Loading...
HomeMy WebLinkAboutCERTIFICATION - DESIGN LOAD COMPLIANCEPlanning & Development Services Department Building & Code Regulations Division T%�® o 2300 Virginia Avenue, Fort Pierce, FL 34982 — 4�2I -53 � Y Certification for Design Load Compliance Project Name: _ 89 AAlfns D Permit#: ig% - 01 /414 Occupancy Type: S ry_ Construction Type: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida 2017 Building Code Fifth Edition with 20 N/A Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open 3. Risk Category., _I X II _III _ IV Exposure Category: _B X C _D 4. Design Wind Velocity 160 mph X ASD _LRFD End Zone Width: 6 ft 5. Mean Roof Height I Z Roof Pitch: B :12 Parapet: N/A ft 6. Components & Gadding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, dearly label on all plan openings): 1-210,O 1r7A.o y O Flyr 9 d Syr y zP.s" Zone 1:— 3/r A Zone 2: ^Si 3 Zone 3: Zane 4: ?lk,G Zone S:^ Ia,. t Garage: 3 7. Design Loads: Floor. 100 PSF Roof/Dead: 12 PSF Roof/Live: 30 Balcony: wA PSF Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings, N/A PSF 8. Were Shear Walls Considered For Structure? Yes Y.NotApplicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certifythet'structural elements depicted on these plans provide adequate resistance to the design forces s " i ie Py.l�ar f�T szoy6. Print Name Cert # & Co. Cert Auth. ^/&Z N(o gnature,Date, ds I. Pdl2� Sd', Ly�[C` FG. 3Y9�/• � f. / Company Name & Address Revised 07 1201