HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: MW-260
Builder Name: GHO HOMES
tyV
B Y
Street: 2974 BENT PINE DRIVE
Permit Office: ST LUCIE COUNTY
St
City, State, Zip: FORT PIERCE, FL, 34951
Permit Number:
`% Lucie COUYity
Owner:
Jurisdiction:
Design Location: FL, Fort Pierce
County: ST. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types(2523.0 soft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.0 2213.20 ft'
b. Frame - Wood, Adjacent
R=11.0 309.78 ft-
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
10. Ceiling Types (2451.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Under Attic (Vented)
R=40.0 2451.00ft=
6. Conditioned floor area above grade (112) 2451
b. N/A
R= ft'
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft'
11. Ducts
R ft2
7. Windows(433.4 soft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Main
6 800
a. U-Factor: Dbl, U=0.53 433.40 ft2
SHGC: SHGC=0.26
b. U-Factor: N/A ft2
12. Cooling systems
kBlu/hr Efficiency
SHGC:
a. Central Unit
60.0 SEER:15.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Strip Heat
29.5 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 0.000 ft.
Area Weighted Average SHGC: 0.260
14. Hot water systems
a. Electric
Cap: 50 gallons
8. FloorT pes 2451.0 sqft.) Insulation Area
y (
EF: 0.900
a. Slab -On -Grade Edge Insulation R=0.0 2451.00 ft2
b. Conservation features
b. N/A R= ft'
None
c. N/A R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.177 Total Proposed Modified Loads: 80.62
PASS
Total Baseline
Loads: 80.90
I hereby certify that the pans pecifications covered by
Review of the plans and
4SHE ST9?,
this calculation are in ompl in 'th the Florida Energy
specifications covered by this
,ye g FO�y
Code.
calculation indicates compliance
"�„ �0�
with the Florida Energy Code.
Er wu,�%. •:=5r,":.>;;.•
PREPARED BY:
DATE: 0511711s
Before construction is completed
this building will be inspected for
compliance with Section 553.908
y C
0
° a
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
COD
with the Florida Energy $ode.
WE �J
OWNER/AGENT:
BUILDING OFFICIAL:
DATE: a
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checkin nacc r to d 2.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater tha iii. �� "
CODE COMPLIANCE
STo LUCIE COUNTY fti,,
BOCC JpZ
5/16/2019 7:16 PM EnergyGaugeO USA Section R405.4.1 Compliant Software peg �8 ?ft Page 1 of 5
tr(U eccoury�ent
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
MW-260
User
1
GHO HOMES
ST LUCIE COUNTY
Single-family
New (From Plans)
Bedrooms: 3
Conditioned Area: 2451
Total Stories: 1
Worst Case: No
Rotate Angle: 0
Cross Ventilation: No
Whole House Fan: No
Address Type: Street Address
Lot #
Block/Subdivision:
PlatBook:
Street: 2974 BENT PINE DRIV
County: ST. Lucie
City, State, Zip: FORT PIERCE,
FL, 34951
CLIMATE
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90
70 75 299 62 Low
BLOCKS
Number
Name
Area Volume
1
Blockl
2451 22794.3
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfI ID Finished Cooled Heated
1
Main
2451 22794.3 Yes 4
3 1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 223.2 ft 0
2451 ft2 - — - 0 0 1
ROOF
/
V #
Type
Roof Gable Roof
Materials Area Area Color
Solar SA Emitt Emitt Deck Pitch
Absor. Tested Tested Insul. (deg)
1
Hip
Flat tile/slate 2741 ft2 0 ft2 Medium
0.4 N 0.9 No 0 26.6
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 150 2451 ft2 N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Free Truss Type
1
Under Attic (Vented)
Main 40 Blown
2451 ft2 0.1 Wood
5/16/2019 7:16 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity Width Height
Sheathing Framing Solar
Belo w
Space
_ 1
N
Exterior
Concrete Block - Ext Insul
Main
4 58
5 9
4
545.2 ft2
0
0
0.3
0
_ 2
NE
Extedor
Concrete Block - Ext Insul
Main
4 8
7 11
4
97.3 ft2
0
0
0.3
0
_ 3
E
Exterior
Concrete Block - Ext Insul
Main
4 63
2 9
4
589.6 ft-
0
0
0.3
0
-4
S
Exterior
Concrete Block - Ext Insul
Main
4 57
8 9
4
538.2 ft2
0
0
0.3
0
5
W
Exterior
Concrete Block - Ext Insul
Main
4 36
2 11
4
409.9 ft-
0
0
0.3
0
_ 6
NW
Exterior
Concrete Block - Ext Insul
Main
4 2
11 11
4
33.1 ft2
0
0
0.3
0
7
-
Garage
Frame - Wood
Main
11 27
4 11
4
309.8 ft2
0
0.25
0.3
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
W
Wood Main
None
.39
6
8
48 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
V
#
Ornt ID
Frame
Panes NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
n 1
Metal
Double (Clear)
Yes
0.53 0.26
N
20.0 ft2
0 ft 0 in
0 It 0 in
None
None
2
n 1
Metal
Double (Clear)
Yes
0.53 0.26
N
7.0 ft2
0 ft 0 in
0 ft 0 in
None
None
3
n 1
Metal
Double (Clear)
Yes
0.53 0.26
N
8.0 ft2
0 ft 0 in
0 ft 0 in
None
None
4
ne 2
Metal
Double (Clear)
Yes
0.53 0.26
N
20.0 ft'
0 ft 0 in
0 It 0 in
None
None
5
ne 2
Metal
Double (Clear)
Yes
0.53 0.26
N
22.5 ft2
0 ft 0 in
0 ft 0 in
None
None
6
e 3
Metal
Double (Clear)
Yes
0.53 0.26
N
43.3 ft2
0 ft 0 in
0 ft 0 in
None
None
7
e 3
Metal
Double (Clear)
Yes
0.53 0.26
N
111.6 ft2
0 ft 0 in
0 ft 0 in
None
None
8
e 3
Metal
Double (Clear)
Yes
0.53 0.26
N
31.6 ft2
0 ft 0 in
0 ft 0 in
None
None
9
e 3
Metal
Double (Clear)
Yes
0.53 0.26
N
7.0 ft2
0 ft 0 in
0 110 in
None
None
10
s 4
Metal
Double (Clear)
Yes
0.53 0.26
N
20.0 ft'
0 ft 0 in
0 ft 0 in
None
None
11
6 4
Metal
Double (Clear)
Yes
0.53 0.26
N
43.3 ft-
0 ft 0 in
0 ft 0 in
None
None
12
s 4
Metal
Double (Clear)
Yes
0.53 0.26
N
9.0 ft2
0 ft 0 in
0 ft 0 in
None
None
13
w 5
Metal
Double (Clear)
Yes
0.53 0.26
N
48.0 ft2
0 ft 0 in
0 ft 0 in
None
None
14
w 5
Metal
Double (Clear)
Yes
0.53 0.26
N
18.0 ft-
0 ft 0 in
0 ft 0 in
None
None
15
w 5
Metal
Double (Clear)
Yes
0.59 0.26
N
8.7 ft2
0 ft 0 in
0 ft 0 in
None
None
16
NW 6
Metal
Double (Clear)
Yes
0.53 0.26
N
15.3 ft2 - 0 ft 0 in
0 ft 0 in
None
None
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
902 ft2
902 ft2
64 ft
9.3 ft
1
5/16/2019 7:16 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 3 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000325
2089.5 114.71 215.73 .2464 5.5
HEATING SYSTEM
# System Type
Subtype
Efficiency Capacity Block
Ducts
1 Electric Strip Heat/
None
COPA 29.48 kBtu/hr 1
sys#1
COOLING SYSTEM
# System Type
Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1 Central Unit/
Split
SEER: 15 60 kBtu/hr 1800 cfm 0.7 1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap Use SetPnt Conservation
1 Electric None
Main
0.9 50 gal 62.3 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cart # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None None
ft'
DUCTS
/ --Supply---
V # Location R-Value Area
--- Return -- Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT QN RLF
HVAC#
Heat Cool
1 Attic 6 800 ft'
Attic
685 ft' Default Leakage Main (Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Jan Feb Mar
Venting Jen FDec
eb lX Mar
Ceiling Fans:Cooling
May
r jX� [ ] rX� rjX,j Novr[X�]
f JC� Apr [ May ri Jun E) Jul Ix] Aug [ 1 Sep Oct [X] Nov
Jun 1 Jul l 1 Aug I) Sep
[ ] Dec
5/16/2019 7:16 PM EgergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
Thermostat Schedule:
HERS 2006
Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68.
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture
Fraction
Space
Default 8 Ibs/s
.ft.
0 ft'
0 ft
0.3
Main
Name: Signature:
Rating Compant: Date:
5/16/2019 7:16 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 5 of 5
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX" = 100
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level
a) Supply ducts R 6.0
2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0
c) AHU location Attic/Attic
3. No. of units (if multiple -family) 3. 1
4. Number of bedrooms 4. 3 13. Cooling system: Capacity 60.0
a) Split system SEER 15.0
5. Is this a worst case? (yes/no) 5. No b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned Floor area (sq. ft.) 6. 2451 d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average) 7a. 0.530
b) Solar Heat Gain Coefficient (SHGC) 7b. 0.260
c) Area - 7c. 433.4
8. Skylights
a) U-faclor:(weighted average) Be. NA
b) Solar Heat Gain Coefficient (SHGC) 8b. NA
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
b) Wood, raised (R-value)
c) Concrete, raised (R-value)
10. Wall type and insulation:
A. Exterior:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
B. Adjacent:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
11. Ceiling type and insulation level
a) Under attic
b) Single assembly
c) Knee walls/skylight walls
d) Radiant barrier installed
9a. 0.0
9b.
9c.
10A1.
10A2. 4.0
14. Heating system: Capacity 29.5
a) Split system heat pump HSPF
b) Single package heat pump HSPF
c) Electric resistance COP 1.0
d) Gas furnace, natural gas AFUE
e) Gas furnace, LPG AFUE
f) Other
15. Water heating system
a) Electric resistance EF 0.90
b) Gas fired, natural gas EF
c) Gas fired, LPG EF
d) Solar system with tank EF
e) Dedicated heat pump with tank EF_
f) Heat recovery unit HeatRec%
g) Other
10B1. 11.0
10132.
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
11a. 40.0
b) Cross ventilation No
11b.
c) Whole house fan No
11c.
d) Multizone cooling credit
11d. No
e) Multizone heating credit
f) Programmable thermostat Yes
'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied wijh the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed r exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based o installed code compliant, features.
Builder
Address of New Home:
Date: :5 Z11'
City/FL Zip: FORT PIERCE FL 34951
5/16/2019 7:17:05 PM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
wrightsoft° Load Short Form
Entire House
Project Information
For: MW-260
2974 BENT PINE DRIVE, FORT PIERCE, FL 34951
Htg Clg
Outsidedb (°F)
43
90 Method
Inside db (°F)
70
72 Construction quality
Design TD (°F)
27
18 Fireplaces
Daily range
-
L
Inside humidity (%)
30
50
Moisture difference (gr/lb)
0
68
Job:
Date: May 13, 2019
By:
Infiltration
Simplified
Tight
0
HEATING EQUIPMENT
COOLING EQUIPMENT
Make
Make Lennox
Trade
Trade 14ACX SERIES
Model
Cond 14ACX-059-230-04
AHRI ref
Coil CBX27UH-060-230'++TDR
AHRI ref 5053119
Efficiency
100 EFF
Efficiency 12.2 EER, 15 SEER
Heating input
8.6
kW
Sensible cooling 39550
Btuh
Heating output
29480
Btuh
Latent cooling 16950
Btuh
Temperature rise
14
°F
Total cooling 56500
Btuh
Actual air flow
1883
cfm
Actual air flow 1883
cfm
Air flow factor
0.056
cfm/Btuh
Air flow factor 0.049
cfm/Btuh
Static pressure
0
in H2O
Static pressure 0
in H2O
Space thermostat
Load sensible heat ratio 0.72
ROOM NAME
Area
(ft')
Htg load
(Btuh)
Clg load
(Btuh)
Htg AVF
(cfm)
Clg AVF
(cfm)
MASTER SUITE
370
5911
5885
330
287
HER WIC
87
1265
733
71
36
HIS WIC
44
39
229
2
11
GREAT ROOM
506
5641
7159
315
349
DINING
187
3287
5917
183
288
FOYER
75
1763
2489
98
121
NOOK
139
2607
3391
145
165
KIT
164
143
1982
8
97
BED 3
149
1623
1931
91
94
BED3WIC
33
1081
621
60
30
CABANA
76
2129
1499
119
73
BED 2
188
1871
2056
104
100
BATH 2
59
1047
642
58
31
UTILITY
49
109
695
6
34
MECH
36
467
632
26
31
7Cr1C
ZCC
'IZ7
1WFAi MyG�s�����r
GVC Yr/V GVVJ
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wri ht5oft° z010-May-1616d Page
9 Rig R5U02818 PageI
�r� CAUsersUasonTomments\Wrightsoft 1-1VACNW-260.mp Calc=MJ8 Front Door faces: W
Entire House
2451
33758
38663
1883
1883
Other equip loads
0
0
Equip. @ 0.95 RSM
36730
Latent cooling
14935
T/ A, C
I
I
I 1
I A00]
V II'1LJ 4101 JJ/JV JIVVV IVOJ IVVJ
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
C wri ht5OfC 2019-May-1618:10:e2
�% RighiSuile®Univ ersa1201212.1.05 RSU0281B Paget
C:\Usem\Jason\Documents\Wrightsoft HVACVVV-260.mp Calc=MJ8 Front Door faces: W
F wrightsoftProject Summary
Entire House
For: MW-260
2974 BENT PINE DRIVE, FORT PIERCE, FL 34951
Notes:
Job:
Date: May 13, 2019
By:
Design In
Weather: Vero Beach, FL, US
Winter Design Conditions
Summer Design Conditions
Outside db 43 OF
Outside db
90
OF
Inside db 70 OF
Inside db
72
OF
Design TD 27 OF
Design TO
18
OF
Daily range
L
Relative humidity
50
%
Moisture difference
68
gr/lb
Heating Summary
Sensible Cooling Equipment Load Sizing
Structure 27129 Btuh
Structure
30527
Btuh
Ducts 6630 Btuh
Ducts
8135
Btuh
Central vent (0 cfm) 0 Btuh
Central vent (0 cfm)
0
Btuh
Humidification 0 Btuh
Blower
0
Btuh
Piping 0 Btuh
Equipment load 33758 Btuh
Use manufacturer's data
n
Rate/swing multiplier
0.95
Infiltration
Equipment sensible load
36730
Btuh
Method Simplified
Latent Cooling Equipment Load Sizing
Construction quality Tight
Fireplaces 0
Structure
12254
Btuh
Ducts
2682
Btuh
Heating Cooling
Central vent (0 cfm)
0
Btuh
Area (fta) 2451 2451
Equipment latent load
14935
Btuh
Volume (W) 25014 25014
Air changes/hour 0.11 0.06
Equipment total load
51665
Btuh
Equiv. AVF (cfm) 46 25
Req. total capacity at 0.70 SHR
4.4
ton
Heating Equipment Summary Cooling Equipment Summary
Make
Make Lennox
Trade
Trade 14ACX SERIES
Model
Cond 14ACX-059-230-04
AHRI ref
Coil CBX27UH-060-230'++TDR
AHRI ref 5053119
Efficiency
100 EFF
Efficiency 12.2 EER, 15 SEER
Heating input
8.6
kW
Sensible cooling
39550
Btuh
Heating output
29480
Btuh
Latent cooling
16950
Btuh
Temperature rise
14
OF
Total cooling
56500
Btuh
Actual air flow
1883
cfm
Actual air flow
1883
cfm
Air flow factor
0.056
cfm/Btuh
Air flow factor
0.049
cfm1Btuh
Static pressure
0
in H2O
Static pressure
0
in H2O
Space thermostat
Load sensible heat ratio
0.72
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wrlghtSOft' RightSuile® Universal 201212.1.05 RSUD2818 2019-May-161 Page 1
rM CAusersVason\Documents\Wrightsof AVAC1MW-260.rup Cale =MJ8 Front Door faces: W
GHO HOMES
MW-260
2974 BENT PINE DRIVE
FORT PIERCE, FL 54951