HomeMy WebLinkAboutCARPORT PLANSi
FBC APPROVED PRODUCTS r
PRODUCT CATEGORY I SUB CATEGORY
STRUCTURAL COMPONENTS ROOF DECK
STRUCTURAL COMPONENTS I STRUCTURAL WALL
STRUCTURAL COMPONENTS I FLOOD VENT
EXTERIOR DOORS I SWINGING
EXTERIOR DOORS I SWINGING
EXTERIOR DOORS .I ROLL -UP
EXTERIOR DOORS I ROLL -UP
WINDOWS ( SINGLEHUNG
CAROLINA CARPORTS, INC.
26 Gauge AG Panel
CAROLINA CARPORTS, INC.
26 Gauge AG Panel
FLOOD FLAPS, LLC
8x16 Flood Flap
ELIXIR DOOR AND METAL COMPANY
Series 402-14
ELIXIR DOOR AND METAL COMPANY
Series 407
ASTA INDUSTRIES INC.
Model 203 (1T Max. Width)
CAROLINA CARPORTS, INC.
Steel Roll Up Sheet Door (12' Max. Width)
MI WINDOWS AND DOORS
Model 185 SH
MAXIMUM ALLOWABLE
WIND SPEED
QA
APPROVAL
EXPIRATION
PARTIALLY
No.& DATE
DATE
OPEN
ENCLOSED
ENCLOSED
FL6596.1-R5
04105/27
180
180
180
10/10/17
FL6702.1-R5
03/14/27
180
180
180
10/10117
FL17387.1-R2
09/27/19
WA -
N/A
NIA
10/03/17
FL17996.3-R1
09/14120
N/A
156
138
01129/18
FL17996.5-R1
09/14/20
N/A
165
147
01129/18
FL8888.1-R5
12/31/19
WA
180
174
10/06/17
FL16806.1-R2
11/11/20
WA
158
138
01/10/18
FL17499.1-R4
10/17/23
WA
175
157 -
12129/17
NOTES: .. .. .. - .. .. . .
I. DOORS AND WIN0OWS SHOWN MAY BE SUBSTITUTED FOR DIFFERENT PRODUCT LINES ANOIOR MODELS, PROVIDED THE FOLLOWING CONDITIONS ARE MET:
A. PRODUCT SHALL HAVE A VALID FBC PRODUCT APPROVAL. - B. COMPONENTS ARE INSTALLED ACCORDING TO MANUFACTURER'S INSTALLATION REOURIEMENTS.
2. FRAMING CONNECTIONS FOR DOOR AND WINDOW FRAMES REMAIN THE SAME FOR SUBSTITUTED PRODUCTS; HEADERS AND WINDOW RAILS MAYBE RAISEO,OR LOWERED AS NECESSARY TO ACCOMODATE
SUas'nn UTED PRODUCT:
GENERAL NOTES:
1, THESE PLANS PERTAIN ONLY TO THE STRUCTURE, INCLUDING MAIN WIND FORCE RESISTING SYSTEM, COMPONENTS AND CLADDING, AND RAIL ANCHORAGE. OTHER DESIGN
ISSUES, INCLUDING BUT NOT LIMITED TO PLUMBING, ELECTRICAL, INGRESSIEGRESS, PROPERTY SET -BACKS, FINISH FLOOR ELEVATION AND SLOPE, OR OTHER LOCAL ZONING . .
REQUIREMENTS ARE THE RESPONSIBILITY OF OTHERS. -
2. THESE STRUCTURES: ARE DESIGNED'AS NON -HABITABLE UTILITY/STORAGE.BUILDINGS (RISK CA 7EGORY )) CAPABLE OF SDPPORTING DEAD LOAD OF THE STRUCTURE AND APPLICABLE
LIVE AND WIND'LOADS. IMPROVEMENTS NOT SPECIFICALLY ADDRESSED HEREIN,INCLUDINGDOORS,WINDOWS. OR OTHER COMPONENTS" NOT LISTED IN THE FBC APPROVED "-
PRODUCTS LIST (THIS SHEET), AND NOT PROVIDED AND INSTALLED BY CARDLINA CARPORTS, INC.; W' HICH DCERT.ADDITIONAL LOADS ONTHE:STRUCTURE SHALL BE AT THE OWNER'S
RISK. BECHTOL ENGINEERING AND TESTING, INC.; SHALL' NOT BE RESPONSIBLE FOR STRUCTURAL DAMAGE. OR FAILURE DUE TO THE APPLICATION OFADDITjoNAL-LOADS. - -
3. ALL STEEL TUBING SHALL BE 50XSI GALVANIZED STEEL. ALL FASTENERS SHALL BE GALVANIZED OR STAINLESS STEEL.
4. ALL COMPONENTS AND CLADDING SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S INSTALLATION_ INSTRUCTIONS, AND SHALL MEET THE DESIGN PRESSURES REQUIRED BY THE
FLCRIDA BUILDING CODE (FBC) AT,THE LOCATION OF THE BUILDING.WITHIN TH,E STATE OF FLORIDA.-
5. ALL FIELD FRAMING CONNECTIONS SHALL, BE #12-14 x 3/4' SELF DRILLING SCREWS WITHOUT CONTROL SEAL WASHER. ALL SHOP FRAMING CONNECTIONS SHALL BE WELDED.
6. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH O .5.00 PSI AT 28 DAYS. THE REINFORCING STEEL SHALL BEN INIMUM GRADE 40. CONCRETE SLAB FOUNDATIONS SHALL
BE REINFORCED WITH 6X6-WI. .4XW1 .4 WELDED WIRE FABRIC COMPLYING WITH ASTM A 185, OR WITH SYNTHETIC FIBER REINFORCEMENT COMPLYING WITH ASTM C1116:
7. BASE RAIL GROUND ANCHOR REQUIREMENTS:.O.NE WITHIN 6' OF EVERY POST LOCATION, AND BOTH SIDES.OFOPENINGS WHEREBASE RAIL IS ABSENT. GROUND ANCHORS ARE NOT
REQUIRED FOR. CONCRETE FOOTING ANDIOR CONCRETE SLAB CONSTRUCTION. SEE GROUND ANCHOR SCHEDULE (THIS SHEET) FOR SPECIFIC TYPE GROUND ANCHOR REQUIREMENTS.
8. CONCRETE ANCHORS SHALL BE TAPCON.REDHEAD LOT 1/2' x 5' OR EQUIVALENT OR WEJ-IT ANKR-TITS MODEL AT1252, OR SLEEVE ANCHOR MODEL HSA 1260, OR EQUIVALENT.
9. POSWRAFTI=R BRACING: BRACE ON EVERY POST/RAFTER CONNECTION, EXCEPT FOR END WALLS. -
10. SLAB FOUNDATION SUBGRADE SOILS SHALL BE TERMITE TREATED AND COVERED WITH 6 MIL VAPOR RETARDER PER SECTION R318.1 OF THE FBC SIXTH EDITION (2017)- RESIDENTIAL,
AND SECTION 1816.1 OF THE FBC SIXTH EDITION.(2017) - BUILDING. MINIMUM ALLOWABLE FOUNDATION SOIL CONTACT BEARING PRESSURE OF 2,000 PSF IS ASSUMED.
11. 14 GA FRAMING: 2-1/2' x 2-1/2' TUBESTEEL.(TS) WITH 2-1/4' x 2-1/4' TS NIPPLES.
12 GA FRAMING: 2-1/4' x 2-1/4' TS WITH T x 2' TS NIPPLES.
12. ENCLOSED AREAS REQUIRING FLOOD OPENINGS. MUST HAVE A MINIMUM OF TWO (2) OPENINGS ON EXTERIOR WALLS. OPENINGS SHOULD BE INSTALLED ON AT LEAST TWO (2) SIDES OF CAROLINA CAA i '; WC.
ENCLOSED AREA,WITH BASE OF OPENINGS SET WITHIN 1-FOOT OF THE HIGHER OF INTERIOR OR EXTERIOR GRADE. REQUIRED TOTAL NUMBER OF FLOOD VENTS NOTED IN THE FBC
APPROVED PRODUCTS LIST SHALL BE BASED ON ONE (1) FLOOD VENT PER EVERY 220 SQUARE FEET OF ENCLOSED AREA. SEE TYPICAL FLOOD VENT FRAMING PLAN, SHEET 5OF 6. GENERIC PLANS FOR USE'IN THE STATE OF FLORIDA
FILECOPY
� °C 2112119
BECHTOL ENGINEERING; _ RR NTS.
.woTearauaaw:
m:nso�ra rii.ue.,rza..>Emoom� '� TB a G79001 -
'^�'@T9 SHEETI OF
TABLE I
RAFTER I;,. _ -'IE, END POST, GROUND ANCHOR AND PANE;`,,,> STENER SPACING SPECIFICATIONS
AVERAGE FASTENER SPACING
ON -CENTERS ALONG RAFTERS OR
MAXIMUM PURUNS, AND POSTS OR GIRTS
WIND ULTIMATE NOMINAL POST/RAFTER - (INCHES)
RISK EXPOSURE WIND SPEED WIND SPEED SPACING INTERIOR END
CATEGORY CATEGORY (MPH) I (MPH) (FEET) POSTS/RAFTERS POSTS/RAFTER1
14
-16
= 18•
20.
L9 -22'
J . 24
Cc?.26
28
G
C
ar V"OUW
-BY;-iu I to-,,;}'
�_ ._ .7:U� -_-'�
-
151 TO 180 I
1.117T(51139
4.0�J.
6
6
1. Specifications applicable to 26 gauge metal roof and wall panels fastened directly to 12 or 14 gauge steel tube framing, or 18
gauge hat channsl. roof pudins.'
'
2. Specifications applicable only for mean roof height of 20 feet or less, and roof slopes of 7' to 27' (1.5:12 to 6:12 pitch). Spacing
requirements for other roof heights and/or slopes may.6ary, . .
GROUND ANCHOR SCHEDULE,.
ULTIMATE WIND SPEED (Blph)::., .
- METAL'CARPORT INSTALLATION PLANS
110 120 130..'140 `150, : 160, '170, 180
AND DETAILS AND -FRAMING AND
FASTENER SPECIFICATIONS
..FOR CONSTRUCTION IN THE STATE OF FLORIDA
- - - ,
-
7AnhCor
Fi.
PREPARED FOR.,
_
CAROLINA CARPORTS, INC.
P.O. BOX 1263
DOBSON, NORTH CAROLINA 27017
PREPARED BY.,
BECHTOL ENGINEERING AND TESTING, INC.
_ - gp•Ancha
605 WEST. NEW YORK AVENUE
' Detail lC
DELAND FLORIDA 32720
Certificate of Authorization No. 00005492
LS 1C'AND 1D SHOWN ON SHEET 4'0F 6
REVIEWED FOR
CODE COMPLIANCE
ST. LUCIE COUNTY
BOCC
1g0q7-o t Sat
THIS IS TO CERTIFY. THAT THE CALCULATIONS AND
SPECIFICATIONS HEREIN HAVE BEEN PREPARED BY THE
UNDERSIGNED PROFESSIONAL ENGINEER, AND ARE IN
"
ACCORDANCE WITH THE REQUIREMENTS OF SECTION.1609 OF
THE FLORIDA BUILDING CODE, SIXTH EDITION (2017). THE PLANS
ARE VALID UNTIL THE NEXT REVISION OF THE FLORIDA BUILDING
CODE
BECNTOL ENGIN _ STis ,4y�i
FLORIDA
DE AND, R
of
0.3 ,
SCANNED
3g
- S =_
St Wcieuniy
Plodaeftoi�se as STA
BOW FRAME RAFTER' EN CARPORT - HORIZONTAL ROD'
TYPICAL SIDE ELEVATION
NOT TO SCALE '
TYPICAL END ELEVATION
NOT TO SCALE
BOX EAVE FRAME RAFTER OPEN CARPORT - HORIZONTAL ROOF
TYPICAL END. ELEVATION.
NOT TO SCALE
BOX EAVE FRAME RAFTER OPEN CARPORT -'VERTICAL ROOF
TYPICAL BOW RAFTER GABLE END ELEVATION
NOT TO SCALE
BOW FRAME RAFTER ENCLOSED BUILDING - HORIZONTAL ROOF
ROLL-UPDOOR SWINGINGDOOR
(As aPDlicable)-I (As appr--de),
TYPICAL END ELEVATION
NOTTOSCALE
TYPICAL -SIDE ELEVATION - TYPICAL END ELEVATION
NOT TO SCALE NOTTOSCALE
BOX EAVE
RAFTER ENCLOSED
TYPICALBOX EAVE RAFTER GABLE END ELEVATION
NOT TO SCALE
(As
= VERTICAL ROOF
TYPICAL END ELEVATION
NOT TO SCALE
BOW FRAME RAFTER UTILITY Bl,,;:)ING - HORIZONTAL ROOF
ROLL-UPDOOR SWINGINGDOOR
(As avvnwbie), (As aPPlimble),
BOX EAVE FRAME RAFTER UTILITY BLDG - HORIZONTAL ROOF
TYPICAL SIDE ELEVATION
NOTTOSCALE
TYPICAL END ELEVATION.
NOT TO SCALE
BOX EAVE FRAME RAFTER UTILITY BLDG - VERTICAL ROOF
TYPICAL SIDE ELEVATION TYPICAL END ELEVATION
NOT TO SCALE - NOT TO SCALE
VIEWED FOR
CODE COMPI
ST. LUCIE C(
—C
TYPICAL BOX EAVE RAFTER GABLE END ELEVATION
NOT TO SCALE
BECHTOL
6DS WEST NE
I
CAROLINA
GENERIC PLANS FOR USE IN THE �S1�idt�
BECNTOL ENGINEERING
AND 7HTOLNe.
muieoor�-rwonm�ur¢uoiuieuuenn�oeom.
us.uma.e®m
FLORIDA
26GAGALVAND7-- ..+rALR00FPANELS
FASTENED TO RAFTERS PER MANUFACTURERS
INSTALLATION INSTRUCTIONS
12
-24' 16 GA U-CHANNEL BRACE
FASTENED TO RAFTER WITH
(2) #12-14 x 3/4' SDFS AT
EACH END (4 PER BRACE)
TYPICAL
INTERIOR RAFTERIPOST. FRAME SECTION - BOW FRAME
NOT TO SCALE
TYPICAL SIDE
IIZED.METAL ROOF PANELS
RAFTERS PER MANUFACTURER'S
INSTRUCTIONS
12
24'. 16 GA U-CHANNEL BRACE
FASTENED TO RAFTER WITH
(2) 012-14 x 3/4' SDF`s AT
EACH END (4 PER BRACE)
TYPICAL INTERIOR RAFTERIPOST
FRAME SECTION - BOX EAVE - HORIZONTAL ROOF
NOT TO SCALE
TYPICAL RP
NOT TO SCALE
SEE
U1LE 1 OPENING FOR SWINGING
HEET DOOR WITH NONSTRUCTURAL
OFB rHEADER
LD
s
OPTIONAL 24'_-l" TO 30' TRUSSED RAFTER - BOW
NOTTOSCALE -
LENGTH VARIES DEPENDING ON
JMBER AND SPACING OF RAFTERS
H
a
TER/POST.FRAMING PLAN -BOX EAVE
SEE
TABLE 1
6--
26 GA. GALVANIZED METAL ROOF I; .6
FASTENED TO PURLINS PER MANU,R� i URERS
INSTALLATION INSTRUCTIONS
1.1/2' 18 GAUGE FURRING
CHANNEL (PURLIN)
24' 16 GA U-CHANNEL BRACE
FASTENED TO RAFTER WITH
(2) #12-14 x 3/4' SDFs AT
EACH END (4 PER BRACE)
�1-1/2118 GAUGE FURRING CHANNEL FASTENED
TO.EACH RAFTER WITH (2) 012-14 x 3/4'SELF DRILLINGFASTENERSPACED.NOT• MORE THAN 48' O.C. -
3.
4 .
SEE
.TABLE 1
SHEET
1OF6
_
-
LENG WVIES DEPENDING ON NUMBER
-: AND SPACING OF RAFTERS
TYPICAL _
POST/RAFTER FRAMING PLAN - VERTICAL ROOF
NOTTOSCALE
TYPICAL -
END WALL OPENINGS POST/RAFTER FRAMING PLAN
NOT TO SCALE
OPTIONAL 24'-V TO 30,' TRUSSED RAFTER - BOX EAVE
NOT TO SCALE
_S
.TYPICAL.BOW RAFTER GABLE END FRAMING PLAN.
NOT TO SCALE - - - - - -
TYPICAL BOX EAVE RAFTER GABLE END FRAMING PLAN
NOTTOSCALE
REVIEW 'mq FOR.
CODE COMPLIANCE
ST. LUCIE COUNTY
B00C
24' 16 GA U-CHANNEL BRACE
FASTENED TO RAFTER WITH
(2)#12-14 x 3/4' SELF-DRIWN_ G
SCREWS AT EACH END
(4 PER BRACE)'
v ROOF ExTENSION OPTION -- MAIN STRUCTURE STANDARD LEAN-TO OPTION
TYPICAL LEAN-TO OPTIONS FRAMING PLAN BOTH OPTIONS -SHOWN) . , , , , ,
24' 16 GA U-CHANNEL BRACE (S TO T. POST)
48' 16 GA U-CHANNEL BRACE (8' TO 14' POST)
BRACE ANGLE SHALL BE MIN. 36'
1
I
MINIMUM
1.1W x MINIMUM S' TAPCON REDHEAD LOT
di OR 11T x MINIMUM 5-12' EXPANSION ANCHOR
TKKVUGH BASE RAIL WITHIN 6' OF EACH
RAFTER POSTS ALONG SIDES AND EVERY END
,WALL POST ALONG END WALL SECTIONS
2.112' EMBEDMENT
A�
CONC. FOOTING (25D0 PSI MIN.)
WITH 2 #SS CONTINUOUS
�x1 CONCRETE BASE RAIL ANCHORAGE
Not To Seale.
DRILL 5/W HOLE THP
BASE RAIL AND E
ANCHOR EYE WITH 12'
RAIL
(SEEGRQUND'ANCHOR
MINIMUM 4' SCHEDULE: SHEET I OF 6,
-' FORREQUIRED ANCHOR)
L CONTINUOUS 4' .
CONCRETE PAVEMENT.
EYE ANCHOR
�� CONCRETE BASE RAIL ANCHORAGE
NM 7o Scale (OPEN CARPORTS WHERE SLAB EDGE DISTANCE DOES NOT
.. MEET MINIMUM EDGE DISTANCE SHOWN IN DETAIL IB)
TS TRUSSED RAFTER CHORD, /
OR NONSTRUCTURAL HEADER J
TS END POST OR DDOW
WINDOW FRAME POST 2'x2-x2' 16 GA ANGLE CLIP
SECURE TO POST (EACH SIDE)
TS BASE/WINDOW RAIL OR AND RAFTER CHORDIRAIL WITH
NONSTRUCTURAL HEADER (4)#12-14 x 3f4'SDPs,(2) ON
(12 GA IF ROLL -UP DOOR FRAME) TOP OR BOTTOM, (2) ON SIDE
NOTE: ATROLL-UPDOOR
OPENINGS, POST SHOULD
BE FLUSH WITH RAIL END.
CUP POST TO RAIL ONLY ON
SIDE OPPOSITE THE OPENING.
INSTALL 1/2' x MINIMUM 5' TAPCON REDHEAD LOT -
ANCHOROR1/2'x MINIMUM 6-12' EXPANSION ANCHOR DRILL 518' HOLE THROUGH THE TW_, 'S DRILL5/8' HOLE T;�,. .,tiiH THE TWASHERS
THROUGH BASE RAIL WITHIN B'OF EACH BASE RAIL AND SECURE TO - BASE RAIL AND SECURE TO
RAFTER POSTSALONG SIDES AND EVERY ENO ANCHOR EVE WITH 12'DUlMETER TS CONTINUOUS ANCHOR EYE WITH12'DIAMETER
TS CONTINUOUS
WALL POST ALONG END WALL SECTIONS THROUGH -BOLT BASE RAIL THROUGH -BOLT BASE RAIL
MIN. 8' TOP OF ASPHALT PAVEMENT TOP OF ASPHALT PAVEMENT
OR STABLE GROUND SURFACE OR STABLE GROUND SURFACE
MINIMUM 2-12' EMBEDMENT _
EYE ANCHOR
618' ROD 48' LONG
-^ WTTHWHELIX - ..
OR
SW ROD 60' LONG (SEE GROUND ANCHOR EYEANCHOR (SEEGROUND ANCHOR
MINIMUM 4' WITH THELU(, SCHEDULE: SHEET1 OF 6, 518'ROD3D'LONG SCHEDULE, SHEET I OF 6,
AS APPLICABLE FOR APPLICABILITY) ., WITH DBL 4'HELIX .. FOR AP,PLICABILITV) _
CONTINUOUS 4' CONCFIETE PAVEMENT '
�DLONCRETE BASE RAIL ANCHORAGE BASE -RAIL DEEP ANCHORAGE BASE RAIL �CH,
IAEle(OPTIONAL=OPEN CARPORTS ONLI) IvI L
24' 16 GA U-CHANNEL BRACE (6TO T POST) TS BOW RAFTER e' LONG TS NIPPLE
46'.16 GA U_ -CHANNEL BRACE IS TO IN POST) _ _ .. SECURE POST TO NIPPLE
BRACE ANGLE SHALL BE MIN.4S ' ' WITH 4 POST O NIPPLE
TO. MAX. 60' FROM HORIZONTAL.l NOSCREWS �� - ( )
6'.LONG TS NIPPLE
SECURE POST TO NIPPLE WITH
(4) #12-14 x 3W SDPs
RAFTERPOST
BOX EAVE RAFTER/POST DETAIL
GM Not TO Swla - - -
TS RAFTER
1-12' x IAIT x T 16 GA CUP
ANGLE SECURE TO
POST AND BASE RAIL
WITH (4) #12-14 x 3W SDF's,
(2) ON TOP, (2) ON SIDE
_24' 16 GA U-CHANNEL BRACE (E TO T POST)
48' 16 GA U-CHANNEL BRACE (8' TO IN POST)
BRACE ANGLE SHALL BE MIN. 45' -
TO MAX. 60' FROM HORIZONTAL NIPPLETO
BASE RAIL
r1,/,/ 6' LONG TS NIPPLE
SECURE RAFTER AND POST TO
NIPPLE WITH (4) #12-14 x 3/4'
AFTER POST SELF -DRILLING FASTENERS
BOW-RAFTER/POST DETAIL
GD 'Not TO Scale - -
POST
-2'x 2'x 2' 16 GA ANGLE CLIP -
SECURE TOPOSTAND TOP OF
HEADER, OR BOTTOM OF WINDOW
RAIUGIRT WITH (4) #12-14k3/4'SDPS
(2) ON TOP OR BOTTOM, (2) ON SIDE
NONSTRUCTURAL HEADER
TS WINDOW RAILOR GIRT
FOR VERTICAL SIDING OPTION
�TSCONTINUOUSBASERAIL 'NON-STRUCTURAL HEADER,. WINDOW
POST TO RAIL, TRUSS CHORD, OR END POST/BASE RAIL CONN. RAIL, OR GIRT TO POST CONN. DETAIL
NON-STRUCTURAL HEADER CONN. DETAIL 5 Nat To SOale " NDt TD SDal6
Not To Seale
RAFTER POST
CONTINUOUS SASE RAIL
POST/BASE RAIL CONN: DETAIL
s
MWED FOR
CODE COMPLIANCE
ST. LUCIE COU IH I8F�''%
BOCC �C�P \,\GENSF
. BECHTOLENGINE�Mi� iND71xxm9of
606WESTNEWYORKAUEDELAND.
PLORIDA 32110-,CGrUrIC1110 'of
Lu
ilnmma PE i T �.. FOR\�.••'
\�
AND
`2'x4' 16 GA PLATE
SECURE TO.EACH SIDE OF,
TS END POST POSTIRAFTER CONNECTION
WITH (4) #12-14 x W SDFs,
(2) ON POST, (2) ON RAFTER
�-- END POST/RAFTER CONN. DETAIL
1 Not To Scale -
x216 GACUP
ANGLE SECURE TO RAFTER'
AND GABLE RAIL WITH (4)
#12-14 x 3/4' SDF's, (2) ON TOP,
1-11Z x 1-10 x 2' 16 GA (2) ON BOTTOM
CLIP ANGLE SECURE TO.,
RAFTER POST AND GABLE
RAIL WITH(4) #1244 x iW%DF's
(2) ON TOP, (2) ON SIDE TS GABLE RAIL
TS RAFTER POST .
GABLE, RAIL TO RAFTER POST
�1 CONNECTION DETAIL
' �" Naroswe
u� ►-
2-1/4'.FOR .
12 GA FRAMING
2-1/2 FOR
.14 OA FRAMING
16 GAUGE U-CHANNEL BRACE
FASTENED TO THE POST AND
RAFTER WITH (2) #12-14 x 3/4' SOFS
AT EACH END (4 PER BRACE) —
BRACE SECTION
Not TOScala
NIPPLETC
DBL. HDR.
6' LONG TS NIPPLE
SECURE EACH WITH
(4) 012-14 x 314'
SELF -DRILLING FASTENERS
2 GA TS POST
%1 RAFTER POST/DBL., HEADER DETAIL
Not To Sole
I RAFTER 12' LONG TS
SECURE POST TO
_ WITH(4)#12-14x 31,
1-1/2' x 1-10 x 216 GA CLIP ANGLE
SECURE TO RAFTER AND GABLE
RAIL WITH (4) #12-14 x 3/4' SDFs,
(2) ON TOP, (2)ON BOTTOM
6' LONG TS NIPPLE 46' 16 GA
_ SECURE RAFTER AND POST TS GABLE RAIL
TO NIPPLE WITH 314' -
SELF -DRILLING FASTENERS
,. TS RAFTER POST,
GABLE RAIL TO.. RAFTER -POST
.CONNECTION -DETAIL ; .
.110 Not TO Scale - -
1-1/2' 18 GAUGEFURRING CHANNEL FASTENED
TO EACH.RAFTER WITH (2) #12-14 x 314• SDF
SPACED NOT MORE THAN 4S' O.C.
r26 GA METAL ROOF
LTS RAFTER
,RQQD EU PANE0 1 gi i i; 0MK4ENTi�*
(ALTERNATE FOR�VERTICA_L!IROOF,PANSM) _
Not To Sole _ � -
RAFTER POST
8' LONG TS NIPPLE
SECURE WITH (4) #12-14 x 314'
SELF -DRILLING FASTENERS
GA DOUBLE TS HEADER
RAFTER POST/HEADER DETAIL
Not To Sole - -
'PPLE TO 3/16 f
4FTER
TS NIPPLE
WITH (4) #12-14 x 3W SDFs
r, 4_V:LL
UW,NFL BRACE (6 TO T POST) '
NNEL BRACE (S TO 14' POST) .
ICE ANGLE SHALL BE MIN:45• "
,MAX. 60• FROM HORIZONTAL- ;TS gAFTERPC
SIDE. EXTENSION'
RAFTER/POST DETAIL
1c Not To Scale
TS LEG
TS
TS BASE
SEE GENERAL NOTE No: 12, SHEET 1 OF 6.
6' LONG TS NIPPLE
SECURE EACH WITH (4) #12.14 x 314'
SELF -DRILLING FASTENERS
- �12 GA TS POST
3H6' NIPPLETO
BASE RAIL
. RAFTER POST/BASE
.,.RAFTER
BASERAILCONNECTION'DETAIL
1t' NW To Scale
TS RAFTER POST
2'x4' 16 GA PLATE (ONE REQUIRED)
SECURE TO EITHER SIDE OF
POST/RAFTER CONNECTION
WITH (4) #12-14 x 314' SDFS,
.(2) ON POST, (2)ONRAFTER
L2'x2'x2' 16 GA ANGLE CUP
SECURE TO POST ANO .
RAFTER WITH AND, x 3/4'
SDFs, (2) ON RAFTER,
(2) ON POST
,1 POST./ LEAN;O FI�FTER CONN. DETAIL
1J NoI TO Scale �, v �' -
CODE CONta�+d
ST. LUCIE ( AN4T`tP .
B44tillll�/;,,
R. H
ranee ,
RKA %,.•�"CC` .• 0 i
32r2o�
No 8538 c
�': COS,'•. OCORI .••`G�\
s ,t
e
,:
'a""•:
+�
i�
{
�N..
yb
ri
i'
VERTICAL SIDE OPTION
GIRT
(1ypIar
BOX EAVE FRAME RA
TYPICAL SIDE.ELEVATION
NOT TO SCALE
SEE •
D BLDG - VERTICAL SIDES
DLL Up DOOR SWINGING DOOR
(AseGPlicaNe), ' (Aaapplicable),• .
GIRTS
(TYPicaQ
1.1/2.18 GAUGE FURRING CHANNEL FASTENED TO
EACH RAFTER WITH (2) #12-14 x 314' SELF -DRILLING
6' FASTENER SPACED NOT MORE THAN 48' O.C.
OPENING FOR SWINGING DOOR
WITH NONSTRUCTURArL HEADER
g,.
4
SEE "
TABLE 1
SHEET
. 1OF 8.
9
fi.
0
• o
aM
a
fifi
12 MAX OPENING FOR
ROLL-UPDOORWT(H
STRUCTURAL HEADER
4.
4.
4
4
'
4
a
4
s..
• OPENING FOR WINDOWWfIH
NON-STRUCTURAL HEADER
LENGTH VARIES DEPENDNG ON NUMBER --ANDmDDWRAIL
AND SPACING OF RAFTERS NO•o ev�o.bf. m EM We ).
TYPICAL POST/RAFTER/GIRT FRAMING PLAN
NOT TO SCALE -
BOX EAVE FRAME RAFTER UTILITY BLDG - VERTICAL SIDES_
.. - ROLL•UP. DOORSWINGING DOOR
(As applicable),- w(As applicable)
TYPICAL SIDE ELEVATION
NOTTOSCALE
TYPICAL END ELEVATION
NOT TO SCALE. -
REVIEWED FOR
CODE COMPLIANCE
ST. LUCIE COUNTY
BOCC
H..F�
P.• CENS
D TEST • m INC. •.�
No.38538
S/ ONA0 1���`�*\