Loading...
HomeMy WebLinkAboutEVALUATION REPORT�I CREEK Certificate of Authorization bur 29824 SCANN�+(�/tI�II�' 17520 Edinburgh Drive ED Tampa, FL 33647 TECHNICAL SERVICES, LLC BY (813) 480-3421 St. Lud9County EVALUATION REPORT FLORIDA BUILDING CODE, 6'" EDITION (2017) Manufacturer. Quality Assurance: SCOPE TAMKO BUILDING PRODUCTS, INC. Issued October 19, 2017 P.O. Box 1404 - Joplin, MO 64802 (417) 624.6644 htp://www.lamko.com UL LLC (QUA9525) Category: Roofing Subcategory: Undedayments Code Sections: 1507.1.1 Properties: Physical properties PRODUCT DESCRIPTION TAMKO® ASTM Slate ASTM D 6380, Class M, Type II undedayment constructed from organic felt saturated Surfaced Roll Roofing with asphalt and coated on both sides with asphalt and surfaced with granules. TAMKO® ASTM Tile ASTM D 6380, Class M. Type II undedayment constructed from an organic felt saturated Underlayment with asphalt then coated on both sides with asphalt and surfaced with granules. TAMKO® Master ASTM D 6380, Class S, Type IV undedayment constructed from an organic felt saturated Smooth with asphalt then coated on both sides with asphalt and surfaced with a fine mineral. For use in non-HVHZ only. TAMKOO Moisture Self -adhered, ASTM D 1970, fiberglass reinforced, modified bitumen sheet membrane Guard® with a mineral surfacing and a removable release film an the adhesive side and removable selvedge release tape. TAMKO® No.16 ASTM ASTM D 226, Type I undedayment constructed from a non -perforated organic felt that is Asphalt Saturated saturated with asphalt Organic Felt TAMKO® No.15 UL ASTM D 226, Type I undedayment constructed from a non -perforated organic felt that is Asphalt Saturated saturated with asphalt. Organic Felt TAMKO® No. 30 ASTM ASTM D 226, Type 11 underlayment constructed from a non -perforated organic felt that is Asphalt Saturated saturated with asphalt Organic Felt ' TAMKO® No. 30 UL ASTM D 226, Type 11 undedayment constructed from a non -perforated organic felt that is Asphalt Saturated saturated with asphalt. Organic felt TAMKOB TW Metal and Self -adhered, flexible, ASTM D 1970 and TAS 103, rubberized asphalt sheet membrane Tile Underlayment with a polymer film on the surface and a removable release film on the adhesive side. TAMKO®TW Self -adhered, flexible, ASTM D 1970, rubberized asphalt sheet membrane with a Underlayment polymer film on the surface and a removable release film on the adhesive side. 1 of 4 Technical Services, LLC of arty product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed heroin. CREEK TAMKO BUILDING PRODCUTS, INC. TAMKO Underlayments TECHNICAL SERVICES, LLC TAMKO@) TAM -FELT Alternate to ASTM D 226, Type I and Type II underlayment constructed from a non - perforated organic felt that is saturated with asphalt. APPLICATION METHOD Installation shall be in accordance with the published.manufacturees installation instructions, the FBC, and the requirements below. Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to undedayment application. The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Plywood deck shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1/8' gap at abutting joints. The minimum application temperature shall be 50OF except as follows: a) The minimum application temperature of TAMKO® TW Metal and Tile Undedayment and TAMKO® TW Undedayment shall be 40T. b) The minimum application temperature of TAMKO® Moisture Guard® shall be 35°F. The minimum roof slope shall be in accordance with FBC requirements except as follows: a) The minimum slope of TAMKO®ASTM Slate Surfaced Roll Roofing shall be 2:12. Underlayments shall be exposed in accordance with the manufacturer's recommendations, but in no case shall exposure exceed 30 days. Exception., TAMKOO TW Metal and Tile Underlayment may be exposed for a maximum 90 days. Self -adhering undedayments may be adhered to primed or unprimed plywood substrates in the non-HVHZ. All roof coverings shall be mechanically fastened through the undedayment to the roof deck. Allowable Roof Coverings: - Metal Roof:.: Mirnrel :. Wood. -s16te AeDhatt _Panob and " Surfaced Roit.f Shinalea ono ^'" 'Clay and, Underla inept Shin ies : 8hln lea Roofl s = -Shake® _"" _Shin less Concrete Tile, TAMKOO ASTM Slate Surfaced Roll Roofing Y, N N N N Y TAMKOO ASTM Tile Underlayment N N N N N Y TAMKO® Master Smooth Y' N N N N N TAMKO® Moisture Guard® Y N N N N N TAMKO0No.1S ASTM Asphalt Saturated Organic Y Y Y Y2 N N Felt TAMKO© No. 15 UL Asphalt Y Y Y Saturated Organic Felt Yr Y N TAMKOV No. 30 ASTM Asphalt Saturated Organic Y Y Y Y Y Y Felt TAMKO® No. 30 UL Asphalt Saturated Organic Felt Y Y Y N Y N TAMKO®TW Metal and Tile Y Y N Underlayment N N Y TAMKO®TW Undedayment Y Y N N N N TAMKO®TAM-FELT Y N N N N N ,rules. it Gpen vairey appucauons per iou(.z.s.z 2) Wood shingles only i or rvuu I.Y t-L12328-RB Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20.3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. i CREEK TECHNICAL SERVICES, LLC LIM(TATIONs TAMKO BUILDING PRODCUTS, INC. TAMKO Underlayments 1) Fire Classification is not within the scope of this evaluation. 2) Wind uplift resistance in not within scope of this evaluation. 3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. „ 4j Contact the manufacturer when installing at temperatures below the minimum application temperature. 5) Unless otherwise stated, the minimum roof slope shall be in accordance with FBC requirements. 6) All underlayments shall be installed with the roll length parallel to the Save, starting at the eave, and lapped in successive courses installed up the deck in a manner that effectively sheds water from the deck. End laps shall be staggered between courses in accordance with the manufacturer's application instructions. 7) The underlayment maybe used as described in other current FBC product approval documents. 8) The underlayment shall not be installed over existing roof coverings. 9) Contact the manufacturer regarding specific exposure limits for each underlayment. 10) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 51G20-3. REFERENCES Eni PRI Construction Materials PRI Construction Materials PRI Construction Materials PRI Construction Materials PRI Construction Materials PRI Construction Materials PRI Construction Materials PRI Construction Materials PRI Construction Materials PRI Construction Materials PRI Construction Materials Reoort No. TAP-192-02-01 TAP-193-02-01 TAP-214-02-01 TAP-21502-01 TAP-216-02-03 TAP-217-02-01REV TAP-218-02-01 TAP-219-02-01 TAP-220-02-01 TAP-222-02-01 TAP-245-02-01 PRI Construction Materials Technologies (TST6049) TAP-311-02-01 PRI Construction Materials Technologies (TST6049) TAP-319-02-01.1 PRI Construction Materials Technologies (TST6049) TAP-387-02-01 PRI Construction Materials Technologies (TST6049) TAP-388-02-01 UL LLC (TST9628) 13CA12269 Standard ASTM D 1970 ASTM D 1970 ASTM D 4869 ASTM D 226 ASTM D 6380 ASTM D 6380 ASTM D 226 ASTM D 226 ASTM D 6380 ASTM D 4869 TAS 103 ASTM D 4798 ASTM D 1970 ACC 188 ASTM D 1970 ASTM D 1970 ASTM D 226 Year 2015a 2015a 2016 2009 2003(2013) 2003(2013) 2009 2009 2003(2013) 2016 1995 2011 2015a 2012 20153 20153 2009 TBP14001.4 FL12328-Ra Page 3 of 4 This evaluation report Is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shag notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, Installation, recommended use, or other product attributes that are not specifically addressed herein. TAMKO BUILDING DING PRODCUTS, INC. TAMKO Underlayments TECHNICAL SERVICES, LLC COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 6s' Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. p`t1Y 'R„Pr�41t .� GAP No 74021 0: STA7E —F :�<C/ •c� O R 1 O P UNQ,� 1ONA� CERTIFICATION OF INDEPENDENCE 2017.1-0:19 12:15:58 04'00' Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest In any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest P.E. does not have, nor will acquire, a financial Interest in any other entity involved in the approval process of the product END OF REPORT r or iguu ev hL1Z3Z5-K8 Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.