HomeMy WebLinkAboutSURVEYSo-
GUIDE POLE
Center
Line
rj-� I 7 C
F
D-
0
Mean High Tide_ _ _ 10 WELD E
9� 6---
J�Mean Low Tide
Existing Berm
(Depth Varies)
24" Min.
Embedment
Typical Section @ Seawall
Scale: 318" = 1'--0"
DATE NOTES REVISIONS
0110712018 Changed FBC Note.
N
F
A
K
MAY - 9 2019
NOT VALID U SS SIGNED WITH
ORIGINAL E GINEER'S SIGNATURE
AND RAI ED EMBOSSED SEAL
MARK E. WEBER, P.E.
LICENSE #538951 CA 30702
G 6'
(Typical
Can Vary)
65'-90' 1
V9
L
Exist. Seawall
To Remain
File Copy.
(q67-62_3
VIEWED FOR
DE COMPLIANCE
LUCIE COUNTY
BOCC
ainless steel threaded rods
HY 150 or approved equal),
embedment set in epoxy
SCANNED
CPT
General Notes. S't:Lucie Con*
• Design in accordance with Florida Building Code, 6th Edition (2017).
o This lifting structure has been designed to withstand wind loads associated with speeds of V (ult) = 180 MPH, (3 Second
Gust) Exposure V without a boat on the lift per ASCE 7-10 using above ground sign/wall method. The lifting structure
including boat has been designed to withstand wind speeds of V (ult) = 73 MPH in Exposure V.
r Boats shall not be stored on lift during high wind events.
• Do not scale drawings for dimensions.
Licensed Contractor to verify location of existing utilities prior to commencing work.
r The Licensed contractor to install and `remove all shoring and bracing as required for the proper installation of the work. `
• Licensed Contractor to obtain all permits as necessary from all Local, State, and Federal agencies.
Aluminum: Material 6061 T6 Aluminum, all welds are min. 4" full fillet weld using 5556 filler alloy, all welding must conform to
AISC steel construction manual 14th ED as inspected and verified by others. The contractor is responsible to insulate aluminum
members from dissimilar metals to prevent electrolysis.
Aluminum members in contact with concrete and wood shall be protected by "Koppers Bituminous Paint" or Polyethylene Tape
UHMW (ultra high molecular weight). 11.7 mils (0.30 mm) min. total thickness in accordance with current Florida Building Code.
• All anchors to be Hilti Brand or Approved Equal. All bolts shall be hot dipped galvanized or stainless steel & meet the
requirements of ASTM A304 with hardened washers and hex nuts. Washers shall be used between wood & bolt head & between
wood & nut. Where generic fasteners are labeled in details, capacities shall be equal to or greater than Hilti Kwik Bolt 11 or
Red Head thru bolts SAE Grade 5 or better. Embedment depths specified herein are depths into solid substrate and do not
included thickness of other finishes. ,
r MW Engineering has no control of the manufacturing, performance or installation of this product. These generic plans were
engineered in accordance with accepted engineering practices and data provided by the manufacturer.
• Piles shall be driven to refusal and sufficiently penetrated into sand or rock strata to support lift capacity, weight and loads.
• Each pile to carry commensurate load I.E. 114th lift capacity for 4-post lift (Factor of Safety of 1.5)
Allowable minimum compression pile capacity of 5 tons.
• The contractor of record shall verify pile type, installation and driving in compliance with FBC 6th ED (2017)
• Sub -surface conditions can vary greatly. , ,
MW, ENGINEERING, INC
902 NE 1 Street Suite #2
Pompano Beach, Florida 33060
Ofc:754-333-0877
WW W. MwEngineering.net
Proposed Elevators
5,000 lb
to
24,000 lb
NEPTUNE BOAT LIFTS
228 SW 21 Terrace
Fort Lauderdale, Florida 33312
Phone:954-524-3616
Fax:954-524-3604
32
aTE 05.1L015
D WN ac WRT
CHECKED BY. WM
JOB, No: Elevator 32.Eeg
Sheet 1 of 3
REVIEWED FOR
CODE COMPLIANCE
GUIDE POLE N� J F ST" LUCIE COUNTY
M SOCC
F
Center D ° �3min
Line O G 10
f _ / 65 -90' D
8 -I' 8 Equal 3" Min.
Q R I 7 a Equal t 3 Min.
B C % A Varies
Existing Seawall, Dock and
' See Anchor Dock Piles To Remain
' Schedule 1
10 WE E a ® (3) }J"O thru bolts with
9 �— 6 — - H 0 square
" thick aluminum
s
6' square washers
Mean High Tide (Max)
d (Cable Option) D stainless steel
(Cable Option)° eye bolt attached to existing seawall
stainless steel cable cap, min. 3" embedment and 6"
\\\ — Mean low with clamps
Tide — — — — — — min from any concrete face
--------------- K ANCHOR SCHEDULE I
SLOPED TRACK BEAM
Existing -Berm (3) J'0 thru bolts (except for 5K elevator which required
thr
(Depth Varies)
---------- --------------- (2) r4 0 in., bolts onlyit 3 ' mini, from top of pile, ar
apart min., centered with 3"x3"xiq" thick aluminum square
washers
----------------
VER77CAL TRACK BEAM (See Connection Detail)
24" Min. (4) jq70 thru bolts, 3 J" min. from top of pile, 3" apart
Embedment Typical Section C Dock min., centered with 3xX" " thick aluminum square washers
\ [ Scale.. 318"
MAY - 91019
DATE
NOTES REVISIONS
NOT VALID UNLESS SIGNED WITH
ORIGINA ENGINEER'S SIGNATURE
AND ' ISED EMBOSSED SEAL
MW ENGINEERING INC
902 NE 1 Street Suite #2
Pompano Beach, Florida 33060
Ofc: 754-333-0877
WWW.MwEngineering.net
Proposed Elevators
5,000 lb
to
24,000Ib
NEPTUNE BOAT LIFTS
228 SW 21 Terrace
Fort Lauderdale, Florida 33312
Phone: 954-524-3616
Fax:954-524-3604
SCALE- 32
01 0712018
Changed FBC Note
DATE. 05.12.2015
DMWN BY. war
CHECKED Hf. wM
'
MARK E. WEBER, r.E.
LICENSE#538951CA30702
JOB No: Elevator 32.dw9