HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: MARSHALL
Builder Name: GENTILE CORP.
SCANNED
Street: 1806 N 47tH STREET
Permit Office: ST. LUCIE COUNTY
�
Y
City, State, Zip: FT. PIERCE, FL,
Permit Number.
®®®
S�, Lucie/s
-Owner.-- RICKY MARSHALL
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate
Zone 2 )
rJ New construction or existing New (From Plans)
9. Wall Types (1040.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1040.00 ft'
b. N/A
R= ft'
63. Number of units, if multiple family 1
c. NIA
R= ft'
4. Number of Bedrooms 0
d. NIA
R= ft'
5. Is this a worst case? No
10. Ceiling Types (1000.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1000.00 ft a
6. Conditioned floor area above grade (W) 1000
b. N/A
R= ft.
Conditioned floor area below grade (It') 0
c. N/A
R= ft.
11. Ducts
R ft'
7. Windows(44.0 sqft-) Description Area
a. Sup: Attic, Rat: Attic, AH: A/C
6 150
a. U-Factor: Dbl, U=0.65 44.00 ft'
SHGC: SHGC=0.25
b. U-Factor: NIA ft'
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
18.0 SEER:16.00
c. U-Factor: N/A ft
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: WA ft'
a. Electric Strip Heat
17.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 2.000 ft.
Area Weighted Average SHGC: 0.250
14. Hot water systems
a. Electric
Cap: 50 gallons
S. Floor Types (1000.0 sqft.) Insulation Area
EF: 0.950
a. Slab -On -Grade Edge Insulation R=0.0 1000.00 @'
b. Conservation features
b. N/A R= ft'
None
c. N/A R= ft'
15. Credits
Pstat
Total Proposed Modified Loads: 32.67
Glass/Floor Area: 0.044
PASS
Total Baseline Loads: 33.22
I hereby certify that the plans and specifications covered by
Review of the plans and
1U4UE STgl,
this calculation are in compliance with the Florida Energy
specifications covered by this
y� _ A_� ;e0�
Code.
calculation indicates compliance
p�
with the Florida Energy Code.
lti full .+�`•°•. +:}: .``�.``"` 1\ 0
PREPA ED BY:
DATE:
Before construction is completed
this building will be inspected for
compliance with Section 553.908
4
0 - a
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy
G'0 WE
^oAden.
OWNER/AGENT: YbVln F (,^'
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). cop"
F1`�
5/16/2019 10:27 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: MARSHALL
Bedrooms: 0
Address Type:
Street Address
Building Type: User
Conditioned Area: 1000
Lot#
Owner Name: RICKY MARSHALL
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: No
PlatBook:
Builder Name: GENTILE CORP.
Rotate Angle: 0
Street:
1806 N 47tH STREET
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State, Zip:
FT. PIERCE,
Family Type: Single-family
FL,
-New/Existing: New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp Heating
Design Daily Temp
V Design Location
TMY Site 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39 90
70
75 299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1000 8000
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled
Heated
1 BEDROOM #2
186 1488 No 1
1 Yes
Yes
Yes
2 BEDROOM 1
174 1392 No 1
1 Yes
Yes
Yes
3 BATH
66 528 No 0
1 Yes
Yes
Yes
4 LAUNDRY
48 384 No 0
1 Yes
Yes
Yes
5 A/C
18 144 No 0
1 No
Yes
Yes
1. 6 KITCHEN
198 1584 No 0
1 Yes
Yes
Yes
- 7 LIVING ROOM
310 2480 No 2
1 Yes
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
BEDROOM #2 29 ft 0
186 ft'
--
0 1
0
2 Slab -On -Grade Edge Insulatio
BEDROOM 1 27 ft 0
174 ft'
--
0 1
0
3 Slab -On -Grade Edge Insulatio
BATH Eft 0
66 ft'
--
0 1
0
4 Slab -On -Grade Edge Insulatio
LAUNDRY Eft 0
48 ft'
--
0 1
0
5 Slab -On -Grade Edge Insulatio
A/C 1 ft 0
18 ft2
—
0 1
0
6 Slab -On -Grade Edge Insulatio
KITCHEN 29 ft 0
198 ft'
—
0 1
0
7 Slab -On -Grade Edge Insulatio
LIVING ROOM 33 ft 0
310 ft'
0 1
0
5/16/2019 10:27 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
ROOF
/
Roof
Gable
Roof
Red
Solar
SA Emitt
Emitt Deck
Pitch
V
#
Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1
Hip Composition shingles 1054 ft'
0 it'
Medium
Y
0.6
No
0.9
No 0
18.4
ATTIC
-- /
-
-#
V
Type Ventilation
Vent Ratio (1
in) Area
RBS
IRCC
1
Full attic Vented
300
1000 ft'
Y
N
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Vented) BEDROOM #2
30
Blown
186 ft'
0.1
Wood
2
Under Attic (Vented) BEDROOM
30
Blown
174 ft'
0.1
Wood
3
Under Attic (Vented) BATH
30
Blown
66 ft'
0.1
Wood
4
Under Attic (Vented) LAUNDRY
30
Blown
48 ft'
0.1
Wood
5
Under Attic (Vented) A/C
30
Blown
18 ft'
0.1
Wood
6
Under Attic (Vented) KITCHEN
30
Blown
198 ft'
0.1
Wood
7
Under Attic (Vented) LIVING ROOM
30
Blown
310 ft'
0.1
Wood
WALLS
Adjacent
Cavity Width Height
Sheathing Framing Solar Below
S P ace
pA
1
N
Exterior Concrete Block - Int InsBEDROOM #
4.1 1
0 8
0
8.0 ft'
0
0
0.6
0
-2
S
Exterior Concrete Block - Int InsBEDROOM #
4.1 15
0 8
0
120.0 ft'
0
0
0.6
0
3
W
Exterior Concrete Block - Int InsBEDROOM #
4.1 13
0 8
0
104.0 ft'
0
0
0.6
0
4
N
Exterior Concrete Block - Int InsBEDROOM 1
4.1 14
0 8
0
112.0 ft'
0
0
0.6
0
r- 5
W
Exterior Concrete Block - Int InsBEDROOM 1
4.1 13
0 8
0
104.0 ft'
0
0
0.6
0
6
S
Exterior Concrete Block- Int Insul BATH
4.1 6
0 8
0
48.0 f'
0
0
0.6
0
7
N
Exterior Concrete Block - Int InsuLAUNDRY
4.1 6
0 8
0
48.0 ft'
0
0
0.6
0
8
E
Exterior Concrete Block - Int InsulKITCHEN
4.1 11
0 8
0
88.0 ft'
0
0
0.6
0
9
S
Exterior Concrete Block - Int InsuIKITCHEN
4.1 18
0 8
0
144.0 ft'
0
0
0.6
0
10
N
Exterior Concrete Block - Int InsWVING ROO
4.1 18
0 8
0
144.0 ft'
0
0
0.6
0
11
E
Exterior Concrete Block- Int InsWVING ROO
4.1 15
0 8
0
120.0 ft'
0
0
0.6
0
DOORS
#
Ornt Door Type Space
Storms
U-Value
Width
Height Area
Ft
In
Ft
In
1
W Insulated BEDROOM #
None
.39
3
6
8 20 ft'
2
E Insulated KITCHEN
None
.39
3
6
8 20 ft'
5/16/2019 10:27 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WINDOWS
Orientation shown is the entered, Proposed orientation.
V #
Wall
Ornt ID Frame Panes
NFRC
Overhang
U-Factor SHGC Imp Area Depth Separation
Int Shade
Screening
1
2
3
W 5 Metal Low-E Double Yes
S 9 Metal Low-E Double Yes
E 11 Metal Low-E Double Yes
0.65 0.25 N 15.0 ft' 2 ft 0 in 1 ft 4 in
0.65 0.25 N 9.0 ft' 2 ft 0 in 1 ft 4 in
0.65 0.25 N 20.0 ft' 2 ft 0 in 1 ft 4 in
None
None
None
None
None
None
INFILTRATION
Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000356
933.3 51.24 96.36 .1233 7
HEATING SYSTEM
#
System Type
Subtype
Efficiency Capacity
Block
Ducts
1
Electric Strip Heat/
None
COPA 17 kBtu/hr
1
sys#1
COOLING SYSTEM
—#
System Type
Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1
Central Units
Split
SEER: 16 18 kBtu/hr cfm 0.8 1
sys#1
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt
Conservation
1
Electric None
A/C
0.95 50 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cart # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume.
FEF
None None
fP
DUCTS
/
V #
— Supply —
Location R-Value Area
— Return — Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT
ON RLF
HVAC #
Heat Cool
1
Attic 6 150 ft'
Attic
65 ft' Default Leakage A/C (Default) (Default)
1 1
5/16/2019 10:27 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 4 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
TEMPERATURES
Programablre'Thermostat:
Ceiling Fans:
,]Y
Heating Jan
Feb
rx�
Mar
Apr
May[[
May
Jun
]]
[X] Jul
[[ ]]
(XJ Aug
D(
[
is
j [[r[X��]]
L J Oct
Nov
r[X]] Dee
Venting [ 1 Jan I I
l J l l
Feb
[X Mar
l l
[
LXl Jun
[ ] Jul
(]] Aug
[
Sep
lxl lxl
[ ]Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft'
0 ft
0.3
BEDROOM #2
Default(8 Ibs/sq.ft.
ft'
ft
0.3
BEDROOM 1
Default(B Ibs/sq.ft.
ft'
ft
0.3
BATH
Default(8 lbs/sq.ft.
ft'
ft
0.3
LAUNDRY
Default(81bs/sq.1t.
ft'
ft
0.3
A/C
Default(8 lbs/sq.ft.
ft'
ft
0.3
KITCHEN
Default(8 Ibs/s .ft.
ft2
ft
0.3
LIVING ROOM
5/16/2019 10:27 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: MARSHALL Builder Name: GENTILE CORP.
Street: 1806 N 47tH STREET Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number.
Y
U
Owner: RICKY MARSHALL Jurisdiction:
w
x
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in an dropped ceilin /soffit
y pp 9
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the tap of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be airtight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
Pxtp.nd behind oinong and wiring
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electdcal/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers I
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
blabuepin fire anr'nkler cover plates and walls or ceilings
a. in addition, mspecoon or cog waus snau oe in accordance with the provisions of ICC-400.
5/16/2019 10:27 AM EnergyGaugeS USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1