Loading...
HomeMy WebLinkAboutNOAi10 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION AUTICE OF ACCEPTANCE (VOA TAMKO Building Products, Inc. SCANNED 220 West 4h Street BY Joplin, MO 64801 St. Lucie County File C®k.' IAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 Ov — 00 SCOPE: SV vi%3 OC This NOA is being issued under the applicable rules and regulations governing the use of Pnstmction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: TAMKO Roof Shingles LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal ofNOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No.15-0709.19 and consists of pages 1 through 6. The submitted documentation was reviewed by Gaspar J Rodriguez APPROVED NOA No.: 15-1215.10 Expiration Date: 12/01/20 Approval Date: 05/26/16 Page 1 of 6 ROOFING ASSEMBLY APPROVAL Category Roofing Sub -Category: Asphalt Shingles Materials: Laminate Deck Type: Wood SCOPE This approves TAMKO's Heritage, Heritage Woodgate and Heritage Premium asphalt shingles, manufactured by TAMKO Building Products, Inc., as described in this Notice of Acceptance and designed to comply with the Florida Building Code High Velocity Hurricane Zones. PRODUCT DESCRIPTION Product Heritage Manufacturing Location # 1, 2, 3 Heritage Woodgate Manufacturing Location # 1,3 Heritage Premium Manufacturing Location # 1, 2, 3 MANUFACTURING LOCATIONS 1. Dallas, TX 2. Tuscaloosa, AL 3. Frederick, MD EVIDENCE SUBMITTED Test Agency Underwriters Laboratories, Inc. PRI Asphalt Technologies, Inc. Dimensions Test _Product Description Specifications 13 Y4" x 39 3/a" TAS 110 Dimensional asphalt shingle. 13 %4" x 39 3/s" TAS 110 Dimensional asphalt shingle. 13 Y44" x 39'/s" TAS 110 Dimensional asphalt shingle. PRI Construction Materials Technologies LLC APPN0VE0 Test Identifier Test Name/Report Date TAS 107 & UL 790 04CA44252 02/25/05 ASTM D3462 02NK33813 09/23/02 ASTM D 3462 & TAS 107 R2919 Letter 03/10/11 ASTM D3462 4789110543 08/26/14 TAS 107 02/19/15 ASTM E 108 08/26/14 ASTM D3161, Class F 4787043752 10/20/15 TAS 100 TAP-129-02-01 05/26/05 TAS 100 TAP-130-02-01 05/26/05 TAS 100 TAP-131-02-01 05/26/05 TAS 100 TAP-303-02-01 12/12/14 TAS 100 TAP-307-02-01 02/10/15 TAS 100 TAP-317-02-01 09/02/15 NOA No.: 15-1215.10 Expiration Date: 12/01/20 Approval Date: 05/26/16 Page 2 of 6 I,Da TIONS I. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Shingles shall not be installed on roof mean heights in excess of 33 ft. 3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. INSTALLATION I. Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 2. Flashing shall be in accordance with Roofing Application Standard RAS 115. 3. The manufacturer shall provide clearly written application instructions. 4. Exposure and course layout shall be in compliance with Detail `A', attached. 5. Nailing shall be in compliance with Details'B', attached. LABELING Shingles shall be permanently labeled with the manufacturer's name and/or logo, city and state of manufacturing facility, and the following statement: "Miami -Dade County Product Control Approved" or with the Miami -Dade County Product Control Seal as seen below: MIAMI•DADE COUNTY M M BUILDING PERMIT REQUIIiEMENTS As required by the Building Official or the applicable Building Code in order to properly evaluate the installation of this system. This Notice of Acceptance on its own cannot be used to obtain a building permit. MIAMFDADECOUNTY NOA No.: 15-1215.10 Expiration Date: 12MI/20 Approval Date: 05/26/16 Page 3 of 6 6-1/8" MIAMIDAOE COUNTY DETAIL A HERITAGE, HERITAGE WOODGATE, AND HERITAGE PREMIUM All dimensions an: in inches. 5TH COURSE 4TH COURSE 3RDCOURSE 2ND COURSE 29 1ST COURSE i NO DETAIL B HERITAGE SHINGLE FIG. 1 FASTENING PATTERN All dimensions are in inches 39-3/8" 7'/'�I7'W 73/e 7./. 73T 1. F �I. SIG �IH ----•---- 5-5/8" NOA No.:15-1215.10 Expiration Date: 12/ol/2o Approval Date: 0526/16 Page 4 of 6 DETAIL B (CONTINUED) HERITAGE SHINGLE FIG. 2ALTERNATE FASTENING PATTERN HERITAGE SHINGLE (TUSCALOOSA9 AL) FIG. 3 ALTERNATE FASTENING PATTERN HORIZONTAL NAIL SPACING IN ACCORDANCE WITH FIG.1 OR FIG. 2. VERTICAL NAIL SPACING ALLOWED ANYWHERE WITHIN NAIL ZONE. 7-7 rha.i ClVtti LOCATION APPNOVED Common Bond NOA No.: 15-1215.10 Expiration Date: 12101t20 Approval Date: 05/26/16 Page 5 of 6 HERITAGE WOODGATE & HERITAGE PREMIUM SHINGLES FIG. 4 FASTENING PATTERN All dimensions are in inches 1° 7W 6'/:" 93/e 61/9 7YT 1° CIE CIE `>IH 1 END OF THIS ACCEPTANCE 3 -114" Exposure MIAMbDAOECOUNW NOA No.: 15-1215.10 Expiration Date: 12/01/20 Approval Date: 05/26/16 Page 6 of 6 MIMI E DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) GAF 1 Campus Drive Parsippany, NJ 07054 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida33175-2474 T (786)315-2590 F (786)31525-99 www.miamidade.gov/eeonomy. IREVIEV4.0 NCE E �omCn Kv SCOPE: Uaeuuunw File Conv5r. ti This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). SCANNFD Sf BY This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Gnventio'- nariBu► a oo stem o Woo LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 14-1030.01 and consists of pages 1 through 27. The submitted documentation was reviewed by Jorge L. Acebo. o.• ," x iratiovDate. IHO p toval Date: 0 71 LaXeAW_W ROOFING SYSTEM APPROVAL Category Roofing Sub -Category: BUR Material: Fiberglass Deck Type.• Wood Maximum Design Pressure: -97.5 psf. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description GAFGLAS® Ply 4 39.37" (1 meter) ASTM D2178 Smooth surfaced asphaltic ply sheet reinforced Wide with fiberglass mat. Tri-Ply® Ply 4 39.37" (1 meter) ASTM D2178 Smooth surfaced asphaltic ply sheet reinforced Wide with fiberglass mat. GAFGLAS® 39.37" (1 meter) ASTM D2178 Smooth surfaced asphaltic ply sheet reinforced F1exPly'". 6 Wide with fiberglass mat. GAFGLAS11#75 39.37" (1 meter) ASTM D4601 Smooth asphaltic base or base/ply sheet reinforced Base Sheet Wide with fiberglass mat. Tri-Ply®#75 Base 39.37" (1 meter) ASTM D4601 Smooth asphaltic base or base/ply sheet reinforced Sheet Wide with fiberglass mat. GAFGLAS® 480 39.37" (1 meter) ASTM D4601 Smooth asphaltic base or base/ply sheet reinforced Ultima''Base Sheet Wide with fiberglass mat. GAFGLAS® 39.37" (1 meter) ASTM D4897 Smooth surfaced asphaltic perforated venting base StratavenO Wide sheet reinforced with fiberglass mat. Perforated Venting Base Sheet GAFGLAS® 39.37" (1 meter) ASTM D4897 Smooth surfaced asphaltic nailable venting base Stratavent®Nailable Wide sheet reinforced with fiberglass mat. Bottom side Venting Base Sheet surfaced with granules. Ruberoid® 20 39.37" (1 meter) ASTM D6163 SBS polymer -modified asphalt base or Smooth Wide anchor sheet reinforced with a fiberglass mat. Ruberoid® Mop 39.37" (1 meter) Smooth wide Ruberoid® Mop 39.37" (1 meter) Smooth 1.5 wide Ruberoid® Mop 39.37" (1 meter) Plus Smooth wide Ruberoid® HW 25 39.37" (1 meter) Smooth wide ASTM D6164 Smooth surfaced mop applied SBS base or anchor sheet reinforced with a polyester mat. ASTM D6164 Smooth surfaced mop applied SBS base or anchor sheet reinforced with a polyester mat. ASTM D6164 Smooth surfaced mop applied SBS base or anchor sheet reinforced with a polyester mat. ASTM D6163 Smooth surfaced torch applied SBS base or anchor sheet reinforced with a fiberglass mat. NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 2 of 27 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Dimensions Specification Ruberoid® HW 39.37" (1 meter) ASTM D6164 Smooth wide GAFGLAS® 39.37" (1 meter) ASTM D3909 Mineral Surfaced Wide Cap Sheet Tri-Ply® BUR 39.37" (1 meter) ASTM D3909 Granule Cap Sheet Wide Product Description Smooth surfaced torch applied SBS base or anchor sheet reinforced with a polyester mat. Granule surfaced asphaltic cap sheet reinforced with fiberglass mat. Granule surfaced asphaltic cap sheet reinforced with fiberglass mat. GAFGLAS® 39.37" (1 meter) ASTM D3909 Granule surfaced asphaltic cap sheet reinforced EnergyCap' Wide with fiberglass mat. Cap sheet is factory coated Mineral Surfaced with TOPCOAT EnergyCote' Elastomeric Cap Sheet Coating. Topcoat® Surface 5 or 55 gallons ASTM D6083 Solvent -based thermoplastic rubber Seal SB sealant designed to protect and restore aged roof surfaces and to increase roof reflectivity. Topcoat® 1, 5 or 55 gallons ASTM D6083 Water -based elastomeric coating Membrane Topcoat® MB Plus 5 or 55 gallons Proprietary Water based, low VOC primer designed to block asphalt bleed -through. Topcoat® FireOuf' 5 or 55 gallons Proprietary Low VOC, water based fire barrier coating. Fire Barrier Coating VersaShield® Fire- 12" x 100' rolls ASTM D226 Non -asphaltic, fiberglass reinforced underlayment Resistant Roof and/or fire barrier Deck Protection VersaShield® Solo'' 42" roll wide, 100 ASTM D146, Non -asphaltic, fire resistant fiberglass Fire -Resistant Slip ft. D828, D4869, underlayment Sheet D6757 Topcoat® 1, 5 gallons or TAS 139 Solvent -based elastomeric sealant. FlexSeal' 1 qt. tube NOA No.: 18-0919.07 rRAMFpnpecourrrr Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 3 of 27 APPROVED INSULATIONS: TABLE 2 Product Name Product Description EnergyGuard" Polyiso Polyisocyanurate foam insulation Insulation EnergyGuard' Tapered Polyiso Insulation EnergyGuard" Ultra Polyiso Insulation EnergyGuard'" RA Polyiso Insulation EnergyGuard' RA Composite Polyiso Insulation EnergyGuard" RH Polyiso Insulation EnergyGuard' RH Tapered Polyiso Insulation EnergyGuard' RN Polyiso Insulation EnergyGuard' Perlite Roof Insulation Polyisocyanurate foam insulation Glass -faced polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation with high density fiberboard or permalite Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Perlite insulation board EnergyGuard' Perlite Recover Perlite recover board Board Securock' Gypsum -Fiber Roof Gypsum board Board Securock' Glass -Mat Roof Glass faced gypsum board Board Structodek' High Density Fiber High density fiberboard Board Roof Insulation DensDeck' Prime Roof Board Gypsum board DensDeck' Roof Board Gypsum board Manufacturer (With Current NOA) GAF GAF GAF GAF GAF GAF GAF GAF GAF GAF United States Gypsum Corp. United States Gypsum Corp. Blue Ridge Fiberboard, Inc. Georgia-Pacific Gypsum LLC Georgia-Pacific Gypsum LLC NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 4 of 27 APPROVED FASTENERS: TABLE 3 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) 1. Drill-Tec"" #12 Fastener Phillips head, modified #12 x 8" max. GAF buttress thread, pinch point, length, #3 carbon steel fastener for use Phillips head. in steel or wood decks. With CR-10 coating. Available with a pinch point or drill point. 2. Drill-Tec"° #14 Fastener Truss head, self -drilling, #14 x 16" GAF pinch point, high thread max. length, fastener for use in steel, wood 43 Phillips or concrete decks. head. 3. Drill -Tee" ASAP 3S Drill-Tec' #12 Fastener with See GAF Drill-Tec'" 3" Standard Steel components Plate. 4. Drill-Tec' 3" Steel Plate Round Galvalume® steel 3" Round GAF stress plate with reinforcing ribs and recessed for use with Drill-Tec7' fasteners. 5. Drill-Tec'" 3" Standard Steel Galvalume® coated steel 3" Round GAF Plate stress plate for use with approved Drill-Tec'°' fasteners. 6. Drill-Tec'" AccuTrac® Flat A2-SS aluminized steel plate 3" square; GAF Plate for use with Drill-Tec"' .017" thick fasteners. 7. Drill-Tec'" AccuTrac® Galvalume® steel plate with 3" square; GAF Recessed Plate recess for use with Drill- .017" thick Tee fasteners. 8. Drill-Tec 3 in. Ribbed Round Galvalume® plated 3" Round GAF Galvalume Plate (Flat) steel stress plate with reinforcing ribs for use with Drill-Tec'" fasteners. NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 5 of 27 EVIDENCE SUBMITTED: Test A9enCV Test Identifier Description Date Factory Mutual Research Corp. 3014547 4470 05/22/03 3029832 4470 05/11/07 3033135 4470 11/24/08 3034312 4470 04/09/09 3036980 4470 08/14/09 3038278 4470 11/18/11 3040738 4470 11/16/10 3041769 4470 05/26/11 3042887 4470 11/14/11 3042905 4470 01/10/12 3046081 4470 02/13/13 3046388 4470 09/24/12 3047636 4470 08/08/13 ODOA8.AM 4470 07/09/99 OD IA8.AM 4470 07/29/94 OY9Q5.AM 4470 04/01/98 1B9A8.AM 4470 09/04/97 2B8A4.AM 4470 07/02/97 3B9Q 1.AM 4470 01/08/98 3D4Q2.AM 4470 05/30/97 797-03221-267 4470 09/27/07 797-03825-267 4470 07/21/08 797-10228-267 4470 01/23/15 UL LLC R1306 UL 790 08/21/18 PRI Construction Materials GAF-122-02-01 TAS 139 05/07/06 Technologies, LLC GAF-270-02-02 ASTM D226 11/15/10 GAF-276-02-01Rev ASTM D6083 12/16/10 GAF-276-02-02 ASTM D226 11/15/10 GAF-306-02-01 ASTM E96 07/07/11 GAF-314-02-01 ASTM D2178 08/23/11 GAF-315-02-01 ASTM D2178 08/23/11 GAF-369-02-01 ASTM C1289 10/22/12 GAF-417-02-01 ASTM C1289 05/28/13 GAF464-02-01 ASTM C1289 10/22/12 GAF464-02-01 ASTM C1289 02/06/14 GAF499-02-01 ASTM D6083 03/12/14 GAF-500-02-01 ASTM D6083 03/12/14 GAF-549-02-01 TAS 114 08/08/14 GAF-549-02-02 TAS 114 08/08/14 GAF-559-02-01 TAS 117(B) 09/30/14 GAF-559-02-04 ASTM D 1876 10/01/14 GAF-559-02-05 ASTM D 1876 10/15/14 GAF-559-02-06 TAS 114(H) 10/02/14 GAF-559-02-07 ASTM D 903 10/02/14 GAF-559-02-08 ASTM D 903 10/02/14 NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 6 of 27 EVIDENCE SUBMITTED: (CONTINUED) Test Aeencv Test Identifier Description Date PRI Construction Materials GAF-559-02-09 ASTM D 903 10/02/14 Technologies, LLC GAF-559-02-11 TAS 114 10/14/14 GAF-559-02-12 TAS 114 10/14/14 GAF-559-02-13 TAS 114 10/15/14 GAF-559-02-14 TAS 114 10/15/14 GAF-559-02-15 TAS 114 10/15/14 GAF-559-02-16 TAS 114 10/15/14 GAF-559-02-18 TAS 114 10/15/14 GAF-559-02-19 TAS 114 04/16/15 GAF-628-02-01 ASTM C1289 05/31/16 IRT of S. Fl. 02-005 TAS 114 01/18/02 02-014 TAS 114 03/22/02 Trinity I ERD C8500SC.11.07 TAS 117 11/30/07 G30250.02.10-3-R2 ASTM D3909 06/03/15 G31360.03.10 ASTM D6164 03/31/10 G33470.01.11 ASTM D6164 11/16/11 G34140.04.11-2 ASTM D6163 04/25/11 G34140.04.11-4-R2 ASTM D6401 06/04/15 G34140.04.11-5-R3 ASTM D4897 06/04/15 G36780.07.11-RI 4470-TAS 114 07/18/11 G40630.01.14-1 ASTM D6163 01/06/14 G40630.01.14-2A ASTM D6164 01/07/14 G40630.01.14-2A-1-Rl ASTM D6164 04/10/14 G43610.01.14 ASTM D3909 01/22/14 G6850.08.07-1 ASTM D3909 08/13/07 SC6870.08.14-R1 ASTM D3909 09/04/14 SC9700.08.15-R1 ASTM D2178 8/31/2015 SC10680.05.16 ASTM D6163 5/10/2016 SC13105.03.17-RI ASTM D6164 3/23/2017 Dynatech Engineering Corporation 94482.02.95-1 TAS 114 09/01/95 Atlantic & Caribbean Roof 11-053 TAS 114 08/12/11 Consultants, LLC NOA No.: 18-0919.07 MIAMMAD, C01 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 7 of 27 APPROVED ASSEMBLIES Membrane Type: BUR Deck Type 1I: Wood, Insulated Deck Description: Min. 19/32" or greater plywood or wood plank secured 6 in. o.c. at panel end and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c. at max. System Type A(1): All insulation layers are adhered, to a mechanically attached anchor sheet. Membrane is subsequently fully adhered to insulation. All General and System Limitations shall apply. Fire Barrier: Topcoat® FireOut' Fire Barrier Coating, VersaShield® Fire -Resistant Roof Deck Protection, (optional) VersaShield® Solo' Fire -Resistant Slip Sheet, DensDeck® Roof Board, SecurocP Glass - Mat Roof Board or Securock' Gypsum Fiber Roof Board installed per manufacturer's installation instructions. Anchor sheet: GAFGLAS® #80 Ultima'" Base Sheet, GAFGLAS® Stratavent® Nailable Venting Base Sheet or Ruberoid® 20 Smooth mechanically fastened as described below. Fastening GAFGLAS® Ply 4, GAFGLAS® Flex Ply'" 6, GAFGLAS® #75 Base Sheet or any of above Option ft anchor sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows 18" o.c. in the field. Not for use with DensDeck or Securock Fire Barrier (Maximum Design Pressure —45 psf. See General Limitation #9) Fastening GAFGLAS® Ply 4, GAFGLAS® FlexPly' 6, GAFGLAS® #75 Base Sheet or any of above Option #2: anchor sheets attached to deck with Drill-Tec7' #12 Fastener, Drill-Tec' #14 Fastener and Drill-Tec"" 3" Steel Plate, Drill-Tec'" AccuTrac® Flat Plate or Drill -Tee AccuTrac® Recessed Plate 12" o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the sheet. (Maximum Design Pressure —45 psf. See General Limitation #9) Fastening GAFGLAS® FlexPly'" 6, GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet or any of Option #3: above anchor sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. Not for use with DensDeck or Securock Fire Barrier (Maximum Design Pressure —52.5 psf. See General Limitation #7) Fastening Any of the above anchor sheets attached to deck with approved 1'/4" annular ring shank nails Option 94: and inverted 3" steel plate at a fastener spacing of 9" o.c. at the 4" lap and in two rows staggered with a fastener spacing of 9" o.c. in the center of the membrane. Not for use with DensDeck or Securock Fire Barrier (Maximum Design Pressure —60 psf. See General Limitation #7) Fastening GAFGLAS® #75 Base Sheet or any of above anchor sheets attached to deck with Drill-Tec"" Option #5: #12 Fastener, Drill-Tec' #14 Fastener and Drill -Tee 3" Steel Plate, Drill -Tee AccuTrac® Flat Plate or Drill-Tec'" AccuTrac® Recessed Plate 12" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —45 psf. See General Limitation #9) NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 8 of 27 Fastening (Continued) Any of above anchor sheets attached to deck approved annular ring shank nails and 3" Option #6: inverted Drill-Tec' insulation plates at a fastener spacing of 9" o.c. at the 4" lap staggered in two rows 9" in the field. Not for use with DensDeck or Securock Fire Barrier (Maximum Design Pressure —60 psf. See General Limitation 97) Fastening GAFGLAS' #75 Base Sheet or any of above anchor sheets attached to deck with Drill-Tec'' Option #7: #12 Fastener or Drill-Tec' #14 Fastener and 3" Drill-Tec'" 3" Steel Plate, Drill-Tec' AccuTrac® Flat Pate or Drill-Tec' AccuTrac' Recessed Plate 8" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —45 psf. See General Limitation #9) One or more layers of any of the following insulations. Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ftz EnergyGuard'" Polyiso Insulation, EnergyGuard' Ultra Polyiso Insulation, EnergyGuard RH Polyiso Insulation, EnergyGuard'' RA Polyiso Insulation, EnergyGuard' RA Composite Polyiso Insulation Minimum 1" thick N/A N/A EnergyGuard' Perlite Recover Board, DensDeck® PrimeRoof Board Minimum %:" thick N/A N/A EnergyGuard" Perlite Roof Insulation Minimum %" thick N/A N/A Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 2040 lbs./100 It'. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Composite insulation panels may be used as a top layer placed with the -polyisocyanurate side facing down. GAF requires either a ply of GAFGLAS' Stratavent® Perforated Venting Base Sheet laid dry or a layer of EnergyGuard'' Perlite Roof Insulation or wood fiber overlay board on all polyisocyanurate applications. Base Sheet: (Optional) Install one ply of GAFGLAS' #75 Base Sheet, Tri-Ply® #75 Base Sheet, GAFGLAS® #80 Ultima'" Base Sheet, Ruberoid® Mop Smooth, Ruberoid® Mop Smooth 1.5, Ruberoid® Mop Plus Smooth or Ruberoid® 20 Smooth, Ruberoid® HW Smooth or Ruberoid® HW 25 Smooth directly over the top layer of insulation. Adhere with any approved mopping asphalt applied within the EVT range and at a rate of 2040 lbs./sq. applied in accordance with manufacturer's instructions. (see General Limitation #4). OR GAFGLAS® Stratavent® Perforated Venting Base Sheet loose -laid dry (not for use with perlite top layer insulation or composite polyiso top layer insulation). Ply Sheet: One or more plies GAFGLAS® Ply 4, Tri-Ply' Ply 4, GAFGLAS® FlexPly'" 6 or GAFGLAS' #80 Ultima Base Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-401bs./sq. installed per manufacturer's installation instructions. Cap Sheet: (Optional) One ply of GAFGLAS' Mineral Surfaced Cap Sheet, Tri-Plyl BUR Granule Cap Sheet or GAFGLAS' EnergyCap' Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 2040 lbs./sq. installed per manufacturer's installation instructions. NOA No.: 18-0919.07 MAMMADE COUNTY Expiration Date: 11/04/23 FIX =sp Approval Date: 11/08/18 Page 9 of 27 Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. Topcoat® Membrane or Topcoat® Surface Seal SB applied at I to 1.5 gal./sq. OR Topcoat® MB Plus applied at 0.5 to 0.75 gal./sq.(to be used as a primer) followed by Topcoat® Membrane applied at 0.5 to 0.75 gal./sq. 3. Fiber Aluminum Roof Coating. Maximum Design Pressure: See Fastening Options. NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 10 of 27 Membrane Type: BUR Deck Type 1I: Wood, Insulated Deck Description: Min. 15/32" thick or greater plywood or wood plank secured 6 in. o.c. at panel end and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c. at max. System Type A(2): All insulation layers are adhered, to a mechanically attached anchor sheet. Membrane is subsequently fully adhered to insulation. All General and System Limitations shall apply. Fire Barrier: Topcoat® FireOut' Fire Barrier Coating, VersaShield® Fire -Resistant Slip Sheet or (optional) VersaShield® Solo' Fire -Resistant Slip Sheet installed per manufacturer's installation instructions. Anchor sheet: GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet, Ruberoid® 20 Smooth or GAFGLAS® Strataven& Venting Nailable Base Sheet is secured as described below. Fastening Miami -Dade County Approved min. 12 ga. Annular ring shank nails and min. 1-5/8 in. Option #1: diameter tin caps are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure: —45 psf. See General Limitation #7) Fastening Miami -Dade County Approved min. 12 ga. Annular ring shank nails and min. 1-5/8 in. Option #2: diameter tin caps are spaced 6 in. o.c. in the min 4 in. wide anchor sheet side laps and 6 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure: —52.5 psf. See General Limitation #7) Fastening Drill -Tee #14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill -Tee Option #3: AccuTrac® Flat Plates or Drill-Tec'' 3 in. Ribbed Galvalume Plate (Flat) are spaced 16 in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure: —52.5 psf. See General Limitation #7) Fastening Drill -Tee #14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill-Tec' Option #4: AccuTrac® Flat Plates or Drill -Tee' 3 in. Ribbed Galvalume Plate (Flat) are spaced 12 in. o.c. in the min 4 in. wide anchor sheet side laps and 12 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure: —60 psf. See General Limitation #7) Fastening Drill-Tec' #14 Fasteners and Drill-Tec"" 3 in. Standard Steel Plates, Drill-Tec"' Option #5: AccuTrac® Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in three staggered rows. (Maximum Design Pressure: —75 psf. See General Limitation #7) One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 EnergyGuard'" Polyiso Insulation, EnergyGuard' Tapered Polyiso Insulation, EnergyGuard' Ultra Polyiso Insulation, EnergyGuard"' RH Polyiso Insulation, EnergyGuard"' RH Tapered Polyiso Insulation Minimum 1" thick N/A N/A NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 11 of 27 Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft' EnergyGuard' Perlite Roof Insulation Minimum'/," thick N/A N/A Structodek® High Density Fiberboard Roof Insulation Minimum''%" thick N/A N/A Securock® Gypsum -Fiber Roof Board, DensDeck® Prime Roof Board Minimum''/<" thick N/A N/A Note: All insulation shall be adhered in a full mopping of approved hot asphalt within the EVT range and at a rate of 2040 lbs./100 ft'. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base Sheet (Optional): GAFGLAS® #75 Base Sheet, Tri-Ply' #75 Base Sheet, Ruberoid® 20 Smooth adhered in a full mopping of hot asphalt applied at 2040 lbs./sq. installed per manufacturer's installation instructions. Ply Sheet: When optional base sheet and/or cap sheet is present: Two or more plies of GAFGLAS® Ply 4, Tri-Ply® Ply 4, GAFGLAS® Flex Ply 6 adhered in a full mopping of hot asphalt applied at 20-40 lbs./sq. installed per manufacturer's installation instructions. When optional base sheet and/or cap sheet is not present: Three or more plies of GAFGLAS® Ply 4, Tri-Ply® Ply 4, GAFGLAS® Flex Ply 6 adhered in a full mopping of hot asphalt applied at 20-40 lbs./sq. installed per manufacturer's installation instructions. Cap Sheet (Optional): GAFGLAS® Mineral Surfaced Cap Sheet, Tri-Ply® BUR Granule Cap Sheet or GAFGLAS® EnergyCap' Mineral Surfaced Cap Sheet adhered in a full mopping of hot asphalt applied at 20 — 40 lbs./sq. installed per manufacturer's installation instructions. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. Topcoat® Membrane or Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq. OR Topcoat® MB Plus applied at 0.5 to 0.75 gal./sq.(to be used as a primer) followed by Topcoat® Membrane applied at 0.5 to 0.75 gal./sq. 3. Aluminum Fiber Roof Coating. Maximum Design Pressure: See fastening options above. MIAMWADE COUNTY ....T6 1 NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 12 of 27 Membrane Type: BUR Deck Type 11: Wood, Insulated Deck Description: Min. 15/32" thick or greater plywood or wood plank secured 6 in. o.c. at panel end and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c. at max. System Type A(3): All insulation layers are adhered, to a mechanically attached anchor sheet. Membrane is subsequently fully adhered to insulation. All General and System Limitations shall apply. Fire Barrier: Topcoato' FireOut' Fire Barrier Coating, VersaShield® Fire -Resistant Slip Sheet or (optional) VersaShield® Solo' Fire -Resistant Slip Sheet installed per manufacturer's installation instructions. Anchor sheet: GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet, Ruberoid® 20 Smooth or GAFGLAS® Stratavent® Venting Nailable Base Sheet is secured as described below. Fastening Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. 1-5/8 in. Option #1: diameter tin caps are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure: —45 psf. See General Limitation #7) Fastening Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. 1-5/8 in. Option #2: diameter tin caps are spaced 6 in. o.c. in the min 4 in. wide anchor sheet side laps and 6 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure. —52.5 psf. See General Limitation #7) Fastening Drill-Tec' #14 Fasteners and Drill-Tec"' 3 in. Standard Steel Plates, Drill-Tec' Option #3: AccuTrae Flat Plates or Drill -Tee 3 in. Ribbed Galvalume Plate (Flat) are spaced 16 in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure: —52.5 psf. See General Limitation #7) Fastening Drill-Tec' #14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill -Tee Option #4: AccuTrac® Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are spaced 12 in. o.c. in the min 4 in. wide anchor sheet side laps and 12 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure. —60 psf. See General Limitation #7) Fastening Drill -Tee #14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill -Tee Option #5: AccuTrac® Flat Plates or Drill -Tee' 3 in. Ribbed Galvalume Plate (Flat) are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in three staggered rows. (Maximum Design Pressure. —75 psf. See General Limitation #7) NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 13 of 27 One or more layers of any of the following insulations Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 EnergyGuard' Polyiso Insulation, EnergyGuard"' Tapered Polyiso Insulation, EnergyGuard"' Ultra Polyiso Insulation, EnergyGuard' RH Polyiso Insulation, EnergyGuard'' RH Tapered Polyiso Insulation Minimum 1" thick N/A N/A Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 EnergyGuard' Perlite Roof Insulation Minimum'/<" thick N/A N/A Structodek® High Density Fiberboard Roof Insulation Minimum''/:" thick N/A N/A Securock® Gypsum -Fiber Roof Board, DensDeck' Prime Roof Board Minimum'/4" thick N/A N/A Note: All insulation shall be adhered in a full mopping of approved hot asphalt within the EVT range and at a rate of 2040 lbs./100 It. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base Sheet: Ruberoid' 20 Smooth adhered in a full mopping of hot asphalt applied at 20401bs./sq. Cap Sheet: GAFGLAS' Mineral Surfaced Cap Sheet, Tri-Ply' BUR Granule Cap Sheet or GAFGLAS' EnergyCap' Mineral Surfaced Cap Sheet adhered in a full mopping of hot asphalt applied at 20 — 40 lbs./sq. installed per manufacturer's installation instructions. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. Topcoat' Membrane or Topcoat' Surface Seal SB applied at 1 to 1.5 gal./sq. OR Topcoat' MB Plus applied at 0.5 to 0.75 gal./sq.(to be used as a primer) followed by Topcoat' Membrane applied at 0.5 to 0.75 gal./sq. 3. Aluminum Fiber Roof Coating. Maximum Design Pressure: See fastening options above. NOA No.: 18-0919.07 MLA nonne counm Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 14 of 27 Membrane Type: BUR Deck Type 1I: Wood, Insulated Deck Description: Min. 15/32" thick or greater plywood or wood plank secured 6 in. o.c. at panel end and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c. at max. System Type A(4): All insulation layers are adhered, to a mechanically attached anchor sheet. Membrane is subsequently fully adhered to insulation. All General and System Limitations shall apply. Fire Barrier: TOPCOAT FireOut"' Fire Barrier Coating, VersaShield' Fire -Resistant Slip Sheet or (optional) VersaShield® Solo' Fire -Resistant Slip Sheet installed per manufacturer's installation instructions. Anchor sheet: GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet, Ruberoid® 20 Smooth or GAFGLAS® Stratavent® Venting Nailable Base Sheet is secured as described below. Fastening Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. 1-5/8 in. Option #1: diameter tin caps are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure: —45 psf. See General Limitation #7) Fastening Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. 1-5/8 in. Option #2: diameter tin caps are spaced 6 in. o.c. in the min 4 in. wide anchor sheet side laps and 6 in. o.c. in the Feld of the sheet in two staggered rows. (Maximum Design Pressure. —52.5 psf. See General Limitation #7) Fastening Drill-Tec' #14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill-Tec' Option #3: AccuTrac® Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are spaced 16 in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure. —52.5 psf. See General Limitation #7) Fastening Drill-Tec"' #14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill-Tec' Option #4: AccuTrac® Flat Plates or Drill-Tec"' 3 in. Ribbed Galvalume Plate (Flat) are spaced 12 in. o.c. in the min 4 in. wide anchor sheet side lap's and 12 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure. —60 psf. See General Limitation #7) Fastening Drill-Tec' #14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill-Tec' Option #5: AccuTrac® Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are spaced 8 in. o.c. in the'min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in three staggered rows. (Maximum Design Pressure. —82.5 psf. See General Limitation #7) NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 15 of 27 One or more layers of any of the following insulations. Insulation Layer Insulation Fasteners Fastener Density/ft, (Table 3) EnergyGuard'" Polyiso Insulation, EnergyGuard'" Tapered Polyiso Insulation, EnergyGuard" Ultra Polyiso Insulation, EnergyGuard' RH Polyiso Insulation, EnergyGuard' RH Tapered Polyiso Insulation Minimum 1" thick N/A N/A Note: All insulation shall be adhered in a full mopping of approved hot asphalt within the EVT range and at a rate of 2040 lbs./100 ft. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base Sheet: GAFGLAS® Stratavent® Perforated Venting Base Sheet is laid dry over the insulation. Ply Sheet: When optional cap sheet is present: Two or more plies of GAFGLAS® Ply 4, Tri-Ply® Ply 4, GAFGLAS® Flex Ply 6 adhered in a full mopping of hot asphalt applied at 2040 lbs./sq. installed per manufacturer's installation instructions. When optional cap sheet is not present: Three or more plies of GAFGLAS® Ply 4, Tri-Ply® Ply 4, GAFGLAS® Flex Ply 6 adhered in a full mopping of hot asphalt applied at 20401bs./sq. installed per manufacturer's installation instructions. Cap Sheet (Optional): GAFGLAS® Mineral Surfaced Cap Sheet, Tri-Ply® BUR Granule Cap Sheet or GAFGLAS® EnergyCap' Mineral Surfaced Cap Sheet adhered in a full mopping of hot asphalt applied at 20 — 401bs./sq. installed per manufacturer's installation instructions. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. Topcoat" Membrane or Topcoat® Surface Seal SB applied at I to 1.5 gal./sq. OR Topcoat® MB Plus applied at 0.5 to 0.75 gal./sq.(to be used as a primer) followed by Topcoat® Membrane applied at 0.5 to 0.75 gal./sq. 3. Aluminum Fiber Roof Coating. Maximum Design Pressure: See fastening options above. NOA No.: 18-0919.07 MuAMI•D,00e COUNTY Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 16 of 27 Membrane Type: BUR Deck Type II: Wood, Insulated Deck Description: 19/32" thick or greater or greater plywood or wood plank secured 6 in. o.c. at panel end and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c. at max. System Type A(5): All insulation layers are adhered, to a mechanically attached anchor sheet. Membrane is subsequently fully adhered to insulation. All General and System Limitations shall apply. Fire Barrier: FireOut' Fire Barrier Coating, VersaShield® Fire -Resistant Slip Sheet or VersaShield® (optional) Solo' Fire -Resistant Slip Sheet. Anchor sheet: GAFGLAS® #75 Base Sheet or Tri-Ply® #75 Base Sheet is secured as described below with Dade County Approved min. 12 ga. galvanized ring shank nails and 32 ga., 1-5/8 in. diameter tin tabs. Fastening: Nails and tabs are spaced 8 in. o.c. in the 4 in. wide side lap and 8 in. o.c. in two staggered rows in the field of the sheet. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft' EnergyGuard" Polyiso Insulation, EnergyGuard' Tapered Polyiso Insulation, EnergyGuard' RH Polyiso Insulation, EnergyGuard' RH Tapered Polyiso Insulation Minimum 1" thick N/A N/A Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ftz Structodek® High Density Fiberboard Roof Insulation, Securock® Gypsum -Fiber Roof Board Minimum''/:" thick N/A N/A Note: All insulation shall be adhered in a full mopping of approved hot asphalt within the EVT range and at a rate of 2040 lbs.1100 fe. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base Ply: Two or more plies of GAFGLASO FlexPly'" 6 adhered with hot asphalt applied at 20-25 lbs./sq. Cap Ply: GAFGLAS® Mineral Surfaced Cap Sheet adhered with hot asphalt applied at 20-25 lbs./sq. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. Topcoat® Membrane or Topcoat® Surface Seal SB applied at I to 1.5 gal./sq. OR Topcoat® MB Plus applied at 0.5 to 0.75 gal./sq.(to be used as a primer) followed by Topcoat® Membrane applied at 0.5 to 0.75 gal./sq. Maximum Design Pressure: —52.5 psf. (See General Limitation #7) MAMMADE COUNTY Km 0 NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 17 of 27 Membrane Type: BUR Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater thick or greater plywood or wood plank secured 6 in. o.c. at panel end and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c. at max. System Type C: All layers of insulation are mechanically attached to roof deck. Membrane is subsequently fully adhered to insulation. All General and System Limitations shall apply. Fire Barrier: FireOut' Fire Barrier Coating, VersaShield' Fire -Resistant Slip Sheet or VersaShield' (optional) Solo' Fire -Resistant Slip Sheet. One or more layers of any of the following insulations. Base Insulation Layer (Optional) Insulation Fasteners Fastener (Table 3) Density/ft' EnergyGuard' Polyiso Insulation, EnergyGuardd" RA Polyiso Insulation, EnergyGuard' RN Polyiso Insulation Minimum 1" thick N/A N/A Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density. Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. GAF requires either a ply of GAFGLAS' Stratavent' Perforated Venting Base Sheet laid dry or a layer of EnergyGuard' Perlite Roof Insulation or wood fiber overlay board on all polyisocyanurate applications. Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 SECUROCK' Gypsum -Fiber Roof Board Minimum '/" thick 2,8 1:1.78 ft' Base Ply: Two or more plies of GAFGLAS® FlexP1ym 6 adhered with hot asphalt applied at 20-25 lbs./sq. installed per manufacturer's installation instructions. Cap Ply: GAFGLAS'Mineral Surfaced Cap Sheet, Tri-Ply' BUR Granule Cap Sheet or GAFGLAS' EnergyCap' Mineral Surfaced Cap Sheet adhered with hot asphalt applied at 20-25 lbs./sq. installed per manufacturer's installation instructions Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 3001bs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. Topcoat' Membrane or Topcoat' Surface Seal SB applied at I to 1.5 gal./sq. OR Topcoat' ME Plus applied at 0.5 to 0.75 gal./sq.(to be used as a primer) followed by Topcoat' Membrane applied at 0.5 to 0.75 gal./sq. 3. Fiber Aluminum Roof Coating. Maximum Design Pressure: —60 psE (See General Limitation #7) NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 18 of 27 Membrane Type: BUR Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank secured 6 in. o.c. at panel end and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c. at max. System Type D: All insulation is loose laid with preliminary attachment to roof deck. Anchor sheet is subsequently mechanically fastened through insulation to the roof deck. All General and System Limitations shall apply. One or more layers of any of the following insulations Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft' EnergyGuard' Polyiso Insulation, EnergyGuard'" Ultra Polyiso Insulation, EnergyGuard'" RA Polyiso Insulation Minimum 1.3" thick N/A N/A Structodek® High Density Fiber Board Minimum 1" thick N/A N/A Note: Insulation shall have preliminary attachment, prior to the installation of the base sheet, at a minimum application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft., and four fasteners for any insulation board having no dimension greater than 8 ft. All layers of insulation, optional thermal barrier (when present) and base sheet shall be simultaneously fastened. See base sheet below for fasteners and density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Fire Barrier: FireOut' Fire Barrier Coating, VersaShield® Fire Resistant Roof Deck Protection, (optional) VersaShield® Solo"' Fire -Resistant Slip Sheet, DensDeck® Roof Board, Securock' Glass - Mat Roof Board or Securock' Gypsum Fiber Roof Board. Base Sheet: Install one ply of GAFGLAS® #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS® #80 Ultima'" Base Sheet, GAFGLAS® Stratavent® Nailable Venting Base Sheet or Ruberoid® 20 Smooth applied over the loose laid insulation with 2" side laps mechanically fastened as described below; Fastening Drill-Tec"' 412 Fastener or Drill-Tec'" #14 Fastener and Drill-Tec"' 3" Steel Plate, Drill - Option #1: Tec 3 in. Ribbed Galvalume Plate (Flat), Drill-Tec"" AccuTrac® Flat Plate or Drill-Tec"' AccuTrac® Recessed Plate is installed through the base sheet and insulation in 3 rows 12" o.c. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the sheet. (Maximum Design Pressure —45 psf. See General Limitation #9) Fastening Drill-Tec' #12 Fastener or Drill-Tec'" #14 Fastener and Drill-Tec"" 3" Steel Plate, Drill - Option #2: Tec 3 in. Ribbed Galvalume Plate (Flat), Drill-Tec"" AccuTrac® Flat Plate or Drill-Tec" AccuTrac® Recessed Plate is installed through the base sheet and insulation in 4 rows 8" o.c. One row is in the 2" side lap. The other 3 rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —75 psf. See General Limitation #9) Fastening GAFGLAS® #80 Ultimam Base Sheet, Ruberoid® 20 Smooth, Ruberoid® Mop Smooth Option #3: attached to deck with approved annular ring shank nails with a minimum embedment of 1" into the wood substrate and inverted 3" steel plate at a fastener spacing of 9" o.c. at the 4" lap and in two rows staggered with a fastener spacing of 9" o.c. in the center of the membrane. Not for use with DensDeck or Securock Fire Barrier (Maximum Design Pressure —60 psf. See General Limitation #7) NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/19 Page 19 of 27 Fastening (Continued) Drill-Tec' #12 Fastener or Drill -Tee #14 Fastener and Drill-Tec'° 3" Steel Plate, Drill - Option #4: Tee 3 in. Ribbed Galvalume Plate (Flat), Drill-Tec' AccuTrac® Flat Plate or Drill-Tec'' AccuTrac® Recessed Plate in 4 rows 12" o.c. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —60 psf. See General Limitation 99) Ply Sheet: One or more plies of GAFGLAS® Ply 4, Tri-Ply® Ply 4, GAFGLAS® F1exPly' 6 or GAFGLAS® #80 Ultima Base Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. installed per manufacturer's installation instructions. Cap Sheet: (Optional) One ply of GAFGLAS® Mineral Surfaced Cap Sheet, Tri-Ply BUR Granule Cap Sheet or GAFGLAS® EnergyCap' Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20401bs./sq. installed per manufacturer's installation instructions. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. Topcoat® Membrane or Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq. OR Topcoat® MB Plus applied at 0.5 to 0.75 gal./sq.(to be used as a primer) followed by Topcoat® Membrane applied at 0.5 to 0.75 gal./sq. 3. Fiber Aluminum Roof Coating. Maximum Design Pressure: See Fastening Options NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 20 of 27 n r : `per on=msu a e Deck Description: 19/32" or greater plywood or wood plank decks secured 6 in. o.c. at panel end and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c. at max. System Type E(1): Anchor sheet mechanically attached to roof deck. All General and System Limitations shall apply. Fire Barrier: Topcoat® FireOut' Fire Barrier Coating, VersaShield® Fire Resistant Roof Deck (optional) Protection, VersaShield® Solo'"' Fire -Resistant Slip Sheet installed per manufacturer's installation instructions. Base sheet: GAFGLAS® #80 Ultima`" Base Sheet, Stratavent® Nailable Venting Base Sheet, Ruberoid® 20 Smooth, Ruberoid® SBS Heat -Weld" Smooth or Ruberoid® SBS Heat -Weld' 25 base sheet mechanically fastened to deck as described below; ffiastening ase e n of ptio nc he ttache dec w� ppreve n rin h ' Fastening Option #2: Surfacing: Maximum Design Pressure: Design Pressure —52.5 psf. See General Limitation #7) GAFGLAS® #80 Ultimate' Base Sheet, Ruberoid® 20 Smooth or Ruberoid® Mop Smooth attached to deck with approved 1 %d' annular ring shank nails and inverted 3" steel plate at a fastener spacing of 9" o.c. at the 4" lap and in two rows staggered with a fastener spacing of 9" o.c, in the center of the membrane. (Maximum Design Pressure —60 psf. See General Limitation #7) Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. Topcoat® Membrane or Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq. OR Topcoat® MB Plus applied at 0.5 to 0.75 gal./sq.(to be used as a primer) followed by Topcoat' Membrane applied at 0.5 to 0.75 gal./sq. 3. Fiber Aluminum Roof Coating. See Fastening Options NOA No.: 18-09 9.0V Mwni•onoecournr x i Kation Date: 1 4/2 1 ... � � A 1 tL(IS/ ag o Membrane Type: BUR Deck Type 1: Wood, Non -insulated Deck Description: 19/32" or greater plywood or wood plank decks secured 6 in. o.c. at panel end and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c. at max. System Type E(2): Anchor sheet mechanically attached to roof deck. All General and System Limitations shall apply. Fire Barrier: Topcoat® FireOut'' Fire Barrier Coating, VersaShield®Fire Resistant Roof Deck (optional) Protection, VersaShield® Solo' Fire -Resistant Slip Sheet installed per manufacturer's installation instructions. Anchor sheet: GAFGLAS® #80 Ultima Base Sheet mechanically attached with Miami -Dade County Approved min. 1'/4 long, 12 ga., annular ring shank nails and 1-5/8" diameter tin caps spaced 7" o.c. in the min 4" wide side laps and in 3 staggered rows in the field of the sheet. Ply Sheet: Two or more plies of GAFGLAS® Ply 4, Tri-Plyl Ply 4, GAFGLAS® FlexPly" 6 adhered to the base sheet in full mopping of approved asphalt applied within the EVT range and at a rate of 2040 lbs./sq. installed per manufacturer's installation instructions. Cap Sheet: One ply of GAFGLASO Mineral Surfaced Cap Sheet, Tri-Ply® BUR Granule Cap Sheet or GAFGLASO EnergyCapTM Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 2040 lbs./sq. installed per manufacturer's installation instructions. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. Topcoat® Membrane or Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq. OR Topcoat® MB Plus applied at 0.5 to 0.75 gal./sq.(to be used as a primer) followed by Topcoat® Membrane applied at 0.5 to 0.75 gal./sq. Maximum Design Pressure: -82.5 psf. (See General Limitation #7) MIAMI•DADE COUNTY .... I NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 22 of 27 Membrane Type: BUR Deck Type 1I: Wood, Non Insulated Deck Description: Min. 15/32" thick or greater plywood or wood plank secured 6 in. o.c. at panel end and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c. at max. System Type E(3): Anchor sheet mechanically attached to roof deck. All General and System Limitations shall apply. Fire Barrier: TOPCOAT FireOut' Fire Barrier Coating, VersaShield® Fire -Resistant Slip Sheet or (optional) VersaShield® Solo'I Fire -Resistant Slip Sheet installed per manufacturer's installation instructions. Anchor sheet: GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet, Ruberoid® 20 Smooth or GAFGLAS® Stratavent® Venting Nailable Base Sheet is secured as described below. Fastening Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. 1-5/8 in. Option #1: diameter tin caps are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure: —45 psf. See General Limitation 97) Fastening Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. 1-5/8 in. Option #2: diameter tin caps are spaced 6 in. o.c. in the min 4 in. wide anchor sheet side laps and 6 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure: —52.5 psf. See General Limitation #7) Fastening Drill -Tee' #14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill -Tee' Option #3: AceuTrac® Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are spaced 16 in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure: —52.5 psf. See General Limitation #7) Fastening Drill-Tec7 914 Fasteners and Drill-Tec'°' 3 in. Standard Steel Plates, Drill -Tee Option #4: AccuTrac® Flat Plates or Drill -Tee 3 in. Ribbed Galvalume Plate (Flat) are spaced 12 in. o.c. in the min 4 in. wide anchor sheet side laps and 12 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure: —60 psf. See General Limitation #7) Fastening Drill-Tec' #14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill-Tec' Option #5: AccuTrac® Flat Plates or Drill-Tec'" 3 in. Ribbed Galvalume Plate (Flat) are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in, o.c. in the field of the sheet in three staggered rows. (Maximum Design Pressure: —97.5 psf. See General Limitation #7) Ply Sheet: When optional cap sheet is present: Two or more plies of GAFGLAS® Ply 4, Tri-Ply® Ply 4, GAFGLAS® Flex Ply 6 adhered in a full mopping of hot asphalt applied at 2040 lbs./sq. installed per manufacturer's installation instructions. When optional cap sheet is not present: Three or more plies of GAFGLAS® Ply 4, Tri-Ply® Ply 4, GAFGLAS® Flex Ply 6 adhered in a full mopping of hot asphalt applied at 2040 lbs./sq. installed per manufacturer's installation instructions. NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 23 of 27 Cap Sheet: (Optional) GAFGLAS® Mineral Surfaced Cap Sheet, Tri-Ply® BUR Granule Cap Sheet or GAFGLAS EnergyCap' Mineral Surfaced Cap Sheet adhered in a full mopping of hot asphalt applied at 20 — 40 lbs./sq. installed per manufacturer's installation instructions. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 4001bs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. Topcoat® Membrane or Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq. OR Topcoat® MB Plus applied at 0.5 to 0.75 gal./sq.(to be used as a primer) followed by Topcoat® Membrane applied at 0.5 to 0.75 gal./sq. 3. Fiber Aluminum Roof Coating. Maximum Design Pressure: See Fastening Above. NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 24 of 27 Membrane Type: BUR Deck Type II: Wood, Non Insulated Deck Description: Min. 15/32" thick or greater plywood or wood plank secured 6 in. o.c. at panel end and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c. at max. System Type E(4): Anchor sheet mechanically attached to roof deck - All General and System Limitations shall apply. Fire Barrier: TOPCOAT FireOuf" Fire Barrier Coating, VersaShield® Fire -Resistant Slip Sheet (optional) VersaShield® Solo' Fire -Resistant Slip Sheet, installed per manufacturer's installation instructions. Anchor sheet: GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet, Ruberoid® 20 Smooth or GAFGLAS® Stratavent® Venting Nailable Base Sheet is secured as described below. Fastening Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. 1-5/8 in. diameter Option #1: tin caps are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c, in the field of the sheet in two staggered rows. (Maximum Design Pressure. —45 psf. See General Limitation #7) Fastening Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. 1-5/8 in. diameter Option #2: tin caps are spaced 6 in. o.c. in the min 4 in. wide anchor sheet side laps and 6 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure: —52.5 psf. See General Limitation #7) Fastening Drill-Tec'" #14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill-Tec' AccuTrac' Option #3: Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are spaced 16 in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure. —52.5 psf. See General Limitation #7) Fastening Drill -Tee #14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill-Tec' AccuTrace Option #4: Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are spaced 12 in. o.c. in the min 4 in. wide anchor sheet side laps and 12 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure: —60 psf. See General Limitation 97) Fastening Drill-Tec' #14 Fasteners and Drill -Tee' 3 in. Standard Steel Plates, Drill-Tec' AccuTrac® Option #5: Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in three staggered rows. (Maximum Design Pressure: —97.5 psf. See General Limitation #7) Base Sheet: Ruberoid® 20 Smooth adhered in a full mopping of hot asphalt applied at 20-40 lbs./sq. installed per manufacturer's installation instructions. Cap Sheet: GAFGLAS® Mineral Surfaced Cap Sheet, Tri-Ply® BUR Granule Cap Sheet or GAFGLAS EnergyCap' Mineral Surfaced Cap Sheet adhered in a full mopping of hot asphalt applied at 20 — 40 lbs./sq. installed per manufacturer's installation instructions. NOA No.: 18-0919.07 VN M"PDAD: COUNTY Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 25 of 27 Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. Topcoat® Membrane or Topcoat® Surface Seal SB applied at Ito 1.5 gal./sq. OR Topcoat® MB Plus applied at 0.5 to 0.75 gal./sq.(to be used as a primer) followed by Topcoat® Membrane applied at 0.5 to 0.75 gal./sq. 3. Aluminum Fiber Roof Coating. Maximum Design Pressure: See Fastening Above. NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 26 of 27 WOOD DECK SYSTEM LIMITATIONS: 1 A slip sheet is required with GAFGLAS® Ply 4 and GAFGLAS® Flex Ply' 6 when used as a mechanically fastened base or anchor sheet. 1 2. Minimum %<" DensDecle" Roof Board or %:" Type X gypsum board is acceptable to be installed directly over the wood deck. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 2040 lbs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each sidelap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of 45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 2751bf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Professional Engineer, Registered Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and comer areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS I I 1 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and comers). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and comers). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. END OF TMS ACCEPTANCE NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 27 of 27