2" Laminated with SGP Interlayer, PGIS050, PG2475
Railing Type:
Shoe molding, 4 panel grips, with glass and unsupported sides
Railing Specifications:
42" (TOR) No caprail. 12" C-C hole locations
Test Method:
3651bf load per ASTM standards
Test Specifications per ASTM E985
Results
System Calculations
Load bs
Displacement (in.)
Midtail Left
Left 2
Test Av g'
Pre Load
180 (lbsf)
Preload
0.548
0.677
0.664
0.6297
Released Test Load
90 (Ibsf)
RTL
0
0
0
0.0000
150
0.362
0.472
0.271
0.3683
Ultimate Test Load
365 (lbst)
200
0.669
1
0.844
0.7933
250
0.984
1.288
1.257
1.1763
Deflection Specifications Per ASTM E985
300
1.319
1.642
1.631
1.5307
Max Mid Deflection
(h/24)+(1/96) = 2.25 in
UTL
1.709
Z145
1 2.12
1.9913
Max Left Deflection
(h/12) = 35 in
RD
0.107
0.07
0.073
0.0833
Residual Deflection
(At RTL)
20% of MD = 0.45 in
Notes
Midrail at 0 lbf =4.1
Potentiometer cannot be zeroed, so calculations are done manually
Shoe mounted to steel
Conclusions
Rail meets ASTM Standard for Max. Allowed Deflection for Mid
Rail meets ASTM Standard for Residual Deflection
Rail meets ASTM Standard for Max. Allowed Deflection for Left 1
Rail meets ASTM Standard for Max. Allowed Deflection for Left 2
Horizontal Load Test- F=n # EF.03.007.HRZ.R1
a' 0.5000
Load (Ibsf)
TEST PHOTOS
Initial Setup: Mid
Preload of 180 lbsf
Actual Deflection of 0.548 in Release Test Load of 90 lbsf
Ultimate Test Load of 365 lbsf
Actual Deflection of 1.709 in
Initial Setup: Left 1
Residual Deflection at 90 lbsf
Actual Deflection of 0.107 in
Preload of 180 lbsf
Actual Deflection of 0.677 in
Release Test Load of 90 lbsf
Ultimate Test Load of 365 lbsf
Actual Deflection of 2.145 in
Residual Deflection at 90 lbsf
Actual Deflection of 0.07 in
Initial Setup: Left
Preload of 180 lbsf
Actual Deflection of 0.664 in
Release Test Load of 90 lbsf
Ultimate Test Load of 365 lbsf
Actual Deflection of 2.12 in
Residual Deflection at 90 lbsf
Actual Deflection of 0.073 in
IT'S I 77
88 99 3 P. �'^4 A
„-
PO BOX 423 I BUTLER. WI 1 53007
10600 W BAo DexRRo I M WAUICYe. W 1 332tA
PH 414. 214.0444 FAX 414.214. 8326
Raxnfr System Load/DeBectton Tesdn
Test Type
Horizontal Load to 365 Is per
ASTM 985 per section 7.1.5
Submitted
By.
KGB
Submitted
Cm.
10/06/15
Test Focus (Part #s):
48" Long GR2457HCB-10,1/2" Laminated with SGP Interlayer, PGIS050, PG2475
Railing Type:
Shoe molding, 4 panel grips, with glass and unsupported sides
Railing Specifications:
42" (TOR) No captaiL 12" C-C hole locations
Test Method:
3651bf load per ASTM standards
Test Specifications per ASTM E985
Results
System Calculations
Load (lbs�
Displacement
Midrail
(in.)
Left Left 2
Test
AVG
Pie Load
180 (Ibsf)
Preload
0.549
0.734
0.756
0.6797
Released Test Load
90 (Ibs f)
RTL
0
0
0
0.0000
150
0.376
0.492
0.499
0.45566667
Ultimate Test Load
365 (lbsl)
200
0.687
1
0.942
0.8337
250
1.027
1.312
1375
1.2380
Deflection Specifications Per ASTM E985
300
1.346
1.754
1.795
1.6317
Max Mid Deflection
(h/24)+(1/96) = 22S in
UTL
1.785
1 2.299
1 2347
2-1437
Max Left Deflection
(h/12) = 35 in
RD
0.045
1 0.005
1 0.029
0.0263
Residual Deflection
(At RTL)
20% of MD = 0.45 in
Notes
Mtdrail at 0lbf = 438 in
Potentiometer cannot be zeroed, so calculations are done manually
Shoe mounted to steel
Conclusions
Rail meets ASTM Standard for Max. Allowed Deflection for Mid
Rail meets ASTM Standard for Residual Deflection
Rail meets ASTM Standard for Max. Allowed Deflection for Left 1
Rail meets ASTM Standard for Max. Allowed Deflection for Left 2
Horizontal toad Test -Fo® # EF.03.007.1-MA1
2.5000
a 2.0000
1 2 3 4 5 6 7
Load pbsf7
TEST PHOTOS
Initial Setup: Mid
Pteload of 1801bsf
Actual Deflection of 0.549 in
Ultimate Test Load of 365 lbsf
Actual Deflection of 1.785 in
Release Test Load of 90 lbsf
Residual Deflection at 90 lbsf
Actual Deflection of 0.045 in
Initial Setup: Left 1
Z
. _ k p 4 :zM ✓fix by % yv
4 fri\ S4 a
>
q
1e
f
� t
im
rm� T
Preload of 180 lbsf
Actual Deflection of 0.734 in
Ultimate Test Load of 365 lbsf
Actual Deflection of 2.299 in
Release Test Load of 90 lbsf
Initial Setup: Left
Preload of 180 lbsf
Actual Deflection of 0.756 in
Release Test Load of 90 lbsf
Ultimate Test Load of 365 Ibsf
Actual Deflection of 2.347 in
Residual Deflection at 90lbsf
Actual Deflection of 0.029 in