Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: MARSHALL Builder Name: GENTILE CORP. SCANNED Street: 1806 N 47tH STREET Permit Office: ST. LUCIE COUNTY � Y City, State, Zip: FT. PIERCE, FL, Permit Number. ®®® S�, Lucie/s -Owner.-- RICKY MARSHALL Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) rJ New construction or existing New (From Plans) 9. Wall Types (1040.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1040.00 ft' b. N/A R= ft' 63. Number of units, if multiple family 1 c. NIA R= ft' 4. Number of Bedrooms 0 d. NIA R= ft' 5. Is this a worst case? No 10. Ceiling Types (1000.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1000.00 ft a 6. Conditioned floor area above grade (W) 1000 b. N/A R= ft. Conditioned floor area below grade (It') 0 c. N/A R= ft. 11. Ducts R ft' 7. Windows(44.0 sqft-) Description Area a. Sup: Attic, Rat: Attic, AH: A/C 6 150 a. U-Factor: Dbl, U=0.65 44.00 ft' SHGC: SHGC=0.25 b. U-Factor: NIA ft' 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 18.0 SEER:16.00 c. U-Factor: N/A ft SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: WA ft' a. Electric Strip Heat 17.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems a. Electric Cap: 50 gallons S. Floor Types (1000.0 sqft.) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 1000.00 @' b. Conservation features b. N/A R= ft' None c. N/A R= ft' 15. Credits Pstat Total Proposed Modified Loads: 32.67 Glass/Floor Area: 0.044 PASS Total Baseline Loads: 33.22 I hereby certify that the plans and specifications covered by Review of the plans and 1U4UE STgl, this calculation are in compliance with the Florida Energy specifications covered by this y� _ A_� ;e0� Code. calculation indicates compliance p� with the Florida Energy Code. lti full .+�`•°•. +:}: .``�.``"` 1\ 0 PREPA ED BY: DATE: Before construction is completed this building will be inspected for compliance with Section 553.908 4 0 - a I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy G'0 WE ^oAden. OWNER/AGENT: YbVln F (,^' BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). cop" F1`� 5/16/2019 10:27 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: MARSHALL Bedrooms: 0 Address Type: Street Address Building Type: User Conditioned Area: 1000 Lot# Owner Name: RICKY MARSHALL Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: GENTILE CORP. Rotate Angle: 0 Street: 1806 N 47tH STREET Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, -New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1000 8000 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM #2 186 1488 No 1 1 Yes Yes Yes 2 BEDROOM 1 174 1392 No 1 1 Yes Yes Yes 3 BATH 66 528 No 0 1 Yes Yes Yes 4 LAUNDRY 48 384 No 0 1 Yes Yes Yes 5 A/C 18 144 No 0 1 No Yes Yes 1. 6 KITCHEN 198 1584 No 0 1 Yes Yes Yes - 7 LIVING ROOM 310 2480 No 2 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM #2 29 ft 0 186 ft' -- 0 1 0 2 Slab -On -Grade Edge Insulatio BEDROOM 1 27 ft 0 174 ft' -- 0 1 0 3 Slab -On -Grade Edge Insulatio BATH Eft 0 66 ft' -- 0 1 0 4 Slab -On -Grade Edge Insulatio LAUNDRY Eft 0 48 ft' -- 0 1 0 5 Slab -On -Grade Edge Insulatio A/C 1 ft 0 18 ft2 — 0 1 0 6 Slab -On -Grade Edge Insulatio KITCHEN 29 ft 0 198 ft' — 0 1 0 7 Slab -On -Grade Edge Insulatio LIVING ROOM 33 ft 0 310 ft' 0 1 0 5/16/2019 10:27 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1054 ft' 0 it' Medium Y 0.6 No 0.9 No 0 18.4 ATTIC -- / - -# V Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1000 ft' Y N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM #2 30 Blown 186 ft' 0.1 Wood 2 Under Attic (Vented) BEDROOM 30 Blown 174 ft' 0.1 Wood 3 Under Attic (Vented) BATH 30 Blown 66 ft' 0.1 Wood 4 Under Attic (Vented) LAUNDRY 30 Blown 48 ft' 0.1 Wood 5 Under Attic (Vented) A/C 30 Blown 18 ft' 0.1 Wood 6 Under Attic (Vented) KITCHEN 30 Blown 198 ft' 0.1 Wood 7 Under Attic (Vented) LIVING ROOM 30 Blown 310 ft' 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below S P ace pA 1 N Exterior Concrete Block - Int InsBEDROOM # 4.1 1 0 8 0 8.0 ft' 0 0 0.6 0 -2 S Exterior Concrete Block - Int InsBEDROOM # 4.1 15 0 8 0 120.0 ft' 0 0 0.6 0 3 W Exterior Concrete Block - Int InsBEDROOM # 4.1 13 0 8 0 104.0 ft' 0 0 0.6 0 4 N Exterior Concrete Block - Int InsBEDROOM 1 4.1 14 0 8 0 112.0 ft' 0 0 0.6 0 r- 5 W Exterior Concrete Block - Int InsBEDROOM 1 4.1 13 0 8 0 104.0 ft' 0 0 0.6 0 6 S Exterior Concrete Block- Int Insul BATH 4.1 6 0 8 0 48.0 f' 0 0 0.6 0 7 N Exterior Concrete Block - Int InsuLAUNDRY 4.1 6 0 8 0 48.0 ft' 0 0 0.6 0 8 E Exterior Concrete Block - Int InsulKITCHEN 4.1 11 0 8 0 88.0 ft' 0 0 0.6 0 9 S Exterior Concrete Block - Int InsuIKITCHEN 4.1 18 0 8 0 144.0 ft' 0 0 0.6 0 10 N Exterior Concrete Block - Int InsWVING ROO 4.1 18 0 8 0 144.0 ft' 0 0 0.6 0 11 E Exterior Concrete Block- Int InsWVING ROO 4.1 15 0 8 0 120.0 ft' 0 0 0.6 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 W Insulated BEDROOM # None .39 3 6 8 20 ft' 2 E Insulated KITCHEN None .39 3 6 8 20 ft' 5/16/2019 10:27 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WINDOWS Orientation shown is the entered, Proposed orientation. V # Wall Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 2 3 W 5 Metal Low-E Double Yes S 9 Metal Low-E Double Yes E 11 Metal Low-E Double Yes 0.65 0.25 N 15.0 ft' 2 ft 0 in 1 ft 4 in 0.65 0.25 N 9.0 ft' 2 ft 0 in 1 ft 4 in 0.65 0.25 N 20.0 ft' 2 ft 0 in 1 ft 4 in None None None None None None INFILTRATION Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 933.3 51.24 96.36 .1233 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPA 17 kBtu/hr 1 sys#1 COOLING SYSTEM —# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Units Split SEER: 16 18 kBtu/hr cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None A/C 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector System Model # Collector Model # Area Storage Volume. FEF None None fP DUCTS / V # — Supply — Location R-Value Area — Return — Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT ON RLF HVAC # Heat Cool 1 Attic 6 150 ft' Attic 65 ft' Default Leakage A/C (Default) (Default) 1 1 5/16/2019 10:27 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 4 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programablre'Thermostat: Ceiling Fans: ,]Y Heating Jan Feb rx� Mar Apr May[[ May Jun ]] [X] Jul [[ ]] (XJ Aug D( [ is j [[r[X��]] L J Oct Nov r[X]] Dee Venting [ 1 Jan I I l J l l Feb [X Mar l l [ LXl Jun [ ] Jul (]] Aug [ Sep lxl lxl [ ]Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft' 0 ft 0.3 BEDROOM #2 Default(8 Ibs/sq.ft. ft' ft 0.3 BEDROOM 1 Default(B Ibs/sq.ft. ft' ft 0.3 BATH Default(8 lbs/sq.ft. ft' ft 0.3 LAUNDRY Default(81bs/sq.1t. ft' ft 0.3 A/C Default(8 lbs/sq.ft. ft' ft 0.3 KITCHEN Default(8 Ibs/s .ft. ft2 ft 0.3 LIVING ROOM 5/16/2019 10:27 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: MARSHALL Builder Name: GENTILE CORP. Street: 1806 N 47tH STREET Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number. Y U Owner: RICKY MARSHALL Jurisdiction: w x Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in an dropped ceilin /soffit y pp 9 the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the tap of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall Pxtp.nd behind oinong and wiring Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electdcal/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers I sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids blabuepin fire anr'nkler cover plates and walls or ceilings a. in addition, mspecoon or cog waus snau oe in accordance with the provisions of ICC-400. 5/16/2019 10:27 AM EnergyGaugeS USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1