Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: MW-260 Builder Name: GHO HOMES tyV B Y Street: 2974 BENT PINE DRIVE Permit Office: ST LUCIE COUNTY St City, State, Zip: FORT PIERCE, FL, 34951 Permit Number: `% Lucie COUYity Owner: Jurisdiction: Design Location: FL, Fort Pierce County: ST. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types(2523.0 soft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.0 2213.20 ft' b. Frame - Wood, Adjacent R=11.0 309.78 ft- 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types (2451.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=40.0 2451.00ft= 6. Conditioned floor area above grade (112) 2451 b. N/A R= ft' Conditioned floor area below grade (ft2) 0 c. N/A R= ft' 11. Ducts R ft2 7. Windows(433.4 soft.) Description Area a. Sup: Attic, Ret: Attic, AH: Main 6 800 a. U-Factor: Dbl, U=0.53 433.40 ft2 SHGC: SHGC=0.26 b. U-Factor: N/A ft2 12. Cooling systems kBlu/hr Efficiency SHGC: a. Central Unit 60.0 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 29.5 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 0.000 ft. Area Weighted Average SHGC: 0.260 14. Hot water systems a. Electric Cap: 50 gallons 8. FloorT pes 2451.0 sqft.) Insulation Area y ( EF: 0.900 a. Slab -On -Grade Edge Insulation R=0.0 2451.00 ft2 b. Conservation features b. N/A R= ft' None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.177 Total Proposed Modified Loads: 80.62 PASS Total Baseline Loads: 80.90 I hereby certify that the pans pecifications covered by Review of the plans and 4SHE ST9?, this calculation are in ompl in 'th the Florida Energy specifications covered by this ,ye g FO�y Code. calculation indicates compliance "�„ �0� with the Florida Energy Code. Er wu,�%. •:=5r,":.>;;.• PREPARED BY: DATE: 0511711s Before construction is completed this building will be inspected for compliance with Section 553.908 y C 0 ° a I hereby certify that this building, as designed, is in compliance Florida Statutes. COD with the Florida Energy $ode. WE �J OWNER/AGENT: BUILDING OFFICIAL: DATE: a DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checkin nacc r to d 2.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater tha iii. �� " CODE COMPLIANCE STo LUCIE COUNTY fti,, BOCC JpZ 5/16/2019 7:16 PM EnergyGaugeO USA Section R405.4.1 Compliant Software peg �8 ?ft Page 1 of 5 tr(U eccoury�ent FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: MW-260 User 1 GHO HOMES ST LUCIE COUNTY Single-family New (From Plans) Bedrooms: 3 Conditioned Area: 2451 Total Stories: 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: No Whole House Fan: No Address Type: Street Address Lot # Block/Subdivision: PlatBook: Street: 2974 BENT PINE DRIV County: ST. Lucie City, State, Zip: FORT PIERCE, FL, 34951 CLIMATE V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Blockl 2451 22794.3 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfI ID Finished Cooled Heated 1 Main 2451 22794.3 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 223.2 ft 0 2451 ft2 - — - 0 0 1 ROOF / V # Type Roof Gable Roof Materials Area Area Color Solar SA Emitt Emitt Deck Pitch Absor. Tested Tested Insul. (deg) 1 Hip Flat tile/slate 2741 ft2 0 ft2 Medium 0.4 N 0.9 No 0 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 2451 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Free Truss Type 1 Under Attic (Vented) Main 40 Blown 2451 ft2 0.1 Wood 5/16/2019 7:16 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Belo w Space _ 1 N Exterior Concrete Block - Ext Insul Main 4 58 5 9 4 545.2 ft2 0 0 0.3 0 _ 2 NE Extedor Concrete Block - Ext Insul Main 4 8 7 11 4 97.3 ft2 0 0 0.3 0 _ 3 E Exterior Concrete Block - Ext Insul Main 4 63 2 9 4 589.6 ft- 0 0 0.3 0 -4 S Exterior Concrete Block - Ext Insul Main 4 57 8 9 4 538.2 ft2 0 0 0.3 0 5 W Exterior Concrete Block - Ext Insul Main 4 36 2 11 4 409.9 ft- 0 0 0.3 0 _ 6 NW Exterior Concrete Block - Ext Insul Main 4 2 11 11 4 33.1 ft2 0 0 0.3 0 7 - Garage Frame - Wood Main 11 27 4 11 4 309.8 ft2 0 0.25 0.3 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 W Wood Main None .39 6 8 48 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 n 1 Metal Double (Clear) Yes 0.53 0.26 N 20.0 ft2 0 ft 0 in 0 It 0 in None None 2 n 1 Metal Double (Clear) Yes 0.53 0.26 N 7.0 ft2 0 ft 0 in 0 ft 0 in None None 3 n 1 Metal Double (Clear) Yes 0.53 0.26 N 8.0 ft2 0 ft 0 in 0 ft 0 in None None 4 ne 2 Metal Double (Clear) Yes 0.53 0.26 N 20.0 ft' 0 ft 0 in 0 It 0 in None None 5 ne 2 Metal Double (Clear) Yes 0.53 0.26 N 22.5 ft2 0 ft 0 in 0 ft 0 in None None 6 e 3 Metal Double (Clear) Yes 0.53 0.26 N 43.3 ft2 0 ft 0 in 0 ft 0 in None None 7 e 3 Metal Double (Clear) Yes 0.53 0.26 N 111.6 ft2 0 ft 0 in 0 ft 0 in None None 8 e 3 Metal Double (Clear) Yes 0.53 0.26 N 31.6 ft2 0 ft 0 in 0 ft 0 in None None 9 e 3 Metal Double (Clear) Yes 0.53 0.26 N 7.0 ft2 0 ft 0 in 0 110 in None None 10 s 4 Metal Double (Clear) Yes 0.53 0.26 N 20.0 ft' 0 ft 0 in 0 ft 0 in None None 11 6 4 Metal Double (Clear) Yes 0.53 0.26 N 43.3 ft- 0 ft 0 in 0 ft 0 in None None 12 s 4 Metal Double (Clear) Yes 0.53 0.26 N 9.0 ft2 0 ft 0 in 0 ft 0 in None None 13 w 5 Metal Double (Clear) Yes 0.53 0.26 N 48.0 ft2 0 ft 0 in 0 ft 0 in None None 14 w 5 Metal Double (Clear) Yes 0.53 0.26 N 18.0 ft- 0 ft 0 in 0 ft 0 in None None 15 w 5 Metal Double (Clear) Yes 0.59 0.26 N 8.7 ft2 0 ft 0 in 0 ft 0 in None None 16 NW 6 Metal Double (Clear) Yes 0.53 0.26 N 15.3 ft2 - 0 ft 0 in 0 ft 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 902 ft2 902 ft2 64 ft 9.3 ft 1 5/16/2019 7:16 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000325 2089.5 114.71 215.73 .2464 5.5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPA 29.48 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 60 kBtu/hr 1800 cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Main 0.9 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft' DUCTS / --Supply--- V # Location R-Value Area --- Return -- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC# Heat Cool 1 Attic 6 800 ft' Attic 685 ft' Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Jan Feb Mar Venting Jen FDec eb lX Mar Ceiling Fans:Cooling May r jX� [ ] rX� rjX,j Novr[X�] f JC� Apr [ May ri Jun E) Jul Ix] Aug [ 1 Sep Oct [X] Nov Jun 1 Jul l 1 Aug I) Sep [ ] Dec 5/16/2019 7:16 PM EgergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68. 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft' 0 ft 0.3 Main Name: Signature: Rating Compant: Date: 5/16/2019 7:16 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 5 of 5 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX" = 100 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 60.0 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned Floor area (sq. ft.) 6. 2451 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.530 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.260 c) Area - 7c. 433.4 8. Skylights a) U-faclor:(weighted average) Be. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 9a. 0.0 9b. 9c. 10A1. 10A2. 4.0 14. Heating system: Capacity 29.5 a) Split system heat pump HSPF b) Single package heat pump HSPF c) Electric resistance COP 1.0 d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE f) Other 15. Water heating system a) Electric resistance EF 0.90 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF_ f) Heat recovery unit HeatRec% g) Other 10B1. 11.0 10132. 16. HVAC credits claimed (Performance Method) a) Ceiling fans 11a. 40.0 b) Cross ventilation No 11b. c) Whole house fan No 11c. d) Multizone cooling credit 11d. No e) Multizone heating credit f) Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied wijh the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed r exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based o installed code compliant, features. Builder Address of New Home: Date: :5 Z11' City/FL Zip: FORT PIERCE FL 34951 5/16/2019 7:17:05 PM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 wrightsoft° Load Short Form Entire House Project Information For: MW-260 2974 BENT PINE DRIVE, FORT PIERCE, FL 34951 Htg Clg Outsidedb (°F) 43 90 Method Inside db (°F) 70 72 Construction quality Design TD (°F) 27 18 Fireplaces Daily range - L Inside humidity (%) 30 50 Moisture difference (gr/lb) 0 68 Job: Date: May 13, 2019 By: Infiltration Simplified Tight 0 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Lennox Trade Trade 14ACX SERIES Model Cond 14ACX-059-230-04 AHRI ref Coil CBX27UH-060-230'++TDR AHRI ref 5053119 Efficiency 100 EFF Efficiency 12.2 EER, 15 SEER Heating input 8.6 kW Sensible cooling 39550 Btuh Heating output 29480 Btuh Latent cooling 16950 Btuh Temperature rise 14 °F Total cooling 56500 Btuh Actual air flow 1883 cfm Actual air flow 1883 cfm Air flow factor 0.056 cfm/Btuh Air flow factor 0.049 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.72 ROOM NAME Area (ft') Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) MASTER SUITE 370 5911 5885 330 287 HER WIC 87 1265 733 71 36 HIS WIC 44 39 229 2 11 GREAT ROOM 506 5641 7159 315 349 DINING 187 3287 5917 183 288 FOYER 75 1763 2489 98 121 NOOK 139 2607 3391 145 165 KIT 164 143 1982 8 97 BED 3 149 1623 1931 91 94 BED3WIC 33 1081 621 60 30 CABANA 76 2129 1499 119 73 BED 2 188 1871 2056 104 100 BATH 2 59 1047 642 58 31 UTILITY 49 109 695 6 34 MECH 36 467 632 26 31 7Cr1C ZCC 'IZ7 1WFAi MyG�s�����r GVC Yr/V GVVJ Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri ht5oft° z010-May-1616d Page 9 Rig R5U02818 PageI �r� CAUsersUasonTomments\Wrightsoft 1-1VACNW-260.mp Calc=MJ8 Front Door faces: W Entire House 2451 33758 38663 1883 1883 Other equip loads 0 0 Equip. @ 0.95 RSM 36730 Latent cooling 14935 T/ A, C I I I 1 I A00] V II'1LJ 4101 JJ/JV JIVVV IVOJ IVVJ Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. C wri ht5OfC 2019-May-1618:10:e2 �% RighiSuile®Univ ersa1201212.1.05 RSU0281B Paget C:\Usem\Jason\Documents\Wrightsoft HVACVVV-260.mp Calc=MJ8 Front Door faces: W F wrightsoftProject Summary Entire House For: MW-260 2974 BENT PINE DRIVE, FORT PIERCE, FL 34951 Notes: Job: Date: May 13, 2019 By: Design In Weather: Vero Beach, FL, US Winter Design Conditions Summer Design Conditions Outside db 43 OF Outside db 90 OF Inside db 70 OF Inside db 72 OF Design TD 27 OF Design TO 18 OF Daily range L Relative humidity 50 % Moisture difference 68 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 27129 Btuh Structure 30527 Btuh Ducts 6630 Btuh Ducts 8135 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 33758 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 36730 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Tight Fireplaces 0 Structure 12254 Btuh Ducts 2682 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (fta) 2451 2451 Equipment latent load 14935 Btuh Volume (W) 25014 25014 Air changes/hour 0.11 0.06 Equipment total load 51665 Btuh Equiv. AVF (cfm) 46 25 Req. total capacity at 0.70 SHR 4.4 ton Heating Equipment Summary Cooling Equipment Summary Make Make Lennox Trade Trade 14ACX SERIES Model Cond 14ACX-059-230-04 AHRI ref Coil CBX27UH-060-230'++TDR AHRI ref 5053119 Efficiency 100 EFF Efficiency 12.2 EER, 15 SEER Heating input 8.6 kW Sensible cooling 39550 Btuh Heating output 29480 Btuh Latent cooling 16950 Btuh Temperature rise 14 OF Total cooling 56500 Btuh Actual air flow 1883 cfm Actual air flow 1883 cfm Air flow factor 0.056 cfm/Btuh Air flow factor 0.049 cfm1Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.72 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrlghtSOft' RightSuile® Universal 201212.1.05 RSUD2818 2019-May-161 Page 1 rM CAusersVason\Documents\Wrightsof AVAC1MW-260.rup Cale =MJ8 Front Door faces: W GHO HOMES MW-260 2974 BENT PINE DRIVE FORT PIERCE, FL 54951