HomeMy WebLinkAboutREVISION - BUILDING PERMIT. '--PA
OFFICE USE ONLY:
DATE FILED: _
REVISION FEE:
PERMIT # 1603-0341
RECEIPT #
PLANNING & DEVELOPMENT SERVICES
BUILDING & CODE REGULATION DIVISION
2300 VIRGINIA AVENUE
FORT PIERCE, FL 34982-5652
(772) 462-1553 FAX (772) 462-1578
APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
1. LOCATION/
ADDRESS: 'RILLAS DEL NORTE
2. DETAILED DESCRIPTION OF PROJECT
REVISIONS:
REVISED ENERGY CALCS
3. CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #: ST. LVCIE COUNTY CERT. #: 8898
BUSINESS NAME: Corpora ion
QUALIFIERS N WOO South US-HSuite 2
ADDRESS: 8UU wy.
CITY; Fort St. LUcie ST
PHONE (DAYTIME): M-
4. OWNERBUH.DER INFORMATION:
NAME: Wynne Building Corporation
ADDRESS: 8000 SouthHwy. I Suite
CITY:
PHONE: (772) 878-5513
5. ARCHITECT/ENGINEER INFORMATION:
NAME: BRADEN & BRADEN
ADDRESS:
CITY: STUART
PHONE (DAYTIME): (772) 287-8258
Revised 07/22f2014
TE:
FAX:
ZIP: "ZI
772 7 -7 6
FAX:
FAX:
ZIP:
ZIP:
FILE Copy
FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION.
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: THE GRAND CARLTON
Builder Name: ST. LUCIE COUNTY 13L1I-DL\G DIVISION ,
Street: SPANISH LAKES
Perms Office: RE1 IEWED FOR CO
L NIA„ CE A
City, State, Zip: FT. PI�F , FL ,
Permit NumbergEVIE%VTi MY
Owner. v\�f�`S���
Jurisdiction: DATE N J$
RMIT NIU5 i
Design Location: Location: FL Fort Pierce
PLANS 1'
E ODE
1. New construction or existing New (From Plans)
9. Wall Types(1712.0 sgft.)
Insulation Area
2. Single family or multiple family Single-family
Concrete Block - Int Insult Exterior
R=4.1 1312.00 IF
b. Frame - Wood, Adjacent
b.
R=11.0 400.00 112
. 3. Number of units, If multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 2
d. N/A
R= IF
10. Ceiling Types (1720.0 sgft.)
Insulation Area
5. Is this a worst case? Yes
a. Under Attic (Vented)
R=30.0 1720.00 ft2
6. Conditioned floor areaabove grade (112) 1720
b. WA
R= ft2
c. WA
R= ift
Conditioned floor area below grade (ft2) 0
11. Ducts
R ft2
7. Windows(141.3 sgft.) Description Area
a. Sup: Attic, Rat Attic, AH: Attic
6 147
a. U-Factor. Sgl, U=0.50 141.25 ft2
SHGC: SHGC=0.25
f12
12. Cooling systems
kBtu/hr Efficiency
b. U-Factor. WA
a. Central Unit
34.8 SEER.15.00
SHGC:
c. U-Factor. WA ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor.. N/A ft2
a. Electric Heat Pump
35.0 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.699 ft.
Area Weighted Average SHGC: 0.250
14. Hot water systems
a. Electric
Cap: 40gallons
8. Floor Types �(1720.0 sgft.) Insulation Area
EF: 0.920
a. Slab -On -Grade Edge Insulation R=0.0 - 1720.00112
b. Conservation features
b. WA R= 112
None
a WA R= fP
15. Credits
Patel
0:082 Total Proposed Modified Loads: 43.30
PASS
Glass/FloorArea
Total Baseline Loads: 43.30
1 hereby certify that the plans and specifications covered by
Review of the plans and
OVgHE Sr4. �
this calculation are in compliance with the Florida Energy
specificationscovered by this
Code.
calculation indicates compliance
��
with the Florida Energy Code.
f,+nr"- .r,°'• °
PREPARED Y: _
Before construction is completed
DATE: -
this building will be inspected for
_
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
OD WE
OWNER/ G -(-
BUILDING OFFICIAL:
DATE:
DATE:
_1.
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.2.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.AEVISION
6/21I201611:18:AM EnergyGauge® USA -FlaRes2014 Section R405.4.1.Compliant Software C�p 9e 1 of 4
hL)KM 1141.10-ZV 4 ..
PROJECT
Title:
THE GRAND CARLTON Bedrooms:. 2
Address Type: Street Address
Building Type:
User
Conditioned Area: 1720
Lot #
Owner
Total Stories: 1
Block/SubDivision:
# of Units:
1
Worst Case: Yes
PlatBook:
Builder Name:
Rotate Angle: 135
Street: SPANISH LAKES
Pemift Office:
Cross Ventilation:
County: ST. LUCIE COUNTY
Jurisdiction:
Whole House Fan:
City, State, Zip: FT. PIERCE,
Family Type:
Single-family
FL,
New/Existing:
New (From Plans)
Comment:
CLIMATE
IECC Design Temp
Int Design Temp Heating Design Daily Temp
Design Location
TMY Site Zone. -97.5 % 2.6%
Winter
Summer Degree Days Moisture Range
FL, Fort Pierce Ft. ST_LUCIE_CO—INTL 2 39 90
70
75 722 62 Low
BLOCKS
Number
Name
Area Volume
1
BlockT
1720 13760
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled Heated
1
Main
1720 13760 Yes 4
2
1 Yes Yes Yes
FLOORS
#
Floor Type
Space .Perimeter R-Value
Area
Tile Wood Carpet:
1 Slab -On -Grade Edge Insulatio Main 187 ft 0
1720 ft'
— 1 0 0
ROOF
Roof Gable Roof
Solar
SA Emitt Emitt Deck Pitch
Tested insul. (deg)
#
Type
Materials Area Area Color
Absor.
Tested
1
Hip
Metal- 1813'fP Oft' Light
0.6
No 0.9 No 0 18:4-
ATTIC
J #
Type
Ventilation Vent Ratio (1 in)
Area
RSS IRCC
1
Full attic
Vented 300
1720 ft'
N N
CEILING
#
Ng Type
Space R-Value Area
Framing Frac Truss Type
1
--I
Under Attic (Vented)
Main 30 1720 h'
0.11 Wood
F/`FCOP,
61211201611:18 AM EnergyGougeO USA - FlaRes2014 SectionR405.4.1 Compliant Software Page 2 of 4.
FORM R405-2014
WALLS
1L#
Adjacent Cavity Width Height Sheathing Framing Solar Below
Dint Tc-_JNa0.1ype- Space 11-Value--E -In Et In araa.-. R- tau e_-ftcOan--Absor_-.Grade°1
_ 1
-2
-3
-4
5
N=>SE Exterior Concrete Block - Int Insul. Main
E=>SW Exterior Concrete. Block-.Int Insul Main
S=>NW Exterior Concrete Block- Int Insul Main
W=>NE Exterior Concrete Block - Int Insul Main
N=>SE Garage Frame - Wood Main
4.1 48 8
4.1 34 8
4.1 48 8
4.1 34 8
11 6o a.
384.0 ft=
272.0 IF
384.0 ft'
272.0 ft'
400.0 ft'
0 0.6
0 0.6
0 0.6
0 0.6
0 0.6
0
0
0
0
0
DOORS
# Omt Door Type Space
Storms
U-Value Width
Ft In
Height
Ft In
Area
1 S=>NW Insulated Main
None
.28 3
6 8
20 ft'
WINDOWS
Orientation shown is the entered orientation => cha
ed to Worst Case.
/
V
Wall
# Ornt ID Frame Panes NFRC
U-Factor SHGC
Overhang
Area Depth Separation_
Int Shade
Screening
_
_
_
_
1 N=>SE 1 Metal Single (Tinted) Yes
2 N=>SE 1 Metal Single (Tinted) Yes
3 E=>SW 2 Metal Single (Tinted) Yes
4 W=>NE 4 Metal Single (Tinted) Yes.
5 W=>NE 4 Metal Single(Tinted)Yes
6 W=>NE. 4 Metal- Single Mrited) Yes
0.5 025
0.5 0.25
0.5 0.25
0.5 0.25
0.5 0.25
0.5 0:25
27.0 ft' 2 It 0 in 1 ft 4 in
40.0 ft' 8 It 0 in 1 ft 4 in
39.8 ft' 2 ft 0 in 1 ft 4 in
13.5 ft' 2 It 0 in 1 ft 4 in
6.0 ft' 2 ft 0 in 1 It 4 in
15.0 ft' 2ft 0 in 1 ft 4 in
Drapesiblinds
Drapes/blinds
Drapesiblinds
Drapes/blinds
Drapes/blinds
Drapes/blinds
None
None-
None.
None
None
None
GARAGE
# Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height Exposed Wall Insulation
1 1040 ft' 1040 ft'
50 ft
8It
11
INFILTRATION
#
Scope Method SLA
CFM 50 ' ELA EgLA ACH ACH 50
1. Wholehouse Proposed ACH(50) .000254
1146.7 62.95 118.39. .1855.
-5
HEATING SYSTEM
# System Type Subtype
Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump None
HSPF:8.5
35 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type Subtype
Efficiency
Capacity AirFlowSHR
Block
Ducts
1 Central Unit None
SEER: 15 34.8 kBtu/hr 1044 cfm
0.85 1
sys#1
6/21/2016 11:18 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4
FORM R405-2014
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap Use
SetPnt
Conservation
1 ElectricT
None
Garage
0.92 40.gal 50gal
120deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert #
Company Name
System Model # Collector Model
# Area
Volume
FEF
None
None
fF
DUCTS
/
—Supply—
—Return
Air
CFM25
CFM25
HVAC#
V #
Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
QN RLF
Heat Cool
_ 1
Attic
6 147 fN
Attic
20 ft' Default Leakage
Attic
(Default) (Default)
1 1
TEMPERATURES
Programablee T]hermosta((t��Y
CApr eiling Fans:
Heat ng [X] Jan
[X] Feb
[[ ]]
[X] Mar
[[ jj
LJ
Apr
()()
Jun ]Jul
[X]
[ 1 Aug
[X1
I Sep
[ ]
LJ Oct
Nov
Dec
�(7(�] Dec
c
Venting [[ J) Jar
[[ 11 Feb
[[�X11Mar
ll�xll
[ .� May Jun )Jul
E
[ lAug
E 11 Sep
lxl
[ ]
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
.3
4 5 6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78 78 78
78
78
80
80
80
80
PM
80
80
78
78 78 78
78
78
78
78
78
78
Cooling(WEH)
AM
78
78
78
78 78 78
78
78
78
78
78
78
PM
78
78
78
78 78 78
78
78
78
78
78
78
Healing (WD)
8
68 68 68
68
8
68
68
66
66-
PM
68
68
Heating (WEH)
AM
66
66
66
.661 66 68
68
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68..
66
66
612V201611:18 AM EnergyGauge®USA - FlaRes2014 Section R405.4.1 Compliant Software
/1'r
Cppy
Page 4 of 4
FORM R405-2014
TABLE.. 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: THE GRAND CARLTON Builder Name:
Street SPANISH LAKES Permit Office:
City,. State,: Zip: Fr. PIERCE, FL,, Permit Number.
Owner. Jurisdiction:.
Design Location: FL, Fort Pierce
COMPONENT
CRITERIA
CHECK
Air barrier and thermal barrier
A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks'orjoints in the air barrier shall be sealed.
Air -permeable insulation shall not be used as a sealing material.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps inthe air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Comers and headers shall be insulated andthejunction of the foundation
Walls
and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the airbarrier.
Knee walls shall be sealed.
Windows, skylights and doors -
The space between window/door jambs,and framing and skylights and
framing shall be sealed.
Rim''oists
Rim joists are insulated and include an air barrier.
Floors (including above -garage
Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors)
of subfloor decking.
The air barrier shall be installed atany exposed edge of insulation.
Crawl space walls
Where provided in lieu of floor insulation, insulation.shall be permanently'
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered wither Class I
vapor retarder with overlapping, joints taped.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities
Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall be
airtight, IC rated, and sealed to the drywall.
Plumbing and wiring
Battinsulation shall be cut neatly to -fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to available
Apace shall extend: behind piping and wiring.
Shower/tub on exterior wall
Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
EleetricaUphone box on
The air barrier shall be installed' behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall b
sealed to the sub -floor ordrywall.
Fireplace
An air barrier shall be installed on fireplace walls. Fireplaces shallhave
gasketed doors
6/21/2016 11:1S AM EnergyGaugeO USA- FlaRes2014 Section R405.4.1 Compliant Software Page t.of 1
f
FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX" = 100
The lower the EnergyPerformance Index, the more efficient the home.
SPANISH LAKES, FT. PIERCE, FL,
1. New construction or eAsting
New (From Plans)
9. Wall Types
Insulation
Area
a. Concrete Block - Int Insul, Exterior
R=4.1,
1312.00 fN
2. Single family or multiple family
Single-family
b. Frame- Wood, Adjacent
R=11.0
400.00 ft'
3. Number of units, it multiple family
1
c. WA
R=
ft'
2
d. WA
-R=
ft'
4. Number of Bedrooms
10. Ceiling Types
Insulation
Area
5. Is thisaworst case?
Yes
a.. Under Attic (Vented)
R=30.0
1720.00ft'
6. Conditioned floor area (ftz)
1720
b. N/A
R=
ft'
e.
R
7. Windows" Description
Area
11.Ducfct s
R IF
a. U-Factor. Sgl, U=0.50
141.25 ft'
a.: Sup: Attic, Ret Attie, AH: Attic
6 147
SHGC: SHGC=0.25
b. U-Factor: WA
IF
SHGC:
12. Cooling systems
kBtulhr
Efficiency
c. U-Factor: WA
ft'
a. Central Unit
34.8
SEER:15.00
SHGC:
d. U-Factor. N/A
ft'
13. Heating systems
kBtu/hr
Efficiency
SHGC:
a. Electric Heat Pump
35.0
HSPF:8.50
Area Weighted. Average Overhang -Depth:
3.699 ft.
Area Weighted Average SHGC:
0.250
8. Floor Types
Insulation
Area
14. Hot water systems
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation
R=0.0
1720.00 ft'
a. Electric
EF: 0.92
b. NIA
R=
ft'
b. Conservation features
c. N/A
R=
ft2
None
..
15. Credits
Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise,a new EPL Display Card will be completed
based on installed Code compliant features. /I --
Builder Signature'.
_ Date: W
Address of New Home. `y \��5�� City/FL
'Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
""Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
621/201611:18 AM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Sottp/ur 00PT Page l of t