HomeMy WebLinkAboutPLANS`'- j _... Planning & Development Services Department
Building & Code Regulations Division
°.._ 2300 Virginia Avenue, Fort Pierce, FL 34982 - (772) 462-1553
Certification for Design Load Compliance
Project Name: MODINE _WINDOW / DOOR SCHEDULE
Project Address: 17600 PINEAPPLE LN. EXTERIOR
MARK TYPE / SIZE
Permit #: Occupancy Type: R Construction Type: V 1 9' W X T H OVERHEAD DOOR
INSTRUCTIONS FOR USE:
2 16' W X T H OVERHEAD DOOR
• This certification must be completed, signed, and sealed by the design professional of record.
3 S.H. 33 WINDOW VL
• Submit 2 copies for residential (3) copies for commercial with all permit applications involving the following: 4 36" W X 80" H S.C. DOOR W/ SIDELITES
I l P P P PP g g, 5 S.H. 25 WINDOW
o New Residences (single or multi -family) � -
o Residential Addition F LE
� 6 DBL 36" W X 80" H FRENCH DOOR
o Any accessory structure requiring a building permit
7 36" W X 80" H S.C. DOOR
o Any non-residential structure.
• Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions. INTERIOR
MARK TYPE / SIZE
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) A 36" W X 80" H S.C. SWING DOOR
1. DESIGN CODE: Florida Building Code 2010 Edition with 2010 Supplements using ASCE 7-10 B 36" W X 80" H SWING DOOR
2. Structure Designed as (check one): X Enclosed -Partially Enclosed _Open C 32" W X 80" H SWING DOOR
3. Risk Category: _1 X II_III_ IV Exposure Category: B X C D D 30" W X 80" H SWING DOOR
4. Design Wind Velocity 160 mph 124 Aso N/ALRFD End Zone Width: 5 ft E 24" W X 80" H SWING DOOR
S. Mean Roof Height: 15 ft Roof Pitch: 3 :12 Parapet: N/A It F DBL 30" W X 80" H BI-FLD DOOR
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): G DBL 24" W X 80" H BI-FLD DOOR
Zone 1: 19.3 Zone 2: 19.3 Zone 3: 19.3 Zone 4: 33.6 Zone 5: 33.6 Garage: 31.8 H 36" W X 80" H POCKET DOOR
30.7 53.5 -79.1 -36.4 44.9 -41.5 1 36" W X 80" H BI-FLD DOOR
7. Design Loads: Floor: 40 PSF Roof/Dead: 7 PSF Roof/Live: 20 Balcony: • N/A PSF „
Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PLF / CONCENTRATED 36 W X 80" H CASED OPENING
8. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? _Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County.) also certify that structural elements depicted on these plans provide adequate resistance to the design
forces specified:
ON PLAN 8/13/2014
Signature, Date, and Seal
SLCLUV Form p 02U-12 Revised 3/IS/12 (JS)
1
. L
,......
CaUIN Y
r 1 o n r. n n -
-
1
Building Permit #
Paul Welch P.E.
Print Name
Paul Welch Inc.
1984 S.W. Biltmore St. Suite #114
Company Name & Address
29945 / 5115
Cert # & Co. Cert Auth.
St. Lucie. FL
Planning & Development Services Department
Building & Regulations Division
Product Review Affidavit
Owners Name Mool"IE
Applicant:
Product
Opening Design
Pressures
Product Rated
Desi n Pressure
Manufacturer
Model Number
Product Approval
Number
Glass
Type
Mdhod of Attachment '
Windows
SEEELEVA7IAiJS
+55 ^:5T10
FCty7
5F1-2c�
ullA 01 .12
B•,S
)/4"> _Ira". MIN,�CM6eD TAPc.oUS 6.7
Mullions
FI Gla
NIA
.�-`"`
_....--•.��,�--
...�.�-�
_..
CjID1Nl9
•44°J
` 6J°�.
�ANI"§1-�ACD1�
NA r (AtsK
NOAit031\.O'1
�10.
4-1144A►AV-0TS PFR• "?,,D17L44Y. Ncit.$
EEE
EEELEVATt
+I•$0
3ElQ'WEN
5T¢ELoP09oC
f-L'd1113to,1
NIA
9$.s III%."tN ENt3�ED `7L¢ew5 To Bw.K
o.T to" 12=/•' o,[.
French Doors
+I.45
7EIA•NIFN
4LACIA100
FL4.125o9,3
ww-
N'u•
9/t6':. 'i44MIN ¢MC3cD TAPLONS to
5 �^
ara
+
�� 'Q{
oZ w -09
FLµ 5684•
51it•" 9 ISIs Mai, EMbeo LAa 54tirwS
¢ r- le" T -_- _ .. ,�..
Hurricane Protection
4/- 50
VAyTL121,1
24' w (ji b/,
FLub 11944, Z
N (Q
itI Z�'„DI G �tt5P:0 TAFCtMyS 4T
`-+ Dt',WOYJ1bL
it-55,o
7eLD-W¢N
KtgEQLA.ST
FL4i\3354,1
Now•
irtPGci
11u" KVT MA tw tM6¢D TAPcmuS T
3I 6•4, J"a6 C606ft950F 41crNikkli149ML
Roofing Material
ti 53,s
L3 T9,1
�I cc°1,%5
it �g,zs
3 -129,25
-SQ
TAtLoss
5�COAPI
FLrt1452a,
IJ/A
PER (iDOFINL:U ,a'r'r ACU METsT
N SUee r 31 9
I have reviewed the above components or cladding and I have approved their use in this strw ture. These products provide adequate resistance to the
wind loads and forces specified by current code provisions.
Name: PAUL WELCH P.E. Signature: ON PLAN
Design Prof: i PAUL WELCH P.E. Cert. No. 29945 Date:
3
JWML
SCHEDULE
LINTEL LENGTH/TYPE-"
SAFE APPLIED SAFE APPLIED COMPOSITE
NO. -
GRAVITY GRAVITY UPLIFT UPLIFT BEAM
LOAD LOAD LOAD LOAD
L4
T�"
2'' 10" 34"
6-�1-1-3
4}4C6�01
-
oc�gr'-T-
LYL
�T-�-. TT
3'' " 4; 42" LI OTLS
JY"
J>Tl
9F1�
L4
4' 0" 48" 11 r II, a
38N
3079
ovt� 4121-1T
1.4
44'-6" 54" U-LINTELS
6133
650
2f7t2t41
450
SF161B-1T
L4
5' 4" 64" U LINT LS
'&36-5
22W
; t� !t l6 IT
L-6
V-10" 70" U-LINTELS
4360�
1124
2093
713
SF161B-1T
L-4
6' 6" -/9„ T U paT.i C
3480
4W
8F16 ter
L-8
7'-6" 90" U-LINTELS
2661
1482
1634
743
8F161B-IT
L-9
9' 4" 11,1+ Too
4543
4-I33
o41oy 4B- T
L•10
11'4" 136" U-LINTELS
1366
1124
795
714
8F161B-1T
L-4
3' 6" ""- RECESSED
8974
SSCA
a zT
L-1-2
4' 6" 54" RECESSED
4292
IiM
81324 i11-44
L43
5' 10" 70" REoESSM
60M
am
W244n�r
L44
�' 6,> °-moo DE^QED
4283
53--5
eF-tr
L-15
71 61, 90" RRRGESSED
&668
2574
8F24 a
L46
9' 4" 112" PD
M
Tit
4L`Oy,p 1�D 1T
L-1-7
I14"136" rl'�`Eb-
4366
795
912164114-T
L49
12' 0" 144" U LR4TEIS
12-54
697
9�t�, �
L-19
13' 4" 1<n"r--roo ELS
447S
8F 649-1T
L-20
11'' 02 168"" U L241ELS
4002
486
gF46 lo-Ti
L-21
10'-6" 120" PRESTRESSED
2093
1124
1185
713
8F20 1B-1T
L-22
17'-4" 208" PRESTRESSED
950
450
1 404
150
SF16 1B-1T
1-23
17'-4" 208" PRESTRESSED
1326
750
520
401
SF201B•1T
1N-
HTcET� � °i=Ei i
121�1a✓2tl1Ai
a
DWELLING/GARAGE FIRE SEPARATION
THE GARAGE SHALL BE SEPARATED AS REQUIRED BY TABLE R302.6. OPENINGS IN GARAGE
WALLS SHALL COMPLY WITH SECTION R302.5. THIS PROVISION DOES NOT APPLY TO GARAGE
WALLS THAT ARE PERPENDICULAR TO THE ADJACENT DWELLING UNIT WALL.
TABLER302.6 DWF.LL1NtWrA11Ar V RF.PARATTnN
SEPARATION
MATERIAL
Not less than'/2-inch gypsum board or
From the residence and attics
equivalent applied to the
garage side
From all habitable rooms above the garage
Not less than 5/s-inch Type X gypsum board or
equivalent
Structure(s) supporting floor/ceiling assemblies
used for separation
Not less than 1/2-inch gypsum board or
required by this section
equivalent
,Garages located less than 3 feet from a dwelling
Not less than'/2-inch gypsum board or
)unit on the same
equivalent applied to the
Mot
interior side of exterior Walls that are within
L.
this area
OPENING PROTECTION.
OPENINGS FROM A PRIVATE GARAGE DIRECTLY INTO A ROOM USED FOR SLEEPING PURPOSES
SHALL NOT BE PERMITTED. OTHER OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALL BE
EQUIPPED WITH SOLID WOOD DOORS NOT LESS THAN 1%INCHES (35 MM) IN THICKNESS, SOLID
OR HONEYCOMB CORE STEEL DOORS NOT LESS THAN 1% INCHES (35 MM) THICK, OR 20-MINUTE
FIRE -RATED DOORS.
,--- I=Lt:c,rt
i M
NAME
AREA
A/C AREA
2651.9
eq
ft,
GARAGES
1783.6
aq
ft.
PORCHES
592,8
eq
ft.
TOTAL AREA
5034.3
aq
ft,
FLOOR PLAN
SCALE 3/1(o = 1'
�eALED FASTENERS OR ATTACHMENTS
ARE THE RESPONSISILI'TYOFTHE
C, N 11MI,,I CFEME
J
1
STRUCTURE AS BEEN DESIG ED
REVIEWED F9R COMPLIANCE a F
608.1.4 FOR ONE OF THE FOLLOWING.
'-ERNAL WIND PRESSURE
WINDBORNE DEBRIS PROTECTION
IMPACT RESISTANCE GLAZING
(Int.)
THFSF PLANS AND ALI_ PROPOSED WO(
ARE 6UKIEC,T EOJ",lrl,C1744FUI0NS
RE0I11REi.1 RY FIELD IMy. if(,T(AS iHAT
MAY Hl,P;E:c£SSAfIY 44 OWFR TO
COWLY WITH ALL A11KICAULE CODES.
Ign1w1 - Ili IL
ST. LUCIE COUNTY
BUILDING
REV EWED°" 'SCNNNED
FOR COM E BY
REVIEWED BY St• LUCd@Cr!'
LANS .':
DATE �7
D P RMIT
MUST BE KEPT ON JOB OR
NO INSPECTION WILL BE MADE
PAUL WELCH INC.
MECHANICAL + ELECTRICAL t CIVIL ENGINEERING
1984 SW BILTMORE ST - SUITE #1 14 c;
PORT ST. LuciE, FL 34984
PHONE EMAIL FAX
(772)795-9608 PWELCHINC@AOL.OUM (772)785-9933
PAUL WELCH, P.E., FL REG. No• 29945
OF
0
11
NOTE: WHEN LINTEL IS IN VARIOUS LOCATIONS, WORST CASE LOADING IS SHOWN
NOTE: PROVIDE "CASTCRETE" PRE -CAST CONCREE LINTEL AS NOTED ON PLANS.
0
— - iL '(n P)
--j- r-rE
-..- + 33,(v( 44, 9
?tlf'
33,4, (- 3a,4 r 33,1./ 3�.9 + 33, � I - p 4 t 33,401- 44,9
��F pew
FRONT LEVA ION
1�4`` 5cp.tg
11�21
I
U LLD
t33. -370,1 +M4 - s4,t t.33. - -
4i -3�,2
/fir- p F ?s F
BACK ELEVATION-
sl-,00
41,5 P5F +31-b( - 41.5 Fl5F
LEFTSIDE ELEVATION
9
TOE NAIL 5
2x4006CNAL 09ACE4.ESTP..A1 _
LOCAWH AS 5H M 6' 0C-
(2) IOd TYR
EA nnas
1x4 LATERAL c ZACM6 �
L0--A70H A5:40P* ON ,-LAIN
REINFORCE VERMAL INE42EF5
OF E.45LE 60 TAMS W/294
, E-a4ACE AT EA. VERT.
NAIL Y495d NAILS 6 b° O/.
+ 33, 4 ) 3it<'L W-",e
ELEVATION-
SEP 16 2014
ROOF 5HEAMN6 NAIL PER socalLe
-� 5ALV. DRIP ON IX2 P.1' NAILER ON
2X6 pOZ14 SAWN WOOL'1 FASCLA -
FASCIA BOARD ANCHORED 7o LADDER W/
Ibd NAILS a 5" O16
2x4 LADDER a 12' O/4
° CONT. 2x4 LADDER PLATE Awymw To 6E
\ 'a1-S W Ibd NAILS a 8' Q/C MAX.
\ ~ WALL SHBATNW NAIL FM 5CF's E
6ASLE &V FASTEN TO SLEEPER W/
16d NAILS 0 4" 0/6 TYPICAL
STRAP 6 a TRI155 TO O.T. W/ I!aP
L9TAIS 9TRAP a 24" O/C M/ W I0d
NAILS EA. MEMBER
\� ZX4 oWCKIN6 m 2'-O"0/c
GABLE END
CONNECTION DETAIL
i 33, 4 I -.5&,L PSF
r
FAjff�n�
PAUL WELCH INC.
P1EC1-IANIO4L a ELECTRICAL > CIVIL ENGINEERING
1 964 S.W. HILTMC]RE ST. - # I 1 4
FORT SAIN"I I_LIGIE, FL. 34969
F"ONE E-N-^AIL-� _ FAX
1772i 755'9BBB 2b'ELL'HIGW&bQL AGM 1772) 7a5 9933
PsuL F I.. - FL REG. No. 29995
StIEEi IHUio113E1i �{`
OF
,y
�p� Flr- - os DPP°�li�l�
N.Df> Neap
ALL....EGHT 511I0SPPC.IFi(a- 1
I I Z Z Z Z
{ID�D-LSep2,
1„ 1
If
2► 1_nN
c. , > 14
I
-
RR?
' r
/
V
I
}
I
3c�"x fib' F-I.
1
1 LEve` LQuplti(,
m
I I
O
Lc
_O
�
I
A.,
— Z a p
Z�-4" U _
�PIZovIpE DRIP PAWa Tug
1 AND PsI161N CITE)r yrc,
To mwTsR1o� 01�� -, i I
C vw A_NA rlu
_b
rit+V I 1 AW
3- p
45TLP —�
1
I 1
rz
I LT 1 I RYF
Y
V,
GARAGESFLOORSU"ACE
0 GARAGE FLOOR SURFACES SHALL BE OF APPROVED NONCOMBUSTH3LE
MATERIAL.
2) THE AREA OF FLOOR USED FOR PARKING OF AUTOMOBILES OR OTHER
VEHICLES SHALL BE SLOPED TO FACILITATE THE MOVEMENT OF LIQUIDS TO
A DRAIN OR TOWARD THE MAIN VEHICLE ENTRY DOORWAY.
SG 4L, E -3/ l & = I'
-P7 A --pp
Gl�eipFpFLE�Sjll�
mI �D
I°-a7 u�s�Ml
14 loar�Ls
HsmK 4TLIP
MILL Leld& }} :�uP�,
o L16o�+i@
YP B �I ao fib a.
syTp b-9� 4�51Mf��gvLl
s U21J7 PEA�IIJ��
el
FOUNDATION SCHEDULE
F-1 16" D X 16" W (2500 PSI) CONCRETE MONOLITHIC
FOOTING W/ (2) #5 BARS CONTINUOUS
F-2 16" D X 16" W (2500 PSI) CONCRETE MONOLITHIC
FOOTING W/ (3) #5 BARS CONTINUOUS
F-3 12" D X 12" W (2500 PSI) CONCRETE MONOLITHIC
FOOTING W/ (2) #5 BARS CONTINUOUS (STEP FIG)
S-1 4" THK (2500 PSI) CONCRETE SLAB W/ FIBERMESH
OR 6"/ 6" 10/10 WWM OVER VAPOR BARRIER ON
CLEAN COMPACTED CHEMICALLY TREATED FILL
C - g"wloe Gua6
IZ.t'c°eSs A r 4.4.Icwte-
McCE5S A-r C)4-{ b
�mwffljmlw
0�
N
-4° To
PLUMBING NOTES:
1) ALL WORK SHALL BE IN ACCORDANCE WITH THE FBC 2010-PLUMBING
2) DW V PIPING SHALL BE SCHEDULE 40 PVC.
3) WATER PIPING IN BUILDING SHALL BE ONE OF THE FOLLOWING: TYPE L
COPPER, CPVC, OR PEX.
4) SLEEVE ALL PIPING IN CONTACT WITH CONCRETE OR UNDERGROUND
WITHIN BLDG.
PAUL WELCH INC.
MECRAN�CAL t ELECTRICAL �' CIVIL ENGIN EERIN�
1 9B4 SW BILTMORE ST - SUITE #1 1 4
PORT ST. LUCIE, FL 34964
PHONE E-MAIL
FAX
(992)985-9SBS PWELCHINQCaAOL.COM (792)IB5-9933
PAUL WELCH, P.E., FL RE,. No- 29945
Y
4Pro
F6.1
c�
C�
r-I
e
SEP 16 2Q"
Cr
ROOF SHEATHING NAILING ZONE nts -•
(IYPICALGOUNCROOF PL1V PLAN VIEW-)
NAILS AT 6" O.C. PERIMETER AND 6" O.C. FIELD
20
NAILS AT 6"
O.C. PERIMETER AND 6"
O.C.-FIELD
NAILS AT 4"
O.C. PERR ffiTER AND 6"
O.C. FIELD
"
"A" - 8 FEET
NOTE: ROOF SHEATHING SHALL BE 19132" TUCK CDX PLYWOOD ROOF SHEATHING
FASTENED TO ROOF FRAMING WITH 8d RING -SHANK NAILS (PER FRC803.2.3.1) SPACED
PER ZONE DESIGNATIONS AS SHONW ABOVE.
STUCCO OVER WIRELATH W/ 1 IGA. 2"
KAILS W/ 3/8" 0 HEAD @ 6" O.C. OVER
3/8" METAL RIB LATH @ 6" O.C. W/ (2
LAYERS) OF 15# FELT OVER WD
FRAMING MEMBERS (TRUSS TAILS).
PROVIDE 6"X 18" SOFFIT VENTS @. 48"
O.C.
STUCCO SOFFIT DETAIL nts...
II II 1
II II i
� II II 1
1 1 I 1
1 48' _ 1 15'-01R' _ : _._.__ _. iT-111/2'
5-V PANEL PROFILE
24" Coverage
-V FASIENEP DLTAIL
METAL ROOF PANEL FASTENER: #9 -15 X 1 '/z" SCREWS WITH SEALING WASHER IN THE CROWN
OF THE RIB OF THE PANEL, '/4" MININ[UM PENETRATION THROUGH THE PLYWOOD. ALL
FASTENERS TO BE CORROSION RESISTANT. FASTENERS SHALL BE INSTALLED AT 12" O.C.
PERPENDICULAR TO ROOF SLOPE FOR ALL ZONES AND 8" PARALLEL TO ROOF SLOPE AT ALL
CORNER ZONES (ZONE 3), AND AT 16" PARALLEL TO ROOF SLOPE AT ALL FIELD AND PERIMETER
ROOF ZONES (ZONE I AND 2).
ROOFING ATTACHMENT nts...
PER FL# 14520.1 JA TAYLOR ROOFING 5 V CRIMP
PRODUCT DESIGN PRESSURE (PSF): ZONE 1&2: -69.25 / ZONE 3:-129.25
METAL ROOF PANELS SHALL BE SECURED TO THE SUPPORTS IN ACCORDANCE WITH THE
APPROVED MANUFACTURER'S FASTENERS. METAL PANELS SHALL BE ATTACHED PER
MANUFACTURER'S SPECIFICATIONS AND DETAIL THIS SHEET.
UNDERLAYMENT SHALL BE INSTALLED AS PER MANUFACTURER'S INSTALLATION GUIDELINES
UNDERLAYMENT SHALL BE APPROVED 304 ROOFING FELT.
UNDERLAYMENT APPLICATION.
UNDERLAYMENT SHALL BE ONE LAYER APPLIED IN THE FOLLOWING MANNER, UNDERLAYMENT
SHALL BE APPLIED PARALLEL TO AND STARTING FROM THE EAVE AND LAPPED 2 INCHES (51
MM), FASTENED SUFFICIENTLY TO HOLD IN PLACE. DISTORTIONS IN THE UNDERLAYMENT
SHALL NOT INTERFERE WITH ROOF PANNEL INSTALLATION.
FLASHING SHALL BE INSTALLED IN SUCH A MANNER SO AS TO PREVENT MOISTURE ENTERING
THE WALL AND ROOF THROUGH JOINTS IN COPINGS, THROUGH MOISTURE -PERMEABLE
MATERIALS AND AT INTERSECTIONS WITH PARAPET WALLS AND OTHER PENETRATIONS
THROUGH THE ROOF PLANE. ALL FLASHING SHALL BE IN ACCORDANCE: WITH FLORIDA
BUILDING CODE
FLASHING SHALL BE INSTALLED AT WALL AND ROOF INTERSECTIONS, AT GUTTERS, WHEREVER
THERE IS A CHANGE IN ROOF SLOPE OR DIRECTION AND AROUND ROOF OPENINGS. WHERE
FLASHING IS OF METAL, THE METAL SHALL BE CORROSION RESISTANT WITH A THICKNESS NOT
LESS THAN PROVIDED IN FBC TABLE 1503.2. THIS REQUIREMENT DOES NOT APPLY TO HIP AND
RIDGE JUNCTIONS.
ALL ROOFING INSTALLATIONS SHALL BE IN ACCORDNNCE WITH FBC 2010.
US "GRB" 2"D BEARING
SIMPSON NITS 16 W/ (14) - 10d X 1 V2"
IUBLE 2 X 4 WOOD TOP PLATE
VIPSON SP4 EACH STUD TOP AND BOTTOM
ATES W/ (6) -10d EACH
FULL LENGTH 2 X 4 WOOD STUDS UNDER
ARING POINT
2 X 4 WOOD BOTTOM PLATE WITH
- 5/8" X 6" WEDGE ANCHOR OR J-BOLT
TH 2" X 2" X 1/8" WASHER WITH IN 6" OF
RT STUD
DETAIL AT TRUSS GR 2ND BEA ING -I-
TRUSS CONNECTOR
SCHEDULE
TRUSS IDnBEARING
TRUSS ACTUAL
CONNECTOR
ID
CONNECTOR
UPLIFT DESIGN
FASTENERS
NOTESUPLIFT
D4, D7, & D9
GRA
GRB
GRC
GRC
GRD
1ST
2ND
1ST
1486(1)
1425
1340
1232
2562
4071
1 000
HETA 20
(1) HETA 20
(i) HETA 20
(2) MTS 16
(1) MGT
(1) FGTR
(1) HETA 20
1810
1810
1810
2000
3965
5000
1810
(9)-10d X 11/2"'
(8)-16d
(9)-30d X 11/Z'"GRB
(14)-10d X 11/2" SEE DETAIL
(22) - 10d & (1) - 5/8" A.B. * Q
(18)-SDS 1/4" X 3" & (2) 1/2" X 5" TITEN HD
(9)-10d X 1 1/2"'
VALLEYS
CONT.
100 # PLF
( ) MTS 16
1000
(14)-10d X 1 1/2"
1
T 1 STRAP AT
EACH END AND AT 24" O.C.
ALL OTHERS
LESS THAN 1000#
TRUSS COMPANY
EACH
EACH
CHAMBERS TRUSS
< 1000#
< 1000#
LAYOUT DATE
(1) HETA 20
(1) MTS 16
4 28 2014
1810
1000
CUT -SHEET DATE
(9)-10d X 1 1/2"
(14)-10d X 1 1/2"
4 29 2014
AT CBS BEARING
AT FRAME BEARING
* NOTE: USE SIMPSON EPDXY STRONG TIE SYSTEM WITH 12" MIN. EMBEDMENT.
NOTE: ALL STRAPPING TO BE SIMPSON STRONG -TIE AS SPECIFIED.
1 VALLEY TRUSSES MAY BE ATTACHED WITH SIMPSON VTCR W/ (4)- #9 SD X 2 1/2" TO SUPPORTING TRUSS AND (3)- #9 SD X 1 1/2"
TO VALLEY TRUSS IN LIEU OF MTS16 AS STATED. VTCR SHALL BE INSTALLED AT EACH END AND 24" O.C. MAX.
2 SIMPSON FGTR WITH (18)-SDS 1/4" X 3" & (2) 1/2" X 5"TITEN HD MAY BE USED IN LIEU OF MGT AS SPECIFIED ABOVE.
TRUSS NOTES: --
1) ALL ROOF TRUSSES TO BE DESIGNED BY TRUSS COMPANY'S ENGINEER.
2) CONTRACTOR TO PROVIDE PAUL WELCH INC., AND BUILDING DEPARTMENT WITH ENGINEERED
TRUSS DRAWINGS BEFORE INSTALLING TRUSSES.
3) CONTRACTOR TO VERIFY ALL EXISTING ROOF CONDITIONS, AND DIMENSIONS BEFORE ORDERING,
AND INSTALLING TRUSSES.
4) TRUSS TO TRUSS CONNECTIONS TO BE PROVIDED BY TRUSS COMPANY. -
5) SEE TRUSS CONNECTOR SOH. FOR TRUSS TO WALL CONNECTIONS.
F E Cnw�v
Lu
PAUL WELCH INC.
MECHANICAL , ELECTRICAL . CIVIL ENGINEERING
1 9a4 SW BILTM.ORE ST - SUITE #1 14
PORT ST. Lucm, FL 34984
PHONE E-MAIL FAX
(772)785.9BB6 PWELCHINCQADL.COM (7721765-9933
SEP LO� PAUL WELCH, P.E., FL RE13. No. 29945
04
W
(4rd 00
�I
SHEET PIUi�IdNi /If
4//L
1262
,4t
5 V CRIMP METAL ROOF OVER 30#
FELT OVER 19/32" CDX PLYWOOD
_
ROOF SHEATHING
NOTES:
SIMPSON LSTA 12 W/ (10)- 10d NAILS
/
FROM JOIST TO JOIST OVER RIDGE
1)
THE CONTRACTOR SUBCONTRACTOR, SUPPLIER, ECT. SHALL VERIFY A6
DIMENSIONS, CONDITIONS AT JOB SITE, PLANS, SPECIFICATIONS, ECT.
2 X 8 WOOD RIDGE JOIST
2)
STRUCTURAL FEATURES NOT DETAILED ON THESE PLANS WILL BE
3)
ADDRESSED BY THE ENGINEER AS CONSTRUCTION PROGRESSES.
ALL WRITTEN DIMENSIONS ON THESE DRAWINGS TAKE PRECEDENCE OVIVR
(3) —12 d NAILS EACH SIDE TOE NAM
SCALED DIMENSIONS.
4)
ALL CONSTRUCTION MUST COMPLY WITH THE FBC 2010, AND THE FBC2
2010
X 4 WOOD COLLAR TIE EACH JOIST
I
RESIDENTIAL, 2010 PLUMBING CODE, 2010 MECHANICAL CODE AND THE NVC
W/ (4) —16 d NAILS EACH END
(NFPA 70) 2008 EDITION.
5)
RESIDENCE LOCATED IN NEGLIGIBLE WEATHERING AREA, AND IN VERY HEAVY
FASCIA / SOOFIT PER TYPICAL
TERMITE INFESTATION AREA PER FRC 301.
SECTION
CUT DOWN JOIST TAIL TO 4" —•—�
STRUCTURAL NOTES
-
1)
DESIGN LOADS IN ACCORDANCE WITH ASCE7-10.
2)
SOIL BEARING CAPACITY: 2500 PSF (MIN.).
3) ALL STRUCTURAL CONCRETE IN BEAMS, LINTELS, VERTICLE CELLS, AND
COLUMNS SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI
COMPRESSIVE STRENGTH AT 28 DAYS. SHVIPSON SP4 EACH STUD TOP AND _ I
4) SLAB / FOOTINGS TO BE CONCRETE WITH A MINIMUM 2500 PSI COMPRESSIVE BOTTOM PLATES W. (6) -10d NAILS
STRENGTH AT 28 DAYS. SEE PLAN FOR SIZES & STEEL REQUIREMENTS
5) MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS: SIMPSON LSTA 12 W/ (10)- 10d OR �F
FOOTINGS: 3" BEAMS: 1 h" SUSPENDED SLABS: 114" SIMPSON MTS16 W/ (14) -10d FROM { -- — —
6) LAP ALL REINFORCING STEEL A MINIMUM OF 48 BAR DIAMETERS EXCEPT AS BOTTOM PLATE TO TRUSS AT 24" O.C.
NOTED GRADE 60 STEEL MINIMUM IN BEAMS AND COLUMNS. FRONT
7) ALL LUMBER IN CONTACT WITH CONCRETE OR MASONRY SHALL BE
PRESSURE TREATED.
8) SPLITING OR CRACKING OF STRUCTURAL COMPONENTS DUE TO PROVED 2 X 4 CROSS BRACE AT EACH
INSTALATION OF HARDWARE IS NOT PERMITED. SIDE OF RIDGE W/ (3) —12 d NAILS,
9) UNLESS OTHERWISE NOTED, THE INSTALLATION OF SPECIFIED HARDWARE EACH END
SHALL CONFORM TO THE MANUFACTURES INSTRUCTIONS AND STANDARD
PRACTICIES.
10) LINTELS SHALL HAVE A MINIMUM 4" BEARING EXCEPT RECESSED LINTELS
SHALL HAVE 8" BEARING.--
11) PROVIDE # 5 CORNER BARS W/ 30" MIN. LAP SPLICE FOR BOND BEAM.
/� 7
12) STUCCO SOFFIT AND EXTERIOR CEILING NOTE: SOFFIT AND EXTERIOR
CEILING TO BE STUCCO OVER WI;ELATH W/ 11GA. 2" NAILS W/ 3/8" 0 HEAD @
\\
6" O.C. OVER 3/8" METAL RIB LATH @ 6" O.C. W/ (2 LAYERSOF 15# FELT OVER
EACH FRAMING MEMBER).
13) EXTERIOR FRAME WALLS AND BEAMS TO BE STUCCO OVER WHRELATH WITH
11 GA. 2" LONG NAILS WITH 3/8" 0 HEAD @ 6" O.C. OVER (2) LAYERS OF (15#
SIMPSON SP4 EACH STUD TOP AND
FELT OR TYVAK BUILDING WRAP) OVER FRAMING.
BOTTOM PLATES W. (6) -IOd NAILS
14) PROVIDE HARDIE PLANK SIDING AT EXTERIOR WALLS AT FRONT ELEVATION
SEE HARDIPLANK NOTES FOR ATTACHMENT SPECIFICATIONS.
SIMPSON LSTA 12 W/ (10)- IOd OR
HARDIPLANK NOTES:
SIMPSON MTS16 W/ (14) -10d FROM
HARDIPLANK SIDING AT GABLE END TRUSS, CHIMNEY AND COUPOLA TO BE
BOTTOM PLATE TO TRUSS AT 24" O.C.
ATTACHED OVER TYVAK BUILDING WRAP OR 15# FELT OVER NEW PLYWOOD.
HARDIPLANK TO BE APPLIED HORIZONTALLY WITH 1 '/A" LAPS AT TOP OF
PLANK. HARDH'LANK TO BE ATTACHED WITH 8D X 2 Vz" LONG GALVANIZED
BOX NAILS PLACED IN THE OVER -LAPPED AREA AT 8" ON CENTER
VERTICALLY AND 16" ON CENTER HORIZONTALLY INTO STUDS THROUGH
5/8"PLYWOOD SHEATHING. 5/8" PLYWOOD SHEATHING TO BE NAILED TO
STUDS WITH IOD NAILS @ 4" O.C. PERIMETER AND FIELD
HARDIPLANK SIDING AT CBS TO BE ATTACHED OVER TYVAK BUILDING WRAP
OR 15# FELT OVER 2"X2" FURRING @ 16"O.C. HARDIPLANK TO BE APPLIED
HORIZONTALLY WITH 1 Va" LAPS AT TOP OF PLANK HARDIPLANK TO BE
11
J ;
_ I
" " 1 TMSPON MTS 12 W/ (14) -10d NAILS
iACH
JOIST
DBE 2 X 4 CONTINUOUS WOOD TOP
PLATE
HARDIEPLANK SIDING PER NOTES
2 X 4 WOOD STUDS AT 16" O.C.
FIREPLACE OPENING
Front opening width: 42"
2X4 WOOD BOTTOM PLATE W//" X 3
Front opening height: 24-
VP LAG SCREW TO TRUSS AT 24" O.C.
TECHNICAL INFORMATION
,� \
Flue Series (StdJ: SK8 Doude Wall
METAL FLASHING AT ALL ROOF /
Flue Size: 8' Inner; 11 " Otter
WALL INTERSECTIONS
Clearance to Chimney Pipe: 1-1/2"
Firestop Framing: 14-112' x 14-112"
_ EXTEND CORNER STUDS DOWN TO
Minimum Hue Height 90 6"
Maximum Flue Height 90'
BOTTOM CHORD OF TRUSS W/ (2) -16d
Minimum Height with 2 Elbows: 14' 6"
I j NAILS AND SIMPSON MIS 16 W/ (14)
Minimum Height with 4 Elbows: 21'
10d NAILS
Clearance to Fireplace; 112" to sides and back
Minimum Hearth Size: 16" x 48
UUULC Design Cerdfied
__--- "--
FIELD INSTALLED ACCESSORIES
-
Bi-fold Glass DoorsBrushed Brass, Black, Polished Brass, Pewter
NOTE: BALLON FRAME GABLE END _
Fan Kit: FK12 (Circulating Fireplaces only)
WALL (DOUBLE FRAME WINDOW
OursideAir KR: AK -MST•
OPENING
Terminations (Std.): SKB Series RLTSK8, RLTSK8L, PLTSK8, SLTSK8
'Nate: Forindoorapoliofimsml.. NotrecommendedfwaMminsroot=.
0=5 )
I M
EXTEND CORNER STUDS DOWN TO
BOTTOM CHORD OF TRUSS W/ (2) -16d
NAILS AND SIMPSON MTS 16 W/ (14)
10d NAILS
SIDE
ATTACHED WITH 8D X 2 % LONG GALVANIZED BOX NAILS PLACED IN THE -
OVER -LAPPED AREA AT 8" ON CENTER VERTICALLY AND 16" ON CENTER TYPICAL COUPOLA DETAIL Dts...
HORIZONTALLY INTO FURRING. FURRING TO BE ATTACHED TO CBS WALL W/
V4" TAPCONS X 1 %" EMBEDMENT AT 16" O.C. VERT.
ADDITIONAL NOTES
1) ALL INTERIOR GYPSUM BOARD TO BE MIN. '/2" THICK WITH (13 GAGE, 1 3/8"
LONG, 19/64" HEAD; 0.098" DIAMETER, 1'/4" LONG, ANNULAR -RINGED; 5D
COOLER NAIL, 0.086" DIAMETER, 1518" LONG, 15/64" HEAD; OR GYPSUM BOARD
NAIL, 0.086" DIAMETER, 1 5/8" LONG, 9/32" HEAD) SPACED AT 7" O.C. FOR NAILS
AND 12" O.C. FOR SCREWS. (PER FRC 702.3.5)
2) WALLS AT SHOWER TO BE TILE. PROVIDE CEMENT, FIBER -CEMENT OR GLASS
MAT GYPSUM BACKERS IN COMPLIANCE WITH ASTM C 1288, C 1325, C 1178, OR
C 1278 AND INSTALLED IN ACCORDANCE WITH MANUFACTURERS'
RECOMMENDATIONS AS BACKERS FOR WALL TILE IN TUB AND SHOWER
AREAS AND WALL PANELS IN SHOWER AREAS. (PER FRC 702.4.1 & FRC 702.4.2).
3) WALL AND CEILING FINISHES SHALL HAVE A SMOKE -DEVELOPED INDEX OF
NOT GREATER THAN 450.
4) WALL AND CEILING FINISHES SHALL HAVE A FLAME -SPREAD
CLASSIFICATION OF NOT GREATER THAN 200.
5) ALL EXPOSED INSULATION MATERIALS INSTALLED ON ATTIC FLOORS SHALL i
HAVE A CRITICAL RADIANT FLUX NOT LESS THAN 0.12 WATT PER SQUARE
CENTIMETER EXPOSED FOAM PLASTIC INSULATION MATERIALS EXPOSED TO ef
THE UNDERSIDE OF THE ROOF DECK OR ON THE ATTIC WALLS SHALL \
COMPLY WITH SECTION .
6)/ \
PER FRC 702.2.1 ALL GYPSUMUM BOARD MATERIALS AND ACCESSORIES SHALL
CONFORM TO ASTM C 36, C 79, C 475, C 514, C 630, C 931, C 960, C 1002, C 1047, C
1177, C 1178, C 1278, C 1395, C 1396 OR C 1658 AND SHALL BE INSTALLED IN
ACCORDANCE WITH THE PROVISIONS OF FRC, AND ADHESIVES FOR THE
INSTALLATION OF GYPSUM BOARD SHALL CONFORM TO ASTM C 557
7) INSULATION MATERIALS, INCLUDING FACINGS, SUCH AS VAPOR RETARDERS PROVIDE R-11 INSULATION
OR VAPOR PERMEABLE MEMBRANES INSTALLED WITHIN FLOOR -CEILING AT GARAGE / RESIDENCE
ASSEMBLIES, ROOF -CEILING ASSEMBLIES, WALL ASSEMBLIES, CRAWL
SPACES AND ATTICS SHALL HAVE A FLAME SPREAD INDEX NOT TO EXCEED 25 SEPERATING WALLS \L
WITH AN ACCOMPANYING SMOKE -DEVELOPED INDEX NOT TO EXCEED 450
WHEN TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
SAME CONNECTIONS AS PER _
TYPICAL INTERIOR BEARING
WALL DETAIL \
SPREAD FOOTING (2500 PSI) SIZE
AND REINFORCING AS PER
FOUNDATION PLAN
\ / SIMSPON NITS 12 W/ (14) -10d NAILS
Y EACH JOIST
DBL 2 X 4 CONTINUOUS WOOD TOP
PLATE
— — HARDIEPLANK SIDB11G PER NOTES
2 X 4 WOOD STUDS AT 16" O.C.
— 2X4 WOOD BOTTOM PLATE W/'/4" X 3
V2" LAG SCREW TO TRUSS AT 24" O.C.
METAL FLASHING AT ALL ROOF /
1 �� WALL INTERSECTIONS
�I
>v �
PRE- ENGINEERED WOOD TRUSS
SYSTEM 24" O.C. MAXIMUM
SPACING
Vz" DRYWALL CRUANG
TRUSS TO WALL CONNECTION PER
TRUSS STRAPPING SCHEDULE
DBL 2 X 4 CONTINUOUS TOP PLATE
2X4 WOOD STUDS AT 16" O.C.
-- V2" DRYWALL WALLS
SIMPSON SP-4 WITH (6). 10d NAILS
EACH STUD TOP AND BOTTOM
PLATE (16" O.C.)
P.T. 2X4 WOOD BOTTOM PLATE
WITH 5/8" X 5'/z" ANCHOR BOLTS
WITH 2" X 2" X I/8" WASHERS AT 24"
O.C.
SPREAD FOOTING (2500 PSI) SIZE
AND REINFORCING AS PER
FOUNDATION PLAN
I ".Tmml I
Rosen I
amine - WOW
a We'
zeu• ruteu• ;}
m) I
W �,- W Remscetl
(saemn) ® bi61°ml Nalhp
® Renee
F Ro"an r•°"Ire wime ar.l
(1161mm)
dWvA (e c ul us
LOEB
omonml
INN F. ,65s•.I \ oamm)
Isetmml
.` 11®g60lmenslans
;ULATION
4 CONTINUOUS WOOD TOP
PDIB,AX
METAL CHASE TERMINATION
HARDIRPLANK SIDING PER NOTES
I
GALVANISED METAL TOP CAP.
2 X 4 W(wxD STUDS AT 16" O.C.
r
SM2SOARCWB LETIN BRACE EACH
\
/
—SIDE W/(1)-8D EACH STUD
SDI4PSON SP4 EACH STUD TOP AND
\
BOTTOM PLATES W. (6) -10d NAILS
2X4 WOOD BOTTOM PLATE W/ Y." X
Ya" LAG SCREW TO TRUSS AT 24" O.C.,
ROOF CRICKET
METAL FLUE
SIlVHPSON LSTA 12 W/ (10)- lOd OR
SD4PSON MTS16 W/(14)-10d FROM
\�
BOTTOM PLATE TO TRUSS AT 24" 0,4.
METAL FLASHING AT ALL ROOF /
WALL INTERSECTIONS
EXTEND CORNER STUDS DOWN TO
BOTTOM CHORD OF TRUSS W/ (2) 4
NAILS AND SI IPSON MTS 16 W/ (14)
iIOd
NAILS
TYPICAL CHIMNEY DETAIL 21s...
x P.T. BUCK
ALTERNATf BUCK 2"X6" OR 2"X8"
P.T W/ 3/16" TC'S W/ 1 X" MIN.
EMBD. @ 4"/12" O.C. W/ #10
SCREWS PER P/A
y PROVIDE 1 DL" CASEHARD NAILS @ J'
4" FROM ENDS AND 8" O.C. W/ TC'S
PER PRODUCTAPPROVAL
NOTE:USE VX6" P.T. BUCK
@ SGD'S
P E OR 2'J"x3 5/B" NOTE: TC' TO BE INSTALLED THRU BUCK INTO MASONRY WITH
IPLATE
MINIMUM 1 3/8" EMBEDMENT PER PRODUCT APPROVAL
UNNERPER FBC 1715.5.4.3 BUCKS MUST COVER ENTIRE DEPTH
OF JAMB.
DOD FRAMING @ 16" O.C. _
(35/8"METAL STUDS DOOR BUCK DETAIL N.T.S.
/ALL BOTH SIDES
ITT. PLATE OR I %-X3 5/8"
UNNER W/TAPCONS OR
.5 @ TIT O.C. (10d NAILS
DD FLOOR)
FLOOR
TYPICAL INTERIOR NON-B8G SEE TYPICAL WALL SECTION FOR
ADDITIONAL INFORMATION
WALL DETAIL N.T.S.
PRE- ENGINEERED WOOD TRUSSES
@ 24" O.C. (MAX. SPACING)
/ ,SIMPSON" STRAP PER TRUSS
CONNECTOR SCH,
STUCCO CLG PER STRUCTURAL
NOTE# 12
(I ROW)
8"X8" CONTINUOUS CONCRETE
BEAM BLOCK W/ (1) - #5 BAR IN _
(3000 PSI) CONC. FILLED EACH CELL
8" PRECAS LINTEL W/ (1)-#5 BAR
IN (3000 PSI) CONCRETE FILLED CELL —
(SEE LINTEL SCH. FOR
MORE INFORMATION)
,
p a r
lI �r i rl,
l o so.
LtL87{Us:L;:,
TYPICAL INTERIOR BEARING WALL W/ STEP Fits... TYPICAL INTERIOR BEARING WALL DETAIL MS...
I
Ill
VENTED SOFFIT PER SOFFIT
DETAIL
#5 REHABS W/ 90 DEGREE HOOK
S'x 16" CONCRETE BLOCK
_._ COLUMN WITH (2) - #5 BARS VERT.
IN (3000 PSI) CONCRETE FILLED
CELLS
— 5/8" STUCCO FINISH
#5 REBARS W/ 30" MIN. LAP SPLICE
(2500 PSI) CONC. FOUNDATION
— SEE PLAN FOR SIZES AND
SPECIFICATIONS
FINISHED GRADE
TYPICAL BLOCK COLUMN DETAIL nts...
ALTERNATE BUCK 2"X6" OR 2"Xe"
P.T. W/ 3/16" TC'S W/ 1 W MIN.
EMBD. @ 4"/12"-O.C. W/#10
SCREWS PER P/A
I P.T. WINDOW BUCK
PROVIDE 1 Y." CASEHARD NAILS @,
4" FROM ENDS AND 8" O.C. W/ TCS
PER PRODUCE APPROVAL
STUCCO FINISH RETURNED TO
WINDOW FRAMEON EXTERIOR
....Rol wn,.. nurs..nu
NOTE; TC' TO BE INSTALLED THRU BUCK INTO MASONRY WITH
MINIMUM 1 3/8" EMBEDMENT PER PRODUCT APPROVAL
PER FBC 1715.5.4.3 BUCKS MUST COVER ENTIRE DEPTH
OF JAMB.
WINDOW BUCK DETAIL�.TS.
e
c�
2" X 8" P.T. WD BUC9
_
W/ 3/16" X 2 Va" TAPCONS @ 12" O.C.
o
e
2" X 8" PIT WD BUCK (TYP) 3
�i
6'
• ,
BUCK W/ %" X S V2" REDHEADS. '
W/ MIN, 2" 0 X 1/8" WASHERS -
GARAGE DOOR BUCK DETAIL. °U••• 5V CRIMP METAL ROOFING OVER 30#
FELT ON 19/32" CDX
PLYWOOD ROOF SHEATHING
/ NAILED PER DETAIL
PRE- ENGINEERED WOOD TRUSSES
@ 24" O.C. (MAX. SPACING)
_ "SIMPSON's STRAP PER TRUSS
— -- CONNECTOR SCH.
METAL FLASHING (DRIP EDGE)
1 X 2 P,T. DRIP EDGE OVER I X 6
P.T. WOOD FASCIA OVER 2X4
R-30 INSULATION
WOOD SUB FASCIA
1
I:
V2" DRYWALL (WALLS AND CLG) '_j
----
VENTED SOFFIT PER SOFFIT
DETAIL
(I ROWS)
8"X8" CONTINUOUS CONCRETE
BEAM BLOCKW/ (1) - #5 BAR IN
#5 REBAR W/ 90 DEGREE HOOK
(3000 PSI) CONC. FILLED EACH CELL
8"X8"X16" CONCRETE BLOCK
(MASONRY)
8" PRECAS LINTEL W/ (1)-#5 BAR
#5 VERT. REBAR IN (3000 PSI)
IN (3000 PSI) CONCRETE FILLED CELL
CONCRETE FILLED CELL
AT ALL DOOR AND WINDOW
(SEE PLAN FOR LOCATIONS)
OPENINGS (SEE LINTEL SCH. FOR
MORE INFORMATION)
5/8" STUCCO FINISH OR HARDIE
_
_
PLANK PER STRUCTURAL NOTES
%11 INSULATION BRD --
—
#5 REBAR W/ 30" MIN. LAP SPLICE
'/2" DRYWALL ON P.T.
1X2 FHRRING @ 16" OR 24" O.C.
i
(2500 PSI) CONC. FOUNDATION
SEE PLAN FOR SIZES AND
Imo.lE`LItln
SPECIFICATIONS
FINISHED GRADE
TYPICAL BLOCK (CMU) WALL DETAIL nts
i
SEP 16 2014
PAUL WELCH INC.
MECHANICAL - ELECTRICAL • CIVIL ENGINEERING
1 984 SW E31LTMORe ST - SUITE #1 14
PORT ST. LuclE, FL 34984
PHONE E-MAIL FAX
(7721785-9989 PWELCHINCL%GAOL.COM (772)766.9933
PAUL WELCH, P.E., FL REM. No. 29945
SHEET NUMBER
9 A
OF
3 # 3/0 THIN IN 2" C
ELECT. SERVICE
200
2
MBR
3 # 3/0, #4, 2" C
#4 CU GRND TIED
TO BLDG STEEL, CWP
AND DRIVEN GRND ROD
"EP"
120 / 240V
I�
200A
MLO
T NOTE: USE ALL COPPER WIRE.
ELECTRICAL RISER / DIST. nts...
OPTION "A"
ELECTRICAL LOAD CALC'S
PER NEC
2658 S.F. @ 3 VA
TWO 20A APPLIANCE CKTS
LAUNDRY
DRYER
RANGE
WH
DW
WP TUB (OPTION)
REFRIG
IRR. PUMP (OPTION)
MISC
TOTAL
FIRST 10 KW @ 100%
REMAINDER @ 40%
TOTAL
AIC HEAT Cad 100°h
TOTAL
3#3/0THWIN2"C
UNDER GROUND ELECT. SERVICE ,
M ' 200 120 / 240V
2 1'�
MBR 200A
MLO
3 # 3/0, #4, 2" C
#4 CU GRND TIED
TO BLDG STEEL, CWP
AND DRIVEN GRND ROD
�-IV
NOTE: USE ALL COPPER WIRE.
ELECTRICAL RISER / DIST, nts...
OPTION "B"
45749.6
240 = 191 AMPS
USE 200 AMP SERVICE
7974 VA
3000
1500
5000
12000
4600
1200
1200
1200
1800
10000
49374 VA
10000
15749.6
25749.6
20000
45749.6 VA
ELECTRICAL NOTES
1) SMOKE DETECTORS TO BE 110V W/ BATTERY BACK UP - ARC FA VLT CIRCUIT
2) SMOKE DETECTORS TO BE INTERCONNECTED SO THAT ONE SMOKE DETECTOR
ACTIVATES ALL SMOKE DETECTORS IN THE RESIDENCE
3) PROVIDE BRANCH CIRCUIT ARC -FAULT PROTECTION FOR ALL CIRCUITS SERVING:
FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS,
BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR
ROOMS PER FBC AND NEC REQUIREMENTS.
4) PROVIDE GROUND -FAULT CIRCUIT INTERRUPTER PROTECTION FOR ALL 125-VOLT,
SINGLE-PHASE 15 AND 20 AMP CIRCUITS SREVING: BATHROOMS, GARAGES,
KITCHENS, ACCESORY BUILDINGS, OUTDOORS, OR WITHIN 72" OF EDGE OF ANY SINK
5) CARBON MENOXIDE DETECTORS TO BE INSTALLED WITHIN 10' OF ALL BEDROOMS.
6) EXHAUST FANS TO BE VENTED THRU ROOF OR SOFFIT.
7) PROVIDE TAMPER RESISTANT RECPTICLES PER NEC REQUIREMENTS.
EXHAUST FANS SHALL MEET THE FOLLOWING CRITERIA:
VENTILATION RATE.
VKVI LATIONSYSTEMS SHALL BE DESIGNED TO HAVE THE CAPACITY TO EXHAUST THE
MIND" AIR FLOW RATE DETERMINED IN ACCORDANCE WITH TABLE BEI.O W.
MINIMUM REQUIRED EXHAUST RATES FOR ONE- AND TWO-FAMILY
DWELLINGS
AREA TO BE VENTILATED
VENTILATION RATES
Kitchens
100 cfin intermittent or
25 din continuous
Mechanical exhaust capacity o
Bathrooms —Toilet Rooms
50 cfin intermittent or 20 cfin
continuous
For SI: I cubic foot per minute = 0.4719 L/s.
NOTE: SEE ELECTRICAL PLAN FOR EXHAUST FAN LOCATIONS.
9
P15couwt41)
1 zriv
`NP)
3CARGARAGE—_-------- --_
Y
I %
/--------------------
I I
--------------------• %
I� 5n
v �C)
N OTC if
--------------------
-�
COVERED PORCH
---------------- \ \ C
Q
Wp 1� \
�� \ 'r 1 WpF�\Y'
Wp -
h
..
- /
CxREAT ROOM
PL. LT
YJIdi�ZOV Scr ,/�
GPI 4.
westelde / /
site Ilghting
2 CAR GARAGE
�71SLbN KPLT �� \ ,,b
Gas l'Zw c_--,�--- 0
C
N
m�- OFFIC E LAUNDRY0 KITCHEN
b
d 22
C
open
shelveE
i_ q V
MASTERBEDROOM
3
I � \
v
= Q11�
b fQ char ,
il II y '
3-0
P4: LT
�I I
DRESSING ROOM
I� AIL
zo j //
T
/• V('
eouthaide
ske Ilghting - h3G�T "
COVERED PORCH
— --------------------
----------------
ELECTRIC PLAN
SCALE 3/16= 11
A CARBON MONOXIDE ALARM SHALL
BE INSTALLED IN ACCORDANCE
WITH FA.C. RULE 9B-3.0472 WITHIN
TEN FEET OF EACH ROOM USED FOR
SLEEPING PURPOSES.
F a I
PROVIDED ELECTRIC SMOKE
DETECTORS WITH BATTERY
BACK" - UP IN ALL SLEEPING
- AREAS AND STAIR LANDING
WIRED SO THAT THE ACTIVATION
OF ANY DETECTOR WILL ACTIVATE ALL.
T
in
VarP C
p�scf
�A�
J 1 f31 SCB'K NiPc'C--j
ELECTRICAL
COUNT
SYMBOL
ceiling fan
1
ceiling fan spotlights I
8
ceiling fan spotlights 2
3
ceiling lamp small
4
cei I in I i it vent square
a 5 Tat,\
3
Ele)6
exterior light 1
3
Q
exterior light 4
2
U
ceiling globe 1153ht
8
O
chandelier
I
double spotlight
4
Qp
fluorescent fixture
-I
0
pot light
22
0
vanity bar light
1
wall mount 1
3
�
cable tv outlet
9
B
outlet
outlet 220v
2
outlet gf1
34
smoke detector
a
switch
40
$
switch 3 way
12
$3
SEP 16 2014
' F y
yt i" i a •:�
Y � '
PAUL WELCH INC.
MECHANICAL x ELECTRICAL '1 CIVIL ENGI.CERING
1964 SW BILTMORE ST - SUITE #1 14
PORT ST. Lucm:, FL 34984
PHONE E-MAIL FAX
17721785-9888 PWELCHINC@ACL.COM (772)785-9933
PAUL WELCH, P.E., FL Rea. NO. 29945
THE WEST 300,00 FEET OF THE SOUTH 750 OF
THE ZOUTHWEST 1/4 OF THE NORTHEAST 1/4
OF SECTION 14, TOWNSHIP 35 SOUTH, RANGE
38 EAST, LESS THE SOUTH 124.5 FEET, IN ST.
LUCIE COUNTY, FLORIDA
SURVEY REPORT
1.) NO SEARCH OF THE PUBLIC RECORDS HAS BEEN MADE BY THIS OFFICE.
4.) DESCRIPTION FURNISHED BY CLIENT.
5.) PARCEL SUBJECT TO ALL EASEMENTS, RESERVATIONS, RESTRICTIONS, AND RIGHTS OF WAY
6.) ALL LOT DIMENSIONS ARE PLAT AND MEASURED, UNLESS OTHERWISE NOTED
7.) PROPOSED SITE PLAN SUBJECT TO APPROVAL BY GOVERNING AGENCIES.
8.) PARCEL CONTAINS: 225,006 SQUARE FEET OR 5.2 ACRES MORE OR LESS.
9.) STREET ADDRESS: PINEAPPLE LANE
11.) ELEVATIONS SHOWN HEREON ARE BASED ON NATIONAL GEODETIC VERTICAL DATUM OF 1929 (N.G.V.D. 29),
12.) THIS IS NOT A BOUNDARY SURVEY, BOUNDARY INFORMATION SHOWN HEREON PROVIDED BY CLIENT
AND WAS TAKEN FROM A SURVEY PREPARED BY VELCON GROUP INC.
07- 4 DRAWING NO 6 , DATED 5-18-07.
13.) BEARINGS SHOWN HEREON ARE BASED ON AN ASSUMED BEARING OF N00'21'18" W ALONG THE
WEST LINE OF THE SW1/4 OF NE1/4 OF SECTION 14/35/38.
14.) THIS SURVEY REMAINS THE PROPERTY OF MIXON LAND SURVEYING, INC.
15.) WRITTEN DIMENSIONS HAVE PRECEDENCE OVER SCALED DIMENSIONS.
SITE PLAN
NOT A
CERTIFIED TO:
JONATHAN C MODINE
ALYSSA F MODINE
UP =
WOOD UTILITY POLE
,� =
GUY ANCHOR
%- =
OVERHEAD UTILITY
K- =
FENCELINE
TV =
CABLE RISER
FH =
FIRE HYDRANT
PH =
PHONE
SS =
SEWER SERVICE
WM
= WATER METER
® =
WELL
WV
= WATER VALVE
(PR) =
PRO -RATED
D =
DEED
(P) =
PLAT
(M) =
MEASURED
(C) =
CALCULATED
ELEV.=
ELEVATION
BY:I REVISIONS:
POB =
POINT OF BEGINNING
POC =P0INT
OF COMMENCEMENT
ORB =
OFFICIAL RECORD BOOK
R =
RADIUS
L =
ARC LENGTH
A =
DELTA ANGLE
C/L =
CENTERLINE
R/W
= RIGHT OF WAY
D.E.
= DRAINAGE EASEMENT
U.E.
= UTILITY EASEMENT
= EXISTING ELEVATION
x0P
SO
= PROPOSED ELEVATION
TOB
= TOP OF BANK
21112 of y
St Lucie County Health Department
Environmental Health Division
Site Plan Approved for Construction
Supersedes AM Previous Site Plans for
OSTDS # m&Ls _ & Well #,z 2-/ 6&
Date:
BY: MIXON LAND SURVEYING, INC.
12450 NE 26TH AVENUE
OKEECHOBEE FLORIDA 34972
863 610 2200
STATE OF FLORIDA CERTIFICATE NO. "L.B. 4199"
EOW = EDGE OF WATER
CB = CATCH BASIN
MES = MITERED END SECTION
CMP = CORRUGATED METAL PIPE
RCP =REINFORCED CONCRETE -
PIPE
SMH = SEWER MANHOLE PR
DMH = DRAINAGE MANHOLE STATE OF
RICHARD A. MIXON
INAL SURVEYOR AND
A CERTIFICATE NO.
JOB NO. 14-062
CADD FILE:
14-062
BY: MARK MIXON
DATE:
t 7-15-14
3335" SHEET 1 OF 1