INCLUDES:
• True Power'" Electrical Technology
• Two Line LCD Multilingual Digital
Evolution'" Controller(English/Spanish/
French/Portuguese)
• Two Transfer Switch Options Available:
100 Amp, 16 Circuit Switch or
200 Amp Service Rated Smart Switch.
See Page 4 for Details.
• Electronic Governor
• Standard Wi-Fi" Remote Monitoring
"" c®PYC3 E N E RAC®
RECEIVED
JUL i 12ots GUARDIAN° SERIES
5T. Lucie county, permitting
Residential Standby Generators
Air -Cooled Gas Engine
SCANNED Standby Power Rating
BY Models G007036-1, G007037-1 (Aluminum - Bisque) -16 kW 60 Hz
St. LudeCaunty Model G007035-1 (Aluminum - Bisque) -16 kW 60 Hz
S l-.LUCIE COUNT' Models GO07039-1 GO07038 1 (Aluminum Bisque - 20 kW 60 Hz
PLAN REVIEW odEL--GD07n43-2,:Go070422-(&rninum-.SisgLe�- 2kNL60.:
• System Status & Maintenance Interval LED Indicators PLUMB:
• Sound Attenuated Enclosure DATE:
• Flexible Fuel Line Connector MECH:
• Direct -To -Dirt Composite Mounting Pad DATE:
• Natural Gas or LP Gas Operation
• 5 Year Limited Warranty
• Listed and Labeled by the Southwest Research Institute allowing
installation as close as 18° (457 mm) to a structure.*
-Must be located away from doors, windows, and fresh ail
intakes and in accordance with local codes.
httos:llassets.swri.orgllibmry/DirectooOMstedProductsl
Construcbon1ndusby1973_DoC_204_13204-01-01 Reva.pdf
FEATURES
OLIB'TEDUS QUIEHEST- i
Note: CUL certification only applies to unbundled units and units packaged with
limited circuit switches. Units packaged with the Smart Switch are UL cemfied In
the USA only.
Q INNOVATIVE ENGINE DESIGN& RIGOROUS TESTING are at the heart of Geneao's success in
O
SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION:
prodding the most reliable generators possible. Generac's G-Fame engine lineup. offers added
This state-of-the-art power maximizing regulation system Is standard on
peace of mind and reliability for when you need it the most. The G-Farce series engines are pur-
pose built and designed to handle the rigors of extended run Imes in high Nemperat res and
all Generac models. It provides optimized FAST RESPONSE to changing
extreme operating conditions.
load conditions and MAXIMUM MOTOR STARTING CAPABILITY by
electronically torque -matching the surge loads to the engine. Digital
voltage regulation at ±1%.
O TRUE POWER'- ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave
O
SINGLE SOURCE SERVICE RESPONSE from Generacs extensive dealer
farm produce less than 5°%Told Harmonic Distortion for utility quality power. This allows
network provides parts and service know-how for the entire unit, from the
confident operation of sensitive electronic equipment and micro -chip based appliances,
engine to the smallest electronic component.
such as variable speed WAC systems.
O TEST CRITERIA;
O
GENERAC TRANSFER SWITCHES: Long life and reliability are
✓ PROTOTYPE TESTED ✓ NEMA MGI-22 EVALUATION
synonymous with GENERAC POWER SYSTEMS. One reason for this
✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY
confidence is that the GENERAC product line Includes Its own transfer
systems and controls for total system compatibility.
O MOBILE LINK— REMOTE MONITORING: FREE with every Guardian Series Home
standby generator. Allows you to monitor the states of your generator tam anywhere In the
w
=
G E N E R A C "•• "� e
®,' €©a�
N
world using a smarthone, tablet, or PC, Easily access information such as the current
PROMISE +..F '
operating status and maintenance alerts. Connect your account to your authorized service
dealer for Fast friendly and proacgve service. With Mobile Link, you are taken we of before
the next power outage.
GENERAC®
16/20/22 kW
features and benefits
Engine
•
Generac G-Force design
Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinder walls and plasma moly
rings helps the engine run cooler, reducing oil consumption resulting in longer engine life.
•
"Spiny-Iok" cast iron cylinder walls
Rigid construction and added durability provide long engine life.
•
Electronic ignition/spark advance
These features combine to assure smooth, quick starting every time.
•
Full pressure lubrication system
Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine
life. Now featuring up to a 2 year/200 hour oil change interval.
•
Low oil pressure shutdown system
Shutdown protection prevents catastrophic engine damage due to low all.
•
High temperature shutdown
Prevents damage due to overheating.
Generator
•
Revolving field
Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature
generator.
•
Skewed stator
Produces a smooth output waveform for compatibility with electronic equipment.
•
Displaced phase excitation
Maximizes motor starting capability.
•
Automatic voltage regulation
Regulates the output voltage to±l%prevents damaging voltage spikes.
•
UL 2200 listed
For your safety.
Transfer Switch (if applicable)
•
Fully automatic
Transfers your vital electrical loads to the energized source of power.
•
NEMA 3R
Can be Installed inside or outside for maximum flexibility.
•
Remote mounting
Mounts near your existing distribution panel for simple, low-cost Installation.
Evolution" Controls
•
Auto/Manual/Off illuminated buttons
Selects the operating mode and provides easy, at -a -glance status indication in any condition.
•
Two-line LCD multilingual display
Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences.
•
Sealed, raised buttons
Smooth, weather -resistant user interface for programming and operations.
•
Utility voltage sensing
Constantly monitors utility voltage, setpoints 65% dropout, 80%pick-up, of standard voltage.
•
Generator voltage sensing
Constantly monitors generator voltage to ensure the cleanest power delivered to the home.
•
Utility interrupt delay
Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of
5 seconds by a qualified dealer.
•
Engine warm-up
Ensures engine is ready to assume the load, setpoint approximately 5 seconds.
•
Engine cool -down
Allows engine to cool prior to shutdown, setpoint approximately 1 minute.
•
Programmable exercise
Operates engine to prevent oil seal drying and damage between power outages by running the generator
.
for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing
flexibility and potentially lower fuel costs to the owner.
•
Smart hattery charger
Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature.
Compatible with lead acid and AGM -style batteries.
•
Main line circuit breaker
Protects generator from overload.
•
Electronic governor
Maintains constant 60 Hz frequency.
Unit
• SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding
winds up to 150 mph. Hinged key locking roof panel for security. Lift -out front for easy access to all routine
maintenance items. Electrostatically applied textured epoxy paint for added durability.
• Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent Injuries.
• Small, compact, attractive Makes for an easy, eye appealing installation, as close as 18" away from a building.
GENERAC
16/20/22 kW features and benefits
Installation System
•
1 R (305 mm) flexible fuel line connector
Absorbs any generator vibration when connected to rigid pipe.
•
Direct -to -dirt composite mounting pad
Complex lattice design prevents settling or sinking of the generator system.
•
Integral sediment trap
Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine life.
Remote Monitoring
•
Ability to view generator status
Monitor your generator via your smarlphone,tablet, or computer at any time via the Mobile Link application far
complete peace of mind
•
Ability to view generator Exercise/Run and Total Hours
Review the generator's complete protection profile for exercise hours and total hours
•
Ability to view generator maintenance information
Provides maintenance Information for your specific model generator when scheduled maintenance is due
•
Monthly report with previous month's activity.
Detailed monthly reports provide historical generator information
•
Ability to view generator battery information
Built In battery diagnostics displaying current state of the battery
•
Weather Information
Provides detailed local ambient weather conditions for generator location
GENERACe
16/20/22 kW specifications
Generator
Model G007035-1, (1007036-1, G007038-1, G007039-1 13007042-2, G007043-2
"Soul lem0 are talon 4om the banal the generator. Sound lemistamn from other sidesof the generator maybe higher depending on Intonation parameters. Bating de6ndons-Stmoby. Applicable for sopplyr g emergency power for theovarian
of the utility pwmr outage. No omdoad capablliy isoaa0able for this rating.(Magngsinan rdmuwitiBS5514,IS03046and DW6271).'Madmum NI=ftampsmdcw tmmbjedtoandiimhdbyerolfe mas Nel BU"egajmle
convent enElemkmpemhue, altiNde, engine poveard wrdidmn, am Maumum paum decreases abaut35 perromforeadh 1.000WPM moon)abmm are level; and alsawgl deoameabatl peiamfmr each 6-C I10-0 above 16-C (601).
GENERAC°
16/20/22 kW switch options
Limited Circuits Switch Features
• 16 space, 24 circuit, breakers not included.
• Electrically operated, mechanically -held contacts for fast, positive
connections
• Rated for all classes of load, 100% equipment rated, both inductive and
resistive.
• 2-pole, 250 VAC contactors.
• 30 millisecond transfer time.
• Dual coil design.
• Rated for both copper and aluminum conductors.
• Main contacts are silver plated or silver alloy to resist welding and sticking.
• NEMA/UL 311 aluminum outdoor enclosure allows for indoor or outdoor
mounting flexibility.
• Multi listed for use with 1'standard, tandem, GFCI and AFCI breakers from
Siemens, Murray, Eaton and Square D for the most flexible and cost effec-
tive install.
Dimensions
Height
Width
Depth
H1
I H2
W1
W2
in
26.75
30.1
1 10.5
13.5
6.91
mm
679.4
1 764.3
1 266.7
343.0
175.4
Wire flanges
Conductor Lug
Neutral Lug
Ground Lug
110-#14
270-#14
210-#14
Service Rated Smart Switch Features
• Includes Digital Power Management Technology standard (DPM).
• Intelligently manages up to four air conditioner loads with no additional
hardware.
• Up to four more large (240 VAC) loads can be managed when used iri
conjunction with Smart Management Modules (SMMs).
• Electrically operated, mechanically -held contacts for fast, clean connections.
• Rated for all classes of load, 100% equipment rated, both inductive and resis-
tive.
• 2-pole, 250 VAC contactors.
• Service equipment rated, dual coil design.
• Rated for both aluminum and copper conductors.
• Main contacts are silver plated or silver alloy to resist welding and sticking.
• NEMA7UL 3R aluminum outdoor enclosure allows for indoor or outdoor mount-
ing flexibility.
Dimensions
200 Amps 120/240, 10
Open Transi8on Service Rated
Height
Width
Depth
H1
H2
W1
W2
in
26.75
30.1
10.5
13.5
6.91
mm
679.4
764.3
266.7
343.0
175.4
Model
G007036-1(16kW)
Current Rating (Amps)
100
Voltage Ha(fri
UtilltyVoltage Monitor (Fixed)'
-Plck�p
-Dropout
- 120/240,10e
80%
65%
Aaturnto Ublity,'.,,..''.-,aHprox:f6sec
Exercises bl-weekly for 5 minutes't
> � _
Standard
Total Circuits Available
24
Circuit Breaker Protected
Available RMS Symmetrical 10,000
Fault Current @ 250 Volts
'Function of Evolution Controller
Exercise can be set to weekly or monthly
Model
G007037-1 (16 WO/G007039-1 (20 kW)/
G007043-2(22 kW)
No: of Pores "'- _ -
2
Current Rating (Amps) -
200
IV91iarle'Rahn9 NAC1': =;
Ublity Voltage Monitor (Fxed)•
-Pick-up
-Dropout
,y, 120/240,.10:X, _____
80%
65%
Exercises bi-weekly for 5 minulas'
Standard
Ul listed"'-',
Standard„11 '
Enclosure Type
NEMAn1L 3R
Circut iabkerProtedtetl
Lug Range
250 MGM-#6
'Function of Evolution Controller
Exercise can be set to weekly or monthly
16/20/22 kW
GENERAC
available accessories
r i(t
lndhl'ct,Q i ifflkn
The Wi-Fi enabled UP fuel level monitor provides constant monitoring of the connected LP fuel tank. Mon.
holing the LP ta*s fuel level is an Important step in making sure your generator is ready to run during an
Wi-Fij LP Fuel Level Monitor
unexpected power failure. Status alerts are available through a free application to notify when your UP tank
is in need of a refill.
Every standby generator requires a battery to start the system. Gonerac offers the recommended 26R wet
G005819-0
26R Wet Coll Battery
cell battery for use with all air-cooled standby product (excluding PowerPacte).
The pad warmerrests underthe battery. Recommended for use 9 the temperature regularlyfialls below 0°F.
G007101-0
Battery Pad Warmer
(Not necessary for use with AGM -style batteries).
G007102-0
Oil Warmer
Oil warmer slips directly over the oil filter. Recommended for use if the temperature regularly falls below 0°F.
The breather warmer is for use In extreme cold weather applications. For use with. Evolution controllers
G007103-1
Breather Warmer
only in climates where heavy icing occurs.
Auxiliary Transfer Switch
The aundiiiny transfer switch contact kit allows the transfer switch to lock out a single large electrical load
G005621-0
Contact Kit
you may not need. Not compatible with 50 amp pre -wired switches.
The fascia base wrap snaps together around the bottom of the now air cooled generators. This offers a
G007027-0 -Bisque
Fascia Base Wrap Kit
sleek , contoured appearance as well as offering protection from rodents and insects by covering the lifting
(Standard on 22 kW)
holes located in the base.
If the generator enclosure is scratched or damaged, it is Important to touch-up the paint to protect from
G005703-0 - Bisque
Paint Kit
future corrosion. The paint kit includes the necessary paint to properly maintain or touch-up a generator
enclosure.
GOO6485-0
Scheduled Maintenance Kit
Generic's scheduled maintenance kits provide all the hardware necessary to perform complete routine
maintenance an a Generate automatic standby generator.
G006873-0
Smart Management Modules are used in conjunction with the Automatic Transfer Switch to Increase its
Smart Management Module
power management capabilities. It provides additional power management flexibility not found in any other
(50 Amps)
power management system.
dimensions & UPCs
Dimensions shown are approximate. Refer to Installation manual for met dimensions. DO NOT USE THESE DIMENSIONS FOR INSTAUA11ON PURPOSES.
Model
UPC
G007035-1
696471074161
G007036-1
696471074154
G007037-1
696471074178
G007038-1
696471074185
G007039-1
696471074192
G007042-2
696471074208
G007043-2
696471074215
FIRLDIUVEA,
GENE RAC® Generac Power Systems, Inc. - S45 W29290 HWY. 59, Waukesha, WI 53189 - generac.com
ecezzZZEMERM 02018 Generac Power Sprains, Inc. All ogres reserved An specifications are Subject to Strange withoull notice. Pad No. I000DO00194.G 03/16118