HomeMy WebLinkAboutREVIEW COMMENTSSir�csdtf (�Osss�r
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL U982
Address:
City / State / Zip:
Parcel #:
Zoning:
80B Osprey Ct
Fort Pierce, FI 34949
1410-502-0343-000/9
HIRD
APPLICATION INFORMATION
Permit Number:
Permit Type:
Contractor Name:
Business Name:
Business Addr:
City / State I Zip:
1907-0149
REVIEW COMMENTS
SC All Nbu
S$° udecolint,
Page 1
Owner(s):
Michael A Chesanek
Jurisdiction: SAINT LUCIE COUNTY
BUILDING RESIDENTIAL RENOVATION
Lot#:
Stories:
Block:
Automatic Sprinkler System? No
Fax Number_- x
Email: kP C.LI e'e �^e,
i
c /MP.ti l
REVIEWS AND COMMENTS
Review Type
Status Reviewed By Date Started Date Completed, Date Released
�s
FRONT COUNTER REVIEW
COMPLETE Audrey Humphrey 7/8/2019 71812019 71812019
Comment
PERMIT ON HOLD
COMPLETE Gary Stepalavich 9124/2619 912412019
Comment:
-.
PLANS EXAMINER REVIEW
INCOMPLETE Jpi, Inc -Andrew 913012019
Comment:
fiff WIND EXPOSURE CATEGORY IS INCORRECT. SITE IS WITHIN 600' OF OPEN WATER IN EXCESS OF
9/26/2019
5,000'. (R301.2.1.4.3) ---
9/26/2019
Comment:
2) KEYNOTES ARE MISSING FROM STAIR DETAIL. ([A] 107.2.1)
9Y26/2019
Comment:
3 REVISE DRAWINGS TO INCLUDE ONE PLAN TO SHOW EXISTING WORK TO BE REMOVED AND ONE
N TO SHOW NEW WORK. ([A] 107.2.1)
Comment:
4) COLUMNS FORTHE DECKARE ON THE SEAWALL. THE SEAWALL IS DIVIDED BY THE PROPERTY LINE.
9/26/2019
OWNERSHIP OF THE SEAWALL IS NOT CLEAR. THE COLUMN CANNOT BE INSTALLED OUT OF THE
PROPERTY LINE OR ON ANOTHER OWNER'S STRUCTURE. PLEASE CLARIFY ([A] 107.2.1)
Comment:
5) INFORMATION IS MISSING FROM PLANS. SHOW FOUNDATION REQUIREMENTS, COLUMN ATTACHMENT
9/2612019
TO FOUNDATION & BEAMS/JOISTS. SHOW ALL CONNECTIONS OF ALL MATERIALS & COMPONENTS. NO \
CONNECTION OF CEMENT AND HARDI BOARD PROVIDED./HARDI BOARD REQUIRES A PRODUCT t 1
PPROVA . ([A] 107.2.1) ���bbb���ddd
9/26/2019
Comment:
��''pp
Comment:
7j STRUCTURAL SYSTEMS OF BUILDINGS AND STRUCTURES SHALL BE DESIGNED, CONNECTED AND
9/26/2019
ANCHORED TO RESIST FLOTATION, COLLAPSE OR PERMANENT LATERAL MOVEMENT DUE TO
STRUCTURAL LOADS AND STRESSES FROM FLOODING EQUAL TO THE DESIGN FLOOD ELEVATION.
(R322.1.2)
9/30/2019
Comment:
8) COMBUSTIBLE STRUCTURE REQUIRES 5' SETBACK FROM ADJOINING SITE. (FBC [A] 101.4.5) SEE FL
FIRE PREVENTION CODE SECTION 27.1 REFERENCE TO NFPA 501A SECTION 6.4.
C("6
"OL 4pr47
qo� - ?`,s4
�'467 -MI6 3 - gos9
11
:4.
\i